XSD Dry Cabinet

Similar documents
Long Term Storage Cabinet

XSD Dry Cabinet. Outstanding performance. The XSD series has an outstanding performance for drying moisture sensitive components and pcb s.

HSD Dry Cabinet

XSD Dry Cabinet

HSD Dry Cabinet. Outstanding performance

HSD Dry Cabinet. Outstanding performance

XSD Dry Cabinet

MSD Cabinets. Modular Dry Cabinet. Outstanding performance

SDR Dry Room. Outstanding performance

SD Storage Cabinet. Outstanding performance

SD Storage Cabinet. Outstanding performance

SD Storage Cabinet

SDB Storage Cabinet

Drying Cabinets and Vacuum Machines for Moisture Sensitive Components

Drying Cabinets and Vacuum Machines for Moisture Sensitive Components

A Member of the ASYS Group A Member of the ASYS Group PRODUCT CATALOGUE

Constant climate chambers

Constant climate chamber with humidity

METAL SHARK COMBI Flat metal detector for textile and non-woven products. Metal sensitivity from Fe 0,3 mm

Revolution of Low Humidity Storage!!

Laboratory Air circulated Refrigerator/Deep Freezer TC Two-door (2 independent temperature ranges)

Constant climate chambers

Environmental simulation chamber for complex alternating climate profiles

Constant climate chambers

Laboratory Deep Freeze Storage Cabinet TC 230 Air circulated

Specifications Minimum Typical Maximum Unit

Constant climate chamber with ICH-compliant illumination

Drying and heating chambers

Medical Air circulated Refrigerator TC (2 independent temperature ranges), also in accordance with DIN 58345

Ultra low temperature freezers for long-term storage at -86 C UF V 500, UF V 700

Constant climate chambers. KBF 240 (E5.2) - Constant climate chamber. Performance features and equipment:

ULTRA-LOW HUMIDITY STORAGE CABINETS 1, 3%RH

Plasma Freezer with air circulation TC 516 acc. to DIN 58375

KMF Environmental test chamber for constant climate

Chromatographic Air circulated Refrigerator, two-door TC 603

FITOCLIMA 600 & 1200 STABILITY

Model MKFT 115 Dynamic climate chambers for rapid temperature changes with humidity control and extended low temperature range

Climate chambers with illumination and humidity The BINDER KBWF series shines with its

External Dimensions: B = 750 mm D = 700 mm H = 2100 mm. Internal Dimensions: B = 600 mm D = 580 mm H = 1270 mm. Temperaturerange: 2 C to 20 C

EC 160 CO 2. Incubator

Internet. Climate rating definitions. Customer service.

FITOCLIMA 600 & 1200 STABILITY

973 Dew Point Mirror. Portable Industrial Chilled Mirror Hygrometer. Typical applications: REFLECTING YOUR STANDARDS

Constant climate chambers

Compressed air quality meas. according to ISO 8573 Residual oil content - particles - moisture

Model MKFT 115 Dynamic climate chambers for rapid temperature changes with humidity control and extended low temperature range

External Dimensions: B = 600 mm D = 630 mm H = 2000 mm. Internal Dimensions: B = 451 mm D = 430 mm H = 1598 mm

573 Dew Point Mirror. Industrial Chilled Mirror Hygrometer. Typical applications:

ULTRA.GUARD ultra low temperature freezer

Multi-Lab REFRIGERATORS Frigidere medicale

Model C 170 CO 2 incubators with hot air sterilization

ULTRA-LOW HUMIDITY SEIKA. ERC Co., Ltd. ULTRA-LOW HUMIDITY STORAGE CABINETS 1%RH. Conforms to IPC/JEDEC J-STD-033D and IPC-1601 Guidelines.

