DEDICATED VERTICAL/WALL MOUNT

Similar documents
Field Installed Options: * Louvered or non-louvered ceiling access panels. * Time delay relay.

MX Series Indoor Modular Blowers Electric Heat, Hot Water Heat, or No Heat

CWA4 Chilled & Hot Water Fan Coil

CWA2 Chilled Water Fan Coil With or Without Electric Heat 2-Pipe Heat / Cool Fan Coil 18,000-60,000 BTUH

INSTALLATION AND OWNERS MANUAL

FF1DNA, FF1DNE FAN COIL UNITS. Sizes 018, 024, 030. Form No. PDS FF1D.18.3 FEATURES FF1D

1-1/2 THRU 2-1/2 TONS SPLIT SYSTEM FWM Series

MHCCW Chilled Water Ceiling Concealed With 5kW Electric Heat 2-Pipe Heat / Cool Fan Coil 30,000 BTUH

BCE4 PRODUCT SPECIFICATIONS ENHANCED AIR HANDLER WITH VARIABLE SPEED APPLICATION INSTALLATION CABINET COMPONENTS CONTROLS WARRANTY

Product Data. FF1DNA, FF1DNE Fan Coil Units. Sizes 018 thru 030 FEATURES/BENEFITS

MHCCW Chilled Water Ceiling Concealed Without Electric Heat 2-Pipe Heat / Cool Fan Coil 18,000 BTUH

MERIT Series R-410A - Upflow / Horizontal

Fan Coils & Air Handlers Product Catalog

MERIT Series R-410A - Upflow / Horizontal

MERIT SERIES Up Flow / Horizontal

CROWN. Boiler Co. Santa-Fe Series. Hydronic Air Handlers INSTALLATION, OPERATION & MAINTENANCE INSTRUCTIONS

MHNCCW (4-Pipe) Chilled/Hot Water Ceiling Concealed 208/230V 4-Pipe Heating & Cooling Fan Coil 12,000 BTUH

MHNCCX DX with Hot Water Heat Ceiling Concealed 4-Pipe Heat / Cool Fan Coil 12,000-36,000 BTUH

DH SERIES HORIZONTAL DIRECT DRIVE CHILLED WATER/DX AIR UNITS. OPTIONAL ACCESSORIES Two Row Hot Water Coil

K*ES120 DESCRIPTION TECHNICAL GUIDE SPLIT-SYSTEM EVAPORATOR BLOWERS 10 NOMINAL TONS EER 8.5 ACCESSORIES FIELD INSTALLED TABLE 1: ARI RATINGS*

AllStyle Coil Company, LP 7037 Brittmore Houston, TX Phone Fax

RE9X Series Downflow, Upflow Electric Furnaces

Air Handler Installation Instructions Water Lines

maintenance should only be performed by a trained, qualified person. Consumer service is recommended only for filter replacement.

FEM4X. Product Specifications FAN COILS /14/15

DVPVC. Multi-Position, Variable-Speed Air Handler. Comfortnet - Compatible ECM-based Inverter-tuned Internal TXV

E4EB-xxx-H Series Downflow, Upflow Electric Furnaces

Product Data. FPMA Sizes 018 thru 036 FPMB Sizes 018 thru 030 Base Series Horizontal Fan Coil

G34M Bulletin #69/ August 2003

ACCESSORY KIT INSTALLATION INSTRUCTIONS

VertiCool Aurora Engineering Guide

CATALOG. SKYPAK Self-Contained Heating/Cooling Units

E2 Series. Downflow, Upflow Electric Furnaces TECHNICAL SPECIFICATIONS. Features and Benefits

HIGH EFFICIENCY AIR HANDLER

Advance Product Data. Features/Benefits. 42WKN Hydronic Fan Coil Units

AVPTC Multi-Position, Internal Txv

PAJ3. Product Specifications

Product Specifications NEW OPTION AVAILABLE: AUTOSPEED 24V CONTROL PACKAGE

PC SERIES 50 Hertz PRODUCT SPECIFICATIONS. Self-Contained Packaged Air Conditioners. 4 and 5 Ton [14.1 kw to 17.6 kw]

