Alexander Rduch. Assessment of Physical Protection Systems for the Decommisioning Phase of German NPPs

Similar documents
Nuclear Security during the Decommissioning of NPPs

APPENDIX 4J SECURITY AND SURVEILLANCE SERVICES

Intrusion Detection Measures Against Insider Threats In Al-Tuwaitha Nuclear Site

Safety & Security Checklist by Layers of Building and Grounds The Church Safety and Security Guidebook (Brotherhood Mutual Insurance)

PHYSICAL PROTECTION SYSTEMS AND MEASURES FOR NUCLEAR MATERIAL AND NUCLEAR FACILITIES IN UGANDA

Comparative Study Between The IAEA Model Regulations and The Egyptian Nuclear Law

BEST PHYSICAL PROTECTION PRACTICES IN SPANISH NUCLEAR POWER PLANTS

Perimeter Security for Luxury Auto Dealerships

Ten Tips for Completing a Site Security Plan

Y. ORMIERES. Fire risk analysis method for nuclear installations

Safety Security Interface (SSI) at Bhabha Atomic Research Centre, Mumbai, India

DECOMMISSIONING OF THE REACTOR VESSEL OF THE COMPACT SODIUM COOLED NUCLEAR REACTOR FACILITY (KNK)

Workplace Violence Risk Factors and Controls Checklist

Workplace Violence Risk Factors and Controls Checklist

Arrangements for detection, interdiction and response to criminal or unauthorized acts involving nuclear and other radioactive materials

XYZ NURSING HOME EMERGENCY PREPAREDNESS PROGRAM INDEX

Life on the Edge: Securing the Perimeter with respect to CFATS (Chemical Facility Anti-Terrorism Standards)

UFF Position Statement: Community Risk Assessment/Threat Assessment Checklist

The Development of an Integrated Site System for the detection of illicit trafficking of radioactive and nuclear materials

New City Council Member Orientation

DAVIS POLICE DEPARTMENT

Domestic Nuclear Detection Office (DNDO)

U. S. Department of Energy Physical Protection Upgrades at the Latvian Academy of Sciences Nuclear Research Center, Latvia* Michael Haase

Presented By. BEI Security

FIRE PROTECTION ISSUES IN THE HOT CELLS OF A NUCLEAR FACILITY

Vacant Building Loss Prevention Best Practices

INTERNATIONAL SECURITY TRAINING, LLC PRESENTS THE PHYSICAL SECURITY SPECIALIST INTRO MODULE

The. Long Beach, California August 14-17, Solutions Network. Physical Security PERIMETER SECURITY TECHNOLOGIES. Leon Snyman GVI Security, Inc.

Minor Change Office of Radiological Safety Number: Revision 00 By: Georgia Institute of Technology. Approved 04/21/2016 Date: / / Page 1 of 6

Marine Insurance Day 2011

EP ISSUES FOR INDEPENDENT SPENT FUEL STORAGE AND DECOMMISSIONING FACILITIES. Scenario Development For Shutdown And Defueled Nuclear Power Stations

Virtual Boundary System Using Passive Infrared Sensor

COMMERCIAL BUILDING SOLUTION

DRAFT REGULATORY GUIDE DG-1069 FIRE PROTECTION PROGRAM FOR NUCLEAR POWER PLANTS DURING DECOMMISSIONING AND PERMANENT SHUTDOWN

Security & Monitoring Services

Perimeter protection for airports with intelligent video surveillance

Professional Security Officer Program(PSOP)

Physical and Environmental Security. CISSP Guide to Security Essentials Chapter 8

Transaction Windows and Security Entrances

Development of Post-Accident Monitoring System for Severe Accidents

G-MAX IVS R123 Vibration Sensors Perimeter Intrusion Detection System

Fire Protection Approaches and Experiences in NPP

This copy courtesy ARS/MPI. This document is from a CD-ROM distributed courtesy of Appendix R Solutions. and Matrix Press, Inc. You may not alter,

Why Should You Invest In An Access Management System?

For Complete Security

Crime Central Station Burglary Alarm Systems

Annex 2 - Shelter-in-Place

Andrew Blair CCG(Scotland)Ltd

342 Perimeter Security SECURITY SURVEY FORMS

KASC Community Safety Awareness Meeting November 16, 2010 Eastman Lodge

Fire Protection Regulatory Approach for Nuclear Power Plants in Canada

NCRP REPORT No. 165National Council RESPONDING TO A RADIOLOGICAL OR NUCLEAR TERRORISM INCIDENT: A GUIDE FOR DECISION MAKERS

GOOD PRACTICES ON NUCLEAR SECURITY CULTURE

Warrington Road Nursery School

Security Considerations for Secure Workplaces

Considerations on the 3S with focus on security-safeguards interfaces

- Basic information of Laser Scan detector

INTRUSION SOLUTIONS. Yehans Surveillance & Security Systems. laser perimeter alarming CONTACT US ON

Integration of safety and security for effective control and protection of radioactive sources

Emergency Codes Overview

Building Integration System. Your platform for customized security and safety management.