Model CB 220 CO 2 incubators with hot air sterilization and heat sterilizable CO 2 sensor

STABILITY. Stability Storage Chambers & Environmental Stability Rooms

portable gas analyser

CO₂ incubators. C CB series

Constant climate chambers

Dräger Polytron Pulsar 2 Open Path Gas Detector

Constant climate chambers

Laboratory Refrigerator/Deep Freezer TC 802

CLIMATIC TEST CHAMBER CTC / TEMPERATURE TEST CHAMBER TTC 100 % AtmoSAFE: In Memmert environmental

Chromatographic Air circulated Refrigerator, two-door TC 603

Revolution of Low Humudity Storage!!


Duct Humidity and Temperature Transmitter. Features. IP65 protection. Ordering

Dew point. Special features: Dew point monitoring DS 400. Technical data DS 400. Technical data FA 510

Dew point set DS 400

FITOCLIMA 600 & 1200 PHARMA

Walk in Steam Curing Chamber for Concrete Application. Detailed Working Specifications

INSTRUCTION MANUAL ESDA Cabinets with display

Plant growth chambers

Huminator II. Precision Humidity Generator. ww.testo.in

Refrigerators and freezers Research and laboratory 2018

STABILITY ICH. ICH Stability Tests

Termaks AS Lien 79, N-5057 Bergen, Norway Tel: Fax: Web:

Duct Humidity and Temperature Sensors 0-10 Vdc or 4-20 ma Outputs Passive sensor PT1000, PT100 NTC, NI1000 etc. Features. IP65 protection.

Industrial Freezer Sales A division of IDS 5311 Derry Avenue Building D Agoura Hills CA Phone (818) Fax (818)

NEW GENERATION. Efficient use of valuable space INCUBATORS

Refrigerated Incubators / Environmental Testing Chambers

Standard-Incubators. Avantgarde.Line BD BF series. Classic.Line B BD BF series. Solid.Line BD-S series

Using the Model 1500 Portable Chilled Mirror Hygrometer

Accessories, interfaces, sensors and complete solutions.

HUM-M2 Humidity Sensor Module Description

Drying and heating chambers. Series ED FD FED FP M

EL-USB-1-LCD Temperature Data Logger with LCD

Technical Description. Laboratory Climate Test Chamber. System Weiss. Mat. No.: Type WKL 34/40

incubator, the best in its class

Refrigerated Incubator Model and Operating Instructions

Model KMF 720 Constant climate chambers with expanded temperature / humidity range

EL-USB-TC Thermocouple Data Logger with USB Interface

ORDERING INFORMATION FEATURES EL-WIN-USB (CONTROL SOFTWARE) Maximum Speci cations Typical Minimum Unit

EasyLog Data Logger Series

EL-USB-CO300 Carbon Monoxide (CO) Data Logger with USB Interface

Environmental Chambers

Tinytag Plus LAN Data Logger with Temperature & Relative Humidity Probe (-25 to +85 C/0 to 100% RH) Standalone. Tinytag Connect

Refrigerators and freezers Pharmacy and laboratory 2016

DFM. flow pressure temperature MULTI PARAMETER DIGITAL MASS FLOW METERS. Totalizer. Interface

R9900. Model. Instruction Manual. Indoor Air Quality Meter. reedinstruments. www. com

CO₂ incubators. C CB series

THX-DL Data Logger USER & INSTALLATION MANUAL V

Transcription:

XSD-701-52 Dry Cabinet Outstanding performance The XSD series has an outstanding performance for drying moisture sensitive components and pcb s. The dynamic drying unit of the 5000 series reaches very reliable low humidity values of 0,5% RH and automatically regenerates if necessary. As a result of an insulated double metal sandwich construction a precise temperature of 60 C can be reached with a very low power consumption. A radial fan and heater supports the drying process and realizes an equable temperature and moisture level in the cabinet. The relevant process data is obtained by use of an accurate Rotronic sensor.

