Vapour Jet Refrigerator / Heat Pump R853

Similar documents
Refrigeration Cycle Demonstration Unit R634

Refrigeration Cycle Demonstration Unit R633

P.A. Hilton Ltd. Figure 2: HC655A Optional Computer Linking Upgrade

Ventilation Trainer B500

Air & Water Heat Pump R832

Mechanical Heat Pump R515

Bench Top Cooling Tower H893

A660 Air Conditioning Laboratory Unit

SBS5311 HVACR II Experiment 2: Analysis of the Combined Rankine and Vapour Compression Cycle

THERMODYNAMICS STEAM P7690 AND STEAM BENCHES CUSSONS TECHNOLOGY LABORATORY RECOMMENDATION

3. (a) Explain the working of a rotary screw compressor. [10] (b) How the capacity control is achieved in refrigerant compressor?

ME 354 THERMODYNAMICS LAB THE REFRIGERATION CYCLE

Fig.: macroscopic kinetic energy is an organized form of energy and is much more useful

THERMAL ENGINEERING LABORATORY II. To train the students with principles and operation of thermal Engineering equipments.

cussons Refrigeration Assembly Range TECHNOLOGY REFRIGERATION AND AIR CONDITIONING CUSSONS TECHNOLOGY LABORATORY RECOMMENDATION

R10. IV B.Tech I Semester Regular/Supplementary Examinations, Nov/Dec REFRIGERATION & AIR-CONDITIONING (Mechanical Engineering)

Homework Chapter2. Homework Chapter3

International Journal of Engineering Research (IJOER) [Vol-1, Issue-3, June- 2015]

Refrigeration Technology in Building Services Engineering

R07. Answer any FIVE Questions All Questions carry equal marks *****

CHAPTER 7 PERFORMANCE ANALYSIS OF VAPOUR COMPRESSION REFRIGERATION SYSTEM IN HYBRID REFRIGERATION SYSTEM

Heat Transfer Service Unit H112

TITAN SERIES Complete Central Chiller & Pump Tank Package 20 to 70 Tons 20 F to 70 F

Department of Mechanical and Production Engineering Ahsanullah University of Science and Technology (AUST) Lab Manual on ME 4202

(Refer Slide Time: 00:00:40 min)

Performance analysis of ejector refrigeration system with environment friendly refrigerant driven by exhaust emission of automobile

Waste Heat Utilization of Vapor Compression Cycle for Operation of Vapor Absorption System

Dhulapally, Secunderabad Subject: REFRIGERATION AND AIR CONDITIONING QUESTION BANK

1 /35 2 /35 3 /30 Total /100

Cylinders for Domestic Purposes Heat Pumps

International Engineering Research Journal Performance Analysis of Ejector Based Solar Air Conditioning System

SIR C.R.REDDY COLLEGE OF ENGINEERING, ELURU DEPARTMENT OF MECHANICAL ENGINEERING ETD-II. Model Short Answer Questions And Answers

Brown Hills College of Engineering & Technology

IV SEMESTER DIPLOMA EXAMINATION, JANUARY-2013 THERMODYNAMICS

Chapter 9. Refrigeration and Liquefaction

LECTURE-17. Multi-Stage Vapour Compression Refrigeration. 1. Introduction

2. CURRICULUM. Sl. No.

MECHANICAL SCIENCE Module 2 Heat Exchangers

Performance Comparison of Ejector Expansion Refrigeration Cycle with Throttled Expansion Cycle Using R-170 as Refrigerant

Performance investigation of Air-conditioning system using ejector as expansion device

.2 Section Waste Management and Disposal.

LAB EQUIPMENT DETAILS

OFFICE OF THE PRINCIPAL GOVERNMENT ENGINEERING COLLEGE JAGDALPUR (C.G.)494005

A Review on Analysis of Vapour Compression Refrigeration System Using Matrix Heat Exchanger

THE ANALYSIS AND EXPERIMENTAL INVESTIGATION OF HEAT PUMP SYSTEM USING THERMOBANK AND COS EJECTOR CYCLE

LISTOF EXPERIMENTS. S. No. NAME OF EXPERIMENTS PAGE No.

