CLARK COUNTY FIRE DEPARTMENT Fire Prevention Bureau

Similar documents
CLARK COUNTY FIRE DEPARTMENT Fire Prevention Bureau

FOOD PREPARATION WITHIN EXHIBITS

CLARK COUNTY FIRE DEPARTMENT Fire Prevention Bureau

CLARK COUNTY FIRE DEPARTMENT Fire Prevention Bureau

Washington State Convention Center Fire Safety Guidelines

Clark County Department of Building & Fire Prevention 4701 West Russell Road, Las Vegas, NV (702) FAX (702)

Dear Exhibitor, To assist in th. and safety issues that you may encounter with your booth.

Tents and Temporary Membrane Structures Packet

FIRE DEPARTMENT PERMIT GUIDELINES

TENTS AND TEMPORARY MEMBRANE STRUCTURES PERMIT PROCEDURE

Convention Center Rules & Regulations

Tents and Temporary Membrane Structures Permit Procedure

Calgary Fire Department Indoor Special Event Requirements. August calgary.ca /fire call

PALM SPRINGS FIRE DEPARTMENT REGULATIONS FOR TRADE SHOW EXHIBITORS, CONVENTIONS AND SPECIAL EVENT GATHERINGS BASED ON THE 2010 CALIFORNIA FIRE CODE

EXCELSIOR FIRE DISTRICT

MULTI-LEVEL & COVERED BOOTH CONDITIONS

Exhibits and Trade Shows Permit Application

REGULATIONS FOR OUTDOOR GATHERINGS AND EVENTS TENTS & MEMBRANE STRUCTURES

Outdoor Festival and Special Event Guidelines

FIREDEPARTMENT REGULATIONS AND GUIDELINES

City of Leduc Fire Services Indoor Special Event Requirements

ATTACHMENT B FIRE CODE REQUIREMENTS FOR EXHIBITS AND SPECIAL EVENTS

Fire and Life Safety Requirements San Mateo City Special Events

FIRE MARSHAL REGULATIONS

CLARK COUNTY FIRE DEPARTMENT Fire Prevention Bureau

Township of Upper Providence Office of the Fire Marshal

CLARK COUNTY FIRE DEPARTMENT Fire Prevention Bureau

NATURAL/LP GAS, COOKING, OPEN FLAME, HEAT PRODUCING DEVICE AGREEMENT FORM

FIRE AND LIFE SAFETY REQUIREMENTS FOR SPECIAL EVENTS STANDARD

30 DAY TEMPORARY TENT APPLICATION ON EXISTING COMMERCIAL PROPERTY

Minimum Information Required to Process your Special Occasion Application. Parking area Access to site

CLARK COUNTY FIRE DEPARTMENT Fire Prevention Bureau

Note: The event coordinator is responsible for compliance of all regulations.

SALT LAKE OFF-ROAD EXPO 2018 Sponsor Information Friday-Saturday April 27 th & 28 th 2018 South Towne Expo Center Hall 5 Off-Roaders Unite!

CLARK COUNTY FIRE DEPARTMENT Fire Hazard & Prevention Services 575 E. Flamingo Road, Ls Vegas, NV (702) FAX (702)

DEPARTMENT OF FIRE AND EMERGENCY SERVICES

UC Irvine Environmental Health & Safety TITLE: Special Events Program

PLACES OF ASSEMBLY CHAPTER 17

Fire Safety Guidelines and Requirements CenturyLink Field and Event Center June 2015

CITY OF GREATER SUDBURY (CGS) ARENA EVENTS FIRE REGULATIONS

2018 IFC Update. Based on the 2018 International Fire Code, (IFC ) Goal. Objectives. Content

4. Distances to property line, buildings, other tents, parked vehicles and engines;

SANTA ROSA FIRE DEPARTMENT FIRE PREVENTION BUREAU STANDARD

City of Cleveland. Division of Fire Fire Prevention Bureau 1645 Superior Avenue Cleveland, Ohio Standard Operating Procedure 18

Anticipated Date and Time for Completion of Break-Down:

All temporary special events held within the City of Orlando must be approved and inspected by the Orlando Fire Department prior to holding the event.

