Sentry LIQUID LEVEL ALARM MODEL 100 OPERATING MANUAL.

Similar documents
Sentry LIQUID LEVEL CONTROLLER MODEL 120 OPERATING MANUAL.

Sentry LIQUID LEVEL GAUGE MODEL 200 or 200C OWNER MANUAL REV 1.7 SEPT08 PAGE 1 OF 12

Model Gas Alarm Panel APPLICABILITY & EFFECTIVITY. This manual provides instructions for the following Sierra Monitor products:

Ion Genesis II Pump Controller Digital Level Control with Pump Alternation and High Water Alarm

Ion Endeavor Pump Controller Digital Level Control with Pump Alternation and High Water Alarm

LMA LINE MONITOR ALERT USER S MANUAL

ion Genesis Pump Controller

STATUS ALARM HISTORY ALARM RESET

MaxLite LED Vapor Tight Linear Fixture

STATUS ALARM ALARM HISTORY POWER HISTORY RESET

INSTALLATION INSTRUCTIONS

Expanded Backup Control Installation & Operator s Instruction Manual

2-Port alarmcharge Hub - Manual

SONANCE GARDEN SERIES SGS SYSTEM INSTRUCTION MANUAL

Three Phase Simplex. Installation (937) Installation Instructions and Operation/Troubleshooting Manual. Installation of Floats.

Instruction Manual Model L2 RF Switch

Installation Manual. Expansion Module 0100 Version 1.0 EXP HBX Control Systems Inc.

Silicone Rubber Heating Tape with Adjustable Thermostat Control (HSTAT Series) Instruction Manual

MODEL RLY-DIM-D INSTALLATION INSTRUCTIONS

RAM3 Remote Alarm Module

Controllers. Instruction Manual WARNING

Instruction Manual WARNING

LV-5 Direct Contact Low Voltage Detector and LV-5/K01 Kit including LV-PT Tester, Holster and Available Accessories

(HSTAT Series) Instruction Manual

STATUS ALARM ALARM HISTORY POWER HISTORY RESET

ELECTRIC FIREPLACE OWNER S MANUAL

Air Pump Up to 800 gallons

Protocol Station Remote Alarm

HotPoly Tote Tank / IBC Heaters (TTH Series)

Operating Instructions Model 4400/VC-115V Portable Powder Filler (115VAC. Model)

RATIO:GUARD Model E-1S EC Monitor

WATCHMAN Model LBW-WATCHMAN Ammonia Leak Detector

ELP21LU3-LF-HLOL THREE CHANNEL

Model 4001 Series Single Channel Controller

LED LAMP: To turn on the LED Lamp, press the LIGHT BUTTON located on the front. Press again to turn off.

MaxLite LED MICRO-T PANEL

MaxLite LED VAPOR TIGHT LINEAR FIXTURES

ELECTRIC FIREPLACE HEATER WITH SINGLE GLASS DOOR

Non-Programmable Digital Thermostat

INSTALLATION & OPERATION MANUAL

OWNERS MANUAL For IN ROOM BREWING SYSTEM MODEL REFILLABLE CAPSULES K901. Includes: Installation Use & Care Servicing Instructions

Surge Protective Devices Installation, Operation and Maintenance Manual. LowProfile Series: 080 and 120

Models LBW-420-LEL (24 VDC powered) Ammonia Leak Detector

MaxLite LED Round Pendant Highbay Series

TTSIM-1A. TraceTek Sensor Interface Module with Relay. Installation/Operation Instructions. Installation Items (not supplied) Tools Required.

Owner & Operator s Manual. Table of Contents

ST. KITTS CEILING FAN

Installation Manual. THM-0100 Setpoint Thermostat Version THM HBX Control Systems Inc.

Installation and Owner Man u al

BLT-999W-2 Item # 60757

OPERATION, SERVICE & PARTS MANUAL

CT2 Retro Box Installation Instruction Manual

ASG EZ-9000GR Tape Dispenser User Manual ASG #66136

Master Prep Frozen Treat & Drink Maker

Multiple Boilers Electro TS Series Application EB-C-STG5

MaxLite 4, 6, 8 & 9 LED Architectural & Commercial Downlights

Master Prep Chopper OWNER S GUIDE QB600W

Consumer Products Catalog

Single Station Remote Alarm

OCH-SS series Direct Wired Units Indoor * and Outdoor Comfort Heaters

Figure 1. These Installation Instructions -1- K4866 4/00 OmniProx Reader Model Series OP-10/20/30/40

