VacuNest. Shape Memory Tooling. shaping the future ~ today. VacuNest is a NOVATEC technology

Similar documents
ragworm Introduction to Ragworms PCB Assembly Service Specialists in Circuit Board Assembly

Safety vacuum drying oven for flammable solvents

premium line Stations Different equipment designed for a specific soldering or rework job

VRA2000 Series Port size: Rc1/4, Rc3/8, G1/4, G3/4, 1/4NPT, 3/8NPT

Vacuum drying oven for non-flammable solvents

Key Features & Benefits w Digital display for repeatable w Automatic control of the preheater for w Easy profile creation for operator

Repair under control

VD 53 - Vacuum drying oven for non-flammable solvents

SERVICE MANUAL FOR MODEL RM-10

SMT DESOLDERING DX LONER ATMOSCOPE Self-Contained SMT Deluxe Hot Air Station, Page 22

Reliable processes with and without vacuum

QFP Carrier & Development Socket

RD-500V RD-500SV ESD SMT REWORK SYSTEM

SMD Rework Technology Complete solutions

SMD Rework Technology Complete solutions

TF 1800 and TF2800. BGA Rework Systems. Solutions and systems for soldering, rework and repair of electronics. A family-owned company since 1958

Cimco Series 21. Series 21 - Operator Instruction Manual INDEX. Description. Standard Instructions 2 to 4. Operating Control Panel 5

Mink MV. Claw Vacuum Pumps for Rough Vacuum Industrial Applications. Claw Vacuum Technology by Busch

METCAL QX2 CONVECTION REWORK SYSTEM USER GUIDE

3 3SP_O3_5 C Package

IAQ_100 C Package

NTS STRUME IN N-ON DE

3SP_H2S_50 Package

Wet and dry vacuum cleaners NT 65/2 Tact²

Accessories for WHA 3000P and WHA 3000V

SCC 61 E Valid as of E61SE0404 up to E61SE... SCC 61 E

Technical Specifications

incubator, the best in its class

110BPH for 5 gallon PET bottle automatic blowing machine

SMD Rework Station TABLE OF CONTENTS

Reasons for reissue are provided in Section 6, REVISION SUMMARY.

Reflow Soldering Guidelines

Bench Top SMT Pick & Place System

SERVICE MANUAL FOR MODEL RM-26

Vacuum drying VD VDL series

Heat Sensor Cable Alarm Units DT650L / DT950L

THERMAL VACUUM TESTS OF A FIVE WATT PSEUDO CHIP SEM-X ELECTRONIC MODULE CLAMPED IN A SATELLITE BOX

INSTALLATION INSTRUCTIONS

Di-440 The Modular Analyser

NT 35/1 Tact (110V) Multi-purpose wet & dry vacuum cleaner with Tact automatic filter clean system for heavy duty dust extraction.

Chapter 6. Do s & Don ts in Refrigeration & Air-Conditioning Servicing

WHA 3000P Hot Air Station

INSTALLATION GUIDE Induction Cooktops

SAVE THESE INSTRUCTIONS

1. STANDARD CONTINUOUS LAMINATING MACHINE FOR THE PRODUCTION OF FLAT WALL PANELS

AIR HANDLERS. Central Station (CS3) Roof Mounted (RT) (Modular AL Frame AHU)

SCC 201E Valid as of E21SE0404 up to E21SE... SCC 201E

P P Gas Fireplace. P See Thru

BINDER Scientific Product Catalog

Wet and dry vacuum cleaners NT 25/1 Ap

PRODUCT OVERVIEW. or other secondary operations using a high velocity, high impact air stream.

HOT AIR GUN MODEL NO: CHG1500D USER INSTRUCTIONS PART NO: GC0414

SonoSelect and SonoSafe energy meters

Wet and dry vacuum cleaners NT 65/2 Ap

Special vacuum cleaners NT 55/1 Tact Bs

Inverted Through Board Surface

Selective Conformal Coating

Installation Instructions. For the 18 Built-In Dishwasher and Front Color Panels

All rights for changes reserved that lead to technical improvement. kolb GmbH 2017

GASS Module. User Manual. Gas Analysis Sampling System PERMA PURE

OPERATING MANUAL FOR LF-852DII HOT-AIR S.M.D. REWORK STATION

DTA. Motor thermistor relay. Benefits. Description

TILT AND SLIDE WINDOW

Intelligent Lead Free Soldering Station OPERATION and MAINTENANCE MANUAL

HIGH QUALITY VAPOR PHASE REFLOW SOLDERING. SMTA Arizona-Sonora December 4th 2012

Wet and dry vacuum cleaners NT 48/1 (110V)

Wet and dry vacuum cleaners NT 35/1 Tact (240V)

FlowMark Model Mark-II-SC Installation Operation Manual. EPA Est.#: FL-1

Operation and Maintenance Manual for the SODRTEK ST 325 Digital Convective Soldering/Desoldering System P/N

DIOSNA Production Scale Processing Plants. VAC 150 to Mixing, Granulating and Vacuum drying.

