heating, air conditioning, applied systems, refrigeration GENERAL CATALOGUE 2008

Similar documents
Air Conditioning Systems RESIDENTIAL & COMMERCIAL CATALOGUE

EPCEN General CATALOGUE Air Conditioning Systems

RESIDENTIAL & COMMERCIAL CATALOGUE 2008

4-WAY BLOW CEILING MOUNTED CASSETTE Daikin air conditioners for shops, restaurants and offices

Daikin air conditioners for small rooms in multi application

Daikin air conditioners for small rooms in multi application

TODAY, AIR CONDITIONING UNMISTAKABLY FORMS PART OF THE HOSPITALITY PACKAGE THAT YOU WANT TO OFFER YOUR

Daikin air conditioners for shops, restaurants and offices

PRELIMINARY. w w w. d a i k i n e u r o p e. c o m FDQ-B

Do you want a versatile solution to make significant savings? AIR-TO-WATER HEAT PUMP

Daikin air conditioners for shops, restaurants and offices

Daikin Air Conditioning. Daikin air conditioners for shops, restaurants and offices. CEILING SUSPENDED UNIT. UK Price List Attached

Warning. Specifications, designs and other content appearing in this brochure are current as of May 2013 but subject to change without notice.

Daikin air conditioners for shops, restaurants and offices

Wall Mounted Unit ATX-JV / ARX-JV

Daikin air conditioners for shops, restaurants and offices

Product overview 2-3. Technology of Inverter 4-5. Inverter Wall Mounted 6-7. Inverter Ceiling Cassette E Series 8-9

THE INTELLIGENT CHOICE IN COMFORT SINGLE & MULTI TYPE AIR CONDITIONERS

Indoor Dimensions units Ducted Type LG Electronics 6.2 Outdoor units Ducted Type CALOR SRL LG Electronics

SERVICE MANUAL. Commercial Air Conditioning. MULTI upgrade series

FTXS20G FTXS25G FTXS35G FTXS42G FTXS50G FTXS60G FTXS71G

SPLIT-TYPE AIR CONDITIONERS R410A. New PUMY. S series. up to 8* indoor units. ?P100: up to 6 indoor units PUMY-P100YHM PUMY-P125YHM PUMY-P140YHM

HEATINGSERIES POWERFUL SELECTION ZUBADAN SERIES MSZ-FD VABH SERIES

digital remote control WARRANTY 10 years for excanger

Precision Air Conditioners

Air Conditioners Heating & Cooling

Full range. A class energy label. for your home WALL MOUNTED UNIT. air to air heat pumps. FTXS-G

Inverter Wall Mounted

HP 5,65 0,9 6, ,47 B - 8,15 1,9 9, ,5 B - 8,4 1,9 9, ,5 B - 8,5 2,1 9, ,7 A - 8,6 2,1 10, ,71 A -

Air conditioners Heating & Cooling

Europe s new energy label: raising the bar on energy efficiency

REPRINT ZKG PROCESS PROCESS

Air conditioners Heating & Cooling

PRODUCT INFORMATION FWE200DH EXTRACTIVE SCATTERED LIGHT DUST MEASURING DEVICE RELIABLE DUST MEASUREMENT IN WET GASES. Dust measuring devices

for your home FTYN-GX FT(Y)N-F

Atlas and Helios Unit Heaters Janus 05 Air Conditioners AIX Stainless Steel Unit Heaters Atlas STP Door Curtains Jetstream Induction Flow Optimizers

MULTI SYSTEM TECHNOLOGY. 1. Ururu Humidification PART 2 - URURU MULTI

Pure comfort & design

Extension of a Virtual Refrigerant Charge Sensor

for your home FTXS-G WALL MOUNTED UNIT

AIR COOLED PACKAGED AIR CONDITIONERS

Comfort. COMFORT Sabiana circular unit heaters, for ceiling installation only,

Air conditioners Heating & Cooling

PRODUCT INFORMATION VICOTEC320 AIR QUALITY TUNNEL SENSORS TO CONTROL VENTILATION IN ROAD TUNNELS. Tunnel sensors

Daikin MXS SERIES MULTI-ZONE HEATING & COOLING SYSTEMS

Designed. colder climates. for AIR TO AIR HEAT PUMPS FTXS K FTXS-20-25K

Information for end users. Floor standing units. 24/7 comfort in a contemporary package

EEDEN technical data. air conditioning systems FTXS-G2V1B. Indoor units. Split - Sky Air

THE GREAT BRITISH BOILER. Visit Call Get advice, latest prices and help on choosing the right boiler for you.

Pure comfort & design

Air Conditioners Heating & Cooling

w w w. d a i k i n. e u ATXS-E

Daikin Sensira R-32. Refreshingly new. Discreet wall mounted unit providing high efficiency and comfort

PLA-ZRP35/50/60/71/100/125/140BA PLA-RP35/50/60/71/100/125/140BA

Pure air. Because Daikin cares

Daikin air conditioners for shops, restaurant and offices

A tool for professionals.

Air Conditioners. Technical Data FTXS-G

Samsung Air Conditioners

General CATALOGUE Daikin Airconditioning UK Ltd. new

PCSHK1549. Cooling only -50Hz- Heat pump -50Hz-

Heating - Domestic hot water - Cooling. the intelligent way to comfort

QUATERNITY SERIES SINGLE ZONE HEATING & COOLING SYSTEMS

Air Conditioners Heating & Cooling

Heating High/Nom./Low dba 36/33/29 44/39/33 45/41/35 45/41/37 Refrigerant Type R-410A Piping

BENEFIT FROM LOWER FUEL COSTS.

DAIKIN EMURA. FORM. FUNCTION. REDEFINED. THE NEW INDOOR AIR CONDITIONING UNIT FROM DAIKIN.

Daikin air conditioners for your home

Air Conditioners Heating & Cooling

Air Conditioners Heating & Cooling

PCSAU1439A. Inverter series

Air Conditioners Heating & Cooling

Air conditioners Heating & Cooling

PHOTOCATALYTIC AIR CLEANER

Air conditioners, heating & cooling for shops,restaurants and offices

DAIKIN AIR PURIFIER IMPROVED BREATHING COMFORT FOR ALLERGY AND ASTHMA SUFFERERS ABSOLUTE COMFORT

for the retail market, hotels, restaurants and offices

improve your life Today ARGO is a technological and reliable brand, but also a young, dynamic and friendly brand.

DAIKIN 17 SERIES SINGLE ZONE INVERTER WALL-MOUNT SYSTEM S. Up to 17 SEER Up to 9.0 HSPF / Up to 11.5 EER HEAT PUMP AND COOLING ONLY

Daikin air conditioners for your home

NEW FREE MULTI SYSTEM E Up to 5 indoor units with a single outdoor unit FREE MULTI SYSTEM E R410A GAS

Daikin UK Product Catalogue. 1 st April your comfort. our world.

Remote control infrared ARC433B76 ARC433A8 ARC433B69

Information for end users. Floor standing units. 24/7 comfort in a contemporary package

Information for end users. Wall mounted units. Total comfort at home

DSS SERIES SINGLE ZONE INVERTER WALL-MOUNT SYSTEMS. Up to 17 SEER Up to 9.0 HSPF / Up to 11.5 EER HEAT PUMP AND COOLING ONLY

air conditioners for your home, shops, restaurants, offices, small hotels MULTI MODEL APPLICATIONS

Including mounting plate. General Rating Nameplate. Terminal strip with earth terminal

AIR PURIFICATION SOLUTIONS PCAPNZ1017 AIR PURIFIER

SKYAIR SERIES SINGLE ZONE HEATING & COOLING SYSTEMS. Up to 20 SEER / Up to 12.0 HSPF / 14.5 EER INVERTER, VARIABLE-SPEED COMPRESSOR

for your home FLXS-B Flexi type unit air to air heat pumps

AIR CONDITIONERS, HEATING & COOLING for your home

DUAL TECHNOLOGY OCCUPANCY/VACANCY SENSOR SWITCH (WS XX DT XX/WS OS DTDR XX)

Split Type Air Conditioners

Pure comfort & design

SUPERB TECHNOLOGY FOR SUPERB INTERIORS

360 airflow!! PCSSG0814. AIR CONDITIONING SYSTEM [50Hz]

LV Series. SEER 20+ Wall Mount Heat Pump

BENSON AMBIRAD. ... Variante Gas Fired Unit Heaters ... HEATI NG AND VENTILATION S OLUTIONS

Pure comfort & design

Transcription:

heating, air conditioning, applied systes, refrigeration GENERAL CATALOGUE 2008 www.daikin.eu

Foreword THE LEADER IN MANUFACTURING QUALITY AND CUSTOMER SERVICE Since our establishent in Ostend (Belgiu) in 1972, we have updated and expanded our anufacturing facilities, including those opened ore recently in Plzen and Brno (Czech Republic) and Cecchina (Italy) through the acquisition of McQuay - to a point where they are now acknowledged as the ost advanced in their field in Europe. Furtherore, all our plants benefit fro our Japanese parent s policy of zero defect production, super efficient supply chain anageent and unrivalled research and developent support. These substantial production facilities are under pinned by a network of wholly owned affiliate copanies in the UK, France, Gerany, Italy, Spain, Portugal, Poland, Greece, Belgiu, Holland and Central Europe, as well as nuerous independent distributors throughout Europe, Africa and the Middle East supported by several head offices in Ireland, Russia, Turkey, South Africa and the Middle East. Experienced and professional support of this order enables us to aintain an enviably close relationship with international arkets, tailor our product prograe to suit precise regional requireents and respond quickly and efficiently to any area of potential arket expansion. THE LEADER IN PRODUCT QUALITY Daikin produces a highly energy efficient and coprehensive range of quality indoor cliate control products and systes for coercial, residential and industrial applications. Our product portfolio is based on four distinct core pillars : - state of the art direct expansion air conditioning - heat pup residential and light coercial heating, doestic hot water and cooling - applied central cooling and heating - ediu to low teperature refrigeration Each pillar harnesses advanced technologies to deliver axiu energy efficiency and iniu fuel consuption and running costs throughout the equipent life cycle. The width of our product range is also extensive and ebracing in its coverage of these key indoor cliate control disciplines to a point where we are confident of its ability to eet the requireents of our end user, specifier, contractor and installer custoer base at all ties. RESPECT FOR THE ENVIRONMENT Daikin has an enviable record in concern for environental issues and applies it to all areas of the business, ipleenting and in any cases pre-epting, international and local environental protective legislation. We seek to operate a zero waste and zero eissions policy in our anufacturing plants. Our products reflect the concept of cobining axiising energy efficiency with axiu respect for the environent. Their utilisation of heat pup technology for exaple, results in far lower energy consuption and in the case of heating, drastically less CO2 eissions than are achievable with fossil fuel burning systes. Also their incorporation of nuerous detailed features such as inverter control, heat recovery, econoy and quiet operating odes, oveent sensors aong others, enhance user cofort without coproise to either efficiency or the environent. Thus, the products contained in this catalogue are designed to represent the best possible answer to your air conditioning needs. Feel free to contact your local Daikin representative for further inforation and assistance. We are here to serve you! THE FUTURE LEADER Daikin s position at the forefront of air conditioning anufacturing and arketing is well established and widely acknowledged. Nevertheless, over the last few years we widened our product portfolio in order to offer custoers a ore coprehensive choice of indoor cliate control solutions for the hoe, in business and at play. The successful oves into heat pup heating for residential and coercial applications and ediu to low teperature refrigeration for retail and wholesale food outlets are testaent to this policy. But our search for innovative solutions is ongoing and there will certainly be any ore successes to coe. The coon denoinators however, will reain, as they are today, the provision of individual cofort allied to innovation, quality, energy efficiency and environental acceptability. 1

Daikin Europe N.V. Table of Contents Foreword 1 Table of contents 2 Environental awareness 4 Energy labeling 6 Photocatalytic air purifier 8 2

Heating Althera 10 Air Conditioning Residential & Coercial 14 Wall ounted units 17 Flexi type units 36 Floor standing units 39 Concealed ceiling units 42 Cassette units 67 4-Way blow ceiling suspended cassette 87 Ceiling suspended units 91 Rooftops and Packaged Systes 102 Concealed ceiling units 104 Rooftops 108 Twin, Triple, Double Twin & Multi Application 110 Twin, Triple, Double twin applications 112 Multi odel applications 130 VRV 140 VRV 25 years 142 VRV III air-cooled outdoor units 144 VRV III-S 149 VRV -WII water-cooled outdoor units 152 Indoor units 154 Selection prograes 169 Ventilation 170 HRV - Heat reclai ventilation 172 Outdoor air processing unit 174 Air handling applications 175 Control Systes 178 Individual control systes 180 Centralised control systes 181 Network Solutions 182 Applied Systes Chillers 188 Fan coil units 224 Refrigeration Conveni-pack 234 To consult the explanation of the pictograes,please refer to page 240 of this catalogue. 3

Environental Awareness AIR CONDITIONING AND THE ENVIRONMENT Air conditioning systes provide a significant level of indoor cofort, aking possible optiu working and living conditions in the ost extree cliates. In recent years, otivated by a global awareness of the need to reduce the burdens on the environent, soe anufacturers including Daikin have invested enorous efforts in liiting the negative effects associated with the production and the operation of air conditioners. Hence, odels with energy saving features and iproved eco-production techniques have seen the light of day, aking a significant contribution to liiting the ipact on the environent. A nuber of We Care icons are highlighted in green throughout the catalogue to indicate product features that have an ipact on reducing energy consuption: Fan only, Night set ode, Econo ode, Energy efficiency, Moveent sensor and Hoe leave operation 4

DAIKIN S COMMITMENT TO THE ENVIRONMENT The pioneering concern for the environent and natural resources is a part of the entire global Daikin operation at all levels: fro product design, anufacturing processes, down to the responsibility each individual Daikin eployee takes for the environent. This coitent is reflected in three areas: reducing waste in anufacturing and operations, recycling aterials, and designing and producing energy-efficient cliate control equipent. REDUCING WASTE IN MANUFACTURING AND BUSINESS OPERATIONS In 1998, Daikin Europe N.V. becae the first air conditioning anufacturer in Europe to obtain ISO 14001 environental certification. In addition, since 2004, not only the anufacturing plants but Daikin sales copanies as well have obtained ISO 14001 certification, underlining Daikin s coitent to the environent at all levels of our organisation. These certified environental plans include the reduction of waste at all levels. Our environental targets are high: Daikin Europe N.V. is coitted to a zero waste policy whereby as uch as possible of its by products can be reused, recycled or recovered as useful resources. RECYCLING MATERIALS Daikin Europe N.V. is firly coitted to recycling aterials in all areas of its operations. Wastewater is treated before being discharged into the city drainage syste, with the recovered sludge being a useful ingredient in ceent anufacturing. Other waste is also carefully sorted and recycled, supported by a continually evolving factory layout that encourages the optiu use of resources. In addition to recycling, we invest significantly in returnable packaging. The sae high deands are also iposed on our suppliers. Eliinating waste and optiu recycling reduce raw aterial consuption and contribute to efficient anufacturing and operating processes, eaning fewer burdens on the environent. ENERGY EFFICIENT CLIMATE CONTROL EQUIPMENT Daikin s coitent to being a leader in environental developents has led to a string of innovations in cliate control equipent: Daikin s use of inverter technology for exaple reduces start-up tie by 33% and allows the copressor to consue only the power it actually needs to eet the cooling/heating needs of the oent. Linking the use of inverter technology to reluctance DC copressor otors has further iproves efficiency, allowing Daikin units to obtain the highest efficiency ratings in the arket. Daikin also produces coputerised air conditioning onitoring and control systes designed to ensure axiu energy efficiency at all ties, such as Daikin s latest I-controller technology which offers custoers refined and energy efficient control of Daikin heat recovery air conditioning installations, including reote onitoring via the Internet. This list of innovations could be expanded endlessly. More iportantly, it clearly deonstrates that technological innovation and concern for the environent can go hand in hand. At Daikin, these environental priorities for an integral part of our corporate culture and are reflected in all of our products. Choosing Daikin eans you can be sure that the cooling systes you use are the safest possible for the environent. 5

ing Energy labeling is part of a wider European Cliate Change progra that targets energy efficiency as one ethod of reducing CO2 eissions in order to eet the targets of the Kyoto protocol. By this eans the European Coission hopes that iproved awareness will result in custoers purchasing the ost econoical (ecological) answer to their needs. Energy Manufacturer Outside unit Inside unit More effi cient Less efficient A B C D E F G Annual energy consuption, in cooling ode (Actual consuption will depend on how the apliance is used and cliate) Cooling output Energy effi ciency ratio Full load (the higher the better) Cooling only Cooling + Heating Air cooled Water cooled Heat output Heating perforance A: higher G: lower Noise (db(a) re 1 pw) kw kw WHAT? The energy label provides inforation on the energy consuption of the unit. Air conditioning units (with cooling capacity 12kW) are classified in seven different categories (A to G), according to their energy consuption and color coded according to the category to which they belong. The ost energy efficient units will be included in the A category, indicated by a green arrow on the label less efficient units will belong in G class, indicated by a red arrow on the label. The end user can easily copare the efficiency of equal types of units fro different brands. THE LABEL? WHAT IS MENTIONED ON THE LABEL? Logo and nae of anufacturer; nae of indoor and outdoor unit (*) Energy efficiency class of the unit in cooling ode: A EER 3.20 B 3.20 EER 3.00 C 3.00 EER 2.80 D 2.80 EER 2.60 E 2.60 EER 2.40 F 2.40 EER 2.20 G 2.20 EER Further inforation is contained in product brochures Air-conditioner Directive 2002/31/EC 6

INDICATED ANNUAL ENERGY CONSUMPTION This figure indicates the approxiate aount of energy consued per year by the unit, based on a standard household odel. The annual consuption is calculated by ultiplying the total power input by an average of 500 hr per year IN COOLING MODE AT FULL LOAD. In order to calculate the cost of annual energy consuption, you erely ultiply this figure by your electricity tariff. COOLING OUTPUT Cooling output is defined as the cooling capacity in kw of the appliance, operating in cooling ode at full load. It is iportant to choose an air conditioning unit with a rated output sufficient for your cooling/heating requireents. An oversized unit can result in frequent on/off cycling, which shortens its service life - an undersized unit will not provide adequate cooling/heating. To deterine the appropriate output, contact the anufacturer or your local dealer/installer. ENERGY EFFICIENCY RATIO (EER) This is the cooling output of the unit divided by the aount of electricity the unit requires to deliver it (total power input). In other words, the higher the EER, the greater the energy efficiency. TYPE TYPE OF UNIT: it indicates if the unit is a cooling only or cooling/heating syste COOLING MODE: it indicates if the unit is air cooled or water cooled HEATING OUTPUT Heating output is defined as the heating capacity in kw of the appliance, operating in heating ode at full load. ENERGY EFFICIENCY CLASS OF THE UNIT IN HEATING MODE: A EER 3.60 B 3.60 EER 3.40 C 3.40 EER 3.20 D 3.20 EER 2.80 E 2.80 EER 2.60 F 2.60 EER 2.40 G 2.40 EER Noise level: only for portable units. (*): For ulti-odels Daikin chooses only to ention 1 outdoor unit with a axiu of 2 indoor units (wall ounted type) - for other units we refer to the ulti brochure. 7

MC707VM-W MC707VM-S Photocatalytic Air Purifier PURE AIR FOR FREE AND HEALTHY BREATHING stylish design iproved perforance unprecedented cofort super quiet operation easy to aintain portable no installation THREE TIMES PURIFICATION, A GOOD DEED FOR YOUR HEALTH Pollen, dust and pet hair are just soe of the potential causes of allergies, astha and respiratory probles. A Daikin air purifier cleans the air and relieves you of these troubles thanks to a three-part operation: allergen reoval virus and bacteria reoval odour reoval Daikin has already received great praise for its air purifiers: a UK allergy certificate and the daikin TüV award confir the efficiency of our units. Pre-filter (with catechin) Reoves large dust particles and pet hairs. Bio-antibody filter Airborne viruses are captured and reoved. Plasa ionizer Dust and pollen are positively charged and sent to the electrostatic filter. Dirty air 8

MC707VM-W MC707VM-S MC707VM-W/S Model MC707VM-W/S Power supply 1~, 220-240/220-230V, 50/60Hz Diensions HxWxD 533x425x213 Colour (W) = White + sparkling silver or (S) = Sparkling silver + etallic ocean blue Kg 8.7 Mode (50Hz) Turbo H M L Silent Power input kw 0.055 0.023 0.014 0.010 0.008 Sound pressure level db(a) 47 38 31 24 16 Sound power level db(a) 62 52 40 39 31 Air fl ow rate 3 /h 420 285 180 120 60 Dust collecting ethod Plasa ionizer (electrostatic dust collection) + Electrostatic dust collection fi lter Deodorising Method Flash Streaer + Titaniu apatite photocatalytic fi lter + Deodorising catalyst Deodorising perforance (%) 95 Regenerate ethod The Flash Streaer activates the photocatalytic reaction Bacteria fi ltering ethod Bio-Antibody fi lter + Flash Streaer + Titaniu apatite photocatalytic fi lter Filter Dust For Pleated fi lter collection and Function Deodorisation + disinfection + dust collection + adjuvant reoval deodorisation Lifetie 1 fi lter/1 year Bio-Antibody fi lter New Pre-fi lter Catechin pre-fi lter Flash Streaer unit Flash Streaer High-speed electrons are generated by the Flash Streaer. These electrons powerfully break down odours and foraldehyde. Electrostatic dust collection filter Positively charged dust and pollen are adsorbed by the negatively charged filter. Front Deodorising catalyst Odours are adsorbed and broken down before the air is returned into the roo. Purified air Back Titaniu Apatite Photocatalytic Filter Odour, bacteria and viruses are adsorbed and decoposed. 9

The intelligent way to cofort CHOOSING ALTHERMA... NOTHING BUT BENEFITS! LESS ENERGY, PLEASANT WARMTH IN THE HOME Althera heats up to 3 ties ore efficiently than a traditional heating syste based on fossil fuels or electricity. By aking use of the heat in the outside air, you use uch less energy, while still enjoying a stable, pleasant heat in your surroundings. On top, aintenance requireents are inial, aking your running cost low. Thanks to the inverter technology, your energy savings are even greater. MINIMAL INSTALLATION COST Althera takes heat fro the air. No digging or excavation works are required. Both the outdoor and indoor units are copact. The external unit can be located easily outside any building, including apartents. Without flaes or fues, there is no need for a chiney or constant ventilation in the roo, where Althera s indoor unit is installed. FLEXIBLE CONFIGURATIONS Althera can be configured for use in both new and refurbishent applications and connects to standard low teperature radiators, under floor heating or fan coil units. If you already have a heating syste, you don t need to change everything. COMPLETE COMFORT FOR YOUR FAMILY Althera satisfies your heating requireents but it can also supply your sanitary hot water and it coes with a cooling option for hot suer days. ABSOLUTELY SAFE Althera doesn t need oil, gas or other hazardous substances naturally reducing a potential risk that goes together. Moreover, you don t need a gas connection or a fuel tank. No risk of intoxication, sell or pollution fro leaking tanks. 10

INDOOR UNIT EKHBH008AA*** EKHBX008AA*** EKHBH016AB*** EKHBX016AB*** Function Heating only Reversible Heating only Reversible Diensions HxWxD 922x502x361 922x502x361 922x502x361 922x502x361 Leaving water teperature range Drain valve Material Colour heating C 15~50 15~55 cooling C - 5~22-5 - 22 Yes Epoxy polyester painted galvanized steel RAL 9010 (neutral white) FACTORY MOUNTED HEATER Power supply Capacity steps EKHBH(X)008AA3V3 / EKHBH(X)016AB3V3 1 ~/230V 1 EKHBH(X)008AA6V3 / EKHBH(X)016AB6V3 1 ~/230V 2 EKHBH(X)008AA6WN / EKHBH(X)016AB6WN 3 ~/400V 2 EKHBH(X)008AA6T1 / EKHBH(X)016AB6T1 3 ~/230V 2 EKHBH(X)008AA9WN / EKHBH(X)016AB9WN 3 ~/400V 2 EKHBH(X)008AA9T1 / EKHBH(X)016AB9T1 3 ~/230V 2 OUTDOOR UNIT ERHQ006AD ERHQ007AD ERHQ008AD ERHQ011AA ERHQ014AA ERHQ016AA Diensions HxWxD 735x825x300 1,349x980x420 Noinal capacity 7 heating kw 5.75 6.64 8.43 11.2 14.0 16.0 cooling kw 7.20 8.16 8.37 13.9 17.3 17.8 Noinal input heating kw 1.26 1.58 2.08 2.46 3.17 3.83 cooling kw 2.27 2.78 2.97 3.79 5.78 6.77 COP 3.18 3.13 3.00 4.55 4.42 4.18 EER 2.37 2.26 2.21 3.67 2.99 2.63 Operation range heating C -20 ~ 25-20 ~ 35 cooling C 10 ~43 10 ~43 doestic ode C -20 ~ 43-20 ~ 43 Sound pressure level heating dba 61 61 62 64 64 66 cooling dba 63 63 63 64 66 69 56 103 charge 1.7 3.7 Power supply 1 ~ /230V/50Hz 1 ~ /230V/50Hz Recoended fuses A 20 32 Measuring conditions EKHBH(X)008AA: Heating Ta DB/WB 7 C/6 C - LWC 35 C (DT=5 C) - Cooling Ta 35 C - LWE18 C (DT=5 C) Measuring conditions EKHBH(X)016AB: Heating Ta DB/WB 7 C/6 C - LWC 35 C (DT=5 C) - Cooling Ta 35 C - LWE18 C (DT=5 C) SOLAR KIT EKSOLHWAV1 Diensions HxWxD 770x305x207 Heat exchanger pressure drop kpa 21.5 Max. inlet tep C 110 heat ex. capacity W/K 1,400 Abient teperature Power supply Power supply intake ax. C 35 in. C 1 indoor unit DOMESTIC HOT WATER TANK EKHWS150A3V3 EKHWS200A3V3 EKHWS300A3V3 EKHWS2003Z2 EKHWS200A3Z2 Water volue l 150 200 300 200 300 Max. water teperature C 85 Height 900 1,150 1,600 1,150 1,600 Diaeter 580 Booster heater kw 3 Power supply 1 ~ /230V/50Hz 2 ~ /400V/50Hz Material inside tank Stainless steel (DIN 1.4521) Material outside casing Epoxy-coated ild steel Colour Neutral white Epty weight 37 45 59 45 59 11

