PRODUCT CATALOGUE Norröna

Similar documents
IEC ; EN ; DIN VDE ; CEI 20-37/2-1 ; BS * No Corrosive Gas Emission

Caledonian Flame Retardant Coaxial Cables

FIRE RESISTANT CABLES

Flame Retardant Overall Screened Instrumentation Cables (multicore)

IEC UNE DESIGN. 1. Conductor. 2. Insulation. Cross-linked polyethylene (XLPE) 3. Outer sheath. Flexible PVC, black colour.

Note: Asterisk ** denotes that the standard compliance is optional, depending on the oxygen index of the PVC compound and the cable design.

Caledonian Fire resistant Coaxial Cables

Shipboard & Offshore Cables

Compact Module. Category 6A FTP Cabling System 1.1

Catalogue Telecommunication Cables INTRODUCCIÓN

High Performance LSZH Fire Resistant Cable

IEC ; EN ; DIN VDE ; CEI 20-37/2-1 ; BS * No Corrosive Gas Emission

600/1000V XLPE Insulated, LSZH Sheathed, Double steel tape Armoured Power Cables (3 Cores)

AFIREFENIX SZ1-K 0,6/1 kv PH120 (AS+)

INTRODUCTION. Our diverse range of world-class Specialty Insulated Wires and Cablesinclude: LV Cables -

Multi-Core Fire Resistant Cable

Caledonian fire Resistant signal & Data cables

600/1000V SR Insulated Flexibles Control Cables (2-4 Cores & Multicores)

Telecommunication Cables

Catalogue Power Cables

SPECIAL ELECTRICAL AND OPTICAL CABLES

OFFSHORE CABLES. Top Cable Central Headquarters. Leonardo Da Vinci, number Rubí (Barcelona) Spain

Power Cables. Introduction 3 RV 4 RVMV 5 RVSV 6 RVFV 7. ELECWIRES 2 Page

DNVGL-CP-0401 Edition February 2016

Photovoltaic Cables EN H1Z2Z2-K

CATEGORY 6A FTP RJ45 SOLUTION

DNVGL-CP-0399 Edition March 2016

The Quality Connection. BETAflam Fire Resistant Safety Cables

Double insulated, electron-beam cross-linked, halogen free photovoltaic wire sunlight resistant. Single conductor, flame retardant insulation.

DNVGL-CP-0402 Edition February 2016

Catalogue. Instrumentation & Control Cables

Table of Contents. TELE-FONIKA KABLE SA (DMCC Branch). 4 TELE-FONIKA Kable Group 6 FLAME-X 950 SERIES 1 11 FLAME-X 950 SERIES 2

CABLES FOR ALARM AND SAFETY SYSTEMS

CIR CRUSH & IMPACT RESISTANT OIL & GAS CABLES

SAS Security and Alarm Safety Cables

Introduction.

BS /1000V XLPE Insulation LSZH Sheath Cables

CIR CRUSH & IMPACT RESISTANT ARCTIC GRADE OIL & GAS CABLES

Firetuf OFC-UT-CST Fire resistant Armoured Central Tube Cable, variant in red

Traction Cable Radox 3 GKW

OIL & GAS INDUSTRY OTHER INDUSTRIES

UNIKA Universal Cable Cable Specialist

Copper LAN cable. This specification describes the general requirements for AMP NETCONNECT* copper LAN cable.