CLARK COUNTY FIRE DEPARTMENT Fire Prevention Bureau. Permit fees shall be assessed in accordance with the Permit Fee Schedule

McCormick Place Fire Safety Regulations

PLANNING AND MANAGEMENT GUIDE for PUBLIC ASSEMBLY EVENTS

Orange County Fire Rescue Department Office of the Fire Marshal 7079 University Blvd. Winter Park, FL Phone: Fax:

For additional information please contact the Chesapeake Fire Prevention Office at or at

CLARK COUNTY FIRE DEPARTMENT Fire Prevention Bureau

General Festival Conditions & Temporary Use of Tents Conditions of Approval

CLARK COUNTY FIRE DEPARTMENT Fire Prevention Bureau

CITY OF OKLAHOMA CITY SPECIAL EVENT REQUIREMENTS Revised January, 2011

CLARK COUNTY FIRE DEPARTMENT Fire Prevention Bureau

2009 International Fire Code Errata. SECOND PRINTING (Posted April 6, 2010)

Canby Fire District 221 S. Pine Street Canby, OR97013 Bus Fax Fire Marshal, Todd Gary

FIRE & SAFETY REGULATIONS (Updated )

South Elgin & Countryside Fire Protection District

FIRE PREVENTION EXHIBIT GUIDELINES

Note: The event coordinator is responsible for compliance of all regulations.

MUST BE APPROVED IN ADVANCE

Fire Regulations for Exhibitors

SafetyNet FIRE MARSHAL S OFFICE. Food Booth and Vendor Regulations

All orders are governed by the GES Payment Policy and GES Terms & Conditions of Contract as specified in this Exhibitor Services Manual.

PERMIT APPLICATION Central Pierce Fire & Rescue 902 7th Street NW - Puyallup, WA Telephone (253) Fax: (253) 538.

FACT SHEET Program: Event Fire Safety

REQUIREMENTS FOR EVENTS AND TEMPORARY STANDS AT FAIRS AND SHOWS

FIRE PREVENTION 29 CFR Ursinus College, Collegeville, PA

CITY OF LONG BEACH Department of Development Services BUILDING AND SAFETY BUREAU TENANT IMPROVEMENT GROUP A FIRE PLAN REVIEW CHECKLIST

COMPLIANCE WITH THIS PUBLICATION IS MANDATORY

MINNESOTA STATE DEPARTMENT OF PUBLIC SAFETY

EXHIBITOR KIT TABLE OF CONTENTS

REQUIREMENTS FOR TENTS, CANOPIES & MEMBRANE STRUCTURES

Convention Center Rules and Regulations

FACILITY REGULATIONS

FACILITY REGULATIONS

LOCAL AMENDMENTS TO THE INTERNATIONAL FIRE CODE 2006 EDITION

FIRE DEPARTMENT CONDITIONS BELLEVUE FESTIVAL OF THE ARTS Fire Retardant or Flame Retardant Treatment

CORPUS CHRISTI FIRE PREVENTION MOBILE FOOD VENDOR REQUIREMENTS

SAFETY GUIDELINES INDIANA STATE FAIRGROUNDS & EVENT CENTER. Fairgrounds Security:

FIRE SAFETY GUIDELINES

MOBILE FOOD VENDING Food Trucks & Trailers

John Jay College of Criminal Justice HOT WORK PERMIT STANDARD OPERATING PROCEDURES

SPECIAL AMUSEMENT OCCUPANCIES HAUNTED HOUSE, SCARE HOUSE OR MAZE

Temporary Haunted Houses

Demolition Permit Application (Please print and complete ENTIRE form)

