WaterLeakStop Z-8. 8-Zones Water Leak Detector Expansion Unit. User Manual

Similar documents
WaterLeakStop Manual. Detection and Management of Water Leaks WLS-1

ABOUT THIS DOCUMENT AND THE DOCUMENT STRUCTURE WE USE

INSTRUCTION MANUAL T119 1MN0110 REV. 0. operates with ISO9001 certified quality system

KM300 Carbon Monoxide Detection System Installation Manual

Operating Instructions. For. Alarm Control Module. Model SSR 500

Technical Speci fications 220V AC 50Hz or 110V AC 60Hz Accessories operational voltage. 2x 12V / 7Ah sealed lead acid gel batteries

INSTRUCTION MANUAL T30 1MN0107 REV. 0. operates with ISO9001 certified quality system

MO144. Operators Guide. Universal Timer Module

PRX-320 Waterproof Proximity Access Operating Instructions and Installation Manual

WD-CS. Water leak detection cable. Technical Overview. Features. Page 1. Data Sheet Ref: Issue: 5.1.

DEB71. Earth Leakage Monitoring Relay. Benefits. Description

PD154 & PD158 VIGILANTE II ANNUNCIATORS Instruction Manual

Water Detection Controllers

Sitron s CF Line of Flow Switch Monitors

RM2S 2 module housing (sequence and phase-failure/asymmetry voltages)

1200-HCM DIN RAIL MOUNTING FIRE SYSTEM MODULE Fire Detection & Extinguishant Control A R T PATOL LIMITED SUPPLY FAULT SOUNDER

Flame detector FD 2011 / FD 2012

Operating Instructions

Model Gas Alarm Panel APPLICABILITY & EFFECTIVITY. This manual provides instructions for the following Sierra Monitor products:

DICTATOR Hold-Open Systems for Hazardous Areas

Flostop TS D7E and A8E. Operation Manual

Flopurge TS. Operation Manual

INSTALLATION INSTRUCTIONS

Honeywell ENERGY SAVINGS KIT

DIESEL ENGINE CONTROL UNIT DCU USER S MANUAL - N-2000 Lillestrøm, Norway Tel: (+47) Fax: (+47)

Lodam Compressor Protection Module. Technical manual. Version 3.0 SE-G1

CR Series Command Relays

AquiTron. AT-LDM Liquid Detection Module INSTALLATION INSTRUCTIONS

Model 4880 Status Output Display Module Manual

Temperature Controllers

GRADESHIFT UDL INSTRUCTION MANUAL 2.5 APPENDIX

PDD-8PCI. Power Distribution Board With Supervised Interface. Installation and Specifications Manual

Product Manual. TZ Analog Sensors. TZ Sensors 8115CF 8116CF 8117CF 8118CF. Date: January 2015 Document Number: _B

Bulletin 1608N MiniDySC Dynamic Sag Corrector

FEC403EN Installation Manual

Flush Mount SIP Access Control Intercom with Relay Installer s Guide

isopv and AGH-PV Ground Fault Detector for Ungrounded Solar Arrays up to 1100 V And Isolation Tester Prior to Array Startup (Grounded and Ungrounded)

E DATA SHEET

AZSG10000/AZSG10005/AZSG10010 ABUS Wired Outdoor Siren

Operating Instructions

PRX-320 Waterproof Proximity Access Operating Instructions and Installation Manual

Model Number Structure

Gas Safety Products. Installation, operating and maintenance. Merlin 1000S+i Gas & Electric Utility Controller. Rev: 03 Date:

DATASHEET. Burner control unit FDA 601x

Booster Power Supply Manual

INSTALLATION INSTRUCTIONS

General Purpose IO Technical Manual

ACM8 & ACM8CB. Access Power Controllers Installation Guide. - Fused Outputs - Fused Outputs. - PTC Outputs - PTC Outputs. Models Include: Rev.

MTRA-FSP Level Control Relay. Installation & Operation Manual

ROYCE SUSPENDED SOLIDS SYSTEM MODEL 7011A AND SENSORS MODELS 72A, 72P, 73B, 74A, 75A & 76A

Control and Indicating Equipment

Operating instructions DVC-P / Bedienungsanleitung Druckregler DVC-P

Installation Guide & User Manual

NATIONAL CONTROL DEVICES MirC Wireless Quick Start Guide

Ethernet General Purpose

Instructions for the fan motor control system with integrated wiring terminals SILVER C

Revision November 2013 JVA Technologies. Ethernet General Purpose IO Technical Manual

Temporary wireless battery operated fire system from Channel Safety Systems

ACM8 Series UL Listed Sub-Assembly Access Power Controllers. Installation Guide. ACM8 - Eight (8) Fuse Protected Outputs

Installation Guide for AL600ULM. Multi-Output Access Control Power Supply Charger. Rev

S304 and S305 Dust Emission Monitors. User Manual. Distributor

Water Leak Detector - Four Zone with open/short-circuit detection. Product overview

Premier External TD. Installation Manual INS352-3

Dual Technology Wall Mounted Occupancy Sensor. Manual & Specification

M2500 Engine Controller Installation Manual

ACM4 Series UL Listed Sub-Assembly Access Power Controllers

Matrix2000. User Guide - CPD Advanced Analog Fire Alarm Control Panel 4 24 Zones. Version: 2.0 Revision: 1

TECHNICAL DATA. Humidity: 85% Relative Humidity (non-condensing) at 90 F (32 C) maximum.