The solution for your total cofort Althera is a split syste consisting of an outdoor unit and an indoor hydro-box that can be connected to all standard low teperature radiators and underfloor heating systes. OUTDOOR UNIT An efficient use of energy fro the air Althera uses a natural, renewable source of energy. The outdoor unit derives heat fro the surrounding air and raises its teperature until it is high enough to heat a hoe. This heat is then transitted to the indoor unit through refrigerant pipes. An advantage of this is that the pipes can never freeze. The copact outdoor unit is easily installed and can also be used in residences without a garden. Indoor unit Doestic hot water tank Did you know that...? The althera syste can be perfectly cobined with solar collectors to produce hot water. The sun provides 30 to 70% of the energy required for our hot water needs. Althera, your total solution, thinks of the future. Outdoor unit INDOOR UNIT The heart of the althera syste The indoor unit heats the water that circulates through your low teperature radiators, floor heating systes or fan coil units and provides you with doestic hot water. If you opt for the cobination of heating and cooling, then the indoor unit can also decrease the water teperature to distribute a refreshing coolness. 12

DOMESTIC HOT WATER TANK Fan coil unit Low teperature radiator For low energy cosuption As for your doestic hot water, Althera is just as clever. The unique lay-out and special placeent of different eleents axiise energy efficiency. The water inside the storage tank is priarily wared up by theral energy fro the outside air, thanks to a heat exchanger connected to the heat pup. However, an additional electrical heating eleent in the doestic water tank can take care of extra heat you need in your shower, bath or sink. At necessary intervals the water is autoatically heated to 70 C in order to stay clear of bacteria. With Althera you can enjoy delightfully war and perfectly safe water at all ties. Depending on the daily consuption of hot water, Althera doestic hot water tanks coe in three different sizes, with the largest one being the ost efficient. Doestic hot water INTELLIGENT TEMPERATURE REGULATOR Under floor heating The operation of the syste is integrated in the indoor unit. With Althera, it is possible to regulate your heating and () cooling syste according to your needs. Your installer can set up a full weekly prograe for you, per hour or per day. In this way, the teperature is reduced autoatically at night or during your holiday, and it is once again pleasantly war when you get up or return hoe. The floating setpoint, is a built-in variable therostat that adjusts the water teperature to the outdoor teperature. By keeping the water teperature at the lowest possible level, axiu efficiency of the syste is achieved. The syste can be cobined with additional teperature regulating systes with separate therostats for living roos, bedroos, and so forth. 13

14

Daikin residential air conditioning is the odern, econoic and efficient way to switch on to springtie - in the living roo, dining roo, kitchen or bedroo, night and day, throughout the year. Daikin air conditioning units are easy to install, easy to use, ultra reliable, quiet running and coe in an elegant and up to date range of wall, floor and ceiling ounted indoor odels. Also, the incorporation of inverter control enables Daikin to bring air conditioning technology of the future to the residential arket today. Inverter control cuts start up tie and energy consuption by alost a third, alters unit output to suit outdoor conditions, iproves perforance relative to power input, ensures a ore even roo teperature and eliinates power surges and stop/start cycles. Residential & Coercial 1. Wall ounted units FTXR-E / RXR-E 17 FTXG-E / RXG-E 19 FTXS-G / RXS-G 21 FTX-GV / RX-GV 22 FTXS-F / RXS-F 23 FTYN-GX / RYN-GX 24 FTYN-F / RYN-E 25 FAQ-B / RQ-B 26 FAQ-B / RZQS-C 27 FAQ-B / RZQ-C 28 FAQ-B / RZQ-B 29 FTXS-G / RKS-G 30 FTK-GV / RK-GV 31 FTKS-F / RKS-F 32 FTN-F / RN-E 33 FAQ-B / RR-B 34 2. Flexi type units new new new new new FLXS-B / RXS-G 36 FLKS-B / RKS-G 37 FLKS-B / RN-E 38 3. Floor standing units FVXS-F / RXS-G 39 FVXS-F / RKS-G 40 FVQ-B / RZQS-C 41 4. Concealed ceiling units new FDXS-E / RXS-G 42 FDXS-C / RXS-G 43 FDXS-C / RXS-F 44 FBQ-B / RXS-G 46 FBQ-B / RXS-F 47 FBQ-B / RQ-B 48 FBQ-B / REQ-B 49 FBQ-B / RZQS-C 50 FBQ-B / RZQ-C 51 FBQ-B / RZQ-B 52 FDQ-B / RQ-B 53 FDQ-B / RZQS-C 54 FDQ-B / RZQ-C 55 FDQ-B / RZQ-B 56 FDEQ-B / REQ-B 58 FDKS-E / RKS-G 59 FDKS-C / RKS-G 60 FDKS-C / RKS-F 61 FBQ-B / RKS-G 62 FBQ-B / RKS-F 63 FBQ-B / RN-E 64 FBQ-B / RR-B 65 FDQ-B / RR-B 66 5. Cassette units FCQ-C / RXS-G 67 FCQ-C / RXS-F 68 FCQ-C / RQ-B 69 FCQ-C / REQ-B 70 FCQ-C / RZQS-C 71 FCQ-C / RZQ-C 72 FCQ-C / RZQ-B 73 FCQH-C / RZQS-C 75 FCQH-C / RZQ-C 76 FCQH-C / RZQ-B 77 FFQ-B / RXS-G 78 FFQ-B / RXS-F 79 FCQ-C / RKS-G 80 FCQ-C / RKS-F 81 FCQ-C / RN-E 82 FCQ-C / RR-B 83 FFQ-B / RKS-G 84 FFQ-B / RKS-F 85 FFQ-B / RN-E 86 6. 4-Way blow ceiling suspended cassettes FUQ-B / RQ-B 87 FUQ-B / RZQ-C 88 FUQ-B / RZQ-B 89 FUQ-B / RR-B 90 7. Ceiling suspended units FHQ-B / RXS-G 91 FHQ-B / RXS-F 92 FHQ-B / RQ-B 93 FHQ-B / REQ-B 94 FHQ-B / RZQS-C 95 FHQ-B / RZQ-C 96 FHQ-B / RZQ-B 97 FHQ-B / RKS-G 98 FHQ-B / RKS-F 99 FHQ-B / RN-E 100 FHQ-B / RR-B 101 15

Good Design Award URURU SARARA A unique cobination of huidification, dehuidification, ventilation and air purification Good teperature control is not all that is needed for a cofortable indoor cliate. Precision control of huidity and ventilation of the roo is essential. Thanks to the URURU SARARA, you can huidify, dehuidify, ventilate and purify. The unit is fitted with filters that also filter dust, pollen and soke. You can also adjust the air purification to eet your specific needs. Thanks to the ventilation syste, containated indoor air in a space is replaced with fresh outdoor air. URURU huidification: Pleasant, even during heating The URURU huidification syste absorbs oisture fro the outdoor air and transports it to the indoor unit, quickly and efficiently huidifying the roo. Thanks to the perfect cobination of huidification and air conditioning, your roo heats evenly. SARARA dehuidification: Feel the difference! When huidity is too high, the SARARA dehuidication syste ensures that it is lowered without changing the roo teperature. That is ideal for you, because lower huidity eans you feel ore cofortable. The ideal huidity Cofortable air flow Powerful air purification Stylish design (good design award) Energy saving and high efficiency: one unit of energy is converted into ore than five units of energy for cooling or heating 16

FTXR-E / RXR-E Wall Mounted Unit URURU huidifi cation: aintains a cofortable huidity level without any separate water supply SARARA dehuidifi cation: aintains a cofortable and fresh indoor environent by reoving oisture fro the air without lowering the teperature Energy effi cient: full range A class labels (EER = 5.00/COP = 5.14) Powerful ventilation: refreshes the roo within 2 hours Powerful air purifi cation: increases indoor air quality with Daikin Flash Streaer technology Cofortable air fl ow Stylish design Other features: oisturizing operation ode, breeze cooling air fl ow, cofort sleep operation, ould shock operation ARC447A FTXR28,42,50E 5 steps Titaniu apatite photocatalytic air purifi cation fi lter RXR28,42,50E HEAT PUMP INVERTER Indoor Units FTXR28EV1B9 FTXR42EV1B9 FTXR50EV1B9 Capacity Cooling capacity Miniu kw 1.55 Standard kw 2.8 4.2 5.0 Maxiu kw 3.6 4.60 5.50 Heating capacity Miniu kw 1.30 Standard kw 3.6 5.1 6.0 Maxiu kw 5.00 5.6 6.20 EER / COP Cooling / Heating 5.00 / 5.14 4.00 / 4.32 3.42 / 3.97 Annual energy consuption 280 525 730 cooling / heating A / A Air Flow Rate Cooling High/Mediu/Low/Silent Operation ³/in Heating High/Mediu/Low/Silent Operation ³/in Sound Power Cooling Mediu dba Heating Mediu dba Sound Pressure Cooling High/Mediu/Low/Silent Operation dba Heating High/Mediu/Low/Silent Operation dba 209x890x305 14 11.1 / 8.8 / 6.5 / 5.7 12.4 / 9.6 / 6.8 / 6.0 13.3 / 10.3 / 7.3 / 6.5 12.4 / 9.8 / 7.3 / 6.5 12.9 / 10.2 / 7.7 / 6.8 14.0 / 11.1 / 8.3 / 7.3 55 58 60 57 58 60 39 / 33 / 26 / 23 42 / 35 / 27 / 24 44 / 37 / 29 / 26 41 / 35 / 28 / 25 42 / 36 / 29 / 26 44 / 38 / 31 / 28 Outdoor Unit RXR28EV1B9 RXR42EV1B9 RXR50EV1B9 Heating Min~Max CWB Sound Pressure (Standard) Cooling dba Heating dba Piping connections Liquid (OD)/Gas/Drain Piping Length (Maxiu) 693x795x285 48-10~43-20~18 60 62 46 48 46 48 50 6.35 / 9.52 / 18 10 17

Designed for people who do not only care for quality but also care for stylish design STYLISH AND COMPACT DESIGN Daikin succeeded in creating an indoor unit with such a sleek profile, that you won t believe it is an air conditioning unit. In standby ode, the discharge opening is closed, resulting in a copact depth of only 15c. When starting the unit up, the entire front panel slides soothly open. Good Design Award For this odel, Daikin even received the Good Design Award in Japan. SENSATIONAL THINNING TECHNOLOGY CLEAN AND COMFORTABLE AIR FLOW For the fist tie in history, a titaniu apatite photocatalytic air purification filter is integrated in an air conitioning unit. This to increase the active surface area for effective purification and deodorisation, even when a high volue of air is required. Super quiet: The indoor/outdoor unit silent operation function brings us cofort by offering an industry top-level quiet operation of 22dB(A) for the indoor unit and 43dB(A) for the outdoor unit. 25% size reduction Cooling ode Heating ode COMFORT MODE FTK(X)S High efficiency slit fin heat exchanger Miniature cross flow fan FTXG The new wide-angle distribution flap reassures draught free operation. During cooling operation the flap angle turns horizontally to prevent cold air blowing directly on the body, while during heating operation it turns downward vertically to send the war air directly to the feet. The blade configuration has been optiized to achieve quiet operation and powerful air flow, while reducing the fan s diaeter by 20% copared to conventional odels. SUPERB ENERGY EFFICIENCY Daikin has further iproved the energy efficiency. At the sae tie it realized substantial energy savings copared to conventional odels by achieving an industrial top class EER of 4.03 and COP of 4.15. These top of the class values are achieved by the following 3 technologies: PAM Inverter control Reluctance DC otor + DC Fan otor Swing copressor 3-D AIR FLOW This function cobines Vertical and Horizontal auto-swing to circulate a strea of cool/war air right to the corners of even large spaces. 18

FTXG-E / RXG-E Wall Mounted Unit State of the art design: sleek, copact and stylish outlook Available in 2 colour variations: at crystal white and at crystal silver Lightweight and copact Easy to clean fl at suction grille Superb energy effi ciency Moveent sensor saves power consuption in unoccupied roos Cofort ode reassures draught free operation thanks to the new wide angle distribution fl ap The new titaniu apatite photocatalytic air purifi cation fi lter increases the active surface area for effective purifi cation and deodorisation Horizontal and vertical auto-swing 3D-air fl ow ensure effi cient air and teperature distribution. Powerful ode can be selected for rapid cooling or heating Indoor / outdoor unit silent operation ARC433A41 FTXG25,35E_S FTXG25,35E_W RXG25,35E (5 steps) (standard) (integrated titaniu apatite) MXS () HEAT PUMP INVERTER Indoor Units FTXG25EV1BW FTXG25EV1BS FTXG35EV1BW FTXG35EV1BS Capacity Cooling capacity Miniu kw 1.3 1.4 Standard kw 2.5 3.5 Maxiu kw 3.0 3.8 Heating capacity Miniu kw 1.3 1.4 Standard kw 3.4 4.2 Maxiu kw 4.5 5.0 EER / COP Cooling / Heating 4.03 / 4.15 3.30 / 3.72 Annual energy consuption 310 530 cooling / heating A / A Air Flow Rate Cooling High/Mediu/Low/Silent Operation ³/in Heating High/Mediu/Low/Silent Operation ³/in Sound Power Cooling High dba Heating High dba Sound Pressure Cooling High/Mediu/Low/Silent Operation dba Heating High/Mediu/Low/Silent Operation dba 275x840x150 9.0 7.7 / 6.1 / 4.7 / 3.8 8.1 / 6.5 / 4.9 / 4.1 9.0 / 7.9 / 6.7 / 5.4 9.6 / 8.2 / 6.7 / 5.9 56.0 57.0 56.0 57.0 38.0 / 32.0 / 25.0 / 22.0 39.0 / 33.0 / 26.0 / 23.0 38.0 / 33.0 / 28.0 / 25.0 39.0 / 34.0 / 29.0 / 29.0 Outdoor Unit RXG25E2V1B RXG35E2V1B Heating Min~Max CWB Sound Pressure (Standard) Cooling dba Heating dba Piping connections Liquid (OD)/Gas/Drain Piping Length (Maxiu) Max. internunit level difference 550x765x285 32 10.0~46.0-15.0~20.0-15~20 61.0 62.0 46.0 47.0 47.0 48.0 1~/230V/50Hz 6.35 / 9.52 / 18 20 15.0 19

High tech on the inside, Attractive design on the outside SPECIAL FEATURES 2 area intelligent eye With this function, the air flow is sent to a zone other than where the person is located at that oent. If two people are detected in the roo, the oveent sensor, together with the cofort ode (cooling directed at the ceiling, heating directed at the floor), will see to it that the air flow is projected away fro the occupants. If no people are detected, the unit will autoatically switch over to the energy-efficient setting. Reote control The new infrared reote control has a very stylish design, is user-friendly and equipped with a weekly tier. With this tier, you can prograe a 7-day schedule with 4 different actions per day. Furtherore, the convenient copy function allows you to very quickly copy any day s prograe to one or ore other days. Should there be a alfunction in the air conditioner, you can read the code on the LCD screen of the reote control and easily find the appropriate solution. ARC452A3 Energy saving during operation standby Once the standby current-saving function has been activated, the current consuption when operating on standby will be reduced by about 80%. If no people are detected for an extended period of tie, i.e. ore than 20 inutes, the syste will autoatically switch to the current-saving ode. 20

FTXS-G / RXS-G Wall Mounted Unit 2 area intelligent eye: air fl ow is sent to the area in a roo where no person is detected Energy saving during stand by ode: reduction of energy fro 10W to 2W Weekly tier: allows to progra the unit on a weekly basis Flat front panel: its stylish appearance blends easily within any interior décor and is ore easy to clean. Cofort ode reassures draught free operation 3D air fl ow Dual air discharge fl ow for better air distribution Consues up to 30% less energy than noninverter units ECONO ode decreases power consuption so that other appliances that need large power supply can be used Indoor / outdoor unit silent operation Powerful ode can be selected for rapid cooling or heating Reaches set teperature ore quickly Titaniu apatite photocatalytic air purifi cation fi lter absorbs icroscopic particles, decoposes odours and even deactivates bacteria and viruses ARC452A3 FTXS20,25,35,42,50G RXS20,25,35,42G 5 steps standard (integrated titaniu apatite) HEAT PUMP INVERTER Indoor Units FTXS20G2V1B FTXS25G2V1B FTXS35G2V1B FTXS42G2V1B FTXS50G2V1B Capacity Cooling capacity Miniu kw 1.3 1.3 1.4 1.7 1.7 Standard kw 2.0 2.5 3.5 4.2 5.0 Maxiu kw 2.8 3.2 4.0 5.0 5.3 Heating capacity Miniu kw 1.3 1.3 1.4 1.7 1.7 Standard kw 2.7 3.4 4.0 5.4 5.8 Maxiu kw 4.3 4.7 5.2 6.0 6.5 EER / COP Cooling / Heating 4.26 / 4.29 4.55 / 4.53 4.02 / 4.17 3.44 / 3.67 3.29 / 3.69 Annual energy consuption 235 275 435 610 760 cooling / heating A / A A / A A / A A / A A / A Air Flow Rate Cooling High ³/in Heating High ³/in Sound Power Cooling High dba Heating High dba Sound Pressure Cooling High/Mediu/Low/Silent Operation dba Heating High/Mediu/Low/Silent Operation dba 295x800x215 295x800x215 295x800x215 295x800x215 295x800x215 9 9 10 10 10 9.0 9.0 10.1 9.8 10.2 9.3 9.6 10.5 10.1 10.9 54 54 57 58 59 54 55 57 58 60 38 / 32 / 25 / 22 38 / 32 / 25 / 22 42 / 34 / 26 / 23 42 / 38 / 33 / 30 43 / 39 / 34 / 31 38 / 33 / 28 / 25 39 / 34 / 28 / 25 42 / 36 / 29 / 26 42 / 38 / 33 / 30 44 / 39 / 34 / 31 Outdoor Unit RXS20G2V1B RXS25G2V1B RXS35G2V1B RXS42G2V1B RXS50G2V1B Heating Min~Max CWB Sound Pressure (Low) Cooling dba Heating dba Sound Pressure (High) Cooling dba Heating dba Piping connections Liquid (OD)/Gas/Drain Piping Length (Maxiu) 550x765x285 550x765x285 550x765x285 550x765x285 735x825x300 34 34 34 39 48-10~46-10~46-10~46-10~46-10~46-15~20-15~20-15~20-15~20-15~18 61 61 63 63 62 43 43 44 44 44 44 44 45 45 45 46 46 48 48 48 47 47 48 48 48 6.35 / 9.52/18 6.35 / 9.52/18 6.35 / 9.52/18 6.35 / 9.52/18 6.35 / 12.7/18 20 20 20 20 30 21

FTX-GV / RX-GV Wall Mounted Unit Flat front panel: its stylish appearance blends easily within any interior décor and is ore easy to clean. Lightweight and copact Consues up to 30% less energy than noninverter units Dual air discharge fl ow for better air distribution ECONO ode decreases power consuption so that other appliances that need large power supply can be used Indoor unit On/Off switch Indoor unit silent operation Titaniu apatite photocatalytic air purifi cation fi lter Anticorrosion treatent of outdoor heat exchanger fi n Powerful ode can be selected for rapid cooling or heating Energy saving during stand by ode: reduction of energy fro 10W to 2W ARC433A87 FTX20,25,35GV RX20,25,35GV 5 steps standard HEAT PUMP INVERTER Indoor Units FTX20GV1B FTX25GV1B FTX35GV1B Capacity Cooling capacity Miniu kw 1.3 Standard kw 2.0 2.5 3.2 Maxiu kw 2.6 3.0 3.8 Heating capacity Miniu kw 1.3 Standard kw 2.5 2.8 3.4 Maxiu kw 3.5 4.0 4.8 EER / COP Cooling / Heating 3.62 / 3.90 3.38 / 3.68 3.37 / 3.74 Annual energy consuption 275 370 470 cooling / heating A / A Air Flow Rate Cooling High/Mediu/Low/Silent Operation ³/in Heating High/Mediu/Low/Silent Operation ³/in Sound Power Cooling High dba Heating High dba Sound Pressure Cooling High/Mediu/Low/Silent Operation dba Heating High/Mediu/Low/Silent Operation dba 283x770x198 7 9.1 / 7.4 / 5.9 / 4.7 9.2 / 7.6 / 6.0 / 4.8 9.3 / 7.7 / 6.1 / 4.9 9.4 / 7.8 / 6.3 / 5.5 9.7 / 8.0 / 6.3 / 5.5 10.1 / 8.4 / 6.7 / 5.7 55 56 57 55 56 57 39 / 33 / 25 / 22 40 / 33 / 26 / 22 41 / 34 / 27 / 23 39 / 34 / 28 / 25 40 / 34 / 28 / 25 41 / 35 / 29 / 26 1~/220-230-240V/50Hz Outdoor Unit RX20GV1B RX25GV1B RX35GV1B Heating Min~Max CWB Sound Pressure (High) Cooling dba Heating dba Piping connections Liquid (OD)/Gas/Drain Piping Length (Maxiu) 22 550x658x275 28 30 10~46-15~20 60 62 46 48 47 48 1~/220-230-240V/50Hz 6.35 / 9.52 / 18 15

FTXS-F / RXS-F Wall Mounted Unit Flat front panel: its stylish appearance blends easily within any interior décor and is ore easy to clean. Lightweight and copact Hoe leave operation saves energy during absence Moveent sensor saves power consuption in unoccupied roos Dual air discharge fl ow for better air distribution Titaniu apatite photocatalytic air purifi cation fi lter Indoor / outdoor unit silent operation ARC433A70 FTXS60,71F 5 steps RXS60,71F standard MXS HEAT PUMP INVERTER Indoor Units FTXS60FV1B FTXS71FV1B Capacity Cooling capacity Miniu kw 1,7 2,3 Standard kw 6,0 7,1 Maxiu kw 6,7 8,5 Heating capacity Miniu kw 1,7 2,3 Standard kw 7,0 8,2 Maxiu kw 8,0 10,2 EER / COP Cooling / Heating 3,02 / 3,43 3,02 / 3,22 Annual energy consuption 995 1175 cooling / heating B / B B / C Air Flow Rate Cooling High/Mediu/Low/Silent Operation ³/in Heating High/Mediu/Low/Silent Operation ³/in Sound Power Cooling Mediu dba Heating Mediu dba Sound Pressure Cooling High/Mediu/Low/Silent Operation dba Heating High/Mediu/Low/Silent Operation dba 290x1050x238 12 16,2 / 13,6 / 11,4 / 10,2 17,4 / 14,6 / 11,6 / 10,6 17,4 / 15,1 / 12,7 / 11,4 19,7 / 16,9 / 14,3 / 12,7 61 62 60 62 45 / 41 / 36 / 33 46 / 42 / 37 / 34 44 / 40 / 35 / 32 46 / 42 / 37 / 34 Outdoor Unit RXS60F2V1B RXS71FV1B Heating Min~Max CWB Sound Pressure (Standard) Cooling dba Heating dba Sound Level (Night quiet) Sound Pressure dba Piping connections Liquid (OD)/Gas/Drain Piping Length (Maxiu) 735x825x300 770x900x320 48 71-10~46-15~18 63 66 49 52 49 52 46 49 1~/220-240/220-230V/50Hz 6,35 / 12,7 / 18 6,35 / 15,9 / 18 30 23