AVPTC Multi-Position, Internal Txv

15 SEER, PACKAGE AIR CONDITIONING UNITS, 2-5 TONS Single Phase, 208/230 V, 60 Hz COOLING

WAHL A Product Specifications

MHWW-24-H-1 Chilled/Hot Water Hi-Wall Fan Coil 2-Pipe Heat / Cool Fan Coil 24,000 BTUH

MHWW-09-H-1 Chilled/Hot Water Hi-Wall Fan Coil 2-Pipe Heat / Cool Fan Coil 9,000 BTUH

CB18/CBS18 Bulletin # September 1994 Supersedes August 1986

UPFLOW WALL / CLOSET FAN COIL AIR CONDITIONERS ENGINEERING GUIDE

Product Specifications NEW OPTION AVAILABLE: AUTOSPEED 24V CONTROL PACKAGE

Product Data PF1MNC DIRECT EXPANSION FAN COIL SIZES 018 THRU 061 FEATURES/BENEFITS AVAILABLE SIZES: 18,000 to 61,000 BTU unit ELECTRICAL RANGE:

REM4P, REM4X. Product Specifications

SKYPAK II, 3 Ton Series, gives you a

49 x 21 x 22. (1261 x 448 x 560) (1261 x 448 x 560) 59 x 24 x 22. (1357 x 537 x 560) (1261 x 537 x 560) (1261 x 537 x 560) (1357 x 627 x 560)

Commercial High-Efficiency Condensing Units

E3EB-xxx-H Series Downflow, Upflow Electric Furnaces

DVPEC. Multi-Position, Variable-Speed air handler. Comfortnet Compatible ECM-based Internal EEV, Inverter-tuned 2 to 5 Tons

Commercial High-Efficiency Condensing Units

SPXB-HW Series Single Package Vertical Unit Cooling with Hot Water Heat 1 through 2 tons, up to 47,800 BTUH Heating

ASPT Series. Multi-Position, Multi-Speed, ECM-Based Air Handler with Internal TXV 1½ to 5 Tons. Contents. Product Features

The Premium Quality Fan Coil Units for Vertical, Horizontal (Left or Right) Application with Direct Expansion, Hydronic or Electric Heat

Ameristar SUBMITTAL M4AH4E26B1A00AA. 2.0 Ton Multi-position Air Handler M4AH4E26B1A00AA TAG:

TECHNICAL GUIDE. Description SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS YD360, 480 & THRU 50 NOMINAL TONS YTG-B-0811

ASPT Series. Multi-Position, Multi-Speed, ECM-Based Air Handler with Internal TXV 1½ to 5 Tons. Contents. Product Features

ARPT Series. Multi-Position. 1½ to 5 Tons. Internal TXV, Multi-Speed PSC Motor

Product Data. 50HS Single-Package Heat Pumps to 5 Nominal Tons

VertiCool CLASSIC. Engineering Guide. Effective March Air-Cooled, Water-Cooled, Chilled Water and Water Source Heat Pump

C13-Series Engineering Guide

CFFWA4P-16-1-U Chilled/Hot Water Universal Mount Fan Coil (4-Pipe) 4-Pipe Heat / Cool Fan Coil 48,000 BTUH

CFFWA4P-12-1-U Chilled/Hot Water Universal Mount Fan Coil (4-Pipe) 4-Pipe Heat / Cool Fan Coil 36,000 BTUH

IMPORTANT CB26UH CBX26UH. Service Literature. CB26UH and CBX26UH Series Table of Contents. Model Number Information... 2

SPLIT-SYSTEM EVAPORATOR BLOWERS K2EU060, K4EU090, K3EU120 & K1EU180 5 Thru 15 Nominal Tons DESCRIPTION ACCESSORIES FIELD INSTALLED

AVPTC Multi-Position, Internal Txv

Product Data PF4MNB DIRECT EXPANSION FAN COIL FOR R -410A REFRIGERANT SIZES 019 THRU 061 FEATURES/BENEFITS AVAILABLE SIZES:

AVPTC. Multi-Position, Variable-Speed ECM Based Air Handler with Internal TXV ComfortNet Compatible 1½ to 5 Tons. Contents.