CIR AG Power Cables. CIR AG Control Cable. CIR Type VFD Cable. CIR AG Ratings & Approvals. n UL Listed as Type TC-ER n UL Listed as TC-ER-HL (E123629)

600/1000V XLPE Insulated, PVC Sheathed, Armoured Power Cables (Multicore)

fire resistant cables

Firetuf Cables ZERO HALOGEN, LOW SMOKE (0HLS ) CABLE

Firecel Safety Cables

Firetuf Cables ZERO HALOGEN, LOW SMOKE (0HLS ) CABLE

INTERNATIONAL STANDARD

S Low loss coax cables with foamed PE

Data sheet OpDAT breakout cable 12x1 OM4 - bend insensitive, class Dca s1 d1 a1

Lloyd s Register Type Approval System Test Specification Number 3

Total Fire Solutions. Includes BS 8519 and the updated BS :

Flexible Power Cable DLO

Data sheet OpDAT universal cable 1x24 OM4 - bend insensitive

PHOTOVOLTAIC CABLES. Photovoltaic Cable 2000V/1500V Photovoltaic Cable 2000V/1000V

TYPE APPROVAL CERTIFICATE

CORFLEX. TYPE MC-HL & MV-105 or MC-HL OIL & GAS CABLES

Fire alarm cables. for highest safety requirements TRADITION INNOVATION PASSION

CAT5E DIRECT BURIAL (FLOODED CORE) 24AWG, UTP, 4 PAIR, SOLID 1000 PULL BOX /CMXF

Flexflame. Arctic Grade Cables for Extreme Conditions. Photo: Sakhalin Energy Investement Company Ltd.

Low Smoke Zero Halogen

Flame Retardant EP/CPE POWER, CONTROL & INSTRUMENTATION CABLES

Power Control Cable Iec

Industrial Fiber Optic Cables, LSZH Corrugated Armored Cable, Fibers

Firetuf OFC-UT-CST Fire resistant Armoured Central Tube Cable, variant in red

Data sheet OpDAT mini breakout cable 24x1 OM4 - bend insensitive

Core identification code. J-YY...BD Indoor Cable. J-YY...BD Indoor Cable. VDE 0815 Mutual capacitance. J-YY...BD Indoor Cable. Cu conductor 0.

Cable technology for highest safety requirements

Havells Fire Survival Cables

Comtran Cable. Hub-LINK Cables for Transit Applications

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

FIRE PERFORMANCE CABLE

BS EN :2004. Test On Electric And Optical Fibre Cables Under Fire Conditions. WF Report Number. Date: 14 th November 2008.

CONTENTS. Introduction Customer Service BS codes of practice BS Fire Performance Cable Selection Guide... 7

CORFLEX TYPE MC-HL POWER, CONTROL & INSTRUMENTATION CABLES

ENHANCED FIRE PERFORMANCE CABLE

Fire Resistant Cables

FIRE RESISTANT CABLES FP300

INTERNATIONAL STANDARD

UV RESISTANT ACCORDING TO HD 605 RULE

Energy Division Heat-shrinkable joints for halogen-free, flame-retardant and fire-resistand cables up to 1 kv

INTERNATIONAL STANDARD

PERFORMANCE POLYMER SOLUTIONS

The Quality Connection. BETAflam safety cables for highest demands

INTERNATIONAL STANDARD

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

FUMEGUARD TM QUALITY APPROVED CABLES. Cables Limited MADE IN IRELAND SINCE 1934 IDH CABLES LIMITED LOW SMOKE HALOGEN FREE CABLES

Electrical test. Determining resistance of conductors by means of using DC four-wire connection measurement

LV FIRE RESISTANT CABLES

C6 Premium. C6 Premium Copper Systems from Infinique is premium performing Class E / Category 6 Data Communication

Brand Portable Power Cord & Control Cable Solutions

Caledonian. FIREFLIX ire Resistant Coaxial Cables

Belden Infinity C-TC+ Cables for Extreme Flexing

Multipurpose Cables (indoor/outdoor), Multipurpose central tube cable (maxibundle) with glass yarn armouring A-DQ(BN)H 4-24

LSOH Flexible Cables

FIRE RESISTANT CABLES FP400

MEDIUM VOLTAGE CABLES INSTRUMENTATION CABLES RUBBER CABLES FIRE RESISTANT CABLES

CMZH Low Smoke 0-Halogen Flame- Retardant Mass Transit Tag

Transcription:

PRODUCT CATALOGUE Norröna WWW.SCANKAB.COM

Table of contents MARINE AND OFFSHORE CABLES 1 TOXFREE XZ1-K (AS) - 0.6/1 kv 1 TOXFREE MARINE XO2TCuZ1-K (AS) - 150/250 V 5 4x2xAWG 24/1 CAT6 S/FTP LSZH-SHF1 - Black 7 TOXFREE XZ1-K (AS+) IEC 60331-0,6/1 kv 10

Ship cables - halogen free TOXFREE XZ1-K (AS) - 0.6/1 kv Application: TOXFREE XZ1-K (AS) is a series of unique toxfree installation cables. The cables are designed as exible installation cables. They are suited for all use in street lights, public places, power stations, industry and building installations. They are also very suitable for installations where exible connections are needed such as in a motor, generator and similar. Suitable for bricking. The cable is double insulated. Construction: Conductor: Electrolytic annealed Cu, class 5 Insulation: XLPE Conductor color: According to HD 308 Please notice that dimensions marked with ** are with white numbered conductors Inner sheath: Thermoplastic polyole n (TPO) Outer sheath: Extra exible halogen free compound, meter marked, UV resistant, black Technical data: Working temperature: -15 C to +90 C Rated voltage: 0.6/1 kv Bend radius: <25 mm 2 4 x cable diameter >25 mm 2 6 x cable diameter Technical comments: Current value A is at 45 C Approvals: IEC 60092-353, IEC 60332-1, IEC 60332-3-22, IEC 60754-1, IEC 60754-2, IEC 61034-1, IEC 61034-2, IEC 60092-351, CE, RoHS, ABS, Bureau Veritas, DNV, Lloyd's Register 1

Ship cables - halogen free TOXFREE XZ1-K (AS) - 0.6/1 kv Properties and installation: For use in cable trays For use in wind turbines Bending radius 6 x cable diameter Fire retardant acc. to IEC 60332-3 For use in switchboards Flame retardant acc. to IEC 60332-1 Flexible Halogen free Can lay in tubes Can be buried Can be immersed into water Low emission of corrosive gases acc. to IEC 60754 Low smoke emission during re acc. to 61034 Max. working temp. +90 C Max. short circuit temp. +250 C Meter marked Environmentally friendly Min. working temperature -40 C Oil resistant Oil and grease resistant Resistance towards oil and chemicals Abrasion resistant For permanent outdoor installation Impact resistance: medium For industrial use For industrial mobile use For use on ships For emergency circuits Withstands freezing Withstands moisture Outdoor decommissioning UV-resistant Water resistant Suited for public places Suited for wall attachment Suitable for bricking 2

