THERMAL SYSTEMS, INC. Installation and Operation Manual

Similar documents
Heat Exchanger Piping Hook-up

TITAN FLOW CONTROL, INC.

OK, OKA, OKAF; ELD; ELDM; ELH; OKC; SC; SCA; SCAF; OK-LN; OKA-LN; OKAF-LN.

THE BARCLAY HUGGER CEILING FAN INSTALLATION INSTRUCTIONS

Installation & Maintenance Instructions

52 SAN LUCAS CEILING FAN

CELDEK Evaporative Cooler Module Installation, Operation, and Maintenance Manual. CELDEK Evaporative Cooler

52 BERKSHIRE CEILING FAN

52 BARSTOW CEILING FAN

AA-480-XX OUTDOOR THERMOELECTRIC COOLER ASSEMBLY USER S MANUAL

52 BAYTOWNE CEILING FAN

Standard and CELDEK Evaporative Cooler Modules Installation, Operation, and Maintenance Manual

Standard and CELDEK Evaporative Cooler Modules Installation, Operation, and Maintenance Manual

P/N CC-100. Coolant Circulator. Operation manual

MN908 No. 282C Replaces 282B LB7013

THE DAVENPORT CEILING FAN INSTALLATION INSTRUCTIONS

COLMAC COIL. Installation, Operation, and Maintenance ENG Rev A. Air Cooled Fluid Coolers. Contents. When you want Quality, specify COLMAC!

Owner s Manual Refrigerated Compressed Air Dryers Models F-200, 250, 300 & F350

INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS

52 STRATHMERE CEILING FAN

InstructIon Manual KrEs EQuIPMEnt stands

48 TAYLOR CEILING FAN

M Series Fan Filter Units

Turin LED Ceiling Fan

Owner s Manual Refrigerated Compressed Air Dryers Model F-100

ELECTRIC HEDGE TRIMMER

With Remote Control. English

STOP. SAFETY INFORMATION Please read and understand this entire manual before attempting to assemble, operate or install the product.

NEWGATE TECHNOLOGIES, INC.

INSTALLATION, OPERATION AND MAINTENANCE MANUAL FOR MODEL RH REMOTE HORIZONTAL AIR COOLED HEAT EXCHANGERS

55-Gallon Dispenser Package

READ AND SAVE THESE INSTRUCTIONS READ CAREFULLY BEFORE ATTEMPTING TO ASSEMBLE, INSTALL, OPERATE OR MAINTAIN THE PRODUCT DESCRIBED. PROTECT YOURSELF AN

THE NIKKO CEILING FAN INSTALLATION INSTRUCTIONS

COMPRESSED AIR DRYER. SAFETY... Page 2 MAINTENANCE... Page 5. INSTALLATION... Page 3 PARTS AND KITS... Page 6

OPERATIONS AND MAINTENANCE MANUAL FOR THE 8-TON TURF CART ENVIRONMENTAL CONTROL UNIT (ECU) PART NUMBER

Torrena 42 Ceiling Fan

R Series B & T2 Model

THE VALOR CEILING FAN INSTALLATION INSTRUCTIONS

CAR-MON DUST COLLECTORS SERIES 207, 2410, 3015

e Bath Fan with Light User s Guide

E1.5 ELECTRIC FAN HEATER

30 Misting/Oscillating Fan Model Number 01030

Camarillo 52 Ceiling Fan

Owner s Guide and Installation Manual

DRY AIR SYSTEMS, INC Metro Boulevard Maryland Heights, Missouri (314) fax (314)

FES - Series Portable Electric Heaters. YES - Series Suspended Electric Heaters CONTENTS

SPA BLOWER OWNER'S MANUAL XXXX, XXXX, XXXX, XXXX, XXXX, XXXX fax

The Monaco Patio. Please read and save these instructions

A910.8A Remote Water Chiller, 8 GPH A A / A A-220V TECHNICAL ASSISTANCE TOLL FREE TELEPHONE NUMBER:

40E ELECTRIC FAN HEATER

CLIMAGUARD Air-to-Air Outdoor Heat Exchangers INSTRUCTION MANUAL. Rev. H 2015 Pentair Equipment Protection P/N