FTYN-GX / RYN-GX Wall Mounted Unit Fits neatly on a wall Wide angle louvers provide a cofortable air fl ow throughout the entire roo 24-Hour On/Off tier Indoor unit On/Off switch Power-airfl ow fl ap Anti-corrosion treated plate type heat exchangers ARC461A3 FTYN25,35GX RYN25,35GX 3 steps standard HEAT PUMP Indoor Units Capacity Cooling capacity Standard kw Heating capacity Standard kw EER / COP Cooling / Heating Annual energy consuption cooling / heating Air Flow Rate Cooling High ³/in Sound Power Cooling High dba Heating High dba Sound Pressure Cooling High/Mediu/Low dba Heating High/Mediu/Low dba NON-INVERTER FTYN25GXV1B FTYN35GXV1B 2.5 3.21 2.85 3.58 3.25 / 3.65 3.21 / 3.61 385 500 A / A A / A 288 x 800 x 204 288 x 800 x 204 9 9 9.5 9.8 - - - - 38 / 32 / 27 38 / 24 / 29 38 / 33 / 27 40 / 35 / 29 Outdoor Unit Heating Min~Max CWB Sound Pressure (High) Cooling dba Heating dba Piping connections Liquid (OD) /Gas / Drain Piping Length (Maxiu) RYN25GXV1B RYN35GXV1B 550 x 765 x 285 550 x 765 x 285 31 34 10~46 10~46-10~24-10~24 - - 48 49 49 50 6.35 / 9.52 / 18 6.35 / 12.7 / 18 15 15 24

FTYN-F / RYN-E Wall Mounted Unit Flat front panel: its stylish appearance blends easily within any interior décor and is ore easy to clean. Lightweight and copact Titaniu apatite photocatalytic air purifi cation fi lter Powerful ode can be selected for rapid cooling or heating Auto-swing function ensures effi cient air and teperature distribution. ARC433A72 FTYN50,60F RYN50,60E 5 steps standard 50 + 60 class HEAT PUMP NON-INVERTER Indoor Units FTYN50FV1B FTYN60FV1B Noinal Capacity Cooling capacity Standard kw 5.0 6.0 Heating capacity Standard kw 5.8 7.0 EER / COP Cooling / Heating 3.23 / 3.63 3.02 / 3.43 Annual energy consuption 775 995 cooling / heating A / A B / B Air Flow Rate Cooling High/Mediu/Low ³/in Heating High/Mediu/Low ³/in Sound Power Cooling Mediu dba Heating Mediu dba Sound Pressure Cooling High/Low dba Heating High/Low dba 290x1050x238 12 14.7 / 12.4 / 10.3 16.2 / 13.6 / 11.4 16.1 / 13.9 / 11.5 17.4 / 15.1 / 12.7 59 61 58 60 43 / 34 45 / 36 42 / 33 44 / 35 Outdoor Unit RYN50E3V1B RYN60E3V1B Heating Min~Max CWB Sound Pressure Cooling dba Heating dba Piping connections Liquid (OD)/Gas/Drain Piping Length (Maxiu) Max. internunit level difference 735x825x300 48-10.0~46.0-15~18 61.0 63.0 47.0 49.0 48.0 49.0 6.35 / 12.7 / 18 30 20.0 25

FAQ-B / RQ-B Wall Mounted Unit Fits neatly on a wall Ideal for shops, restaurants or offi ces requiring axiu fl oor space for furniture, decorations and fi ttings Auto-swing function ensures effi cient air distribution via louvers that close autoatically when the unit is switched off Autoatic ovable louver can be fi xed at any desired angle Both horizontal fl aps and front panel can easily be reoved and washed All aintenance operations can be carried out fro the front of the unit BRC1D52 BRC7E618/C510 FAQ71B RQ100B 2 steps heat pup HEAT PUMP NON-INVERTER Indoor Units FAQ71BVV1B FAQ100BVV1B Capacity Cooling capacity Standard kw 7.1 7.1 10.0 10.0 Heating capacity Standard kw 8.0 8.0 11.2 11.2 EER / COP Cooling / Heating 2.68 / 3.10 2.81 / 3.21 2.81 / 2.83 2.84 / 2.93 Annual energy consuption 1325 1265 1780 1760 cooling / heating D / D C / C C / D C / D Air Flow Rate Cooling High/Low ³/in Heating High/Low ³/in Sound Power Cooling High/Low dba Heating High/Low dba Sound Pressure Cooling High/Low dba Heating High/Low dba 290x1050x230 360x1570x200 13.0 26.0 19.0 / 15.0 23.0 / 19.0 19.0 / 15.0 23.0 / 19.0 59.0 / 53.0 61.0 / 57.0 59.0 / 53.0 61.0 / 57.0 43.0 / 37.0 45.0 / 41.0 43.0 / 37.0 45.0 / 41.0 Outdoor Unit RQ71B8V3B RQ71B8W1B RQ100B8V3B RQ100B8W1B Heating Min~Max CWB Sound Pressure (Standard) Cooling dba Piping connections Liquid (OD)/Gas/Drain Piping Length (Maxiu) Max. internunit level difference 770x900x320 1170x900x320 84 83 103 101-5.0~46.0-10.0~15.0 63.0 66.0 50.0 53.0 1~/230V/50Hz 3N~/400V/50Hz 1~/230V/50Hz 3N~/400V/50Hz 9.52 / 15.9 / 26 70 0.5 26

FAQ-B / RZQS-C Wall Mounted Unit Fits neatly on a wall Ideal for shops, restaurants or offi ces requiring axiu fl oor space for furniture, decorations and fi ttings Auto-swing function ensures effi cient air distribution via louvers that close autoatically when the unit is switched off Autoatic ovable louver can be fi xed at any desired angle Both horizontal fl aps and front panel can easily be reoved and washed All aintenance operations can be carried out fro the front of the unit BRC1D52 BRC7E618/510 FAQ71B RZQS71,100C 2 steps heat pup HEAT PUMP INVERTER Indoor Units FAQ71BVV1B FAQ100BVV1B Capacity Cooling capacity Standard kw 7.1 10.0 Heating capacity Standard kw 8.0 11.2 EER / COP Cooling / Heating 2.81 / 3.07 2.45 / 3.00 Annual energy consuption 1,265 2,040 cooling / heating C / D E / D Air Flow Rate Cooling High/Low ³/in Heating High/Low ³/in Sound Power Cooling High/Low dba Heating High/Low dba Sound Pressure Cooling High/Low dba Heating High/Low dba 290x1050x230 360x1570x200 13.0 26.0 19.0 / 15.0 23.0 / 19.0 19.0 / 15.0 23.0 / 19.0 59.0 / 53.0 61.0 / 57.0 59.0 / 53.0 61.0 / 57.0 43.0 / 37.0 45.0 / 41.0 43.0 / 37.0 45.0 / 41.0 220-240V/50Hz Outdoor Unit RZQS71C7V1B RZQS100C7V1B Heating Min~Max CWB Sound Pressure (Standard) Cooling dba Heating dba Sound Level (Night quiet) Sound Pressure dba Piping connections Liquid (OD)/Gas/Drain Piping Length (Maxiu) Max. internunit level difference 770x900x320 700x900x320 68-5~46-15~15.5 65 67 49 51 51 55 47 49 220-240V/50Hz 9.52 / 15.9 / 26 30 50 0.5 27

FAQ-B / RZQ-C Wall Mounted Unit Fits neatly on a wall Ideal for shops, restaurants or offi ces requiring axiu fl oor space for furniture, decorations and fi ttings Auto-swing function ensures effi cient air distribution via louvers that close autoatically when the unit is switched off Autoatic ovable louver can be fi xed at any desired angle Both horizontal fl aps and front panel can easily be reoved and washed All aintenance operations can be carried out fro the front of the unit BRC1D52 BRC7E618 FAQ71B RZQ71C 2 steps heat pup HEAT PUMP INVERTER Indoor Units FAQ71BVV1B FAQ100BVV1B Capacity Cooling capacity Standard kw 7.1 10 Heating capacity Standard kw 8.0 11.2 EER / COP Cooling / Heating 3.01 / 3.31 2.9 / 3.43 Annual energy consuption 1,180 1725 cooling / heating B / C C / B Air Flow Rate Cooling High/Low ³/in Heating High/Low ³/in Sound Power Cooling High/Low dba Heating High/Low dba Sound Pressure Cooling High/Low dba Heating High/Low dba 290x1050x230 360x1570x200 13.0 26.0 19.0 / 15.0 23.0 / 19.0 19.0 / 15.0 23.0 / 19.0 59.0 / 53.0 61.0 / 57.0 59.0 / 53.0 61.0 / 57.0 43.0 / 37.0 45.0 / 41.0 43.0 / 37.0 45.0 / 41.0 220-240V/50Hz Outdoor Unit RZQ71C7V1B RZQ100C7V1B Heating Min~Max CWB Sound Pressure (Standard) Cooling dba Heating dba Sound Level (Night quiet) Sound Pressure dba Piping connections Liquid (OD)/Gas/Drain Piping Length (Maxiu) Max. internunit level difference 770x900x320 1170x900x320 67 103-15.0~50.0-20.0~15.5 63 65 47 49 49 51 43 45 220-240V/50Hz 9.52 / 15.9 / 26 50 75 0.5 28

FAQ-B / RZQ-BW1 Wall Mounted Unit Fits neatly on a wall Ideal for shops, restaurants or offi ces requiring axiu fl oor space for furniture, decorations and fi ttings Auto-swing function ensures effi cient air distribution via louvers that close autoatically when the unit is switched off Autoatic ovable louver can be fi xed at any desired angle Both horizontal fl aps and front panel can easily be reoved and washed All aintenance operations can be carried out fro the front of the unit BRC1D52 BRC7E618/C510 FAQ71B RZQ100B 2 steps heat pup HEAT PUMP INVERTER Indoor Units FAQ100BVV1B Capacity Cooling capacity Standard kw 10.00 Heating capacity Standard kw 11.20 EER / COP Cooling / Heating 3.60 / 3.30 Annual energy consuption 1390 cooling / heating A / C Air Flow Rate Cooling High/Low ³/in Heating High/Low ³/in Sound Power Cooling High/Low dba Heating High/Low dba Sound Pressure Cooling High/Low dba Heating High/Low dba 360x1570x200 26.0 23.0 / 19.0 23.0 / 19.0 61.0 / 57.0 61.0 / 57.0 45.0 / 41.0 45.0 / 41.0 220-240V/50Hz Outdoor Unit RZQ100B8W1B Heating Min~Max CWB Sound Pressure (Standard) Cooling dba Heating dba Sound Level (Night quiet) Sound Pressure dba Piping connections Liquid (OD)/Gas/Drain Piping Length (Maxiu) Max. internunit level difference 1345x900x320 106-15.0~50.0-20.0~15.5 65.0 49.0 51.0 45.0 400V/50Hz 9.52 / 15.9 / 26 75 0.5 29

FTXS-G / RKS-G Wall Mounted Unit 2 area intelligent eye: air fl ow is sent to the area in a roo where no person is detected Energy saving during stand by ode: reduction of energy fro 10W to 2W Weekly tier: allows to progra the unit on a weekly basis Flat front panel: its stylish appearance blends easily within any interior décor and is ore easy to clean. Cofort ode reassures draught free operation 3D air fl ow Dual air discharge fl ow for better air distribution Consues up to 30% less energy than noninverter units ECONO ode decreases power consuption so that other appliances that need large power supply can be used Indoor / outdoor unit silent operation Powerful ode can be selected for rapid cooling or heating Reaches set teperature ore quickly Titaniu apatite photocatalytic air purifi cation fi lter absorbs icroscopic particles, decoposes odours and even deactivates bacteria and viruses ARC452A3 FTXS20,25,35,42,50G RKS20,25,35,42G 5 steps standard (integrated titaniu apatite) COOLING ONLY INVERTER Indoor Units FTXS20G2V1B FTXS25G2V1B FTXS35G2V1B FTXS42G2V1B FTXS50G2V1B Capacity Cooling capacity Miniu kw 1.3 1.3 1.4 1.7 1.7 Standard kw 2.0 2.5 3.5 4.2 5.0 Maxiu kw 2.8 3.2 4.0 5.0 5.3 EER Noinal 4.26 4.55 4.02 3.44 3.29 Annual energy consuption 235 275 435 610 760 cooling A A A A A Air Flow Rate Cooling High ³/in Sound Power Cooling High dba Heating High dba Sound Pressure Cooling High/Mediu/Low/Silent Operation dba 295x800x215 295x800x215 295x800x215 295x800x215 295x800x215 9 9 10 10 10 9.0 9.0 10.1 9.8 10.2 54 54 57 58 59 54 55 57 58 60 38 / 32 / 25 / 22 38 / 32 / 25 / 22 42 / 34 / 26 / 23 42 / 38 / 33 / 30 43 / 39 / 34 / 31 Outdoor Unit RKS20G2V1B RKS25G2V1B RKS35G2V1B RKS42G2V1B RKS50G2V1B Sound Pressure (Low) Cooling dba Sound Pressure (High) Cooling dba Piping connections Liquid (OD)/Gas/Drain Piping Length (Maxiu) 550x765x285 550x765x285 550x765x285 550x765x285 735x825x300 34 34 34 39 48-10~46-10~46-10~46-10~46-10~46 61 61 62 61 61 43 43 44 44 44 46 46 48 48 48 6.35 / 9.52 / 18 6.35 / 9.52 / 18 6.35 / 9.52 / 18 6.35 / 9.52 / 18 6.35 / 12.7 / 18 20 20 20 20 30 30

FTK-GV / RK-GV Wall Mounted Unit Flat front panel: its stylish appearance blends easily within any interior décor and is ore easy to clean. Lightweight and copact Consues up to 30% less energy than noninverter units Dual air discharge fl ow for better air distribution ECONO ode decreases power consuption so that other appliances that need large power supply can be used Indoor unit On/Off switch Indoor unit silent operation Powerful ode can be selected for rapid cooling Titaniu apatite photocatalytic air purifi cation fi lter Anticorrosion treatent of outdoor heat exchanger fi n Energy saving during stand by ode: reduction of energy fro 10W to 2W ARC433A87 FTK20,25,35GV RK20,25,35GV 5 steps standard COOLING ONLY INVERTER Indoor Units FTK20GV1B FTK25GV1B FTK35GV1B Capacity Cooling capacity Miniu kw 1.3 Standard kw 2.0 2.5 3.2 Maxiu kw 2.6 3.0 3.8 EER Noinal 3.62 3.38 3.37 Annual energy consuption 275 370 475 cooling A Air Flow Rate Cooling High/Mediu/Low/Silent Operation ³/in Sound Power Cooling High dba Sound Pressure Cooling High/Mediu/Low/Silent Operation dba 283x770x198 7 9.1 / 7.4 / 5.9 / 4.7 9.2 / 7.6 / 6.0 / 4.8 9.3 / 7.7 / 6.1 / 4.9 55 56 57 39 / 33 / 25 / 22 40 / 33 / 26 / 22 41 / 34 / 27 / 23 1~/220-230-240V/50Hz Outdoor Unit RK20GV1B RK25GV1B RK35GV1B Sound Pressure (High) Cooling dba Piping connections Liquid (OD)/Gas/Drain Piping Length (Maxiu) 31 550x658x275 28 30 10~46 60 62 46 48 1~/220-230-240V/50Hz 6.35 / 9.52 / 18 15

FTKS-F / RKS-F Wall Mounted Unit Flat front panel: its stylish appearance blends easily within any interior décor and is ore easy to clean. Lightweight and copact Hoe leave operation saves energy during absence Moveent sensor saves power consuption in unoccupied roos Dual air discharge fl ow for better air distribution Titaniu apatite photocatalytic air purifi cation fi lter Indoor / outdoor unit silent operation ARC433A70 FTKS60,71F 5 steps RKS60,71F standard MKS COOLING ONLY INVERTER Indoor Units FTKS60FV1B FTKS71FV1B Capacity Cooling capacity Miniu kw 1.7 2.3 Standard kw 6.0 7.1 Maxiu kw 6.7 8.5 EER Noinal 3.02 3.02 Annual energy consuption cooling Air Flow Rate Cooling High/Mediu/Low/Silent Operation ³/in Sound Power Cooling Mediu dba Sound Pressure Cooling High/Mediu/Low/Silent Operation dba 995 1175 B B 290x1050x238 290x1050x238 12 12 16.2 / 13.6 / 11.4 / 10.2 17.4 / 14.6 / 11.6 / 10.6 61 62 45 / 41 / 36 / 33 46 / 42 / 37 / 34 1- / 220-240V / 50Hz 1- / 220-240V / 50Hz Outdoor Unit RKS60FV1B RKS71FV1B 735x825x300 770x900x320 47 71 49 / 46 52 / 46 63 66 Sound Pressure (Standard) Cooling dba -10-46 -10-46 Sound Level (Night quiet) Sound Pressure dba 1-/220-240V/50Hz 1-/220-240V/50Hz 6.35 / 12.7 / 18 6.35 / 15.9 / 18 Piping connections Liquid (OD)/Gas/Drain 30 30 Piping Length (Maxiu) 20 20 32

FTN-F / RN-E Wall Mounted Unit Flat front panel: its stylish appearance blends easily within any interior décor and is ore easy to clean, Lightweight and copact Titaniu apatite photocatalytic air purifi cation fi lter Powerful ode can be selected for rapid cooling Auto-swing function ensures effi cient air and teperature distribution, ARC433A72 FTN50,60F RN50,60E 5 steps standard 50 + 60 class COOLING ONLY Indoor Units Noinal Capacity Cooling capacity Standard kw Miniu Maxiu EER Noinal Annual energy consuption Cooling Air Flow Rate Cooling High/Mediu/Low ³/in Sound Power Cooling Mediu dba Sound Pressure Cooling High/Low dba NON-INVERTER FTN50FV1B FTN60FV1B 5.0 6.0 - - - - 3.23 3.02 775 995 A B 290x1050x238 290x1050x238 12 12 14.7 / 12.4 / 10.3 16.2 / 13.6 / 11.4 59 61 43 / 34 45 / 36 Outdoor Unit Sound Pressure Cooling dba Piping connections Liquid (OD)/Gas/Drain Piping Length (Maxiu) Max. internunit level difference RN50E3V1B RN60E3V1B 735x825x300 735x825x300 47 47 47 49 61 63-10.0~46.0-10.0~46.0 6.35 / 12.7 / 18 6.35 / 12.7 / 18 30 30 20.0 20.0 33

FAQ-B / RR-B Wall Mounted Unit Fits neatly on a wall Ideal for shops, restaurants or offi ces requiring axiu fl oor space for furniture, decorations and fi ttings Auto-swing function ensures effi cient air distribution via louvers that close autoatically when the unit is switched off Autoatic ovable louver can be fi xed at any desired angle Both horizontal fl aps and front panel can easily be reoved and washed All aintenance operations can be carried out fro the front of the unit BRC1D52 BRC7E619/C511 FAQ71B RR100B 2 steps COOLING ONLY NON-INVERTER Indoor Units FAQ71BVV1B FAQ100BVV1B Capacity Cooling capacity Standard kw 7.10 7.10 10.00 10.00 EER Noinal 2.68 2.81 2.81 2.84 Annual energy consuption 1325 1265 1780 1760 cooling D C C C Air Flow Rate Cooling High/Low ³/in Sound Power Cooling High/Low dba Heating High/Low dba Sound Pressure Cooling High/Low dba 290x1050x230 360x1570x200 13.0 26.0 19.0 / 15.0 23.0 / 19.0 59.0 / 53.0 61.0 / 57.0 59.0 / 53.0 61.0 / 57.0 43.0 / 37.0 45.0 / 41.0 Outdoor Unit RR71B8V3B RR71B8W1B RR100B8V3B RR100B8W1B Sound Pressure (Standard) Cooling dba Piping connections Liquid (OD)/Gas/Drain Piping Length (Maxiu) Max. internunit level difference 770x900x320 1170x900x320 83 81 102 99-15.0~46.0 63.0 66.0 50.0 53.0 1~/230V/50Hz 3N~/400V/50Hz 1~/230V/50Hz 3N~/400V/50Hz 9.52 / 15.9 / 26 70 0.5 34

35

FLXS-B / RXS-G Flexi Unit ARC433A6 FLXS25,35,50B RXS25,35G Can fi t on either ceiling or lower wall. Its low height enables it to fi t beneath a window Consues up to 30% less energy than noninverter units Washable front panel Reaches set teperature ore quickly Auto-swing function ensures effi cient air and teperature distribution. Hoe leave operation saves energy during absence Air purifi cation fi lter Powerful ode can be selected for rapid cooling or heating Indoor / outdoor unit silent operation MXS standard 5 steps HEAT PUMP Indoor Units Capacity Cooling capacity Miniu kw Standard kw Maxiu kw Heating capacity Miniu kw Standard kw Maxiu kw EER / COP Cooling / Heating Annual energy consuption cooling / heating Air Flow Rate Cooling High/Mediu/Low/Silent Operation ³/in Heating High/Mediu/Low/Silent Operation ³/in Sound Power Cooling High dba Heating High dba Sound Pressure Cooling High/Mediu/Low/Silent Operation dba Heating High/Mediu/Low/Silent Operation dba INVERTER FLXS25BAVMB FLXS35BAVMB FLXS50BAVMB 1.2 1.2 0.9 2.5 3.5 4.9 3.0 3.8 5.3 1.2 1.2 0.9 3.4 4.0 6.1 4.5 5.0 7.5 3.85 / 3.47 3.10 / 3.25 2.85 / 3.35 325 565 860 A / B B / C C / C 490x1050x200 490x1050x200 490x1050x200 16.0 16.0 17.0 7.60 / 6.80 / 6.00 / 5.2 8.60 / 7.60 / 6.60 / 5.6 11.40 / 10.00 / 8.50 / 7.6 9.20 / 8.30 / 7.40 / 6.6 9.80 / 8.90 / 8.00 / 7.2 12.1 / 9.8 / 7.5 / 6.8 53.0 54.0 63.0 - - 62.0 37.0 / 34.0 / 31.0 / 28.0 38.0 / 35.0 / 32.0 / 29.0 47.0 / 43.0 / 39.0 / 36.0 37.0 / 34.0 / 31.0 / 29.0 39.0 / 36.0 / 33.0 / 30.0 46.0 / 41.0 / 35.0 / 33.0 1~/220-240/220-230V/50/60Hz 1~/220-240/220-230V/50/60Hz 1~/220-240/220-230V/50/60Hz Outdoor Unit Heating Min~Max CWB Sound Pressure (Low) Cooling dba Heating dba Sound Pressure (High) Cooling dba Heating dba Piping connections Liquid (OD)/Gas/Drain Piping Length (Maxiu) RXS25G2V1B RXS35G2V1B RXS50G2V1B 550x765x285 550x765x285 735x825x300 34 34 48-10~46-10~46-10~46-15~20-15~20-15~18 61 63 62 43 44 44 44 45 45 46 48 48 47 48 48 6.35 / 9.52/18 6.35 / 9.52/18 6.35 / 12.7/18 20 20 30 36

FLKS-B / RKS-G Flexi Unit Can fi t on either ceiling or lower wall. Its low height enables it to fi t beneath a window Consues up to 30% less energy than noninverter units Washable front panel Reaches set teperature ore quickly Auto-swing function ensures effi cient air and teperature distribution. Hoe leave operation saves energy during absence Air purifi cation fi lter Powerful ode can be selected for rapid cooling Indoor / outdoor unit silent operation ARC433A6 FLKS25,35,50B RKS25,35G standard 5 steps MKS COOLING ONLY INVERTER Indoor Units FLKS25BAVMB FLKS35BAVMB FLKS50BAVMB Capacity Cooling capacity Miniu kw Standard kw Maxiu kw EER Noinal Annual energy consuption cooling Air Flow Rate Cooling High/Mediu/Low/Silent Operation ³/in Sound Power Cooling High dba Sound Pressure Cooling High/Mediu/Low/Silent Operation dba 1.2 1.2 0.9 2.5 3.5 4.9 3.0 3.8 5.3 3.85 3.70 2.85 325 565 860 A B C 490x1050x200 490x1050x200 490x1050x200 16.0 16.0 17.0 7.60 / 6.80 / 6.00 / 5.2 8.60 / 7.60 / 6.6 / 5.6 11.40 / 10.00 / 8.50 / 7.5 53.0 54.0 63.0 37.0 / 34.0 / 31.0 / 28.0 38.0 / 35.0 / 32.0 / 29.0 47.0 / 43.0 / 39.0 / 36.0 1~/220-240/220-230V/50/60Hz 1~/220-240/220-230V/50/60Hz 1~/220-240/220-230V/50/60Hz Outdoor Unit RKS25G2V1B RKS35G2V1B RKS50G2V1B Sound Pressure (Low) Cooling dba Sound Pressure (High) Cooling dba Piping connections Liquid (OD)/Gas/Drain Piping Length (Maxiu) 550x765x285 550x765x285 735x825x300 34 34 48-10~46-10~46-10~46 61 63 62 43 44 44 46 48 48 6.35 / 9.52 / 18 6.35 / 9.52 / 18 6.35 / 12.7 / 18 20 20 30 37

FLKS-B / RN-E Flexi Unit Can fi t on either ceiling or lower wall. Its low height enables it to fi t beneath a window Consues up to 30% less energy than noninverter units Washable front panel Reaches set teperature ore quickly Auto-swing function ensures effi cient air and teperature distribution. Hoe leave operation saves energy during absence Air purifi cation fi lter Powerful ode can be selected for rapid cooling Indoor / outdoor unit silent operation ARC433A6 FLKS50B FLKS50B RN50E standard 5 steps MKS COOLING ONLY Indoor Units Noinal Capacity Cooling capacity Standard kw EER Noinal Annual energy consuption cooling Air Flow Rate Cooling High/Mediu/Low/Silent Operation ³/in Sound Power Cooling High dba Sound Pressure Cooling High/Mediu/Low/Silent Operation dba NON-INVERTER FLKS50BAVMB 4.9 2.85 860 C 490x1050x200 17.0 11.40 / 10.00 / 8.50 / 7.5 63.0 47.0 / 43.0 / 39.0 / 36.0 1~/220-240/220-230V/50/60Hz Outdoor Unit Sound Pressure Cooling dba Piping connections Liquid (OD)/Gas/Drain Piping Length (Maxiu) Max. internunit level difference RN50E3V1B 735x825x300 47-10.0~46.0 61.0 47.0 6.35 / 12.7 / 18 30 20.0 38