FIRE EXTINGUISHER SPACING & INSTALLATION GUIDELINES

LIFE SAFETY CODE ESSENTIALS PRESENTED BY: LARRY VIGIL, RISK CONSULTANT

HLS Checklist Explanation and Examples

FIRE PREVENTION CODE

1303 Trans Canada Way SE Medicine Hat, AB T1B 3Z9 Phone

comprised the facility Cables Candles be placed

SPECIAL EVENTS INSTRUCTIONS AND REQUIREMENTS Must apply at least 2 weeks PRIOR to Event Date

Conventions. Trade Shows. Special Events. Exhibits

STATE OF MARYLAND DEPARTMENT OF STATE POLICE OFFICE OF THE STATE FIRE MARSHAL

Salve Regina University Fire Safety Policy for Events in Assembly Occupancies (Original 2006 revised & updated January 2010 & October 2014)

Fire/Life Safety Policy

VENUE (LACC) GUIDELINES

Transcription:

CLARK COUNTY FIRE DEPARTMENT Fire Prevention Bureau 575 E. Flamingo Road, Las Vegas, NV 89119 (702) 455-7316 FAX (702) 455-7347 Permit Type: 105.8.p2 Effective Date: August 1, 2010 Revision Date: none TITLE: PLACES OF ASSEMBLY SCOPE: Provide the minimum submittal requirements for Temporary Assembly Permits. PURPOSE: To standardize plan/permit requirements required by the Fire Department in accordance with 2005 Clark County Fire Code. SUBMITTAL REQUIREMENTS: The Event Operator, herein referred to as the Applicant, shall process a Places of Assembly Permit Application. The permit application can be obtained at http://fire.co.clark.nv.us/(s(30wk54bk31q4e055kb0tu0zr))/permits.aspx. Provide the three sets of plan and three sets of fabric flame proofing certificates as described herein. Regular submittals for Places of Assembly will be reviewed within a 10-business day turn around period. Expedited plans will have a turn around time of no greater than five (5) business days or before the date of the event. The permit is valid for the duration of the event as specified by the Applicant. Revisions to approved plans are required to be submitted and approved. Revisions will be assessed additional plan review fees. A copy of the previously approved plan shall accompany the revised submittal to facilitate the review. Clearly indicate all changes to the revised plans by clouding the change with a delta number to signify the date of plan change. When several changes have been made, the Plans Checker may also require a detailed list of changes. Resubmittals of plans with corrections shall include a copy of the previously submitted plans so that the Plans Checker can determine that the required corrections have been made. Page 1 of 11

The application should be submitted at least four weeks prior to the event. Plans may be accepted inside of four weeks when CCFD staff is available to review them and expedite fees are paid if applicable. The submittal must include: Three (3) sets of scaled floor plans on minimum 11-inch X 17-inch paper All drawings shall be drawn to a measurable scale. i.e. 1/8 inch = 1 foot, 1/16 inch = 1 foot, 1 inch = 10 feet. Hand delivered and U.S. Postal Mail are the standard methods of submittal. FAX submittals are not acceptable. 1. The following information is required on all plans: a) Provide contact person, their telephone & fax numbers, move in and move out dates for the event, name of property, address of property, name of specific room to be used. A detail shall be drawn to depict the location of these rooms, adjoining rooms and hallways in relation to the building they occupy. See the required information block given in Appendix A. b) Type of convention/special event (Display items: Equipment, materials, vehicles, pyrotechnics, open flame devices, candles, cameras, sound booths and food service areas). c) Dimensions shall be drawn for the usable square footage to be occupied and the total square footage of the room. Maximum occupant load permitted in the useable area shall be calculated and provided. d) Location and dimensions of all available exits. e) Width of all aisles for egress & cross aisles around all tables, booths and theater style seating shall be drawn to scale and dimensions shall be provided. No dead end aisles greater than 20 feet in length. Aisles around round or rectangular tables with chairs on both sides shall be a minimum of 6 feet from table edge to table edge. Aisles around convention booths shall be a minimum 8 feet wide. Aisles for egress around theater style seating shall be a minimum 6 feet wide. f) Sizes and locations of booths shall be shown on the plans. The sizes shall be provided in square feet. The plans shall show the heights of the booths and whether the booths have multiple levels. g) All tables with chairs shall be drawn to scale and dimensions shall be provided. Chairs for theater style seating in groups of three (3) or more shall be banded together. Page 2 of 11

