THE USE of DIRECT SOLAR ENERGY in ABSORPTION REFREGERATION EMPLOYING NH 3 H 2 O SYSTEM

Similar documents
Experimental Investigation of a Hybrid Evacuated Tube Solar Collector

STUDY ON HYBRID SYSTEM OF SOLAR POWERED WATER HEATER AND ADSORPTION ICE MAKER

Solar Heating and Cooling Systems

SOLAR PARABOLIC COLLECTOR ASSISTED EVAPORATIVE COOLING SYSTEM

CFD Analysis of a 24 Hour Operating Solar Refrigeration Absorption Technology

SOLAR WATER DISTILLATION BY USING WATER IN THE INNER GLASS EVACUATED TUBES

REVIEW OF DESIGN OF SINGLE EFFECT SOLAR POWERED VAPOUR ABSORPTION AIR CONDITIONING SYSTEM

Hot Water Making Potential Using of a Conventional Air- Conditioner as an Air-Water Heat Pump

Modelling the Performance of a Diffusion Absorption Refrigeration System

Performance Analysis of Li-Br Water Refrigeration System with Double Coil Anti-Swirl Shell and Coil Heat Exchangers

An Experimental Study of a Simple Vapour Compression Refrigeration System with Varying Parameters

Performance Study of Solar Heat Pipe with Different Working Fluids and Fill Ratios

Experimental investigation of Hybrid Nanofluid on wickless heat pipe heat exchanger thermal performance

Experimental Studies on Aero Profile Thermosyphon Solar Water Heating System

Performance evaluation of a liquid desiccant solar air conditioning system

PRODUCING COOLING FROM SOLAR ENERGY BY USING ADSORPTION CYCLE WITH ACTIVATED CARBON AND METHANOL PAIR

EXPERIMENTAL PERFORMANCE ANALYSIS OF AN AMMONIA-WATER DIFFUSION ABSORPTION REFRIGERATION CYCLE

EFFECT OF WATER RADIATOR ON AIR HEATING SOLAR COLLECTOR EFFICIENCY

GSJ: VOLUME 6, ISSUE 6, JUNE GSJ: Volume 6, Issue 6, June 2018, Online: ISSN

[Mali*, 4.(12): December, 2015] ISSN: (I2OR), Publication Impact Factor: 3.785

Thermodynamic Analysis of Ammonia-Water Absorption Refrigeration System with Ejector

SOLAR COOLING TECHNOLOGIES

Global Journal of Engineering Science and Research Management

Design and Performance Analysis of One Ended Evacuated Tubes at Different Air Flow Rates Nitin Panwar 1

Thermal Performance Enhancement of Inclined Rib Roughness Solar Air Heater

Heat Transfer in Evacuated Tubular Solar Collectors

Experimentation of Heat Pipe Used In Nano-Fluids

Performance Comparison of Ejector Expansion Refrigeration Cycle with Throttled Expansion Cycle Using R-170 as Refrigerant

INSTITUTE FOR ENVIRONMENTAL RESEARCH & SUSTAINABLE DEVELOPMENT NATIONAL OBSERVATORY OF ATHENS (NOA)

Recent Advances in Energy, Environment and Economic Development

An Experimental Study on Evacuated Tube Solar Collector for Heating of Air in India Avadhesh Yadav, V.K. Bajpai

Design and development of vapor absorption refrigeration system for rural dwellers. Adekeye, T. Oyedepo, S.O and Oyebanji, J.A

Solar Drying Techniques And Performance Analysis: A Review

COMPARATIVE ANALYSIS OF SINGLE AND DOUBLE EFFECT LiBr-WATER ABSORPTION SYSTEM

NOVEL COMPACT SORPTION GENERATORS FOR HEAT PUMP APPLICATIONS

Performance analysis of ejector refrigeration system with environment friendly refrigerant driven by exhaust emission of automobile

PERFORMANCE OF SOLID DESICCANT COOLING WITH SOLAR ENERGY IN HOT AND HUMID CLIMATE

EFFECT OF DIVERSE STREAM PATTERNS ON THE PERFORMANCE OF SOLAR AIR HEATER

Open Cycle Liquid Desiccant Air Conditioning Systems Theoretical and Experimental Investigations