FVXS-F / RXS-G Floor Standing Unit Weekly tier: allows to progra the unit on a weekly basis Stylish design Flat front panel: its stylish appearance blends easily within any interior décor and is ore easy to clean. Titaniu apatite photocatalytic air purifi cation fi lter Can be installed against a wall or recessed Dual air discharge fl ow for better air distribution ECONO ode decreases power consuption so that other appliances that need large power supply can be used Lightweight but sturdy design ARC452A1 FVXS25,35,50FV1B RXS25,35G 5 steps standard Titaniu apatite photocatalytic air purifi cation fi lter HEAT PUMP INVERTER Indoor Units FVXS25FV1B FVXS35FV1B FVXS50FV1B Capacity Cooling capacity Miniu kw Standard kw Maxiu kw Heating capacity Miniu kw Standard kw Maxiu kw EER / COP Cooling / Heating Annual energy consuption cooling / heating Air Flow Rate Cooling High/Mediu/Low/Silent Operation ³/in Heating High/Mediu/Low/Silent Operation ³/in Sound Power Cooling High dba Heating High dba Sound Pressure Cooling High/Mediu/Low/Silent Operation dba Heating High/Mediu/Low/Silent Operation dba 1.3 1.4 1.4 2.5 3.5 5.0 3.0 3.8 5.6 1.3 1.4 1.4 3.4 4.5 5.8 4.5 5.0 8.1 4.39 / 4.30 3.43 / 3.69 3.23 / 3.63 285 510 775 A / A A / A A / A 600x700x210 600x700x210 600x700x210 14 14 14 8.2 / 6.5 / 4.8 / 4.1 8.5 / 6.7 / 4.9 / 4.5 10.7 / 9.2 / 7.8 / 6.6 8.8 / 6.9 / 5.0 / 4.4 9.4 / 7.3 / 5.2 / 4.7 11.8 / 10.1 / 8.5 / 7.1 54 55 56 54 55 57 38 / 32 / 26 / 23 39 / 33 / 27 / 24 44 / 40 / 36 / 32 38 / 32 / 26 / 23 39 / 33 / 27 / 24 45 / 40 / 36 / 32 Outdoor Unit RXS25G2V1B RXS35G2V1B RXS50G2V1B Heating Min~Max CWB Sound Pressure (Low) Cooling dba Heating dba Sound Pressure (High) Cooling dba Heating dba Piping connections Liquid (OD)/Gas/Drain Piping Length (Maxiu) 550x765x285 550x765x285 735x825x300 34 34 48-10~46-10~46-10~46-15~20-15~20-15~18 61 63 62 43 44 44 44 45 45 46 48 48 47 48 48 6.35 / 9.52/18 6.35 / 9.52/18 6.35 / 12.7/18 20 20 30 39

FVXS-F / RKS-G Floor Standing Unit Weekly tier: allows to progra the unit on a weekly basis Stylish design Flat front panel: its stylish appearance blends easily within any interior décor and is ore easy to clean. Titaniu apatite photocatalytic air purifi cation fi lter Can be installed against a wall or recessed Dual air discharge fl ow for better air distribution ECONO ode decreases power consuption so that other appliances that need large power supply can be used Lightweight but sturdy design ARC452A1 FVXS25,35,50F RKS25,35G 5 steps standard Titaniu apatite photocatalytic air purifi cation fi lter COOLING ONLY INVERTER Indoor Units FVXS25FV1B FVXS35FV1B FVXS50FV1B Capacity Cooling capacity Miniu kw Standard kw Maxiu kw EER Noinal Annual energy consuption cooling Air Flow Rate Cooling High/Mediu/Low/Silent Operation ³/in Sound Power Cooling High dba Sound Pressure Cooling High/Mediu/Low/Silent Operation dba 1.3 1.4 1.4 2.5 3.5 5.0 3.0 3.8 5.6 4.39 3.43 3.23 285 510 775 A A A 600x700x210 600x700x210 600x700x210 14 14 14 8.2 / 6.5 / 4.8 / 4.1 8.5 / 6.7 / 4.9 / 4.5 10.7 / 9.2 / 7.8 / 6.6 54 55 56 38 / 32 / 26 / 23 39 / 33 / 27 / 24 44 / 40 / 36 / 32 Outdoor Unit RKS25G2V1B RKS35G2V1B RKS50G2V1B Sound Pressure (Low) Cooling dba Sound Pressure (High) Cooling dba Piping connections Liquid (OD)/Gas/Drain Piping Length (Maxiu) 550x765x285 550x765x285 735x825x300 34 34 48-10~46-10~46-10~46 61 63 62 43 44 44 46 48 48 6.35 / 9.52 / 18 6.35 / 9.52 / 18 6.35 / 12.7 / 18 20 20 30 40

FVQ-B / RZQS-C Floor Standing Unit Ideal solution for shops, restaurants or offi ces without false ceilings Very effi cient for use in roos with high ceilings Quiet operation: down to 35 dba sound pressure level (71 class) Auto-swing function ensures effi cient air and teperature distribution. FVQ-B RZQS125C 2 steps HEAT PUMP INVERTER Indoor Units FVQ71BV1B FVQ100BV1B FVQ125BV1B Capacity Cooling capacity Standard kw Heating capacity Standard kw EER / COP Cooling / Heating Annual energy consuption cooling / heating Sound Power Cooling High/Low dba Heating High/Low dba Sound Pressure Cooling High/Low dba Heating High/Low dba 7.1 10 12.5 8 11.2 14 2.81 / 3.21 2.49 / 2.81 2.81 / 3.21 1,265 2,010 2,225 C / C E / D C / C 1,850 x 600 x 270 1,850 x 600 x 350 1,850 x 600 x 350 39 46 47 54 / 48 60 / 54 62 / 56 54 / 48 60 / 54 62 / 56 42 / 36 48 / 42 50 / 44 42 / 36 48 / 42 50 / 44 1~ / 220-240V / 50Hz 1~ / 220-240V / 50Hz 1~ / 220-240V / 50Hz Outdoor Unit RZQS71C7V1B RZQS100C7V1B RZQS125C7V1B Heating Min~Max CWB Sound Pressure (Standard) Cooling dba Heating dba Sound Level (Night quiet) Sound Pressure dba Piping connections Liquid (OD)/Gas/Drain Piping Length (Maxiu) Max. internunit level difference 770 x 900 x 320 700 x 900 x 320 1,170 x 900 x 320 68 103-5~46-15~15.5 65 67 49 51 51 55 53 47 49 220-240V/50Hz 9.52 / 15.9 / 26 30 50 0.5 41

FDXS-E / RXS-G Sli Concealed Ceiling Unit Sli design for fl exible installation Copact diensions, can easily be ounted in a ceiling void Blends unobtrusively with any interior décor Can be installed in both new and existing buildings. Leaves axiu fl oor and wall space for furniture, decorations and fi ttings Powerful ode can be selected for rapid cooling or heating ARC433A8 FDXS25,35E Hoe leave operation saves energy during absence Standard suction fi lter: reoves airborne dust particles to ensure a steady supply of clean air Indoor / outdoor unit silent operation: "Silent" buttons on the reote control lower the operation sound of the indoor and/or outdoor unit by 3dB(A). Mediu external static pressure facilitates unit use with fl exible ducts of varying lengths RXS25,35G 5 steps standard HEAT PUMP INVERTER Indoor Units FDXS25EAVMB FDXS35EAVMB Capacity Cooling capacity Miniu kw Standard kw Maxiu kw Heating capacity Miniu kw Standard kw Maxiu kw EER / COP Cooling / Heating Annual energy consuption cooling / heating Air Flow Rate Cooling High/Mediu/Low/Silent Operation ³/in Heating High/Mediu/Low/Silent Operation ³/in Sound Power Cooling High dba Heating High dba Sound Pressure Cooling High/Mediu/Low/Silent Operation dba Heating High/Mediu/Low/Silent Operation dba 1.3 1.4 2.4 3.4 3.0 3.8 1.3 1.4 3.2 4.0 4.5 5.0 3.48 / 3.52 3.12 / 3.39 345 545 A / B B / C 200x700x620 200x700x620 21.0 21.0 8.7 / 8.0 / 7.3 / 6.2 8.7 / 8.0 / 7.3 / 6.2 8.7 / 8.0 / 7.3 / 6.2 8.7 / 8.0 / 7.3 / 6.2 53.0 53.0 53.0 53.0 35.0 / 33.0 / 31.0 / 29.0 35.0 / 33.0 / 31.0 / 29.0 35.0 / 33.0 / 31.0 / 29.0 35.0 / 33.0 / 31.0 / 29.0 1~/220-240/220-230V/50/60Hz 1~/220-240/220-230V/50/60Hz Outdoor Unit RXS25G2V1B RXS35G2V1B Heating Min~Max CWB Sound Pressure (Low) Cooling dba Heating dba Sound Pressure (High) Cooling dba Heating dba Piping connections Liquid (OD)/Gas/Drain Piping Length (Maxiu) 550x765x285 550x765x285 34 34-10~46-10~46-15~20-15~20 61 63 43 44 44 45 46 48 47 48 6.35 / 9.52/18 6.35 / 9.52/18 20 20 42

FDXS-C / RXS-G Sli Concealed Ceiling Unit Sli design for fl exible installation Copact diensions, can easily be ounted in a ceiling void Blends unobtrusively with any interior décor Can be installed in both new and existing buildings. Leaves axiu fl oor and wall space for furniture, decorations and fi ttings Powerful ode can be selected for rapid cooling or heating Hoe leave operation saves energy during absence Standard suction fi lter: reoves airborne dust particles to ensure a steady supply of clean air Indoor / outdoor unit silent operation: "Silent" buttons on the reote control lower the operation sound of the indoor and/or outdoor unit by 3dB(A). Mediu external static pressure facilitates unit use with fl exible ducts of varying lengths ARC433A8 FDXS50C RXS50G 5 steps standard HEAT PUMP INVERTER Indoor Units Capacity Cooling capacity Miniu kw Standard kw Maxiu kw Heating capacity Miniu kw Standard kw Maxiu kw EER / COP Cooling / Heating Annual energy consuption cooling / heating Air Flow Rate Cooling High/Mediu/Low/Silent Operation ³/in Heating High/Mediu/Low/Silent Operation ³/in Sound Power Cooling High dba Heating High dba Sound Pressure Cooling High/Mediu/Low/Silent Operation dba Heating High/Mediu/Low/Silent Operation dba FDXS50CVMB 1.7 5.0 5.3 1.7 5.8 6.0 3.03 / 3.02 825 B / D 200x900x620 27.0 12.0 / 11.0 / 10.0 / 8.4 12.0 / 11.0 / 10.0 / 8.4 55.0 55.0 37.0 / 35.0 / 33.0 / 31.0 37.0 / 35.0 / 33.0 / 31.0 1~/220-240/220-230V/50/60Hz Outdoor Unit Heating Min~Max CWB Sound Pressure (Low) Cooling dba Heating dba Sound Pressure (High) Cooling dba Heating dba Piping connections Liquid (OD)/Gas/Drain Piping Length (Maxiu) RXS50G2V1B 735x825x300 48-10~46-15~18 62 44 45 48 48 6.35 / 12.7/18 30 43

FDXS-C / RXS-F Sli Concealed Ceiling Unit Sli design for fl exible installation Copact diensions, can easily be ounted in a ceiling void Blends unobtrusively with any interior décor Can be installed in both new and existing buildings. Leaves axiu fl oor and wall space for furniture, decorations and fi ttings Powerful ode can be selected for rapid cooling or heating Hoe leave operation saves energy during absence Standard suction fi lter: reoves airborne dust particles to ensure a steady supply of clean air Indoor / outdoor unit silent operation: "Silent" buttons on the reote control lower the operation sound of the indoor and/or outdoor unit by 3dB(A). Mediu external static pressure facilitates unit use with fl exible ducts of varying lengths ARC433A8 FDXS60C standard MXS RXS60F 5 steps HEAT PUMP Indoor Units FDXS60CVMB Capacity Cooling capacity Miniu kw Standard kw 1.7 6.0 Maxiu kw 6.5 Heating capacity Miniu Standard kw kw 1.7 7.0 Maxiu kw 8.0 EER / COP Cooling / Heating 2.82 / 3.02 Annual energy consuption 1065 cooling / heating C / D Air Flow Rate Cooling High/Mediu/Low/Silent Operation ³/in Heating High/Mediu/Low/Silent Operation ³/in Sound Power Cooling High dba Heating High dba Sound Pressure Cooling High/Mediu/Low/Silent Operation dba Heating High/Mediu/Low/Silent Operation dba 200x1100x620 30.0 16.0 / 14.8 / 13.5 / 11.2 16.0 / 14.8 / 13.5 / 11.2 56.0 56.0 38.0 / 36.0 / 34.0 / 32.0 38.0 / 36.0 / 34.0 / 32.0 220-240/220-230V/50/60Hz Outdoor Unit RXS60F2V1B Heating Min~Max CWB Sound Pressure (Standard) Cooling dba Heating dba Sound Level (Night quiet) Sound Pressure dba Piping connections Liquid (OD)/Gas/Drain Piping Length (Maxiu) 735x825x300 48-10~46-15~18 63 49 49 46 220-240/220-230V/50Hz 6.35 / 12.7 / 18 30 44

45

FBQ-B / RXS-G Concealed Ceiling Unit Lightweight and copact Sli design for fl exible installation Blends unobtrusively with any interior décor: only the suction and discharge grilles are visible The position of individual air discharge grilles can be altered, enabling effi cient teperature distribution, even in irregularly shaped roos. Optiu air distribution Quiet operation Maxiu external static pressure (ESP) is 88Pa BRC1D52 FBQ35,50B standard 2 steps RXS35G heat pup 35~50 HEAT PUMP Indoor Units Capacity Cooling capacity Miniu kw Standard kw Maxiu kw Heating capacity Miniu kw Standard kw Maxiu kw EER / COP Cooling / Heating Annual energy consuption cooling / heating Air Flow Rate Cooling High/Low ³/in Heating High/Low ³/in Sound Power Cooling High dba Heating High dba Sound Pressure Cooling High/Low dba Heating High/Low dba Decoration Panel Model Colour HxWxD INVERTER FBQ35B8V1 FBQ50B8V1 - - 3.4 5.0 - - - - 4.0 6.0 - - 2.91 2.60 585 960 C E 300x700x800 300x700x800 30 31 11.5 / 9 14 / 10 11.5 / 9 14 / 10 52 53 52 53 33 / 29 33 / 29 33 / 29 33 / 29 1~/230V/50Hz 1~/230V/50Hz BYBS45D BYBS45D 55x800x500 55x800x500 3.5 3.5 Outdoor Unit Heating Min~Max CWB Sound Pressure (Low) Cooling dba Heating dba Sound Pressure (High) Cooling dba Heating dba Piping connections Liquid (OD)/Gas/Drain Piping Length (Maxiu) RXS35G2V1B RXS50G2V1B 550x765x285 735x825x300 34 48-10~46-10~46-15~20-15~20 63 61 44 44 45 45 48 48 48 48 6.35 / 9.52 / 18 6.35 / 12.7 / 18 20 30 46

FBQ-B / RXS-F Concealed Ceiling Unit Lightweight and copact Sli design for fl exible installation Blends unobtrusively with any interior décor: only the suction and discharge grilles are visible The position of individual air discharge grilles can be altered, enabling effi cient teperature distribution, even in irregularly shaped roos. Optiu air distribution Quiet operation Maxiu external static pressure (ESP) is 88Pa BRC1D52 FBQ60B standard 2 steps RXS60F heat pup 35~60 HEAT PUMP Indoor Units Capacity Cooling capacity Miniu kw Standard kw Maxiu kw Heating capacity Miniu kw Standard kw Maxiu kw EER / COP Cooling / Heating Annual energy consuption cooling / heating Air Flow Rate Cooling High/Low ³/in Heating High/Low ³/in Sound Power Cooling High dba Heating High dba Sound Pressure Cooling High/Low dba Heating High/Low dba Decoration Panel Model Colour HxWxD INVERTER FBQ60B8V1-5.7 - - 7.0-2.60 / 2.80 1095 E / E 300x1000x800 41 19 / 14 19 / 14 60 60 34 / 30 34 / 30 1~/230V/50Hz BYBS71D White 55x1100x500 4.5 Outdoor Unit Heating Min~Max CWB Sound Pressure (Standard) Cooling dba Heating dba Sound Level (Night quiet) Sound Pressure dba Piping connections Liquid (OD)/Gas/Drain Piping Length (Maxiu) RXS60F2V1B 735x825x300 48-10~46-15~18 63 49 49 46 1~/220-240/220-230V/50Hz 6.35 / 12.7 / 18 30 47

FBQ-B / RQ-B Concealed Ceiling Unit Lightweight and copact Sli design for fl exible installation Blends unobtrusively with any interior décor: only the suction and discharge grilles are visible The position of individual air discharge grilles can be altered, enabling effi cient teperature distribution, even in irregularly shaped roos. Optiu air distribution Quiet operation Maxiu external static pressure (ESP) is 88Pa BRC1D52 FBQ100, 125B standard 2 steps heat pup RQ100, 125B HEAT PUMP NON-INVERTER Indoor Units FBQ71B8V3B FBQ100B8V3B FBQ125B8V3B Capacity Cooling capacity Standard kw 7.1 7.1 10.0 10.0 12.2 Heating capacity Standard kw 8.0 8.0 11.2 11.2 14.5 EER / COP Cooling / Heating 2.54 / 3.21 2.65 / 3.21 2.64 / 2.86 2.78 / 2.89 2.61 / 3.21 Annual energy consuption 1395 1340 1895 1800 2335 cooling / heating E / C D / C D / D D / D D / C Air Flow Rate Cooling High/Low ³/in Heating High/Low ³/in Sound Power Cooling High dba Sound Pressure Cooling High/Low dba Heating High/Low dba Decoration Panel Model Colour HxWxD 300x1000x800 300x1400x800 41.0 51.0 52.0 19.00 / 14.00 27.00 / 20.00 35.00 / 24.00 19.00 / 14.00 27.00 / 20.00 35.00 / 24.00 60.0 62.0 63.0 34.0 / 30.0 36.0 / 31.0 38.0 / 32.0 34.0 / 30.0 36.0 / 31.0 38.0 / 32.0 1~/230V/50Hz BYBS71DJW1 BYBS125DJW1 White 55x1100x500 55x1500x500 4.5 6.5 Outdoor Unit RQ71B8V3B RQ71B8W1B RQ100B8V3B RQ100B8W1B RQ125B8W1B Heating Min~Max CWB Sound Pressure (Standard) Cooling dba Piping connections Liquid (OD)/Gas/Drain Piping Length (Maxiu) Max. internunit level difference 770x900x320 1170x900x320 84 83 103 101 108-5.0~46.0-10.0~15.0 63.0 66.0 67.0 50.0 53.0 1~/230V/50Hz 3N~/400V/50Hz 1~/230V/50Hz 3N~/400V/50Hz 9.52 / 15.9 / 26 70 0.5 48

FBQ-B/ REQ-B* Concealed Ceiling Unit Lightweight and copact Sli design for fl exible installation Blends unobtrusively with any interior décor: only the suction and discharge grilles are visible The position of individual air discharge grilles can be altered, enabling effi cient teperature distribution, even in irregularly shaped roos. Optiu air distribution Quiet operation Maxiu external static pressure (ESP) is 88Pa BRC1D52 FBQ100,125B standard 2 steps heat pup REQ100,125B HEAT PUMP NON-INVERTER Indoor Units FBQ71B8V3B FBQ100B8V3B FBQ125B8V3B Capacity Cooling capacity Standard kw 7.1 7.1 10 10 12.20 Heating capacity Standard kw 8 8 11.2 11.2 14.5 EER / COP Cooling / Heating 2.54 / 3.21 2.65 / 3.21 2.64 / 2.86 2.78 / 2.89 2.61 / 3.21 Annual energy consuption 1395 1340 1895 1800 2335 cooling / heating E / C D / C D / D D / D D / C Air Flow Rate Cooling High/Low ³/in Heating High/Low ³/in Sound Power Cooling High dba Sound Pressure Cooling High/Low dba Heating High/Low dba Decoration Panel Model Colour HxWxD 300x1000x800 300x1400x800 41.0 51.0 52.0 19.00 / 14.00 27.00 / 20.00 35.00 / 24.00 19.00 / 14.00 27.00 / 20.00 35.00 / 24.00 60.0 62.0 63.0 34.0 / 30.0 36.0 / 31.0 38.0 / 32.0 34.0 / 30.0 36.0 / 31.0 38.0 / 32.0 1~/230V/50Hz BYBS71DJW1 BYBS125DJW1 White 55x1100x500 55x1500x500 4.5 6.5 Outdoor Unit REQ71B8V3B REQ71B8W1B REQ100B8V3B REQ100B8W1B REQ125B8W1B Heating Min~Max CWB Sound Pressure (Standard) Cooling dba Piping connections Liquid (OD)/Gas/Drain Piping Length (Maxiu) Max. internunit level difference * Cobination only available in Portugal, Greece, Cyprus and Malta 770x900x320 1170x900x320 83 102 100 108 10.0~46.0-10~15 65.0 70.0 53.0 57.0 1~/230V/50Hz 3N~/400V/50Hz 1~/230V/50Hz 3N~/400V/50Hz 9.52 / 15.9 / 26 50 0.5 49

FBQ-B / RZQS-C Concealed Ceiling Unit Lightweight and copact Sli design for fl exible installation Blends unobtrusively with any interior décor: only the suction and discharge grilles are visible The position of individual air discharge grilles can be altered, enabling effi cient teperature distribution, even in irregularly shaped roos. Optiu air distribution Quiet operation Maxiu external static pressure (ESP) is 88Pa BRC1D52 FBQ100,125,140B standard 2 steps RZQS125,140C heat pup HEAT PUMP INVERTER Indoor Units FBQ71B8V3B FBQ100B8V3B FBQ125B8V3B FBQ140B8V3B Capacity Cooling capacity Standard kw 7.1 10.0 12.5 13.4 Heating capacity Standard kw 8.0 11.2 14.0 15.5 EER / COP Cooling / Heating 2.82 / 3.33 2.61 / 3.23 2.84 / 3.3 2.70 / 3.11 Annual energy consuption 1,260 1,915 2,200 2,485 cooling / heating C / C D / C C / C D / D Air Flow Rate Cooling High/Low ³/in Heating High/Low ³/in Sound Power Cooling High dba Sound Pressure Cooling High/Low dba Heating High/Low dba Decoration Panel Model Colour HxWxD 300x1000x800 300x1400x800 41.0 51.0 52.0 19.00 / 14.00 27.00 / 20.00 35.00 / 24.00 19.00 / 14.00 27.00 / 20.00 35.00 / 24.00 60.0 62.0 63.0 34.0 / 30.0 36.0 / 31.0 38.0 / 32.0 34.0 / 30.0 36.0 / 31.0 38.0 / 32.0 1~/230V/50Hz BYBS71DJW1 BYBS125DJW1 White 55x1100x500 55x1500x500 4.5 6.5 Outdoor Unit RZQS71C7V1B RZQS100C7V1B RZQS125C7V1B RZQS140C7V1B Heating Min~Max CWB Sound Pressure (Standard) Cooling dba Heating dba Sound Level (Night quiet) Sound Pressure dba Piping connections Liquid (OD)/Gas/Drain Piping Length (Maxiu) Max. internunit level difference 770x900x320 700x900x320 1,170x900x320 1170x900x320 68 103-5~46-15~15.5 65 67 68 49 51 52 51 55 53 54 47 49 50 9.52 / 15.9 / 26 30 50 0.5 50

FBQ-B / RZQ-C Concealed Ceiling Unit Lightweight and copact Sli design for fl exible installation Blends unobtrusively with any interior décor: only the suction and discharge grilles are visible The position of individual air discharge grilles can be altered, enabling effi cient teperature distribution, even in irregularly shaped roos. Optiu air distribution Quiet operation Maxiu external static pressure (ESP) is 88Pa BRC1D52 FBQ100,125,140B standard 2 steps RZQ100,125,140C heat pup HEAT PUMP INVERTER Indoor Units FBQ71B8V3B FBQ100B8V3B FBQ125B8V3B FBQ140B8V3B Capacity Cooling capacity Standard kw 7.1 10.0 12.5 13.4 Heating capacity Standard kw 8.0 11.2 14.0 15.5 EER / COP Cooling / Heating 3.21 / 3.76 3.33 / 3.75 3.14 / 3.52 2.81 / 3.21 Annual energy consuption 1,105 1500 1985 2385 cooling / heating A / A B / B C / C Air Flow Rate Cooling High/Low ³/in Heating High/Low ³/in Sound Power Cooling High dba Sound Pressure Cooling High/Low dba Heating High/Low dba Decoration Panel Model Colour HxWxD 300x1000x800 300x1400x800 41.0 51.0 52.0 19.00 / 14.00 27.00 / 20.00 35.00 / 24.00 19.00 / 14.00 27.00 / 20.00 35.00 / 24.00 60.0 62.0 63.0 34.0 / 30.0 36.0 / 31.0 38.0 / 32.0 34.0 / 30.0 36.0 / 31.0 38.0 / 32.0 1~/230V/50Hz BYBS71DJW1 BYBS125DJW1 White 55x1100x500 55x1500x500 4.5 6.5 Outdoor Unit RZQ71C7V1B RZQ100C7V1B RZQ125C7V1B RZQ140C7V1B Heating Min~Max CWB Sound Pressure (Standard) Cooling dba Heating dba Sound Level (Night quiet) Sound Pressure dba Piping connections Liquid (OD)/Gas/Drain Piping Length (Maxiu) Max. internunit level difference 770x900x320 1170x900x320 67 103-15.0~50.0-20.0~15.5 63 65 66 67 47 49 50 49 51 52 43 45 46 9.52 / 15.9 / 26 50 75 0.5 51

