LED Emergency Battery Backup

Similar documents
LED Emergency Battery Backup Installation Instructions Ordering Code: EB23UQ

1 x4 Dimmable LED RetroFits

Installation Instructions

Installation Instructions

LED Flat Panel Retrofit

I-320 SERIES AC EMERGENCY LIGHTING EQUIPMENT

INSTALLATION INSTRUCTIONS

MODEL RLY-DIM-D INSTALLATION INSTRUCTIONS

MODEL LUT-ATS-D (EPC-D-F-ATS) INSTALLATION ! IMPORTANT SAFEGUARDS!

CDL8 LED Architectural

Cold Door 2 LED Retrofit Kit Lighting System

Dioluce Products Installation Instructions

MODEL EPC-D-F-ATS INSTALLATION INSTRUCTIONS ! IMPORTANT SAFEGUARDS!

Albeo TM LED Luminaire Accessory (Emergency Battery Backup Module)

Do not make or alter any open holes in an enclosure of wiring or electrical components during kit installation.

BACKUP BATTERY INSTALLATION INSTRUCTIONS

MaxLite LED High Bay Fixtures

SERVICE BY QUALIFIED PERSONNEL ONLY

MaxLite LED Round Pendant Highbay Series

INSTALLATION INSTRUCTIONS - POWER SENTRY CONTROL POWER SENTRY CONTROL UNIT PSBCEB2 INSTALLATION INSTRUCTIONS

Installation Instructions

Cold Deck Canopy and Shelf Lights and Retrofit Kit

Bdl60u Fluorescent Emergency Ballast

FHSAC1-UNV-40L INSTALLATION INSTRUCTIONS

ESRB and ESRN Installation & Safety Instructions

INSTALLATION INSTRUCTIONS

1 General Description

ILB-CP TBTS B MOUNTING DESIGN EMERGENCY LIGHTING EQUIPMENT FOR LED Patented. See iotaengineering.com/patents for more details

Cold Deck FIT. Canopy and Shelf Lights and Retrofit Kit. Installation Guide for General Information. Tools and Accessories Recommended

DHL-LP-LED Low Profile LED Linear High/Low Bay

IMPORTANT SAFEGUARDS READ AND FOLLOW ALL SAFETY INSTRUCTIONS. HZM-Series-Class I, Div 2 Battery Unit. Instalation instructions

INSTALLATION INSTRUCTIONS - PS1055LCP & PS1555LCP LED EMERGENCY DRIVER PS1055LCP & PS1555LCP

INSTRUCTION MANUAL IMPORTANT SAFEGUARDS. When using electrical equipment, basic safety precautions should always be followed, including the following:

MaxLite 4, 6, 8 & 9 LED Architectural & Commercial Downlights

RAZOR RZR SERIES DIE CAST ALUMINUM LED EXIT SIGNS INSTALLATION AND OPERATING INSTRUCTIONS IMPORTANT SAFEGUARDS READ AND FOLLOW ALL SAFETY INSTRUCTIONS

SAVE THESE INSTRUCTIONS FOR FUTURE REFERENCE

ILB-CP TBTS A MOUNTING DESIGN EMERGENCY LIGHTING EQUIPMENT FOR LED

ARTEMIS Series of Low Occupancy LED Ceiling Mounted Fixtures (Including Stairwells) Installation & Operation Guide

IMPORTANT SAFEGUARDS READ AND FOLLOW ALL SAFETY INSTRUCTIONS. 3LERHZ Series Class I, Div 2 Combo Unit. Installation instructions

USER GUIDE & INSTALLATION INSTRUCTIONS

GTD20A Installation Instructions BRANCH CIRCUIT TRANSFER SWITCH/LIGHTING CONTROL DEVICE

ILB-CP TBTS A MOUNTING DESIGN EMERGENCY LIGHTING EQUIPMENT FOR LED

HighLINER 2. General Information: FOR YOUR SAFETY. Installation Guide for C1I75, L1C1I75, C2I75, L135C2I75

Honeywell Durafit LED Retrofit Kit

CCS-100. Installation Manual

Installation Instructions

LED IMPORTANT SAFETY INSTRUCTIONS

MaxLite Polygon Linear LED Light

MAXLITE RKT LED Retrofit Kit

IMPORTANT SAFETY INSTRUCTIONS:

Fluid Round Large 700 FMFLDRL_

2018 PRODUCT CATALOG INNOVATION. SIMPLIFIED.

Electric Fireplace. Electric Fireplace

MLLG-DE-LED-CHAN Installation Guide IMPORTANT SAFETY INSTRUCTIONS

Fillmore Small Pendant Assembly and Installation Instructions

Manifold Installation Controller MIC-180. Installation and Operation Instructions

IMPORTANT SAFETY INSTRUCTIONS:

E2 Indirect/Direct Linear Recycling Luminaire Disassembly Instructions

MANUFACTURED IN THE UK

USER GUIDE & INSTALLATION INSTRUCTIONS

PME. Series Enclosures. Battery Enclosure (BE) Field Upgrade Installation Instructions. Effective: January, Alpha Technologies

Basic Specifications to Install Tresco Lights Basic Specifications to Install Tresco Lights With With a HArDWIre a HARDWIRE To turn all s on/off at th

Innovative Lighting R-Series Overhead LED Conversion Kits

Dimmable LED Retrofit Kit

Ceiling Fan Installation Instructions

SAVE THESE INSTRUCTIONS INSTALLATION INSTRUCTIONS EMERGENCY FLUORESCENT BATTERY PACK MODEL PS300, PS600, PS1400

Installation guide. Philips EvoKit LED 2x4 and 2x2

PARTS & ACCESSORIES INSTALLATION AND SAFETY INSTRCUTIONS ITEM NO.:60010BZGTGLD SAFETY PRECAUTION. Canopy. Downrod. Housing. Transmitter CR2032/3V

installation and operation manual for Hunter Ceiling Fans

TSLED STAIRWELL INSTALLATION INSTRUCTIONS

Half Inch Round LED Rope Light

JBS-100-EC Electronic controller replacement kit for JBS-100-ECP-A and JBS-100-ECW-A Installation Instructions

Innovative Lighting R-Series Vertical Refrigeration

3MAVR60XXD Series Fan. Owner s Guide and Installation Manual. CUL Model NO. : 3MAVR60XXD

Innovative Lighting R-Series Horizontal Case Canopy LED Conversion Kits

Intensity Level. Intensity Control. Mounting Plate. Signal Type Switch Signal Ports USB DC Power Port

72 ONYX XL FLAT PANEL ELECTRIC FIREPLACE

Operation Manual Model: Light Switch Combo Universal Dimmer Module Item No.: WMR-252. Specification. Wiring

Operating Instructions

3SKYR56XXD Series Fan. Owner s Guide and Installation Manual. ETL Model NO. : 3SKYR56(XXXXX)

IMPORTANT SAFEGUARDS READ AND FOLLOW ALL SAFETY INSTRUCTIONS SAVE THESE INSTRUCTIONS. NXM Series - Survive-All. Emergency Light Unit

3AVOR56XXD Series Fan. Owner s Guide and Installation Manual. ETL Model NO. : 3AVOR56XXXXX

Innovative Lighting Smooth Light Recessed Luminaires

CEILING FAN OWNER'S MANUAL

THINLINE TL2 SERIES INSTALLATION AND OPERATING INSTRUCTIONS

CEILING FAN OWNER S MANUAL

LED CEILING LIGHT WITH MOTION SENSOR AND REMOTE. ITM. / ART Model: LM56123 CARE & USE INSTRUCTIONS

CEILING FAN OWNER'S MANUAL

Install the Fixture using a Stake (Pathway Models Only) Prepare the Fixture. Pathway and Bollards INSTALLATION OPTIONS: Installation Instructions for

ELECTRIC FLAT PANEL FIREPLACE HEATER

MaxLite LED Vapor Tight Linear Fixture

Z-800II / Z-1000II / Z-1020 Fog Machine User Manual

INSTALLATION AND OPERATING INSTRUCTIONS. For Reliance Controls Emergency Power Transfer Switch Kit Model Number 30216BRK

Integrated Ventilation System

SECTION (16140) - WIRING DEVICES

MILLA ELECTRIC FIREPLACE

IMPORTANT INSTRUCTIONS - OPERATING MANUAL

INSTALLATION INSTRUCTION for ceiling fan

CEILING FAN OWNER'S MANUAL

14PRR62XXD Series Fan. Owner s Guide and Installation Manual. ETL Model NO. : 14PRR62(X)

Transcription:

LED Emergency Battery Backup Installation Instructions Ordering Code: PLEASE READ THESE INSTRUCTIONS BEFORE INSTALLATION: TROFFER INSTALLATION STRIP INSTALLATION