3800 North Mill Road Vineland, NJ USA Tel: Fax: Web: Rev. A

MAN AUTO IMPORTANT INSTRUCTIONS PLEASE READ THIS MANUAL BEFORE INSTALLING AND USING APPLIANCE

Spa Control System OWNER S MANUAL

SAFETY INFORMATION AND WARNINGS

AFA 500 FUME HOOD ALARMS

Bench Top Ionizer Installation, Operation and Maintenance

IN-GROUND SUBWOOFER INSTRUCTION MANUAL LS12T SUB LS15T SUB

Wrap-Around TOTE Tank / IBC Heaters (TOTE and TOT Series)

3 Scotch Mini-Weld Adhesive System User s Manual

SPILLSTOP ULTRA Alarm Controller with Hose Protection Overfill Prevention System

Interrupted Ignition Series Oil Primary Control

36 IN. ELECTIC FIREPLACE FMI MODEL # LEF36 Mounting Base Feet and Wall Mounting Bracket Included

RAM-208. Remote Multiplex Annunciator Panel. Wiring & Installation Installation Manual COMMON TROUBLE A.C. ON SIGNAL SILENCED BUZZER SILENCE

OWNERS MANUAL MODEL EXTERMINATOR VS900 C/R BLACK VAPOR CLEANING SYSTEM SAFETY INSTRUCTIONS OPERATIONS CARE AND MAINTENANCE TROUBLESHOOTING WARRANTY

LiqTec, V GRUNDFOS INSTRUCTIONS

OWNER'S MANUAL T0140. Contents Page #

SYSTEM CONTROL KIT Model: CK-41P

INSTALLATION AND OPERATING INSTRUCTIONS FOR THE VEHICLE-MOUNTED RADIATION DETECTION SYSTEM

MODEL 8143 SIGNAL SELECTOR INSTALLATION AND OPERATION MANUAL

Supplement to The PDRP-1001/PDRP-1001A/PDRP-1001E Deluge Preaction Control Panel Manual

ARMITAGE CEILING FAN ITEM # MODEL #CC52WW5L. Español p. 17 ATTACH YOUR RECEIPT HERE. Purchase Date

FW-RA-LED Remote Multiplex Annunciator Panels

SEALING FIBER SEALING COMPOUND

Environmental Monitoring SmartSlot Card

TILGHMAN CEILING FAN. LISTED For Damp Location E ITEM # MODEL #WCK52LMW5N WCK52NWZ5N. Español p. 20 ATTACH YOUR RECEIPT HERE

OWNER S MANUAL PLEASE READ AND SAVE THESE INSTRUCTIONS WHOLE ROOM RADIATOR HEATER. Model: HO-0221 THERMOSTAT

NT DUAL CHANNEL DISPLAY. User Guide

ELECTRIC STOVE MODEL CGESS SAFETY INFORMATION AND OPERATION MANUAL

TMC. Installation and Operation Manual TMC. Temperature and Pressure Monitoring for Heating and Cooling Applications. Temperature Monitoring Control

AMC-RAM-4. Refrigerant Alarm Module USER MANUAL. Please read the installation and operating instructions completely and carefully before starting.

MAINTENANCE & TROUBLESHOOTING GUIDE LEAK ALARM CHANNEL DRY OIL WATER AUX ALARM HIGH LOW CRITICAL WATER TANK LEVEL ALARM MODEL LDE-740 ADVANCE PAPER

Single Phase Simplex SXL21=3, SXL24=3, SXH21=3, and SXH24=3

installation instructions Fan Tray System FTA-3/FTA-6

Mold Alert... Operation Manual P0270

PSW112 Owners Manual. Platinum Series Subwoofer. Models. PSW112 Powered Subwoofer

expandable led Installation & Maintenance Guide Product Description Light 48 IN 21.6W 10K/460nm Expandable Light 36 IN 15W 10K/460nm Expandable

IMPORTANT SAFETY INFORMATION:

CD6102 / CD6102 OC / CD6102-2

Model 20201/20201-A/20201-B Wind Sensor Heater. User's Manual. All Weather Inc National Drive Sacramento, CA USA

Transcription:

Sentry LIQUID LEVEL ALARM MODEL 100 OPERATING MANUAL www.aquaticsentry.com

TABLE OF CONTENTS 1. SAFETY PRECAUTIONS... 3 2. APPLICATION... 3 2.1 HIGH Liquid Level Alarm 2.2 LOW Liquid Level Alarm 3. INSTALLATION... 4 3.1 Mount Indoor Alarm Display 3.1.1. Setting HIGH or LOW Level Function 3.2 Suspend the Probe 3.3 Test the Alarm 3.3.1 HIGH Alarm 3.3.2. LOW Alarm 3.4 Optional Relay Output 4. OPERATION and TROUBLESHOOTING... 9 4.1 State Table and Troubleshooting 4.2 Manual Test 4.3 Probe Response Time 5. SPECIFICATIONS... 11 5.1 Indoor Alarm Display 5.2 Probe 6. WARRANTY... 12 Printed in Canada Rev Oct 2015 Page 2

1. SAFETY PRECAUTIONS The potential for electrical shock exists whenever water is present near conductive electrical equipment. Check for sources of electricity from other nearby devices before working on this equipment. There is no possibility of serious shock from the energy levels used by this alarm. The low voltage DC and transformer isolation provide safety when handling or opening the enclosures or the probe. Best practice, however, is to disconnect power when working on this equipment. 2. APPLICATION The Sentry liquid level alarm continuously monitors a water level, rising (high level) or falling (low level), that may cause an alarm condition. Application examples are pump chambers, cisterns, holding tanks, sumps, floor drains, irrigation channels or truck tanks. The alarm also performs self-diagnostics, continuously testing that all components are operating correctly. The indoor alarm display will flash an LED and sound audible alarm. Audio can be muted with the pushbutton. When the alarm condition is corrected the audio will reset. Green indicates power on and monitoring Red flashing and audio pulsing indicates an alarm condition Yellow indicates an error in the probe circuit See the State Table in Section 4.1 for the complete detail of the conditions which may be displayed and the self-diagnostics. 2.1 HIGH Liquid Level Alarm HIGH LEVEL alarm condition will occur when the liquid level rises to partially cover the pins on the bottom of the probe. An example of rising water causing an alarm condition is a septic tank. 2.2 LOW Liquid Level Alarm LOW LEVEL alarm condition will occur when the liquid level falls close to the middle of the pins of the probe. An example of falling water level causing an alarm condition is a cistern that requires filling. Page 3

3. INSTALLATION 3.1 Mount Indoor Alarm Display Mount the Sentry indoor alarm display at a convenient viewing location. Select an eye level location that is frequented, near a 120VAC receptacle. Power to the receptacle should be supplied from a circuit separate from any pump that is being monitored by this alarm. Install the supplied screws, 3 apart vertically and projecting ¼ from the wall, to mount the display. Install the AC adapter and plug into the alarm display. The LED will be flashing red and yellow, indicating that the probe is disconnected. See the State Table in Section 4.1 for the complete detail of the conditions which may be displayed and the self-diagnostics. The supplied labels may be used to identify the indoor alarm display s function, ie HIGH LEVEL in the SUMP. 3.1.1. Setting HIGH or LOW Level Function The jumper position inside the indoor alarm display determines the HIGH LEVEL or LOW LEVEL function to suit your application. See FIG 1 next page. Using needle nosed pliers, install the jumper, shorting the two terminals for a HIGH LEVEL function. For a LOW LEVEL function the jumper is installed on one terminal. Page 4

FIG 1 Indoor Display Rear Interior Page 5

FIG 2 Probe with Suspension Clip 3.2 Suspend the Probe Suspend the probe at the depth the alarm is required. Tape the cable to a riser with electrical tape or use the supplied clip to grip the probe cord. See FIG 2 above. Use wire that will not corrode, such as insulated building wire, bent into an S hook, to suspend the probe from a projection in or off the rim of the neck of the tank. The probes alarm point occurs when the pins are partially covered by water. Once the probe has been installed at the correct location plug it into the indoor alarm display. Page 6

3.3 Test the Alarm 3.3.1 HIGH Alarm For a HIGH ALARM the LED will be green and on steady with the probe out of the liquid. When the probe is lowered into the liquid, the LED will turn flashing red and the audible alarm will pulse. Silence the audible alarm. Raise the probe out of the liquid to stop the red LED flashing and to reset the audible alarm. Repeat this sequence to prove operation. For any other conditions see the State Table in section 4.1. 3.3.2. LOW Alarm For a LOW ALARM the LED should be green and on steady with the probe in the liquid. When the probe is raised above the water, the LED will turn flashing red and the audible alarm will pulse. Silence the audible alarm. When the probe is lowered into the liquid the LED will turn steady green indicating alarm is monitoring. Repeat this sequence to prove the operation. For any other conditions see the State Table in section 4.1. Page 7

