Installation Manual. Expansion Module 0100 Version 1.0 EXP HBX Control Systems Inc.

Similar documents
Installation Manual. THM-0100 Setpoint Thermostat Version THM HBX Control Systems Inc.

Viessmann B1HA Boiler Series

Low Temperature Stainless Steel Panel Series Installation and Commissioning Guide

Installation Manual ZON-0500 Version 2.30 ZON HBX Control Systems Inc.

CPU HBX Control Systems Inc. Installation Manual Central Processing Unit 0550 Version 1.04

Installation Manual. THM-0200 Programmable Thermostat Version 1.07 THM HBX Control Systems Inc.

P r o d u c t C a t a l o g u e

Installation Manual Central Processing Unit 0550 Version 2.00 ECO HBX Control Systems Inc.

Dual Mixing Application

Sentry LIQUID LEVEL CONTROLLER MODEL 120 OPERATING MANUAL.

INSTRUCTION MANUAL P Heating and 1 Cooling

Geothermal Programming Guide. Central Processing Unit 1000 Version 1.33 ECO HBX Control Systems Inc. Page 1

INSTRUCTION MANUAL TS21. 2 Heating and 1 Cooling

Installation Manual NPE-180A/240A WARNING. Add-on Controller Installation Kit

VX SERIES Wireless Thermostat with Occupancy Sensor

Installation Manual WARNING. Add-on Controller Installation Kit NPE-180A/210A/240A

SYSTEM CONTROL KIT Model: CK-41P

2-Port alarmcharge Hub - Manual

Instruction Manual US PAT: 6,824,069 6,786,421. Models: CT03TS21 CTO3TS32 CTO3TS32H

Sentry LIQUID LEVEL ALARM MODEL 100 OPERATING MANUAL.

5+2 DAY. OWNER S MANUAL Venstar Inc. 05/08

Installation Manual WAV-0110 WAV-0111 WAV Version WAV-0110 WAV-0111 WAV HBX Control Systems Inc. Page 1

VENSTAR T1070 FAN COIL THERMOSTAT PROGRAMMABLE 2 OR 4 PIPE SYSTEMS OWNER S MANUAL AND INSTALLATION INSTRUCTIONS

READ THESE INSTRUCTIONS CAREFULLY AND COMPLETELY BEFORE PROCEEDING WITH THE INSTALLATION.

Carrier NON-PROGRAMMABLE DIGITAL THERMOSTAT. Dual Setpoint Thermoglow Backlight No Batteries Required Auto Changeover Locking Keypad

Non-Programmable Digital Thermostat

MaxLite LED Vapor Tight Linear Fixture

INSTRUCTION MANUAL HS-229G

5+2 DAY. Digital Thermostat. residential. & 1-cool. up to 2-heat PROGRAMMABLE THERMOSTAT. Venstar Inc. 05/08

Sentry LIQUID LEVEL GAUGE MODEL 200 or 200C OWNER MANUAL REV 1.7 SEPT08 PAGE 1 OF 12

SYSTEM CONTROL KIT READ THESE INSTRUCTIONS CAREFULLY AND COMPLETELY BEFORE PROCEEDING WITH THE INSTALLATION.

OWNER'S MANUAL T0140. Contents Page #

Ion Genesis II Pump Controller Digital Level Control with Pump Alternation and High Water Alarm

ion Genesis Pump Controller

VENSTAR T1075 FAN COIL THERMOSTAT 7 DAY PROGRAMMABLE 2 OR 4 PIPE SYSTEMS OWNER S MANUAL AND INSTALLATION INSTRUCTIONS

24 VAC SYSTEM CONTROL KIT Model: CK-91F and CK-91FG

10810 W. LITTLE YORK RD., STE. 130 HOUSTON TX VOICE (713) FAX (713) web: IMPORTANT!!!

Humidity Module OWNER S MANUAL. Complete Control from

Users Manual. LAURUS Systems, Inc. - Ph: Fax:

Installation, Operation & Service Manual

Ion Endeavor Pump Controller Digital Level Control with Pump Alternation and High Water Alarm

INSTRUCTION MANUAL P Heating and 2 Cooling with Humidification and De-humdification

120 VAC SYSTEM CONTROL KIT Model: CK-63

120 VAC SYSTEM CONTROL KIT

INSTALLATION INSTRUCTIONS and OPERATING MANUAL. *Aquastat is a registered trademark of Honeywell International, Inc.

be liable for any other loss or damage, whether direct, indirect, incidental or consequential.