TECHNICAL GUIDE HIGH EFFICIENCY, STANDARD ECM VERTICAL WALL MOUNT AIR HANDLERS FOR USE WITH SPLIT-SYSTEM COOLING & HEAT PUMPS MODELS: EWX*18-36

CFFWA4P-08-1-U Chilled/Hot Water Universal Mount Fan Coil (4-Pipe) 4-Pipe Heat / Cool Fan Coil 24,000 BTUH

WH1T SERIES Constant Torque Motor (ECM) Efficiencies up to 14 SEER. FORM NO. H REV. 1 Supersedes Form No. G Rev. 3

ARPT Series. Multi-Position, Multi-speed Air Handler with Internal TXV and PSC Motor 2 to 5 Tons. Contents. Product Features

UP to 14.5 SEER, PACKAGE AIR CONDITIONER UNIT, 2 to 5 TONS 208/230 Volt, 1 phase, 60 Hz REFRIGERATION CIRCUIT

AIR HANDLERS AIR HANDLERS

ENGINEERING GUIDE. Water-Cooled Self-Contained Units C-Series, Vertical

FXM4X. Product Specifications FAN COILS FXM4X

Product Data PF4MNA DIRECT EXPANSION FAN COIL FOR R -410A REFRIGERANT SIZES 018 THRU 061 FEATURES/BENEFITS AVAILABLE SIZES:

TECHNICAL SPECIFICATIONS

High Heat COP. High/Low Stage

ARPT Series. Multi-Position. 2 to 5 Tons. Internal TXV, Multi-Speed PSC Motor

TECHNICAL SPECIFICATIONS

HIGH EFFICIENCY AIR HANDLER

49 5/8 x 17 5/8 x 22 1/16 (1261 x 448 x 560) 49 5/8 x 17 5/8 x 22 1/16 (1261 x 448 x 560) 53 7/16 x 21 1/8 x 22 1/16 (1357 x 537 x 560)

ASHRAE 90.1 EFFICIENCY PACKAGE AIR CONDITIONER UNIT MBtuh

COMMERCIAL PACKAGED HEAT PUMP AIR HANDLER UNITS, 6 20 TONS

FEATURES. Gas Furnace provides the efficiency customers want with 78% Annual Fuel Utilization Efficiency (AFUE).

VariCool VAV Engineering Guide

Ruud Standard Efficiency Air Handler

PAR5. Product Specifications

EarthLinked AVN Series Air Handlers Installation Manual

36,000-62,000 BTUH Nominal Capacity

TECHNICAL GUIDE MODELS: MV MODULAR VARIABLE SPEED AIR HANDLERS FOR USE WITH SPLIT SYSTEM COOLING & HEAT PUMP DESCRIPTION FEATURES

PAD3. Product Specifications. 13 SEER PACKAGE AIR CONDITIONER, 2 to 5 TONS Single Phase, 208/230 V, 60 Hz REFRIGERATION CIRCUIT

ACNF Series. Ceiling-Mount Air Handlers 1½ to 2½ Tons

DAVE LENNOX SIGNATURE COLLECTION R-410A Ready - Multi-Position - Variable Speed

HIGH EFFICIENCY TWO-STAGE ECONET ENABLED AIR HANDLER

Transcription:

WCW-Chilled Water Cooling Electric or Hot Water Heating Description: The B/S/H, & WCW air handlers with electric or hot water heating are designed for recessed mounting in a wall, hanging on the wall, or in a closet. These units are designed for the vertical position only. The B/S/H 02 units will handle up to 1000 CFM air flow and from 1.5 to 2.5 nominal tons of DX cooling, and up to 10 KW electric heat. The B/S/H 03 units will handle up to 1200 CFM air flow and up to nominal 3 tons of DX cooling and up to 15 KW electric heat. The WCW units will handle up to 1200 CFM air flow and up to 3 tons of chilled water cooling, with electric or hot water heat. The "B/S" units are used with electric heat The "H" series units are used with hot water heat. The WCW units are used wirh either electric or hot water heat. Standard Features: * Vertical design, recessed "in-the-wall" or closet mounted. * Prewired for cooling, heating and heat pump operation. * Heavy gauge embossed galvanized steel cabinet. * 40 VA transformer. * Includes throwaway filter. * Electric heat models are 208/230/1/60. * Hot water heat models qre 115/1/60. * 1 Foil faced insulation. * Slide out blower for easy maintenance. * Automatic temperature reset limit/fan relay/sequencer. * Removeable bottom panel. * Low voltage connection inside blower compartment. * Hot water heat models include circulating pump with relay, water lines are stubbed out inside cabinet with mechanical sweat union connections. * Hot water heat units include water side check valve, and manual purge valves. * Suitable for 0 inch clearance to combustible materials. Electric Heat Unit Shown Field Installed Options: * Paintable, white "picture frame" panel door for wall recessed or wall hung applications. * Embossed, louvered coil door for wall hung applications. * Hanging brackets for wall hung applications. * Bottom return air panel. Factory Installed Options: * Circuit Breaker on electric heat models 10 KW and smaller * Pump timer for hydronic units. Hydronic Heat Unit Shown Form: BSH0203/WCW-070106-1

