Genesis Series Cable THE POWER OF CHOICE. Cables for Silent Knight

Similar documents
Fire Alarm Cables. Features: Countdown. New Labeling System on box. Color Coded Boxes. Zone and Room Markings

Honeywell Cable. We ve got a cable for that!

Fire Alarm Systems ARTICLE. Introduction to Article 760 Fire Alarm Systems. Part I. General

Honeywell Cable & Custom Electronics

Product Guide. Fire Alarm Cables. Initiating Device, SLC Lines, and NAC Cables.

Genesis Cable Audio/Video Product Catalog DELIVERING THE ULTIMATE AUDIO/VIDEO EXPERIENCE

Genesis. Series Low Voltage Cable. Honeywell Cable Catalog

Genesis Cable Audio/Video Product Catalog DELIVERING THE ULTIMATE AUDIO/VIDEO EXPERIENCE

SIGA-CC1 Single Input Signal Module Installation Sheet

I dedicate this book to the Lord Jesus Christ, my mentor and teacher. Proverbs 16:3 NOTICE TO THE READER ABOUT THE AUTHOR

Silent Knight Software Suite Intelliknight Training

Print Specification. Publication. Instructions. Specific requirements. General requirements

WIRE & CABLE. Wire & Cable... Wire Accessories...

PAIRED UNJACKETED. Insulation Nominal Anixter. Paired Conductors Thickness O.D. Number AWG Strand No. IN IN

Addressable NAC Output Module D327A

Fire Alarm/Life Safety Cable 6

ARTICLE 760 FIRE ALARM SYSTEMS

IDP-Zone-6 Six Zone Interface Module

WIRE & CABLE. Wire & Cable... Wire Accessories...

Fire alarm system specification for multiple tenant retail buildings

Security & Control Cables

1. Floor above/floor below notification. 2. Private alarm notification. 3. Not Used 4. Voice alarm notification. 5. Not Used.

Intelligent Analog/Addressable Fire Alarm/Voice Integration Systems. IntelliKnight TM Series

NFPA Changes

SECTION DIGITAL, ADDRESSABLE FIRE-ALARM SYSTEM

Booster Power Supply Manual

Fire Alarm System Fundamentals

Multiple Input and Output Modules

NewGeneration Cables. BELDENCable TM

Comtran s VITALink 2 Hour Fire Resistive CIC & CI Free Air Cables. Your trusted solution for fire safety

ACC-25/50ZST. Zoned System Voice with Telephone Evacuation Control Panel

IFP-2000 F r a en e h n y h t y PH P D

2. HVAC and smoke control systems; fire, smoke, and combination fire/smoke dampers. 5. Central control and monitoring system.

SC-6 Six Supervised Control Module

PART IV DETAILED SPECIFICATION

good things in small packages

Home Theater Cables. Your complete solution for high-end audio transmission, stereo, professional audio systems and home theater systems.

CZ-6A Six Zone Interface Module

MMF Six Zone Interface Module

Signature Series Auto-Sync Output Module (CC1S)

Concerns: Affects: Dated: June 12, SECTION 1: GENERAL Scope Work Included... 3

TABLE OF CONTENTS GENERAL... 2 A. DEFINITIONS DIGITAL, ADDRESSABLE FIRE ALARM SYSTEM... 2

SECTION : FIRE ALARM & DETECTION SYSTEMS

SECTION FIRE ALARM SYSTEMS

/5121/5122 TrueAlert Power Supply Installation Instructions

Full Service Central Station Fire Alarm Listing Evaluation

Advanced Fire Alarm Systems Training Program Outline (5 Day)

electronic wire pocket-picker edition 7/06 Low voltage electronic wire specialists

Fire Alarm Control Systems

Surviving Survivability A User s Guide to Survivable Fire Alarm Circuits Larry D. Rietz, SET 23 May 2018

Fire Alarm Wiring. Circuit types, styles and limitations

Quick Reference Applications Guide

Case Study Media Contact Beth Welch, or

PART 1 GENERAL Quality Assurance A. Fire Alarm Contractor Qualifications:

16721 FIRE ALARM AND DETECTION SYSTEMS

Installation and Operation Guide. EVS-Series. Emergency Voice System. Document: LS SK-E ECN:

Honeywell Combination Fire & Burglary Control Panel

PHYSICAL FACILITIES Consultant s Handbook Specifications Division 28 Electronic Safety and Security 4600 Fire Detection and Alarm

Multi-Application Peripherals and Accessories

SECTION FIRE ALARM STANDARDS REVISED CONSTRUCTION STANDARD

SOUND/SECURITY FIRE ALARM/LIFE SAFETY TEMPERATURE CONTROLS COAXIAL DATACOM HARDWARE FIBER OPTIC SPECIAL APPLICATION CATALOG, VOL.