INTRODUCTION & TABLE OF CONTENTS Ordering Code : (23W 120-277V QC WH) is compatible with all Litetronics 0-10V dimmable Retrofits. It is also usable with Litetronics non-dimmable Retrofits up to 23 Watts. Congratulations on the purchase of your Emergency Battery Backup. It is usable for a range of installations. We have included some of the most common ones here. Section 1- TROFFER OR WRAP INSTALL 4 Section 2- STRIP FIXTURE INSTALL 7 Section 3- MISCELLANEOUS OPERATING INSTRUCTIONS 10 Section 4- WIRING DIAGRAM A (For 0-10V LED Retrofit with dimmer) 11 WIRING DIAGRAM B (For 0-10V LED Retrofit with or without switch and without dimmer) 12 WIRING DIAGRAM C (For non-dim LED Retrofit <23W with or without switch) 13 SAFETY INSTRUCTIONS AND WARNINGS WHEN USING ELECTRICAL EQUIPMENT, BASIC SAFETY PRECAUTIONS SHOULD ALWAYS BE OBSERVED INCLUDING THE FOLLOWING: READ AND FOLLOW ALL SAFETY INSTRUCTIONS. Do not use outdoors. Do not let power supply cords touch hot surfaces. Do not mount near gas or electric heaters. Use caution when servicing batteries. Battery acid can cause burns to skin and eyes. If acid is spilled on skin or in eyes, flush acid with fresh water and contact a physician immediately. Equipment should be mounted in locations and at heights where it will not readily be subjected to tampering by unauthorized personnel. The use of accessory equipment not recommended by the manufacturer may cause an unsafe condition. Do not use this equipment for other than intended use. Installation should be in accordance with NEC and any relevant local codes. Risk of fire or electric shock. Emergency Battery Backup installation requires knowledge of electrical system. If not qualified, do not attempt installation. Contact a qualified electrician. Risk of fire or electric shock. Luminaire wiring and electrical parts may be damaged when drilling for installation of Emergency Battery Backup. Check for enclosed wiring and components. This Emergency Battery Backup shall only be installed into an UL/CUL Listed Luminaire with a steel enclosure. DO NOT INSTALL THIS EMER- GENCY BATTERY BACKUP INTO LUMINAIRES WITH NON-FERROUS METAL OR POLYMERIC ENCLOSURES To prevent wiring damage or abrasion, do not expose wiring to edges of sheet metal or other sharp objects. Voltage could be present in Battery. To prevent high voltage from being present on output leads, Battery connector must be open. Do not connect Battery connector until installation is complete. Make sure that the necessary branch circuit wiring is available. An un-interrupted AC source of power is required. THIS PRODUCT CONTAINS A RECHARGEABLE Ni-MH BATTERY. THE BATTERY MUST BE RECYCLED OR DISPOSED OF PROPERLY. In all installations, with or without a dimmer, the wires labeled 0-10V Retrofit or Luminaire must be connected to the Retrofit or Luminaire 0-10V wires before power is restored. DISCONNECT SAFETY INSTRUCTIONS Improperly installed electrical wiring can be dangerous and cause electrical fires. This product must be used in accordance with the current rating and wire sizes listed. Consult local building code before doing any electrical work. COPPER to COPPER ONLY. Do not use on Aluminum. Temperature rating: 105 C (221 F) maximum. Flame Rated UL94V-0. Can be used with and without a switch. Battery is replaceable with Litetronics s ordering code EBA45-12V. Contact the manufacturer for information on replacement battery. Easy front access to Dip Switch for adjustments to control output power of 23 watts for 0-10V to various LED retrofit models Compatible with non-dimmable LED Retrofit 120V-277V up to 23W with full power light output. Do not use with non-dimmable 32W or 50W or more than 23W LED retrofit. SAVE THESE INSTRUCTIONS 2

