HSD Dry Cabinet

Similar documents
HSD Dry Cabinet. Outstanding performance

HSD Dry Cabinet. Outstanding performance

XSD Dry Cabinet

Long Term Storage Cabinet

MSD Cabinets. Modular Dry Cabinet. Outstanding performance

SD Storage Cabinet. Outstanding performance

SD Storage Cabinet. Outstanding performance

XSD Dry Cabinet. Outstanding performance. The XSD series has an outstanding performance for drying moisture sensitive components and pcb s.

SDR Dry Room. Outstanding performance

SD Storage Cabinet

XSD Dry Cabinet

SDB Storage Cabinet

XSD Dry Cabinet

Drying Cabinets and Vacuum Machines for Moisture Sensitive Components

Drying Cabinets and Vacuum Machines for Moisture Sensitive Components

A Member of the ASYS Group A Member of the ASYS Group PRODUCT CATALOGUE

Revolution of Low Humidity Storage!!

Constant climate chambers

Constant climate chambers. KBF 240 (E5.2) - Constant climate chamber. Performance features and equipment:

Revolution of Low Humudity Storage!!

Model MKFT 115 Dynamic climate chambers for rapid temperature changes with humidity control and extended low temperature range

Environmental simulation chamber for complex alternating climate profiles

Laboratory Air circulated Refrigerator/Deep Freezer TC Two-door (2 independent temperature ranges)

Drying and heating chambers

Constant climate chamber with humidity

INSTRUCTION MANUAL ESDA Cabinets with display

Constant climate chamber with ICH-compliant illumination

METAL SHARK COMBI Flat metal detector for textile and non-woven products. Metal sensitivity from Fe 0,3 mm

ULTRA-LOW HUMIDITY STORAGE CABINETS 1, 3%RH

Constant climate chambers

portable gas analyser

CLIMATIC TEST CHAMBER CTC / TEMPERATURE TEST CHAMBER TTC 100 % AtmoSAFE: In Memmert environmental

KMF Environmental test chamber for constant climate

ULTRA-LOW HUMIDITY SEIKA. ERC Co., Ltd. ULTRA-LOW HUMIDITY STORAGE CABINETS 1%RH. Conforms to IPC/JEDEC J-STD-033D and IPC-1601 Guidelines.

Compressed air quality meas. according to ISO 8573 Residual oil content - particles - moisture

Model MKFT 115 Dynamic climate chambers for rapid temperature changes with humidity control and extended low temperature range

Laboratory Deep Freeze Storage Cabinet TC 230 Air circulated

Dew point set DS 400

Technical Description. Laboratory Climate Test Chamber. System Weiss. Mat. No.: Type WKL 34/40

Constant climate chambers

Constant climate chambers

Medical Air circulated Refrigerator TC (2 independent temperature ranges), also in accordance with DIN 58345

Mercury Vapor Monitor VM-3000

Plasma Freezer with air circulation TC 516 acc. to DIN 58375

Specifications Minimum Typical Maximum Unit

Chromatographic Air circulated Refrigerator, two-door TC 603

EST User Manual. (Please read this manual carefully before using)

VM-3000 Mercury Vapor Monitor

573 Dew Point Mirror. Industrial Chilled Mirror Hygrometer. Typical applications:

Constant climate chambers

Ultra low temperature freezers for long-term storage at -86 C UF V 500, UF V 700

External Dimensions: B = 600 mm D = 630 mm H = 2000 mm. Internal Dimensions: B = 451 mm D = 430 mm H = 1598 mm

External Dimensions: B = 750 mm D = 700 mm H = 2100 mm. Internal Dimensions: B = 600 mm D = 580 mm H = 1270 mm. Temperaturerange: 2 C to 20 C

Operation Manual for Drying Storage Cabinet with Drying Unit U-5002

NEW GENERATION. Efficient use of valuable space INCUBATORS

Climate chambers with illumination and humidity The BINDER KBWF series shines with its

Dew point. Special features: Dew point monitoring DS 400. Technical data DS 400. Technical data FA 510

DP 300 mobile dew point instrument

Walk in Steam Curing Chamber for Concrete Application. Detailed Working Specifications

FITOCLIMA 600 & 1200 STABILITY

Motion Sensor. For Outdoor Use. Wall & ceiling mounted. Quick & Easy Installation 2 Channels

SA-3841 User Manuel. 1U 4 Fans Unit with Thermostat Sensor. Version 1.1 Copyright All Rights Reserved

Plant growth chambers

THX-DL Data Logger USER & INSTALLATION MANUAL V

973 Dew Point Mirror. Portable Industrial Chilled Mirror Hygrometer. Typical applications: REFLECTING YOUR STANDARDS

PRESENTATION OVERVIEW OF THE DIFFERENT MODELS MONITORS

Instruction Manual heater SH for SD dry cabinets

Huminator II. Precision Humidity Generator. ww.testo.in

Termaks AS Lien 79, N-5057 Bergen, Norway Tel: Fax: Web:

Constant climate chambers


DFM. flow pressure temperature MULTI PARAMETER DIGITAL MASS FLOW METERS. Totalizer. Interface

Chromatographic Air circulated Refrigerator, two-door TC 603

Laboratory Refrigerator/Deep Freezer TC 802

Dew Point Mirror 373. High Precision. Fast Response. Wide Measuring Range. Laboratory Reference. Touch Screen. Full Color High Resolution LCD

Drying and heating chambers. Series ED FD FED FP M

Constant climate chambers

Automatic Isokinetic Sampler ST5

Accessories, interfaces, sensors and complete solutions.