h) A line table shall be provided to show the differences between walls, curtains and other items in the room. i) Location of all fire extinguishers and fire hose cabinets shall be marked on plans. A symbols table shall be provided to show the differences between a fire hose cabinets, fire extinguishers, etc. 2. Separate permits are required for other operational permits contained within the assembly. Typical operations that require separate permits that are present in assembly spaces include: Candles and Open flames Flame effects Fireworks/pyrotechnics Hot Work Operations Liquid or gas-fueled vehicles or equipment for display in assembly occupancies Fire systems for covered booths exceeding 1,000 square feet SPECIFICATIONS AND REQUIREMENTS: See Appendix B for definitions specific to Temporary Assemblies: Occupant Loads: Occupant Loads are to be controlled by the Event Operator and reported accurately. Assembly Permits will be revoked by CCFD when the actual occupant load exceeds the reported occupant load. Maximum occupant load shall be calculated versus the total or useable square footage of the room. Maximum occupant load shall be calculated by dividing the square footage of the room by 15 for an event utilizing tables and chairs or booths for a convention; dividing by 7 for an event utilizing fixed seating. FUNCTION OF SPACE OCCUPANTS LOAD PER FLOOR AREA Exhibition Floors 15 net * Fixed Auditorium Seating Actual Number of Seats General Sessions Actual Number of Seats General Session Standing Room 7 net* (if allowed) Grandstand / Bleachers one person per 18-inches bench width Concert Seating Actual Number of Seats Concert Standing Room 5 net* (if allowed) Stages and Platforms 15 net* Back Stage 200 gross** Kitchens 200 gross** Pre-function Non-simultaneous or per master egress plan Registration Non-simultaneous or per master egress plan Business Centers 100 gross** Page 3 of 11

*Net = remaining area when not including non-useable circulation space (e.g. space taken by décor, displays, props and the like) ** Gross = all area including non-useable circulation space (e.g. equipment, pillars, stock items, and the like) Assembly Occupancy Arrangements: 1. Width of all aisles for egress & cross aisles around all tables, booths and theater style seating shall be drawn to scale and dimensions shall be provided. No dead end aisles greater than 20 feet in length. Aisles around round or rectangular tables with chairs on both sides shall be a minimum of 6 feet from table edge to table edge. Aisles around convention booths shall be a minimum 8 feet wide. Aisles for egress around theater style seating shall be a minimum 6 feet wide. 2. Theater style seating rows for General Sessions, Concerts and the like shall be served by minimum 44-inch aisles. Rows shall not exceed 100 seats per row when an aisle is available at both ends of the row. A minimum 12 inch clear width is required between rows. The clear width between rows shall be increased by 0.3 inches for every seat over 14, but shall not be required to exceed 22 inches. 3. Aisles around convention exhibition booths are to be a minimum of 8-feet wide. An allowance for a 4-foot wide aisle in a length limited to 50-feet will be acceptable. 4. Master Exiting Plans approved by Clark County Development Services (CCDS) (Building Department) shall supersede all of the above. Means of Egress: 1. Exits and their capacity shall be in accordance with master egress plans approved by Clark County Development Services Building Division. 2. The available exit capacity must be greater than or equal to the number of occupants (occupant load). 3. The exit capacity shall be calculated by the formulas: Exit Capacity of level Exit Access and Doors. An egress factor of 0.20 inch per person shall be provided. Alternately, an egress factor of 1 foot of exit width for 60 persons shall be provided. Exit Capacity of Ramps and Stairs. An egress factor of 0.30 inch per person shall be provided. Alternately, an egress factor of 1 foot of exit width for 40 persons shall be provided. Where the master egress plans show alternate egress factors, the alternate egress factors shall be permitted. 4. Exiting shall be provided on at least 2 sides of the room being occupied. If 2 or more exits are required in assembly occupancy, they must be separated by a minimum distance equal to or greater than one half the diagonal distance of the room being used to achieve the adequate exiting separation distance Page 4 of 11

