Capri R CH only, oil-fired, cast iron boiler

Similar documents
Capri B Cast iron combination oil-fired boiler with water tank

C Elba Dual. Cast-iron, floor-standing boiler. High quality Italian product. Life-enhancing heat

C Bali R. Cast-iron boilers with atmospheric gas-fired burner. Life-enhancing heat

C Nias Dual. Wall-hung boilers, forced draught, sealed chamber with storage tank. For indoor installation. Life-enhancing heat

C Tahiti. condensing

Condensing, pre-mixed, wall-hung gas boilers with water tank

HORIZONTAL HOT WATER CYLINDER WHPF BO

MINORCA KC - KR - KRB 24

IST 03 C ELBA DUAL INSTALLATION, USE AND MAINTENANCE

FORMENTERA KC - KRB - KR

Light oil - kerosene burner

ANTEA KC - KR - KRB

WALL HUNG GAS BOILER FOR C.H. AND PREDISPOSTION FOR INSTANTANEOUS D.H.W. PRODUCTION (with optional kit) MODELS 34,8 kw (depotenziata) 50 C

1 VICTRIX ZEUS Superior kw I features

CITY PLUS. Wall-hung condensing boilers. ErP 24 HE 30 HE. Ready

Light oil burners. One stage operation

Light oil / kerosene burner

SPECIFICATIONS - NIKE

Ideasandformsinevolution

2.1 BOILER ROOM BOILER ROOM DIMENSIONS 2.3 CONNECTING UP SYSTEM 2.4 CONNECTING UP FLUE 2.5 ELECTRICAL CONNECTION

Floor standing boilers. RMG Mk.II RS Mk.II

VICTRIX 50 1 SPECIFICATIONS. Wall mounted condensing boilers

IST 03 C CYLINDER WHPF BM USE AND MAINTENANCE HANDBOOK

Easyfire Standalone biomass pellet boiler

AVIO kw Export 1 FEATURES. Wall-mounted with storage tank

The mechatronics of EVE 05

Oil burners Brûleurs fioul Stookoliebranders

RMG MK. II RMG Mk.II RS Mk.II RMG Mk.II RS Mk.II

Power X High Power Condensing Wall-Hung Boilers

Remove the Testing Certificate from inside the combustion chamber and keep together with the instructions manual.

VICTRIX Superior kw Export VICTRIX Superior kw X Export

ATMOSPHERIC GAS BOILER INSTALLATION, OPERATING AND MAINTENANCE MANUAL

Pure technology. Clean design and practical panel board with wide Power save display !DEA AR 23 !DEA RS !DEA AC 23 !DEA CS

Power X High Power Condensing Wall-Hung Boilers

INSTALLATION AND OPERATION MANUAL

SIME FORMAT WALL HUNG BOILERS MODEL 34i AND MODEL 34e. cod A

STILE BEAUTY AND TECHNOLOGY

ACCUMULATION OF EUROPEAN CLASS

24-28 kw Conventional Combi Gas Boiler. Lawa / LawaPlus

So old fashioned... As the combustion chamber is completely room sealed, it does not release any smells and does not dirty.

Mynute Green k. Condensing Wall-Hung Boilers. Residential Heating

CONDOR RAPID CONDOR RAPID/V STEAM FORCED CIRCULATION. Design pressure 11,76 bar Steam production from 45 to Kg/h

VICTRIX 90 VICTRIX 115 Wall-hung condensing boilers for high power

VERY LOW TEMPERATURE CONDENSING UNIT Low NOx Class 5 MODELS SEASONAL EFFICIENCY A A A A A A A

CAST IRON ATMOSPHERIC BOILERS

CODE MODEL TYPE PRESS 60 N 616 T PRESS 60 N 616 T80

NIKE Star 24 3 E. Instantaneous wall-hung with open chamber boilers. NIKE Star 24 3 E

CALEFFI. SATK wall-mounted heat interface unit Fitted for connection to DHW storage. SATK40 series 01216/14 GB