Model C 170 CO 2 incubators with hot air sterilization

EC 160 CO 2. Incubator

Inductive. Range. S410/IND Electrodeless Conductivity Sensors

FITOCLIMA 600 & 1200 STABILITY

Model CB 220 CO 2 incubators with hot air sterilization and heat sterilizable CO 2 sensor

CO₂ incubators. C CB series

New Generation KBF 240 series

STABILITY. Stability Storage Chambers & Environmental Stability Rooms

Infrared Moisture Balance (FD-800)

Standard-Incubators. Avantgarde.Line BD BF series. Classic.Line B BD BF series. Solid.Line BD-S series

HUM-M2 Humidity Sensor Module Description

IMR 5000 Operating Manual S/N: SAMPLE For information only! IMR Environmental Equipment Inc.

Model KBF 240 Constant climate chambers with large temperature / humidity range

Refrigerated Incubators / Environmental Testing Chambers

EMS510 PS-1 COMPLIANT OPACITY/DUST MONITOR

VM-3000 Mercury Vapor Monitor

ULTRA-LOW HUMIDITY STORAGE CABINETS 1, 3%RH

Portable Alpha/Beta Continuous Online Air Monitor (CAM)

Future Blast Chiller and Blast Chiller/Freezer cabinets

PANELS, KEYPADS & MODULES. Take Fire Protection to the Next Level Fire Products from DSC

Background. Totech dry cabinet

Transcription:

HSD 1106-52 Dry Cabinet Outstanding performance fast recovery time The HSD cabinet series has an outstanding performance for drying moisture sensitive components and pcb s as a result of a high performance drying unit. Therefore it is very suitable for operation with frequent approach. The dynamic drying unit of the 5000 series reaches very reliable low humidity values of 0,5% RH and automatically regenerates if necessary. Humidity, temperature and alarm functions are shown and can be adjusted on a digital display.

Features ESD safe design Lockable doors Data logging Online functionality Door & humidity alarm buzzer Lockable doors Transport Shelves U 5000 series drying unit Accuracy of sensor RH% & T C Power supply Norm (IEC 61340-5-1) ESD metal painted body (10 6 Ohm/sq) Dissipative glazing (in- and outside 10 8 Ohm/sq) 6 doors, locked with key Integrated data logger over sensor with standard 2000 measuring points (optional software is required) Interface and data logging through standard Ethernet interface Compatible with new MSL 2.0 software Longer door openings are detected, high RH levels are detected Every door can be locked separately with a key Castors 5 in height adjustable chrome steel shelves 0.5% RH, made in Germany Precision sensor, accuracy +/- 0,8 % RH, +/- 0,3 C Power cord 5 meter with IEC plug Benefits Recovery time after door opening Energy saving consumption% & T C Network IPC European Quality Maintenance < 6 minutes to below 1% (with 1 door opening) Average power consumption of 46 W/h Standard ethernet interface According to IPC/JEDEC J- STD 033C & IPC-1601 Made in Germany Easy to service, low maintenance

Technical Data Cabinet External dimensions: (W x H x D) 1200 x 1675(1840) x 658(768) mm Internal dimensions: (WxHxD) 1190 x 1533 x 630 mm Weight: 189 kg Weight on shelf: 50 kg Max. loading 300 kg capacity: Body: Steel, conductive coated 10 6-10 8 Ω/sq Shelves (W x D): 5 pcs, 1150 x 490 mm adjustable Volume: 1179 L Voltage: 230 V AC (120 V AC optional) Power consumption: 46 W/h (excl. heater) Protection class: hard grounded, Class 1 Humidity level 0,5 % RH cabinet: Sensor Accuracy: ± 0,8 % RH, ± 0,3 C Technical Data 52 Display Settings: Language Menu Nominal Value Humidity Nominal Value Humidity Alarm Delay Humidity Alarm (in combination with heater) Nominal Value Temperature (in combination with heater) Temperature Alarm (in combination with heater) Delay Temperature Alarm Doors Alarm Interlocking Manual Regeneration Display: Supply voltage (supplied by drying unit) 24 VAC/DC Input 4 function keys (tactile-touch keys) Display 61 x 33 mm, white, controllable backlight, adjustable contrast Ethernet connection Power consumption at 24VDC, 40mA

Technical Data Rotronic Sensor HC2-S Based on the Airchip 3000 Technology use the HygroClip 2 probes can be used for control of temperature and humidity. The HygroClip 2 probes can be configured with the ROTRONIC HW4 software and share the following features: Measurement of relative humidity and temperature. Data recording of up to 2000 relative humidity and temperature value pairs. Programmable automatic sensor test with fail safe mode and sensor drift compensation. Technical Data dry-unit U 5000 series Dehumidifying performance: 120 g/h max. Minimal humidity 0,2% RH Dehumidifying Temperature 10 60 C Electric supply: 230 VAC (120 VAC available) Dimensions (L x B x H): 487 x 487 x 150 mm Weight: 21 kg