Ship cables - halogen free TOXFREE XZ1-K (AS) - 0.6/1 kv SKU EAN Dimension (mm²) Current Value (A) Winding Diameter (mm)* Weight (kg/km)* 64001002 5704403042340 1x2,5 25 D./Cut 5,4 45 64001004 5704403042357 1x4 35 D./Cut 5,9 61 64001006 5704403042364 1x6 46 D./Cut 6,5 81 64001010 5704403042371 1x10 64 D./Cut 7,4 122 64001016 5704403042388 1x16 88 D./Cut 8,6 181 64001025 5704403042395 1x25 117 D./Cut 10,4 271 64001035 5704403042401 1x35 147 D./Cut 11,7 370 64001050 5704403042418 1x50 180 D./Cut 13,4 510 64001070 5704403041428 1x70 233 D./Cut 15,3 704 64001095 5704403041435 1x95 285 D./Cut 17,4 923 64001120 5704403041442 1x120 333 D./Cut 19,0 1157 64001150 5704403041114 1x150 386 D./Cut 21,3 1438 64001185 5704403041459 1x185 444 D./Cut 23,9 1750 64001240 5704403045679 1x240 528 D./Cut 26,9 2283 64001240G 5704403063956 1G240 528 D./Cut 26,9 2283 64001300 5704403062454 1x300 612 D./Cut 29,6 2864 64001400 5704403057443 1x400 823 D./Cut 34,0 3784 64002001 5704403041367 2x1,5 23 D./Cut 8,0 97 64002002 5704403042425 2x2,5 31 D./Cut 9,1 131 64002004 5704403042432 2x4 43 D./Cut 10,2 176 64002006 5704403042449 2x6 55 D./Cut 11,4 234 64002010-2x10 75 D./Cut 13,3 348 64002016 5704403062379 2x16 100 D./Cut 15,1 493 64003001 5704403041060 3x1,5 23 D./Cut 8,9 118 64003001G 5704403041541 3G1,5 23 D./Cut 8,9 118 64003002 5704403041107 3x2,5 31 D./Cut 9,8 156 64003002G 5704403044917 3G2,5 31 D./Cut 9,8 156 64003004 5704403044696 3x4 43 D./Cut 10,9 211 64003006 5704403041190 3x6 55 D./Cut 12,2 285 64003010 5704403041404 3x10 75 D./Cut 14,6 442 64003016 5704403041640 3x16 87 D./Cut 16,8 642 64003025 5704403042456 3x25 110 D./Cut 21,0 1008 64003035 5704403041411 3x35 137 D./Cut 24,0 1363 64003050 5704403042463 3x50 167 D./Cut 27,9 1894 64003070 5704403042470 3x70 214 D./Cut 30,5 2532 64003095 5704403042487 3x95 259 D./Cut 36,6 3397 64003120 5704403042494 3x120 301 D./Cut 40,2 4252 64003150 5704403047673 3x150 347 D./Cut 45,1 5299 64003185 5704403061013 3x185 397 D./Cut 50,7 6495 64003240-3x240 468 D./Cut 57,3 8461 64004001 5704403041077 4x1,5 20 D./Cut 9,7 140 64004001G 5704403042920 4G1,5 20 D./Cut 9,7 140 64004002 5704403041374 4x2,5 28 D./Cut 10,6 185 64004002G 5704403041534 4G2,5 28 D./Cut 10,6 185 64004004 5704403041381 4x4 37 D./Cut 12,1 262 64004006 5704403041398 4x6 47 D./Cut 13,5 351 64004010 5704403041589 4x10 65 D./Cut 16,0 544 64004016 5704403041596 4x16 87 D./Cut 18,7 802 3

Ship cables - halogen free TOXFREE XZ1-K (AS) - 0.6/1 kv SKU EAN Dimension (mm²) Current Value (A) Winding Diameter (mm)* Weight (kg/km)* 64004025 5704403051717 4x25 110 D./Cut 23,7 1271 64004025G 5704403062799 4G25 110 D./Cut 23,7 1271 64004035 5704403041602 4x35 137 D./Cut 25,9 1690 64004035G 5704403062805 4G35 137 D./Cut 25,9 1690 64004050 5704403062812 4G50 167 D./Cut 31,3 2396 64004070G 5704403062836 4G70 214 D./Cut 35,8 3284 64004095G 5704403062843 4G95 259 D./Cut 40,6 4282 64004120 5704403062850 4G120 301 D./Cut 44,8 5391 64004150G 5704403062867 4G150 347 D./Cut 50,2 6748 64004240-4x240 468 D./Cut 63,7 10763 64004240G 5704403062874 4G240 468 D./Cut 63,7 10763 64005001 ** 5704403041084 5x1,5 20 D./Cut 10,4 165 64005001G 5704403041558 5G1,5 20 D./Cut 10,4 165 64005002G 5704403041565 5G2,5 28 D./Cut 11,8 229 64005004-5G4 37 D./Cut 13,3 315 64005006-5G6 47 D./Cut 15,0 431 64005010-5G10 65 D./Cut 17,7 670 64005016-5G16 87 D./Cut 20,8 991 64005025G 5704403063352 5G25 110 D./Cut 29,9 1879 64005035G 5704403063369 5G35 137 D./Cut 33,6 2510 64005050G 5704403063376 5G50 167 D./Cut 34,0 2795 64005070G 5704403063383 5G70 214 D./Cut 38,8 3850 64007001 ** 5704403041091 7x1,5 11 D./Cut 11,4 204 64007002 ** 5704403044702 7x2,5 15 D./Cut 12,5 265 64012001 ** 5704403041626 12x1,5 9 D./Cut 14,3 326 64019001 ** 5704403041633 19x1,5 8 D./Cut 17,3 435 64024001 ** 5704403045013 24x1,5 7 D./Cut 18,8 531 * The values can have small deviations 4