FBQ-B / RZQ-BW1 Concealed Ceiling Unit BRC1D52 FBQ100,125,140B RZQ100,125,140B Lightweight and copact Sli design for fl exible installation Blends unobtrusively with any interior décor: only the suction and discharge grilles are visible The position of individual air discharge grilles can be altered, enabling effi cient teperature distribution, even in irregularly shaped roos. Optiu air distribution Quiet operation Maxiu external static pressure (ESP) is 88Pa standard 2 steps heat pup HEAT PUMP INVERTER Indoor Units FBQ100B8V3B FBQ125B8V3B FBQ140B8V3B Capacity Cooling capacity Standard kw 10,00 12,50 13,40 Heating capacity Standard kw 11,20 14,00 15,50 EER / COP Cooling / Heating 3,50 / 3,73 3,14 / 3,51 2,82 / 3,21 Annual energy consuption 1430 1990 2380 cooling / heating A / A B / B C / C Air Flow Rate Cooling High/Low ³/in Heating High/Low ³/in Sound Power Cooling High dba Sound Pressure Cooling High/Low dba Heating High/Low dba Decoration Panel Model Colour HxWxD 300x1400x800 51,0 52,0 27,00 / 20,00 35,00 / 24,00 27,00 / 20,00 35,00 / 24,00 62,0 63,0 36,0 / 31,0 38,0 / 32,0 36,0 / 31,0 38,0 / 32,0 1~/230V/50Hz BYBS125DJW1 White 55x1500x500 6,5 Outdoor Unit RZQ100B8W1B RZQ125B8W1B RZQ140B8W1B Heating Min~Max CWB Sound Pressure (Standard) Cooling dba Heating dba Sound Level (Night quiet) Sound Pressure dba Piping connections Liquid (OD)/Gas/Drain Piping Length (Maxiu) Max. internunit level difference 1345x900x320 106-15,0~50,0-20,0~15,5 65,0 66,0 49,0 50,0 51,0 52,0 45,0 3N~/400V/50Hz 9,52 / 15,9 / 26 75 0,5 52

FDQ-B / RQ-B Concealed Ceiling Unit Sli design for fl exible installation Ideal for use in larger areas Blends unobtrusively with any interior décor: only the suction and discharge grilles are visible Maxiu external static pressure (ESP) ranges fro 150 till 250Pa Optiu air distribution BRC1D52 FDQ125B 2 steps: FDQ250, 3 steps: FDQ125,200 RQ125B heat pup HEAT PUMP Indoor Units Capacity Cooling capacity Standard kw Heating capacity Standard kw EER / COP Cooling / Heating Annual energy consuption cooling / heating Air Flow Rate Cooling Mediu ³/in Heating Mediu ³/in Sound Power Cooling Mediu dba Sound Pressure Cooling High dba Heating Low dba NON-INVERTER FDQ125B8V3B9 12.5 14.6 2.61 / 3.24 2395 D / C 350x1400x662 59.0 43.0 43.0 75.0 44.0 44.0 1~/230V/50Hz Outdoor Unit Heating Min~Max CWB Sound Pressure (Standard) Cooling dba Piping connections Liquid (OD)/Gas/Drain Piping Length (Maxiu) Max. internunit level difference 53 RQ125B8W1B 1170x900x320 108-5.0~46.0-10.0~15.0 67.0 53.0 3N~/400V/50Hz 9.52 / 15.9 / 26 70 0.5

FDQ-B / RZQS-C Concealed Ceiling Unit Sli design for fl exible installation Ideal for use in larger areas Blends unobtrusively with any interior décor: only the suction and discharge grilles are visible Maxiu external static pressure (ESP) ranges fro 150 till 250Pa Optiu air distribution BRC1D52 FDQ125B 2 steps: FDQ250, 3 steps: FDQ125,200 RZQS125C standard heat pup HEAT PUMP Indoor Units Capacity Cooling capacity Standard kw Heating capacity Standard kw EER / COP Cooling / Heating Annual energy consuption cooling / heating Air Flow Rate Cooling Mediu ³/in Heating Mediu ³/in Sound Power Cooling Mediu dba Sound Pressure Cooling High dba Heating Low dba INVERTER FDQ125B8V3B9 12.5 14.0 2.81 / 3.43 2,225 C / B 350x1400x662 59.0 43.0 43.0 75.0 44.0 44.0 1~/230V/50Hz Outdoor Unit Heating Min~Max CWB Sound Pressure (Standard) Cooling dba Heating dba Sound Level (Night quiet) Sound Pressure dba Piping connections Liquid (OD)/Gas/Drain Piping Length (Maxiu) Max. internunit level difference 54 RZQS125C7V1B 1,170x900x320 103-5~46-15~15.5 67 51 53 49 9.52 / 15.9 / 26 50 0.5

FDQ-B / RZQ-C Concealed Ceiling Unit Sli design for fl exible installation Ideal for use in larger areas Blends unobtrusively with any interior décor: only the suction and discharge grilles are visible Maxiu external static pressure (ESP) ranges fro 150 till 250Pa Optiu air distribution BRC1D52 FDQ-B 2 steps: FDQ250, 3 steps: FDQ125,200 RZQ125C standard heat pup HEAT PUMP Indoor Units Capacity Cooling capacity Standard kw Heating capacity Standard kw EER / COP Cooling / Heating Annual energy consuption cooling / heating Air Flow Rate Cooling Mediu ³/in Heating Mediu ³/in Sound Power Cooling Mediu dba Sound Pressure Cooling High dba Heating Low dba INVERTER FDQ125B8V3B9 12.5 14.0 3.01 / 3.81 2075 B / A 350x1400x662 59.0 43.0 43.0 75.0 44.0 44.0 1~/230V/50Hz Outdoor Unit Heating Min~Max CWB Sound Pressure (Standard) Cooling dba Heating dba Sound Level (Night quiet) Sound Pressure dba Piping connections Liquid (OD)/Gas/Drain Piping Length (Maxiu) Max. internunit level difference 55 RZQ125C7V1B 1170x900x320 103-15.0~50.0-20.0~15.5 66 50 52 45 9.52 / 15.9 / 26 75 0.5

FDQ-B / RZQ-BW1 Concealed Ceiling Unit Sli design for fl exible installation Ideal for use in larger areas Blends unobtrusively with any interior décor: only the suction and discharge grilles are visible Maxiu external static pressure (ESP) ranges fro 150 till 250Pa Optiu air distribution BRC1D52 FDQ-B 2 steps: FDQ250, 3 steps: FDQ125,200 RZQ125B heat pup standard HEAT PUMP Indoor Units Capacity Cooling capacity Standard kw Heating capacity Standard kw EER / COP Cooling / Heating Annual energy consuption cooling / heating Air Flow Rate Cooling Mediu ³/in Heating Mediu ³/in Sound Power Cooling Mediu dba Sound Pressure Cooling High dba Heating Low dba INVERTER FDQ125B8V3B9 12.50 14.00 3.01 / 3.79 2075 B / A 350x1400x662 59.0 43.0 43.0 75.0 44.0 44.0 1~/230V/50Hz Outdoor Unit Heating Min~Max CWB Sound Pressure (Standard) Cooling dba Heating dba Sound Level (Night quiet) Sound Pressure dba Piping connections Liquid (OD)/Gas/Drain Piping Length (Maxiu) Max. internunit level difference 56 RZQ125B8W1B 1345x900x320 106-15.0~50.0-20.0~15.5 66.0 50.0 52.0 45.0 3N~/400V/50Hz 9.52 / 15.9 / 26 75 0.5

57

FDEQ-B / REQ-B* Concealed Ceiling Unit Lightweight and copact Both discharge and suction ducts can be easily connected via fl anges on the unit The air fi lter is easily accessible fro underneath, even after the installation of the ducts. The fi lter can therefore be easily washed or vacuued Extreely quiet in operation. Ideal for shops, restaurants or offi ces requiring axiu fl oor space for furniture, decorations and fi ttings Maxiu external static pressure (ESP) is 100Pa BRC1D52 FDEQ125B () heat pup REQ100B (3 steps) HEAT PUMP NON-INVERTER Indoor Units FDEQ71B8V3B FDEQ100B8V3B FDEQ125B8V3B Capacity Cooling capacity Standard kw 7.1 7.1 9.8 9.8 12.50 Heating capacity Standard kw 8 8 11.2 11.2 14.60 EER / COP Cooling / Heating 2.54 / 3.21 2.65 / 3.21 2.46 / 2.81 2.49 / 2.83 2.68 / 3.23 Annual energy consuption 1395 1340 1990 1970 2335 cooling / heating E / C D / C E / D E / D D / C 279x987x750 279x1387x750 38.1 48.6 Air Flow Rate Cooling High/Low ³/in 19.0 / 14.0 27.0 / 20.0 35.0 / 24.0 Heating High/Low ³/in 19.0 / 14.0 27.0 / 20.0 35.0 / 24.0 Sound Power Cooling High dba 63.0 65.0 66.0 Sound Pressure Cooling High/Low dba 37.0 / 33.0 39.0 / 34.0 41.0 / 35.0 Heating High/Low dba 37.0 / 33.0 39.0 / 34.0 41.0 / 35.0 1~/230V/50Hz Outdoor Unit REQ71B8V3B REQ71B8W1B REQ100B8V3B REQ100B8W1B REQ125B8W1B 770x900x320 1170x900x320 83 102 100 108 10.0~46.0 Heating Min~Max CWB -10~15 65.0 70.0 Sound Pressure (Standard) Cooling dba 53.0 57.0 1~/230V/50Hz 3N~/400V/50Hz 1~/230V/50Hz 3N~/400V/50Hz Piping connections Liquid (OD)/Gas/Drain 9.52 / 15.9 / 26 Piping Length (Maxiu) 50 Max. internunit level difference 0.5 * Cobination only available in Portugal, Greece, Cyprus and Malta 58

FDKS-E / RKS-G Sli Concealed Ceiling Unit Sli design for fl exible installation Copact diensions, can easily be ounted in a ceiling void Blends unobtrusively with any interior décor Can be installed in both new and existing buildings. Leaves axiu fl oor and wall space for furniture, decorations and fi ttings Hoe leave operation saves energy during absence Standard suction fi lter: reoves airborne dust particles to ensure a steady supply of clean air Indoor / outdoor unit silent operation: "Silent" buttons on the reote control lower the operation sound of the indoor and/or outdoor unit by 3dB(A). Mediu external static pressure facilitates unit use with fl exible ducts of varying lengths Powerful ode can be selected for rapid cooling ARC433A8 FDKS25,35E RKS25,35G 5 steps standard COOLING ONLY INVERTER Indoor Units FDKS25EAVMB FDKS35EAVMB Capacity Cooling capacity Miniu kw Standard kw Maxiu kw EER Noinal Annual energy consuption cooling Air Flow Rate Cooling High/Mediu/Low/Silent Operation ³/in Sound Power Cooling High dba Sound Pressure Cooling High/Mediu/Low/Silent Operation dba 1.3 1.4 2.4 3.4 3.0 3.8 3.48 3.12 3.45 5.45 A B 200x700x620 200x700x620 21.0 21.0 8.7 / 8.0 / 7.3 / 6.2 8.7 / 8.0 / 7.3 / 6.2 53.0 53.0 35.0 / 33.0 / 31.0 / 29.0 35.0 / 33.0 / 31.0 / 29.0 1~/220-240/220-230V/50/60Hz 1~/220-240/220-230V/50/60Hz Outdoor Unit RKS25G2V1B RKS35G2V1B Sound Pressure (Low) Cooling dba Sound Pressure (High) Cooling dba Piping connections Liquid (OD)/Gas/Drain Piping Length (Maxiu) 550x765x285 550x765x285 34 34-10~46-10~46 61 63 43 44 46 48 6.35 / 9.52 / 18 6.35 / 9.52 / 18 20 20 59

FDKS-C / RKS-G Sli Concealed Ceiling Unit Sli design for fl exible installation Copact diensions, can easily be ounted in a ceiling void Blends unobtrusively with any interior décor Can be installed in both new and existing buildings. Leaves axiu fl oor and wall space for furniture, decorations and fi ttings Hoe leave operation saves energy during absence Standard suction fi lter: reoves airborne dust particles to ensure a steady supply of clean air Indoor / outdoor unit silent operation: "Silent" buttons on the reote control lower the operation sound of the indoor and/or outdoor unit by 3dB(A). Mediu external static pressure facilitates unit use with fl exible ducts of varying lengths Powerful ode can be selected for rapid cooling ARC433A8 FDKS50C RKS50G 5 steps standard COOLING ONLY INVERTER Indoor Units Capacity Cooling capacity Miniu kw Standard kw Maxiu kw EER Noinal Annual energy consuption cooling Air Flow Rate Cooling High/Mediu/Low/Silent Operation ³/in Sound Power Cooling High dba Sound Pressure Cooling High/Mediu/Low/Silent Operation dba FDKS50CVMB 1.7 5.0 5.3 3.03 8.25 B 200x900x620 27.0 12.0 / 11.0 / 10.0 / 8.4 55.0 37.0 / 35.0 / 33.0 / 31.0 1~220-240/220-230V/50/60Hz Outdoor Unit Sound Pressure (Low) Cooling dba Sound Pressure (High) Cooling dba Piping connections Liquid (OD)/Gas/Drain Piping Length (Maxiu) RKS50G2V1B 735x825x300 48-10~46 62 44 48 220-240V/50Hz 6.35 / 12.7 / 18 30 60

FDKS-C / RKS-F Sli Concealed Ceiling Unit Sli design for fl exible installation Copact diensions, can easily be ounted in a ceiling void Blends unobtrusively with any interior décor Can be installed in both new and existing buildings Leaves axiu fl oor and wall space for furniture, decorations and fi ttings Hoe leave operation saves energy during absence Standard suction fi lter: reoves airborne dust particles to ensure a steady supply of clean air Indoor / outdoor unit silent operation: "Silent" buttons on the reote control lower the operation sound of the indoor and/or outdoor unit by 3dB(A) Mediu external static pressure facilitates unit use with fl exible ducts of varying lengths Powerful ode can be selected for rapid cooling ARC433A8 FDKS60C standard RKS60F 5 steps COOLING ONLY INVERTER Indoor Units FDKS60CVMB Capacity Cooling capacity Miniu kw Standard kw 1.7 6.0 Maxiu kw 6.5 EER Noinal 2.82 Annual energy consuption 1065 cooling C Air Flow Rate Cooling High/Mediu/Low/Silent Operation ³/in Sound Power Cooling High dba Sound Pressure Cooling High/Mediu/Low/Silent Operation dba 200x1100x620 30.0 16.0 / 14.8 / 13.5 / 11.2 56.0 38.0 / 36.0 / 34.0 / 32.0 220-240/220-230V/50/60Hz Outdoor Unit RKS60F2V1B Sound Pressure (Standard) Cooling dba Piping connections Liquid (OD)/Gas/Drain Piping Length (Maxiu) 735x825x300 47-10~46 63 49(H) - 46(SL) 220-240V/50Hz 6.35 / 12.7 / 18 30 61

FBQ-B / RKS-G Concealed Ceiling Unit Lightweight and copact Sli design for fl exible installation Blends unobtrusively with any interior décor: only the suction and discharge grilles are visible The position of individual air discharge grilles can be altered, enabling effi cient teperature distribution, even in irregularly shaped roos. Optiu air distribution Quiet operation Maxiu external static pressure (ESP) is 88Pa BRC1D52 FBQ35,50B standard 2 steps RKS35G 50 COOLING ONLY INVERTER Indoor Units FBQ35B8V1 FBQ50B8V1 Capacity Cooling capacity Miniu kw Standard kw Maxiu kw EER Noinal Annual energy consuption cooling Air Flow Rate Cooling High/Low ³/in Sound Power Cooling High dba Sound Pressure Cooling High/Low dba Decoration Panel Model - - 3.4 5.0 - - 2.91 2.60 585 960 C E 300x700x800 300x700x800 30 31 11.5 / 9 14 / 10 52 53 33 / 29 33 / 29 1~/230V/50Hz 1~/230V/50Hz BYBS45D BYBS45D Colour White White HxWxD 55x800x500 55x800x500 3.5 3.5 Outdoor Unit RKS35G2V1B RKS50G2V1B Sound Pressure (Low) Cooling dba Sound Pressure (High) Cooling dba Piping connections Liquid (OD)/Gas/Drain Piping Length (Maxiu) 550x765x285 735x825x300 34 48-10~46-10~46 62 61 44 44 48 48 6.35 / 9.52/18 6.35 / 12.7/18 20 30 62

FBQ-B / RKS-F Concealed Ceiling Unit Lightweight and copact Sli design for fl exible installation Blends unobtrusively with any interior décor: only the suction and discharge grilles are visible The position of individual air discharge grilles can be altered, enabling effi cient teperature distribution, even in irregularly shaped roos. Optiu air distribution Quiet operation Maxiu external static pressure (ESP) is 88Pa BRC1D52 FBQ60B standard 2 steps RKS60F 60 COOLING ONLY INVERTER Indoor Units FBQ60B8V1 Capacity Cooling capacity Miniu kw Standard kw Maxiu kw EER Noinal Annual energy consuption - 5.7-2.60 1095 cooling Air Flow Rate Cooling High/Low ³/in Sound Power Cooling High dba Heating High dba Sound Pressure Cooling High/Low dba Decoration Panel Model Colour HxWxD E 300x1000x800 41 19 / 14 60 60 34 / 30 1~/230V/50Hz BYBS71D White 55x1100x500 4.5 Outdoor Unit RKS60F2V1B Sound Pressure (Standard) Cooling dba Piping connections Liquid (OD)/Gas/Drain Piping Length (Maxiu) 735x825x300 47-10~46 63 49(H) - 46(SL) 6.35 / 12.7 / 18 20 63

FBQ-B / RN-E Concealed Ceiling Unit Lightweight and copact Sli design for fl exible installation Blends unobtrusively with any interior décor: only the suction and discharge grilles are visible The position of individual air discharge grilles can be altered, enabling effi cient teperature distribution, even in irregularly shaped roos. Optiu air distribution Quiet operation Maxiu external static pressure (ESP) is 88Pa BRC1D52 FBQ60B standard 2 steps RN50,60E 60 COOLING ONLY NON-INVERTER Indoor Units FBQ50B8V1 FBQ60B8V1 Noinal Capacity Cooling capacity Standard kw 5.0 5.7 EER Noinal 2.60 2.60 Annual energy consuption 960 1095 cooling E E 300x700x800 300x1000x800 31 41 Air Flow Rate Cooling High/Low ³/in 14 / 10 19 / 14 Sound Power Cooling High dba 53 60 Sound Pressure Cooling High/Low dba 33 / 29 34 / 30 Decoration Panel Model Colour 1~/230V/50Hz BYBS45D White 1~/230V/50Hz BYBS71D White HxWxD 55x800x500 55x1100x500 3.5 4.5 Outdoor Unit RN50E3V1B RN60E3V1B Sound Pressure Cooling dba Piping connections Liquid (OD)/Gas/Drain Piping Length (Maxiu) Max. internunit level difference 735x825x300 735x825x300 47 47-10.0~46.0-10.0~46.0 61.0 63.0 47.0 49.0 6.35 / 12.7 / 18 6.35 / 12.7 / 18 30 30 20 20 64

FBQ-B / RR-B Concealed Ceiling Unit Lightweight and copact Sli design for fl exible installation Blends unobtrusively with any interior décor: only the suction and discharge grilles are visible The position of individual air discharge grilles can be altered, enabling effi cient teperature distribution, even in irregularly shaped roos. Optiu air distribution Quiet operation Maxiu external static pressure (ESP) is 88Pa BRC1D52 FBQ71B standard 2 steps RR71B COOLING ONLY NON-INVERTER Indoor Units FBQ71B8V3B FBQ100B8V3B FBQ125B8V3B Capacity Cooling capacity Standard kw 7.10 7.10 10.00 10.00 12.20 EER Noinal 2.54 2.65 2.64 2.78 2.61 Annual energy consuption 1395 1340 1895 1800 2335 cooling E D D D D Air Flow Rate Cooling High/Low ³/in Sound Power Cooling High dba Sound Pressure Cooling High/Low dba Decoration Panel Model Colour HxWxD 300x1000x800 300x1400x800 41.0 51.0 52.0 19.00 / 14.00 27.00 / 20.00 35.00 / 24.00 60.0 62.0 63.0 34.0 / 30.0 36.0 / 31.0 38.0 / 32.0 1~/230V/50Hz BYBS71DJW1 BYBS125DJW1 White 55x1100x500 55x1500x500 4.5 6.5 Outdoor Unit RR71B8V3B RR71B8W1B RR100B8V3B RR100B8W1B RR125B8W1B Sound Pressure (Standard) Cooling dba Piping connections Liquid (OD)/Gas/Drain Piping Length (Maxiu) Max. internunit level difference 770x900x320 1170x900x320 83 81 102 99 106-15.0~46.0 63.0 66.0 67.0 50.0 53.0 1~/230V/50Hz 3N~/400V/50Hz 1~/230V/50Hz 3N~/400V/50Hz 9.52 / 15.9 / 26 70 0.5 65

FDQ-B / RR-B Concealed Ceiling Unit Sli design for fl exible installation Ideal for use in larger areas Blends unobtrusively with any interior décor: only the suction and discharge grilles are visible Maxiu external static pressure (ESP) ranges fro 150 till 250Pa Optiu air distribution BRC1D52 FDQ125B 3 steps: FDQ125,200 RR125B COOLING ONLY Indoor Units Capacity Cooling capacity Standard kw EER Noinal Annual energy consuption cooling Air Flow Rate Cooling Mediu ³/in Sound Power Cooling Mediu dba Sound Pressure Cooling High dba NON-INVERTER FDQ125B8V3B 12.50 2.61 2395 D 350x1400x662 59.0 43.0 75.0 44.0 1~/230V/50Hz Outdoor Unit Sound Pressure (Standard) Cooling dba Piping connections Liquid (OD)/Gas/Drain Piping Length (Maxiu) Max. internunit level difference RR125B8W1B 1170x900x320 106-15.0~46.0 67.0 53.0 3N~/400V/50Hz 9.52 / 15.9 / 26 70 0.5 66

FCQ-C / RXS-G Round Flow Cassette Modern style decoration panel in white (RAL9010) 360 air discharge ensures unifor air fl ow and teperature distribution Air discharge fro the corners avoids dead zones that ay be subject to teperature differences Cofortable horizontal air discharge ensures draughtfree operation and prevents ceiling soiling 23 different air fl ow patterns possible Reduced installation height: 214 for class 35-50 Fresh air intake: up to 20 % Easy visible drain check thanks to clear drain socket BRC1D52 BRC7E63 FCQ35,50C RXS35G heat pup 2 steps standard HEAT PUMP INVERTER Indoor Units FCQ35C7VEB FCQ50C7VEB Capacity Cooling capacity Miniu kw Standard kw Maxiu kw Heating capacity Miniu kw Standard kw Maxiu kw EER / COP Cooling / heating Annual energy consuption Energy label Cooling / heating Diensions (Height x width x depth) Air fl ow rate Cooling High/low ³/in Heating High/low ³/in Sound power Cooling High dba Sound pressure Cooling High/low dba Heating High/low dba Power supply Decoration panel Model 1.4 0.9 3.4 5.0 3.7 5.6 1.4 0.9 4.2 6.0 5.0 7.0 3.58/3.41 3.55/3.70 475 705 A/B A 204x840x840 204x840x840 19 19 10.5 / 8.5 12.5 / 8.5 12.5 / 10.0 12.5 / 8.5 49 49 31 / 27 31 / 27 31 / 27 31 / 27 1~/220-240V/50/60Hz 1~/220-240V/50/60Hz BYCQ140CW1 BYCQ140CW1 Colour Pure White (RAL 9010) Pure White (RAL 9010) HxWxD 50x950x950 50x950x950 5.5 5.5 Outdoor Unit RXS35G2V1B RXS50G2V1B Heating Min~Max CWB Sound Pressure (Low) Cooling dba Heating dba Sound Pressure (High) Cooling dba Heating dba Piping connections Liquid (OD)/Gas/Drain Piping Length (Maxiu) 550x765x285 735x825x300 34 48-10~46-10~46-15~20-15~20 63 61 44 44 45 45 48 48 48 48 6.35 / 9.52/18 6.35 / 12.7/18 20 30 67