PRODUCT NOMENCLATURE AIR HANDLER TYPE B-With Circuit Breaker S-Without Circuit Breaker H-Hot Water Heat WCW- Chilled Water Cooling B 02 34 5 B 1 A C SERIES (02) - Wall Mount 1.5-2.5 Tons (03) - Wall Mount 3.0 Tons BLOWER (34) - 1/3 HP - 208/240/1-10x7 (37) - 1/3 HP - 115/1-10x7 (42) - 1/3 HP - 208/240/1-10x7 (B/S03) (45) - 1/4 HP - 208/240/1-10x6 (46) - 1/4 HP - 115/1-10x6 (49) - 1/3 HP - 115/1-10x8 HEATING CAPACITY (10) - Indicates KW Electric Heating B/S Models Only (26) - Indicates BTUH Hot Water Heating H Models Only UNIT VOLTAGE A - 115 Volts Single Phase (H) Models Only B - 208/240 Volts Single Phase (B/S) Models Only TIME DELAY RELAY 1 - With Time Delay Relay TDR 0 - Without Time Delay Relay TDR INSULATION A - 1/2" Insulation B - 1" Insulation VERSION C - (Current) Plastic Drain Pans Form: BSH0203/WCW-070106-2

PRODUCT NOMENCLATURE EVAPORATOR COIL C S 030 S 464 X COIL C = Cooling/Heat Pump TYPE S = Slant Coil NOMINAL CAPACITY 18 = 18000 BTUH 24 = 24000 BTUH 30 = 30000 BTUH 36 = 36000 BTUH SLAB CONFIGURATION S = 1 Slab (Single Slab Coil) SLAB CODE Factory Use METERING DEVICE See Specification Sheets Form: BSH0203/WCW-070106-3

WCW-Chilled Water Cooling Electric or Hot Water Heating PHYSICAL DIMENSIONS Model Number B/S/H-02, 03 and 18/24WCW B/S/H-03 and 30/36WCW A B C D E 22 15-3/4 14 11 39 22 18-3/4 14 11 44-1/4 A C B D A C D B E 39.00 TOP VIEW FRONT VIEW SIDE VIEW GENERAL SPECIFICATIONS Model Number Nominal Blower Heating Filter Max.Shp. Qty. Per Tons Code 0.20" Capacity Size Weight Truckload B/S-02 1.5-2.0 45 850 0-10 KW 15X20X1 108 200 B/S-02 2.5 34 1000 0-10 KW 15X20X1 108 200 B/S-03 3.0 42 1200 0-15 KW 16X20X1 118 200 H-02 1.5-2.0 46 800 26-37000 15X20X1 115 200 H-02 2.5 37 985 34-39000 15X20X1 115 200 H-03 3.0 49 1125 43000 16X20X1 125 200 18/24WCW 1.5-2.0 45 850 0-10 KW 16X20X1 115 200 30/36WCW 2.5-3.0 42 1200 0-15 KW 20X20X1 125 200 18/24WCW-HW 1.5-2.0 45 850 26-37000 16X20X1 115 200 30/36WCW-HW 2.5-3.0 42 1200 34-43000 20X20X1 125 200 Heating Capacity For "B" & "S" Models Is Expressed In Electric KW Heating Capacity For "H" Models Is Expressed In 1000 BTUH Form: BSH0203/WCW-070106-4