Ship cables - halogen free TOXFREE MARINE XO2TCuZ1-K (AS) - 150/250 V Application: XO2TCuZ1-K (AS) is a highly exible cable for permanent installation on ships and o shore units. The cable is particularly suitable for power circuits where shielding is required, or areas which requires additional protection against possible shock. The cable material is halogen free, has low smoke emission and is re retardant. Construction: Conductor: Electrolytic annealed Cu, class 5 acc. to IEC 60228:2004 Insulation: LSZH XLPE Conductor color: Twisted pair (blue/white), numbered Screen: Overall screen of aluminum. Polyester tape with Cu drain wire. Cu wire braid armour over the collective screen. Outer sheath: LSZH thermoplastic polyole ne SHF1, grey Technical data: Working temperature: -40 C to +90 C Rated voltage: 150/250 V Bend radius: 4 x cable diameter Technical comments: Short circuit temperature: max 250 C / 5 sec. Approvals: IEC 60092-376, IEC 60092-350/351/359, IEC 60332-1, IEC 60332-3-22 cat. A, IEC 60754-1/2, IEC 61034-1/2, DNV, CE, RoHS Properties and installation: For use in cable trays Bending radius 4 x cable diameter Fire retardant acc. to IEC 60332-3 Electromagnetical ly protected Flame retardant acc. to IEC 60332-1 Flexible Halogen free Can lay in tubes Low emission of corrosive gases acc. to IEC 60754 Low smoke emission during re acc. to 61034 Max. working temp. +90 C Meter marked Environmentally friendly Min. working temperature -40 C Resistance towards oil and chemicals For permanent outdoor installation Impact resistance: medium For use on ships Outdoor decommissioning Water resistant Suited for public places Suited for wall attachment 5

Ship cables - halogen free TOXFREE MARINE XO2TCuZ1-K (AS) - 150/250 V SKU EAN Dimension (mm²) Current Value (A) Winding Diameter (mm)* Weight (kg/km)* 61620175 5704403056903 1x2x0,75 17,1 D./Cut 7,2 90 61620275 5704403056910 2x2x0,75 13,7 D./Cut 11,3 150 61620475 5704403056927 4x2x0,75 11,2 D./Cut 13,1 215 61620775 5704403056934 7x2x0,75 9,2 D./Cut 15,9 340 61621075 5704403065950 10x2x0,75 8,6 D./Cut 20,2 470 61621475 5704403060276 14x2x0,75 7,4 D./Cut 21,9 605 61621974 5704403065974 19x2x0,75 6,5 D./Cut 24,9 795 * The values can have small deviations 6

