Computer Models For Fire and Smoke

Similar documents
NUMERICAL STUDIES ON BARE CABIN FIRES WITH OPERATION OF SMOKE EXTRACTION SYSTEM

NUMERICAL SIMULATION OF FIRE SPREAD IN TERMINAL 2 OF BELGRADE AIRPORT. PO Box 522, Belgrade, Serbia and Montenegro

5B-3 6th Asia-Oceania Symposium on Fire Science and Technology 17-20, March, 2004, Daegu, Korea

Sprinklers Modeling for Tunnel Road Fire Fighting

Modeling water-mist based suppression of 34 GJ car-deck fires using FDS

OPTIMIZATION OF VENTILATION MODE OF SMOKE CONTROL SYSTEM IN HIGH-RISE BUILDING FIRE

Advantages and Disadvantages of Fire Modelling

Considerations in the Design of Smoke Management Systems for Atriums

A Brief on Performance- Based Design for Building Fire Safety

SIMULATION OF A COMPARTMENT FLASHOVER FIRE USING HAND CALCULATIONS, ZONE MODELS AND A FIELD MODEL

Shalaby Institute of Fire Protection Heyrothsberge, Germany.

CERBERUS: A NEW MODEL TO ESTIMATE SIZE AND SPREAD FOR FIRES IN TUNNELS WITH LONGITUDINAL VENTILATION

Computer Models For Evacuation

CHAM Case Study Numerical Simulation of a Air-to-air Cross-flow Heat Exchanger

Simulation on Counter Flow Heat Exchanger for Indirect Evaporative Cooling Applications Avinash Pandey 1 Dr. P.K.Jhinge 2

Healthy Buildings 2017 Europe July 2-5, 2017, Lublin, Poland

Recent Advances in Fire Suppression Modeling Issues & Perspectives of Fire Safety Engineering Applications

Numerical investigation on the effect of channelled and unchannelled screens on smoke contamination in atriums upper balconies with open upstand

Heat Transfer in Evacuated Tubular Solar Collectors

HOW TO REDUCE ENERGY CONSUMPTION OF BUILT-IN REFRIGERATORS?

Simple Equations for Predicting Smoke Filling Time in Fire Rooms with Irregular Ceilings

Computer Simulation Investigation on the Effect of Channelled and Unchannelled Screens on Smoke Contamination in Atriums Upper Balconies

Study of Hot-air Recirculation around Off-road Tier-4 Diesel Engine Unit Using CFD Abbreviations Keywords Abstract Introduction and Background

Heat transfer and heating rate of food stuffs in commercial shop ovens

Compression of Fins pipe and simple Heat pipe Using CFD

INFLUENCE OF SOLAR RADIATION AND VENTILATION CONDITIONS ON HEAT BALANCE AND THERMAL COMFORT CONDITIONS IN LIVING-ROOMS

A Numerical Study of Smoke Movement along an Inclined Coal Conveyor

A Numerical study of the Fire-extinguishing Performance of Water Mist in an Opening Machinery Space

Shuzo Murakami, Shinsuke Kato, and Taeyeon Kim Institute of Industrial Science, University of Tokyo Tokyo, Japan

Tunnel Fire Dynamics and Evacuation Simulations

Available online at ScienceDirect. Energy Procedia 78 (2015 ) th International Building Physics Conference, IBPC 2015

CHOOSING A FIRE VENTILATION STRATEGY FOR AN UNDERGROUND METRO STATION

Engineering Simulation in Built Environment and Civil Engineering Projects

Yunyong P. Utiskul, Ph.D., P.E., CFEI

Simulation of solar biomass hybrid dryer for drying cashew kernel

NUMERICAL SIMULATION OF THE NEW SOUTH WALES FIRE BRIGADE COMPARTMENT FIRE BEHAVIOUR TRAINING TEST CELL

Experimental Investigation of Tube Configuration for a Surface Condenser

FLACS-Fire. Djurre Siccama Gexcon R&D and Software VP Products. FLUG 3 rd - 4 th. November 2015, Shanghai China

PREDICTING SMOKE DETECTOR ACTIVATION USING THE FIRE DYNAMICS SIMULATOR

Case Study : Evaluation Smoke & Evacuation Performance of a College Auditorium

Computational simulation of road tunnel fire protection by sprinklers

CFD Analysis of temperature dissipation from a hollow metallic pipe through circular fins using Ansys 14.5

SPE SPE The code including the submodels has been extensively tested and validated.

