I. Synchronized Strobes 2=PROGRAMMING PROGRAMMING ENTER PASSWORD *****

Similar documents
Section 4: Operating Instructions

Fire alarm system specification for multiple tenant retail buildings

PS-Tools. User s Guide for the 50 Pt Addr Panel

MS Rev. 2/DACT-UD: Intelligent Addressable FACP with Optional 2nd Loop

DS9400 Series. Release Notes for Firmware V2.07. Fire Alarm Control Panel

IFP-2000 F r a en e h n y h t y PH P D

IntelliKnight 5820XL Addressable Fire Alarm Control System Sales Guide

Addressable Fire Alarm Control Panel

SECTION FIRE ALARM STANDARDS REVISED CONSTRUCTION STANDARD

Data/ Specification Sheet

GE Security EST Fire & Life Safety. Sophisticated io-series. Intelligent Life Safety Systems for small to mid-size buildings

PEGAsys. Multi-Loop Intelligent Suppression Control System FEATURES DESCRIPTION. Effective: March 2007 K

Laptop / PC Programming Manual

LifeAlarm Fire Alarm Control Panels

GE Security Vigilant Fire & Life Safety. Easy. V-Series Intelligent Life Safety Systems

30.45 Electric Release PDRP-2001

AutoPulse. AUTOPULSE IQ-318 AGENT RELEASING CONTROL PANEL Data/Specifications

AL602ULADA AL802ULADA AL1002ULADA

D8024, D9024, D10024 Analog Fire Alarm Control Panels Programming Guide

DATA SHEET CHEETAH XI 50 INTELLIGENT SUPPRESSION CONTROL SYSTEM DESCRIPTION APPROVALS: SYSTEM OPERATION. Form No. D

AFP-300/AFP-400 Analog Fire Panel

Fire Alarm System Fundamentals

Data Sheet Fire Safety & Security Products. System Overview. Initiating Circuits SXL-EX FACP 7906

CHEETAH XI INTELLIGENT SUPPRESSION CONTROL SYSTEM

12 Clintonville Road, Northford, CT Technical Manual MS-9200 DOCUMENT # /28/97 REV: B P/N 50428:B1 ECN

PWGSC Ontario MULTIPLEX FIRE ALARM SYSTEM Sect Region Project Page 1 Number R

FX-350/351/353 SERIES

DATA SHEET CYBERCAT 254 INTELLIGENT FIRE ALARM CONTROL SYSTEM DESCRIPTION APPROVALS: SYSTEM OPERATION. Form No. D

2. HVAC and smoke control systems; fire, smoke, and combination fire/smoke dampers. 5. Central control and monitoring system.

ADR Analog Addressable Fire Alarm Control Panel. Technical Manual. Control Panels. 3000En. En pdf

The CWSI System CALL WITH QUESTIONS. RELY ON OUR KNOWLEDGE. DEPEND ON OUR EXPERIENCE. (800)

Intelligent Analog/Addressable Fire Alarm/Voice Integration Systems. IntelliKnight TM Series

PART IV DETAILED SPECIFICATION

Section 8 System Operation

INTELLIKNIGHT MODEL 5700

AL802ULADA. NAC Power Extender. Installation Guide. (See Application Guide for additional information)

MONROE PUBLIC LIBRARY WATERFLOW MONITORING SYSTEM

INTELLIKNIGHT 5820XL. Installation and Operations Manual. Addressable Fire System. Document L8 04/01/2011 Rev: S P/N L8:S ECN

Intelligent Single Loop Fire Alarm Control Panel

SILENT KNIGHT IFP-1000

Installation Guide for AL800UL-ADA. NAC Power Extender. Rev

INTELLIKNIGHT 5820XL. Installation and Operation Manual. Addressable Fire System. Part Number H, 10/03

Syncro AS. Analogue Addressable Fire Control Panel. User Manual

UNIVERSITY SERVICES ANNEX James Madison University Harrisonburg, Virginia State Project Code: Architect s Project Number:

INTELLIKNIGHT 5820XL. Installation and Operations Manual. Addressable Fire System. Document L8 05/09/2012 Rev: T P/N L8:T ECN