Ship cables - halogen free 4x2xAWG 24/1 CAT6 S/FTP LSZH-SHF1 - Black Application: The cable is used in telecommunication network for transmission of digital and analogical signals up to 250 MHz. Due to its unique design and UV resistance, the cable is suitable for installation in maritime and offshore environments, but it can also be used for industrial use, where demands are made for increased fire safety. The cable is UV resistant, marine approved and paired, individually screened. Construction: Conductor: Insulation: Bare, annealed copper (24 AWG) Cellular PO (1.04 mm) Conductor color: TIA/EIA 568-B Screen: Outer sheath: Braided, annealed tinned copper (55% coverage) Paired, individually screened foil (100% coverage) Black, FR-LSZH Technical data: Working temperature: Technical comments: -40 o C to +85 o C Frequency range: 1-250 MHz Impedans: 100 Ω Transfer impedance: grade 1 Coupling attenuation: type 1 DC-modstand: 90 Ω/km Max. resistance unbalance: 2% Capacitance unbalance: 1.2 pf/m max. Velocity of propagation: 78% Propagation delay skew: max. 25 ns/100 m Dielectric strength: 700 V/minut Dielectric strength to shield: 700 V/minut Insulation resistance (min.): 5 GΩ x km Tensile strength: max. 130 N/mm 2 Approvals: IEC 60092-359, IEC 60092-350, IEC 61156-6, IEC 61156, IEEE 802.3at (PoE+), ISO/IEC 11801, RoHS-2 2011/65/EU, IEC 60332-1, IEC 60332-3-22, IEC 60332-3, IEC 60754-1/2, IEC 61034-1/2, UL 1581 VW-1 7

Ship cables - halogen free 4x2xAWG 24/1 CAT6 S/FTP LSZH-SHF1 - Black Properties and installation: Flame retardant acc. to IEC 60332-1 Fire retardant acc. to IEC 60332-3-22 (CAT-A) Fire retardant acc. to IEC 60332-3 Low emission of corrosive gases acc. to IEC 60754 Low smoke emission during re acc. to 61034 Max. working temp. +85 C Min. working temperature -40 C Halogen free UV-resistant For use on ships For industrial use Environmentally friendly For use on oil rigs For use in homes For use in wind turbines Electromagnetical ly protected Suited for public places Meter marked For use in cable trays Water resistant Withstands moisture Withstands freezing Can lay in tubes Outdoor decommissioning For permanent outdoor installation Oil resistant 8

Ship cables - halogen free 4x2xAWG 24/1 CAT6 S/FTP LSZH-SHF1 - Black SKU EAN Dimension Current Value Winding Diameter Weight (mm²) (A) (mm)* (kg/km)* 100250153 5704403125685 4x2xAWG24 - D./Cut 7,2 58 * The values can have small deviations 9

Ship cables - reproof TOXFREE XZ1-K (AS+) IEC 60331-0,6/1 kv Application: XZ1-K (AS+) IEC 60331 is suited for xed installations on ships and o shore units in all locations. The cable material is halogen free, has low fumes emission, re retardant and re resistant. The cable are especially suitable for the installation in ships in power, lighting and control circuits. Construction: Conductor: Electrolytic annealed Cu, class 5 Insulation: Mica tape + halogen free XLPE Conductor color: 1 conductor: transparent 2 conductors: blue, brown 3 conductors: brown, black, grey 4 conductors: brown, black, grey, blue 5 conductors: with white numbers Filling sheath: If needed, the ller is thermoplastic polyole n of natural colour Outer sheath: Halogenfree thermoplastic polyole n type SHF1, orange Technical data: Working temperature: -40 C to +90 C Rated voltage: 0.6/1 kv Bend radius: < or equal with 25 mm: 4 x cable diameter > or equal with 25 mm: 6 x cable diameter Technical comments: Short circuit temp.: max 250 C / 5 sec. Current value A is meassured at 45 C CPR-klassi cering: Rekvirer DoP på dop@scankab.dk Approvals: EN 50575, IEC 60092-353, IEC 60332-1-2, IEC 60332-3-22, IEC 60331-21, IEC 60754-1, IEC 60754-2, IEC 61034-2, IEC 60092-351, CE, RoHS, Bureau Veritas, DNV, Lloyd's Register Properties and installation: For use in cable trays Bending radius 4 x cable diameter Bending radius 6 x cable diameter Flame retardant acc. to IEC 60332-1 Fire retardant acc. to IEC 60332-3 Flexible Operation secured acc. to IEC 60331 Halogen free Can lay in tubes Low emission of corrosive gases acc. to IEC 60754 Low smoke emission during re acc. to 61034 Max. working temp. +90 C Max. short circuit temp. +250 C Environmentally friendly Min. working temperature -40 C Resistance towards oil and chemicals Impact resistance: medium For use on ships Outdoor decommissioning Water resistant Suited for public places Suited for wall attachment 10