Air Conditioning Clinic. Absorption Water Chillers One of the Equipment Series TRG-TRC011-EN

SAMPLE STUDY MATERIAL

REFRIGERATION AND AIR CONDITIONING

Homework #4 (group) Tuesday, 27 by 4:00 pm 5290 exercises (individual) Tuesday, 27 by 4:00 pm extra credit (individual) Tuesday, 27 by 4:00 pm

Presentation on HVAC: Heating Ventilation Air Conditioning

ENSC 388. Assignment #6

DTW Works Master Specification Version 2006 Issued 2006/08/01 Section15621 Packaged Reciprocating Water Chillers Page 1 of 5

SECTION HEATING BOILER FEEDWATER EQUIPMENT

PLEASE READ AND FOLLOW THESE INSTRUCTIONS

Chapter 8. Production of Power from Heat

Experienced Worker Assessment Blueprint HVAC - Heating, Ventilation and Air Conditioning

Analysis of Constant Pressure and Constant Area Mixing Ejector Expansion Refrigeration System using R-1270 as Refrigerant

SSC-JE STAFF SELECTION COMMISSION MECHANICAL ENGINEERING STUDY MATERIAL REFRIGERATION CYCLES REFRIGERATION CYCLES REFRIGERATION CYCLES

s. Properties for R134a are as follows : Saturated R-134a Superheated R-134a

SIDDHARTH GROUP OF INSTITUTIONS :: PUTTUR Siddharth Nagar, Narayanavanam Road AUTONOMOUS QUESTION BANK (DESCRIPTIVE) UNIT I

Experiment 2: Test on Domestic Refrigerator for evaluation of EER.

Product Data. Features/Benefits. 38AH Commercial Air-Cooled Condensing Units 50/60 Hz. 20 to 130 Nominal Tons (63 to 390 Nominal kw)

INSTITUTE OF AERONAUTICAL ENGINEERING

By: Prof K. M. Joshi,

Thermodynamic Calculations of Two-Stage Vapor Compression Refrigeration Cycle with Flash Chamber and Separate Vapor Mixing Intercooler

Jet Compressors. Circulate Steam Boost Low-Pressure Steam Compress and Mix Gases in Desired Proportion

Chapter 11 REFRIGERATION CYCLES. Department of Mechanical Engineering

Why Vaillant? Because the ecotec delivers day in, day out. Vaillant ecotec boiler range. The TECHNICAL Brochure

AC SYSTEM CONFIGURATION- CENTRAL CHILLER PLANT

COOPERATIVE PATENT CLASSIFICATION

Steam Generator (Boiler) & Steam Turbine. Steam Generator (Boiler) ME 268. Model Lab

Refrigeration Cycles MOHAMMAD FAISAL HAIDER. Bangladesh University of Engineering and Technology

Chapter 10 VAPOR AND COMBINED POWER CYCLES

armfield COMPUTER CONTROLLED HEAT EXCHANGER SERVICE MODULE HT30XC series issue 2

BASE LEVEL AUDIT REQUIREMENTS REFRIGERATION SYSTEMS 1. SITE DATA COLLECTION. Business Name. Site physical address (Street, Suburb, City)

TMCI Padovan Evaporators

PERFORMANCE OF VCRS SYSTEM WITH HEAT EXCHANGER AND PHASE CHANGE MATERIAL

Conceptual Design of a Better Heat Pump Compressor for Northern Climates

Vicot Air Conditioning Co., Ltd. CONTENT

PERFORMANCE EVALUATION OF CO 2 HEAT PUMP HEATING SYSTEM ABSTRACT 1. INTRODUCTION

Plumber Level 3 Rev. May 2011

Engineering Thermodynamics. Chapter 7

ASSSIGNMENT 3. Textbook Assignment: Boilers, chapter 4, pages 4-1 through 4-15, and Steam Turbines, chapter 5, pages 5-1 through 5-1.

Evaporative Cooling. HEVAC Association. Humidity Group. an alternative and supplement to mechanical cooling

(a) (i) Through which part of the house is most heat lost? How can the heat loss through the windows be reduced? ...