FCQ-C / RXS-F Round Flow Cassette Modern style decoration panel in white (RAL9010) 360 air discharge ensures unifor air fl ow and teperature distribution Air discharge fro the corners avoids dead zones that ay be subject to teperature differences Cofortable horizontal air discharge ensures draughtfree operation and prevents ceiling soiling 23 different air fl ow patterns possible Reduced installation height: 214 for class 60 Fresh air intake: up to 20 % Easy visible drain check thanks to clear drain socket BRC1D52 BRC7F532 FCQ60C 2 steps RXS60F heat pup standard HEAT PUMP Indoor Units Capacity Cooling capacity Miniu kw Standard kw Maxiu kw Heating capacity Miniu kw Standard kw Maxiu kw EER / COP Cooling / Heating Annual energy consuption cooling / heating Air Flow Rate Cooling High/Low ³/in Heating High/Low ³/in Sound Power Cooling High dba Sound Pressure Cooling High/Low dba Heating High/Low dba Decoration Panel Model INVERTER FCQ60C7VEB 0.9 5.7 6.0 0.9 7.0 8.0 3.48 / 3.52 820 A / B 204x840x840 19 13.5 / 8.5 13.5 / 8.5 51 33 / 28 33 / 28 1~/220-240V/50/60Hz BYCQ140CW1 Colour Pure White (RAL 9010) HxWxD 50x950x950 5.5 Outdoor Unit Heating Min~Max CWB Sound Pressure (Standard) Cooling dba Heating dba Sound Level (Night quiet) Sound Pressure dba Piping connections Liquid (OD)/Gas/Drain Piping Length (Maxiu) RXS60F2V1B 735x825x300 48-10~46-15~18 63 49 49 46 1~/220-240/220-230V/50Hz 6.35 / 12.7 / 18 30 68

FCQ-C / RQ-B Round Flow Cassette Modern style decoration panel in white (RAL9010) 360 air discharge ensures unifor air fl ow and teperature distribution Air discharge fro the corners avoids dead zones that ay be subject to teperature differences Cofortable horizontal air discharge ensures draughtfree operation and prevents ceiling soiling 23 different air fl ow patterns possible Fresh air intake: up to 20 % Reduced installation height: 214 for class 71 Easy visible drain check thanks to clear drain socket BRC1D52 BRC7F532 FCQ100,125C heat pup 2 steps RQ100B standard HEAT PUMP NON-INVERTER Indoor Units FCQ71C7VEB FCQ100C7VEB FCQ125C7VEB Capacity Cooling capacity Standard kw 7.1 7.1 10.0 10.0 12.5 Heating capacity Standard kw 8.0 8.0 11.2 11.2 14.6 EER / COP Cooling / Heating 2.61 / 2.81 2.67 / 2.86 2.61 / 2.99 2.81 / 3.06 2.68 / 2.89 Annual energy consuption 1360 1330 1915 1780 2330 cooling / heating D / D D / D D / D C / D D / D 204x840x840 246x840x840 21 23 Air Flow Rate Cooling High/Low ³/in 15.5 / 9.0 23.5 / 16.0 27.5 / 19.0 Heating High/Low ³/in 16.0 / 9.5 23.5 / 16.0 27.5 / 19.0 Sound Power Cooling High dba 51 54 58 Sound Pressure Cooling High/Low dba 33 / 28 37 / 32 41 / 35 Heating High/Low dba 34 / 28 37 / 32 41 / 35 1~/220-240V/50/60Hz Decoration Panel Model Colour BYCQ140CW1 Pure White (RAL 9010) HxWxD 50x950x950 5.5 Outdoor Unit RQ71B8V3B RQ71B8W1B RQ100B8V3B RQ100B8W1B RQ125B8W1B Heating Min~Max CWB Sound Pressure (Standard) Cooling dba Piping connections Liquid (OD)/Gas/Drain Piping Length (Maxiu) Max. internunit level difference 770x900x320 1170x900x320 84 83 103 101 108-5.0~46.0-10.0~15.0 63.0 66.0 67.0 50.0 53.0 1~/230V/50Hz 3N~/400V/50Hz 1~/230V/50Hz 3N~/400V/50Hz 9.52 / 15.9 / 26 70 0.5 69

FCQ-C / REQ-B * Round Flow Cassette BRC1D52 BRC7F532 FCQ100,125C REQ100,125B Modern style decoration panel in white (RAL9010) 360 air discharge ensures unifor air fl ow and teperature distribution Air discharge fro the corners avoids dead zones that ay be subject to teperature differences Cofortable horizontal air discharge ensures draughtfree operation and prevents ceiling soiling 23 different air fl ow patterns possible Fresh air intake: up to 20 % Reduced installation height: 214 for class 71 Easy visible drain check thanks to clear drain socket heat pup 2 steps standard HEAT PUMP NON-INVERTER Indoor Units FCQ71C7VEB FCQ100C7VEB FCQ125C7VEB Noinal Capacity Cooling capacity Standard kw 7.1 7.1 10.0 10.0 12.5 Heating capacity Standard kw 8.0 8.0 11.2 11.2 14.6 EER / COP Cooling / Heating 2.61 / 2.81 2.67 / 2.86 2.61 / 2.99 2.81 / 3.06 2.68 / 2.89 Annual energy consuption 1360 1330 1915 1780 2330 cooling / heating D / D D / D C / D D / D 204x840x840 246x840x840 246x840x840 21 23 23 Air Flow Rate Cooling High/Low ³/in 15.5 / 9.0 23.5 / 16.0 27.5 / 19.0 Heating High/Low ³/in 16.0 / 9.5 23.5 / 16.0 27.5 / 19.0 Sound Power Cooling High dba 51 54 58 Sound Pressure Cooling High/Low dba 33 / 28 37 / 32 41 / 35 Heating High/Low dba 34 / 28 37 / 32 41 / 35 1~/220-240V/50/60Hz 1~/220-240V/50/60Hz 1~/220-240V/50/60Hz Decoration Panel Model BYCQ140CW1 BYCQ140CW1 BYCQ140CW1 Colour Pure White (RAL 9010) Pure White (RAL 9010) Pure White (RAL 9010) HxWxD 50x950x950 50x950x950 50x950x950 Outdoor Unit REQ71B8V3B REQ71B8W1B REQ100B8V3B REQ100B8W1B REQ125B8W1B 770x900x320 1170x900x320 83 102 100 108 Sound pressure level Cooling dba 53 53 57 57 57 Sound power level Cooling dba 65 65 70 70 70 10.0~46.0 Heating Min~Max CWB -10~15 1~/230V/50Hz 3N~/400V/50Hz 1~/230V/50Hz 3N~/400V/50Hz Piping connections Liquid (OD)/Gas/Drain 9.52 / 15.9 / 26 Piping Length (Maxiu) 50 Max. internunit level difference 0.5 * Cobination only available in Portugal, Greece, Cyprus and Malta 70

FCQ-C / RZQS-C Round Flow Cassette Modern style decoration panel in white (RAL9010) 360 air discharge ensures unifor air fl ow and teperature distribution Air discharge fro the corners avoids dead zones that ay be subject to teperature differences Cofortable horizontal air discharge ensures draughtfree operation and prevents ceiling soiling 23 different air fl ow patterns possible Reduced installation height: 214 for class 71 Fresh air intake: up to 20 % Easy visible drain check thanks to clear drain socket BRC1D52 BRC7E63 FCQ100,125,140C RZQS125,140C heat pup 2 steps standard HEAT PUMP INVERTER Indoor Units FCQ71C7VEB FCQ100C7VEB FCQ125C7VEB FCQ140C7VEB Capacity Cooling capacity Standard kw 7.1 10.0 12.5 14.0 Heating capacity Standard kw 8.0 11.2 14.0 16.0 EER / COP Cooling / Heating 2.89 / 3.07 2.61 / 3.23 3.02 / 3.1 2.61 / 2.81 Annual energy consuption 1,230 1,915 2,070 2,680 cooling / heating C / D D / C B / D D / D 204x840x840 246x840x840 21 23 Air Flow Rate Cooling High/Low ³/in 15.5 / 9.0 23.5 / 16.0 27.5 / 19.0 Heating High/Low ³/in 16.0 / 9.5 23.5 / 16.0 27.5 / 19.0 Sound Power Cooling High dba 51 54 58 Sound Pressure Cooling High/Low dba 33 / 28 37 / 32 41 / 35 Heating High/Low dba 34 / 28 37 / 32 41 / 35 42 / 35 1~/220-240V/50/60Hz Decoration Panel Model Colour BYCQ140CW1 Pure White (RAL 9010) HxWxD 50x950x950 5.5 Outdoor Unit RZQS71C7V1B RZQS100C7V1B RZQS125C7V1B RZQS140C7V1B Heating Min~Max CWB Sound Pressure (Standard) Cooling dba Heating dba Sound Level (Night quiet) Sound Pressure dba Piping connections Liquid (OD)/Gas/Drain Piping Length (Maxiu) Max. internunit level difference 770x900x320 700x900x320 1,170x900x320 1170x900x320 68 103-5~46-15~15.5 65 67 68 49 51 52 51 55 53 54 47 49 50 9.52 / 15.9 / 26 30 50 0.5 71

FCQ-C / RZQ-C Round Flow Cassette Modern style decoration panel in white (RAL9010) 360 air discharge ensures unifor air fl ow and teperature distribution Air discharge fro the corners avoids dead zones that ay be subject to teperature differences Cofortable horizontal air discharge ensures draughtfree operation and prevents ceiling soiling 23 different air fl ow patterns possible Reduced installation height: 214 for class 71 Fresh air intake: up to 20 % Easy visible drain check thanks to clear drain socket BRC1D52 BRC7E63 FCQ71C RZQ100,125,140C heat pup 2 steps standard HEAT PUMP INVERTER Indoor Units FCQ71C7VEB FCQ100C7VEB FCQ125C7VEB FCQ140C7VEB Capacity Cooling capacity Standard kw 7.1 10.0 12.5 14.0 Heating capacity Standard kw 8.0 11.2 14.0 16.0 EER / COP Cooling / Heating 3.36 / 3.62 3.61 / 3.71 3.22 / 3.54 2.61 / 3.21 Annual energy consuption 1,055 1385 1940 2680 cooling / heating A / A A / B D / C 204x840x840 246x840x840 21 23 Air Flow Rate Cooling High/Low ³/in 15.5 / 9.0 23.5 / 16.0 27.5 / 19.0 Heating High/Low ³/in 16.0 / 9.5 23.5 / 16.0 27.5 / 19.0 Sound Power Cooling High dba 51 54 58 Sound Pressure Cooling High/Low dba 33 / 28 37 / 32 41 / 35 Heating High/Low dba 34 / 28 37 / 32 41 / 35 42 / 35 1~/220-240V/50/60Hz Decoration Panel Model Colour BYCQ140CW1 Pure White (RAL 9010) HxWxD 50x950x950 5.5 Outdoor Unit RZQ71C7V1B RZQ100C7V1B RZQ125C7V1B RZQ140C7V1B Heating Min~Max CWB Sound Pressure (Standard) Cooling dba Heating dba Sound Level (Night quiet) Sound Pressure dba Piping connections Liquid (OD)/Gas/Drain Piping Length (Maxiu) Max. internunit level difference 770x900x320 1170x900x320 67 103-15.0~50.0-20.0~15.5 63 65 66 67 47 49 50 49 51 52 43 45 46 9.52 / 15.9 / 26 50 75 0.5 72

FCQ-C / RZQ-BW1 Round Flow Cassette Modern style decoration panel in white (RAL9010) 360 air discharge ensures unifor air fl ow and teperature distribution Air discharge fro the corners avoids dead zones that ay be subject to teperature differences Cofortable horizontal air discharge ensures draughtfree operation and prevents ceiling soiling 23 different air fl ow patterns possible Fresh air intake: up to 20 % Easy visible drain check thanks to clear drain socket BRC1D52 BRC7E63 FCQ100,125,140C RZQ100,125,140B heat pup 2 steps standard HEAT PUMP INVERTER Indoor Units FCQ100C7VEB FCQ125C7VEB FCQ140C7VEB Capacity Cooling capacity Standard kw 10.0 12.50 14.00 Heating capacity Standard kw 11.20 14.00 16.00 EER / COP Cooling / Heating 3.79 / 3.57 3.22 / 3.21 2.61 / 2.81 Annual energy consuption 1320 1940 2680 cooling / heating A / B A / C D / D Air Flow Rate Cooling High/Low ³/in Heating High/Low ³/in Sound Power Cooling High dba Sound Pressure Cooling High/Low dba Heating High/Low dba Decoration Panel Model 246x840x840 23 23.5 / 16.0 27.5 / 19.0 23.5 / 16.0 27.5 / 19.0 54 58 37 / 32 41 / 35 37 / 32 41 / 35 42 / 35 1~/220-240V/50/60Hz BYCQ140CW1 Colour Pure White (RAL 9010) HxWxD 50x950x950 5.5 Outdoor Unit RZQ100B8W1B RZQ125B8W1B RZQ140B8W1B Heating Min~Max CWB Sound Pressure (Standard) Cooling dba Heating dba Sound Level (Night quiet) Sound Pressure dba Piping connections Liquid (OD)/Gas/Drain Piping Length (Maxiu) Max. internunit level difference 1345x900x320 106-15.0~50.0-20.0~15.5 65.0 66.0 49.0 50.0 51.0 52.0 45.0 3N~/400V/50Hz 9.52 / 15.9 / 26 75 0.5 73

74

FCQH-C / RZQS-C Round Flow Cassette Iproved operating effi ciency Modern style decoration panel in white (RAL9010) 360 air discharge ensures unifor air fl ow and teperature distribution Air discharge fro the corners avoids dead zones that ay be subject to teperature differences Cofortable horizontal air discharge ensures draughtfree operation and prevents ceiling soiling 23 different air fl ow patterns possible Fresh air intake: up to 20 % Easy visible drain check thanks to clear drain socket BRC1D52 BRC7F532 FCQH100,125,140C RZQS125,140C heat pup 2 steps standard HEAT PUMP INVERTER Indoor Units FCQH71C7VEB FCQH100C7VEB FCQH125C7VEB FCQH140C7VEB Capacity Cooling capacity Standard kw 7.1 10.0 12.5 14.0 Heating capacity Standard kw 8.0 11.2 14.0 16.0 EER / COP Cooling / Heating 3.01 / 3.41 2.81 / 3.41 3.22 / 3.41 2.81 / 3.21 Annual energy consuption 1,180 1,780 1,940 2,490 cooling / heating B / B C / B A / B C / C 246x840x840 288x840x840 23 25 Air Flow Rate Cooling High/Low ³/in 20.0 / 12.0 32.5 / 18.0 32.5 / 21.5 Heating High/Low ³/in 20.0 / 12.0 32.5 / 18.0 32.5 / 21.5 Sound Power Cooling High dba 52 60 Sound Pressure Cooling High/Low dba 34 / 28 43 / 32 43 / 36 43 / 38 Heating High/Low dba 34 / 28 43 / 32 43 / 36 43 / 38 1~/220-240V/50/60Hz Decoration Panel Model Colour BYCQ140CW1 Pure White (RAL 9010) HxWxD 50x950x950 5.5 Outdoor Unit RZQS71C7V1B RZQS100C7V1B RZQS125C7V1B RZQS140C7V1B Heating Min~Max CWB Sound Pressure (Standard) Cooling dba Heating dba Sound Level (Night quiet) Sound Pressure dba Piping connections Liquid (OD)/Gas/Drain Piping Length (Maxiu) Max. internunit level difference 770x900x320 700x900x320 1,170x900x320 1170x900x320 68 103-5~46-15~15.5 65 67 68 49 51 52 51 55 53 54 47 49 50 9.52 / 15.9 / 26 30 50 0.5 75

FCQH-C / RZQ-C Round Flow Cassette Iproved operating effi ciency Modern style decoration panel in white (RAL9010) 360 air discharge ensures unifor air fl ow and teperature distribution Air discharge fro the corners avoids dead zones that ay be subject to teperature differences Cofortable horizontal air discharge ensures draughtfree operation and prevents ceiling soiling 23 different air fl ow patterns possible Fresh air intake: up to 20 % Easy visible drain check thanks to clear drain socket BRC1D52 BRC7F532 FCQH100,125,140C RZQ100,125,140C 2 steps heat pup standard HEAT PUMP INVERTER Indoor Units FCQH71C7VEB FCQH100C7VEB FCQH125C7VEB FCQH140C7VEB Capacity Cooling capacity Standard kw 7.1 10.0 12.5 14.0 Heating capacity Standard kw 8.0 11.2 14.0 16.0 EER / COP Cooling / Heating 3.59 / 4.06 3.76 / 4.39 3.38 / 3.92 3.02 / 3.61 Annual energy consuption 990 1330 1850 2320 cooling / heating A / A B / A 246x840x840 288x840x840 23 25 Air Flow Rate Cooling High/Low ³/in 20.0 / 12.0 32.5 / 18.0 32.5 / 21.5 Heating High/Low ³/in 20.0 / 12.0 32.5 / 18.0 32.5 / 21.5 Sound Power Cooling High dba 52 60 Sound Pressure Cooling High/Low dba 34 / 28 43 / 32 43 / 36 43 / 38 Heating High/Low dba 34 / 28 43 / 32 43 / 36 43 / 38 1~/220-240V/50/60Hz Decoration Panel Model Colour BYCQ140CW1 Pure White (RAL 9010) HxWxD 50x950x950 5.5 Outdoor Unit RZQ71C7V1B RZQ100C7V1B RZQ125C7V1B RZQ140C7V1B Heating Min~Max CWB Sound Pressure (Standard) Cooling dba Heating dba Sound Level (Night quiet) Sound Pressure dba Piping connections Liquid (OD)/Gas/Drain Piping Length (Maxiu) Max. internunit level difference 770x900x320 1170x900x320 67 103-15.0~50.0-20.0~15.5 63 65 66 67 47 49 50 49 51 52 43 45 46 9.52 / 15.9 / 26 50 75 0.5 76

FCQH-C / RZQ-BW1 Round Flow Cassette Iproved operating effi ciency Modern style decoration panel in white (RAL9010) 360 air discharge ensures unifor air fl ow and teperature distribution Air discharge fro the corners avoids dead zones that ay be subject to teperature differences Cofortable horizontal air discharge ensures draughtfree operation and prevents ceiling soiling 23 different air fl ow patterns possible Fresh air intake: up to 20 % Easy visible drain check thanks to clear drain socket BRC1D52 BRC7F532 FCQH100,125,140C RZQ100,125,140B heat pup 2 steps standard HEAT PUMP INVERTER Indoor Units FCQH100C7VEB FCQH125C7VEB FCQH140C7VEB Capacity Cooling capacity Standard kw 10.00 12.50 14.00 Heating capacity Standard kw 11.20 14.00 16.00 EER / COP Cooling / Heating 4.10 / 4.38 3.53 / 3.90 3.01 / 3.54 Annual energy consuption 1220 1770 2325 cooling / heating A / A B / B Air Flow Rate Cooling High/Low ³/in Heating High/Low ³/in Sound Power Cooling High dba Sound Pressure Cooling High/Low dba Heating High/Low dba Decoration Panel Model 288x840x840 25 32.5 / 18.0 32.5 / 21.5 32.5 / 18.0 32.5 / 21.5 60 43 / 32 43 / 36 43 / 38 43 / 32 43 / 36 43 / 38 1~/220-240V/50/60Hz BYCQ140CW1 Colour Pure White (RAL 9010) HxWxD 50x950x950 5.5 Outdoor Unit RZQ100B8W1B RZQ125B8W1B RZQ140B8W1B Heating Min~Max CWB Sound Pressure (Standard) Cooling dba Heating dba Sound Level (Night quiet) Sound Pressure dba Piping connections Liquid (OD)/Gas/Drain Piping Length (Maxiu) Max. internunit level difference 1345x900x320 106-15.0~50.0-20.0~15.5 65.0 66.0 49.0 50.0 51.0 52.0 45.0 3N~/400V/50Hz 9.52 / 15.9 / 26 75 0.5 77

FFQ-B / RXS-G 4-Way Blow Ceiling Mounted Cassette (600 x 600) New and extreely copact casing (575 in width and depth) enables unit to fi t fl ush into ceilings and atch standard architectural odules, without cutting ceiling tiles Modern style decoration panel in white (RAL9010) Sli design for fl exible installation Ideal for shops, restaurants or offi ces requiring axiu fl oor space for furniture, decorations and fi ttings Extreely quiet in operation Possibility to shut 1 or 2 fl aps for easy installation in corners Auto-swing function ensures effi cient air and teperature distribution and prevents ceiling soiling. Excellent low draught characteristics Easy installation and aintenance BRC1D52 BRC7E531 The switch box can be reached by siply reoving the suction grille; therefore aintenance can be done very easily. FFQ-B RXS25,35G heat pup standard 2 steps HEAT PUMP INVERTER Indoor Units FFQ25B8V1B FFQ35B8V1B FFQ50B8V1B Capacity Cooling capacity Miniu kw Standard kw Maxiu kw Heating capacity Miniu kw Standard kw Maxiu kw EER / COP Cooling / Heating Annual energy consuption cooling / heating Air Flow Rate Cooling High/Low ³/in Heating High/Low ³/in Sound Power Cooling High dba Sound Pressure Cooling High/Low dba Heating High/Low dba Decoration Panel Model - - - 2.5 3.4 4.7 - - - - - - 3.2 4.0 5.5 - - - 3.42/3.48 3.09/3.33 2.61/2.81 365 550 900 A/B B/C D 286x575x575 286x575x575 286x575x575 17.5 17.5 17.5 9.0 / 6.5 10.0 / 6.5 12.0 / 8.0 9.0 / 6.5 10.0 / 6.5 12.0 / 8.0 46.5 49.0 53.0 29.5 / 24.5 32.0 / 25.0 36.0 / 27.0 29.5 / 24.5 32.0 / 25.0 36.0 / 27.0 1~/230V/50Hz 1~/230V/50Hz 1~/230V/50Hz BYFQ60BAW1 BYFQ60BAW1 BYFQ60BAW1 Colour Pure White (RAL 9010) Pure White (RAL 9010) Pure White (RAL 9010) HxWxD 55x700x700 55x700x700 55x700x700 2.7 2.7 2.7 Outdoor Unit RXS25G2V1B RXS35G2V1B RXS50G2V1B Heating Min~Max CWB Sound Pressure (Low) Cooling dba Heating dba Sound Pressure (High) Cooling dba Heating dba Piping connections Liquid (OD)/Gas/Drain Piping Length (Maxiu) 550x765x285 550x765x285 735x825x300 34 34 48-10~46-10~46-10~46-15~20-15~20-15~20 61 63 61 43 44 44 44 45 45 46 48 48 47 48 48 6.35 / 9.52/18 6.35 / 9.52/18 6.35 / 12.7/18 20 20 30 78

FFQ-B / RXS-F 4-way Blow Ceiling Mounted Cassette (600 x 600) New and extreely copact casing (575 in width and depth) enables unit to fi t fl ush into ceilings and atch standard architectural odules, without cutting ceiling tiles Modern style decoration panel in white (RAL9010) Sli design for fl exible installation Ideal for shops, restaurants or offi ces requiring axiu fl oor space for furniture, decorations and fi ttings Extreely quiet in operation Possibility to shut 1 or 2 fl aps for easy installation in corners Auto-swing function ensures effi cient air and teperature distribution and prevents ceiling soiling. Excellent low draught characteristics Easy installation and aintenance The switch box can be reached by siply reoving the suction grille; therefore aintenance can be done very easily. BRC1D52 BRC7E531 FFQ60B RXS60F standard heat pup 2 steps HEAT PUMP INVERTER Indoor Units FFQ60B8V1B Capacity Cooling capacity Standard kw 5.8 Heating capacity Standard kw 7.0 EER / COP Cooling / Heating 2.80 / 2.81 Annual energy consuption 1035 Cooling / heating D / D 286x575x575 17.5 Air Flow Rate Cooling High/Low ³/in 15.0 / 10.0 Heating High/Low ³/in 15.0 / 10.0 Sound Power Cooling High dba 58.0 Sound Pressure Cooling High/Low dba 41.0 / 32.0 Heating High/Low dba 41.0 / 32.0 Decoration Panel Model Colour 1~/230V/50Hz BYFQ60BAW1 Pure White (RAL 9010) HxWxD 55x700x700 2.7 Outdoor Unit Heating Min~Max CWB Sound Pressure (Standard) Cooling dba Heating dba Sound Level (Night quiet) Sound Pressure dba Piping connections Liquid (OD)/Gas/Drain Piping Length (Maxiu) RXS60F2V1B 735x825x300 48-10~46-15~18 63 49 49 46 1~/220-240/220-230V/50Hz 6.35 / 12.7 / 18 30 79

