Ex SOLENOID / ALARM DRIVER. PRepower 5203B. Table of contents. Applications Safety instructions Technical characteristics...

Similar documents
I.S. Interfaces. for the Process Industry. display. i.s. interface. isolation. temperature. universal

SBEx-4 BISTATE SEPARATOR 1, 2, 3 or 4 channels in rail housing (TS35, 22,5mm width)

I.S. Interfaces. for the Process Industry. display. i.s. interface. isolation. temperature. universal

Operating Instructions. For. Alarm Control Module. Model SSR 500

RE-PR3-E-27 3-Phase Panel Mount 27kW

WIO200 Water In Oil measuring instrument

WIO200 Water in oil sensor

AO Annunciator Module

OilSET Installation and Operating Instructions. Oil Separator Alarm Device with SET/DM3AL sensor

Instructions for the fan motor control system with integrated wiring terminals SILVER C

L1L2L3. 99 Washington Street Melrose, MA Phone Toll Free Visit us at

Industrial Solid State Contactor TE10S. Static switching of resistive loads and shortwave infrared heating tubes up to 20 kw

LC2200 Level Controller Installation and Maintenance Instructions

OilSET Installation and Operating Instructions. Oil Separator Alarm Device

Thermo-Sealer. Manual Heat Sealer. User Manual

Process Alarm Module RTA 421

Model 144H. Product Data Sheet , Rev DB February Content

Model 144H. Product Data Sheet , Rev DB February Content

DSF xx10.xx xhv Ex-Atex Hall Effect Single Channel Speed Sensor

Instructions for the fan motor control system, SILVER C

USER GUIDE. DRENA 2 - User Manual ELECTRICAL PANEL FOR 2 MOTORS - WASTE WATER -

Manual Power relay SR853

Technical Data. General specifications Switching element function Rated operating distance s n 4 mm

PROTECT SRB 200EXi-1A

Technical Data. Dimensions

Technical Data. Dimensions

HYTEK ATEX APPROVED TANK ALARM

Snifter ATEX22 VERSION. User Manual. Distributor

Series 155. Mass Flow Computers TECHNICAL SPECIFICATIONS

Technical Data. General specifications Switching element function Rated operating distance s n 5 mm

EN - english. Instructions for installation and operation. Mobile humidity meter DP 207

INSTALLATION GUIDE. AXIS A1001 Network Door Controller

Manual Isolating Barrier D461R1 (Revision 01)

Rectifier RC-series. Manual RC-series English MA doc. Manual Wall and 19 English

Wind Alarm Instrument

Lodam Compressor Protection Module. Technical manual. Version 3.0 SE-G1

Operating Manual MS220DA

OilSET-1000 (12 VDC)

Advanced Diagnostic Gateway with Ethernet and FF-H1 Interface and I/O. Assembly

SET Installation and Operating Instructions. Level switch for one sensor

OPTIBAR DP 7060 Supplementary Instructions

Intrinsically Safe Pressure Transmitters for installation in hazardous locations Models IS-20-S, IS-21-S, IS-20-F, IS-21-F WIKA Datasheet IS-20

Emergency power automatics MS-2. High resistance to shock, vibrations and transients. All output are 2A relay contacts

PEPPERL+FUCHS GmbH

Technical Data. Dimensions

JBE LED2000 INDUSTRIAL SOLUTIONS FOR LED & INCANDESCENT MAINS LIGHTING FLICKER FREE TRAILING EDGE DIMMER

SET-2000 Hi Level/Oil

Operating instructions Safety-monitoring module SRB 302X3. 1 About this document

RTK Instruments Limited St James Business Park, Knaresborough, North Yorkshire, England. HG5 8PJ

GETTING STARTED GUIDE NI RTD, 0 Ω to 400 Ω, 24 Bit, 400 S/s Aggregate, PT100

INTRODUCTION / TABLE OF CONTENTS

WIO 200B and WIOI200B Water in oil sensor

Inductive slot sensor

Pressure sensors. Ex ia I / IIC T6 acc. to ATEX. Features. Description. Measuring ranges. Applications

Technical Data. General specifications Switching element function Rated operating distance s n 5 mm

Assembly. Host Sub-D Alarm

L+T GASETECHNIK. Klöpper-Waldmann GmbH & Co. K G. Alarm unit LSG4

4) Intrinsic Safety Certification

4 Ó â. Contactor RTA421. Contactor with loop power supply for monitoring currentorvoltagesignals. Technical information TI074R/09/en