Energy Efficiency Through Waste Heat Recovery. Heat Recovery Centrifugal Chillers and Templifier Water Heaters

Performance Assessment of Water Cooled Condenser Refrigeration System

College of Technological Studies Department of Power & Refrigeration Technology. Course Contents

EBAC MODEL K100 DEHUMIDIFIER OWNER S MANUAL

Transcritical CO2 Bottle Cooler Development

Math. The latent heat of fusion for water is 144 BTU s Per Lb. The latent heat of vaporization for water is 970 Btu s per Lb.

REFRIGERATION TUTOR. OBJECTIVE: To perform test on the refrigeration tutor to determine different COPs and other performance parameters.

ME 410 MECHANICAL ENGINEERING SYSTEMS LABORATORY MASS & ENERGY BALANCES IN PSYCHROMETRIC PROCESSES EXPERIMENT 3

MAXIMUM SERIES. Maximum Series portable chillers can be used on a variety of process applications that require 20 F to 70 F chilled water.

Appendix A. Glossary of Common Terms

EXPERIMENTAL INVESTIGATION OF COMPARISION OF AIR COOLED AND WATER COOLED CONDENSER ATTACHED WITH COOLING TOWER

Intermediate Refrigeration Systems for Operators

Performance of R-22, R-407C and R-410A at Constant Cooling Capacity in a 10

ENERGY SAVINGS THROUGH LIQUID PRESSURE AMPLIFICATION IN A DAIRY PLANT REFRIGERATION SYSTEM. A. Hadawey, Y. T. Ge, S. A. Tassou

Transcription:

Vapour Jet Refrigerator / Heat Pump R853 Enables demonstration and investigation of the combined Rankine and Vapour Compression Cycle Is an example of a refrigerator or heat pump driven by a Heat Input as opposed to the more usual work input Uses hot water as the high grade heat source, thus limiting the maximum temperature to 100 o C Evaporation and Condensation may clearly be seen through glass cylinders As a heat pump, the unit shows approximately the same primary energy ratio as a work-driven heat pump All important components are mounted on the front panel and quickly responds to a change in operating conditions. Optional Solar Panels available Two Year Warranty Page 1 of 5

Introduction Refrigerators and Heat Pumps are machines which extract heat from a low temperature region and reject heat to a region at a higher temperature. If the prime function of the machine is to extract heat from low temperature region, the machine is a REFRIGERATOR. Conversely, if the prime function is to deliver heat at a useful temperature, the machine is a HEAT PUMP. The Laws of Thermodynamics indicate that the transfer of heat from a cold to a hot body is impossible without the aid of external assistance, i.e. a high grade energy input. This input can be in the form of a WORK TRANSFER or of a HEAT TRANSFER AT A HIGH TEMPERATURE. Since work is the most valuable form of energy, the quantity of work required for a given heat transfer from a cold to a hot body, will be less than if a high grade heat input is employed. However, work is usually derived from a very high grade heat input in a Thermal Power Station or other Prime-Mover. As the thermal efficiency of these is usually between 25 and 35% there can be an overall advantage in using a heat input to drive a heat pump or refrigerator. The Combined Rankine and Vapour Compression Cycle. The pressing need to conserve fossil fuels has aroused interest in two distinct possibilities associated with refrigeration: a) Refrigerators which will operate from non-fuel consuming input (e.g. solar radiation, waste heat, geothermal heat). b) Combined prime movers and heat pumps which burn fuels, but which make more heat available for intermediate grade heating purposes than was available from the fuel consumed. The Combined Rankine and Vapour Compression Cycle makes both of these possible. In a Combined Rankine and Vapour Compression Cycle, a high grade heat input generates high pressure vapour in a boiler. This vapour expands in a turbine producing work, and then passes into a condenser where it is liquified by rejecting heat. The liquid is then pumped back into the boiler for re-evaporation. The work produced by the turbine drives a conventional vapour compression cycle refrigerator or heat pump. Assuming that the same fluid is used throughout, the turbine and compressor can discharge into a common condenser. Neglecting heat losses, it will be seen that the ratio Intermediate Grade Heat Delivered = Q H + Q L is greater than unity Q High Grade Heat Input H The effectiveness of the combined Rankine and Vapour Compression Cycle depends upon the temperatures at which, i. heat is supplied at the boiler, ii. heat is available to the evaporator, iii. heat is rejected at the condenser, iv. The efficiency of the expansion and compression processes. The unit will be a valuable teaching aid for students of: Refrigeration & Air Conditioning Building Services Mechanical Engineering Plant and Process Engineering Energy Conservation Energy Management Chemical Engineering Food Technology Marine Engineering Agriculture Engineering Page 2 of 5