RL/1 SERIES. One Stage Light Oil Burners FIRING RATES LIGHT OIL RL 34/1 MZ kw

Ciao Green Condensing Wall-Hung Boilers

HIGH POWER. VICTRIX PRO 2 ErP. High power, wall-hung condensation boiler

Wall-hung boilers. Spare parts catalogue. ecotec plus

Mynute Green Condensing Wall-Hung Boilers

TermEfekt USER S MANUAL AIR HEATER. Model PGA 14

BIOMASS BOILER ATTACK PELLET 30 AUTOMATIC PLUS

INSTALLATION AND MAINTENANCE MANUAL BLITZ FD_

LIBRA DUAL INSTALLATION USE AND MAINTENANCE. Italian product. High quality IST 04 C

thea 35 MR/MN Kondens Wall-mounted condensing boiler

TRADITIONAL NIKE/EOLO STAR. Wall-hung combi boilers

Heating, Air Conditioning, Ventilation. Отопление-Кондиционеры-Вентиляция. MTM 8-30 kw UNIVERSAL OIL HEATER OPERATING MANUAL

MAINTENANCE AND SERVICE GUIDE

Parts Available from

SPARE PARTS EXPLODED VIEW GAS WALL BOILERS Model CLAS. R EN - Edition 01-01/02/2007

With a power output ranging from 13kW to 24kW, they provide the flexible answer for the majority of traditional installation scenarios.

TAHITI CONDENSING KR 55 - KR 85

TWO STAGE HEAVY OIL BURNERS

SPARE PARTS EXPLODED VIEW GAS WALL BOILERS Model EGIS - AS. R EN - Edition 03-01/03/2008

Savile Plus. Steam Boiler. Suitable for Pressure Jet burners Oil, gas or dual fuel firing. Outputs kg/h

WHE 2.24 / WHE 2.24 FF

Firebird Enviromax Condensing Range

CONTROL CABINET for cascade boiler systems

Mikrofill Ethos Condensing combination boiler. Maintenance Instructions 24cc

Metropolitan. Steam Boiler. Suitable for Pressure Jet or Rotary Cup burners Oil, gas or dual fuel firing. Outputs kg/h

THE PERFECT CONDENSATION

RK 50. High Efficiency Condensing Wall Hung Boiler Heating Only. Suitable for Cascade Systems SEDBUK BAND A CE 0694 TA01E011.A0405 TA05E011.

Calder. Steel Hot Water Boiler Suitable for Pressure Jet burners Oil, gas, LPG or dual fuel firing. Outputs kw. Calder Model

Technical information. Remeha P200. Pressurized boiler. Heat output: kw

User Manual RBS 24. for model CE series ENERGY. Wall mounted instantaneous combi boiler room sealed chamber

GAS FIRED ATMOSPHERIC ELECTRONIC VERSION kw

INSTALLATION AND OPERATING INSTRUCTIONS JAKA HFD JAKA HFS

Operating manual. Pellet boiler. Orlan Pellet ISO 9001

Single stage operation oil burner

Heating Equipment. gas boilers RX GB. installation and servicing instructions

Rapid. Suspended Warm Air Heater. Caring for the environment!

Submittal Data GA Line AYF Series Commercial and Specialty Chiller-Heaters 2 or 4 pipe Gas Fired Absorption Chiller-Heater Cooling and Heating

ECONOFLAME R6000 GAS FIRED CONDENSING HOT WATER HEATER SUPPLEMENT

24/31-28/35-33/40 kw Premix System Condensing - ErP Combi Gas Boilers. Enerwa / EnerwaPlus.

User Manual for model

Servicing Instructions Type C Boilers G.C.N: LEAVE THESE INSTRUCTIONS ADJACENT TO THE GAS METER

TABLE OF CONTENTS. IMPORTANT Please read this manual carefully.

General catalogue COMMERCIAL AND TECHNICAL INFORMATION. Commercial Range. March 2015 Edition

AIREX 2S WOOD PYROLYSIS SUCKING FAN

The guarantee on this appliance is valid for 12 months from the first day of installation.