Advance Optima Continuous Gas Analyzers AO2060-Caldos15, -Caldos17, -Magnos106, -Uras14 Category 2G Analyzer Modules

Gas cylinder scale Model GCS-1

LZR -H110. LASER SCANNER FOR BARRIERS & GATES with max. detection range of 5.0 m x 6.5 m (16.5 ft x21 ft) User s Guide

Operating instructions Safety-monitoring module SRB 302X3. 1. About this document. Content

DSF xx15.xx xhv Ex-Atex Ex-Atex Certified Two wire Hall Effect Speed Sensor

Assembly. Connection overflow sensor. Connection fat level sensor OFF ON

Translation of the assembly instructions with operating instructions and technical appendix

INSTALLATION AND OPERATING MANUAL

S304 and S305 Dust Emission Monitors. User Manual. Distributor

Certificate of Compliance

User manual. Explosion-safe window air conditioning system Type series AR-054. II 3 G Ex ic nac h IIC T3 Gc

Operating Instructions for Limit switch Model: NBK-R NBK-RM NBK-RT NBK-RA

ISOMETER IRDH275BM-7 with coupling device AGH675-7 and AGH675-7MV15

HYTEK ATEX APPROVED BUND ALARM

GETTING STARTED GUIDE NI Channel, 0 ma to 20 ma, 16-Bit Analog Output Module. This document explains how to connect to the NI 9265.

Archive. LC2200 Level Controller. 1. Safety information. 2. General product information. 3. Installation. 4. Setting up the controller

SMART EVO 2 - User Manual ELECTRICAL PANEL FOR 2 MOTORS

Certificate of Compliance

Technical Data. General specifications Switching element function Rated operating distance s n 8 mm

OMC Ex interface unit. Manual. Version 1.2 August Author: Observator Instruments

ELECTROPROJECT GTV-A POWER SUPPLY FOR DOOR MAGNETS

INSTRUCTION MANUAL (ATEX)

Regulated Ex-Heater HEX with internal controller, HEX with external controller II 3 G II 3 D

FlowJam S Ex. Bulk Flow Detection. Operating Instructions. SWR engineering Messtechnik GmbH

Approvals, Safety Instructions, and Statutory Information

INSTRUCTION MANUAL T30 1MN0107 REV. 0. operates with ISO9001 certified quality system

SET-2000 Oil/Sludge. Alarm Device for Oil Separators. Installation and Operating Instructions

DB5 Intrinsically Safe Sounder Type DB-5

GETTING STARTED GUIDE NI DI, 30 V, Sourcing, 7 μs

Dry Bath Heating Systems

THERMAL BUILDING SOLUTIONS EN-TraceTekTTSIM1A-IM-H /16

APPLICATION DATA SHEET

RFM Series RFM-ISR Barrier. Installation Manual

Magnetic-Inductive Flow Velocity Sensor PIT. Installation and Operating Instructions

GETTING STARTED GUIDE NI TC, ±78 mv, 24 Bit, 75 S/s Aggregate

INSTRUCTION MANUAL IS-mB1 Minialite Intrinsically Safe Round LED Beacon

FIRE ALARM CONTROL EQUIPMENT. Addendum October 2006 Instructions for new style EN54-4 Power supply unit module

Manual Isolating Barrier D461 (Revision 05)

Electronic Temperature Controller 70304,

LZR -I30. max. detection range of 30 ft x 30 ft LASER SCANNERS FOR INDUSTRIAL DOORS LZR-I Page 1 of 12

Power Supply Display Module PSDM. Installation and Operation Manual

Transcription:

14 Ex SOLENOID / ALARM DRIVER PRepower 5203B Table of contents Warnings... 16 Safety instructions... 17 Declaration of Conformity... 19 How to dismantle SYSTEM 5000... 20 Application... 21 Technical characteristics... 21 Mounting / installation... 21 Applications... 22 Order... 23 Electrical specifications... 23 Dipswitch programming... 24 Ex data... 25 Connections... 26 Block diagram... 27 15

