Motor Lock Manual 840C-50, 841C-50, 841C-35, 851C-35, 851C-50, 850C-50. ASSA ABLOY, the global leader in door opening solutions.

Similar documents
ABLOY EL460, EL461, EL560, EL561 Europrofile handle controlled locks

ABLOY EFEND. New name for security

DE5300 Delayed Egress System. General Information

Remote Chexit Module (RCM) System. General Information

Table of Contents Auxiliary Locks

HD72 Euro Profile Mortice Lockcase. The high performance lock that goes beyond the standard. ASSA ABLOY, the global leader in door opening solutions

KP-100A BACKLIT DIGITAL KEYPAD FOR ELECTRIC LOCK AND SECURITY SYSTEM INSTALLATIONS

ABLOY DA460 SWING DOOR OPERATOR. Installation and commissioning manual

Yale Real Living Assure Lock Push Button Deadbolt Installation and Programming Instructions (YRD216)

ASSA Lockcases. ASSA ABLOY, the global leader in door opening solutions

Alarmed Exit Hardware

An ASSA ABLOY Group brand. 4800LN Series. Interconnected Locks

Installation Instructions. PS902 Power Supply. These instructions cover the following parts: PS902 Power Supply Specifi cations:

4800LN Series Interconnected Lockset. An ASSA ABLOY Group brand

CD30 Codoor. Instruction Manual

MODEL KP-200 VANDAL RESISTANT & WEATHERPROOF FLUSH MOUNT DIGITAL KEYPAD DESIGNED FOR ACCESS CONTROL APPLICATIONS

Ironmongery Schedule. Prepared for: ABC Architects Project Title: Education Vertcial Market Our Ref: ABC123

Panic Exit Devices. We take the worry out of protecting what s valuable to you. Lockwood: no worries.

Ironmongery Schedule. Prepared for: ABC Architects Project Title: Healthcare Vertcial Market Our Ref: ABC123

ELECTRIC LOCKS. Europrofile range

INSTALLATION INSTRUCTIONS 101-DE/101-KDE

Access Control, Code Lock

5, SE GÅNGHESTER,

World Strike 77 series Adjustable. The whole range for quick and easy installation. ASSA ABLOY, the global leader in door opening solutions

Yale Real Living Touchscreen Deadbolt Installation and Programming Instructions

Hardware Selection Process

DOLKPS1KB Programming & Installation Manual

Nest x Yale Lock Installation and Programming Guide. Back button Check (Set / Continue) Keypad

Yale Real Living Key Free Push Button Deadbolt B1L Installation and Programming Instructions

Ironmongery Schedule. Prepared for: ABC Architects Project Title: Transport Vertcial Market Our Ref: ABC123

Multi-Mode Annunciators

ALARMED EXIT HARDWARE

Accessories. Desk Controls. Break Glass Emergency Door Release SECURITY DOOR CONTROLS

Ironmongery Schedule. Prepared for: ABC Architects Project Title: Hospitality Vertcial Market Our Ref: ABC123

Ironmongery Schedule. Prepared for: ABC Architects Project Title: Commercial Vertcial Market Our Ref: ABC123

An ASSA ABLOY Group brand. 4300LN Series. Grade 2 Tubular Lever Locks

CI/SfB Xt7. The global leader in door opening solutions 1

Hi-O Technology. Bringing Network Intelligence to the Door. Hes HID NORTON Sargent Securitron 1

KSUF CONTROL AND MONITORING UNIT. Description. Installation Designed for wall installation.

Modular Fillerplate Subassembly P/N: X Endcap P/N: Strike *, P/N: " Narrow Stile Plastic Template. Mortise.

High Security Locking. Product Catalogue

CI/SfB. Xt7. Locks and latches

Accessories DESK TOP CONTROLS MODELS SPECIFICATIONS MODELS SPECIFICATIONS UNDER DESK TOP MOUNTING MINI DESK TOP CONSOLE

4300LN Series Grade 2 Tubular Lever Locks. An ASSA ABLOY Group brand

Power Transfer Devices. Access Control Accessories. How To Order. How to Order

ABLOY FIRE DOOR CLOSING SYSTEMS

KEYLESS WIRELESS DIGITAL DEADBOLT

EXD-HP1/2 Stand-alone Superheat/Economizer Controller

YALE LOCKSETS. Yale Locksets offer protection and convenience for your business, home and your family.