FAN DATA "B/S" SERIES Model Number Nominal Tons B/S02-34 2.5 Motor HP @ 230/1 B/S02-45 1.5-2.0 1/4 1/3 B/S03-42 3 1/3 Blower Speed 0.10" 0.20" 0.30" 0.40" 0.50" High 890 850 830 810 800 Medium 870 830 800 770 750 Low 830 780 740 710 - High 1050 1000 950 920 900 Medium 1020 970 930 900 870 Low 1000 950 900 870 830 High 1250 1200 1120 1060 1000 Medium 1070 1020 970 920 860 Low 900 870 840 790 720 FAN DATA "H" SERIES Model Number H02-46-26 H02-46-30 Nominal Tons Motor HP @ 115/1 1.5-2.0 1/4 H02-46-36 1.5-2.0 1/4 H02-37-34 2.5 1/3 H02-37-39 2.5 1/3 H03-49-43 3 1/3 Blower Speed 0.10" 0.20" 0.30" 0.40" 0.50" High 820 800 770 730 710 Medium 800 760 730 690 650 Low 760 730 680 650 - High 795 780 750 700 690 Medium 770 720 700 660 640 Low 730 700 660 620 - High 1040 985 940 920 900 Medium 1020 970 930 900 870 Low 1010 950 900 870 830 High 1000 960 920 880 840 Medium 980 930 880 850 800 Low 960 900 850 810 770 High 1234 1150 1110 1080 1050 Medium 1100 1055 1010 950 905 Low 1080 1015 975 915 - CFM Is Expressed For Nominal Tonnage With Dry Coil - Use 0.96 As Approximate Wet Coil Correction Factor Form: BSH0203/WCW-070106-5

WCW Series Chilled Water Cooling Electric or Hot Water Heat FAN DATA "WCW" SERIES WITH ELECTRIC HEAT Model Number Nominal Tons Motor HP @ 230/1 Blower Speed 0.10" 0.20" 0.30" 0.40" 0.50" 18/24WCW 1.5-2.0 1/4 30/36WCW 2.5-3.0 1/3 High 890 850 830 810 800 Medium 870 830 800 770 750 Low 830 780 740 710 - High 1250 1200 1120 1060 1000 Medium 1070 1020 970 920 860 Low 900 870 840 790 720 FAN DATA "WCW" SERIES WITH HOT WATER HEAT Model Number Nominal Tons Motor HP @ 115/1 Blower Speed 0.10" 0.20" 0.30" 0.40" 0.50" 18/24WCW-HW 1.5-2.0 1/4 30WCW-HW 2.5 1/3 36WCW-HW 3.0 1/3 High 820 800 770 730 710 Medium 800 760 730 690 650 Low 760 730 680 650 - High 1000 960 920 880 840 Medium 980 930 880 850 800 Low 960 900 850 810 770 High 1234 1150 1110 1080 1050 Medium 1100 1055 1010 950 905 Low 1080 1015 975 915 - CFM Is Expressed For Nominal Tonnage With Dry Coil - Use 0.96 As Approximate Wet Coil Correction Factor Form: BSH0203/WCW-070106-6

