C 153-01 CH only, oil-fired, cast iron boiler Life-enhancing heat GB
CH only, oil-fired, cast iron boiler RELIABILITY SAFETY EASY TO OPERATE EASE OF MAINTENANCE
Life-enhancing heat CAPRI R range includes twelve models of floor-standing, oil fired, CH only boilers, heat outputs from 24 to 43 kw, open chamber version (RTF) or sealed chamber version (RTFD), both are available in special configuration VA managing two different CH areas, high and low temperature. All boiler electronics are designed for connection to an external cylinder. is equipped with an oil-fired, blown air burner and cast iron heat exchanger (EN-GJL-200) with three smoke passes. The shape of the combustion chamber allows the flame to fully develop and spread toward the widest exchange surface, exposing it to the highest quantities of heat while keeping the surface thermal load low. A high-thickness insulation entirely covers the heat exchanger thus avoiding wasteful and costly heat dispersions toward the outside. The casing is made of sheet panels which are protected through electro-galvanic technology and painted with epoxy-polyester powders for the longest, trouble-free lifetime. Efficiency rating according to 92/42/EC:. VA models only The control panel includes a printed circuit board, master switch with light, boiler mode selector, domestic hot water and central heating temperature regulation selectors (also adjusting an external cylinder when installed), pressure gauge, led thermometer (which acts as diagnostic as well), overheating reset button. The control panel can also host a programmer, standard and digital with two channels (for VA models), electro-mechanical and supplied upon request (for other models), fully managing the boiler operation. Electronics allow connection to the thermoregulation control unit and to an external probe (option) for sliding temperature operation. can be operated via remote control (option) and a specific external probe is also available. CH zone boards are also available enabling management of three different temperature CH zones; external probe and/or remote control can also be installed. Available combinations of different CH temperature zone board/ remote control/ external probe: MODEL REMOTE CONTROL ZONE BOARD EXTERNAL PROBE NOTES CAPRI R NO NO 0SONDAES01 External probe to be connected to the boiler pcb CAPRI R YES NO 0KSONEST00 External probe to be connected to the remote control CAPRI R NO YES 0SONDAES01 External probe to be connected to the boiler pcb CAPRI R YES YES 0SONDAES01 External probe to be connected to the boiler pcb CAPRI R VA YES YES* 0SONDAES01* External probe to be connected to the boiler pcb CAPRI R VA NO YES* 0SONDAES01* External probe to be connected to the boiler pcb * supplied as standard