5. The exit access ways shall not be less than the combined required capacity of the converging aisles. Width of access ways need not be greater than the required width of the exit doors to which they lead. 6. Booths, tables, displays and the like shall not restrict the required exit capacity. 7. No life safety features or components (.e.g. EXIT signs, emergency lighting, fire extinguisher cabinets, hose cabinets, strobes, and horns) shall be obstructed by decorations or set up materials. Any proposed relocation of such devices shall be noted on plans. Any proposed relocation of fire alarm devices and fire suppression devices shall require submittal of permits to address the work, as required. Fire Extinguishers: 1. Fire extinguishers originally placed by the building owner as required and approved by the Fire Department at the time of original certificate of occupancy are acceptable. No additional fire extinguishers are required for: a. General admission assemblies b. General session assemblies c. Banquets assemblies d. Theater seating assemblies 2. Additional fire extinguishers may be required by the Fire Department for placement in an exhibition hall assembly to provide: a. Access within 75 feet of travel b. One extinguisher per each 11,250 square feet. c. One unit of Class A rating per 11,250 square feet d. Special hazards, i.e. hot works and cooking shall be provided with a fire extinguisher suitable for the hazard. A Class K fire extinguisher shall be provided for demonstration cooking. 3. Minimum 2A10 BC rated extinguishers shall be provided. 4. Fire extinguishers and fire hose cabinets shall not be obstructed. Page 5 of 11

Cooking: Temporary exhibition and display cooking is only permitted within the limitations given below. Production cooking operations require food preparation within permanent commercial cooking facilities with permanent commercial cooking ventilation. Cooking operations are permitted with the following limitations: 1. All cooking appliances shall be listed or approved by a nationally recognized testing agency i.e. Underwriters Laboratories, Inc., Canadian Standards Association (formerly American Gas Association,) etc. 2. All cooking equipment is to be operated according to the manufacturers recommendations, UL listing and operating instructions. Equipment recommended for outdoor use shall not be used indoors. 3. All multiple-well cooking equipment using combustible oils or solids and cooking surfaces i.e. grills that exceed 288 square inches that produces grease laden vapors shall be provided with a fire extinguishing system installed according to NFPA17A and an exhaust duct system complying with the currently adopted Mechanical Code. 4. All single-well cooking equipment (deep fat fryers), operations using combustible oils or solids shall meet all of the following criteria: a. Metal lids sized to cover the horizontal cooking surface are to be provided. b. The cooking surface is limited to 288 square inches (2 square feet). c. The equipment shall be placed on a noncombustible or limited combustible surface. Examples include concrete floors and Fire Resistance Treated (FRT) plywood. The noncombustible surface must extend three (3) feet in front of the fryer. d. The fryer is to be separated from all other equipment by a distance not less than 24 inches. e. These cooking displays must be separated from all other combustibles by a distance not less than 10 feet. f. The volume of cooking oil per appliance is not to exceed 3 gallons. g. The volume of cooking oil per booth is not to exceed 6 gallons. h. Deep fat fryers shall be electrically powered and have a shut-off switch. 5. Other appliances for exhibition cooking shall also be limited to 288 square inches in area. Examples are induction cook tops, ranges, electric warmer, single burner ranges, multiple burner ranges. Page 6 of 11