FireSystem 2000 Commercial and Light Industrial Fire Alarm Control Panel

isopv425 and AGH420 Ground Fault Detector for Ungrounded Solar Arrays < 100 kw And Isolation Tester Prior to Array Startup (Grounded and Ungrounded)

Gas Safety Products. Installation, operating and maintenance. Merlin 1000BH Gas Proving/Gas Detection System

DESCRIPTIVE AND INSTALLATION INSTRUCTION MANUAL FOR MODEL G1000 AND H1000 SERIES ANNUNCIATORS

APPLICATION DATA SHEET

MODEL EUR -5A AUTOMATIC SNOW/ICE MELTING SYSTEM CONTROL PANEL

INSTRUCTION MANUAL & 8200 Monitor. Manual Issue 06

Gas cylinder scale Model GCS-1

Gas Safety Products. Installation, operating and maintenance. Merlin Gas Detectors. Merlin Gas Detectors. Rev: 09 Date: Product Data Sheet

Door Release Power Supply

INSTALLATION INSTRUCTIONS

Safety Temperature Limiter STL 50 Certified to DIN EN (replaces DIN 3440)

Quickheat 30 weather compensated boiler control

INPUT / OUTPUT MINI MODULES

Commercial and Light Industrial Fire Alarm Control Panel

Specification/ Data Sheet

AL400ULACM AL600ULACM - 4 amp - 12VDC or 6 amp. - Fused Outputs - Fused Outputs

PLEASE READ THE USER GUIDE CAREFULLY BEFORE INSTALLATION AND RETAIN FOR FUTURE USE.

DTM Distributed Transmitter-Monitor

Installation Guide for models:

Isco 3700ZR Sampler. Manual Set

Emotron M10 Shaft Power Monitor. Instruction manual English

MODEL B2 INSTALLATION MANUAL

Emotron DCM Control Unit

IGD.CO.UK

ABLOY DA460 SWING DOOR OPERATOR. Installation and commissioning manual

Line Isolation Monitor (LIM) LIM2000plus

Model 3300 Technical Support and Installation Manual

TECHNICAL DATA OBSOLETE

PS6 SERIES. Installation PS6 SERIES. Power Supplies c/w Fire Panel Interface, EOL Trigger and Standby Power Option

Input module, input/output modules

FIREFLY II PLUS RELEASE DEVICES INSTALLATION MANUAL

Transcription:

WaterLeakStop Z-8 8-Zones Water Leak Detector Expansion Unit User Manual

Table of contents BRIEF DESCRIPTION... 3 SPECIFICATIONS:... 3 CONNECTIONS:... 3 PICTURES - TABLES:... 4 Figure 1 -Front Panel... 4 Figure 2 Connection Terminals... 4 DESCRIPTION OF THE LED INDICATORS... 5 CONNECTION TERMINALS DESCRIPTION... 5 CONNECTION AND COMMISSIONING... 6 SENSORS CONNECTION... 6 INTERFACE WITH WATERLEAKSTOP WLS-1... 6 CONNECTION OF RELAY CONTACTS... 6 POWER SUPPLY... 6 Connection diagram... 7 FUNCTIONAL DESCRIPTION... 8 TABLE OF ZONES... 9 ALTERNATIVE MANAGEMENT OF WASTE ELECTRICAL AND ELECTRONIC EQUIPMENT... 11 Warnings: The information contained in this document may change without notice. All rights reserved. Reproduction, adaptation or translation of this material, without the prior written permission of the manufacturer, except as permitted by the copyright laws. The manufacturer will not be responsible for any technical errors, editorial errors or omissions in this. Σελίδα 2

Brief description Specifications: Input Voltage: Current (monitoring / max): 12 V DC 8,2 / 60 ma Relay contacts(rated Voltage / Ampere): 250VAC / 12A Dimensions: 106 x 86 x 58 χιλ. (L x W x H) Weight: Mounting: 180 grams. M-36 DIN-rail (EN50022) Connections: Detection Zones Z_(1-8): The following types of sensors can be connected to detect water leakage: Pins detection, detection cable and other sensors for this reason. In zones, can be connected N.O. type sensors (Open Contact when is dry). Interface with WLS-1: Interface with one or two cable. Goto Connection Terminal Description and the corresponding terminal. Leakage management: One SPDT relay, for connection with a solenoid valve to stop the water supply or to connect a siren, an alarm system or any other notification system. Power Supply: To power the device is necessary to use stabilized power supply with an output voltage of 12VDC and minimum output current of 100mA. Σελίδα 3