Apartment building safety audit assessment

A.C.E. Security Consultants House of Worship Checklist

TABLE OF CONTENTS. Medical & First Aid Procedure 11, 12. Hazardous Material Emergency Response 17. Civil Disturbances and Demonstrations 21

STANDARD OPERATING PROCEDURE

Chapter 7: ADDITIONAL STUDIES

Nuclear or Radiological Emergencies & Management of Radiological Accidents RADKOR 2017

Protection against Internal Hazards in the Design of Nuclear Power Plants

Site Security Plan - Operations Baron Winds Project

Protection against Internal Hazards in the Design of Nuclear Power Plants

4.13 Security and System Safety

Preliminary Site Security Plan Operations Cassadaga Wind Farm

Access Controls for High Radiation Areas NISP-RP-05

Protecting Station Platform & Rail Perimeters. TransitVUE IDS The Latest in Fiber Optic Station Platform & Rail Perimeter Security Sensor Systems

Border Security: Preventative Rad/Nuc Detection PRND

Regulatory Perspective for Fire Protection and Emergency Management at Nuclear Facilities in Canada

EMC Company Background. Top 10 List (cont.) Top 10 List. Locked Door Policy. 1. Lack of a Security Culture

Safety and Security in industrial applications of radioactive sources. Two principles, one only commitment. Walter Adrian Truppa

designing for School Safety and Security

Nuclear Energy Perimeter Security. Application Note

What is an Emergency?

NGUYEN NU HOAI VI Vietnam Agency for Radiation and Nulcear Safety

ZKBioSecurity Manufacturing Security System

CBSA s Radiation Detection Program (RADNET)

Effective Deployment of the Integrated Wireless Network Video Systems for the Homeland Security & Government Sectors

PERIMETER DEFENCE. Panorama Intruder Detection System Long Range, Day & Night, Automatic Panorama Intruder Detection

The Safety and Security of Radioactive Sources: past, present and future. Steve McIntosh

Improving the Security of Radioactive Sources in Industrial Radiography in South East Asia

Your computer system is the lifeblood of your business. Cyber threats are. what you hear most about today. Hacks, viruses and spyware get constant

ADVANCED MONITORING AND SECURITY SYSTEMS FROM BOSCH SECURITY SYSTEMS

SECURITY SOLUTIONS Banking and finance

HIGH SECURITY VAULT DOORS. A complete line of high security attack-resistant vault doors and accessories. AN ISO 9001 CERTIFIED COMPANY

Industrial Security Capabilities. Honeywell Proprietary

The ODP/OLES 5-Year Plan for CBRNE Standards

IIPP. Injury & Illness Prevention Program Hartog Drive San Jose CA Responsibilities. Workplace Hazards. Training. Incident Investigations

NJ Office of Homeland Security and Preparedness Facility Self-Assistance

The Fiber SenSys Perimeter Intrusion Detection System From JM Fiber Optics!

University Center of Lake County. Emergency Preparedness Guide

TetraTek, Inc. Regulatory. Compliance. Emergency Response. Nuclear Facility Compliance. Compliance. Fire Protection.

CCTV Camera Systems and Project Engineering

Transcription:

Alexander Rduch Assessment of Physical Protection Systems for the Decommisioning Phase of German NPPs

Germany s decision to phase out Consensus to phase out since 2000 Lifetime extension of German NPPs 2010 Fukushima March 2011

German NPPs in operation Brokdorf KBR Emsland KKE (*) Grohnde KWG Gundremmingen KRB B KRB C Isar KKI 2 (*) Neckarwestheim GKN 2 (*) Philippsburg KKP 2 (*) in operation until 31.12.2022 (AtG)

German NPPs non operational Biblis KWB A KWB B Brunsbüttel KKB Grafenrheinfeld KKG Isar KKI 1 Krümmel KKK Neckarwestheim GKN 1 Philippsburg KKP 2 Unterweser KKU non-operational since 06.08.2011 KKG since 27.06.2015

Decommissioning guideline 2016 reduced risk potential with or without nuclear fuel elements nuclear facilites nearby until removal of nuclear fule elements: heat release from fuel pool coolant loss from fuel pool handling and storage of nuclear fuel elements description of nuclear security measures (security report)

Decommissioning of NPPS phases operation power operation post operation phase residual operation decommissioning shutdown safe enclosure dismantling with nuclear fuel elements without nuclear fuel elements decontamination removal of other radioactive material

Remaining risk potential during the decommissiong nuclear fuel elements fresh fuel spent fuel other radioactive material remaining threats sabotage theft

Possible procedures DBT for all phases DBT for nuclear fuel elements DBT for other radioactive material different risk potential for sabotage and theft Graded security concept large amount of nuclear fuel small amount of nuclear fuel without nuclear fuel completing decontamination, other radioactive material