WCW-Chilled Water Cooling Electric or Hot Water Heating Model Number B/S02-45-00-C B/S02-45-03-C B/S02-45-05-C B/S02-45-08-C B/S02-45-10-C B/S02-34-00-C B/S02-34-03-C B/S02-34-05-C B/S02-34-08-C B/S02-34-10-C B/S03-42-00-C B/S03-42-03-C B/S03-42-05-C B/S03-42-08-C B/S03-42-10-C B03-42-12-C B03-42-15-C ELECTRICAL DATA "B/S" SERIES WITH ELECTRIC HEAT Motor Motor KW Electric Heat Min. Circuit Ampacity Max. Fuse Size HP Amps 240/1 208/1 240/1 208/1 240/1 208/1 1/4 1.7 0.0 0.0 2.1 1.9 15.0 15.0 1/4 1.7 3.0 2.3 18.4 15.4 25.0 25.0 1/4 1.7 5.0 3.8 29.0 25.0 30.0 25.0 1/4 1.7 8.0 6.0 44.0 39.0 45.0 40.0 1/4 1.7 10.0 7.5 55.0 48.0 60.0 50.0 1/3 2.8 0.0 0.0 3.5 3.2 15.0 15.0 1/3 2.8 3.0 2.3 19.8 16.9 25.0 25.0 1/3 2.8 5.0 3.8 30.0 27.0 30.0 30.0 1/3 2.8 8.0 6.0 46.0 40.0 50.0 40.0 1/3 2.8 10.0 7.5 56.0 49.0 60.0 50.0 1/3 2.8 0.0 0.0 3.5 3.2 15.0 15.0 1/3 2.8 3.0 2.3 19.8 16.9 25.0 25.0 1/3 2.8 5.0 3.8 30.0 27.0 30.0 30.0 1/3 2.8 8.0 6.0 45.0 40.0 50.0 40.0 1/3 2.8 10.0 7.5 56.0 29.0 60.0 50.0 1/3 2.8 12.0 9.0 35.0/32.0 31.0/28.0 35.0/35.0 35.0/30.0 1/3 2.8 15.0 11.3 32.0/53.0 29.0/46.0 35.0/60.0 30.0/50.0 ELECTRICAL DATA "WCW" SERIES WITH ELECTRIC HEAT Model Motor Motor KW Electric Heat Min. Circuit Ampacity Max. Fuse Size Number HP Amps 240/1 208/1 240/1 208/1 240/1 208/1 18/24WCW-00-C 1/4 1.7 0.0 0.0 2.1 1.9 15.0 15.0 18/24WCW-03-C 1/4 1.7 3.0 2.3 18.4 15.4 25.0 25.0 18/24WCW-05-C 1/4 1.7 5.0 3.8 29.0 25.0 30.0 25.0 18/24WCW-08-C 1/4 1.7 8.0 6.0 44.0 39.0 45.0 40.0 18/24WCW-10-C 1/4 1.7 10.0 7.5 55.0 48.0 60.0 50.0 30/36WCW-00-C 1/3 2.8 0.0 0.0 3.5 3.2 15.0 15.0 30/36WCW-03-C 1/3 2.8 3.0 2.3 19.8 16.9 25.0 25.0 30/36WCW-05-C 1/3 2.8 5.0 3.8 30.0 27.0 30.0 30.0 30/36WCW-08-C 1/3 2.8 8.0 6.0 45.0 40.0 50.0 40.0 30/36WCW-10-C 1/3 2.8 10.0 7.5 56.0 29.0 60.0 50.0 30/36WCW-12-C 1/3 2.8 12.0 9.0 35.0/32.0 31.0/28.0 35.0/35.0 35.0/30.0 30/36WCW-15-C 1/3 2.8 15.0 11.3 32.0/53.0 29.0/46.0 35.0/60.0 30.0/50.0 ELECTRICAL DATA "H" AND "WCW" SERIES WITH HW HEAT Model Motor Motor @ 115/1/60 Number HP Amps MCA MOCP H02-46 1/4 3.2 4.0 10 H-02-37 1/3 6.2 7.8 15 H-03-49 1/3 6.2 7.8 15 18/24WCW 1/4 3.2 4.0 10 30/36WCW 1/3 6.2 7.8 15 Form: BSH0203/WCW/070106-7