Pictures - Tables: Figure 1 -Front Panel +Ζ_1 -Ζ_1 +Ζ_2 -Ζ_2 +Ζ_3 -Ζ_3 +Ζ_4 -Ζ_4 +Ζ_5 -Ζ_5 +Ζ_6 -Ζ_6 +Ζ_7 -Ζ_7 +Ζ_8 -Ζ_8 NO NC COM IN OUT (-) (+) Ζ-8 Figure 1 Connection Terminals Σελίδα 4

Description of the LED indicators ZONE 1 to 8: Continuous On: Presence of moisture Off: No presence of moisture POWER ON: Continuous On: Power On Off: Power Off RELAY ON: Continuous On: Relay On. COM - NO Off: Relay Off. COM - NC Connection terminals description Z_(1-8): In zones Z_1 - Z_8, are connected the humidity sensors. The connected sensors must have Normal Open (N.O.) terminals when they are in normal mode (no water at their probes) We pay attention, if the sensors that will be connected, have polarity. All the zones have the sequence (+) (-) from left to right. IN, OUT: Terminals interconnect with the central unit WaterLeakStop WLS-1. IN +WL PRB* OUT WL PRB *If a common power supply give energy both to the Z-8 and WLS-1, it is not necessary the connection between the IN +WL PRB. N.O., N.C., COM: Relay contacts for driving an alarm system, a communication system or a local alarm. (-), (+) DC INPUT: Power supply connection terminals. 12 V DC / 100 ma (ελάχιστο). Σελίδα 5

Connection and Commissioning Sensors connection Connect in parallel the desired sensor number, in each zone, while leaving blank the zones that will not be used. We pay attention, if the sensors that will be connected, have polarity. All the zones have the sequence (+) (-) from left to right. Interface with WaterLeakStop WLS-1 If we have the WaterLeakStop WLS1 unit, then we connect between the following points. IN +WL PRB* OUT WL PRB *If a common power supply give energy both to the Z-8 and WLS-1, it is not necessary the connection between the IN and +WL PRB. Connection of relay contacts If we want to make use of the SPDT relay, to activate other devices or circuits, we will make use of terminals N.O., N.C., COM. Relay On: When one of the zones are triggered, the terminals COM N.O., are connected. Relay Off: When all the zones are secured, the terminals COM N.C., are connected. Power supply To power the device requires a stabilized power supply with an output voltage of 12VDC and minimum output current of 100mA. Σελίδα 6

Connection diagram Σελίδα 7

Functional description The device WaterLeakStop Z-8, detects water leakages in selected locations of the monitored sites, using water sensors. The sensors are placed in each of the eight (8) available zones. In each zone, can be connected more than one sensors, connected in parallel. If a zone triggered by a sensor, will cause the state change of the relay's contacts COM, N.C. and N.O.. Also, will change the voltage level of the OUT terminal. The relay terminals may be used for: 1. trigger a siren, an alarm system or any other notification system. 2. the control of a solenoid valve to stop the water supply. The OUT terminal may be used for the interconnection between the Z-8 and the WLS-1 main unit. Restoration of COM, N.C., N.O. and OUT, comes when all zones returned to an open circuit state. Σελίδα 8

Table of Zones Α/Α 1 2 3 4 5 6 7 8 Description Σελίδα 9

Σελίδα 10

Alternative management of waste electrical and electronic equipment For the countries of the European Union This label is affixed to the product to remind you that the electrical and electronic products must not in any event be considered municipal waste. Electrical and electronic products, including cables, plugs and accessories should be separated at source, to allow the necessary treatment, with the ultimate goal to reuse or recovery. These products should be available in specified units with the best techniques of collection, treatment and alternative management. The separate treatment provides the following significant advantages: valuable materials can be reused and thus prevent the generation of municipal waste. This action helps to protect the environment and human health. Please be aware that fine may be imposed for illegal disposal of electrical and electronic equipment. Please drop your old electronic equipment at appropriate recycling electronics or contact your local authorities for further information. For countries outside the European Union The management of electric and electronic equipment in countries outside the European Union should be in accordance with local regulations. Please contact your local authorities for further information. The manufacturer Christos N. Chiotis, with contacts details: Address: Rodou 24 Koridallos, 18120, Attiki Greece Phone/Fax: 210-2018328 - Email: support@waterleakstop.com Declares that this device Ζ-8, meets the requirements of European Directives: 2004/108/ΕΚ (EMC), 2011/65/ΕΕ (RoHS). Σελίδα 11

# 240117-GR www.waterleakstop.com Σελίδα 12