Ship cables - fireproof TOXFREE XZ1-K (AS+) IEC 60331-0,6/1 kv SKU EAN CPR Dimension (mm²) Current Value (A) Winding Diameter (mm)* Weight (kg/km)* 697001002 - C ca -s1,d1,a1 1x2,5 25 D./Cut 5,9 51 697001004 - C ca -s1,d1,a1 1x4 35 D./Cut 6,4 68 697001006 - C ca -s1,d1,a1 1x6 46 D./Cut 7,0 89 697001010 - C ca -s1,d1,a1 1x10 64 D./Cut 7,9 133 697001025 - C ca -s1,d1,a1 1x25 117 D./Cut 10,9 290 697001035 - C ca -s1,d1,a1 1x35 147 D./Cut 12,2 393 697001050 - C ca -s1,d1,a1 1x50 180 D./Cut 13,9 540 697001070 - C ca -s1,d1,a1 1x70 233 D./Cut 15,8 741 697001095 - C ca -s1,d1,a1 1x95 285 D./Cut 17,9 969 697001120 - C ca -s1,d1,a1 1x120 333 D./Cut 19,5 1212 697001150 - C ca -s1,d1,a1 1x150 386 D./Cut 21,8 1504 697001185 - C ca -s1,d1,a1 1x185 444 D./Cut 24,4 1828 697001240 - C ca -s1,d1,a1 1x240 528 D./Cut 27,4 2379 697001300 - C ca -s1,d1,a1 1x300 612 D./Cut 30,1 2981 697002001 - C ca -s1,d1,a1 2x1,5 23 D./Cut 9,2 121 697002002 - C ca -s1,d1,a1 2x2,5 31 D./Cut 10,1 154 697002004 - C ca -s1,d1,a1 2x4 43 D./Cut 11,4 209 697002006 - C ca -s1,d1,a1 2x6 55 D./Cut 12,4 266 697002010 - C ca -s1,d1,a1 2x10 75 D./Cut 14,5 395 697002016 - C ca -s1,d1,a1 2x16 100 D./Cut 16,1 542 697003001 - C ca -s1,d1,a1 3x1,5 23 D./Cut 10,0 140 697003001G - C ca -s1,d1,a1 3G1,5 23 D./Cut 10,0 140 697003002 - C ca -s1,d1,a1 3x2,5 31 D./Cut 11,0 186 697003004 - C ca -s1,d1,a1 3x4 43 D./Cut 12,2 247 697003006 - C ca -s1,d1,a1 3x6 55 D./Cut 13,3 321 697003010 - C ca -s1,d1,a1 3x10 75 D./Cut 15,7 489 697003016 - C ca -s1,d1,a1 3x16 87 D./Cut 17,9 701 697003025 - C ca -s1,d1,a1 3x25 110 D./Cut 22,3 1097 697003035 - C ca -s1,d1,a1 3x35 137 D./Cut 25,3 1470 697003050 - C ca -s1,d1,a1 3x50 167 D./Cut 28,9 2013 697003070 - C ca -s1,d1,a1 3x70 214 D./Cut 31,6 2677 697003095 - C ca -s1,d1,a1 3x95 259 D./Cut 37,7 3575 697003120 - C ca -s1,d1,a1 3x120 301 D./Cut 41,5 4480 697003150 - C ca -s1,d1,a1 3x150 347 D./Cut 46,4 5566 697003185 - C ca -s1,d1,a1 3x185 397 D./Cut 52,0 6806 697003240 - C ca -s1,d1,a1 3x240 468 D./Cut 58,4 8813 697004001 - C ca -s1,d1,a1 4x1,5 20 D./Cut 11,1 170 697004001G - C ca -s1,d1,a1 4G1,5 20 D./Cut 11,1 170 697004002 - C ca -s1,d1,a1 4x2,5 28 D./Cut 12,0 221 697004002G - C ca -s1,d1,a1 4G2,5 28 D./Cut 12,0 221 697004004 - C ca -s1,d1,a1 4x4 37 D./Cut 13,3 298 697004006 - C ca -s1,d1,a1 4x6 47 D./Cut 14,9 400 697004010 - C ca -s1,d1,a1 4x10 65 D./Cut 17,4 609 697004016 - C ca -s1,d1,a1 4x16 87 D./Cut 20,1 883 697004025 - C ca -s1,d1,a1 4x25 110 D./Cut 25,1 1379 697004035 - C ca -s1,d1,a1 4x35 137 D./Cut 27,3 1820 697004050 - C ca -s1,d1,a1 4x50 167 D./Cut 32,7 2558 697004070 - C ca -s1,d1,a1 4x70 214 D./Cut 37,0 3467 11