Numerical Stability Analysis of a Natural Circulation Steam Generator with a Non-uniform Heating Profile over the tube length

Travelling Fires for CFD

Recent BRANZFIRE enhancements and validation

Sandeep V. Lutade 1, Krunal Mudafale 2, Ranjan Kishore Mallick 3 1, 2

Space Air Diffusion II

CFD Model of a Specific Fire Scenario

How to Use Fire Risk Assessment Tools to Evaluate Performance Based Designs

AIR CURTAIN GUIDE WHAT IS AN AIR CURTAIN?

CFD Analysis of Fire Characteristics on Subway Junction Station

Fire Research and Education at the University of Maryland

The Research of Performance Comparison of Displacement and Mixing Ventilation System in Catering Kitchen *

Parallelization of an Urban Microscale Flow Model (urbanstream)

VIRTUAL FIRES via COMPUTERS

An experimental study of the impact of tunnel suppression on tunnel ventilation

How design fires can be used in fire hazard analysis

Mathematical Modeling of Fires

ENSC 388: Engineering Thermodynamics and Heat Transfer

DESIGN OF AIR-CONDITIONING SYSTEM FOR SARS WARDS. By Yuguo Li and SARS Busters * Background

CFD Analysis of a 24 Hour Operating Solar Refrigeration Absorption Technology

APPLICATION OF MINI HEAT PIPES FOR THERMAL MANAGEMENT OF OPTO-ELECTRONIC INSTRUMENTS

Test One: The Uncontrolled Compartment Fire

Numerical Simulation of Ventilation Efficiency in Commercial Kitchen

APPLYING LARGE EDDY SIMULATION IN THE STUDY OF FIRE AND SMOKE SPREAD AT UNDERGROUND CAR PARK

ZONE MODEL VERIFICATION BY ELECTRIC HEATER

Design And Analysis Of Centrifugal Pump

Basic Input Data Needed to Develop a High Performance Fan/Blower with Low Noise, Energy Saving and High Efficiency

Risk-informed Airport Fire Engineering Solutions for Operational Continuity

EPSRC Research Project: Real Fires for the Safe Design of Tall Buildings

Aalborg Universitet. Diffuse Ceiling Inlet Systems and the Room Air Distribution Nielsen, Peter Vilhelm; Jensen, Rasmus Lund; Rong, Li

CHAPTER 2 LITERATURE REVIEW

Developing a fire model for offshore QRA

Simulation of Full-scale Smoke Control in Atrium

Characterization of a Heat Sink with Embedded Heat Pipe with Variable Heat Dissipating Source Placement for Power Electronics Applications

Refining and Petrochemical Heater trouble shooting

EXPERIMENTAL AND CFD STUDIES ON SURFACE CONDENSATION

Study of air circulation inside the oven by computational fluid dynamics.

Experimental Study And CFD Based Simulation of Closed Loop Pulsating Heat Pipe Using of Refrigerants (R-134a)

AR/IA 241 LN 231 Lecture 6: Passive Cooling

power-saving period in summer, in which one of the indoor units was forced to change from a cooling mode to a fan mode, was introduced, and the effect

FIRE DYNAMICS IN FAÇADE FIRE TESTS: Measurement, modeling and repeatability

Optimized Finned Heat Sinks for Natural Convection Cooling of Outdoor Electronics

FDS MODELLING OF HOT SMOKE TESTING, CINEMA AND AIRPORT CONCOURSE

FIRESEAT

AIRFLOW PATTERN AND PERFORMANCE ANALYSIS OF DIFFUSE CEILING VENTILATION IN AN OFFICE ROOM USING CFD STUDY

Experimental Investigation of a Brazed Chevron Type Plate Heat Exchanger

Retail solutions by Tenos. Value engineered fire safety solutions for landmark retail developments.