Experimental Investigation of Flat Plate and V- Trough Solar Water Heater by using Thermal Analysis

FABRICATION SOLAR REFRIGERATION SYSTEM BY PELTIER EFFECT

Improving and Comparing the Coefficient of Performance of Domestic Refgirator by using Refrigerants R134a and R600a

Experimental characterization of an absorption diffusion machine based on light hydrocarbons for solar cooling

Experimental Investigation on Domestic Refrigerator by Shell and Tube Heat Exchanger after the Condenser Using Sub Colling of Refregaring Fluid

DESIGN, DEVELOPMENT AND TESTING OF CROSS FLOW CIRCULAR HEAT PIPE TO COOLING OF OIL

An Experiment of Heat Exchanger Produces Hot Water Using Waste Heat Recovery from Air Conditioning

Waste Heat Utilization of Vapor Compression Cycle for Operation of Vapor Absorption System

3. (a) Explain the working of a rotary screw compressor. [10] (b) How the capacity control is achieved in refrigerant compressor?

Subscripts 1-4 States of the given system Comp Compressor Cond Condenser E Evaporator vol Volumetric G Gas L Liquid

EXPERIMENTAL PERFORMANCE ANALYSIS OF SOLAR AIR HEATER WITH THREE DIFFERENT MODIFICATIONS IN ABSORBER PLATE

PROCESSING OF VEGETABLES IN A SOLAR DRYER IN ARID AREAS

Air Conditioning System with Modified Condenser Ducts and Evaporative Cooling

Comparison Simulation between Ventilation and Recirculation of Solar Desiccant Cooling System by TRNSYS in Hot and Humid Area

Performance Enhancement of Refrigeration Cycle by Employing a Heat Exchanger

PERFORMANCE ANALYSIS OF VAPOUR COMPRESSION THERMOELECTRIC REFRIGERATION SYSTEM WITH NOZZLE AND DIFFUSER THROUGH INCORPORATION OF PHASE CHANGE MATERIAL

Effect of Exhaust Gas Temperature on the Performance of Automobile Adsorption Air-Conditioner

Performance of non-cfc refrigerator driven by chilled water from 35 kw LiBr/H2O solar absorption cooling system

Experimental Study and Analysis of Flat Plate Solar Water Heater with Different Flow Rates using of Circulating Pump

Experimental & Analytical Investigation on Modified Solar Dryer with Recirculation of Air

EXPERIMENTAL STUDY OF CENTRIFUGAL HUMIDIFIER FITTED IN AN INDUSTRIAL SHED LOCATED IN TROPICAL CLIMATES

A Statistical Analysis of a Liquid Desiccant Dehumidifier/Regenerator in an Air Conditioning System

A Comprehensive Solar Powered Absorption Refrigeration System

International Journal of Research in Engineering and Innovation Vol-1, Issue-5 (2017), 68-72

International Journal of Research in Engineering and Innovation Vol-3, Issue-1 (2019), 1-5

Available online at Energy Procedia 6 (2011) MEDGREEN 2011-LB

Available online Journal of Scientific and Engineering Research, 2018, 5(11): Research Article

FABRICATION AND COMPARISON OF SOLAR WATER HEATER WITH AND WITHOUT SEMI CIRCULAR TROUGH

Experimental Investigation of Hot water Fired R134A-DMAC VARS System at Various Heat Source Temperatures

Adsorption refrigeration system using waste heat

Experimental study on mass transfer comparison of two liquid desiccants aqueous solutions

Enhancement of COP using Nanoadditives in Domestic Refrigerator

PERFORMANCE OF FORCED CONVECTION EVACUATED TUBE SOLAR GRAIN DRYER. BOOKER ONYANGO OSODO B. Ed.(TECH); M. Phil (Tech. Ed) (J98/25749/2011)

Conditioning of outdoor air using rotating disk type liquid desiccant-air contacting device

To investigate the surface properties for increasing efficiency of solar water heater

WASTE HEAT RECOVERY FROM DOMESTIC REFRIGERATOR Soma A. Biswas 1, Sandeep M. Joshi 2 1,2 Pillai College of Engineering

International Journal of Advance Research in Engineering, Science & Technology SOLAR HUMIDIFIER