FCQ-C / RKS-G Round Flow Cassette Modern style decoration panel in white (RAL9010) 360 air discharge ensures unifor air fl ow and teperature distribution Air discharge fro the corners avoids dead zones that ay be subject to teperature differences Cofortable horizontal air discharge ensures draughtfree operation and prevents ceiling soiling 23 different air fl ow patterns possible Reduced installation height: 214 for class 35-50 Fresh air intake: up to 20 % Easy visible drain check thanks to clear drain socket BRC1D52 BRC7E63 FCQ35,50C RKS35G 2 steps COOLING ONLY INVERTER Indoor Units FCQ35C7VEB FCQ50C7VEB Capacity Cooling capacity Miniu kw Standard kw Maxiu kw EER Noinal Annual energy consuption cooling Air Flow Rate Cooling High/Low ³/in Sound Power Cooling High dba Sound Pressure Cooling High/Low dba Decoration Panel Model Colour HxWxD 1.4 0.9 3.4 5.0 3.7 5.6 3.58 3.55 475 705 A A 204x840x840 204x840x840 19 19 10.5 / 8.5 12.5 / 8.5 49 49 31 / 27 31 / 27 /60Hz /60Hz BYCQ140CW1 BYCQ140CW1 50x950x950 50x950x950 5.5 5.5 Outdoor Unit RKS35G2V1B RKS50G2V1B Sound Pressure (Low) Cooling dba Sound Pressure (High) Cooling dba Piping connections Liquid (OD)/Gas/Drain Piping Length (Maxiu) 550x765x285 735x825x300 34 48-10~46-10~46 62 61 44 44 48 48 6.35 / 9.52 / 18 6.35 / 12.7 / 18 20 30 80

FCQ-C / RKS-F Round Flow Cassette Modern style decoration panel in white (RAL9010) 360 air discharge ensures unifor air fl ow and teperature distribution Air discharge fro the corners avoids dead zones that ay be subject to teperature differences Cofortable horizontal air discharge ensures draughtfree operation and prevents ceiling soiling 23 different air fl ow patterns possible Reduced installation height: 214 for class 66 Fresh air intake: up to 20 % Easy visible drain check thanks to clear drain socket BRC1D52 BRC7F533 FCQ60C 2 steps RKS60F COOLING ONLY INVERTER Indoor Units FCQ60C7VEB Capacity Cooling capacity Miniu kw 0.9 Standard kw 5.7 Maxiu kw 6.0 EER Noinal 3.48 Annual energy consuption 820 cooling A 204x840x840 19 Air Flow Rate Cooling High/Low ³/in 13.5 / 8.5 Sound Power Cooling High dba 51 Sound Pressure Cooling High/Low dba 33 / 28 Decoration Panel Model Colour - BYCQ140CW1 Pure White (RAL 9010) HxWxD 50x950x950 5.5 Outdoor Unit Sound Pressure (Standard) Cooling dba Piping connections Liquid (OD)/Gas/Drain Piping Length (Maxiu) RKS60F2V1B 735x825x300 47-10~46 63 49(H) - 46(SL) 6.35 / 12.7 / 18 30 81

FCQ-C / RN-E Round Flow Cassette Modern style decoration panel in white (RAL9010) 360 air discharge ensures unifor air fl ow and teperature distribution Air discharge fro the corners avoids dead zones that ay be subject to teperature differences Cofortable horizontal air discharge ensures draughtfree operation and prevents ceiling soiling 23 different air fl ow patterns possible Fresh air intake: up to 20 % Reduced installation height: 214 for class 50-60 Easy visible drain check thanks to clear drain socket BRC1D52 BRC7F533 FCQ50,60C 2 steps RN50,60E COOLING ONLY NON-INVERTER Indoor Units FCQ50C7VEB FCQ60C7VEB Noinal Capacity Cooling capacity Standard kw 5.0 5.7 EER Noinal 3.55 3.48 Annual energy consuption 705 820 cooling A A 204x840x840 204x840x840 19 19 Air Flow Rate Cooling High/Low ³/in 12.5 / 8.5 13.5 / 8.5 Sound Power Cooling High dba 49 51 Sound Pressure Cooling High/Low dba 31 / 27 33 / 28 1~/220-240V/50/60Hz 1~/220-240V/50/60Hz Decoration Panel Model BYCQ140CW1 BYCQ140CW1 Colour Pure White (RAL 9010) Pure White (RAL 9010) HxWxD 50x950x950 50x950x950 Outdoor Unit RN50E3V1B RN60E3V1B 735x825x300 735x825x300 47 47 Sound pressure level Cooling H dba 47 49 Sound power level Cooling H dba 61 63-10.0~46.0-10.0~46.0 Piping connections Liquid (OD)/Gas/Drain 6.35 / 12.7 / 18 6.35 / 12.7 / 18 Piping Length (Maxiu) 30 30 Max. internunit level difference 20 20 82

FCQ-C / RR-B Round Flow Cassette Modern style decoration panel in white (RAL9010) 360 air discharge ensures unifor air fl ow and teperature distribution Air discharge fro the corners avoids dead zones that ay be subject to teperature differences Cofortable horizontal air discharge ensures draughtfree operation and prevents ceiling soiling 23 different air fl ow patterns possible Reduced installation height: 214 for class 71 Fresh air intake: up to 20 % Easy visible drain check thanks to clear drain socket BRC1D52 BRC7F533 FCQ100,125C 2 steps RR100B COOLING ONLY NON-INVERTER Indoor Units FCQ71C7VEB FCQ100C7VEB FCQ125C7VEB Capacity Cooling capacity Standard kw 7.10 7.10 10.00 10.00 12.50 EER Noinal 2.61 2.67 2.61 2.81 2.68 Annual energy consuption 1360 1330 1915 1780 2330 cooling D D D C D 204x840x840 246x840x840 21 23 Air Flow Rate Cooling High/Low ³/in 15.5 / 9.0 23.5 / 16.0 27.5 / 19.0 Sound Power Cooling High dba 51 54 58 Sound Pressure Cooling High/Low dba 33 / 28 37 / 32 41 / 35 - Decoration Panel Model Colour BYCQ140CW1 Pure White (RAL 9010) HxWxD 50x950x950 5.5 Outdoor Unit RR71B8V3B RR71B8W1B RR100B8V3B RR100B8W1B RR125B8W1B Sound Pressure (Standard) Cooling dba Piping connections Liquid (OD)/Gas/Drain Piping Length (Maxiu) Max. internunit level difference 770x900x320 1170x900x320 83 81 102 99 106-15.0~46.0 63.0 66.0 67.0 50.0 53.0 1~/230V/50Hz 3N~/400V/50Hz 1~/230V/50Hz 3N~/400V/50Hz 9.52 / 15.9 / 26 70 0.5 83

FFQ-B / RKS-G 4-Way Blow Ceiling Mounted Cassette (600 x 600) New and extreely copact casing (575 in width and depth) enables unit to fi t fl ush into ceilings and atch standard architectural odules, without cutting ceiling tiles Modern style decoration panel in white (RAL9010) Sli design for fl exible installation Ideal for shops, restaurants or offi ces requiring axiu fl oor space for furniture, decorations and fi ttings Extreely quiet in operation Possibility to shut 1 or 2 fl aps for easy installation in corners Auto-swing function ensures effi cient air and teperature distribution and prevents ceiling soiling. Excellent low draught characteristics Easy installation and aintenance The switch box can be reached by siply reoving the suction grille; therefore aintenance can be done very easily. BRC1D52 BRC7E531 FFQ-B RKS25,35G standard 2 steps COOLING ONLY INVERTER Indoor Units FFQ25B8V1B FFQ35B8V1B FFQ50B8V1B Capacity Cooling capacity Miniu kw Standard kw Maxiu kw EER Noinal Annual energy consuption cooling Air Flow Rate Cooling High/Low ³/in Sound Power Cooling High dba Sound Pressure Cooling High/Low dba Decoration Panel Model - - - 2.5 3.4 4.7 - - - 3.42 3.09 2.61 365 550 900 A B D 286x575x575 286x575x575 286x575x575 17.5 17.5 17.5 9.0 / 6.5 10.0 / 6.5 12.0 / 8.0 46.5 49.0 53.0 29.5 / 24.5 32.0 / 25.0 36.0 / 27.0 1~/230V/50Hz 1~/230V/50Hz 1~/230V/50Hz BYFQ60BAW1 BYFQ60BAW1 BYFQ60BAW1 Colour Pure White (RAL 9010) Pure White (RAL 9010) Pure White (RAL 9010) HxWxD 55x700x700 55x700x700 55x700x700 2.7 2.7 2.7 Outdoor Unit RKS25G2V1B RKS35G2V1B RKS50G2V1B 550x765x285 550x765x285 735x825x300 34 34 48-10~46-10~46-10~46 61 62 61 Sound Pressure (Low) Cooling dba 43 44 44 Sound Pressure (High) Cooling dba 46 48 48 Piping connections Liquid (OD)/Gas/Drain 6.35 / 9.52 / 18 6.35 / 9.52 / 18 6.35 / 12.7 / 18 Piping Length (Maxiu) 20 20 30 84

FFQ-B / RKS-F 4-way Blow Ceiling Mounted Cassette (600 x 600) New and extreely copact casing (575 in width and depth) enables unit to fi t fl ush into ceilings and atch standard architectural odules, without cutting ceiling tiles Modern style decoration panel in white (RAL9010) Sli design for fl exible installation Ideal for shops, restaurants or offi ces requiring axiu fl oor space for furniture, decorations and fi ttings Extreely quiet in operation Possibility to shut 1 or 2 fl aps for easy installation in corners Auto-swing function ensures effi cient air and teperature distribution and prevents ceiling soiling. Excellent low draught characteristics Easy installation and aintenance The switch box can be reached by siply reoving the suction grille; therefore aintenance can be done very easily. BRC1D52 BRC7E531 FFQ60B RKS60F standard 2 steps COOLING ONLY Indoor Units Capacity Cooling capacity Miniu kw Standard kw Maxiu kw EER Noinal Annual energy consuption cooling Air Flow Rate Cooling High/Low ³/in Sound Power Cooling High dba Sound Pressure Cooling High/Low dba Decoration Panel Model INVERTER FFQ60B8V1B - 5.8-2.80 1035 D 286x575x575 17.5 15.0 / 10.0 58.0 41.0 / 32.0 1~/230V/50Hz BYFQ60BAW1 Colour Pure White (RAL 9010) HxWxD 55x700x700 2.7 Outdoor Unit Sound Pressure (Standard) Cooling dba Piping connections Liquid (OD)/Gas/Drain Piping Length (Maxiu) RKS60F2V1B 735x825x300 47-10~46 63 49(H) - 46(SL) 6.35 / 12.7 / 18 30 85

FFQ-B / RN-E 4-way Blow Ceiling Mounted Cassette (600 x 600) New and extreely copact casing (575 in width and depth) enables unit to fi t fl ush into ceilings and atch standard architectural odules, without cutting ceiling tiles Modern style decoration panel in white (RAL9010) Sli design for fl exible installation Ideal for shops, restaurants or offi ces requiring axiu fl oor space for furniture, decorations and fi ttings Extreely quiet in operation Possibility to shut 1 or 2 fl aps for easy installation in corners Auto-swing function ensures effi cient air and teperature distribution and prevents ceiling soiling. Excellent low draught characteristics Easy installation and aintenance The switch box can be reached by siply reoving the suction grille; therefore aintenance can be done very easily. BRC1D52 BRC7E531 FFQ50,60B RN50,60E standard 2 steps COOLING ONLY NON-INVERTER Indoor Units FFQ50B8V1B FFQ60B8V1B Noinal Capacity Cooling capacity Standard kw 4.7 5.8 Miniu kw - - Maxiu kw - - EER Noinal 2.61 2.80 Annual energy consuption 900 1035 cooling D D 286x575x575 286x575x575 17.5 17.5 Air Flow Rate Cooling High/Low ³/in 12.0 / 8.0 15.0 / 10.0 Sound Power Cooling High dba 53.0 58.0 Sound Pressure Cooling High/Low dba 36.0 / 27.0 41.0 / 32.0 Decoration Panel Model Colour 1~/230V/50Hz BYFQ60BAW1 Pure White (RAL 9010) 1~/230V/50Hz BYFQ60BAW1 Pure White (RAL 9010) HxWxD 55x700x700 55x700x700 2.7 2.7 Outdoor Unit RN50E3V1B RN60E3V1B Sound Power Cooling H dba Sound Pressure Cooling H dba Piping connections Liquid (OD)/Gas/Drain Piping Length (Maxiu) Max. internunit level difference 735x825x300 735x825x300 47 47-10.0~46.0-10.0~46.0 61.0 63.0 47.0 49.0 6.35 / 12.7 / 18 6.35 / 12.7 / 18 30 30 20 20 86

FUQ-B / RQ-B 4-Way Blow Ceiling Suspended Cassette Can be installed in both new and existing buildings. Ideal for shops, restaurants or offi ces requiring axiu fl oor space for furniture, decorations and fi ttings Air can be discharged in any of 4 directions Air fl ow distribution for ceiling heights up to 3.5 without loss of capacity. No ceiling staining Possibility to shut 1 or 2 fl aps for easy installation in corners Air fi lter, drain pan and heat exchanger fi n are ildew proof and anti-bacterial treated. Drain-up pup with 500 lift fi tted as standard Easy to install BRC1D52 BRC7C529 FUQ71B standard heat pup RQ100B 2 steps HEAT PUMP NON-INVERTER Indoor Units FUQ71BVV1B FUQ100BVV1B FUQ125BVV1B Capacity Cooling capacity Standard kw 7.1 7.1 10.0 10.0 12.2 Heating capacity Standard kw 8.0 8.0 11.2 11.2 14.5 EER / COP Cooling / Heating 2.63 / 3.16 2.68 / 3.28 2.61 / 3.13 2.65 / 3.16 2.67 / 2.97 Annual energy consuption 1350 1325 1915 1890 2285 cooling / heating D / D D / C D / D D / D D / D Air Flow Rate Cooling High/Low ³/in Heating High/Low ³/in Sound Power Cooling High/Low dba Heating High/Low dba Sound Pressure Cooling High/Low dba Heating High/Low dba 165x895x895 230x895x895 25.0 31.0 19.0 / 14.0 29.0 / 21.0 32.0 / 23.0 19.0 / 14.0 29.0 / 21.0 32.0 / 23.0 56.0 / 51.0 59.0 / 54.0 60.0 / 55.0 56.0 / 51.0 59.0 / 54.0 60.0 / 55.0 40.0 / 35.0 43.0 / 38.0 44.0 / 39.0 40.0 / 35.0 43.0 / 38.0 44.0 / 39.0 Outdoor Unit RQ71B8V3B RQ71B8W1B RQ100B8V3B RQ100B8W1B RQ125B8W1B Heating Min~Max CWB Sound Pressure (Standard) Cooling dba Piping connections Liquid (OD)/Gas/Drain Piping Length (Maxiu) Max. internunit level difference 770x900x320 1170x900x320 84 83 103 101 108-5.0~46.0-10.0~15.0 63.0 66.0 67.0 50.0 53.0 1~/230V/50Hz 3N~/400V/50Hz 1~/230V/50Hz 3N~/400V/50Hz 9.52 / 15.9 / 26 70 0.5 87

FUQ-B / RZQ-C 4-Way Blow Ceiling Suspended Cassette Can be installed in both new and existing buildings. Ideal for shops, restaurants or offi ces requiring axiu fl oor space for furniture, decorations and fi ttings Air can be discharged in any of 4 directions Air fl ow distribution for ceiling heights up to 3.5 without loss of capacity. No ceiling staining Possibility to shut 1 or 2 fl aps for easy installation in corners Air fi lter, drain pan and heat exchanger fi n are ildew proof and anti-bacterial treated. Drain-up pup with 500 lift fi tted as standard Easy to install BRC1D52 BRC7C529 FUQ-B RZQ100,125C standard heat pup 2 steps HEAT PUMP INVERTER Indoor Units FUQ71BVV1B FUQ100BVV1B FUQ125BVV1B Capacity Cooling capacity Standard kw 7.1 10 12.5 Heating capacity Standard kw 8.0 11.2 14.0 EER / COP Cooling / Heating 3.21 / 3.42 3.21 / 3.32 3.01 / 3.23 Annual energy consuption 1,105 1560 2075 cooling / heating A / B A / C B / C 165x895x895 230x895x895 25.0 31.0 Air Flow Rate Cooling High/Low ³/in 19.0 / 14.0 29.0 / 21.0 32.0 / 23.0 Heating High/Low ³/in 19.0 / 14.0 29.0 / 21.0 32.0 / 23.0 Sound Power Cooling High/Low dba 56.0 / 51.0 59.0 / 54.0 60.0 / 55.0 Heating High/Low dba 56.0 / 51.0 59.0 / 54.0 60.0 / 55.0 Sound Pressure Cooling High/Low dba 40.0 / 35.0 43.0 / 38.0 44.0 / 39.0 Heating High/Low dba 40.0 / 35.0 43.0 / 38.0 44.0 / 39.0 Outdoor Unit RZQ71C7V1B RZQ100C7V1B RZQ125C7V1B 770x900x320 1170x900x320 67 103-15.0~50.0 Heating Min~Max CWB -20.0~15.5 63 65 66 Sound Pressure (Standard) Cooling dba 47 49 50 Heating dba 49 51 52 Sound Level (Night quiet) Sound Pressure dba 43 45 Piping connections Liquid (OD)/Gas/Drain 9.52 / 15.9 / 26 Piping Length (Maxiu) 50 75 Max. internunit level difference 0.5 88

FUQ-B / RZQ-BW1 4-Way Blow Ceiling Suspended Cassette Can be installed in both new and existing buildings. Ideal for shops, restaurants or offi ces requiring axiu fl oor space for furniture, decorations and fi ttings Air can be discharged in any of 4 directions Air fl ow distribution for ceiling heights up to 3.5 without loss of capacity. No ceiling staining Possibility to shut 1 or 2 fl aps for easy installation in corners Air fi lter, drain pan and heat exchanger fi n are ildew proof and anti-bacterial treated. Drain-up pup with 500 lift fi tted as standard Easy to install BRC1D52 BRC7C529 FUQ-B standard RZQ100,125B heat pup 2 steps HEAT PUMP INVERTER Indoor Units FUQ100BVV1B FUQ125BVV1B Capacity Cooling capacity Standard kw 10.00 12.50 Heating capacity Standard kw 11.20 14.00 EER / COP Cooling / Heating 3.21 / 3.41 3.09 / 3.21 Annual energy consuption 1560 2025 cooling / heating A / B B / C Air Flow Rate Cooling High/Low ³/in Heating High/Low ³/in Sound Power Cooling High/Low dba Heating High/Low dba Sound Pressure Cooling High/Low dba Heating High/Low dba 230x895x895 31.0 29.0 / 21.0 32.0 / 23.0 29.0 / 21.0 32.0 / 23.0 59.0 / 54.0 60.0 / 55.0 59.0 / 54.0 60.0 / 55.0 43.0 / 38.0 44.0 / 39.0 43.0 / 38.0 44.0 / 39.0 Outdoor Unit RZQ100B8W1B RZQ125B8W1B Heating Min~Max CWB Sound Pressure (Standard) Cooling dba Heating dba Sound Level (Night quiet) Sound Pressure dba Piping connections Liquid (OD)/Gas/Drain Piping Length (Maxiu) Max. internunit level difference 1345x900x320 106-15.0~50.0-20.0~15.5 65.0 66.0 49.0 50.0 51.0 52.0 45.0 3N~/400V/50Hz 9.52 / 15.9 / 26 75 0.5 89

FUQ-B / RR-B 4-Way Blow Ceiling Suspended Cassette Can be installed in both new and existing buildings. Ideal for shops, restaurants or offi ces requiring axiu fl oor space for furniture, decorations and fi ttings Air can be discharged in any of 4 directions Air fl ow distribution for ceiling heights up to 3.5 without loss of capacity. No ceiling staining Possibility to shut 1 or 2 fl aps for easy installation in corners Air fi lter, drain pan and heat exchanger fi n are ildew proof and anti-bacterial treated. Drain-up pup with 500 lift fi tted as standard Easy to install BRC1D52 BRC7C529 FUQ71B standard heat pup RR71B 2 steps COOLING ONLY NON-INVERTER Indoor Units FUQ71BVV1B FUQ100BVV1B FUQ125BVV1B Capacity Cooling capacity Standard kw 7.10 7.10 10.00 10.00 12.20 EER Noinal 2.63 2.68 2.61 2.65 2.67 Annual energy consuption 1350 1325 1915 1890 2285 cooling D D D Air Flow Rate Cooling High/Low ³/in Sound Power Cooling High/Low dba Heating High/Low dba Sound Pressure Cooling High/Low dba 165x895x895 230x895x895 25.0 31.0 19.0 / 14.0 29.0 / 21.0 32.0 / 23.0 56.0 / 51.0 59.0 / 54.0 60.0 / 55.0 56.0 / 51.0 59.0 / 54.0 60.0 / 55.0 40.0 / 35.0 43.0 / 38.0 44.0 / 39.0 Outdoor Unit RR71B8V3B RR71B8W1B RR100B8V3B RR100B8W1B RR125B8W1B Sound Pressure (Standard) Cooling dba Piping connections Liquid (OD)/Gas/Drain Piping Length (Maxiu) Max. internunit level difference 770x900x320 1170x900x320 83 81 102 99 106-15.0~46.0 63.0 66.0 67.0 50.0 53.0 1~/230V/50Hz 3N~/400V/50Hz 1~/230V/50Hz 3N~/400V/50Hz 9.52 / 15.9 / 26 70 0.5 90

FHQ-B / RXS-G Ceiling Suspended Unit Ideal solution for shops, restaurants or offi ces without false ceilings Copact design Leaves axiu fl oor and wall space for furniture, decorations and fi ttings Easy installation and aintenance Auto-swing function ensures effi cient air and teperature distribution. Air fl ow distribution for ceiling heights up to 3.8 without loss of capacity. BRC1D52 BRC7E66 FHQ-B heat pup RXS35G 2 steps 35~50 HEAT PUMP INVERTER Indoor Units FHQ35BVV1B FHQ50BVV1B Capacity Cooling capacity Miniu kw Standard kw Maxiu kw Heating capacity Miniu kw Standard kw Maxiu kw EER / COP Cooling / Heating Annual energy consuption Cooling / heating Air Flow Rate Cooling High/Low ³/in Heating High/Low ³/in Sound Power Cooling High/Low dba Heating High/Low dba Sound Pressure Cooling High/Low dba Heating High/Low dba 1.4 1.7 3.4 5.0 3.7 5.6 1.2 1.7 4.0 6.0 5.0 7.0 3.24 / 3.60 2.73 / 2.93 525 915 A / A D / C 195x960x680 195x960x680 24.0 25.0 13.0 / 10.0 13.0 / 10.0 13.0 / 10.0 13.0 / 10.0 53.0 / 48.0 54.0 / 49.0 53.0 / 48.0 54.0 / 49.0 37.0 / 32.0 38.0 / 33.0 37.0 / 32.0 38.0 / 33.0 Outdoor Unit RXS35G2V1B RXS50G2V1B Heating Min~Max CWB Sound Pressure (Low) Cooling dba Heating dba Sound Pressure (High) Cooling dba Heating dba Piping connections Liquid (OD)/Gas/Drain Piping Length (Maxiu) 550x765x285 735x825x300 34 48-10~46-10~46-15~20-15~20 63 61 44 44 45 45 48 48 48 48 6.35 / 9.52 / 18 6.35 / 12.7 / 18 20 30 91

FHQ-B / RXS-F Ceiling Suspended Unit Ideal solution for shops, restaurants or offi ces without false ceilings Copact design Leaves axiu fl oor and wall space for furniture, decorations and fi ttings Easy installation and aintenance Auto-swing function ensures effi cient air and teperature distribution. Air fl ow distribution for ceiling heights up to 3.8 without loss of capacity. BRC1D52 BRC7E63 FHQ60B RXS60F heat pup 2 steps 60 HEAT PUMP INVERTER Indoor Units FHQ60BVV1B Capacity Cooling capacity Miniu kw Standard kw 1.7 5.7 Maxiu kw 6.0 Heating capacity Miniu kw 1.7 Standard kw 7.2 Maxiu kw 8.0 EER / COP Cooling / Heating 2.65 / 2.89 Annual energy consuption 1075 Cooling / Heating Air Flow Rate Cooling High/Low ³/in Heating High/Low ³/in Sound Power Cooling High/Low dba Heating High/Low dba Sound Pressure Cooling High/Low dba Heating High/Low dba D / D 195x1160x680 27.0 17.0 / 13.0 16.0 / 13.0 55.0 / 49.0 55.0 / 49.0 39.0 / 33.0 39.0 / 33.0 Outdoor Unit RXS60F2V1B Heating Min~Max CWB Sound Pressure (Standard) Cooling dba Heating dba Sound Level (Night quiet) Sound Pressure dba Piping connections Liquid (OD)/Gas/Drain Piping Length (Maxiu) 735x825x300 48-10~46-15~18 63 49 49 46 1~/220-240/220-230V/50Hz 6.35 / 12.7 / 18 30 92