Modeling and Simulation of Axial Fan Using CFD Hemant Kumawat

Impact of heat load distribution and strength on airflow pattern in rooms with exposed chilled beams

6B-2 6th Asia-Oceania Symposium on Fire Science and Technology 17-20, March, 2004, Daegu, Korea

Experiments to Validate the NRCC Smoke Movement Model for Fire Risk-Cost Assessment

Bench Top Cooling Tower H893

ABSTRACT 1. BACKGROUND. THE FIREDASS (FIRE Detection And Suppression Simulation) MODEL

Firefighter Safety in Battery Energy Storage System Fires

September 21, David J. Silvester. Publications Books

Thermal Modeling of Buildings II

CFD STUDY OF FIRE PROTECTION SYSTEMS IN TUNNEL FIRES

PART 1 THERMAL & MECHANICAL ACTIONS. DIF SEK Part 1: Thermal & Mechanical Actions 0/ 50

Transcription:

Computer Models For Fire and Smoke Model Name: JASMINE Version: 3.1 Classification: Very Short Description: CFD or Field A CFD or field model for predicting consequences of fire to evaluate design issues such as the assessment of smoke ventilation design and/or interactions with HVAC and other fire protection measures Modeler(s), Organization(s): Suresh Kumar (Dr), Stewart Miles, Richard Chitty, Building Research Establishment User s Guide: Technical References: Validation References: JASMINE comes with an easier-to-use graphical interface JOSEFINE that has interactive on-line help facility. JOSEFINE provides a fast way of building the geometry of the structure, its thermal properties, specifying the fire source, and heating and ventilation conditions before and during the fire, design of the numerical grid and graphical visualisation of the geometry, grid and the results Cox G and Kumar S. 'Field Modelling of Fire in Forced Ventilated Enclosures', Combustion Science and Technology, 52, 7, (1986). (all of the following papers cite experimental comparisons with the model) Kumar S and Cox G. The Application of a Numerical field Model of Smoke Movement to the Physical Scaling of Compartment Fires, In Proc. Numerical Methods in Thermal Problems ed Lewis R W, Johnson J A and Smith W R, Pinerridge Press, 1983, pp 837-848.

Markatos N C, Malin M R and Cox G. Mathematical Modelling of Buoyancy-Induced Smoke Flow in Enclosures, Int J Heat Mass Transfer, 25, 1982, pp 63-75. Kumar S, Hoffman and Cox G. 'Some validation of JASMINE for fires in hospital wards', Lecture Notes in Engineering No 18, Numerical Simulation of Fluid Flow and Heat Mass Transfer Processes, Springer, 1986, pp 159-169. Kumar S and Cox G. 'Mathematical modelling of fire in road tunnels', In Proc 5th Intl Symposium on Aerodynamics and Ventilation of Vehicle Tunnels, BHRA, 1985, pp 61-76. Pericleous K A, Worthington D R E and Cox G. 'The Field Modelling of Fire in an Air-Supported Structure', In Proc 2nd International Symposium on Fire Safety Science, 1988, p 871. Kumar S. Field Model Simulations of Vehicle Fires in a Channel Tunnel Shuttle Wagon', In Proc 4th International Symposium on Fire Safety Science, Ottawa, Canada, 1994, p 995. Fardell P J, Kumar S, Ellwood J A, Rowley J A and Vollam S. 'A Study of Life Threat in Bus Fires', Interflam '93, p 401, 1993. Miles S D and Cox G. Prediction of fire hazards associated with chemical warehouses, Fire Safety Journal, 27, 265-287, 1996. Miles S D, Kumar S and Cox G. 'Comparisons of 'blind predictions' of a CFD model with experimental data', Proc 6 th International Symposium on Fire Safety Science, Poitiers 1999-to be published. Availability: Price: Available from Building Research Establishment, Watford WD2 7JR, UK Tel: +44 (0) 1923 66 4921 Fax: +44 (0) 1923 66 4910 Email: kumars@bre.co.uk Available on request (both academic and full commercial licenses are available)