Valuation: # of Plans Submitted: # of pages: Type of Work (select one): New Addition Existing System/Modification Project Name: Scope of Work:

16721 FIRE ALARM AND DETECTION SYSTEMS

Session: Fire Alarm Installation

PROTECTED PROPERTY. City: State: Zip Code: ALARM SERVICE COMPANY. City: State: Zip Code: COMMENTS AND CLARIFICATIONS ALARM SYSTEM DESCRIPTION

1.3 REFERENCE STANDARDS

Pompano Pet Lodge 930 Northwest 31 st Avenue Pompano Beach, FL 33069

Company Profile. We are dedicated to providing our customers competitive price and excellent service.

INSTALLATION MANUAL: IDC-6 INITIATING DEVICE CIRCUIT EXPANDER

WINDOW & HVAC REPLACEMENT PEMBERTON TOWNSHIP BOE REGAN YOUNG ENGLAND BUTERA, PC PROJECT #5450E

OSU PROJECT NO PAGE 1 02 NOV 2006 SECTION FIRE ALARM SYSTEM

Fire Alarm Control Systems Simple. Smart. Reliable.

TrueAlert Addressable Notification

Idaho Surveying & Rating Bureau, Inc South Cobalt Point Way Tel: (208) Meridian, Idaho FAX: (208)

Mircom FX /01/16

PART 1 GENERAL Quality Assurance A. Fire Alarm Contractor Qualifications:

NETWORK FIRE ALARM CONTROL PANEL. Features

IntelliKnight 5820XL Addressable Fire Alarm Control System Sales Guide

E-PDD Duct Smoke Detector Installation Sheet

Rev. B. TrueAlert Addressable Controller Application Manual

FireNET Plus Wiring Instructions

SECTION FIRE ALARM INTEGRATED AUDIO VISUAL EMERGENCY COMMUNICATION SYSTEM

Alarm & Security SOLUTIONS. Access Control Video Surveillance Fire Alarm Life Safety

FIRE ALARM AND DETECTION SYSTEMS

Hinesville First United Methodist Church SECTION DIGITAL, ADDRESSABLE FIRE-ALARM SYSTEM

4007ES Fire Control Panels

4007ES Fire Control Panels

MODEL IFP-100. Installation and Operations Manual. Analog/Addressable Fire Control Panel. Part Number Rev L

OKLAHOMA STATE UNIVERSITY

Unified Fire Authority - Fire Prevention Bureau

SILENT KNIGHT IFP-1000

Brighton Area Fire Authority

FARENHYT ORDER FORM Page 1 of 5

4007ES Fire Control Panels

SECTION COMMON WORK RESULTS FOR ELECTRONIC LIFE SAFETY AND SECURITY

ADVANCED TECHNOLOGY, FLEXIBILITY, AND BUILT-IN SURVIVABILITY

MODEL IFP-2000/ RPS-2000

PROJECT: IIT MADRAS RESEARCH PARK-CHENNAI, TECHNICAL SPECIFICATION FOR FIRE ALARM SYSTEM TENDER

University Design Standard Fire Alarm Systems

WHEA FSE inspections.