Technical Data Heater SH-230-4 Voltage: 230 V AC (110 V AC optional) Frequency AC: 50/60 Hz Power: 780 W Temperature sensor: PTC 100 Thermal protection: 90 C Temperature range: 30 40 C Air Flow: 86 M 3 /H Display tolerance: 1 digit at 25 C Technical Data N 2 (Auto) Flow Power supply: 90-240 V AC (110 V AC optional) N 2 Connection: 8 mm hose connection N 2 Pressure: 1 6 bar N 2 Standby- amount: 0 25 L/min N 2 Purge: 0 100 L/min (Purge-Time): 0 99 min

Performance test Test conditions Instrument: Vaisala. Type of dew point sensor: Vaisala drycap 180M Accuracy of dew point sensor: ± 0,2 C at + 20 C (+ 68 F) Location of sensor: In the direct surrounding of cabinet sensor Ambient conditions: Humidity 50 ± 5% rh, 25 ± 2 C, Pressure 994 ± 20 hpa. Dooropenings: 2 dooropenings, 15 sec. (average RH 0,70%)

Technical Technical Drawings Drawings Dimensions mentioned in mm. HSD 1106-52 HSD 1106-52 Number of shelves bottom section 2 3 4 5 Distance (in mm) between shelves if equally divided in bottom section 350 230 175 125 Remaining space between top shelf and middle beam 370 225 125 120 Remaining space between bottom shelf and bottom cabinet 330 230 180 125 Loading capacity shelves m 2 (1155 mm x 490 mm) 1,13 1,70 2,26 2,83 Number of shelves top section 2 3 4 5 Distance (in mm) between shelves if equally divided (if bottom shelf is mounted at lowest possible position in top section) 350 230 175 125 Remaining space between top shelf and top beam 370 230 125 125 Remaining space between bottom shelf and middle beam 330 230 180 130 Loading capacity shelves m 2 (1155 mm x 490 mm) 1,13 1,70 2,26 2,83 Shelves are adjustable every mm 50 50 50 50 Measurements can slightly deviate. Note: Calculations measured from the bottem shelfs (each section) on the lowest possible position.

Technical Drawings Dimensions of the SMD Reel Rack, item number 20014000 Dimensions of the Heater SH 230-4, item number 21001001

Free Totech viewer: Writing of climate data, door openings and alarms to SD card Transfer of data through Ethernet to PC (history data) User-friendly display of all relevant data Data processing in MS-Excel Seamless documentation Excellent process safety

Options N2 auto flow system, The Auto-Flow-System is developed to use in combination with a Totech drying cabinet. The device is used for the quick removal of moisture in the cabinet after the doors has been opened. The drying process is realized by using nitrogen (N²), which is add automatically after the doors have been closed. (by means of adjustable timer function). Item number 22613000. N2 flow system, The Flow-System is developed to use in combination with a Totech drying cabinet. The device is used for adding nitrogen (N²). Item number 20010020 SMD Reel rack ESD coated with reel supports, Item number: 20014000 Reel support, additional reel supports for 20014000: Item number: 20014200 Humdidity alarm signal Lamp, two-color, (orange/green), magnetically fixed, providing optical signals on operational states and exceeded limit values. Operates on 24 V. Item number: 20016030 Humidity calibrator Hygropalm 22, precision measuring device for calibrating sensors Set including Hygroclip sensor, case and cable Item number 20001019 Hygropalm only Item number 20001016

Options MSL 2.0 software for 1000 components, Software solution for the monitoring of moisture sensitive components and their MSL States during storage and processing in the production. With the software the exact drying state individually for each component is monitored and displayed. One of the possibilities is that it can read out multiple HC2-S sensors. To adjust storage conditions,picking of stock, removal of used parts & more stock control. Here, a complete history for each component is traceable up to the full processing. The evaluation of the drying conditions is based on the requirements of the IPC / JEDEC J-STD-033C directive. Item number 20010036 MSL software upgrade with additional 1000 components, Upgrade to monitor an additional 1000 components Item number 20010037 Totech Monitor software Real time cabinet monitoring with alarm function, sending emails with detailed information on the status of the cabinet. History data files with graphical overview Item number 47000583 Rotronic datalogger set, Including Software HW4-E-V3 and Cable AC3006 Item number 47000580 Sensor accuracy: +/- 0,8 % RH, +/- 0,3 C HSD internal led light 2 x internal LED light for convenient view of internal parts Item number 47005391

Options Shelf standard, For cabinets type 1106 and 1104. Item number 20111409 Brackets 2 pcs, item number 20111709 Shelf, For cabinets with 2 drying units. Item number 20111609 Brackets 2 pcs, item number 20111709 Heater SH 230-4, 40 C heater Item number 21001001 Adjustable legs 4 in height adjustable legs (63 80 mm). Item number 20010010