FHQ-B / RQ-B Ceiling Suspended Unit Ideal solution for shops, restaurants or offi ces without false ceilings Copact design Leaves axiu fl oor and wall space for furniture, decorations and fi ttings Easy installation and aintenance Auto-swing function ensures effi cient air and teperature distribution. Air fl ow distribution for ceiling heights up to 3.8 without loss of capacity. BRC1D52 BRC7E63 FHQ71B RQ100B 2 steps HEAT PUMP NON-INVERTER Indoor Units FHQ71BVV1B FHQ100BVV1B FHQ125BVV1B Capacity Cooling capacity Standard kw 7.1 7.1 9.8 9.8 12.2 Heating capacity Standard kw 8.0 8.0 11.2 11.2 14.5 EER / COP Cooling / Heating 2.63 / 2.81 2.68 / 2.86 2.61 / 2.71 2.66 / 2.79 2.71 / 2.81 Annual energy consuption 1350 1325 1875 1840 2255 cooling / heating D / D D / D D / E D / E D / D Air Flow Rate Cooling High/Low ³/in Heating High/Low ³/in Sound Power Cooling High/Low dba Heating High/Low dba Sound Pressure Cooling High/Low dba Heating High/Low dba 195x1160x680 195x1400x680 195x1590x680 27.0 32.0 35.0 17.0 / 14.0 24.0 / 20.0 30.0 / 25.0 17.0 / 14.0 24.0 / 20.0 30.0 / 25.0 55.0 / 51.0 58.0 / 53.0 60.0 / 55.0 55.0 / 51.0 58.0 / 53.0 60.0 / 55.0 39.0 / 35.0 42.0 / 37.0 44.0 / 39.0 39.0 / 35.0 42.0 / 37.0 44.0 / 39.0 Outdoor Unit RQ71B8V3B RQ71B8W1B RQ100B8V3B RQ100B8W1B RQ125B8W1B Heating Min~Max CWB Sound Pressure (Standard) Cooling dba Piping connections Liquid (OD)/Gas/Drain Piping Length (Maxiu) Max. internunit level difference 770x900x320 1170x900x320 84 83 103 101 108-5.0~46.0-10.0~15.0 63.0 66.0 67.0 50.0 53.0 1~/230V/50Hz 3N~/400V/50Hz 1~/230V/50Hz 3N~/400V/50Hz 9.52 / 15.9 / 26 70 0.5 93

FHQ-B / REQ-B* Ceiling Suspended Unit Ideal solution for shops, restaurants or offi ces without false ceilings Copact design Leaves axiu fl oor and wall space for furniture, decorations and fi ttings Easy installation and aintenance Auto-swing function ensures effi cient air and teperature distribution. Air fl ow distribution for ceiling heights up to 3.8 without loss of capacity. BRC1D52 BRC7E66 FHQ71B REQ71B heat pup 2 steps HEAT PUMP NON-INVERTER Indoor Units FHQ71BVV1B FHQ100BVV1B FHQ125BVV1B Capacity Cooling capacity Standard kw 7.1 7.1 9.8 9.8 12.2 Heating capacity Standard kw 8 8 11.2 11.2 14.5 EER / COP Cooling / Heating 2.63 / 2.81 2.68 / 2.86 2.61 / 2.71 2.66 / 2.79 2.71 / 2.81 Annual energy consuption 1350 1325 1875 1840 2255 cooling / heating D / D D / D D / E D / E D / D Air Flow Rate Cooling High/Low ³/in Heating High/Low ³/in Sound Power Cooling High/Low dba Heating High/Low dba Sound Pressure Cooling High/Low dba Heating High/Low dba 195x1160x680 195x1400x680 195x1590x680 27.0 32.0 35.0 17.0 / 14.0 24.0 / 20.0 30.0 / 25.0 17.0 / 14.0 24.0 / 20.0 30.0 / 25.0 55.0 / 51.0 58.0 / 53.0 60.0 / 55.0 55.0 / 51.0 58.0 / 53.0 60.0 / 55.0 39.0 / 35.0 42.0 / 37.0 44.0 / 39.0 39.0 / 35.0 42.0 / 37.0 44.0 / 39.0 Outdoor Unit REQ71B8V3B REQ71B8W1B REQ100B8V3B REQ100B8W1B REQ125B8W1B Heating Min~Max CWB Sound Pressure (Standard) Cooling dba Piping connections Liquid (OD)/Gas/Drain Piping Length (Maxiu) Max. internunit level difference * Cobination only available in Portugal, Greece, Cyprus and Malta 770x900x320 1170x900x320 83 102 100 108 10.0~46.0-10~15 65.0 70.0 53.0 57.0 1~/230V/50Hz 3N~/400V/50Hz 1~/230V/50Hz 3N~/400V/50Hz 9.52 / 15.9 / 26 50 0.5 94

FHQ-B / RZQS-C Ceiling Suspended Unit Ideal solution for shops, restaurants or offi ces without false ceilings Copact design Leaves axiu fl oor and wall space for furniture, decorations and fi ttings Easy installation and aintenance Auto-swing function ensures effi cient air and teperature distribution. Air fl ow distribution for ceiling heights up to 3.8 without loss of capacity. BRC1D52 BRC7E63 FHQ71B heat pup RZQS100,125C 2 steps HEAT PUMP INVERTER Indoor Units FHQ71BVV1B FHQ100BVV1B FHQ125BVV1B Capacity Cooling capacity Standard kw 7.1 10.0 12.5 Heating capacity Standard kw 8.0 11.2 14.0 EER / COP Cooling / Heating 2.81 / 2.81 2.41 / 2.81 2.73 / 2.82 Annual energy consuption 1,265 2,075 2,290 cooling / heating C / D E / D D / D Air Flow Rate Cooling High/Low ³/in Heating High/Low ³/in Sound Power Cooling High/Low dba Heating High/Low dba Sound Pressure Cooling High/Low dba Heating High/Low dba 195x1160x680 195x1400x680 195x1590x680 27.0 32.0 35.0 17.0 / 14.0 24.0 / 20.0 30.0 / 25.0 17.0 / 14.0 24.0 / 20.0 30.0 / 25.0 55.0 / 51.0 58.0 / 53.0 60.0 / 55.0 55.0 / 51.0 58.0 / 53.0 60.0 / 55.0 39.0 / 35.0 42.0 / 37.0 44.0 / 39.0 39.0 / 35.0 42.0 / 37.0 44.0 / 39.0 Outdoor Unit RZQS71C7V1B RZQS100C7V1B RZQS125C7V1B Heating Min~Max CWB Sound Pressure (Standard) Cooling dba Heating dba Sound Level (Night quiet) Sound Pressure dba Piping connections Liquid (OD)/Gas/Drain Piping Length (Maxiu) Max. internunit level difference 770x900x320 700x900x320 1,170x900x320 68 103-5~46-15~15.5 65 67 49 51 51 55 53 47 49 9.52 / 15.9 / 26 30 50 0.5 95

FHQ-B / RZQ-C Ceiling Suspended Unit Ideal solution for shops, restaurants or offi ces without false ceilings Copact design Leaves axiu fl oor and wall space for furniture, decorations and fi ttings Easy installation and aintenance Auto-swing function ensures effi cient air and teperature distribution. Air fl ow distribution for ceiling heights up to 3.8 without loss of capacity. BRC1D52 BRC7E63 FHQ71B RZQ100,125C heat pup 2 steps HEAT PUMP INVERTER Indoor Units FHQ71BVV1B FHQ100BVV1B FHQ125BVV1B Capacity Cooling capacity Standard kw 7.1 10.0 12.5 Heating capacity Standard kw 8.0 11.2 14.0 EER / COP Cooling / Heating 2.89 / 3.00 3.03 / 3.21 2.81 / 3.21 Annual energy consuption 1,230 1650 2225 cooling / heating C / D B / C C / C Air Flow Rate Cooling High/Low ³/in Heating High/Low ³/in Sound Power Cooling High/Low dba Heating High/Low dba Sound Pressure Cooling High/Low dba Heating High/Low dba 195x1160x680 195x1400x680 195x1590x680 27.0 32.0 35.0 17.0 / 14.0 24.0 / 20.0 30.0 / 25.0 17.0 / 14.0 24.0 / 20.0 30.0 / 25.0 55.0 / 51.0 58.0 / 53.0 60.0 / 55.0 55.0 / 51.0 58.0 / 53.0 60.0 / 55.0 39.0 / 35.0 42.0 / 37.0 44.0 / 39.0 39.0 / 35.0 42.0 / 37.0 44.0 / 39.0 Outdoor Unit RZQ71C7V1B RZQ100C7V1B RZQ125C7V1B Heating Min~Max CWB Sound Pressure (Standard) Cooling dba Heating dba Sound Level (Night quiet) Sound Pressure dba Piping connections Liquid (OD)/Gas/Drain Piping Length (Maxiu) Max. internunit level difference 770x900x320 1170x900x320 67 103-15.0~50.0-20.0~15.5 63 65 66 47 49 50 49 51 52 43 45 9.52 / 15.9 / 26 50 75 0.5 96

FHQ-B / RZQ-BW1 Ceiling Suspended Unit Ideal solution for shops, restaurants or offi ces without false ceilings Copact design Leaves axiu fl oor and wall space for furniture, decorations and fi ttings Easy installation and aintenance Auto-swing function ensures effi cient air and teperature distribution. Air fl ow distribution for ceiling heights up to 3.8 without loss of capacity. BRC1D52 BRC7E63 FHQ-B heat pup RZQ100,125B 2 steps HEAT PUMP INVERTER Indoor Units FHQ100BVV1B FHQ125BVV1B Capacity Cooling capacity Standard kw 10.00 12.50 Heating capacity Standard kw 11.20 14.00 EER / COP Cooling / Heating 3.17 / 3.11 2.81 / 3.11 Annual energy consuption 1575 2225 cooling / heating B / D C / D Air Flow Rate Cooling High/Low ³/in Heating High/Low ³/in Sound Power Cooling High/Low dba Heating High/Low dba Sound Pressure Cooling High/Low dba Heating High/Low dba 195x1400x680 195x1590x680 32.0 35.0 24.0 / 20.0 30.0 / 25.0 24.0 / 20.0 30.0 / 25.0 58.0 / 53.0 60.0 / 55.0 58.0 / 53.0 60.0 / 55.0 42.0 / 37.0 44.0 / 39.0 42.0 / 37.0 44.0 / 39.0 Outdoor Unit RZQ100B8W1B RZQ125B8W1B Heating Min~Max CWB Sound Pressure (Standard) Cooling dba Heating dba Sound Level (Night quiet) Sound Pressure dba Piping connections Liquid (OD)/Gas/Drain Piping Length (Maxiu) Max. internunit level difference 1345x900x320 106-15.0~50.0-20.0~15.5 65.0 66.0 49.0 50.0 51.0 52.0 45.0 3N~/400V/50Hz 9.52 / 15.9 / 26 75 0.5 97

FHQ-B / RKS-G Ceiling Suspended Unit Ideal solution for shops, restaurants or offi ces without false ceilings Copact design Leaves axiu fl oor and wall space for furniture, decorations and fi ttings Easy installation and aintenance Auto-swing function ensures effi cient air and teperature distribution. Air fl ow distribution for ceiling heights up to 3.8 without loss of capacity. BRC1D52 BRC7E66 FHQ-B RKS35G 2 steps 35~60 COOLING ONLY INVERTER Indoor Units FHQ35BVV1B FHQ50BVV1B Capacity Cooling capacity Miniu kw Standard kw Maxiu kw EER Noinal Annual energy consuption cooling Air Flow Rate Cooling High/Low ³/in Sound Power Cooling High/Low dba Heating High/Low dba Sound Pressure Cooling High/Low dba 1.4 1.7 3.4 5.0 3.7 5.6 3.24 2.73 525 915 A D 195x960x680 195x960x680 24.0 25.0 13.0 / 10.0 13.0 / 10.0 53.0 / 48.0 54.0 / 49.0 53.0 / 48.0 54.0 / 49.0 37.0 / 32.0 38.0 / 33.0 Outdoor Unit RKS35G2V1B RKS50G2V1B Sound Pressure (Low) Cooling dba Sound Pressure (High) Cooling dba Piping connections Liquid (OD)/Gas/Drain Piping Length (Maxiu) 550x765x285 735x825x300 34 48-10~46-10~46 62 61 44 44 48 48 6.35 / 9.52 / 18 6.35 / 12.7 / 18 20 30 98

FHQ-B / RKS-F Ceiling Suspended Unit Ideal solution for shops, restaurants or offi ces without false ceilings Copact design Leaves axiu fl oor and wall space for furniture, decorations and fi ttings Easy installation and aintenance Auto-swing function ensures effi cient air and teperature distribution. Air fl ow distribution for ceiling heights up to 3.8 without loss of capacity. BRC1D52 BRC7E66 FHQ60B RKS60F 2 steps 60 standard COOLING ONLY Indoor Units Capacity Cooling capacity Miniu kw Standard kw Maxiu kw EER Noinal Annual energy consuption cooling Air Flow Rate Cooling High/Low ³/in Sound Power Cooling High/Low dba Heating High/Low dba Sound Pressure Cooling High/Low dba INVERTER FHQ60BVV1B 1.7 5.7 6.0 2.65 1075 D 195x1160x680 27.0 17.0 / 13.0 55.0 / 49.0 55.0 / 49.0 39.0 / 33.0 Outdoor Unit Sound Pressure (Standard) Cooling dba Piping connections Liquid (OD)/Gas/Drain Piping Length (Maxiu) RKS60F2V1B 735x825x300 47-10~46 63 49(H) - 46(SL) 6.35 / 12.7 / 18 30 99

FHQ-B / RN-E Ceiling Suspended Unit Ideal solution for shops, restaurants or offi ces without false ceilings Copact design Leaves axiu fl oor and wall space for furniture, decorations and fi ttings Easy installation and aintenance Auto-swing function ensures effi cient air and teperature distribution. Air fl ow distribution for ceiling heights up to 3.8 without loss of capacity. BRC1D52 BRC7E66 FHQ50B RN50,60E 2 steps 50~60 standard COOLING ONLY NON-INVERTER Indoor Units FHQ50BVV1B FHQ60BVV1B Noinal Capacity Cooling capacity Standard kw 5.0 5.7 Miniu kw - - Maxiu kw - - EER Noinal 2.73 2.73 Annual energy consuption 915 1075 cooling D D Air Flow Rate Cooling High/Low ³/in Sound Power Cooling High/Low dba Heating High/Low dba Sound Pressure Cooling High/Low dba 195x960x680 195x1160x680 25.0 27.0 13.0 / 10.0 17.0 / 13.0 54.0 / 49.0 55.0 / 49.0 54.0 / 49.0 55.0 / 49.0 38.0 / 33.0 39.0 / 33.0 Outdoor Unit RN50E3V1B RN60E3V1B Sound Pressure Cooling dba Piping connections Liquid (OD)/Gas/Drain Piping Length (Maxiu) Max. internunit level difference 735x825x300 735x825x300 47 47-10.0~46.0-10.0~46.0 61.0 63.0 47.0 49.0 6.35 / 12.7 / 18 6.35 / 12.7 / 18 30 30 20 20 100

FHQ-B / RR-B Ceiling Suspended Unit Ideal solution for shops, restaurants or offi ces without false ceilings Copact design Leaves axiu fl oor and wall space for furniture, decorations and fi ttings Easy installation and aintenance Auto-swing function ensures effi cient air and teperature distribution. Air fl ow distribution for ceiling heights up to 3.8 without loss of capacity. BRC1D52 BRC7E66 FHQ71B RR100B 2 steps standard COOLING ONLY NON-INVERTER Indoor Units FHQ71BVV1B FHQ100BVV1B FHQ125BVV1B Capacity Cooling capacity Standard kw 7.10 7.10 9.80 9.80 12.20 EER Noinal 2.63 2.68 2.61 2.66 2.71 Annual energy consuption 1350 1325 1875 1840 2255 cooling D D D Air Flow Rate Cooling High/Low ³/in Sound Power Cooling High/Low dba Heating High/Low dba Sound Pressure Cooling High/Low dba 195x1160x680 195x1400x680 195x1590x680 27.0 32.0 35.0 17.0 / 14.0 24.0 / 20.0 30.0 / 25.0 55.0 / 51.0 58.0 / 53.0 60.0 / 55.0 55.0 / 51.0 58.0 / 53.0 60.0 / 55.0 39.0 / 35.0 42.0 / 37.0 44.0 / 39.0 Outdoor Unit RR71B8V3B RR71B8W1B RR100B8V3B RR100B8W1B RR125B8W1B Sound Pressure (Standard) Cooling dba Piping connections Liquid (OD)/Gas/Drain Piping Length (Maxiu) Max. internunit level difference 770x900x320 1170x900x320 83 81 102 99 106-15.0~46.0 63.0 66.0 67.0 50.0 53.0 1~/230V/50Hz 3N~/400V/50Hz 1~/230V/50Hz 3N~/400V/50Hz 9.52 / 15.9 / 26 70 0.5 101

102

Roof Top & Packaged Systes A range of high perforance, low energy consuption air cooled packaged roof top units is produced by Daikin for superarket, warehouse, factory, hotel, hospital, cinea and large store applications. Heat pup and cooling only plug and play versions are easy to install and available as fully integrated systes coprising copressor, evaporator and condensing units for air transission through ductwork to the conditioned space. PACKAGED SYSTEMS FDQ-B / RZQ-C 104 FDYP-B / RYP-B 105 FDYP-B / RP-B 106 ROOF TOP UNITS UATYP-A 108 UATP-A 109 103

FDQ-B / RZQ-CY1 Concealed Ceiling Unit Sli design for fl exible installation Ideal for use in larger areas Blends unobtrusively with any interior décor: only the suction and discharge grilles are visible Maxiu external static pressure (ESP) ranges fro 150 till 250Pa Optiu air distribution BRC1D52 FDQ200,250B RZQ200,250C 2 steps: FDQ250, 3 steps: FDQ200 standard heat pup HEAT PUMP INVERTER Indoor Units FDQ200B8V3B9 FDQ250B8V3B9 Capacity Cooling capacity Standard kw 20.0 24.1 Heating capacity Standard kw 23.0 26.4 EER / COP Cooling / Heating 3.21 / 3.41 2.81 / 3.21 Annual energy consuption 3.115 4.290 cooling / heating A / B C / C Air Flow Rate Cooling Mediu ³/in Heating Mediu ³/in Sound Power Cooling Mediu dba Sound Pressure Cooling High dba Heating Low dba 450x1400x900 89.0 94.0 69.0 89.0 69.0 89.0 81.0 82.0 45.0 47.0 45.0 47.0 1~/230V/50Hz Outdoor Unit RZQ200C7Y1B RZQ250C7Y1B Heating Min~Max CWB Sound power dba Sound pressure dba Piping connections Liquid (OD)/Gas Piping Length (Maxiu) 1680x930x765 183 184-5.0~46.0-15.0~15.0 78 57 3N~/380-415V/50Hz 9.5 / 22,2 100 104

FDYP-B / RYP-B Concealed Ceiling Unit Sli design for fl exible installation Ideal for use in larger areas Blends unobtrusively with any interior décor Maxiu external static pressure (ESP) ranges fro 150 till 250Pa Optiu air distribution BRC1D52 FDYP200,250B 2 steps: FDYP250, 3 steps: FDYP125-200 RYP250B twin application only heat pup HEAT PUMP NON-INVERTER Indoor Units FDYP200B8V19 FDYP250B8V19 Capacity Cooling capacity Standard kw 19.50 25.00 Heating capacity Standard kw 23.10 27.00 EER / COP Cooling / Heating Annual energy consuption Air Flow Rate Cooling Mediu ³/in Heating Mediu ³/in Sound Power Cooling High dba Heating High dba Sound Pressure Cooling High dba Heating High dba 2.24/3.04 2.45/3.08 4,345 5,100 450x1400x900 89.0 94.0 69.0 89.0 69.0 89.0 81.0 82.0 81.0 82.0 45.0 47.0 45.0 47.0 R-407C 230V/50Hz Outdoor Unit RYP200B7W1 RYP250B7W1 Heating Min~Max CWB Sound Pressure (Standard) Cooling dba Heating dba Piping connections Liquid (OD)/Gas/Drain Piping Length (Maxiu) 1220x1290x700 1440x1290x700 196 210-5~46-10~15 77.0 57.0 57.0 R-407C 400V/50Hz 12.7 / 28.6 / 26 15.9 / 28.6 / 26 50 105

FDYP-B / RP-B Concealed Ceiling Unit Sli design for fl exible installation Ideal for use in larger areas Blends unobtrusively with any interior décor Maxiu external static pressure (ESP) ranges fro 150 till 250Pa Optiu air distribution BRC1D52 FDYP200,250B 2 steps: FDYP250, 3 steps: FDYP125-200 RP250B twin application only COOLING ONLY NON-INVERTER Indoor Units FDYP200B8V19 FDYP250B8V19 Capacity Cooling capacity Standard kw 20.00 25.00 EER Noinal 2.30 2.33 COP Noinal - - EER / COP Cooling / Heating - - Annual energy consuption Air Flow Rate Cooling Mediu ³/in Heating Mediu ³/in Sound Power Cooling High dba Heating High dba Sound Pressure Cooling High dba Heating High dba 4,355 5,370 450x1400x900 89.0 94.0 69.0 89.0 69.0 89.0 81.0 82.0 81.0 82.0 45.0 47.0 45.0 47.0 R-407C 230V/50Hz Outdoor Unit RP250B7W1 RP200B7W1 Sound Pressure (Standard) Cooling dba Piping connections Liquid (OD)/Gas/Drain Piping Length (Maxiu) 1220x1290x700 1440x1290x700 194 206-5~46 77.0 56.0 R-407C 400V/50Hz 12.7 / 28.6 / 26 15.9 / 28.6 / 26 50 106

107

UATYP-A Rooftop Plug and Play installation: the single unit confi guration requires no additional piping work as both the indoor and outdoor sides are preconnected. is factory pre-charged to ensure clean and effi cient operation. The air volue and static pressure required can be adjusted according to the requireent because of the use of a belt driven fan. The fl at top design of the unit allows for axiu utilization of warehouse and container space. High effi ciency and reliable scroll copressor. Convertible: fan can be ounted in two directions (Class 240-280-320-450-560). Coil with anti-corrosion treatent. UATYP-A HEAT PUMP NON-INVERTER Outdoor Units UATYP180AMY1 UATYP240AMY1 UATYP280AMY1 UATYP320AMY1 UATYP450AMY1 UATYP560AMY1 UATYP700AMY1 UATYP850AMY1 UATYPC10AMY1 UATYPC12AMY1 Capacity Cooling Miniu kw 16.705 21.101 25.790 29.307 43.668 55.684 67.406 82.939 101.110 109.609 Heating Noinal kw 20.222 22.566 29.89 35.755 46.891 67.406 74.733 92.317 102.290 126.314 EER Cooling 2.44 2.51 2.38 2.28 2.64 2.63 2.31 2.17 2.34 2.27 COP Heating 3.06 2.99 3.05 3.11 2.98 3.32 2.85 2.65 2.45 2.70 Air Flow Rate evaporator Cooling ³/in 51 80 100 102 160 190 226 263 312 354 External Static Pressure Pa 98 196 294 Condensation Drain Size Diaeter (OD) 25.4 Casing Colour Light Grey Material Electro galvanised ild steel Diensions Unit HxWxD 1000x1100x1530 1200x1990x1800 1735x2250x2800 1974x2252x3180 Unit 320 385 415 440 700 800 12000 1350 1510 1600 Air Flow Rate condensor Cooling ³/in 127 160 283 320 566 Operation Range Cooling Min-Max CDB 20 C 46 C Heating Min-Max CWD -15 C 20 C Sound Level Sound Power dba 63 65 66 68 70 70 74 74 80 80 R-407C 3~/50Hz/380-415V 108

UATP-A Rooftop Plug and Play installation: the single unit confi guration requires no additional piping work as both the indoor and outdoor sides are preconnected. is factory pre-charged to ensure clean and effi cient operation. The air volue and static pressure required can be adjusted according to the requireent because of the use of a belt driven fan. The fl at top design of the unit allows for axiu utilization of warehouse and container space. High effi ciency and reliable scroll copressor. Convertible: fan can be ounted in two directions (Class 240-280-320-450-560). Coil with anti-corrosion treatent. UATP-A COOLING ONLY NON-INVERTER Outdoor Units UATP180AMY1 UATP240AMY1 UATP280AMY1 UATP320AMY1 UATP450AMY1 UATP560AMY1 UATP700AMY1 UATP850AMY1 UATPC10AMY1 UATPC12AMY1 Capacity Cooling Miniu kw 17.291 21.101 27.842 32.238 41.030 55.684 67.406 82.939 97.007 121.624 Noinal kw 5.89 8.70 11.60 12.18 17.20 25.10 28.70 40.16 41.87 48.80 EER Cooling 2.94 2.43 2.40 2.65 2.39 2.22 2.35 2.07 2.32 2.49 Air Flow Rate evaporator Cooling ³/in 51 80 100 102 160 190 227 263 312 354 External Static Pressure Pa 98 196 294 Condensation Drain Size Diaeter 25.4 Casing Colour Light Grey Material Electro galvanised ild steel Diensions HxWxD 1000x1100x1530 1000x1300x1530 1200x1990x1670 1735x2250x2800 1974x2252x3180 Unit 295 370 400 425 665 765 1200 1350 1510 1600 Air Flow Rate condensor Cooling ³/in 127 160 227 320 566 Operation Range Cooling Min-Max CDB 20 C - 46 C Sound Level Sound Power dba 63 65 66 68 70 70 74 74 80 80 R-407C 3~/50Hz/380-415V 109