6. A minimum of one (1) Class-K fire extinguisher shall be provided within 30-feet of each deep-fat fryer and each grill or other appliance producing grease laden vapors. 7. A minimum of one (1) Class 2A-30BC fire extinguisher shall be located within each booth with additional or other display cooking such as baking, sauté, braising, stir fry, convection cooking, warming of food, and all other like applications. 8. Solid fuels including charcoal and woods, i.e. hickory, mesquites are prohibited within exhibit halls. 9. LP-gas or butane used for displays and demonstrations is limited to cylinders or canisters not exceeding the nominal 5-pound size (12 lbs water capacity), maximum 2 per booth. Additional cylinders or canisters must be located 20 feet apart.. Banquet Serving: Banquets are to follow the same guidelines as Exhibition and Display Cooking. Food Warming: This operation at exhibitions is limited to maintaining the temperature of pre-cooked food or beverages at or below 200 º F. Flame devices utilized for food warming shall be separately permitted as open flame devices. Such devices shall be for stationary use only and shall be enclosed or installed in such a manner as to prevent the flame from contacting any combustible materials. Such flame devices utilized for food warming shall not be located in unoccupied rooms or otherwise left unattended. Chemical-heat (Sterno) is allowed in occupied rooms or halls during the permitted hours of the event. It shall be used in accordance with the manufactures instructions. Mobile warming carts, using chemical heat may be used in accordance with the manufactures instructions. Chemical heat may not be used in warming carts that are not manufactured for chemical heat devices. Decorations and Exhibit Booths: All decorative materials including (draperies, artificial plants, etc.) used for construction or decoration shall be flame retardant and flame certificates shall be provided. 1. Flame resistance certifications shall be available to the Clark County Fire Department Inspectors so that all hanging textiles perimeter or subdividing curtains can be judged as being flame resistant. Decorative textiles, drapes, curtains and the like shall be flame retardant as tested by NFPA 701. 2. Textiles, drapes and the like shall not obstruct fire alarm strobes, fire hose cabinets, fire extinguishers or any other fire safety equipment. 3. Table linens are not regulated by this guideline. 4. Foam plastics, other than poster boards, shall not be permitted. CCFD will consider foam plastics complying with the currently adopted Building Code. A separate Fire Page 7 of 11

Protection Report demonstrating compliance with the Building Code is required for foam plastics. 5. Fire resistant foam board signage, not greater than 1/2-inch in thickness, is acceptable. Booth Construction: Booths construction materials (except for foamed plastics) are not regulated. Covered booths exceeding 1,000 square feet shall be provided with interior automatic sprinkler protection. A separate permit application shall be submitted for such structures. Hot Works: A separate submittal for Hot Works Event Permit is required for exhibition welding, demonstration oxy-acetylene welding, soldering, brazing, glass-blowing and the like. Electric spot welding, arc, TIG and MIG welding etc. may be allowed according to an issued permit. Small scale, jewelry welding may be allowed when permits are issued. Full scale oxy-acetylene welding will not be permitted in an exhibition assembly. A blanket permit covering multiple operators is acceptable for a single exhibition space. All exhibitors and their hot works equipment and description of their demonstration must be submitted. See the Fire Department Fee Schedule for the number of exhibitors allowed in a single permit. The hot-works permit submittal shall include a description of the operations and fire safety precautions. CCFD will determine if the operations and precautions are acceptable and either issue or deny the permit. Page 8 of 11

APPENDIX A INFORMATION REQUIRED ON TEMPORARY ASSEMBLY PLANS The following information shall be in provided on submitted plans: Location of fire appliances, such as fire extinguishers, fire hose stations, etc. Exit widths of all exits shown for room. Widths of all aisles and cross aisles. Location of stages, curtains, and drapes. Length and width of room to be used. Location of each exhibit booth Location of stages, platforms, vehicles and other fixed obstructions Location of camera platforms Location of sound booths Indicate whether pyrotechnics and flame effects will be used. Indicate whether open flame(s) and candles will be used. Locations of all multi-level booths (if applicable). The following block shall be included on a plan. 1. Contact person and their telephone number. 2. Name of the event 3. Type of the event. 4. Name of the room to be used. 5. Total area of the room with the dimensions in ft. 6. Usable square footage of the room with the dimensions. 7. Maximum occupant load and calculations and conversion factors used. 8. Required exit capacity (inches or linear feet) and calculations and factors used. 9. Actual exit capacity 10. Move-in and Move-out dates of the event. 11. Total number of tables, chairs and booths along with their sizes and seating arrangement. Page 9 of 11