Multi-Point Peripherals

AND ARCHITECT SPECIFICATIONS

NFS-320. Intelligent Addressable Fire Alarm System

intelligent fire alarm ID60series panels

MR-2350/2351 Series Analog/Addressable Fire Alarm Panel

INTELLIKNIGHT MODEL 5808

AL800ULADA. NAC Power Extender. Installation Guide

SECTION DIGITAL, ADDRESSABLE FIRE ALARM SYSTEM

C. All control equipment must have transient protection devices to comply with UL864 requirements.

Addressable NAC Output Module D327A

Sophisticated. io-series Intelligent fire alarm solutions for small buildings. An EDWARDS brand.

Silent Knight Software Suite Intelliknight Training

MODEL IFP-100. Installation and Operations Manual. Analog/Addressable Fire Control Panel. Part Number Rev L

D7024 Fire Alarm Control Panel

FireNET FN-LCD-S Serial Annunciator Installation and Operation Manual

Data/ Specification Sheet

Fire Alarm Control Panel AFP Operations Manual. Australian Edition. Document DOC /11/2015 Rev: P/N DOC :B

MODEL IFP-2000/ RPS-2000

STATE OF NORTH CAROLINA

Section 9 System Operation

AFP-400 Analog Fire Panel MEA E. City of Chicago Class 1: 1291E Class 2: 1792E GENERAL FEATURES. A Pittway Company

MIR2. System Operations Manual. P/N Rev 1.5 OCT98

Consultant Specification AGILE Wireless Fire Detection System

Fire Alarm Control Panel AFP Programming Manual. Australia Edition. Document DOC Rev: E 11/12/2018 ECN:

MS-9200UD/MS-9200UDE

Mircom FX /01/16

Architect s Project Number of 12 Fire Alarm/Smoke Detection Systems District Master Specs 2013 Edition

Product Guide Specification

INTELLIKNIGHT Model 5808

Nittan SPERA NETWORK FIRE ALARM/ DETECTION SYSTEM SPECIFICATION

CONTENTS Installation Precautions... 1 Chapter 1 Product Introduction... 2 Chapter 2 Technical Specifications... 3

PANELS, KEYPADS & MODULES. Take Fire Protection to the Next Level Fire Products from DSC

TrueAlarm Addressable Fire Alarm Control Panels

INTELLIKNIGHT MODEL 5700

Multiple Input and Output Modules

Intelligent 2 & 4 Loop Fire Alarm Control Panels

SMALL SCALE SOLUTIONS

XP6-C. Six Circuit Supervised Control Module and SYNC-1 Accessory Card

SECTION FIRE DETECTION AND ALARM

HS-5100, HS-5200, HS-5400 ANALOGUE ADDRESSABLE CONTROL PANELS. User Manual. Approved Document UI-ELAN-02 Revision 03

Notification Appliance Circuit Module

OPERATOR S MANUAL MR-2100/2200. Fire Alarm Control Unit. Revision 0 Document #: LT-2002

AL1002ULADA. NAC Power Extender. Installation Guide. (See Application Guide for additional information) Rev X

A. This Section covers fire alarm systems, including initiating devices, notification appliances, controls, and supervisory devices.

Agent Release Control Panel

PN: 51883:D ECN Field Charger/Power Supply FCPS-24FS6 FCPS-24FS8. Document # /14/05 Revision: D

HCA Series Conventional Fire Alarm System (HCA-2, HCA-2D, HCA-4, HCA-4D, HCA-8, HCA-8D) Installation and Operation Manual

TrueAlarm ES Analog Sensing

3.1 Introduction. 3.1 Introduction

ZX1e ZX2e ZX5e. Document No Issue 01 user manual

VISTA-128FBP/ V128FBP-24 Commercial Fire and Partitioned Burglary Alarm Control Panel

PSN-1000 & PSN 1000(E) Installation Manual

Release Control Fire Alarm Systems

This wiring diagram describes circuit connections for all models of the Series Quaestor-SZU Releasing Fire Control

FX Fire Alarm Control Panel. Installation and Operation Manual

Transcription:

This Supplement has been created to inform installers about the new Signal Line Circuit (SLC) capacity of 159 detectors and 159 modules per SLC loop; and Introduce two new FACP software features which (1) provide a synchronized strobe programming option, (2) allow the control panel to monitor and printout the sensitivity and drift compensation for each addressable smoke detector connected to the system; as well as to Provide information concerning 'Positive Alarm Sequence' and 'Printer Supervision'. I. Synchronized Strobes NAC Option for Synchronization Synchronization is a panel feature that controls the activation of notification appliances in such a way that all devices will turn on and off at exactly the same time. This is particularly critical when activating strobes which must be synchronized to conform with a variety of regulations as well as to avoid random activation which could cause a hazardous condition. The FACP can be programmed to operate with a variety of manufacturer's devices. Important: When a Notification Appliance Circuit with a mix of audible and visual devices is programmed for silenceable and the synchronization feature is selected, only the audible devices will be turned off if the Silence key is pressed. The visual devices (strobes, etc.) will continue to operate. Program Selection for Synchronized Strobes 1. Press the Enter or Mode key to display the following LCD readout: 1=READ@STATUS 2=PROGRAMMING Supplement to MS-9600 Manual, Rev A Smoke Detector Capacity Detector Sensitivity & Synchronized Strobes Positive Alarm Sequence & Printer Supervision Document 51583 Rev B 05/07/01 ECN 01-131 2. Press 2 to display the following: PROGRAMMING ENTER PASSWORD ***** 3. Enter the Master level password (default is 00000) to display the following: @@@@@PROGRAMMING 1=POINT@PROGRAM 2=ZONE@SETUP 3=LOOP@SETUP 4. Press down arrow key once to display the following: @@@@PROGRAMMING 1=SYSTEM@SETUP 2=AUTOPROGRAM 3=VERIFY@LOOP Page 1 of 5

5. Press 1 to display the following: @@@@SYSTEM@SETUP 1=TROUBLE@REM@@OFF 2=BANNER 3=TIME-DATE 6. Press down arrow key once to display the following: 11. Press 1 to program the NAC as a synchronized strobe circuit. The display will return to the following: @@@@NAC@# 1=ENABLED@@@YES 2=TYPE 3=SILENCEABLE 12. Press the down arrow key three time to display the following: @@@@SYSTEM@SETUP 1=TIMERS 2=NAC 3=RELAYS @@@@@NAC@# 1=SYNC@TYPE 7. Press 2 to display the following: 13. Press 1 to display the following: @@@@NACS 1=NAC@1 2=NAC@2 @@@@@NAC@SYNC@TYPE 1=SYSTEM@SENSOR 2=WHEELOCK 3=GENTEX 8. Press 1 to program NAC 1 or press 2 to program NAC 2. The following will be displayed (the # symbol will be replaced by 1 or 2): @@@@NAC@# 1=ENABLED@@@YES 2=TYPE 3=SILENCEABLE 14. Select the type of synchronized circuit according to the manufacturer's devices installed on the NAC by pressing the corresponding number key. Continue with the programming of the second NAC if desired. When all programming is completed, repeatedly press the ESC (Escape) key to store the program information and exit Programming mode. 9. Press 2 to display the following: @@@@@@@NAC@TYPE 1=BELL 2=HORN 3=STROBE 10. Press down arrow key once to display the following: @@@@@@@NAC@TYPE 1=SYNCED@STROBE 2=AUDIBLE 3=SIREN@CIRCUIT Page 2 of 5