Transcription:

Genesis Series Cable THE POWER OF CHOICE Cables for Silent Knight

Cable for That! Genesis Series Cables for Silent Knight 5600 5700 5808 5820XL IFP-25 IFP-50 IFP-100 IFP-1000 IFP-2000 SK-5208 DIRECTORY SBUS... 2 Signaling Line Circuits (SLC)... 3 Conventional 2&4 Wire Initiating Device Circuits (I)... 4 Notification Appliance Circuits (NAC)... 4 Emergency Communication System Panels... 5 Honeywell Genesis Series Fire Alarm Cables... 6 NEC Article 760 Fire Alarm Systems The scope of this article covers: Installation of wiring and equipment of fire alarm systems, including all circuits controlled and powered by the fire alarm system. Also includes fire detection and alarm notification, guard's tour, sprinkler waterflow and sprinkler supervisory systems. Circuits controlled and powered by the fire alarm system, including circuits for the control of a building system s safety functions, elevator capture, elevator shutdown, door release, smoke doors and damper control, fire doors and damper control and fan shutdown, but only where these circuits are powered and controlled by the fire alarm system. NEC Listings for Power Limited Fire Alarm (PLFA) cables FPL: For general use in buildings FPLR: For use within buildings in vertical shafts FPLP: For use in ducts, plenums or other environmental spaces Direct Burial: For use outdoor or underground sunlight resistant 2

SBUS 5600 5700 5808 5820XL IFP-25 IFP-50 IFP-100 IFP-1000 IFP-2000 SK-5208 22-14, 4 Solid Copper Conductors, Unshielded Total Worst Case Current Genesis Series Cables 0.1 A 0.2 A 0.3 A 0.4 A 0.5 A 0.6 A 0.7 A 0.8 A 0.9 A 1.0 A General Riser Plenum ft. m ft. m ft. m ft. m ft. m ft. m ft. m ft. m ft. m ft. m FPL FPLR FPLP 22 1,852 564 926 282 617 188 463 141 370 113 309 94 265 81 231 70 206 63 183 56 4101 4301-18 4,688 1,429 2,344 714 1,563 476 1,172 357 938 286 781 238 670 204 586 179 521 159 469 143 4107 4307 4507 16 6,000* 1,829 3,731 1137 2,488 758 1,866 569 1,493 455 1,244 379 1,066 325 933 284 829 253 746 227 4112 4312 4512 14 6,000* 1,829 5,906 1,800 3,937 1,200 2,953 900 2,362 720 1,969 600 1,687 514 1,476 450 1,312 400 1,181 360 4114 4313 4513 Absolute maximum wiring distance for SBUS circuits. 3

Signaling Line Circuits (SLC) SUPPORTED SLC DEVICES 5600 5700 5808 5820XL IFP-25 IFP-50 IFP-100 IFP-1000 IFP-2000 SK SK SK SK IDP IDP IDP IDP IDP HFS Hochiki Hochiki Hochiki HFS Hochiki Hochiki Hochiki Hochiki SK, IDP, HFS Protocols 18-12, 2 Solid Copper Conductors, Unshielded Hochiki Protocol 18-12, 2 Solid Copper Conductors, Unshielded General Riser Plenum ft. m FPL FPLR FPLP 18 3,100 945 4106 4306 4506 16 4,900 1,494 4111 4311 4511 14 7,900 2,408 4113 4313 4513 12 10,000 3,048 4115 4315 4515 General Riser Plenum ft. m FPL FPLR FPLP 18 3,900 1,189 4106 4306 4506 16 6,200 1,890 4111 4311 4511 14 10,000 3,048 4113 4313 4513 backbone Make no bones about it. Honeywell Genesis Series Cable is the foundation for quality installations. Even as fire alarm systems grow more advanced, false alarms and failed emergency notification underscore the importance of system reliability. At Honeywell, we know that failure isn t an option and see fire alarm cable for what it really is the backbone of safety, reliability and your reputation. That s why you need to choose the best cable for the job every time. Honeywell s Genesis Series fire alarm cables are engineered and manufactured with superior workmanship to meet your customer s demands for safe, reliable, and error-free emergency detection and notification. What s more, it s backed by the industry s only 3-for-1 guarantee. When it comes to performance, reliability and service, we ve got your back. Insist on quality and reliability you can trust. Insist on Honeywell Genesis Series Cable. Honeywell Genesis Series Fire Alarm Cables are 100% UL Listed and proudly produced in Pleasant Prairie, WI USA. For more information please call 1-800-222-0060 or visit www.honeywellcable.com 4