Model Number 18WCW 24WCW 30WCW 36WCW WCW-Chilled Water Cooling Electric or Hot Water Heating "WCW" SERIES CHILLED WATER COOLING CAPACITY Cooling Capacity @ EDB/EWB/EWT WPD 80/67/45 80/67/42 CFM GPM (Ft.Wtr) Total Sensible Total Sensible 14,125 12,430 15,375 13,030 2.0 1.1 17,225 13,940 18,995 14,685 3.0 2.2 19,590 14,960 21,720 15,845 600 4.0 3.9 21,400 15,725 23,790 16,725 5.0 5.9 22,800 16,315 25,400 17,410 6.0 8.4 16,450 15,025 17,805 15,870 2.0 0.3 18,915 16,720 20,720 17,500 3.0 0.7 21,885 18,185 23,895 19,035 800 4.0 1.3 24,345 19,275 26,700 20,250 5.0 2.0 26,345 20,130 29,085 21,260 6.0 2.8 17,935 16,800 19,335 17,750 2.0 0.8 22,280 19,730 24,261 20,715 3.0 1.8 25,620 21,440 28,135 22,525 1000 4.0 3.1 28,350 22,680 31,350 23,345 5.0 4.7 30,650 23,660 34,015 25,050 6.0 6.7 21,500 19,760 23,240 21,035 2.0 0.5 26,200 23,380 28,220 24,545 3.0 1.1 20,335 25,830 32,915 27,030 1200 4.0 2.0 33,680 27,475 36,845 28,385 5.0 3.0 36,550 28,770 40,195 30,295 6.0 4.3 APD (In. WC) 0.10 0.16 0.19 0.22 Model Number "WCW" SERIES HOT WATER HEATING CAPACITY (2 PIPE SYSTEM) Hot Water Heat Capacity @ 65 F E.A.T. WPD Entering Water Temperature CFM GPM (Ft.Wtr) 140 F 160 F 170 F 180 F 33,053 39,880 44,170 48,465 2.0 1.1 36,930 44,590 49,370 54,150 3.0 2.2 39,055 47,180 52,220 57,265 4.0 3.9 40,364 48,780 53,980 59,185 5.0 5.9 41,254 49,870 55,180 60,490 6.0 8.4 39,488 47,550 52,720 57,900 2.0 0.3 45,946 55,370 61,360 67,370 3.0 0.7 49,738 59,980 66,450 72,930 4.0 1.3 52,187 62,970 69,740 76,520 5.0 2.0 53,878 65,040 72,015 79,000 6.0 2.8 42,059 50,625 56,140 61,670 2.0 0.8 49,813 59,990 66,510 73,040 3.0 1.8 54,601 65,800 72,925 80,060 4.0 3.1 57,806 69,705 77,225 84,760 5.0 4.7 60,091 72,490 80,295 88,110 6.0 6.7 49,534 59,773 61,200 72,630 2.0 0.5 60,319 72,775 80,605 88,445 3.0 1.1 67,119 81,000 89,700 98,415 4.0 2.0 71,692 86,545 95,830 105,120 5.0 3.0 74,884 90,490 100,180 109,800 6.0 4.3 Form: BSH0203/WCW-070106-8 APD (In. WC) 18WCW 600 0.10 24WCW 800 0.16 30WCW 1000 0.19 36WCW 1200 0.22

Model Number H02-46-26 H02-46-30 H02-46-37 H02-37-34 H02-37-39 H03-49-43 18/24WCW-HW 30WCW-HW 36WCW-HW DEDICATED VERTICAL/WALL MOUNT WCW-Chilled Water Cooling Electric or Hot Water Heating "H" AND"WCW" SERIES HOT WATER HEATING CAPACITY (SEPARATE HOT WATER COIL) Hot Water Heat Capacity @ 65 F E.A.T. WPD (Ft.Wtr) APD (In. WC) Entering Water Temperature CFM GPM 140 F 160 F 170 F 180 F 26,000 33,900 37,600 41,700 730 4.0 1.9 0.28 30,000 39,400 43,700 48,400 800 4.0 1.9 0.32 37,000 47,500 52,800 58,000 780 4.0 2.9 0.31 34,000 43,200 48,500 54,400 985 4.0 1.9 0.47 39,000 48,500 56,000 62,800 960 4.0 2.9 0.45 43,400 56,200 62,500 68,800 1125 4.0 4.8 0.47 30,000 39,400 43,700 48,400 800 4.0 1.9 0.32 39,000 48,500 56,000 62,800 960 4.0 2.9 0.45 43,400 56,200 62,500 68,800 1125 4.0 4.8 0.47 Operation of SunTherm Air Handler W/ Hot Water Heat Circulating pump and Air Handler blower are energized by conventional heating thermostat. Pump circulates hot water from hot water heater to heating coil in Air Handler and blower circulates warm air throught the duct system. When thermostat is satisified, pump and blower are de-energized. Equipment Sizing 1. Calculate heat loss of structure by ACCA or ASHRAE load calculation method. Air Handler heating capacity should be equal to, or exceed load calculation. 2. Select a water heater whose BTUH input/recovery effeciency exceeds heating capacity of Air Handler. The heating capacity of the Air Handler will not exceed the net output of the water heater. 3. Air Handlers are capable of using hot water from other sources such as boilers as long as hot water does not exceed 180 F. 4. Call a SunTherm Distributor for assistance in sizing. Form: BSH0203/WCW-070106-9