QUICK BGA2015. Precision BGA Rework System. Features:

Digital LEAD FREE. Soldering Soldering. Temperature range. Station. N1-06 Nozzle ø0.6 N1-08 Nozzle ø0.8 N1-10 Nozzle ø1.0 N1-13 Nozzle ø1.3. ø2.

Service Instructions

NT 35/1 Tact Te. Tact system (Tact Automatic Filter Cleaning System) Ideal connections. High-quality, robust equipment.

Duct smoke housings, 4-wire D341/D341P and D342/D342P

Application Note 319. Flex Power Modules. Repair/Rework Recommendations for. Flex Power Modules

STEAM STERILIZER SERIE S1000 (RBE)

Reasons for reissue are provided in Section 6, REVISION SUMMARY. Figure 1. Figure 2

NT 45/1 Tact. NT 45/1 Tact, ,

CATALOGUE MODULAR SERIES THE STRENGH OF EXPERIENCE

Wet and dry vacuum cleaners NT 27/1

#PI1016: Rear Door Exterior Paint Finish Chipped, Cracked or Scratched Along Rear Corner of Rear Side Door Reveal Molding - (Jul 15, 2013)

SpinTron 2: 2-inch High Vacuum Magnetron Sputter Source Product Installation and Use

emitting diodes (LEDs). Special consideration

Sheet Formers "Rapid Koethen" System

DOUBLE DOOR FREEZER.

Roll Heated Flatwork Finisher

An ISO 9001 : 2008 Certified Company

WET/DRY VACUUM MODEL SV-12

Mounting Instruction

SCC 101 G Valid as of G11SE0404 up to G11SE... SCC 101 G

CEILING FAN OWNER S MANUAL

HOTCO BAND HEATERS FLEXIBLE BAND HEATERS - MICA INSULATED CONSTRUCTION AND LIMITATIONS ELECTRICAL TERMINATION WELDED BAND HEATERS - MICA INSULATED

Metal Detection. High Performance Metal Detection Delivering Efficiency and Reliability SAFELINE

COMMERCIAL ELECTRIC DRYER

Automated Production Equipment, Inc. INTRUDER LIGHTNING. SMD-7500 SMT/BGA/Chip Scale Placement and Rework System OPERATOR S MANUAL

NT 35/1 Tact. Multi-purpose wet & dry vacuum cleaner with Tact automatic filter clean system for heavy duty dust extraction.

NT 40/1 Tact. Robust bumper. Ergonomic push handle

REFRIGERATORS AND FREEZERS. laboratory chromatography ultra low temp pharmacy vaccine hazardous flammable undercounter performance qualified

Ca 6s and BCa 6s kw INSTALLATION AND OPERATING INSTRUCTIONS. Page 1 31/07/00

Transcription:

1 VacuNest Shape Memory Tooling shaping the future ~ today VacuNest is a NOVATEC technology

2 VacuNest Shape Memory Tooling shaping the future ~ today

3 PRIOR ART SOLUTIONS TECHNOLOGIES DEDICATED TOOLS FLEXIBLE PIN ARRANGEMENT TOOLS COMPLIANT TOOLS DRAWBACKS - Not flexible -Lead-time -Price - Problem with high density boards - Version changes - The support force is applied locally (components can be damaged under the joint action of the pins and the squeegee/transfer head. - Sensitive to solder paste contamination - Board flatness is not guaranteed - The support is not firm enough - The boards can be bowed upwards - Maximum component height (5 mm) VacuNest - shaping the future ~ today

4 WORKING PRINCIPLE ~ VacuNest A pliable antistatic chamber contains a foam former surrounded by polymer granules. Simply place a golden board onto the modules and press down. The chambers are profiled to the shape of the underside of the board, on activation of the vacuum this shape is now held. The shape will be held for weeks / days / months until the vacuum is released whereupon the modules return to their original shape awaiting a new set up. Outer Membrane Inner Membrane

5 WORKING PRINCIPLE ~ VacuNest Pre Shaping Shape Held by Vacuum

6 ADVANTAGES Forces Prior Art VacuNest SUPPORT PRESSURE SQUEEGEE PRESSURE SQUEEGEE PRESSURE CHIP BOARD QFP Q F P CHIP SUPPORT PRESSURE BOARD QFP VacuNest ADVANTAGES The support forces are spread over the whole board No risk damage to a component due to the pin / printing pressure Firm and precise support Ease of use If a board version changes simply reset No dedicated tooling and very short payback period