Effect of Operating Parameters on the Performance of Direct Evaporative Cooler

ADVANCES in NATURAL and APPLIED SCIENCES

Performance Analysis of Solar Air Heater Using Three Wire Mesh

IJSRD - International Journal for Scientific Research & Development Vol. 3, Issue 03, 2015 ISSN (online):

Analysis of Constant Pressure and Constant Area Mixing Ejector Expansion Refrigeration System using R-1270 as Refrigerant

MULTI-CHANNEL R134A TWO-PHASE FLOW MEASUREMENT TECHNIQUE FOR AUTOMOBILE AIR-CONDITIONING SYSTEM

Refrigerator and Heat Pump Objectives

DESIGN AND CONSTRUCTION OF FORCED/NATURAL CONVECTION SOLAR VEGETABLE DRYER WITH HEAT STORAGE

Refrigerator/Heat pump

Numerical Studies On The Performance Of Methanol Based Air To Air Heat Pipe Heat Exchanger

EVALUATION OF A LIQUID DESICCANT AIR CONDITIONING SYSTEM WITH SOLAR THERMAL REGENERATION

DEVELOPMENT OF THE WORLD S FIRST SMALL-SCALE TWO-STAGE ABSORPTION CHILLER/HEATER/HOT-WATER SYSTEM

Performance of window air conditioner using alternative refrigerants with different configurations of capillary tube

Regenerator Design for Open Cycle Liquid Desiccant Systems Theoretical and Experimental Investigations

PERFORMANCE OF DEEP FREEZER BY USING HYDROCARBON BLENDS AS REFRIGERANTS

DESIGN, FABRICATION & PERFORMANCE ANALYSIS OF SOLAR AIR HEATER

Theoretical Performance Analysis of a Liquid Desiccant Air- Conditioning System for Air Heating and Cooling

A Review Paper on Extracting Waste Heat from the Engine Exhaust and Reutilizing in Car Air Conditioning

Experimental Study on Performance Parameters for Refrigerants R22, R410a and R404a at Various Air Outlet Temperatures

Fabrication & Performance Analysis of Solar Water Heater Using Porous Medium & Agitator

DESIGN AND FABRICATION OF THERMOELECTRIC COOLER CUM HEATER

EXPERIMENTAL INVESTIGATION OF VAPOUR ABSORPTION SYSTEM

Feasibility of a Liquid Desiccant Application in an Evaporative. Cooling Assisted 100% Outdoor Air System

CHAPTER I INTRODUCTION. In the modern life, electronic equipments have made their way

Transcription:

Iraqi Journal of Chemical and Petroleum Engineering Iraqi Journal of Chemical and Petroleum Engineering Vol.11 No.4 (December 2010) 13-21 ISSN: 12010-4884 University of Baghdad College of Engineering THE USE of DIRECT SOLAR ENERGY in ABSORPTION REFREGERATION EMPLOYING NH 3 H 2 O SYSTEM Prof. Dr. Adel A. Al-Hemiri and Ahmed Deaa Nasiaf Chemical Engineering Department, College of Engineering, University of Baghdad, Iraq ABSTRACT This work was conducted to study the coefficient of performance for solar absorption refrigeration by using direct solar energy using aqueous ammonia 0.45 mass fraction (ammonia water).the experiments were carried out in solar absorption system.the system consisted of solar collector generator (0.25 m 0.25 m 0.04m) and condenser cooled by a water bath followed by liquid receiver and evaporator. The results showed that the maximum generator temperature was (92-97 ) during June 2009, and the minimum evaporator temperature was (5 C - 10 C) for aqua ammonia system.. It was, also, found that the coefficient of performance, cooling ratio and amount of cooling obtainable increased with increasing maximum generator temperature and pressure. While the minimum evaporator temperature and concentration decreased with increasing maximum generator temperature and pressure. The coefficient of performance was (0.1096-0.2396). Keyword: Solar Energy, Absorption Refrigeration INTRODUCTION In the developing countries there is a growing interest in refrigeration for food preservation. Especially in rural areas, simple solar refrigerators working independently, i.e. not being provided with electrical energy, would be very valuable. Mechanical refrigerators powered by solar cells are available, but are too expensive [1]. In Iraq the climate features high temperature in summer season and high solar radiation. The director beam solar 13