Owner s Manual. Digital. Heat Pump. 5+2 Day Programmable. Model S1-THEH21P5S HVAC SERVICE PARTS TM

TMC. Installation and Operation Manual TMC. Temperature and Pressure Monitoring for Heating and Cooling Applications. Temperature Monitoring Control

5+2 Day. up to HEAT COOL

LiqTec, V GRUNDFOS INSTRUCTIONS

Owner s Manual. PIR-1 IR Learner

IMPORTANT SAFETY INFORMATION:

MODEL TSTATBBPB101 PROGRAMMABLE DIGITAL THERMOSTAT. Heat Pump & Heat Cool. Meets California Title 24 Residential USERS INFORMATION MANUAL

Installation and Operations Manual

Owner s Manual. Digital Thermostat. Heat/Cool & Heat Pump 7-Day Programmable S1-THEM22P7S COMMERCIAL. Model HVAC SERVICE PARTS

Fan Speed. Auto Swing. Timer. Power. Mode. Fan. Only. Saver. Temp. Dry. Fan. Speed. Auto Swing. Timer. Power. Mode. Saver. Only. Temp.

Original instructions Sense7-series Non-contact coded safety switch

Operations Manual. Motion Detector Module Model ZS10

Owner s Manual. 5+2 Day Programmable Digital Thermostat

TrueClean ToteCleaner

7-Day. Digital Thermostat. residential. & 2-cool

BioZone Scientific International contact information

Series: MBC1-TC Mini Benchtop Temperature Controller

FloorHeat Installation Manual

Thermostat Remote Control & Receiver

Installation Instructions

PRACTICAL USER S GUIDE FOR THE ELECTRIC STOVE

INSTALLATION & OPERATION MANUAL

TrueClean ToteCleaner

AG Series Electric Heaters

PLL Pump-Lead-Lag. Provides Pump Rotation, Auxiliary Pump Activation, and Pump Failure Alarm Control. Installation and Operation Manual

Quest Power Electric Heat EHS 62 Pro

Model 20201/20201-A/20201-B Wind Sensor Heater. User's Manual. All Weather Inc National Drive Sacramento, CA USA

WIRING DIAGRAMS R410A MODELS PAC 2OAC/2OACH CAC OWC PWC

PROFESSIONAL CURLING IRON with adjustable temperature settings and Auto Shut Off after 60 minutes

COMBUSTION AIR SYSTEM Model: CAS-3

Owner s Manual Use with most Heat Pump systems: 1-Heat, 1-Cool 2-Heat, 1-Cool

EQUIPMENT Operation Manual

IMPORTANT SAFETY INFORMATION:

INSTALLATION AND OPERATING INSTRUCTIONS FOR THE VEHICLE-MOUNTED RADIATION DETECTION SYSTEM

BX Series. Installation, Operation, Maintenance Instructions & Spare Parts

Design Criteria. Installation

Learning Thermostat Installation Guide. Installation step by step

Powerley Thermostat. Installation & Operation Guide

INSTALLATION INSTRUCTIONS and OPERATING MANUAL. *Aquastat is a registered trademark of Honeywell International, Inc.