RELEASE DEVICES RELEASE DEVICE-WPS MODELS A/B INSTALLATION MANUAL U.L. LISTED CANADIAN LISTED CSFM: :100 GENERAL DESCRIPTION:

DUAL MONITORED INPUT/OUTPUT UNIT BN-305

For more information on Abloy UK visit EXIT HARDWARE

SECTION HARDWARE

Lubrication cycle IP Enclosure Rating. 110 VAC, 220/230 VAC (50/60 Hz) Alarm Fault Relay Contacts. IP-55 (Liquid tight connector)

WIRING DIAGRAM AND INSTRUCTIONS

Pocket Catalogue. ASSA ABLOY, the global leader in door opening solutions

705 Emmett Street Bristol, CT DynaLock MODEL 3101C-TJ101 DELAY EGRESS SYSTEM WIRING INSTRUCTIONS

Wireless Access Control Light Commercial Lockset. WIACCOCAT - Wireless Access Control Light Commercial Lockset Catalogue_

INSTRUCTION MANUAL T119 1MN0110 REV. 0. operates with ISO9001 certified quality system

shine TM Manual User guide and installation instructions The global leader in door opening solutions

Security Door Closer Safe and secure by design. ASSA ABLOY Door Controls

Accessories. Desk Controls. Break Glass Emergency Door Release SECURITY DOOR CONTROLS

DS3MX-E-I. Installation Guide. 3 Zone Mini Control Panel

ACSI MODEL 1410 POWER SUPPLY INSTALLATION INSTRUCTIONS

Accessories. Desk Top Controls

Ironmongery Performance Specifications

SOLID STATE SECURITIES, INC. THE "SS90" SERIES RELEASE DEVICES MADE IN THE U.S.A. SS90-WPS MODEL A/B INSTALLATION MANUAL

An ASSA ABLOY Group brand Series. Grade 2 Cylindrical Knob Locks

M2500 Engine Controller Installation Manual

SCHMIDT LED Measured Value Display MD Instructions for Use

Secure Connect. We take the worry out of protecting what s valuable to you. Lockwood: no worries.

INSTALLATION INSTRUCTIONS EA SERIES DOOR PROP/EXIT ALARM

Constant voltage 3-phase rectifier.

Egress Devices for Code Compliant Access-Controlled Egress Doors

Firefly II Multi Voltage RELEASE DEVICES. Firefly II & IIB-MV INSTALLATION MANUAL

AXS Strikemaster Engineering Manual

FEC400 Series. Installation Manual

SMARTair SOLUTIONS GUIDE. Providing complete specifications utilising ABLOY SMARTair. Page 1

SC Installation, Operation & Application Guide

MADE IN THE U.S.A. MODELS A/B INSTALLATION MANUAL

THE "SS90" SERIES RELEASE DEVICES MADE IN THE U.S.A. MODELS A/B INSTALLATION MANUAL

ES860 OPTICAL TURNSTILE INSTALLATION AND OPERATION MANUAL PRESENT CARD

HEIGHTS KEY LOCK & SAFE 920 San Mateo NE Albuquerque, NM Contact us for more information

Cylinders and Key Systems

Cylinder Mortice Dead lock Lockcase(mm) A=87 Backset (mm) B=55. Follower (mm) 8 Latch Bolt

SARGENT Beacon TM. A Technical and Informational Newsletter From Dugmore & Duncan. Summer 2009 Vol. VIII - Issue II L

Lightning Warning System: LWS MK-II. User's Guide. KOREA EMI Technologies Co.,Ltd , Jangam-ri, Majang-myeon, Icheon-si, Gyeonggi-do, Korea

Key in Knob & Key in Lever

2409/2900. Fire Guard

GUIDELINIE ECB S R10. March European Certification Body GmbH

EHT/EHTD. Electromechanical Closer-Holder Release Devices

HA-263K HA-263D. OWNER'S MANUAL Installation And Operation 8-ZONE ALARM CONTROL PANEL FOR HOME AND OFFICE PROTECTIONS OPEN THE CABINET FOR SERVICE

MECHANICAL LOCK CASES Technical descriptions

Synergis Master Controller 2.2 Integration Guide for Assa Abloy Aperio- Enabled Locks

ASSA Vinga. A complete series of handles. ASSA ABLOY, the global leader in door opening solutions.