Conventional 2&4 Wire Initiating Device Circuits (I) 5820XL IFP-1000 IFP-2000 SK-5208 2-Wire Devices 18-12, Four Solid Copper Conductors, Unshielded 4-Wire Devices 18-12, Two Solid Copper Conductors, Unshielded General Riser Plenum General Riser Plenum ft. m FPL FPLR FPLP 18 3,218 981 4106 4306 4506 16 5,112 1,558 4111 4311 4511 14 8,143 2,482 4113 4313 4513 12 12,953 3,948 4115 4315 4515 ft. m FPL FPLR FPLP 18 3,218 981 4107 4307 4507 16 5,112 1,558 4112 4312 4512 14 8,143 2,482 4114 4313 4513 Maximum distances based on circuit current of 100mA and maximum loop resistance of 50 Ohms. Notification Appliance Circuits (NAC) 5600 5700 5808 5820XL IP-25 IFP-50 IFP-100 IFP-1000 IFP-2000 SK-5208 NUMBER OF NAC CIRCUITS 2 2 4 6 2 2 4 6 8 4 MAXIMUM CURRENT PER NAC CIRCUIT (A) 2.0 2.5 3.0 3.0 2.0 2.5 3.0 3.0 3.0 3.0 MAXIMUM CONTROL PANEL CURRENT (A) 2.0 2.5 6.0 6.0 2.0 2.5 6.0 6.0 9.0 6.0 18-12, Two Solid Copper Conductors, Unshielded Maximum Class-B Wiring Distance 0.5 A 1.0 A 1.5 A 2.0 A 2.5 A General Riser Plenum ft. m ft. m ft. m ft. m ft. m FPL FPLR FPLP 18 438 134 219 67 146 45 109 33 88 27 4106 4306 4506 16 695 212 348 106 232 71 174 53 139 42 4111 4311 4511 14 1,107 337 554 169 369 112 277 84 221 67 4113 4313 4513 12 1,762 537 881 269 587 179 440 134 352 107 4115 4315 4515 Calculations are based on Direct-Current Resistance data for uncoated copper wire, per National Electrical Code (2011 Edition) Table 8, Conductor Properties. 5

Emergency Communication System Panels Panels with Emergency Communication System have a Voice Control Module IFP-100ECS IFP-1000ECS IFP-2000ECS Panel shown is IFP-2000ECS 18-12, Two Solid Copper Conductors, Unshielded at 25 Vrms 5 W 10 W 15 W 20 W 26 W 40 W 50 W General Riser Plenum ft. m ft. m ft. m ft. m ft. m ft. m ft. m FPL FPLR FPLP 18 1,609 490 804 245 536 163 402 123 309 94 201 61 161 49 4106 4306 4506 16 2,556 779 1,278 390 852 260 639 195 492 150 320 97 256 78 4111 4311 4511 14 4,072 1,241 2,036 621 1,357 414 1,018 310 783 239 509 155 407 124 4113 4313 4513 12 6,477 1,974 3,238 987 2,159 658 1,619 494 1,246 380 810 247 648 197 4115 4315 4515 at 70 Vrms 5 W 10 W 15 W 20 W 26 W 40 W 50 W General Riser Plenum ft. m ft. m ft. m ft. m ft. m ft. m ft. m FPL FPLR FPLP 18 12,613 3,844 6,306 1,922 4,204 1,281 3,153 961 2,426 739 1,577 481 1,261 384 4106 4306 4506 16 20,041 6,108 10,020 3,054 6,680 2,036 5,010 1,527 3,854 1,175 2,505 764 2,004 611 4111 4311 4511 14 31,922 9,730 15,961 4,865 10,641 3,243 7,980 2,432 6,139 1,871 3,990 1,216 3,192 973 4113 4313 4513 12 50,777 50,777 15,477 25,389 7,738 16,926 5,159 12,694 9,765 2,976 6,347 1,935 5,078 1,548 4115 4315 4515 Amplifier ECS-125W 18-12, 2 Solid Copper Conductors, Unshielded at 25 Vrms 5 W 10 W 15 W 20 W 26 W 40 W 50 W 75 W 100 W 125 W General Riser Plenum ft. m ft. m ft. m ft. m ft. m ft. m ft. m ft. m ft. m ft. m FPL FPLR FPLP 18 1,609 490 804 245 536 163 402 123 309 94 201 61 161 49 107 33 80 25 64 20 4106 4306 4506 16 2,556 779 1,278 390 852 260 639 195 492 150 320 97 256 78 170 52 128 39 102 31 4111 4311 4511 14 4,072 1,241 2,036 621 1,357 414 1,018 310 783 239 509 155 407 124 271 83 204 62 163 50 4113 4313 4513 12 6,477 1,974 3,238 987 2,159 658 1,619 494 1,246 380 810 247 648 197 432 132 324 99 259 79 4115 4315 4515 6 The above tables assume a uniform distribution of speakers and that a maximum of 20% voltage drop at the last speaker is allowed.