THE USE of DIRECT SOLAR ENERGY in ABSORPTION REFREGERATION EMPLOYING NH 3 H 2 O SYSTEM radiation in north of Iraq is (5 6 kw.hr/m 2 ) and in the middle and south is (6 6.5 kw.hr/m 2 ) and (6.5 7 kw.hr/m 2 ) respectively [1].These two conditions helping to use solar energy for: Solar heating Solar refrigeration and air conditioning Solar desalination Solar food drying Solar photovoltaic Solar furnaces A solar refrigeration system consists of two components, a solar power units and a refrigeration unit. The solar power unit is based on either of two basic concepts, i.e. flat plate collectors or focusing collectors [2]. Flat plate collectors are flat blackened surfaces to absorb direct and diffuse solar radiation. Transparent cover and back insulation may be provided to reduce or control heat loss from the plate. On the plate, absorbed solar energy is converted to a desired form of energy, usually heat, and means are provided to remove that energy, usually as heated water or air. Flat plate collectors are generally suitable for operation in a fixed orientation. The refrigeration unit can be either a continuous or an intermittent absorption system. The intermittent absorption refrigeration is preferred.the intermittent refrigeration cycle has two major operations, regeneration and refrigeration.regeneration is the process of heating the refrigerant and absorbent fluid to drive off the refrigeration vapour and condense the vapour in a separate container.refrigeration takes place when the liquid refrigerant vaporizes; producing a cooling effect around the evaporator.the refrigerant is reabsorbed by the absorbent [2]. The first absorption refrigeration system was developed by Ferdinand Carre in 1860 [3]. This was the first heat operated absorption system and consists of an evaporator, condenser, generator, pump, and absorber. This unit was designed to operate with ammonia as the refrigerant and water as the absorbent. In the University of Wisconsin, Williams [4] built a small food cooler in 1957 intended for use in underdeveloped rural areas. Ammoniawater and R-21-glycol ether were used as working solutions. This study showed that refrigeration can be achieved by the use of intermittent absorption refrigeration cycles. Although performance is limited by the characteristics of the intermittent cycle, the simplicity of the system accounts for the low temperature obtained in the evaporator. Finally, the study showed that ammonia-water has a superior performance over R-21-glycol ether in an intermittent refrigeration system. Chinnappa (1962) built a simple intermittent refrigerator operated with a flat-plate collector. An ammonia-water solution was used as the working fluid. While it has been generally expected that the flat-plate collector would be more suitable for the lower temperature of generation required in air conditioning, tests in the investigation by Chtnnappa (1962) indicated that it is possible to use a flat-plate collector incorporated with the generator to produce refrigeration at a temperature as low as -12 C. It is noted that ice can be produced in this refrigerator at one kg a day per 0.7 m 2 of solar collecting surface. Results in this 14