1 For All Programmable or Non-Programmable. Digital Thermostat. Meets Residential California Title 24

OWNER S MANUAL PLEASE READ AND SAVE THESE INSTRUCTIONS WHOLE ROOM RADIATOR HEATER. Model: HO-0221 THERMOSTAT

CO2 Sensor User and Installation Guide

Features & Benefits. Description. Example of LCD display screen. Functionality. Ordering Information: Model 7600 Boiler Control

OPERATING MANUAL/ INSTALLATION

Models LBW-420-LEL (24 VDC powered) Ammonia Leak Detector

GG-EM ENTRANCE MONITOR. Installation and Operation Manual

Patent Pending invent for New Construction

CD6102 / CD6102 OC / CD6102-2

Blade Series Heat Exchanger Operation and Installation

ELECTRIC FIREPLACE HEATER WITH SINGLE GLASS DOOR

[Thermo Simple 2 (TS.2)] Thermo Simple 2 Manual. Refrigeration Innovation

Installation and Owner Man u al

Instruction Sheet LTR - Low Water Cutoff for Hot Water Boilers

Multiple Boilers Electro TS Series Application EB-C-STG5

Transcription:

Installation Manual 000 Version.0 EXP-000 HBX Control s Inc.

Control s Inc. HBX EXP 000 Version.0 HBX EXP-000 EXPANSION MODULE INTRODUCTION The EXP-000 is designed to be integrated with the HBX CPU-000 HVAC Controller, it is not a stand alone control device. The purpose and function of the EXP-000 is to provide system expansion capabilities. Its primary use is to add additional boiler stages. For example, CPU-000 + EXP-000 can provide a total of 4 boiler stages (when configured as a staging control). If the Control is configured as a mixing control and more than one boiler is required, the program within the CPU-000 anticipates (defaults) that boiler stages are connected through the s (refer to drawing MIX 000-05 of this manual). The EXP-000 has a spare thermistor input with no fixed function. The installer may choose to run the spare thermistor as a; room sensor, setpoint sensor, or a return water temp sensor. The spare demand signal has no dedicated function at the time of print. The position of setpoint sensors (thermistors) are critical to the correct operation of the Control. Pay special attention to the wiring of setpoint sensors in relation to actuators, pumps, and multiple boiler stage relays. Example shown in Application Drawing MIX 000-04. HBX has developed a series of s. At time of product introduction the EXP-000 (Staging) and EXP-0300 () Modules are made available. These will be followed by the release of the ZON-0500 (Zone Control), and the MOD-000 (Modulating Output Module) Module. A combination of these Modules are designed to tackle a variety of applications, using a maximum of *six Modules in unison with a single CPU-000 Control Unit. The sequence in which the Modules are connected is very important. Install the Modules that you are utilizing in the following order: CPU-000, Staging Controls, Controls, Modulating Controls, Zone Controls. * More than six Zone Modules can be connected to the CPU- 000 as the Zone Modules are not dependent on the CPU to power the relays. The EXP-000 is designed to be wall mounted, DIN rail mounted, or installed inside a separate electrical enclosure. The unit should be mounted inside and be protected from falling water and high humidity conditions. With all the covers in place it is designed to protect any individual from accidental electrical shock. EXP-000 Manual Page

Control s Inc. HBX EXP 000 Version.0 INSTALLATION PROCEDURE Place the CPU-000 and desired s on a flat surface. Align the 3-Pin connector into the holes on the and gently push into place. Next slide the CPU-000 onto the 3-Pin connection by carefully matching up the holes and pins. When installed correctly there is virtually no gap between units. With power applied to the assembly, the first (green) LED should be illuminated on each. This lit, green LED serves as confirmation of both electrical and communications continuity. 3- Pin Connector P/N 033-0037 TERMINAL DESIGNATIONS Extra Thermistor Extra Relay Extra Demand Signal Extra Relay Extra Thermistor - Gives you many choices. E.g. Room sensor or setpoint sensor. Extra Demand Signal - Any heat demand signal powered by 0-40VAC. E.g. 4VAC thermostat (future applications). Thermistor inputs are designed for 0K Ohm thermistors and must never be subjected to any external power supply (voltage or current). Extra Relay - This relay is the default relay for bringing on multiple boiler stages. E.g (stage) 4, 6, 8 etc. depending on the number of Modules connected together. Extra Relay - This relay is the default relay for bringing on multiple boiler stages. E.g (stage) 3, 5, 7, etc. depending on the number of Modules connected together. Extra Relays & are dry contacts and rated for a max of 0Amps. HBX Control s Inc. 0 EXP-000 Manual Page