APPENDIX B DEFINITIONS The following are special definitions within the context of this Guideline: Assembly: For the purposes of this guideline, a gathering of 300 or more persons for a specific event. Booths, single and multi-level: Assembled display structures for displaying sales literature and product demonstrations. Multi-level booths are characterized as having human occupancy above the floor or ground. Class A Fire Extinguisher: Fire extinguisher used for ordinary combustibles (i.e. wood and paper); the fire extinguisher is also assigned a rating number. Class K Fire Extinguisher: Fire extinguisher that has been subjected to special tests on cooking appliances using combustible cooking media. Cooking: Heating food products to at least 200ºF by baking, boiling, deep fat frying, sautéing, etc. Event Operator: Organization or entity responsible for sponsoring the event. Exit: Persons traveling through an exit are considered safely away from a hazard such as a fire. Therefore exit has a special definition in the context of building and fire codes as follows: That portion of a means of egress system which is separated from other interior spaces of a building or structure by fire-resistance rated construction and opening protection as required to provide a protected path of egress travel between the exit access and exit discharge. Exits include exterior exit doors at ground level, exit enclosures, exit passageways, exterior stairs, exterior exit ramps and horizontal exits. Exit Access Travel Distance: Distance from any point within a building to an exit. Grease Laden Vapors: Significant cooking vapors that can collect on adjacent and over-head surfaces from deep fat frying, grilling of fatty meats and the like. Hot Works: Working metal, glass, jewelry, or other materials by brazing, soldering, flames, grinding, producing sparks or welding. LP-gas: Compressed liquid petroleum gas consisting mainly of propane with a lesser amount of butane and pentane. Page 10 of 11

Master Egress Plan: The plan approved by Clark County Development Services (the Building Department) that established the egress systems for buildings and venues. The Master Egress Plan establishes a base egress system and typically will not include all temporary use conditions. Means of Egress: System used to exit from a building including the exit access, exit and exit discharge. National Fire Protection Association (NFPA): Major U.S. fire standards promulgating organization. NFPA 701: Fire test standard for fabrics used to determine if hanging textiles and fabrics are acceptable for use in assembly occupancies. The full title is Standard Methods of Fire Tests for Flame Propagation of Textiles and Films. Permit and Service Fee Schedule: Schedule of fees associated with obtaining required operational permits associated with the assembly event. Pyrotechnics: Controlled exothermic chemical reaction that are timed to create the effects of heat, gas, sound, dispersion of aerosols, emission of visible electromagnetic radiation, or a combination of these effects to provide the maximum effect from the least volume. Sterno: Trade name for a formulation of gelled denatured alcohol fuel commonly used to warm food and beverages. Vehicle Display: Display of normally functional motor vehicles, modified for display during assembly occupancy. Warming (food): Use of cooking media at temperatures of 200ºF or less. H:\Guidelines\ASSEMBLY NOV 09\Assembly Guidelline Industry Comments May 24, 2010.doc Page 11 of 11