Prof. Dr. Adel A. Al-Hemiri and Ahmed Deaa Nasiaf investigation were not spectacular, but they showed that a simple intermittent refrigerator using a low temperature heat collecting device such as the flat-plate collector can achieve cooling [5]. The first major project on an all solar absorption refrigeration system was undertaken by Trombe and Foex (1964)[6]. Ammonia-water solution is allowed to flow from a cold reservoir through a pipe placed at the focal line of a cylinder-parabolic reflector. Heated ammonia-water vaporized in the boiler is subsequently condensed in a cooling coil. The evaporator is a coil surrounding the container used as an ice box. The cylindro-parabolic reflector measured 1.5 m'. In the prototype trials, the daily production of ice was about 6 to 4 kilograms of ice per square meter of collecting area for four-hour heating. The design by Trombe and Foex is very promising and should be studied further although modifications may be necessary on the solar collector, boiler, and condenser. Farber (1970)[7] has built the most successful solar refrigeration system to date. It was a compact solar ice maker using a flat-plate collector as the energy source. It was reported that an average of about 42,200 kj of solar energy was collected by the collector per day and ice produced was about 18.1 kilograms. This gave an overall coefficient of performance of about 0.1 and 12.5 kilograms of ice per m 2 of collector surface per day. Swartman and Swaminathan (1971) [8] built a simple, intermittent refrigeration system incorporating the generator-absorber with a 1.4 m 2 flatplate collector. Ammonia water solutions of concentration varying from 58 to 70 percent were tested. Tests were relatively successful; evaporator temperatures were as low as -12 C, but due to poor absorption, the evaporation rate of ammonia in the evaporator was low. Staicovici [9] made an intermittent single-stage H 2 O-NH 3 solar absorption system of 46 MJ/cycle (1986). Solar collectors heat the generator. Installation details and experimental results were presented. The system coefficient of performance (COP) system varied between 0.152 and 0.09 in the period of May September. Solar radiation availability and the theoretical (COP), also applicable to the Trombe-Foex system, were assessed. Reference was made to evacuated solar collectors with selective surfaces. Actual (COP) system values of 0.25 0.30 can be achieved at generation and condensation temperatures of 80 C and 24.3 C respectively. In 1993 Sierra, Best and Holland [10] made a laboratory mordent of absorption refrigeration. Using ammonia - water solution at 52 % concentration by weight and the total weigh is 38 kg. this system was operated intermittently using this heat source.a heat source at temperature no higher than 80 C was used to simulate the heat input to an absorption refrigeration from solar pond.in this system the temperatures of generator was as high as 73 C and evaporator temperatures as low as -2 C. Tap water was used to remove the heat generated from the condensation of the ammonia vapor and the absorption of the refrigerant in the water. The temperature of the tap water was near the ambient laboratory temperature of 28 C. The COP for this unit working under such condition was in the range 0.24 to 0.28. 15

THE USE of DIRECT SOLAR ENERGY in ABSORPTION REFREGERATION EMPLOYING NH 3 H 2 O SYSTEM In 2000 Hammad and Habali [11] made a steel sheet cabinet of 0.6 m x 0.3 m face area and 0.5 m depth. The cabinet was intended to store vaccine in the remote desert area, away from the electrical national grid. A solar energy powered absorption refrigeration cycle using Aqua Ammonia solution was designed to keep this cabinet in the range of required temperatures. The ambient temperatures reached about 45 C in August. A computer simulation procedure was developed to study the performance and characteristics of the cooling cycle. The simulation included MATLAB computer programs for calculation the absorption cycle. In this system using a cylindrical solar concentrator extended the daily operating time to about 7 h and increased the output temperature up to 200 C and the range of the COP was between 0.5 to 0.65.While the temperature which gives optimum condition (of COP =0.65 )was 120 C. For this study a solar absorption refrigeration unit was constructed. The Fig. 1 Schematic diagram of the equipment used working fluids employed was aqueous ammonia (25wt% NH 3 H 2 O).The system was operated during the months of June and July (2009) for a period of 8 hours per day (8 am to 4 pm). 16

Prof. Dr. Adel A. Al-Hemiri and Ahmed Deaa Nasiaf Assessment of the system is by determining the following relevant parameters: Cooling obtainable Cooling ratio Solar coefficient of performance (C.O.P). EXPERIMENTAL WORK Apparatus The systems consist of generator. It was fabricated from 2 mm thick stainless plate (316) painted black to improve on it s solar radiation absorbing capabilities. The section is rectangular and the dimensions are (25 cm x 25cm x 5 cm) and at 20 inclined angle. The volume is 2.5 liters. Steel was used because other nonferrous material like copper and brass are attacked by ammonia. All side of the generator were insulated except the solar side. The second part of the system is the condenser which consists of a small coil (1cm diameter and 20 cm length 0.2 cm thickness) was immersed in cold water bath after that the receiver follows the condenser.the benefit of receiver is to collect liquid condensate outside of the condenser. And the evaporator is stainless steel pipe 1cm diameter and 10 cm length 0.2 cm thickness (Fig 1). Experimental procedure During the regeneration, valve A is open and valve B is closed(fig. 1), and the strong solution in the generator being heated by the flat-plate collector producing vapor at a high pressure, the weak solution returns from the top to the bottom of collector. The vapor in the top header collector is mainly ammonia because water has a much lower volatility than ammonia. The ammonia vapor passes into the condenser which is immersed in a cold water bath to keep it cool, the pressure is uniform throughout the system. When heating stops at 14:30 PM (maximum generators temperature and pressure) valve A is closed and the vapor pressure in the generator drops. The concentration in the generator is now less than it was before regeneration, after that valve B was opened. The condenser now functions as the evaporator. Ammonia vaporizes due to the pressure difference between the generator and evaporator. The vaporization of ammonia absorbs heat from the surroundings of the evaporator, thus producing the refrigeration effect. Ammonia vapor from the evaporator passes through the pipe and taken to the bottom of the collector so that the incoming vapor bubbles through the solution thus facilitating absorption in it. Refrigeration continues until all the liquid ammonia in the evaporator has vaporized. A full cycle of operation has now been completed. The temperature and pressure of the evaporator and absorber were recorded every 5 minutes. While the ambient, solution and generator temperature and the generator pressure were recorded at 30 minutes intervals. Results of experiments are given in table (1) in the appendix. DISCUSSIONS Variation of Temperatures and Pressure with Time in Regeneration Cycle 17