7 Modules Available Low Profile For 25mm+ tooling height Standard Vacuum set with tooling plate Module Sizes 100mm long x 40mm wide 366mm long x 40mm wide 466mm long x 40mm Wide 470mm long x 50mm wide Deflate Auto set up Vacuum connections to inner & outer chambers

LOW PROFILE & STANDARD MODULES SET UP PROCEDURE ~ Step 1 8 Min 39mm Max 159mm Quick release Vacuum links Position required number of modules ~ to suit board width ~ Low Profile Min 25.4mm ~ 39mm tooling height

LOW PROFILE & STANDARD MODULES SET UP PROCEDURE ~ Step 2 9 Set up tooling plate With board at print position, place tooling plate on conveyor rails, press down and switch vacuum ON ~ modules hold board profile

LOW PROFILE & STANDARD MODULE SET UP PROCEDURE ~ Step 3 10 Run Production Provided vacuum is held (auto regulated) the shape will be held indefinitely

DEFLATE MODULES SET UP PROCEDURE ~ STEP 1 11 A B Position required number of modules ~ to suit board size ~ 100mm long x 40mm wide 366mm long x 40mm wide 466mm long x 40mm wide 470mm long x 50mm wide A B Connect Vacuum ~ Link the Modules ~ > Inner Membrane > Outer Membrane

DEFLATE MODULES SET UP PROCEDURE ~ STEP 2 12 >> Select ~ SET UP Load PCB Board Vacuum applied to inner membrane and modules ~ DEFLATE ~

DEFLATE MODULES SET UP PROCEDURE ~ STEP 3 13 + Activate ~ rising table Modules contact underside of PCB Select ~ 0 position ( stencil should hold board flat) ( or use a Set up Plate ) Modules return to rest position conforming to underside shape

DEFLATE MODULES SET UP PROCEDURE ~ STEP 4 14 Select ~ VACUUM Run Production Underside profile is held Provided vacuum is held (auto regulated) the shape will be held indefinitely

DEFLATE MODULES SET UP PROCEDURE 15 Step 1 Step 2 Step 3 Step 4 Module at rest DEFLATE Conform to shape Vacuum Shape Memory

VacuNest ~ Parts List Modules 16 VacuNest Modules (VNM) Low Profile (LP) Standard (S) Deflate (DM) Low Profile : VNM LP (Support Length) (Support Width) (Tooling Height) VNM LP 100 40 (TH) VNM LP 366 40 (TH) VNM LP 466 40 (TH) (TH) Tooling height 25.4 ~ 39mm Maximum Underside Component 8mm Standard : VNM S (Support Length) (Support Width) (Tooling Height) VNM S 100 40 (TH) VNM S 366 40 (TH) VNM S 466 40 (TH) VNM S 470 50 (TH) (TH) Tooling height 39 ~ 159mm Maximum Underside Component 12mm Maximum Individual component 15mm Deflate : VNM DM (Support Length) (Support Width) (Tooling Height) VNM DM 100 40 (TH) [min 55mm] VNM DM 366 40 (TH) [min 39mm] VNM DM 466 40 (TH) [min 39mm] VNM DM 470 50 (TH) [min 39mm] Deflate clearance on set up 8mm Maximum Underside Component 12mm Maximum Individual Component 15mm

VacuNest ~ Parts List Controllers 17 Controllers for Low Profile / Standard Modules VNC V FS -R Vacuum ON / OFF Foot switch Connect to compressed air supply In built vacuum generation ~ regulated VNC V RS -R Vacuum ON / OFF Remote switch Connect to compressed air supply In built vacuum generation ~ regulated Controller for Deflate Modules 3 position Remote switch (SET/ 0 / VAC) Connect to compressed air supply In built vacuum generation ~ regulated VNC V RS DMV -R

VacuNest ~ Parts List Set Up Plates 18 VNSP - 450 Set up plate 450mm x 450mm with lifting handle, to ensure board is flat. For use on Printers or machines with flush over the top Board tooling clamps. VNSP 450 - R Set up plate 450mm x 450mm with lifting Handle. Complete with a set (5 pieces) of tubular strips that incorporate magnetic strips For attachment. Strips positioned between conveyor rails to flatten board where over the top tooling clamps are not flush with board surfaces ~ typically on pick & place machines. VacuNest Module Membrane Repair Service Exchange / Recovery Service: In the event of a membrane being damaged Novatec offer a return to factory refurbishment service

19 Shaping the future today.. Screen / Stencil Printers Placement Machinery VacuNest Shape Memory Tooling