IntesisBox BACnet/IP Server - Notifier ID3000 series

Similar documents
ibox Modbus Server Gateway for the integration of Notifier ID3000 / ID3002 / ID60 / ID50 fire panels in Modbus enabled monitoring and control systems

ModBus DE-1 INSTALLATION AND USER MANUAL

MiNi Server environment MoNitoriNg SySteM

APPLICATION DATA SHEET

Added password for IP setup page : Password must be in IP format!

Smart Wireless Sensor

FS Mircom FX2000 Fire Alarm Panel

ModSync Sequencing System Installation & Operation Manual. For use with Fulton Steam Boilers.

FST DFS Notifier Onyx 640

Replaceable LED modules. Sleep or unattended mode. Auto-silence and auto-acknowledge

SCC Inc. Master Panel. Specifications. Document No. TS 2010 February 11, Product Description. Sample Specification

Labkotec Ice Detector

opti-visor ultra-efficient chiller plant automation Typical specification

For Complete Fire and Gas Solutions

APPLICATION DATA SHEET

FieldServer Driver - Serial FS Notifier NCA

Engineering Guideline. pac- Carriers Type Universal

P2267 NETWORK INTERFACE

FieldServer Driver - Serial FS SBT-FSI (Siemens Building Technologies Foreign Systems Interface)

Complete packages with Software and Controller

Bosch TCU Integration Module Administrator's Guide

Fire and Gas Monitoring Panel ST7-HV

User manual. KNXpar. version

IRIS Touch Quick Installation & Maintenance Guide. Version 1.0

AUTOMATION. Operator s Manual RST Series Web Enabled Input Module. Rev. A2, 1/12

Operation Manual Fighter ProVision Software. Version: 0.0 Revision: 1

Installation Manual. ATS Remote Annunciator Catalog 5350 DANGER WARNING D

EC-BOS-602/616 AX Security

Laptop / PC Programming Manual

Fire control panels FC360

Smart Wireless Sensor

User Manual Doc.Ref : JA-KNX-UM. JA-KNX Jablotron KNX Interface ELAUSYS JA-KNX. KNX Interface for Jablotron alarm system.

NGC-40 Bridge. Modbus Overview. Raychem-AR-H58862-NGC40BridgeModbusOV-EN-1805 nvent.com 1

ACTIVE INFRARED BARRIER

Roo232 User Guide. Revision 1.0. Copyright 2006 RoboDynamics Corp

TELECOMMUNICATION. Telecommunication. Wireless Phone

Alarm Panel [ PRELIMINARY HARDWARE MANUAL ] USER MANUAL. v1.0a. May 7, 2008 D-OC-UM

TS400. Operating Manual. Test Station for Microtector II Series (G450/G460)

Milestone SMI Intrepid II Perimeter Module 1.1 User s Manual

Lift Station Level Controller

IRIS Touch 400 & 600 Range Installation Manual. Honeywell Galaxy Range. Version 2.0

X11CA COMPUTER ANNUNCIATORS

LMV51 Control. Specifications. Document No. LV February 7, Product Description. Sample Specification

PWM. Solar Charge controller with Ethernet. Solar Smart PWM 20Amp. Hardware Description : Release : 19 June 2014

Telemetry Communications Device. Installation Guide. Interface for the Emizon managed network. Issue 1: February 2008

/8 DIN Level Indicator

The Protec driver connects to the Protec Fire Detection range of digital addressable fire control panels. Available for Commander and ObSys.

600 Range Dialer Installation Manual. Version 1.0

ICC INDUSTRIAL CONTROL COMMUNICATIONS, INC.

SETTING UP A VIRTUAL KEYPAD WITH A DSC POWERSERIES ALARM SYSTEM

RF SCOUT PLUS INSTRUCTION MANUAL. Dielectric, LLC 22 Tower Rd. Raymond, ME Phone: January 2015, Rev B 1

Advanced FireAlarm Panel 1-4Loop

FCD-wire Contents. List of Figures

Master devices. Type X-AIR-ZMAS. Zone master module for up to 25 zone modules, with integral webserver and interfaces to higher-level systems

IRIS Touch Quick Installation & Maintenance Guide. Version 1.0

ATSTORM v2. The sensor with FCES technology is connected to the interface with a communication cable.

TRACENET TM GENESIS CONTROL AND MONITORING SYSTEM SPECIFICATION GUIDE

GPS or DCF 77. DTS Masterclock

User Manual Doc.Ref : EVO-KNX-UM. EVO-KNX Paradox KNX Interface ELAUSYS EVO-KNX. KNX Interface for Paradox alarm system. User Manual.

VAC PLC. System Description

User manual. KNXgal. version

IndigoVision Alarm Panel. User Guide

MULTIFUNCTIONAL SYSTEM

Optical Fiber Monitor (OFM) Whitebox WB-OFM-1262-DC

Adaptive CyCLO Technical and HMI User Guide. CyCLO User Guide. Version th December 2017 REV

The system should also be capable of recording events automatically on any compatible DVR and should be able to retrieve recordings based on events.