Control s Inc. MAIN PARTS AND LABELS. 3 Pin Connector Port. Power and Communications LED 3. Relay LED 4. Relay LED 5. Aux. Relays / Extra Stages 6. Input Signal A 7. Thermistor HBX EXP 000 Version.0 Specifications: x Thermistor Input (0K Ohm) x Misc. Input Signal (0-40VAC) x Aux. Output Relays (40VAC 0Amps) Weight: 0.408Kg Dimensions: 00mm W x 70mm H x 70mm D ETL Listings: Meets CSA C. No. 4 Meets UL Standard 873 ETL Control No. 306843 Storage: 0ºC to 40ºC PHYSICAL DIMENSIONS Side View 70mm Front View 7 66mm Rear View Top View 68mm Bottom View 63.mm 00mm 86mm EXP-000 Manual Page 3

Input: 0VAC 60Hz 5A Relays: 40VAC 0A Demand Signal: 0-40V Central Processing Unit Model: CPU - 000 CAUTION, RISK OF ELECTRICAL SHOCK - DIS PRIOR TO SERVICING B C D Certified to CSA C. No 4 Conforms to UL Standard 873 Input: 0VAC 60Hz 5A Demand Signal: 0-40V Relays: 40VAC 0A Model: EXP-000 CAUTION, RISK OF ELECTRICAL SHOCK - Certified to CSA C. No 4 DIS PRIOR TO SERVICING Conforms to UL Standard 873 Control s Inc. HBX EXP 000 Version.0 STAGING CONTROL STG 000-04 4 stage boiler control One system pump piped reverse return ELECTRICAL DS DS CPU-000 0-40 v 0-40 v 0-40 v 0 A 0 A CENTRAL PROCESSING UNIT 0 A 0 A 0 A 9 0 9 0 0 0 0 0 3 3 3 3 L N GR L N GR L N GR L N GR EXP-000 EXPANSION MODULE 0-40 v 0 A 0 A Apply Control Signal or Program for Permanent Heat Demand Outdoor 4VAC TH Stage Stage Hi Temp 3 4 Stage 3 Stage 4 C R 0VAC L N MECHANICAL Control Type: Staging Utilized 000 EXP-000 Legend: P - Hi-Temp 000 00 0VAC Heat P Hi Temp Load HBX Control s Inc. 0 EXP-000 Manual Page 4

Input: 0VAC 60Hz 5A Relays: 40VAC 0A Demand Signal: 0-40V Central Processing Unit Model: CPU - 000 CAUTION, RISK OF ELECTRICAL SHOCK - DIS PRIOR TO SERVICING B C D Certified to CSA C. No 4 Conforms to UL Standard 873 Input: 0VAC 60Hz 5A Demand Signal: 0-40V Relays: 40VAC 0A Model: EXP-000 CAUTION, RISK OF ELECTRICAL SHOCK - Certified to CSA C. No 4 DIS PRIOR TO SERVICING Conforms to UL Standard 873 Control s Inc. HBX EXP 000 Version.0 STAGING CONTROL STG 000-09 x Hi/Lo boiler ( stage) with main hi-temp system pump pump is being controlled directly from the internal boiler (staging) contacts Outdoor reset of boiler target temp is controlled via the outdoor sensor and the boiler sensor on the supply pipe An additional setpoint load in the form of a fan coil, fan coil high-speed controlled at the same time as fan coil actuator ELECTRICAL CPU-000 CENTRAL PROCESSING UNIT EXP-000 EXPANSION MODULE 0-40 v 0-40 v 0-40 v 0 A 0 A 0 A 0 A 0 A 0-40 v 0 A 0 A DS DS 7 8 9 0 9 0 0 0 0 0 3 3 3 3 L N GR L N GR L N GR L N GR Primary Heat Load Actuator V R W Fan Coil Hi Speed Motor Enable Primary Heat Load Thermostat TH Outdoor Setpoint V Fan Coil Actuator 4VAC C R Stage Stage P 0VAC L N MECHANICAL Control Type: Staging Utilized Outdoor EXP-000 Legend: P - P - 0VAC 000 000 00 NB. Design Heat Load must be a High Temp Radiant Eg. Baseboard/Panel Radiators Heat P P Stage Room (Setpoint) TH Fan Coil Load Balancing Valve EXP-000 Manual Page 5