12 13 RETROFIT COMPATABILITY TABLE is compatible with all Litetronics 0-10V dimmable Retrofits. It is also usable with Litetronics non-dimmable Retrofits up to 23 Watts. DIMMABLE ORDERING CODE DESCRIPTION WATTS RF50UQT4XXDL 0-10V 50W 3-2x4 LED RF QC 50W RF32UQT4XXDL 0-10V 32W 2-2x4 LED RF QC 32W RF32UQT1XXDL 0-10V 32W 2-1X4 LED RF QC 32W RF32UQT2XXDL 0-10V 32W 3-2X2 LED RF QC 32W RF16UQT1XXDL 0-10V 16W 1-1X4 LED RF QC 16W RF16UQT1XXCDL 0-10V 16W 1-1X4 LED RF 16W (2) RF32UQT1XXCDL (2) 0-10V 32W 2-1X4 LED RF QC 64W (2) RF16UQT1XXCDL (2) 0-10V 16W 1-1X4 LED RF QC 32W RF32UQT1XXCDL 0-10V 32W 2-1X4 LED RF QC 32W RF32UHT1XXDL 0-10V 32W 2-1X4 LED RF QC 32W NON-DIMMABLE ORDERING CODE DESCRIPTION WATTS RF16UQT1XXC 16W 1-1X4 LED RF QC 16W RF22UQT2XX 22W 2-2X2 LED RF QC 22W What comes in the box: To Switch Line (1) Female Quick Disconnect (Attached to Male End) (1) Male Quick Disconnect (Attached to Female End) 0-10V Retrofit or Luminaire (Note: Dimmer connection wires are inside box) (2) Self-tapping screws, #8 x 1/2 Green Light Indicator Emergency Battery Backup with Magnets Test Switch (5)Wire Nuts AVAILABLE ACCESSORIES Emergency battery backup from Litetronics comes with a rechargeable battery installed. Replacement batteries are also available for purchase. Battery accessory (EBA45-12V) 3

Section 1 TROFFER FIXTURE INSTALL 1. Turn off power at circuit breaker. Open the cover of the existing fixture. 2. Remove lid of emergency battery backup by unscrewing 2 screws. 3. Check the corresponding LED RetroFit model number. Use below table to select and change dip switch position for setup. In factory default setting, Position 2 set to ON. You should set all dip switch positions to OFF, unless a position is specified as ON for your Retrofit model. DIP SWITCH SETUP FOR LITETRONICS RETROFIT MODEL NUMBER EMERGENCY OUTPUT WATTS DIP SWITCH POSITION 1 2 3 4 5 6 RF16UQT1XXC 16W RF22UQT2XX 22W RF16UQT1XXDL 16W RF16UQT1XXCDL 16W (2) RF16UQT1XXCDL 23W ON RF32UQT1XXDL 23W ON RF32UQT1XXCDL 23W ON (2) RF32UQT1XXCDL 23W ON RF32UHT1XXDL 23W ON RF32UQT2XXDL 23W ON RF32UQT4XXDL 23W ON RF50UQT4XXDL 23W ON CAUTION:IF DIP SWITCH IS MIS-CONFIGURED, i) Damage to the emergency battery backup will occur. ii) Backup battery time will be less than 90 minutes and brightness will be less than specified. 4

Section 1 TROFFER FIXTURE INSTALL 4. Place emergency battery backup on fixture and position as needed. Recommended placement is close to the junction box of LED RetroFit and input power wires. 5. Unscrew junction box cover of existing RetroFit from luminaire troffer. 6. For electrical connections, refer to the wiring diagrams on pages 11,12 and 13. Note: In all installations, with or without a dimmer, the jacketed wires labeled 0-10V Retrofit or Luminaire must be connected to the Retrofit or luminaire 0-10V dimmer control wires before power is restored. 7. Secure emergency battery backup with two of the selftapping screws provided. The holes are located inside on the bottom frame of case. 8. Connect halves of white multi-pin battery connector together. 5

Section 1 TROFFER FIXTURE INSTALL 9. Replace lid back on of emergency battery backup and secure with 2 screws. 10. Replace junction box (from step 4) over remaining wires, and secure with screws. 11. Close the cover, restore the power. 6

Section 2 STRIP FIXTURE INSTALL 1. Turn off power at the circuit breaker. Open the cover of the existing fixture. 2. Remove lid of emergency battery backup by unscrewing 2 screws. You will not need to replace the cover for this installation. 3. Remove push button tester and LED indicator with LED holder from their positions in the metal box wall. 4. Place emergency battery backup in strip fixture and position as needed. Recommended to place close to the LED RetroFit and input power wires. Extend wires for push button tester and LED indicator from unit. Mark position for emergency battery backup and holes in strip fixture wall. Remove backup. 5. Drill two holes in strip fixture wall for the LED indicator light 1/4 (6.3mm) and push button tester 9/32 (7.2mm). Replace emergency backup kit. 7