SAFETY/ SECURITY - FIRE FIGHTING INTEGRATED SYSTEMS

NGC-40 PANEL MOUNTED ADVANCED MODULAR HEAT-TRACING CONTROL SYSTEM HTC HTC3 PRODUCT OVERVIEW

TTSIM-1 Sensor Interface Module

Delta ORCAview 3.40 BACNET PROTOCOL IMPLEMENTATION CONFORMANCE STATEMENT

SEE DISCLAIMER ON REVERSE

ACS-30 MULTIPOINT COMMERCIAL HEAT-TRACING SYSTEM PRODUCT OVERVIEW. ACS-30 System

Gas Controller Module GC-06

NGC-40 PANEL MOUNTED ADVANCED MODULAR HEAT-TRACING CONTROL SYSTEM HTC HTC3

HERCULES 6 GRAPHICS SYSTEM

Guide for the integration with supervision systems FIRE DETECTION AND EXTINGUISHANT SYSTEMS GUIDE FOR INTEGRATION WITH SUPERVISION SYSTEMS

IRIS Touch Quick Installation & Maintenance Guide. Version 1.6

ION Meter Alerts TECHNICAL NOTE NOVEMBER In This Document

1.1 Ethernet Remote Annunciator Controller (RAC) using the up to 4 ATC-300+ connected via RS-485 to TCP/IP gateway

LMV52 Control. Specifications. Document No. LV February 3, Product Description. Sample Specification

T a b l e o f C o n t e n t s

Configuration and Operation Manual for the Unipos

Process & TeMPerATUre UniversAl input DigiTAl MeTers

Industrial Grade Gas Detection Detecting The Difference

Installation Manual GalaXy G2 / G3 / GD. o Settings GalaXy o Linking with iprotect o Keymap

ECO N DATE DESCRIPTION OF CHANGE CHG

Fire control panels FC726 FC726-XA

IRIS Touch Quick Installation & Maintenance Guide. Version 1.0

Med Touch Master Alarm

GasGard 100 Control System

Centaur TM II Cube Slave Alarm Signalling Equipment INSTALLATION GUIDE

INSTRUCTION MANUAL. AQ S254 Alarm and Indication IED

Isolated Power Systems Equipment

Metasys Integrator Compu-Aire Application

FC722 Fire control panel

Process Alarm Solutions

Flair 500 Series Annunciators

USER MANUAL FOR OPERATING SYSTEM

Laboratory Enclosed Scroll Air Compressor System with Premium NFPA Controls

RS485 MODBUS Module 8AI

Transcription:

IntesisBox Server - Notifier ID3000 series Gateway for integration of Notifier ID3000, ID3002, ID50 and ID60 fire panels into enabled control systems. Integrate your Notifier fire panels into your BACnet client device or system (SCADA, BMS, PLC, HMI, TouchPanels ). client LAN WAN INTERNET Ethernet IntesisBox RS232 Notifier ID3000 series LinkBoxBacnet Configuration Software RS232 Only needed for configuration Monitor & Control your network of Notifier fire panels remoy from your Control Center using any commercial SCADA or monitoring software with driver. IntesisBox allows communication, acting as a server, allowing polling or subscription requests (COV). IntesisBox connects to the RS232 port of the Notifier panel, either through the RS232 port of the mother board, or through the isolated ISO-RS232 port (optional card). Monitoring of the Notifier elements (detectors, outputs ) through independent BACnet objects. The value in the object indicating the state of the panel's element associated is fully configurable. Commands toward the panel are also supported (reset, silence, test elements ). Fixed BACnet object IDs mapping, the object number identifies the element into the Notifier panel. Simple configuration, no point's mapping configuration is needed, just the communication parameters (IP address, baud rate ). One full ID3000 panel capacity is supported. IntesisBox Server series are configured using LinkBoxBacnet, a software tool for windows TM which is supplied along with the purchase of IntesisBox with no additional cost. The user interface of LinkBoxBacnet allows simulating the values of the BACnet objects without the need to be physically connected to the panel, very useful while in commissioning phase. 1 / 9

Description IntesisBox Server for integration of NOTIFIER ID3000 / ID3002 / ID50 / ID60 fire panels Order Code Description IBOX-BAC-NID3000 This gateway allows integrating the Notifier panel through protocol. The gateway acts as a BACnet server device. Commands toward the panel are allowed. Immediate response, operation based on events. Main features Software for configuration and test is supplied with the gateway. Through the user interface, it is allowed to simulate the status of the BACnet objects without the need to be physically connected to the panel. Allows to be mounted on DIN rail, wall or desktop. Power from 9 to 30Vdc or 24Vac BACnet features BACnet ASHRAE 135 2001 Annex J - protocol. Parameters configurable: IP address, device instance number, port, etc. BACnet objects supported: Analog input, Analog output (present value property). Every object contains the information of a single element of the panel. Fixed object IDs mapping, the object number identifies the element. Notifier features Capacity: 1 to 8 loops (depends on the panel). Detectors: 1 to 99 per loop (depends on the panel). Modules: 1 to 99 per loop (depends on the panel). 1 to 255 zones (depends on the panel). 15 general states of the panel in independent BACnet objects. Indication of communication error with the panel. Supports protocols full/duplex (panel main board) and half/duplex (opto-isolated ISO RS232 board, recommended). Simple configuration: COM, baud rate, etc. Each detector, module and zone is offered in an independent BACnet object. The value offered per each BACnet object, according to each possible state of the panel s element associated, is configurable through a point s relation table. This allows representing different states of the element with a single value in the BACnet object, and even ignoring certain undesired states. Commands toward the panel are allowed, like reset, silence, etc for the panel and activate/deactivate elements and put them into test mode. 2 / 9