CH only, oil-fired, cast iron boiler DIMENSIONS 179,5 99 AIR INTAKE TFD VERSION 80 797 600 103,5 M M1 M2 R1 D 865-875 M CH flow R CH return M1 High temperature flow R1 High temperature return M2 Low temperature flow R2 Low temperature return F Domestic cold water inlet 648,5 F R R2 508 138 108 714 58 107 251 MODEL VA ACCESSORIES Model M R M1 R1 M2 R2 F D FLUE GAS DISCHARGE mm COMBUSTION AIR INTAKE mm RTF / RTF VA 23 G 1 G 1 G 1 G 1 G 1 G 1 G 1/2 150 -- RTF / RTF VA 33 G 1 G 1 G 1 G 1 G 1 G 1 G 1/2 150 -- RTF / RTF VA 43 G 1 G 1 G 1 G 1 G 1 G 1 G 1/2 150 -- RTFD / RTFD VA 23 G 1 G 1 G 1 G 1 G 1 G 1 G 1/2 120 80 RTFD / RTFD VA 33 G 1 G 1 G 1 G 1 G 1 G 1 G 1/2 120 80 RTFD / RTFD VA 43 G 1 G 1 G 1 G 1 G 1 G 1 G 1/2 120 80 Item Description Code Remote control 0CREMOTO02 External probe for remote control External probe for use without remote control Electronic kit for management of 3 CH zones by means of remote control. Equipped with external probe. 0KSONEST00 0SONDAES01 0CIRCSTA11 Hydraulic kit for connection to external cylinder WHPF BO 0KITSANI00 Hydraulic kit for connection to external cylinder WHPF BO (for RTFVA/RTFDVA versions) 0KITSANI01 Daily programmer kit 0KITBEST04 Weekly programmer kit 0KITBEST05
Life-enhancing heat HYDRAULIC LAYOUT: MODEL R PR: CH PUMP TS: LIMIT THERMOSTAT TA1: ROOM THERMOSTAT ZONE 1 (OPTIONAL) EXTERNAL PROBE TS TEMPERATURE PROBE HEATING UNIT PR TA 1 or ZONE 1 HIGH TEMPERATURE REMOTE CONTROL MODEL R VA PR: CH PUMP P1: HIGH TEMPERATURE PUMP P2: LOW TEMPERATURE PUMP TS: LIMIT THERMOSTAT TSM: LOW TEMPERATURE LIMIT THERMOSTAT VM: MIXING VALVE TA1: ZONE 1 ROOM THERMOSTAT (OPTION) TA2: ZONE 2 ROOM THERMOSTAT (OPTION) EXTERNAL PROBE TS TEMPERATURE PROBE HEATING UNIT PR COLLECTOR VM P1 M P2 TSM ZONE 1 HIGH TEMPERATURE TA 1 TA 2 Or REMOTE CONTROL
The manufacturer reserves the right to implement modifications without notice. MODEL CH only, oil-fired, cast iron boiler TECHNICAL DATA RTF / RTFD / RTF VA / RTFD VA 23 33 43 Efficiency rating Heat input Qn kw 26.6 36.3 47.2 Heat output Pn kw 24.0 33.0 43.0 Performance at nominal load % 90 90.9 91 Performance at reduced load (30%) % 89.7 90.7 90.7 Flue gas losses % 8.75 8.1 8.1 Casing heat losses % 1.25 1 0.9 Number of elements of heat exchanger 3 4 5 CO 2 value % 12.5 13.0 12.5 13.0 12.5 13.0 Flue gas temperature C 210 190 188 Bacharach number <1 <1 <1 Flue gas flow rate Kg/h 40.0 53.2 69.3 Combustion air flow rate m 3 /kw 2 2 2 Flue gas side load loss Pa 13 25 34 Water content l 20 24 28 Minimum CH flow rate l/h 680 950 1230 Water side load loss ( T=10K) Pa 4800 5600 6000 Casing heat loss ( T=50K) % 0.5 0.5 0.5 CH temperature adjustment C 50 82 50 82 50 82 Maximum CH working pressure bar 3 3 3 CH expansion vessel capacity l 12 12 12 Voltage/Frequency V/Hz 230/50 230/50 230/50 Power fuse A 2 2 2 Height mm 875 875 875 Width mm 600 600 600 Depth mm 800 800 800 BURNER TECHNICAL DATA MODEL 23 33 43 Fuel Oil 1.4 E. Hi=10210 Kcal/kg 20 C Nozzle brand Delavan W, Steinen Q, Danfoss S Nozzle type Usgal/h 0.56 0.85 1 Nozzle angle 60 W 60 W 60 B Oil adjustment pressure bar 11.4 12.0 12.0 Oil consumption Kg/h 2.24 ± 4% 3.06 ± 4% 3.98 ± 4% Pump depression bar > -0.4 > -0.4 > -0.4 Pre-heater W 55 55 - Fuel head adjustment Index fix fix fix FONDITAL S.p.A. 25078 VESTONE (Brescia) Italy - Via Mocenigo, 123 Tel. +39 0365 878.31 - Fax +39 0365 820.200 e mail: info@fondital.it - www.fondital.it Uff. Pub. Fondital - CTC 03 C 153-01 Giugno 2006 (2.000-06/2006) 9PCGB03C153