Section 2 STRIP FIXTURE INSTALL 6. Insert the LED indicator light through hole in the side of strip and secure with LED holder. 7. Insert the push button tester through hole in the side of strip. Secure with lock washer and nut. 8. Check the corresponding LED RetroFit model number. Use below table to select and change dip switch position for setup. In factory default setting, Position 2 set to ON. You should set all dip switch positions to OFF, unless a position is specified as ON for your Retrofit model. DIP SWITCH SETUP FOR LITETRONICS RETROFIT MODEL NUMBER EMERGENCY OUTPUT WATTS DIP SWITCH POSITION 1 2 3 4 5 6 RF16UQT1XXC 16W RF22UQT2XX 22W RF16UQT1XXDL 16W RF16UQT1XXCDL 16W (2) RF16UQT1XXCDL 23W ON RF32UQT1XXDL 23W ON RF32UQT1XXCDL 23W ON (2) RF32UQT1XXCDL 23W ON RF32UHT1XXDL 23W ON RF32UQT2XXDL 23W ON RF32UQT4XXDL 23W ON RF50UQT4XXDL 23W ON CAUTION:IF DIP SWITCH IS MIS-CONFIGURED, i) Damage to the emergency battery backup will occur. ii) Backup battery time will be less than 90 minutes and brightness will be less than specified. 8

Section 2 STRIP FIXTURE INSTALL 9. Secure emergency battery backup to strip fixture with two of the self-tapping screws. The holes are located inside on the bottom frame of case. 10. For electrical connections, refer to the wiring diagrams on pages 11,12 and 13. Note: In all installations, with or without a dimmer, the jacketed wires labeled 0-10V Retrofit or Luminaire must be connected to the Retrofit or luminaire 0-10V dimmer control wires before power is restored. 11. Connect halves of white multi-pin battery connector together. 12. You do not need to replace the cover on the emergency backup. The strip fixture cover is all that is required. 13. Close the cover, restore the power. 9

ion 2 Section 3 MISCELLANEOUS OPERATING INSTRUCTIONS TEST/OPERATION: 1. When AC power is applied, charge indicator light illuminates green. That indicates the battery is charging. 2. Press button PUSH to TEST for 3 seconds to simulate power failure and confirm LED RetroFit is functioning in emergency mode. Charge indicator light will be off. 3. When power fails, the emergency battery backup automatically switches to emergency power. The charge indicator light is off and the RetroFit will operate at about 23W. 4. When AC power is restored, the emergency battery automatically returns to charge mode. 5. must be charged for 24 hours before 90 minute test can be completed. MAINTENANCE: Although no routine maintenance is required to keep the emergency battery backup functional, it should be checked periodically to ensure that it is working. The following schedule is recommended: 1. Visually inspect the charge indicator light monthly. It should be illuminated. 2. Test the emergency operation of the fixture at 30-day intervals for a minimum of 30 seconds. 3. Conduct a 90-minute discharge test once a year. LED tubes should operate at about 23W for at least 90 minutes. SERVICE: Should be performed as indicated above by qualified personnel. 10

Section 4 WIRING DIAGRAM A 0-10V LED Retrofit with dimmer. Connect wires as outlined. Follow wiring diagram A below: a. Connect purple (+) and gray(-) coming out of emergency backup to purple (+) and gray (-) from LED RetroFit using wire nuts. b. Connect yellow (+) and gray(-) wires wrapped in emergency backup to purple (+) and gray (-) from LED dimmer using wire nuts. c. Plug Out-N (white) and Out-L (black/white) of emergency backup connector with LED RetroFit together. d. Connect AC-N (white) and AC-L (black) of emergency backup to un-interrupted power supply wires. e. Connect SW (red) coming out of emergency backup to dimmer. AC-N / AC-L / SW 0-10V Retrofit or Luminaire Dim (+) / Retrofit or Luminaire Dim (-) OUT-N / OUT-L NOTE: 0-10V dimmer wires inside A. 0-10V LED RETROFIT WITH DIMMER LINE (HOT) NEUTRAL WHITE HOT UNINTERRUPTED BLACK RED AC-N AC-L SW # 0-10V DIMMER YELLOW GRAY PURPLE GRAY 0-10V DIMMER (+) 0-10V DIMMER 0-10V DIMMER (-) WIRES INSIDE 0-10V RETROFIT OR LUMINAIRE DIM (+) 0-10V RETROFIT OR LUMINAIRE DIM (-) LED EMERGENCY BATTERY BACKUP WHITE BLACK/WHITE OUT-N OUT-L LED RETROFIT (0-10V) # FOLLOW DIMMER INSTRUCTION MANUAL FOR CONNECTION 11