Ship cables - fireproof TOXFREE XZ1-K (AS+) IEC 60331-0,6/1 kv SKU EAN CPR Dimension (mm²) Current Value (A) Winding Diameter (mm)* Weight (kg/km)* 697004095 - C ca -s1,d1,a1 4x95 259 D./Cut 42,0 4524 697004120 - C ca -s1,d1,a1 4x120 301 D./Cut 46,2 5675 697004150 - C ca -s1,d1,a1 4x150 347 D./Cut 51,6 7083 697004185 - C ca -s1,d1,a1 4x185 397 D./Cut 57,9 8654 697004240 - C ca -s1,d1,a1 4x240 468 D./Cut 65,1 11243 697005001 - C ca -s1,d1,a1 5x1,5 20 D./Cut 12,0 199 697005001G - C ca -s1,d1,a1 5G1,5 20 D./Cut 12,0 199 697005002 - C ca -s1,d1,a1 5x2,5 28 D./Cut 13,2 264 697005002G - C ca -s1,d1,a1 5G2,5 28 D./Cut 13,2 264 697005004 - C ca -s1,d1,a1 5x4 37 D./Cut 14,9 364 697005006 - C ca -s1,d1,a1 5x6 47 D./Cut 16,6 490 697005010 - C ca -s1,d1,a1 5x10 65 D./Cut 19,3 747 697005016 - C ca -s1,d1,a1 5x16 87 D./Cut 22,4 1088 697005025 - C ca -s1,d1,a1 5x25 110 D./Cut 27,5 1683 697005035 - C ca -s1,d1,a1 5x35 137 D./Cut 30,7 2250 697005050 - C ca -s1,d1,a1 5x50 167 D./Cut 36,1 3137 697007001 - C ca -s1,d1,a1 7x1,5 11 D./Cut 12,9 240 * The values can have small deviations 12

SCANKAB CABLES A/S DANMARK MALERVÆNGET 3 DK-5560 AARUP DANMARK TLF.: +45 7020 3455 WWW.SCANKAB.DK SCANKAB CABLES AB SVERIGE BRISVÄGEN 3 SE-263 75 NYHAMNSLÄGE SVERIGE TLF.: +46 730-344 606 WWW.SCANKAB.SE SCANKAB CABLES AS NORGE ORSTADVEGEN 130 NO-4353 KLEPP STASJON NORGE TLF.: +47 516 37 020 WWW.SCANKAB.NO