5 YEAR ADVANCE PLUS WARRANTY. High efficiency condensing combi and system boilers

Burner Comparisons. Typical Competitor s Burner

Room sealed circuit appliance sold without the terminal or the combustion air supply and exhausted gas ducts. TYPE C 63 TYPE B TYPE B 23

BIOMASS BOILER DUAL THERM

TAHITI DUAL HC - HR INSTALLATION, USE AND MAINTENANCE. Italian product. High quality

VIESMANN VITOLADENS 300-T Oil Unit condensing boiler 35.4 to 53.7 kw

CONTROL PANEL. RIELLOtech PRIME ACS INSTALLATION, OPERATION AND MAINTENANCE MANUAL

Transcription:

C 153-01 CH only, oil-fired, cast iron boiler Life-enhancing heat GB

CH only, oil-fired, cast iron boiler RELIABILITY SAFETY EASY TO OPERATE EASE OF MAINTENANCE

Life-enhancing heat CAPRI R range includes twelve models of floor-standing, oil fired, CH only boilers, heat outputs from 24 to 43 kw, open chamber version (RTF) or sealed chamber version (RTFD), both are available in special configuration VA managing two different CH areas, high and low temperature. All boiler electronics are designed for connection to an external cylinder. is equipped with an oil-fired, blown air burner and cast iron heat exchanger (EN-GJL-200) with three smoke passes. The shape of the combustion chamber allows the flame to fully develop and spread toward the widest exchange surface, exposing it to the highest quantities of heat while keeping the surface thermal load low. A high-thickness insulation entirely covers the heat exchanger thus avoiding wasteful and costly heat dispersions toward the outside. The casing is made of sheet panels which are protected through electro-galvanic technology and painted with epoxy-polyester powders for the longest, trouble-free lifetime. Efficiency rating according to 92/42/EC:. VA models only The control panel includes a printed circuit board, master switch with light, boiler mode selector, domestic hot water and central heating temperature regulation selectors (also adjusting an external cylinder when installed), pressure gauge, led thermometer (which acts as diagnostic as well), overheating reset button. The control panel can also host a programmer, standard and digital with two channels (for VA models), electro-mechanical and supplied upon request (for other models), fully managing the boiler operation. Electronics allow connection to the thermoregulation control unit and to an external probe (option) for sliding temperature operation. can be operated via remote control (option) and a specific external probe is also available. CH zone boards are also available enabling management of three different temperature CH zones; external probe and/or remote control can also be installed. Available combinations of different CH temperature zone board/ remote control/ external probe: MODEL REMOTE CONTROL ZONE BOARD EXTERNAL PROBE NOTES CAPRI R NO NO 0SONDAES01 External probe to be connected to the boiler pcb CAPRI R YES NO 0KSONEST00 External probe to be connected to the remote control CAPRI R NO YES 0SONDAES01 External probe to be connected to the boiler pcb CAPRI R YES YES 0SONDAES01 External probe to be connected to the boiler pcb CAPRI R VA YES YES* 0SONDAES01* External probe to be connected to the boiler pcb CAPRI R VA NO YES* 0SONDAES01* External probe to be connected to the boiler pcb * supplied as standard

CH only, oil-fired, cast iron boiler DIMENSIONS 179,5 99 AIR INTAKE TFD VERSION 80 797 600 103,5 M M1 M2 R1 D 865-875 M CH flow R CH return M1 High temperature flow R1 High temperature return M2 Low temperature flow R2 Low temperature return F Domestic cold water inlet 648,5 F R R2 508 138 108 714 58 107 251 MODEL VA ACCESSORIES Model M R M1 R1 M2 R2 F D FLUE GAS DISCHARGE mm COMBUSTION AIR INTAKE mm RTF / RTF VA 23 G 1 G 1 G 1 G 1 G 1 G 1 G 1/2 150 -- RTF / RTF VA 33 G 1 G 1 G 1 G 1 G 1 G 1 G 1/2 150 -- RTF / RTF VA 43 G 1 G 1 G 1 G 1 G 1 G 1 G 1/2 150 -- RTFD / RTFD VA 23 G 1 G 1 G 1 G 1 G 1 G 1 G 1/2 120 80 RTFD / RTFD VA 33 G 1 G 1 G 1 G 1 G 1 G 1 G 1/2 120 80 RTFD / RTFD VA 43 G 1 G 1 G 1 G 1 G 1 G 1 G 1/2 120 80 Item Description Code Remote control 0CREMOTO02 External probe for remote control External probe for use without remote control Electronic kit for management of 3 CH zones by means of remote control. Equipped with external probe. 0KSONEST00 0SONDAES01 0CIRCSTA11 Hydraulic kit for connection to external cylinder WHPF BO 0KITSANI00 Hydraulic kit for connection to external cylinder WHPF BO (for RTFVA/RTFDVA versions) 0KITSANI01 Daily programmer kit 0KITBEST04 Weekly programmer kit 0KITBEST05