Experimental Capabilities The following experiments can be performed: Analysis of the combined Rankine and Vapour Compression Cycle. Demonstration of the characteristics of an ejector or thermo compressor. Production of performance curves as a refrigerator and comparison with ideal o Rankine/Vapour Compression cycle. Production of performance curves as a heat pump and comparison with ideal o Rankine/Vapour Compression Cycle. Investigation of entrainment mass ratio at various pressures. Demonstration of adiabatic mixing of hot and cold vapour. Demonstration of adiabatic throttling. Description The unit may be regarded as a combined heat engine and a refrigerator/heat pump. The system powering the refrigerator/heat pump works on the well-known Rankine cycle (frequently used in steam power plants.) In this cycle the unit takes in heat at a very modest temperature (about 90 o C) and rejects heat at the condenser temperature (about 30 o C). The work output of this engine is in the form of the kinetic energy of a jet instead of shaft work as is normal with a Rankine cycle. The refrigerator/heat pump operates on the Vapour Compression Cycle and uses the output of the Rankine Cycle (i.e. the kinetic energy of the jet). It takes in heat at a low temperature in an evaporator and rejects heat at a higher temperature using the same condenser as the engine. Both the Rankine Power Plant Cycle and the Vapour Compression/Heat Pump Cycle are included in most courses of study for young engineers. The Hilton Vapour Jet Refrigerator/Heat Pump R853 demonstrates practically, the potential of combining these cycles so that a heat pump or refrigerator can be run from a heat output. Controls and operation The unit has three simple controls: 1. Condenser cooling water flow rate this, in conjunction with the inlet temperature of the cooling water, determines the temperature and pressure in the condenser, and thus the temperature at which heat is rejected. 2. A variable transformer this varies the heat input to the electric heater in the evaporator, which in turn controls the evaporation temperature. A voltmeter and ammeter indicates the energy input to the heater. 3. A manually adjustable throttle valve this is placed between the vapour generator and the nozzle and enables the unit to be operated below the maximum pressure. Instrumentation is provided for temperature and pressure measurement, the heat input to the evaporator and the water flow rate. The mass flow rates of the refrigerant at the evaporator can be readily obtained from the measured energy transfer rates and the enthalpy changes. The heat transfer at the refrigerant vapour generator is obtained by the difference between the heat transfer at the condenser and that at the evaporator and the heat transfer rate to or from the surroundings. It should be noted that the performance of all vapour power plants, refrigerators and heat pumps falls as the condenser temperature rises. This is true of the Vapour Jet Refrigerator/Heat Pump and it is recommended that, if a useful range of test conditions is to be investigated, the condenser cooling water temperature should not exceed 22 o C. Page 3 of 5