II. Addressable Smoke Detector Sensitivity Software Enhancement The FACP software has been enhanced to include a feature which allows the control panel to monitor the sensitivity of each addressable smoke detector in the system. This eliminates the need for a service person to physically connect a sensitivity test meter to each device in the field. Detector Data An addressable smoke detector's ability to detect smoke can change over time as a result of component deterioration due to environmental contaminants and dirt. Each addressable smoke detector's data (sensitivity) can be printed by entering Read Status mode. 1. Pressing the Enter or Mode key on the control panel keypad will display the following LCD screen: 1=READ@STATUS 2=PROGRAMMING 2. Press 1 to display the following: @@@@READ@STATUS 1=SYSTEM@POINT 2=ZONES 3=POWER 3. Press down arrow key four times to display the following: @@@@READ@STATUS 1=FUTURE@USE 2=PRINTER/PC 3=PRINT 4. Press 3 to display the following: @@@@@@@PRINT 1=HISTORY 2=WALKTEST@LOG 3=DETECTOR@DATA 5. Press 3 to print the detector sensitivity data for all addressable smoke detectors installed on the system. Refer to the sample printout on the following page for information on interpreting the data. Note: If a printer is not available, it is possible to use the HyperTerminal feature found in the Windows program Accessories folder which is resident on most personal computers. Any settings which are configured in this feature must reflect the printer settings detailed in the FACP manual. Refer to the Windows manual for information on the HyperTerminal feature. Page 3 of 5

A printout, similar to the following example, will be generated if an optional printer is connected to the FACP. DEVICE# DEVICE TYPE %DRIFT COMP. CHAMBER TIME/DATE 1D001 SMOKE (PHOTO) 20 1478 12:01AM 01-08-2001 1D002 SMOKE (PHOTO) 20 1362 12:01AM 01-08-2001 1D003 SMOKE (PHOTO) 21 1452 12:01AM 01-08-2001 1D004 SMOKE (PHOTO) 20 1350 12:01AM 01-08-2001 1D005 SMOKE (PHOTO) 21 1245 12:01AM 01-08-2001 1D006 SMOKE (PHOTO) 21 1247 12:01AM 01-08-2001 1D007 SMOKE (PHOTO) 21 1250 12:01AM 01-08-2001 Chamber Value The Chamber Reading should be within the indicated ranges for the following smoke detectors: SD350(T), D350P(R) and SD300(T) Addressable Photoelectric Smoke Detectors: 405-2100 (obscuration of 1.00%/ft. to 3.66%/ft.) CP350 and CP300 Addressable Ionization Smoke Detectors: 750-2100 (obscuration of 0.50%/ft. to 1.44%/ft.) If the addressable smoke detector's Chamber reading is not within this acceptable range, clean the detector and check the Chamber reading again. If the reading is still not within the acceptable range, immediately replace the detector. Refer to the Fire Alarm Control Panel manual's Programming section for additional information on accessing Read Status mode and interpreting the smoke detector addresses. Drift Compensation Drift compensation uses software algorithms that identify and compensate for long-term changes in the data readings from each addressable smoke detector. These long-term changes in detector data readings are typically caused by dirt and dust accumulation inside the smoke chamber. Drift compensation performs the following functions: Allows a smoke detector to retain its original ability to detect actual smoke and resist false alarms, even as dirt and dust accumulate Reduces maintenance requirements by allowing the control panel to automatically perform the periodic sensitivity measurements required by NFPA Standard 72 The FACP software also provides filters to remove transient noise signals, usually caused by electrical interference. Alert The software determines when drift compensation for a detector reaches an unacceptable level that can compromise detector performance. When a detector reaches an unacceptable level, the control panel indicates a maintenance alert. The following table summarizes the three levels of maintenance alert: Low Chamber Level Value FACP Status Displays INVREP Indicates A hardware problem in the detector Alert DIRTY1 Urgent DIRTY2 Dust accumulation that is near but below the allowed limit. The Alert level indicates the need for maintenance before the performance of the detector is compromised Dust accumulation above the allowed limit Urgent Low Chamber Reading DIRTY Acceptable Range LOW VALUE Alert Page 4 of 5

The following information is provided as a clarification to the 9600 Fire Alarm Control Panel manual. 1. PAS (Positive Alarm Sequence) programming feature. Refer to the 9600 manual page 47 and page 114 for information on this option. The PAS option is not available in the initial release of the 9600 software. Do not attempt to use this feature since it is not yet functional in this product. Information on the availability of this feature will be made known on the manufacturer's internet site along with details on how to upgrade existing software. 2. Printer Supervision. Refer to the 9600 manual page 92 for information on this option. Printer supervision, when enabled, will typically detect the removal of the printer cable and will detect when the printer power has been turned off. Depending upon the brand of printer, other errors such as paper empty or printer off-line may be detected. Page 5 of 5