MODEL B2 INSTALLATION MANUAL

Interrupted Ignition Series Oil Primary Control

MVP-D-TEK Vehicle Loop Detector 9 Volts DC to 240 Volts AC. Operating Instructions

FIREFLY II PLUS RELEASE DEVICES INSTALLATION MANUAL

The most user friendly Security Alarm System L S Section 1 Overview of System Section 2 Planning your Installation

Transcription:

Motor Lock Manual 840C-50, 841C-50, 841C-35, 851C-35, 851C-50, 850C-50 ASSA ABLOY, the global leader in door opening solutions.

Contents. Installation.... 3 Connection.... 4 Factory reset... 4 Latch bolt 840C/850C.... 5 Technical data.... 6 Accessories.... 7 Maintenance of motor locks.... 8 Class 4 och Class 5.... 9 SSF 3522 Mode.... 9 Accessories SSF 3522.... 9 Quick guide.... 11 För manual på svenska, var god vänd. ASSA ABLOY, the global leader in door opening solutions, dedicated to satisfying end-user needs for security, safety and convenience. ASSA AB P.O. Box 371 SE-631 05 Eskilstuna Sweden phone +46 (0)16 17 70 00 fax +46 (0)16 17 72 10 Customer support: phone +46 (0)771 640 640 fax +46 (0)16 17 73 72 e-mail: helpdesk@assa.se www.assa.se Order information: Dokument XXXXXX Artnr XXXXXX Grafisk form: AB Typoform ASSA AB, 2016

Installation A B A B C C 1 Mark centerline A (Face plate) when you have decided the position of the lockcase. 2 Mark B and C 3 Use a 20 mm drill bit to get the correct depth for the lockcase, 82 mm for 50 mm backset and 48 mm for 35 backset. Do not use force to push the lockcase into the mortice. 4 Drill the 42 mm hole (B and C) for cylinder and handle through the door. 5 Mortice the center faceplate into the edge of the door, this has a depth of 3 mm and radius 11. 6 Make the mortise for the striking plate. Drill 5 holes Ø20 with a depth of 26 mm. Use a chisel to fit the strike plate into the mortise. Use a chisel to make the outer profile (depth 4 mm for 1487-X). Predrill the four holes (Ø3 mm). 7 If the internal door sensor is used. Mount the magnet into the striking plate. The door sensor position is behind the date mark on the forend. Assa recommends a clearance of 3 mm between forend of lock case and strike plate. Adjust the door seal pressure. Before fitting the lock to a firesmoke resisting door, the fire certification should be examined. 3

Connection To connect a motor lock to the Hi-O bus a four wire cable is used; two for power and two for communication. Use supplied cable EA226 (10m), with connector, at installation. White CAN high Brown CAN low Green + 12 24VDC stab Yellow 0 V The cable can be connected anywhere on the Hi-O bus. Factory reset 1 Switch off power to the lock. 2 Make sure that the door is open (no magnet on the lock door sensor). 3 Turn on power. 4 Within 30 seconds, toggle / switch group switch 6 times back and forth. 5 Switch off the power. 6 Turn on the power. 7 Verify that the LED next to the group switch is turned on ( Steady light). Explanition for LED Steady light= Factory mode, not initiated LED off= Initiated Flashing LED (2Hz)= Wrong DAC lock already initiated against another DAC. Flashing LED (10Hz)= Timeout wait 240 sec (4 min) then initiate DAC or reset the lock. See the quick guide. 4

Latch bolt 840C/850C 1 2 3 4 1 Unmount the screws (Torx T20). 2 Be careful the pin and socket can fall out. 3 Unmount the plastic. 4 Turn the latchbolt. 5 Assembly the plastic. 6 Assembly the pin and socket. 7 Assembly the forend. 8 Assembly the screws (Torx T20). Door monitor The placement of the door monitor is under the date mark on the forend. 5

Technical data Currency consumption (ma) Lock Type Idle Running Assa Motor Lock 841C/840C/850C/851C 50mA Max 445 ma at 24VDC Cable Type: EA226, 10 m Max length Total 50 m Cable length Cable area 12V 20 m 0,3 mm 2 30 m 0,4 mm 2 40 m 0,5 mm 2 50 m 0,6 mm 2 Contents in package Complete package: Lock case, Drill protection, DAC-500, Cable EA226, Strike plate, Magnet, Fitting screws, Manual Half package: Lock case, Drill protection, Cable EA226, Strike plate, Magnet, Fitting screws, Manual Lock case: Lock case, Drill protection and Manual DAC530 package: Lock case, DAC530, cable EA226, Magnet for striking plate. 6