Features User friendly handling ESD features Insulation Data logging Online functionality Interior lighting Door & humidity alarm buzzer Leveling out Lockable doors Sliding shelves U 5000 series drying unit Rotronic sensor Display with easy menu structure Norm (IEC 61340-5-1) ESD stainless steel body (<10 3 Ohm/sq). Conductive glazing (in- and outside 10 3 Ohm/sq). 60 mm sandwich construction with Polyurethane Integrated data logger over Sensor with standard 2000 measuring points (optional software is required). Interface and data logging through standard Ethernet interface Compatible with new MSL 2.0 software Low power consumption LED lighting Longer door openings are detected, high RH levels are detected Adjustable legs Every door can be locked separately with a key. In height adjustable sliding shelves (5 pcs) 0.5% RH, made in Germany Precision sensor, accuracy +/- 0,8 % RH, +/- 0,3 C Power cord 5 meter with IEC plug Benefits Drying time (see reference table) Recovery time after door opening Temperature stability Temperature setting Energy saving consumption Network IPC European Quality Maintenance Fast drying time, Level 3 component, <1,4 mm = 18 hours (60 C / 1% RH) < 6 minutes The same temperature level throughout the drying cabinet as a result of the use of a radial fan in combination with ventilation and heating canal in an insulated sandwich construction. Accuracy +/- 2 C Heating up to 60 C As a result of a Dynamic dry unit, sandwich construction with insolating Polyurethene. Standard ethernet interface According to IPC-Jstd 033C Made in Germany Easy to service, low maintenance

Technical Data Cabinet External dimensions: (W x H x D) 700 x 1930/2110 x 808 mm Internal dimensions: (W x H x D) 544 x 1504 x 600 mm Weight: 142 kg Weight on shelf: 50 kg Shelves (WxD): 5 pcs, 535 x 550 mm. Volume: 490 L Electric supply: 230 VAC (120 VAC optional) Power consumption: 450 W/h (60 C) Protection class: class 1, hard grounded Humidity level cabinet: 0,5 % RH can be reached with drying unit U 5002 Sensor accuracy: +/- 0,8 % RH, +/- 0,3 C Temperature accuracy: 60 C, +/- 2 C Technical Data 2-series Display Settings: Language Menu Nominal Value Humidity Nominal Value Humidity Alarm Delay Humidity Alarm (in combination with heater) Nominal Value Temperature (in combination with heater) Temperature Alarm (in combination with heater) Delay Temperature Alarm Doors Alarm Interlocking Manual Regeneration Display: Supply voltage (supplied by drying unit) 24 VAC/DC Input 4 function keys (tactile-touch keys) Display 61 x 33 mm, white, controllable backlight, adjustable contrast Ethernet connection Power consumption at 24 VDC, 40 ma

Technical Data Rotronic Sensor HC2-S Based on the Airchip 3000 Technology use the HygroClip 2 probes can be used for control of temperature and humidity. The HygroClip 2 probes can be configured with the ROTRONIC HW4 software and share the following features: Measurement of relative humidity and temperature. Data recording of up to 2000 relative humidity and temperature value pairs. Programmable automatic sensor test with fail safe mode and sensor drift compensation. Technical Data dry-unit U 5000 series Dehumidifying performance: 120 g/h max. Minimal humidity 0,2% RH Dehumidifying Temperature 10 60 C Electric supply: 230 VAC (120 VAC available) Dimensions (L x B x H): 487 x 487 x 150 mm Weight: 21 kg

Free Totech viewer: Writing of climate data, door openings and alarms to SD card Transfer of data through Ethernet to PC (history data) User-friendly display of all relevant data Data processing in MS-Excel Seamless documentation Excellent process safety

Performance test Test conditions Instrument: Vaisala. Type of dew point sensor: Vaisala drycap 180M Accuracy of dew point sensor: ± 0,2 C at + 20 C (+ 68 F) Location of sensor: In the direct surrounding of cabinet sensor Ambient conditions: Humidity 50 ± 5% rh, 25 ± 2 C, Pressure 994 ± 20 hpa. Dooropenings: 2 dooropenings, 15 sec. (average RH 0,70%)