Sample applications Integration of any Notifier ID3000 series panel into BACnet control systems. client LAN WAN INTERNET Ethernet IntesisBox RS232 Notifier ID3000 series control system: Notifier ID 3000 series panels: Building Automation. SCADA. HMI TouchPanels Programmable Logic Controllers (PLC)... Detectors. Modules. Zones....... Full monitoring and control System monitoring / controlling System under supervision / control 3 / 9

Typical application Monitor & Control of a network of NOTIFIER fire panels remoy from a Control Center using any commercial SCADA or monitoring software with client driver. SCADA or BMS Supervision with LAN WAN INTERNET Ethernet RS232 4 / 9

BACnet interface of IntesisBox BACnet interface Device type BACnet protocols supported Interactivity with BACnet system Server BACnet IP, (Annex J) Point's Read/Write allowed. Subscription requests (COV) allowed. Specifications BACnet Conformance Class Supported: Class 3 Data Link Layer Option: BACnet IP, (Annex J) Segmented Requests/Responses Not Supported BACnet Standard Application Services Supported and more details are explained in BACnet IP Server KNX PICS (protocol implementation conformance statement) /pdf/intesisbox_bacnet_ip_server_nid3000_pics.pdf 5 / 9

Notifier interface of IntesisBox General features Supports protocols full/duplex (panel main board) and half/duplex (opto-isolated ISO RS232 board, recommended). Simple configuration: COM, baud rate, etc. Each detector, module and zone is offered in an independent BACnet object. Indication of communication error with the panel. The value offered per each BACnet object, according to each possible state of the element associated, is configurable. This allows representing different states of the element with a single value in the BACnet object, and even ignoring certain undesired states. Commands toward the panel are allowed (i.e. reset, silence of the panel, and activate/deactivate elements or put them into test mode). Capacity Loops: 1 to 8 (the number used will depend on the panel). Detectors: 1 to 99 per loop (the number used will depend on the panel). Modules: 1 to 99 per loop (the number used will depend on the panel). Zones: 1 to 255 (the number used will depend on the panel). 15 general states of the panel in independent BACnet objects. 6 / 9

Configuration tool LinkBoxBacnet Visual engineering tool, easy of use, for gateway s configuration and supervision compatible with Microsoft Windows operating systems, supplied with the gateway with no additional cost. Multi-window tool allowing to supervise simultaneously the communication activity with both protocols (systems), real time values for all the signals allowing to modify any value (very useful for test purposes), console window showing debug and working status messages, and configuration windows to configure all the gateway s parameters and signals. Allows configuring the gateway s parameters while in off-line (not connected to the gateway). Connection to the gateway for download the configuration and supervision by using serial COM port of the PC (serial cable supplied with the gateway). Allows configuring all the external protocols available for IntesisBox Server series. Upgrades for this software tool available free of charge whenever a new protocol is added to the IntesisBox Server series. Multi-project tool allowing having in the engineer s PC the configuration for all the sites with different IntesisBox Server series gateways. Multi-language tool, all the language-dependent strings are in a plain text file (tab separated) for easy modification or addition of new languages. A list of system commands is available to send to the gateway for debugging and adjust purposes (Reset, Date/time consultation/adjust, Firmware version request ). 7 / 9

Mechanical & Electrical characteristics Enclosure Plastic, type PC (UL 94 V-0). Dimensions: 107mm x 105mm x 58mm. Color Light Grey. RAL 7035. Power 9 to 30Vdc +/-10% 1.4W. 24Vac +/-10% 1.4VA. Plug-in terminal block for power connection (2 poles). Mounting Wall. DIN rail EN60715 TH35. Notifier port 1 x Serial RS232 (DB9 male DTE). port 1 x Ethernet 10BT RJ45. LED indicators 1 x Power. 2 x Serial port (Notifier) activity (Tx, Rx). 2 x Ethernet port link and activity (LNK, ACT). Console port RS232. DB9 female connector (DCE). Configuration Via console port. 1 Firmware Allows upgrades via console port. Operational 0 C to +70 C temperature Operational humidity Protection RoHS conformity Certifications 5% to 95%, non condensing IP20 (IEC60529). Compliant with RoHS directive (2002/95/CE). CE 1 Standard cable DB9male - DB9female 1,8 meters long is supplied with the device for connection to a PC COM port for configuring and monitoring the device. The configuration software, compatible with Windows operating systems, is also supplied. 8 / 9

Dimensions Power + Ethernet port 58 mm Notifier port Console port 107 mm 105 mm Recommended available space for its installation into a cabinet (wall or DIN rail mounting), with space enough for external connections 100 mm 130 mm 115 mm 9 / 9