Accessories ASSA 840C-50 841C-50 850C-50 851C-50 841C-35 851C-35 Cylinder type Round, oval Oval Strike plate 1487-1, -2*, -3, -4, -5 1487-8* Cable EA226* EA226* Cable loop EA280, EA281* EA280, EA281* Thumb turn Round thumb turn cyl. 13 Oval thumb turn cyl. 03 Oval thumb turn cyl. 03 Cylinder accessories 3212 4559 SCD Plastic dome accessory 8065, with round thumb turn cyl. Lever handle Standard / NA NA Security accessories 4559 SCD * Supplied in set packages 7

Maintenance of motor locks Follow this manual thoroughly to maintain characteristics of the motor lock. Do not diverge from this manual without advice from ASSA. Warranty fails if product is: Wrong installed. Opened by unauthorised personnel (broken seal) or if cables/connectors has been cut. Fitted with accessories or parts not recommended by ASSA. Maintenance: Approximately twice a year, a small amount of designated grease should be applied on latches and bolts. Highly frequented doors may need maintenance with shorter intervals. Electric parts need NO maintenance. To maintain desired operation and security level of installed unit, it is of great importance to check and adjust the entire door environment: Lock case and strike plate Lock accessories (Lever handle, thumb turn etc.) Hinges, framework and door threshold (sill). Door closer. NB!! Never use lubricants containing graphite or solvent, use designated grease from ASSA only. If any uncertainty regarding installation, maintenance or warranty occurs, please contact ASSA or your local supplier. The safety features of this product are essential to its compliance with EN 14846. No modification of any kind, other than those described in these instructions, is permitted. The locks 841C and 851C must always be combined with a door closer which is proven by test to keep a door in closed position in the event of fire. The lock case is intended to sit in single or double acting wooden, aluminum or steel door. EN14846 -X8E----- (850C,851C,840C,841C) 0402-CPR-SC0155-14 CE EN14846 3 X 8 E 0 L 7 1 3 (850C,851C) SC0860-14 Performance EN14846 3 X 8 E 0 L 5 1 3 (840C,841C) SC0173-15 Performance EN 50130-4 4P03456-E6 (841C-35,851C-35) 4P03456-E7 (84XC-50,85XC-50) EMC EN1634:1 E90 4P01152 Fire SFF3522-1093 Class 4 /Class 5 8

Class 4 and Class5 To meet the Class 4 and Class 5, the following requirements must be met. For Class 4 and Class 5 requires that the controller is installed in a protected space with at least grade 3 locking. DAC564 controller must be installed in the SSF 3522 mode. SSF 3522 Mode To install a motor lock SSF 3522 mode you should do this: 1 Initiate lock case. 2 Turn off the power. 3 Dip switch 3,7 & 8 in the On position. 4 Turn on the power. In 3522 the SSF mode will relay then have the following characteristics: Relay Lock Lock indicator, active for 15 seconds at locked. Relay Alarm Unlocked indication active for 60 seconds when unlocked. Relay1 RC64 (Security locked) door closed and deadbolt out. Relay2 RC64 (Unlocked) deadbolt inside. Relay3 RC64 (Unlocked, with delay). Relä4 RC64 (Closed Door). Relä5 RC64 (Summer, Forced door). Relä5 RC64 (Summer, Forced door). RELAY6 RC64 (Tamper) Relay energized in alarm, the alarm must be installed. Accessories SSF 3522 All components belonging to the locking device (such as lock cases, striking plates and Door reinforcement) shall have the same classification according to SSF 3522.. 9

R5 (4x) 25 (851-35) 22 (841-35) 48 35 3 26 R5 (4x) 225(841-35) 177 24 25,5 Cylinder 12 200 59 228(851-35) 10 58 225 24 25,5 62,5 27 R5,5 (2x) 20 M5 (2x) 22 20 3 50 82 27,6 Drill for screw 4,0 x 25mm 42 225 170 27,6 Drill for screw 4,0 x 25mm 57 111 57 111 42 2x) 10