Section 4 WIRING DIAGRAM B 0-10V LED Retrofit with switch and without dimmer. Connect wires as outlined. Follow wiring diagram B(i) below: a. Connect purple (+) and gray(-) coming out of emergency backup to purple (+) and gray (-) from LED RetroFit using wire nuts. b. Cover the yellow (+) and gray (-) coming out of emergency backup with wire nuts. c. Plug Out-N (white) and Out-L (black/white) of emergency backup connector together with LED RetroFit. d. Connect AC-N (white) and AC-L (black) of emergency backup to un-interrupted power supply wires. e. Connect SW (red) coming out of emergency backup to switch. 0-10V LED Retrofit without switch and without dimmer. Connect wires as outlined. Follow wiring diagram B(ii) below: a. Connect purple (+) and gray(-) coming out of emergency backup to purple (+) and gray (-) from LED RetroFit using wire nuts. b. Cover the yellow (+) and gray (-) coming out of emergency backup with wire nuts. c. Plug Out-N (white) and Out-L (black/white) of emergency backup connector together with LED RetroFit. d. Connect AC-N (white) and AC-L (black) of emergency backup to un-interrupted power supply wires. e. Connect AC-L (black) and SW (red) together. B. (i) 0-10V LED RETROFIT WITH SWITCH AND WITHOUT DIMMER WHITE HOT UNINTERRUPTED BLACK RED AC-N AC-L SW * * YELLOW GRAY PURPLE 0-10V DIMMER (+) 0-10V DIMMER (-) 0-10V DIMMER WIRES INSIDE 0-10V RETROFIT OR LUMINAIRE DIM (+) LED EMERGENCY BATTERY BACKUP GRAY 0-10V RETROFIT OR LUMINAIRE DIM (-) WHITE OUT-N BLACK/WHITE OUT-L LED RETROFIT (0-10V) B. (ii) 0-10V LED RETROFIT WITHOUT SWITCH AND WITHOUT DIMMER FOLLOW WIRING DIAGRAM B (i) BUT CONNECT AC-L (BLACK) AND SW (RED) TOGETHER. 12

Section 4 WIRING DIAGRAM C C.(i) For wiring non-dim LED Retrofit <23W with switch. Connect wires as outlined. Follow wiring diagram C(i) below: a. Cover both the purple (+) and gray (-) coming out of emergency backup with 2 wire nuts. b. Cover the yellow (+) and gray (-) coming out of emergency backup with 2 wire nuts. c. Plug Out-N (white) and Out-L (black/white) of emergency backup connector with LED RetroFit together. d. Connect AC-N (white) and AC-L (black) of emergency backup to un-interrupted power supply wires. e. Connect SW (red) coming out of emergency back up to switch C.(ii) For wiring non-dim LED Retrofit <23W without switch. Connect wires as outlined. Follow wiring diagram C(ii) below: a. Cover the purple (+) and gray (-) coming out of emergency backup with 2 wire nuts. b. Cover the yellow (+) and gray (-) coming out of emergency backup with 2 wire nuts. c. Plug Out-N (white) and Out-L (black/white) of emergency backup connector together with LED RetroFit. d. Connect AC-N (white) and AC-L (black) of emergency backup to un-interrupted power supply wires. e. Connect AC-L (black) and SW (red) coming out of emergency backup together. WIRING DIAGRAM C C. (i) NON-DIM LED RETROFIT <23W WITH SWITCH WHITE HOT UNINTERRUPTED BLACK AC-N AC-L * RED SW * * * * YELLOW GRAY PURPLE GRAY 0-10V DIMMER (+) 0-10V DIMMER (-) 0-10V DIMMER WIRES INSIDE 0-10V RETROFIT OR LUMINAIRE DIM (+) 0-10V RETROFIT OR LUMINAIRE DIM (-) LED EMERGENCY BATTERY BACKUP WHITE OUT-N BLACK/WHITE OUT-L LED RETROFIT (NON-DIM) C. (ii) NON-DIM LED RETROFIT <23 WITHOUT SWITCH FOLLOW WIRING DIAGRAM C (i) CONNECT AC-L (BLACK) AND SW (RED) TOGETHER 13

Thank you for choosing 6969 W. 73rd Street Bedford Park, IL 60638 WWW.LITETRONICS.COM CustomerService@Litetronics.com or 1-800-860-3392 vol.10 (11-21-17)