Necessary Hardware: Currently supported on PC, and runs under Windows 95 and NT. Requires a minimum of 64MB RAM, 150 MHz processor and 1 Gbyte disc space in excess of system requirements. Can be adapted to workstations (e.g. COMPAC). A 300MHz, 64MB RAM PC can churn out a calculation overnight with a modest number of cells. A 600MHz PC with 1GB RAM is competing with the workstation speeds. Computer Language: FORTRAN 77/90 Size: Contact Information: Approximately 50MB of disk space and a minimum of 64MB RAM required Suresh Kumar (Dr) Building Research Establishment, Garston, Watford WD2 7JR, UK Tel: +44 (0) 1923 66 4921 Fax: +44 (0) 1923 66 4910 Email: kumars@bre.co.uk Alternate: Stephen Welch The University of Edinburgh Faraday Building Rm 2.66 School of Engineering & Electronics The King's Buildings, Mayfield Road Edinburgh EH9 3JL Tel: 0131 650 5734 Fax: 0131 650 6781 Email: S.Welch@ed.ac.uk Detailed Description: The FRS model JASMINE (Analysis of Smoke Movement In Enclosures) uses computational fluid dynamics (CFD) to describe the heat and mass transfer processes associated with the dispersion of combustion products from a fire. The processes of convection, diffusion and entrainment are simulated by the Navier-Strokes equations. JASMINE has been developed, validated and improved over a twenty year period and includes the key processes of buoyancy, convection, entrainment, turbulence, combustion, thermal radiation and boundary heat transfer relevant to the movement of smoke.

JASMINE is a structured, finite-volume code using a staggered, Cartesian grid and is based on the SIMPLEST pressure-correction procedure. The 'upwind' discretisation scheme is employed. Transient solutions are advanced by a first-order, fully implicit scheme. Turbulent closure is provided by a standard, high Reynolds number, twoequation (k, ε) model. Various physical sub-models are included for combustion and radiation processes, gas phase properties (density and specific heat) and solid boundary heat transfer. JASMINE is unique among CFD fire models because of its realistic treatment of the 'fire science' and its extensive validation over a long period. It has been successfully used to simulate fire and smoke movement in a wide variety of construction projects (e.g. atria, hospitals, sport stadia, warehouses, tunnels etc.), as well as in other applications such as a nuclear containment cell, transportation vehicles and marine ships. The end user may specify a multi-compartment enclosure with any number of openings (doors, windows, vents etc.) and one or more fire and/or heat sources. Furthermore, the user may also specify, arbitrary internal and external (Cartesian) blockages, flow rates of ventilation and extraction, external wind boundaries, and locations of active fire protection measures such as heat detectors and sprinklers. JASMINE provides predictions within the volume of the enclosure of gas temperatures, densities, pressures, gas velocities and chemical compositions, in both time and three space dimensions. It also provides estimates of wall surface temperatures, predictions of convective and radiative heat transfer to solid boundaries, and mass and heat flow rates through ventilation openings (natural or forced). In addition to modelling smoke movement inside an enclosure, JASMINE can also be used for modelling smoke propagation in the external environment with different wind and atmospheric conditions. Recently JASMINE has been used for modelling the dispersion of combustion products from a fire inside a warehouse (see enclosed papers on the related work, namely, Modelling the environmental consequences of fires in warehouses and Prediction of fire hazards associated with chemical warehouses ). The current version of JASMINE, with a new graphical user interface JOSEFINE, is a performance-based design and assessment tool for the comprehensive FSE evaluation of new or refurbished constructions. (JOSEFINE can also be used as interface for the CFD model SOFIE, q.v.).the introduction of a graphical user interface is a significant step forward in the twenty-year development and validation of JASMINE. The user interface allows the geometry of any building to be modelled accurately and quickly, with automatic creation of grids within the building. It also provides a fast, easy way of building in the geometry of the structure, its thermal properties and the heating and ventilation conditions before and during the fire. Outputs can be viewed in a highly attractive graphical format. Visualisation facilities allow the user to see how fire and

smoke move through a building and variables such as the velocity, temperature and heat flux levels can be easily obtained for comparative evaluation. The consequences of the fire can then be simulated to address design issues such as when detectors and sprinklers operate, time to untenable conditions from a fire atmosphere and evacuation of occupants. Recent applications of JASMINE include designing smoke ventilation system for a new shopping complex, a cinema complex and a large exhibition hall, and development of a fire safety strategy for the Brussels s airport.