Quick guide Installation and initiation/pairing of Hi-O motor lock and DAC 1 Connect the cables of the motor lock to DAC (White = CAN H, Brown = CAN L, Green = 12 V, Yellow = 0 V). 2 Make sure that the termination jumper link in DAC is set to ON. 3 The input Door monitor should be jumper linked and the Button input open, in most cases. 4 Set all DIP switches to OFF, applies in most cases. (For more information, see Initiation matrix). 5 Turn the power on. (Blue DWG LED starts flashing.) Wait until blue DWG flashes fast, can take up to 3 minutes as a maximum. DO NOT TURN OFF the power during the initiation. 6 When yellow PWR LED is lit and blue LED flashes fast the initiation is done. (If blue LED flashes fast and yellow PWR LED is unlit the initiation has failed.) 7 Switch off the power. 8 Set DIP 8 for stand alone mode. See also on page 12 for different running/function modes. 9 Turn the power on and control the function. For further information, see the user guide. 11

Initiation Door monitor switch in motor lock and fail safe/safe secure electric strike Door monitor input DIP 7 Electric strike Explanation/result. Closed OFF Sensor in motor lock active Safe secure function on electric strike (Normal mode). ON Sensor in motor lock active Fail safe function on electric strike. Open ON Sensor in motor lock inactive Fail safe function on electric strike. OFF Sensor in motor lock inactive Safe secure function on electric strike. Button input behaviour at initiation Button input: open at initiation Button input: closed at initiation The input will be level triggered, i.e. DAC will set the door unlocked as long as the input is closed, which is normal mode. The input will be flank triggered, i.e. DAC will lock the door according to set time if the input remains closed while running. Information ASSA motor lock When there is an LED mounted beside the switch on the case (LED is only visible with the lock in the hand). This locks you can do a factory reset on the lock. The LED function is to facilitate the installation and troubleshooting. Steady light LED off Flashing LED (~2Hz) Flashing LED (~10Hz) Factory mode, Not initiated. Initiated "Wrong DAC" lock already initiated against another DAC. Timeout. Initiate DAC again or reset the lock as shown below. Factory reset of ASSA motor lock, with LED beside group switch See page 4. 12

Quick guide Configuration of DAC as control unit 17-24V AC/DC Vit/White Brun/Brown Grön/Green Gul/Yellow - Dag/Natt, Day/Night Öppna/Open DIP8=ON, DIP7=OFF: Function of relays and inputs KP1 in DAC530 and DAC564 Relay & Input Relay Out (Lock) Relay Out (Alarm) IN 13&14 Door monitor IN 11&12 Button Function Electric strike Alarm Bypass Door position in Open KP2 in DAC564 and DAC530 with relay board 400RC64 Relay RE1 Relay RE2 Relay RE3 Relay RE4 Relay RE5 Relay RE6 IN1 IN2 Bolt out Bolt in Unlocked Door position Buzzer Tamper Day/Night Not used IN3 Alarm blocking Normally closed IN4 Not used With DIP8 = ON, DIP7 = OFF: The unlock time is set with DIP1 4 13

DIP8=ON, DIP7=OFF: Function of relays and inputs KP1 DAC530 board DIP 3 DIP 4 Function Out Relay (Lock) Out Relay (Alarm) IN 13 & 14 Door monitor IN 11 & 12 Button OFF OFF Standard Electric strikes Alarm Bypass Door position in Open ON OFF EMLA Bolt out. The relay takes hold for 15 sec Bolt in. The relay takes hold for 15 sec Door position in Open OFF ON Invalid mode OFF ON Invalid mode (KP2) DAC400RC64 relay board (Applies to Standard & EMLA) RE1 RE2 RE3 RE4 RE5 RE6 IN1 IN3 Bolt out Bolt in Unlocked Door position Buzzer Tamp D/N Alarm blocking With DIP8 = ON, DIP7 = ON: The unlock time is set with Sec./DIP 1 2 4 8 ON 12 ON 16 ON ON Information! DAC and other Hi-O products have a function inhibiting them for 240 seconds (4 minutes) if the initiation fails more than three times, when the time expires you have one more chance to try to initiate. Note that the time only counts when the Hi-O unit has power. After initiation DAC and other units cannot be moved to another door unless they are uninitiated from each other, see user guide. For ASSA motor lock see Factory recovery ASSA motor lock. For more information, see manual. 14

15

16