Fire Alarm Cables 18 UNSHIELDED # COND SOL/STR 18 2 SOL 6.5 20 4106 18 4 SOL 6.5 20 4107 18 2 SOL 6.5 19 4306 18 4 SOL 6.5 19 4307 18 2 SOL 6.5 24 4506 18 4 SOL 6.5 24 4507 18 SHIELDED # COND SOL/STR 18 2 SOL 6.5 42 4202 18 4 SOL 6.5 42 4203 18 2 SOL 6.5 42 4402 18 4 SOL 6.5 42 4203 18 2 SOL 6.5 68 4602 18 4 SOL 6.5 68 4603 ARTICLE 760 16 UNSHIELDED # COND SOL/STR MID. CAPACITANCE CABLES UNSHIELDED # COND SOL/STR Mid. Capacitance Fire Alarm Cables 16 2 SOL 4.2 20 4111 16 4 SOL 4.2 20 4112 16 2 SOL 4.1 20 4311 16 4 SOL 4.2 20 4312 16 2 SOL 4.2 27 4511 16 4 SOL 4.1 27 4512 14 UNSHIELDED # COND SOL/STR 12 UNSHIELDED # COND SOL/STR 14 2 SOL 2.6 22 4113 14 4 SOL 2.6 22 4114 14 2 SOL 2.5 22 4313 14 4 SOL 2.5 22 4314 14 2 SOL 2.5 27 4513 14 4 SOL 2.5 27 4514 12 2 SOL 1.6 22 4115 12 2 SOL 2.5 22 4315 12 2 SOL 1.6 30 4515 18 2 SOL 6.3 15 4431 16 2 SOL 4.0 17 4432 16 SHIELDED # COND SOL/STR MID. CAPACITANCE CABLES SHIELDED # COND SOL/STR 16 2 SOL 4.1 46 4206 16 4 SOL 4.1 46 4207 16 2 SOL 4.1 46 4406 16 4 SOL 4.1 46 4407 16 2 SOL 4.1 77 4606 16 4 SOL 4.1 77 4607 14 SHIELDED # COND SOL/STR 12 SHIELDED # COND SOL/STR 14 2 SOL 2.5 52 4208 14 4 SOL 2.5 52 4209 14 2 SOL 2.5 52 4408 14 4 SOL 2.5 52 4409 14 2 SOL 2.5 86 4608 14 4 SOL 2.5 86 4609 12 2 SOL 1.6 56 4210 12 2 SOL 1.7 56 4410 12 2 SOL 1.6 96 4610 18 2 SOL 6.3 34 4441 16 2 SOL 4.0 38 4442 12 2 SOL 1.6 48 4444 For complete cable selection, including Direct Burial and NYC LL5 rated cable, see pages 33-40 in the Honeywell Genesis Series Low Voltage Cable Catalog. All Honeywell fire alarm cables are proudly produced in Pleasant Prairie, WI USA. 7

Honeywell s Genesis Series low voltage wire and cable is produced with innovative equipment and technology. Our leading edge production facility, located in Pleasant Prairie, Wisconsin enables Honeywell to produce the highest quality and cost effective thermostat, electronic, security, fire, sound, voice, data and video wire and cable. See our full line catalog or visit www.honeywellcable.com to see our full product listing of low voltage wire and cable. Thermostat Electronic Shielded and Unshielded Fire Security Sound Video Voice & Data And Much More! For more information: www.honeywellcable.com Automation and Control Solutions Honeywell Cable & Custom Electronics 7701 95th Street Pleasant Prairie, WI 53158-2716 800.222.0060 www.honeywell.com L/SKWEGTCBLB/D September 2013 2013 Honeywell International Inc.