40E ELECTRIC FAN HEATER

Republic Blowers. Ring Blower Side Channel Blower Regenerative Owner s Manual

MAN AUTO IMPORTANT INSTRUCTIONS PLEASE READ THIS MANUAL BEFORE INSTALLING AND USING APPLIANCE

48 MaxxAir Portable Evaporative Cooler Owner s Manual

52 CEILING FAN. Owner s Manual Models #50336, 50337

MC MC MC MC MC833130

Air Cleaning Equipment, Inc. 303 N. Main St. Broadway, NC iers.com

Stand Fan. English. Owner s Guide. Model F R

Operating instructions

Superdryer Dehumidifiers

NP317W

HIGH EFFICIENCY CIRCULATOR INSTRUCTION, INSTALLATION, MAINTENANCE AND REPAIR MANUAL

IW-25-2 Dehumidifier Installation & Operations. Manual

PORTABLE AFTERCOOLER MODEL CA-350 PORTABLE AFTERCOOLER/FILTER AFTERCOOLER OPERATION MANUAL

I.O.M. #116 7/10 INSTRUCTION MANUAL INSTALLATION OPERATION MAINTENANCE. Covers Models from 25 to 100 tons.

AquaStream. ½ HP Floating Fountain. Please Keep for Your Records. Model #AS05 6A, 120V/60Hz Owner s Manual UNIT IDENTIFICATION

60In. Ceiling Fan. Owner s Manual

UNDERCOUNTER LABORATORY REFRIGERATORS and FREEZERS Installation, Operation and Maintenance Instructions

Thermal Electric Wine & Beverage Chiller Model: WC-2463W. Instruction Manual

POLAR TEMP FARM MORTALITY UNIT OPERATION MANUAL

THE CHATEAUX 52"/60" UNI PACK CEILING FAN INSTALLATION INSTRUCTIONS

KPHE24 SERIES WATER-TO-AIR HEAT EXCHANGER

THE GUSTO CEILING FAN INSTALLATION INSTRUCTIONS

Thank You & Congratulations On Your Purchase of: ARBE Model # SS-206 Table Top Dust Collector

Model H1011.8/H1011.8HPS Water Cooler

ADVANTAGE SERIES KXRP28 AIR-TO-AIR HEAT EXCHANGER

15-Year Limited Warranty

Sanitaire. Owner s Guide. 10 GALLON Box Extractor SC6088 Series IMPORTANT

XT Series Thermostats

REFRIGERATED DROP-INS (2-6)FT-DI Installation and Operating Manual

KPHE32 SERIES WATER-TO-AIR HEAT EXCHANGER

REFRIGERATION KOOL-AIR INC. DIRECT DRIVE AIR COOLED CONDENSERS AND HEAT RECOVERY UNITS

Desiccant / Pump Dehumidification System. Model Operating Manual

PDF Created with deskpdf PDF Writer - Trial ::

True Hepa Shark Plus Canister Vacuum Model EP238 Use and Care Instructions

Engine Cooling Pulsator

KNHE30 SERIES WATER-TO-AIR HEAT EXCHANGER

18 MaxxAir Portable Evaporative Cooler Owner s Manual This Manual covers the EC18DVS MaxxAir Portable Evaporative Cooler.

How about Savings in Time, Money, Energy and Longer Life?

e Bath Fan with Light User s Guide

BX Series. Installation, Operation, Maintenance Instructions & Spare Parts

IMPORTANT INSTRUCTIONS - OPERATING MANUAL

Owner s Guide and Installation Manual

Owner s Guide and Installation Manual

Owner s Guide and Installation Manual

DUVAL 52 CEILING FAN MODELS #50201, Español p. 19 LISTED FOR DAMP LOCATION

55-Gallon Dispenser Package

Horizontal Bottle Cooler Installation and Operation Manual

IMPORTANT INFORMATION - PLEASE READ CAREFULLY

Transcription:

THERMAL SYSTEMS, INC. Installation and Operation Manual Revised September 2016

1. GENERAL SAFETY INFORMATION 1.1 Specification Never exceed the maximum allowable temperature or pressure ratings. Never exceed the maximum flow rate allowed by the size of the fluid ports. Be sure the system pressure is relieved prior to opening the cooler. Disconnect the electrical power and follow designated lock-out tag-out procedures before servicing. The fluid being cooled should be compatible with aluminum. 1.2 Safety Labels Catalog standard coolers are provided with ISO standard warning labels. Before installation and operation, the labels and their functions MUST be read and UNDERSTOOD. ISO standard labels are included on catalog standard product where the relevant hazard is in place. Two types of labels are present on AKG Thermal System s (AKGTS) coolers: mandatory action and hazard warning. These are shown in Figures 1 through 5. Figure 1: Mandatory action: read installation and operation instructions. Label present on all AKGTS catalog standard coolers and cooler assemblies. Figure 2: Mandatory action: lifting point location. Label present on all AKGTS catalog standard cooler assemblies with provided lifting eyes. Figure 3: Hazard warning: electrical shock. Label present on all AKGTS catalog standard cooler assemblies with alternating current (AC) or direct current (DC) electric powered motors. Figure 4: Hazard warning: hot surface. Label present on all AKGTS catalog standard coolers and assemblies. Figure 5: Hazard warning: rotating blades. Label present on all AKGTS catalog standard cooler assemblies with a rotating fan, regardless of power source. 1.3 Unpacking Prior to installation, unpack the unit and check for loose or missing pieces. Minor damage to the cooling fins can be corrected by gently bending them straight. Caps should be removed from the fluid connections and visually inspected to check for any debris or corrosion that may have occurred during storage or shipment. 1 of 5

2 INSTALLATION & MOUNTING 2.1 Place of Installation Care must be taken when choosing a location for the cooler assembly. A source of unhindered fresh ambient air flow is required for the cooler to perform to specifications. 2.2 Mounting in Closed Area When installing cooler in an enclosed space, sufficient ventilation must be provided to exhaust the hot air and replenish with cool air. The cooler must be placed no less than one fan diameter within an obstruction (i.e. wall, reservoir tank, machinery); recirculation of the exhaust air can occur as well as reduce the fan performance due to increased resistance. All of the above will result in decreased cooler performance. 2.3 Outdoor mounting Standard motors are totally enclosed fan cooled (TEFC) motors which provide protection from normal weather. Motors must be shielded when exposed to direct jets of water as any moisture ingress has the potential to short the motor. For high ambient temperature environments, the motor must have an insulation rating suitable for operation in those conditions. Please contact AKG Thermal Systems as other motor options may be available for extreme environments. When exposed to low outside temperatures, over pressurization of the cooler can occur due to the oil or fluid becoming highly viscous. To avoid this, sound engineering practices must be employed. This could include manual, pressure, or temperature controlled bypasses and other hydraulic safety measures to reduce the strain on the cooler in cold start-up conditions. 2.4 Mounting in Dirty Ambient Conditions Coolers installed in environments that have particulates, debris or oil droplets within the airflow will be need to be cleaned regularly to ensure free flow through the cooling fins on the heat exchanger. Blocked air passages will reduce the heat exchange efficiency of the unit. Failure to clean the cooler will result in decreased performance. 2.5 Manner of Mounting Mounting is usually vertical by means of existing legs or mounting brackets. The cooler must be mounted in the manner it was designed to fit the application. The cooler assembly must be fully secured before operation. Improper mounting can result in damage to the cooler and the surrounding environment or bodily harm. It is recommended that a filter be used ahead of the cooler to prevent debris or foreign material from causing blockage in the fluid rows in dirty environments. All piping must be properly supported to prevent strain on the cooler. Pipe sizes should be based on the oil flow and pressure drop requirements, not the oil coolers connection size. Where excessive vibration may be a concern, flexible connectors are recommended to be used to eliminate stress. 2.6 Electrical Connection Installation should be completed by a certified electrician, and must comply with all local codes. The fan motor must be connected to a power supply that matches that of the motor nameplate. Voltage may vary 10% of what is posted on the motor nameplate. Be sure to provide proper fusing to prevent a possible motor burnout. 2 of 5