Input: 0VAC 60Hz 5A Relays: 40VAC 0A Demand Signal: 0-40V Central Processing Unit Model: CPU - 000 CAUTION, RISK OF ELECTRICAL SHOCK - DIS PRIOR TO SERVICING B C D Certified to CSA C. No 4 Conforms to UL Standard 873 Input: 0VAC 60Hz 5A Demand Signal: 0-40V Relays: 40VAC 0A Model: EXP-000 CAUTION, RISK OF ELECTRICAL SHOCK - Certified to CSA C. No 4 DIS PRIOR TO SERVICING Conforms to UL Standard 873 Input: 0VAC 60Hz 5A Demand Signal: 0-40V Relays: 40VAC 0A Model: EXP-000 CAUTION, RISK OF ELECTRICAL SHOCK - Certified to CSA C. No 4 DIS PRIOR TO SERVICING Conforms to UL Standard 873 Input: 0VAC 60Hz 5A Demand Signal: 0-40V Relays: 40VAC 0A Model: EXP-000 CAUTION, RISK OF ELECTRICAL SHOCK - Certified to CSA C. No 4 DIS PRIOR TO SERVICING Conforms to UL Standard 873 Control s Inc. HBX EXP 000 Version.0 STAGING CONTROL STG 000-0 4x Hi/Lo fire boilers (8 stages) with x hi-temp system pumps controlled on a pump sequencer pumps are being controlled directly from the internal boiler (staging) contacts Outdoor reset of boiler target temp is controlled via the outdoor sensor and the boiler sensor on the supply pipe Optional DHW shown using DHW pump on DHW priority ELECTRICAL CPU-000 CENTRAL PROCESSING UNIT EXP-000 EXP. MODULE EXP-000 EXP. MODULE EXP-000 EXP. MODULE 0-40 v 0-40 v 0-40 v 0 A 0 A 0 A 0 A 0 A 0-40 v 0 A 0 A 0-40 v 0 A 0 A 0-40 v 0 A 0 A DS DS 7 8 9 0 9 0 0 0 0 0 3 3 3 3 L N GR L N GR L N GR L N GR TH Outdoor Apply Control Signal or Program for Permanent Heat Demand Stage Stage P/P Hi Temp Sequencing Stage 3 Stage 4 3 Stage 5 3 Stage 6 4 Stage 7 4 Stage 8 4VAC C R P3 DHW 0VAC L N MECHANICAL Control Type: Staging Utilized 000 EXP-000 EXP-000 EXP-000 0VAC Legend: P + P - High Temp s setup to sequence every 48 hours P3 - DHW P4-P7 - s Heat P and P Sequencing 000 00 00 00 P4 P5 P6 P7 Load Stage Stage Stage Stage P3 DHW DHW HBX Control s Inc. 0 EXP-000 Manual Page 6