WCW-Chilled Water Cooling Electric or Hot Water Heating OPTIONAL "PICTURE FRAME" WALL PANEL DOOR 24.500 NYLON THUMB SCREWS 43.625 17.375 41.500 15.000 26.625 7.350 1.500 1.000 x.125 SLOT 4 PLS 1.000 7.250 0.219 DIA 8 PLS 0.250 DIA 4 PLS 43.625 39.625 22.625 7.250 4.000 26.625 CHANNEL SECTIONAL VIEW 1.00 0.625 1.00 4.000 Form: BSH0203/WCW-070106-10

ACCESSORIES AND OPTIONS FIELD INSTALLED ACCESSORIES AND FACTORY INSTALLED OPTIONS Thermal Expansion Valves (Factory or Field) All Units Downflow Conversion Kits (Multi-Position) TXV3-A Expansion valve 1.5-3.0 tons R-22 DFK41-10 Fits CA0XX820 coils TXV3-B Expansion valve 3.0-5.0 tons R-22 DFK41-12 Fits CA0XXA821,861 coils TXV4-A Expansion valve 1.5-3.0 tons R-410a DFK41-14 Fits CA0XXA822,862,892 coils TXV4-B Expansion valve 3.0-5.0 tons R-410a Specify Field or Factory Installed DFK15-16 DFK15-18 DFK15-20 Fits CA0XXA863 coils Fits CA0XXA864,894 coils Fits CA0XXA865,895,695 coils Hydronic Accessories All Units Accessories for Dedicated Vertical/Wall Mount 68AC002 Pump timer for hydronic coil pruge. WPD02 Wall panel door for 02 models RPA-01 Remote pump assembly 4 GPM 1/2" WPD03 Wall panel door for 03 models RPA-02 Remote pump assembly 4 GPM 3/4" LCD02 Louvered coil door for 02 models RPA-03 Remote pump assembly 7 GPM 3/4" LCD03 Louvered coil door for 03 models Deduct available to remove pump for boiler loop applications. BRP02 BRP03 WB Bottom return air panel for 02 model Bottom return air panel for 03 models Wall Mounting Brackets Field Installed Electric Heaters "S41" Multi-Position S41HK-03 3 KW without breaker B41HK-03 3 KW with breaker S41HK-05 5 KW without breaker B41HK-05 5 KW with breaker S41HK-06 6 KW without breaker B41HK-06 6 KW with breaker S41HK-08 8 KW without breaker B41HK-08 8 KW with breaker S41HK-10 10 KW without breaker B41HK-10 10 KW with breaker B41HK-12 12 KW with breaker Field Installed Electric Heaters "S15" Multi-Position 5 KW without breaker 5 KW with breaker S15HK-05 B15HK-05 S15HK-06 B15HK-06 S15HK-08 B15HK-08 S15HK-10 B15HK-10 B15HK-12 B15HK-15 B15HK-20 6 KW without breaker 6 KW with breaker 8 KW without breaker 8 KW with breaker 10 KW without breaker 10 KW with breaker 12 KW with breaker 15 KW with breaker 20 KW with breaker CPL1 CPNL1 CPL2 CPNL2 CPL3 CPNL3 CPL4 CPNL4 TDR Accessories For Furr Down Horizontal Louvered Access Panel (18,19,24) Non-louvered Access Panel (18,19,24) Louvered Access Panel (25,30,31) Non-louvered Access Panel (25,30,31) Louvered Access Panel (34,35) Non-louvered Access Panel (34,35) Louvered Access Panel (36,37) Non-louvered Access Panel (36,37) Time Delay Relay 3 Typical Thermostat Wiring C 1 AIR HANDLER W W2 G R Y 2 W G R TYPICAL THERMOSTAT LOW VOLTAGE WIRING C Form: BSH0203/WCW-070106-11