THE USE of DIRECT SOLAR ENERGY in ABSORPTION REFREGERATION EMPLOYING NH 3 H 2 O SYSTEM Fig. 2 shows the variation of generator (T g ), solution (T so ), ambient (T am ) temperature with time (t). The average mean generator temperature (T gavr ) was between (61.5 to 66.7 C).The maximum generator temperature (T gmax) for five runs was between (92 to 97 C) this maximum temperature recorded at 02:30 PM because the sun at this time is vertically to collector. In the same figure the pressure variation with time it also shown.initial pressure was for five runs (average) 2.4 bar and reached to maximum pressure(pg) at 02:30 PM.The maximum pressures was about 12.9 bar for generation cycle, as a result of heating the generator and closing the exiting valve of the generator. And return to initial value after complete absorption cycle. Fig.3 shows the variation between evaporator (T e ), absorber (T ab ) temperature and evaporator (P e ), absorber (P ab ) pressure with refrigeration time. In this figures the evaporator temperature was about (30 to 35 C) and pressure (10.4 to 10.7 bar). At this stage the temperature of surrounding more than evaporator temperature causing transfer of heat from surrounding to evaporator. The minimum evaporator temperature was (5 to 10 C) for five runs. At these temperatures liquid ammonia was evaporated and evaporator pressure dropping to initial pressure (2.4 to 2.7 bar). Liquid ammonia was evaporated at ( 5 to 10 C) and enter to absorber.the condition was (25 C) and (1.7 bar) the vapor of ammonia absorbed in absorber the temperature of absorber increases to (32 to 34 C) because the absorption is exothermic. The pressure in absorber at the end of refrigeration cycle equal to evaporator pressure. Fig.2 Variation of generator, ambient and solution temperature and generator pressure with time (NH 3 - H 2 O) Fig.3 Variation of temperature and pressure in the evaporator and absorber with time (NH 3 -H 2 O) Variation of Temperatures and Pressure with Time in Refrigeration Cycle 18

Prof. Dr. Adel A. Al-Hemiri and Ahmed Deaa Nasiaf Effect of maximum generator temperature and pressure on evaporator temperature Fig. 6 shows the Effect of maximum generator temperature and pressure on evaporator temperature. The minimum evaporator temperature (Temin) decreases with increasing maximum generator temperature and pressure. Fig.4 Effect of maximum generator temperature on C.O.P (NH 3 -H 2 O) Effect of Maximum Temperature on C.O.P Figs.4 and 5 shows the effect of maximum temperature and pressure on C.O.P For five runs it was found the C.O.P increases with maximum generation temperature and pressure.this is because the quantity of NH 3 evaporated increases with increasing maximum generation temperature. Fig.6 Effect of maximum generator temperature on evaporator temperature (NH 3 -H 2 O) CONCLUSIONS The following conclusions could be drawn from the present research during the months of June and July (2009), Fig.5 Effect of maximum generator pressure on C.O.P (NH 3 -H 2 O) 1. The maximum generator temperature was found to be 97 C. 2. The range of C.O.P for the aqueous ammonia system was (0.1096-0.2396). 3. The range of minimum evaporator temperature was (5 C - 10 C). 4. Cooling ratio and cooling obtainable increases with increasing maximum generator temperature and pressure. 5. The Final concentration decreases with increasing maximum generator temperature and pressure. 19