Life-enhancing heat HYDRAULIC LAYOUT: MODEL R PR: CH PUMP TS: LIMIT THERMOSTAT TA1: ROOM THERMOSTAT ZONE 1 (OPTIONAL) EXTERNAL PROBE TS TEMPERATURE PROBE HEATING UNIT PR TA 1 or ZONE 1 HIGH TEMPERATURE REMOTE CONTROL MODEL R VA PR: CH PUMP P1: HIGH TEMPERATURE PUMP P2: LOW TEMPERATURE PUMP TS: LIMIT THERMOSTAT TSM: LOW TEMPERATURE LIMIT THERMOSTAT VM: MIXING VALVE TA1: ZONE 1 ROOM THERMOSTAT (OPTION) TA2: ZONE 2 ROOM THERMOSTAT (OPTION) EXTERNAL PROBE TS TEMPERATURE PROBE HEATING UNIT PR COLLECTOR VM P1 M P2 TSM ZONE 1 HIGH TEMPERATURE TA 1 TA 2 Or REMOTE CONTROL

The manufacturer reserves the right to implement modifications without notice. MODEL CH only, oil-fired, cast iron boiler TECHNICAL DATA RTF / RTFD / RTF VA / RTFD VA 23 33 43 Efficiency rating Heat input Qn kw 26.6 36.3 47.2 Heat output Pn kw 24.0 33.0 43.0 Performance at nominal load % 90 90.9 91 Performance at reduced load (30%) % 89.7 90.7 90.7 Flue gas losses % 8.75 8.1 8.1 Casing heat losses % 1.25 1 0.9 Number of elements of heat exchanger 3 4 5 CO 2 value % 12.5 13.0 12.5 13.0 12.5 13.0 Flue gas temperature C 210 190 188 Bacharach number <1 <1 <1 Flue gas flow rate Kg/h 40.0 53.2 69.3 Combustion air flow rate m 3 /kw 2 2 2 Flue gas side load loss Pa 13 25 34 Water content l 20 24 28 Minimum CH flow rate l/h 680 950 1230 Water side load loss ( T=10K) Pa 4800 5600 6000 Casing heat loss ( T=50K) % 0.5 0.5 0.5 CH temperature adjustment C 50 82 50 82 50 82 Maximum CH working pressure bar 3 3 3 CH expansion vessel capacity l 12 12 12 Voltage/Frequency V/Hz 230/50 230/50 230/50 Power fuse A 2 2 2 Height mm 875 875 875 Width mm 600 600 600 Depth mm 800 800 800 BURNER TECHNICAL DATA MODEL 23 33 43 Fuel Oil 1.4 E. Hi=10210 Kcal/kg 20 C Nozzle brand Delavan W, Steinen Q, Danfoss S Nozzle type Usgal/h 0.56 0.85 1 Nozzle angle 60 W 60 W 60 B Oil adjustment pressure bar 11.4 12.0 12.0 Oil consumption Kg/h 2.24 ± 4% 3.06 ± 4% 3.98 ± 4% Pump depression bar > -0.4 > -0.4 > -0.4 Pre-heater W 55 55 - Fuel head adjustment Index fix fix fix FONDITAL S.p.A. 25078 VESTONE (Brescia) Italy - Via Mocenigo, 123 Tel. +39 0365 878.31 - Fax +39 0365 820.200 e mail: info@fondital.it - www.fondital.it Uff. Pub. Fondital - CTC 03 C 153-01 Giugno 2006 (2.000-06/2006) 9PCGB03C153