2.7 Start-Up The fan blade must be spun by hand prior to hookup to make sure it has proper clearance. Check fan air flow to be sure it matches the directional arrow on the unit. Make sure oil connections are properly sealed. 2.8 Circuit Connection 3 CHECKS In hydraulic systems and also in intermittent operation of lubricant oil systems, peak pressures may rise in excess of the permissible operating pressure. Due to their short duration, these spikes are traceable only by a data acquisition system capable of sampling data at 500 to 1000 hz. Experience has proven that spring loaded excess pressure valves are often not sufficient for reducing spikes and intermittent pressure spikes. If required coolant temperature is not attained after start of operation, or if the temperature gradually rises during operation, check for the following: 1. Speed and direction of fan 2. Fan engagement within shroud 3. Electrical connection 4. Coolant quantity 5. Cooling air flow restrictions 6. Soiling condition of cooling surface 7. Entering temperatures of cooling air and coolant Deviations from given installation data, blocking to coolant or coolant air flow, or soiling of cooling surfaces can cause reduced cooler performance. Such deviations must be eliminated for safety and proper cooling function. 3 of 5

4 MAINTENANCE AKGTS cooling systems require no particular maintenance. However, in operation with heavy soiling, regular cleaning must be carried out. Be sure to disconnect the power supply and follow any designated lockout and tag out procedures prior to servicing. Inspect the product regularly for corrosion and clogged heat transfer surfaces. 4.1 External Cleaning of Air Side This can be done by either washing the cooler with a mild cleaner (compatible with aluminum), or with compressed air. A power spray washer works well. Care should be taken not to damage the fins. The direction of stream shall be parallel to the fins in order not to damage. Cooler needs to be dried completely before restarting operation. 4.2 Internal Cleaning of Coolant Side The cooler must be disconnected from the cooling circuit and flushed with clean oil compatible with the cooling system. Flushing in the opposite direction of typical flow is recommended to remove any blockages. 4.3 Motor Lubrication Most of the fan motors 5 horsepower and below have sealed bearings and do not require any lubrication. For Motors that require lubrication, add grease every 2000 hrs. Follow instructions for grease specifications posted on the motor tag. Do not over grease the motor bearings. 4.4 Storage Product should be stored in a dry area that has a constant temperature. Temperature changes in the storage area cause condensation to form inside the heat exchanger. This condensation then causes corrosion which causes product failure. This failure is not covered by the guarantee. If these criteria cannot be met, the cooler should be stored in a sealed plastic bag with desiccant added to absorb the moisture. Storage term: 6 Months: No specific internal corrosion protection procedures are required. All openings should be sealed with plastic plugs 7-24 Months: Coolers should be flushed with oil and all openings re-sealed with plastic plugs. 25+ Months: Coolers should be completely filled with oil and sealed. These coolers should be flushed, inspected and re-sealed every 24 Months. 4 of 5

5 PRODUCT WARRANTY All heat transfer products manufactured by are guaranteed against defective material or workmanship for one year of service after purchase by validated end user or 2000 hours service, whichever comes first. Warranty will not apply after 18 months from original ship date from AKG Thermal Systems, Inc. Warranty for components such as fans, motors, and other components when used on an AKG Thermal Systems, Inc. product will be provided by component manufacturer. Any product alleged defective under the warranty period must be returned to unless otherwise specified by AKG Thermal Systems, Inc. Transportation charges are to be prepaid by the customer, unless previously agreed by Warranty consideration is subject to factory inspection. AKG Thermal Systems Inc. is not responsible or liable for products damaged through carelessness or abuse. Careful inspection of products should be made by the customer before returning to for warranty. If factory inspection proves any parts defective, repair or replacement of defective parts will be made without charge to the customer. Transportation charges will be prepaid for returning product back to the customer. Liability under this guarantee is limited to the repair or replacement of the defective parts, and shall in no event include consequential damages of any nature. AKG THERMAL SYSTEMS, INC WARRANTY IS "AS IS" AND WILL BE BOUND BY NO OTHER WARRANTY, EXPRESSED OR IMPLIED, EXCEPT THOSE HEREIN SET FORTH. Any attempt at local repairs automatically cancels this warranty. Returned products must be properly packaged. Adjustments cannot be made on any returned product which is damaged in transit due to poor packaging, and a charge will be made to cover cost of repair. If after factory inspection, product is found not to be defective, an inspection and packaging charge will be made and return freight is not prepaid. 6 CONTACT INFORMATION Mailing Address Mebane Industrial Park 7315 Oakwood Street Extension Mebane, NC 27302 Phone: (919) 563-4871 Email: sales@akgts.com Shipping Address 809 Mattress Factory Road Mebane, NC 27302 5 of 5