V Input: 0VAC 60Hz 5A Relays: 40VAC 0A Demand Signal: 0-40V Central Processing Unit Model: CPU - 000 CAUTION, RISK OF ELECTRICAL SHOCK - DIS PRIOR TO SERVICING B C D Certified to CSA C. No 4 Conforms to UL Standard 873 Input: 0VAC 60Hz 5A Demand Signal: 0-40V Relays: 40VAC 0A Model: EXP-000 CAUTION, RISK OF ELECTRICAL SHOCK - Certified to CSA C. No 4 DIS PRIOR TO SERVICING Conforms to UL Standard 873 Control s Inc. HBX EXP 000 Version.0 MIXING CONTROL MIX000-04 stage boiler, controlling boiler pump and mixed system pump Radiant injection valve using PMIv, maintaining a setpoint, Eg. ramp heating Outdoor reset of boiler target temp is controlled via the outdoor sensor and the boiler sensor on the supply pipe ELECTRICAL CPU-000 CENTRAL PROCESSING UNIT EXP-000 EXPANSION MODULE 0-40 v 0-40 v 0-40 v 0 A 0 A 0 A 0 A 0 A 0-40 v 0 A 0 A 9 0 9 0 0 0 0 0 3 3 3 3 L N GR L N GR L N GR L N GR Outdoor Setpoint 4VAC C R PMIv Injection Valve P P Stage Stage 0VAC L N MECHANICAL Control Type: Mixing Utilized Legend: P - P - 000 EXP-000 000 00 0VAC P Setpoint Balancing Valve Injection Valve P Ramp Heating EXP-000 Manual Page 7

V Input: 0VAC 60Hz 5A Relays: 40VAC 0A Demand Signal: 0-40V Central Processing Unit Model: CPU - 000 CAUTION, RISK OF ELECTRICAL SHOCK - DIS PRIOR TO SERVICING B C D Certified to CSA C. No 4 Conforms to UL Standard 873 Input: 0VAC 60Hz 5A Demand Signal: 0-40V Relays: 40VAC 0A Model: EXP-000 CAUTION, RISK OF ELECTRICAL SHOCK - Certified to CSA C. No 4 DIS PRIOR TO SERVICING Conforms to UL Standard 873 Control s Inc. HBX EXP 000 Version.0 MIXING CONTROL MIX 000-05 Mixing systems using more than boiler stage must be connected via or more EXP-000 units, note boiler contact terminations. Setup shows primary/secondary mixing via PMIp (injection pump), plus optional DHW control using an actuator valve (terminals 5 and 6) Outdoor reset of boiler target is controlled via the outdoor sensor and boiler sensor with DHW priority ELECTRICAL CPU-000 CENTRAL PROCESSING UNIT EXP-000 EXPANSION MODULE 0-40 v 0-40 v 0-40 v 0 A 0 A 0 A 0 A 0 A 0-40 v 0 A 0 A 9 0 9 0 0 0 0 0 3 3 3 3 L N GR L N GR L N GR L N GR TH 4VAC Apply Control Signal or Program for Permanent Heat Demand Outdoor A DHW Actuator Valve C R P P P3 PMIp Injection Micing Stage Stage 0VAC L N MECHANICAL Control Type: Mixing Utilized 000 EXP-000 Legend: P - P - Mixed P3 - Injection, PMIp P4-P5 - s Heat Load 0VAC 000 00 P P Mixed P3 PMIp Injection Balancing Valve P4 P5 A Balancing Valve HBX Control s Inc. 0 EXP-000 Manual Page 8

Input: 0VAC 60Hz 5A Relays: 40VAC 0A Demand Signal: 0-40V Central Processing Unit Model: CPU - 000 CAUTION, RISK OF ELECTRICAL SHOCK - DIS PRIOR TO SERVICING B C D Certified to CSA C. No 4 Conforms to UL Standard 873 Input: 0VAC 60Hz 5A Demand Signal: 0-40V Relays: 40VAC 0A Model: EXP-000 CAUTION, RISK OF ELECTRICAL SHOCK - Certified to CSA C. No 4 DIS PRIOR TO SERVICING Conforms to UL Standard 873 Control s Inc. HBX EXP 000 Version.0 MIXING CONTROL MIX 000-06 Single stage boiler, controlling boiler pump and mixed system pump Radiant injection pump using PMIp, maintaining a setpoint, Eg. ramp heating Outdoor reset of boiler target temp is controlled via the outdoor sensor and the boiler sensor on the supply pipe ELECTRICAL CPU-000 CENTRAL PROCESSING UNIT EXP-000 EXPANSION MODULE 0-40 v 0-40 v 0-40 v 0 A 0 A 0 A 0 A 0 A 0-40 v 0 A 0 A 9 0 9 0 0 0 0 0 3 3 3 3 L N GR L N GR L N GR L N GR Outdoor Setpoint P P P3 PMIp Injection 0VAC L G MECHANICAL Control Type: Mixing Utilized EXP-000 000 Legend: P - P - P3 - Injection 000 00 0VAC Setpoint P P3 Injection P Ramp Heating Balancing Valve EXP-000 Manual Page 9