Technical Drawing XSD-701-52 Dimensions mentioned in mm. Number of different types of shelves that can be mounted in cabinet: Number of shelves (47000141) 5 6 7 8 9 10 11 12 13 14 15 Distance (in mm) between shelves if equaly devided 260 210 165 165 115 115 70 70 70 70 70 Remaining space between top shelf and top cabinet 235 190 235 40 235 90 430 330 235 140 40 Number of drawers 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 Remaining space in mm 1366 1270 1174 1078 982 886 790 694 598 502 406 310 214 118 22

Technical Drawings Reel rack 20014005 25 502 25 Reel rack formation, 38 reels of 8mm can be placed in 1 reel rack, totally 152 reels. Short strip 553 Long strip Drawer divider system Drawer formation

Technical Drawings Shelves formation Different Feeder racks possible Honeycomb systems 2 pieces of honeycomb system 1 piece of honeycomb system

Options SMD Reel rack with reel supports, L x W = 530 x 265 mm incl 18 reel supports; Item number 20014005 Reel support, additional reel supports for 20014005: Item number 20014201 Door release pedal, These foot pedals enables you to open the doors keeping your hands free, Item number 47000146 Humdidity alarm signal Lamp, two-color, (orange/green or red/green), magnetically fixed, providing optical signals on operational states and exceeded limit values. Operates on 24 V. Item number orange/green 20016030. N2 auto flow system, The Auto-Flow-System is developed to use in combination with a Totech drying cabinet. The device is used for the quick removal of moisture in the cabinet after the doors has been opened. The drying process is realized by using nitrogen (N²), which is add automatically after the doors have been closed. (by means of adjustable timer function) Item number 22613066

Options Additional Sliding Shelves, stainless steel sliding shelf, (without rollers) Item number 47000136 Additional Sliding Shelves, stainless steel sliding shelf on metal rollers, 100% extractable Item number 47000141 Drawer, stainless steel drawer Item number 47000127 Divider system drawer, Stainless steel divider system which enables you to create compartments with a minimum measurement of ± 2,5 x 2,5 cm or a multiple of 2,5 cm. A standard set contains 5 long strips (553 mm) and 5 short strips (502 mm). Item number 47000129 Cover plate for XSD shelves, prevent small items to fall through Item number 47000132

Options Honeycomb system, Flexible stainless steel storage system for IC Tubes components & PCB s. The width of the compartments is adjustable before installing the system in the cabinet. The number of compartments variates from 17 till 170. In total 4 systems can be Installed in a cabinet. Item number 20050100 X Feeder System, This feeder rack is suitable for Siemens X Feeder systems. Sold in combination with reel rack Item number 46204004 S Feeder System, This feeder rack is suitable for Siemens S Feeder systems. Sold in combination with reel rack Item number 46204009 HygroClip 2, Probe with maximum accuracy for all climate measurements Item number 470000027 Exchange calibrated sensor: Item number 47000040 Humidity calibrator Hygropalm 22, precision measuring device for calibrating sensors Set including Hygroclip sensor, case and cable: Item number 20001019 Hygropalm only: Item number 20001016

Options MSL 2.0 software for 1000 components, Software solution for the monitoring of moisture sensitive components and their MSL States during storage and processing in the production. With the software the exact drying state individually for each component is monitored and displayed. One of the possibilities is that it can read out multiple HC2-S sensors. To adjust storage conditions,picking of stock, removal of used parts & more stock control. Here, a complete history for each component is traceable up to the full processing. The evaluation of the drying conditions is based on the requirements of the IPC / JEDEC J-STD-033C directive. Item number 20010036 MSL software upgrade with additional 1000 components, Upgrade to monitor an additional 1000 components Item number 20010037 Rotronic datalogger set, Including Software HW4-E-V3 and Cable AC3006 Item number 47000580 Sensor accuracy: +/- 0,8 % RH, +/- 0,3 C V11.15