3.4 Optional Relay Output The relay output may be used to switch an external circuit to operate remote alarms, security systems, autodialers or other control applications. The spring clamp terminal block on the indoor display accepts 26-14 gauge solid or stranded wire. See Fig 3 below. Depress the orange lever and insert the stripped wire into the terminal block. FIG 3 Relay Option Page 8

4. OPERATION and TROUBLESHOOTING 4.1 State Table and Troubleshooting State Table and Troubleshooting for the Indoor Alarm Display LED AUDIO HIGH LEVEL (i.e. Septic tank) LOW LEVEL (i.e. Cistern) CORRECTIVE ACTION OFF OFF No Power Check breaker Check Transformer Check plug-in into display GREEN STEADY OFF PROBE DRY PROBE WET OK RED FLASHING PULSING ALARM - PROBE WET ALARM - PROBE DRY OK RED FLASHING SILENCED ALARM - PROBE WET ALARM - PROBE DRY OK YELLOW FLASHING PULSING MANUAL TEST OK GREEN / YELLOW FLASHING CONTINUOUS PROBE ERROR Replace probe RED STEADY CONTINUOUS PROBE SHORT Check polarity of the probe conductors Check probe wire for damage; make a waterproof repair RED / YELLOW FLASHING CONTINUOUS PROBE DISCONNECTED Check probe wire for damage Connect probe wires 4.2 Manual Test A manual test function is incorporated into the indoor alarm display. Pressing down and holding the Audio button will test the software and hardware and return a yellow flashing LED and a pulsing alarm sound. 4.3 Probe Response Time The indoor alarm display will respond within 3 seconds to a change in alarm state from the probe. Page 9

FIG 4 Indoor Alarm Display Rear Label Page 10

5. SPECIFICATIONS 5.1 Indoor Alarm Display Power Supply - 120VAC, 60 Hz input, 9VDC 200 ma output, UL listed, CSA certified, indoor unit, power consumption typically.05 watts, 0.9 watts maximum during alarm condition Enclosure - flame retardant ABS High level, Low level function selectable LED - tricolor Audible alarm - solid state transducer, 85db @ 10cm Optional relay output dry contacts normally open, 2A @30 VDC, 0.4A @ 125 VAC rating 5.2 Probe Digital RF proximity probe, stainless steel, type 304 or 316, 24.4mm diameter x 100mm long, cable Suspension clip HDPE, UV resistant Cable - 18ga, 2 conductor, CSA CMG FT4, 15m (50 feet) length standard Page 11

6. WARRANTY Aquatic Sentry Controls Inc. warrants that this product is free from defects in materials and workmanship under normal use and service for a period of three years from the date of purchase by the initial owner. Aquatic Sentry shall be responsible only for actual loss or damage suffered and then only to the extent of Aquatic Sentry s invoiced price. Within the warranty period we shall repair, refurbish or replace, at our option, such products or components, which are returned to us with shipping charges prepaid, and which are determined by us to be defective. This warranty will not apply to any product or part thereof which has been subject to misuse, negligence, or accident; or misapplied; or modified; or repaired by unauthorized persons; or improperly installed. The provisions of the above warranty are our sole obligation and exclude all other remedies or warranties, expressed or implied, including warranties of merchantability and fitness for a particular purpose, whether or not purposes or specifications are described herein. We further disclaim any responsibility whatsoever to the customer, or to any person, for injury to person, damage to, or loss of property or value caused by any product, regardless of whether the defect is warrantable or whether the product has been subjected to misuse, negligence, accident; or modified or repaired by unauthorized persons; or improperly installed. Under no circumstances shall the company be liable for any incidental, consequential or special damages, loss or expenses arising from the use of this product, or in connection with the use of, or inability to use, our product for any other purpose whatsoever. Aquatic Sentry products or parts thereof assumed to be defective by the purchaser within the stipulated warranty period should be returned to the seller or local distributor for evaluation and service. If deemed necessary, the seller or distributor shall contact Aquatic Sentry Controls Inc. for a Returned Materials Authorization and then return the item for direct factory evaluation, service or replacement. No material may be returned to Aquatic Sentry Controls Inc without proper factory authorization. Page 12

NOTES Page 13

NOTES Page 14

NOTES Page 15

www.aquaticsentry.com