Input: 0VAC 60Hz 5A Relays: 40VAC 0A Demand Signal: 0-40V Central Processing Unit Model: CPU - 000 CAUTION, RISK OF ELECTRICAL SHOCK - DIS PRIOR TO SERVICING B C D Certified to CSA C. No 4 Conforms to UL Standard 873 Input: 0VAC 60Hz 5A Demand Signal: 0-40V Relays: 40VAC 0A Model: EXP-000 CAUTION, RISK OF ELECTRICAL SHOCK - Certified to CSA C. No 4 DIS PRIOR TO SERVICING Conforms to UL Standard 873 Control s Inc. HBX EXP 000 Version.0 DOMESTIC HOT WATER CONTROL DHW 000-0 DHW Control / 4 stage boiler control pumps controlled by boiler DHW circulating pump, using x EXP-000 Single stage boilers ELECTRICAL CPU-000 CENTRAL PROCESSING UNIT EXP-000 EXPANSION MODULE 0-40 v 0-40 v 0-40 v 0 A 0 A 0 A 0 A 0 A 0-40 v 0 A 0 A 9 0 9 0 0 0 0 0 3 3 3 3 L N GR L N GR L N GR L N GR 3 4 DHW P DHW Circ. 0VAC L N MECHANICAL Control Type: DHW Utilized 0VAC 000 EXP-000 000 00 Legend: P - DHW Circ. P-P5 - s P DHW Circ. P Single Stage P3 Single Stage DHW P4 Single Stage P5 Single Stage HBX Control s Inc. 0 EXP-000 Manual Page 0

Input: 0VAC 60Hz 5A Relays: 40VAC 0A Demand Signal: 0-40V Central Processing Unit Model: CPU - 000 CAUTION, RISK OF ELECTRICAL SHOCK - DIS PRIOR TO SERVICING B C D Certified to CSA C. No 4 Conforms to UL Standard 873 Input: 0VAC 60Hz 5A Demand Signal: 0-40V Relays: 40VAC 0A Model: EXP-000 CAUTION, RISK OF ELECTRICAL SHOCK - Certified to CSA C. No 4 DIS PRIOR TO SERVICING Conforms to UL Standard 873 Input: 0VAC 60Hz 5A Demand Signal: 0-40V Relays: 40VAC 0A Model: EXP-000 CAUTION, RISK OF ELECTRICAL SHOCK - Certified to CSA C. No 4 DIS PRIOR TO SERVICING Conforms to UL Standard 873 Control s Inc. HBX EXP 000 Version.0 DUAL STAGING CONTROL DST 000-03 Dual system (multi-purpose) Hi/Lo fire heating boilers dedicated DHW boiler pumps are sequenced ELECTRICAL CPU-000 CENTRAL PROCESSING UNIT EXP-000 EXP. MODULE EXP-000 EXP. MODULE 0-40 v 0-40 v 0-40 v 0 A 0 A 0 A 0 A 0 A 0-40 v 0 A 0 A 0-40 v 0 A 0 A DS DS 7 8 9 0 9 0 0 0 0 0 3 3 3 3 L N GR L N GR L N GR L N GR DHW 0VAC L N Apply Control Signal or Program for Permanent Heat Demand 4VAC C R DHW DHW Outdoor P Hi Temp P Hi Temp P and P are Automatically Sequenced by the CPU-000 Stage Stage Stage 3 Stage 4 MECHANICAL Control Type: Dual Utilized 000 EXP-000 EXP-000 Legend: P - P - P3 - Injection P4 P5 s 000 00 00 0VAC P and P Hi-Temp s (Sequencing) Heat DHW Stage Stage DHW P4 P5 Load EXP-000 Manual Page