TEMPORARY PERMIT - Application Clark County Fire Department Fire Prevention Bureau 575 E Flamingo Rd Las Vegas, NV 89119 Phone (702) 455-7100 Fax (702) 735-0775 Website: www.clarkcountynv.gov/depts/fire Email Address: permits@clarkcountynv.gov --------------------------------------------------------------------------------------------------------------------------------------- $75.00 minimum application fee is due at time of submittal. Fee is payable in exact cash, check/money order (drawn from US bank payable to CCFD), or FD escrow account only. Application Date: Payment Type: Cash Check -or- FD Escrow Account #: (Please circle one) CCFD Code Enforcement Case No.: (If applicable) Building Permit No.: (If applicable) Amusement Buildings - Temp (FABT) Asbestos Removal - Temp (FART) Candles and Open Flame - Temp (FDCT) Carnivals & Fairs Temp (FCFT) Christmas Tree Lots - Temp (FCTL) Covered and/or Multi-Story Booth - Temp (FDMB) Exhibits & Trade Shows/Special Events - Temp (FDET) Sq Footage: Explosive Materials Temp (FEMT) Number of Magazines: Fireworks Booth - Temp (FFBT) Fireworks/Pyrotechnics Display Outdoor Temp (FFDO) Device Count: Fireworks/Pyrotechnics Proximate Indoor/Outdoor Temp (FFPT) Device Count: Please check appropriate box PERMIT INFORMATION Flame Effects Temporary (FFET) Mobile Fueling Site Temp (FMFT) Mobile Fueling Vehicle Temp (FMVT) Hazardous Materials Temp (FDHT) Hot-Works Fixed Temp (FHFT) Hot-Works Mobile Temp (FHMT) Hot-Works Combination Mobile/Fixed Temp (FHWT) Liquid or Gas-Fueled Vehicles or Equipment in Assembly Area - Temp (FLQT) Liquefied Petroleum Gases Temp (FPGT) Open Burning Agricultural Temp (FOBT) Places of Assembly Temp (FDAT) Spraying or Dipping Temp (FSDT) Temporary Membrane/Bldg Structure/Tent/Canopy (FTTT) Sq Footage: Plans: New Revision Correction Application # (If applicable): (Please circle one) Note: If plan is a revision or a correction then the original application number must be provided. Expedite: Yes or No Municipal Project/Property: Yes or No APN: Venue Address: Bldg-Suite#: Name of Venue: Exact Location within Venue: (i.e.: Name of ballroom, hall or parking lot location) Name of Event: Event Move-In Date: Event Move-Out Date: ** Date Event Will Be Set Up For Inspection: ** On-Site Inspection Contact Name: Cell #: APPLICANT INFORMATION Submitting Company Name: Mailing Address: Bldg-Suite #: City, State, Country, Zip Code: Company E-mail Address: Company Phone #: ( ) - Applicant Phone #: ( ) - Ext: Company Fax #: ( ) - Fax #: ( ) - Applicant E-Mail Address: Applicant Name and Title Applicant Signature P:\Finance\Fire Prevention\Application Forms\FD AppTemporaryPermit.2010.doc Created 04/10/10 Revised 01/27/11

Track your PLAN REVIEW STATUS online! 1. Go to: http://dsc2g.co.clark.nv.us/click2govbp/selectpermit.jsp Enter your application number in fields provided & click on Submit. Click on PLAN TRACKING STATUS. Click on FD PLAN TRACKING. This will open the Action History table related to your application and plan review. All action logs are listed in date order and may be opened to review any comments entered by Fire personnel. Just click on the desired Action Description to view comments. When the most recently dated action log FD READY FOR PICKUP or FD READY FOR MYLAR has been entered by Fire personnel, you must check to see if any additional fees are due. If additional fees are due, based on our escalating fee schedule, payment must be made when plans are picked up or Mylar s submitted for signature. 2. To determine if additional fees are due: Click on VIEW APPLICATION FEES. This will open the Application Fees summary related to your application and plan review. The Fee Description listed is your permit type, the Amt Charged is the total fee assessment for the plan review (or the standard permit fee), and the Amt Due is the outstanding fee balance. 3. If there is an outstanding fee balance, you may view the related comments that explain what the additional fee assessment is for. Click on PLAN TRACKING STATUS. Click on FD PLAN TRACKING. Click on the most recently dated action log FD READY FOR PICKUP or FD READY FOR MYLAR. This will open the Plan Tracking Status action log Comment related to your application and plan review. Again, all outstanding fees must be paid when plans are picked up or Mylar s submitted for signature. New plans, revisions and corrections, will not be accepted if there are outstanding fees due for a related application. Note: If your plans are approved and there are no outstanding application fees due then you re ready to schedule your inspection. ** If you d like to visit just the Fire Department website please go to ** http://fire.co.clark.nv.us/home.aspx P:\Finance\SunGard.Naviline\App.Plan Status\Track your PLAN REVIEW STATUS online.doc