Optional Solar Panels and Installation Package F821S The R853 Vapour Jet Refrigerator/Heat Pump may be run from any source of hot water at a sufficiently high temperature, i.e. about 90 o C. In locations where conditions are suitable, the F821S Solar Panels & Installation Kit enables these units to be run from hot water generated in solar panels. The kit, which is for on-site assembly and installation, includes the solar panels and all the components required for connection to the unions provided on these units. Specification Panel: High quality glass reinforced plastic on which the following are mounted: Steam Generator: Rectangular glass reinforced plastic insulated vessel fitted with 1.5kW immersion heater and containing the refrigerant vapour generator. Refrigerant Vapour Generator: Cylindrical stainless steel shell, 75mm dia x 200mm long, with dished ends fitted with sight glass and pre-heating coil. Ejector Nozzle: Convergent-divergent, throat diameter 1.7mm. Compressor: Diffuser: With combining cone, parallel and divergent portions. Evaporator: Thick walled glass cylinder fitted with metal end plates and P.T.F.E seals. Evaporator incorporating a 500W heater controlled by a variable transformer and a float type expansion valve. Condenser: Thick walled glass cylinder fitted with water cooling coil. Surface area of coil: 0.1m 2. Feed Pump: Reciprocating plunger type pump fitted with P.T.F.E. seals and water jacket, driven by electric motor through worm reduction gearbox to give approximately 60 double strokes / minute. Instrumentation Thermometer: Digital type K electronic thermometer with 0.1 o C resolution and 12 way selector connected to 9 thermocouples to measure all important temperatures. Pressure Gauges: Two 0 to 800 knm-2 to indicate refrigerant vapour generator and nozzle inlet pressure. Two 100 to + 100 knm-2 to indicate evaporator and condenser pressure. Flow Meter: Variable area glass tube type fitted with control valve to measure water flow rate through condenser. Range 0 to 75g s -1. Voltmeter and Ammeter: To measure power input to evaporator. Ranges 0 to 250Vand 0 to 3A respectively. Safety features Pressure Relief Valves: Fitted to vapour generator, evaporator and condenser. High Pressure Cut Out Fitted to vapour generator and condenser. Switches: Low Water Flow Switch: To switch off power supply if insufficient water flows through the condenser. Solenoid Valve: To isolate vapour generator from ejector, evaporator and condenser. High Temperature Cut Out: Fitted to all heater elements. All circuits are protected by a fuse. Dimensions Height: 92.5cm Depth: 43.0cm Width: 106cm Weight: 102kg Accessories and Spares Unit supplied with: One experimental operating and maintenance manual in English, Spanish or French. Accessories and spares for 2 years normal operation. List available on request. Throttle Valve: Manually adjustable to vary nozzle inlet pressure. Page 4 of 5

Services Required Electrical: A: 2.5kW, 220-240 Volts Single Phase 50Hz(With earth/ground). B: 2.5kW, 110-125 Volts Single Phase, 60Hz (With earth/ground). Water: 250 litres / hour at 15m head. Water temperature should not exceed 22 o C if a useful range of test conditions are to be investigated. Ordering Information Order as : R853 Vapour Jet Refrigeration/Heat Pump Optional: F821S Solar Panels and Installation Package Language Either: English, Spanish or French. Shipping Specifications Net Weight: 102kg. (approx.) Gross Weight: 190kg. (approx.) Packing Case Dim: 1.25 x 0.622 x 1.194m (approx) Packing Case Volume: 0.928m3 (approx.) Also Available On Request Further detailed specification. Additional copies of instruction manual. Recommended list of spares for 5 years operation. Suitable chiller details. Optional F821S Solar Panels and Installation Kit The solar panels are of the flat plate type with a selective finish, housed in a durable aluminum casing. The rear face of the panel is well insulated with rockwool and the front face is protected by an air gap and a special plastic film having a higher transmission than glass. To reduce heat losses and wind loads, the panels should be mounted in a sunny sheltered position so that, at noon, the face of the panel receives solar radiation normally. The panels should be as close as possible to the connected unit (12m maximum) and if possible at a higher level to assist venting. Screens are provided on the panels and these must be closed when the panels are not in use. Water connections between the panels and unit are via annealed copper tubes which are insulated during assembly. The water is pressurized to 200kN m -2 g by a pressurised air cushion in an expansion vessel and an automatic vent discharges air from the highest point. A water meter and thermocouples (for connection to the unit instrument panel) enable the heat collection rate to be measured. P.A.HILTON Ltd. Horsebridge Mill, King s Somborne, Stockbridge, Hampshire, SO20 6PX, England. Telephone: National (01794) 388382 International +44 1794 388382 Fax: National (01794) 388129 International +44 1794 388129 E-mail: Website: sales@p-a-hilton.co.uk www.p-a-hilton.co.uk Page 5 of 5