Control s Inc. HBX EXP 000 Version.0 Limited Warranty HBX Controls warrants each of its products to be free from defects in workmanship and materials under normal use and service for a period of 4 months from date of manufacture or months from date of purchase from an HBX Authorized Dealer, if within the above documented period after date of manufacture. If the product proves to be defective within the applicable warranty period, HBX on its sole discretion will repair or replace said product. Replacement product may be new or refurbished of equivalent or better specifications, relative to the defective product. Replacement product need not be of identical design or model. Any repair or replacement product pursuant to this warranty shall be warranted for not less than 90 days from date of such repair, irrespective of any earlier expiration of original warranty period. When HBX provides replacement, the defective product becomes the property of HBX Controls. Warranty Service, within the applicable warranty period, may be obtained by contacting your nearest HBX Controls office via the original Authorized Agent and requesting a Return Material Authorization Number (RMA #). Proof of purchase in the form a dated invoice/receipt must be provided to expedite the issuance of a Factory RMA. After an RMA number has been issued, the defective product must be packaged securely in the original or other suitable shipping package to ensure that it will not be damaged in transit. The RMA number must be visible on the outside of the package and a copy included inside the package. The package must be mailed or otherwise shipped back to HBX with all costs of mailing/shipping/insurance prepaid by the warranty claimant. Any package/s returned to HBX without an approved and visible RMA number will be rejected and shipped back to purchaser at purchaser s expense. HBX reserves the right, if deemed necessary, to charge a reasonable levy for costs incurred, additional to mailing or shipping costs. Limitation of Warranties. If the HBX product does not operate as warranted above the purchasers sole remedy shall be, at HBX s option, repair or replacement. The foregoing warranties and remedies are exclusive and in lieu of all other warranties, expressed or implied, either in fact or by operation of law, statutory or otherwise, including warranties of merchantability and fitness for a particular purpose/application. HBX neither assumes nor authorizes any other person to assume for it any other liability in connection with the sale, installation maintenance or use of HBX Controls products. HBX shall not be liable under this warranty; if its testing and examination discloses that the alleged defect in the product does not exist or was caused by the purchasers or third persons misuse, neglect, improper installation or testing, unauthorized attempts to repair or any other cause beyond the range of intended use, or by accident, fire, lightning or other hazard. Limitation of Liability. In no event will HBX be liable for any damages, including loss of data, loss of profits, costs of cover or other incidental, consequential or indirect damages arising out of the installation, maintenance, commissioning, performance, failure or interruption of an HBX product, however caused and on any theory of liability. This limitation will apply even if HBX has been advised of the possibility of such damage. Local Law. This limited warranty statement gives the purchaser specific legal rights. The purchaser may also have other rights which vary from state to state in the United States, from Province to Province in Canada and from Country to Country elsewhere in the world. To the extent this Limited Warranty Statement is inconsistent with local law, this statement shall be deemed modified to be consistent with such local law. Under such local law, certain disclaimers and limitations of this statement may not apply to the purchaser. For example, some states in the United States, as well as some governments outside the United States (including Canadian Provinces), may: Preclude the disclaimers and limitations in this statement from limiting the statutory rights of a consumer (e.g. United Kingdom); Otherwise restrict the ability of a manufacturer to enforce such disclaimers or limitations; or Grant the purchaser additional warranty rights which the manufacturer cannot disclaim, or not allow limitations on the duration of implied warranties. HBX Control s Inc. 0 EXP-000 Manual Page

Control s Inc. HBX EXP 000 Version.0 NOTES: EXP-000 Manual Page 3

Control s Inc. HBX EXP 000 Version.0 NOTES: HBX Control s Inc. 0 EXP-000 Manual Page 4

Phone: + (403) 70-009 Fax: + (403) 70-0054 Email: inf o @ hbxcontrols.com Web: www.hbxcontrols.com HBX Control s Inc. 456 - th Avenue SE Calgary, AB Canada TC K HBX Control s Inc. 0