Graded Approach using the 19 Security Functions from Deterministic Security Analysis (DSA)

no modification Security function nr. 1 Obstruction of an intrusion of a violent group of people into the NPP area Interference of violent protesters Massive fence ( steel or concrete, 2.5 m height) Paved road for respond forces inside the fence

no modification Security function nr. 2 Prevention of violent intrusion into outer protected area using a heavy duty vehicle Unauthorizes entry into the NPP area (car bomb, further potential equipment) Tested vehicle barrier around the area against intrusion of a heavy duty vehicle with selected weight

no modification Security function nr. 3 Surveillance of the area in front of the outer boundary, detection of adversary preparations Preparation of an attack (e.g. to get into the protected area) Open area in front of the outer boundary Lighting Roving patrols (Security Guard Service)

system-dependent consideration Security function nr. 4 Prevention of the triggering of situations that can not be handled by the safety systems, prevention of other major radiological release resulting from interference from outside the protected areas Disturbance of the cooling water supply (explosives) Subaqueus blast waves against the intake pipe for cooling water Protected cooling water supply within the protected area Measures to decrease pressure from blast waves within the cooling water channels

no modification Security function nr. 5 Reliable detection, identification and localization of intruders along the outer boundary Intrusion without alarm Fence system with technical detection, camera surveillance and lighting Patrolling security guards

no modification Security function nr. 6 Adequate conditions for the security guard service and the response forces within the outer protected area and along the boundary of the inner protected area Adversary entered the outer protected area Clear arrangement of the buildings Avoid hiding options within the NPP area Alarm lighting system

system-dependent consideration Security function nr. 7 Delay of the intrusion of adversaries into the inner protected area until the end of the responds time Violent intrusion attempt into safety relevant buildings to trigger a nuclear melt down Barriers around safety relevant buildings that resist attacks (according the potential weapons in the DBT) for a definite minimum of time

no modification but possible with analysis and verification Security function nr. 8 Reliable and complete overview of the security status from a central and protected place, activation and controlling of security systems, communication with responds forces Violent interference Central alarm station within a protected building, Minimum of two persons in the central alarm station

no modification but possible with analysis and verification Security function nr. 9 Secured possibility to open the access to the inner protected area from outside Break down of the central alarm station Protected set of keys outside the central alarm station

system-dependent consideration Security function nr. 10 A qualified, reasonable equipped Security Guard Service in addition to structural and other technical security features minimum education for security guards, trustworthiness determination, frequent further courses

no modification Security function nr. 11 Protection of the security guards at the main entrance against violent attacks Violent attacks against security guards in the guard building, gunfire from outside Bullet proved and intrusion delayed construction of the part of the building, where the guards work,

no modification Security function nr. 12 Control, identification, documentation and allowance of the entry of persons, goods and vehicles according the authorization at the gates of the outer boundary (protected area), possibility of blockage and prevent the entry of unauthorized goods Entry of unauthorized persons or vehicles and materials (weapons, explosives) Entry control and contraband detection of persons and materials through manual search, x ray inspection and detection (metal, radiation, explosives)

no modification but possible with analysis and verification Security function nr. 13 Control, identification, documentation and allowance of the entry of persons to the inner area according to the authorization, possibility of blockage and prevention of the entry of unauthorized goods Unauthorized entry of persons to the inner protected area and entry of contraband to an inner protected area Entry control and contraband detection

no modification Security function nr. 14 Prevent and detect theft of nuclear material (quantity and type) Violent theft of nuclear material Storage of unirradiated nuclear material within the barriers of protected buildings (inner protected area)

no modification but possible with analysis and verification Security function nr. 15 Prevent, obstract and detect interferences of an insider that could Trigger incidents beyond the design basis or influence the handling of incidents within the safety design basis (sabotage) Through collaboration, facilitate the entrance of adversary from outside into the inner protected area or prevent from alarming the responds force Insider triggers a nuclear melt down Measures to prevent that a single insider is able to trigger an incident and also manipulate necessary safety systems

no modification Security function nr. 16 Recognition of hostage and extortion at the outer boundary, delay of further action to be carried out Facilitate entrance to inner protected area by hostage and extortion Emergency Alarms Arrangement of code words to reveal a hostage situation

no modification Security function nr. 17 Preserving of a sufficient level of security also if security systems are jammed or broken (planned substitute measures) Failure in the Physical Protection System because of broken Security Systems Strategy for breakdown cases Storage of a sufficient number of spare parts

no modification Security function nr. 18 Employment of trustworthy personnel Potential vulnerability of the plant because of the employment of untrustworthy or criminal personnel Federal trustworthiness determination of the personnel in nuclear facilities

no modification Security function nr. 19 To have technical and organizational infrastructure available to support the impact of the response forces Violent interference Available onsite headquarter within the facility with all needed equipment (e.g. communication) Heliport at the facility Joined training of response forces and security guards

Specifics Phase with nuclear fuel elements Separation of buildings with consideration of Inner Area Additional security measures for interfaces Protected Area needed without any changes Optional relocation of Central Alarm Station Phase without nuclear fuel elements Adjustment of security concept Reduction in defence in depth concept Change in access control procedures Additional locks for material and vehicles Detection of barriers with technical means or with personnel

Be prepared decommissioning is coming for each and every NPP there is no best way Development of an unified standard for evalutation and assessment is needed even for different approaches and procedures