THE USE of DIRECT SOLAR ENERGY in ABSORPTION REFREGERATION EMPLOYING NH 3 H 2 O SYSTEM NOMENCLATURE C.O.P Coefficient of performance T am Ambient temperature P ab Absorber pressure Te Evaporator temperature P e Evaporator pressure T emin Minimum evaporator temperature P g Generator pressure T g generator temperature t Time T gavr Average generator temperature T ab Absorber temperature T gmax Maximum generator temperature T gmean Mean generator temperature T so Solution temperature REFERENCES [1]Abdul Hai, S and Abdul Jabbar, K(1984)"Iraq s National Paper,Solar in Iraq",Symposium using solar energy in Heating and cooling, Organization of Arab Petroleum Exporting and Solar Energy Research Center in the Scientific Research Council,Baghdad. [2]Sorensen B (2004) Renewable Energy ",third edition by Elsevier Science. [3]Enibe S. O. (1997) Solar Refrigeration for Rural Applications", Elsevier Science, Renewable Energy, Vol. 12, No. 2, pages 157-167s. [4]Williams, D. A., Chung, R., Lof, G. O. G., Fester, D. A., and Duffle, J. A. (1957), "Intermittent Absorption Cooling Systems with Solar Regeneration", Paper No. 57-A-60, A.S.M.E. [5]Chinnappa, J. C. V., (1962), " Performance of an Intermittent Refrigerator Operated by a Flat-Plate Collector Solar Energy Vol. 6, pages 143-150. [6]Trombe, F., and Foex, M., (1964)," Economic Balance Sheet of Ice Manufacture with an Absorption Machine Utilizing the Sun as the Heat Source " New Courses of Energy, Vol. 4, U.N. Publication Sales No. 63.1.38, pages 56-59. [7]Farber, E. A., (1970)," Design and Performance of a Compact Solar Refrigeration System "Paper No. 6/58, 1970, International Solar Energy Society Conference, Melbourne, Australia. [8]Swartman, R. K., and Swaminathan, C., (1971)," Solar Powered Refrigerator, Mechanical Engineering" June 1971, Vol. 6, page. 22-24. [9]Staicovici M. D.,(1986)" An Autonomous Solar Ammonia-Water Refrigeration System", Solar Energy, Volume 36, Issue 2, 1986, Pages 115-124. [10]Kouremenos D. A, Antonopoulos K. A and Rogdakis. E. (1990)," Performance OF A Solar Driven Compound (NH3/H20-20/LiBr) Sorption Refrigeration System In [11] Athens",Solar & Wind Technology Vol. 7, No. 6, pages 685-597. 20

Prof. Dr. Adel A. Al-Hemiri and Ahmed Deaa Nasiaf [12]Hammad M, Habali S. (2000)," Design and Performance Study of a Solar Energy Powered Vaccine Cabinet",Bywww.elsevier.com/locate/ap thermeng,applied Thermal Engineering 20 Pages 1785-1798. [13]Nasiaf, A.D., (2010) "The Use of Direct Solar Energy in Absorption Refrigeration", MSc Thesis, Chem. Eng. Dept., Baghdad University. APPENDIX Table 1 Summary of Experimental Results for Aqueous Ammonia System[13]. Date June 2009 Day 3 9 11 14 22 Regeneration Units Initial mass of solution gm 1000 1000 1000 1000 1000 Initial mass concentration _ 0.45 0.45 0.45 0.45 0.45 Initial solution temp C 35 34 35 34 33 Max solution temp C 90 96 93 94 91 Max generator Pressure bar 12.5 12.9 12.7 12.8 12.6 Incident solar radiation KJ 532 532 532 532 532 Heat to collector plate KJ 148.4 241.58 194.75 222.71 176.62 Mean generator temp C 62.5 65.5 63 64 62 Condenser temp C 30 30 30 30 30 Final concentration _ 0.42 0.38 0.41 0.39 0.4 Refrigeration NH 3 evaporated gm 51.7 113 88.3 98.3 67.8 Min evaporator temp C 10 5 8 6 8 Cooling obtainable KJ 58.32 127.47 94.95 111.35 77.59 Cooling ratio _ 0.3929 0.5275 0.4875 0.4999 0.4393 Solar C.O.P _ 0.1096 0.2396 0.1784 0.2093 0.1458 21