GENERAL HAZARD OUS VOLTAGE INSTAL- LATION 16 WARNING! This module is designed for connection to hazardous electric voltages. Ignoring this warning can result in severe personal injury or mechanical damage. To avoid the risk of electric shock and fire, the safety instructions of this manual must be observed and the guidelines followed. The specifications must not be exceeded, and the module must only be applied as described in the following. Prior to the commissioning of the module, this manual must be examined carefully. Only qualified personnel (technicians) should install this module. If the equipment is used in a manner not specified by the manufacturer, the protection provided by the equipment may be impaired. WARNING! Until the module is fixed, do not connect hazardous voltages to the module. The following operations should only be carried out on a disconnected module and under ESD safe conditions: Dismantlement of the module for setting of dipswitches and jumpers. General mounting, connection and disconnection of wires. Troubleshooting the module. Repair of the module and replacement of circuit breakers must be done by PR electronics A/S only. WARNING! To keep the safety distances, modules 5111 and 5223 must neither be connected to hazardous nor non-hazardous voltages on the same module s relay contacts. SYSTEM 5000 must be mounted on DIN rail according to DIN 46277. The communication connector of SYSTEM 5000 is connected to the input terminals on which dangerous voltages can occur, and it must only be connected to the programming unit 5905 by way of the enclosed cable. SYMBOL IDENTIFICATION Triangle with an exclamation mark: Warning / demand. Potentially lethal situations. The CE mark proves the compliance of the module with the essential requirements of the directives. The double insulation symbol shows that the module is protected by double or reinforced insulation. Ex modules have been approved acc. to the ATEX directive for use in connection with installations in explosive areas. SAFETY INSTRUCTIONS DEFINITIONS: Hazardous voltages have been defined as the ranges: 75 to 1500 Volt DC, and 50 to 1000 Volt AC. Technicians are qualified persons educated or trained to mount, operate, and also troubleshoot technically correct and in accordance with safety regulations. Operators, being familiar with the contents of this manual, adjust and operate the knobs or potentiometers during normal operation. RECEIPT AND UNPACKING: Unpack the module without damaging it and make sure that the manual always follows the module and is always available. The packing should always follow the module until this has been permanently mounted. Check at the receipt of the module whether the type corresponds to the one ordered. ENVIRONMENT: Avoid direct sun light, dust, high temperatures, mechanical vibrations and shock, as well as rain and heavy moisture. If necessary, heating in excess of the stated limits for ambient temperatures should be avoided by way of ventilation. All modules fall under Installation Category II, Pollution Degree 1, and Insulation Class II. 17

MOUNTING: Only technicians who are familiar with the technical terms, warnings, and instructions in the manual and who are able to follow these should connect the module. Should there be any doubt as to the correct handling of the module, please contact your local distributor or, alternatively, PR electronics A/S, Lerbakken 10, DK-8410 Rønde, Denmark, tel: +45 86 37 26 77. Mounting and connection of the module should comply with national legislation for mounting of electric materials, i.a. wire cross section, protective fuse, and location. Descriptions of input / output and supply connections are shown in the block diagram and side label. The following apply to fixed hazardous voltages-connected modules: The max. size of the protective fuse is 10 A and, together with a power switch, it should be easily accessible and close to the module. The power switch should be marked with a label telling it will switch off the voltage to the module. CALIBRATION AND ADJUSTMENT: During calibration and adjustment, the measuring and connection of external voltages must be carried out according to the specifications of this manual. The technician must use tools and instruments that are safe to use. NORMAL OPERATION: Operators are only allowed to adjust and operate modules that are safely fixed in panels, etc., thus avoiding the danger of personal injury and damage. This means there is no electrical shock hazard, and the module is easily accessible. CLEANING: When disconnected, the module may be cleaned with a cloth moistened with distilled water or ethyl alcohol. LIABILITY: To the extent the instructions in this manual are not strictly observed, the customer cannot advance a demand against PR electronics A/S that would otherwise exist according to the concluded sales agreement. 18 DECLARATION OF CONFORMITY As manufacturer PR electronics A/S Lerbakken 10 DK-8410 Rønde hereby declares that the following product: Type: 5203B Name: Ex solenoid / alarm driver is in conformity with the following directives and standards: EMC directive 89/336/EEC and later amendments From serial no.: 990301001 ff EN 61 326 EN 50 081-1, EN 50 081-2 EN 50 082-1, EN 50 082-2 This declaration is issued in compliance with article 10, subclause 1 of the EMC directive. For specification of the acceptable EMC performance level, refer to the electrical specifications for the module. The Low Voltage directive 73/23/EEC and later amendments from serial no.: 990301001 ff EN 61 010-1 The ATEX directive 94/9/EC and later amendments From serial no.: 990301001 ff EN 50 014 and EN 50 020 Ex certificate: 99 ATEX 126257 Notified body for CENELEC/ATEX: UL International Demko A/S 0539 Rønde, 11 Aug. 2000 Peter Rasmussen Manufacturer s signature 19

HOW TO DISMANTLE SYSTEM 5000 First, remember to demount the connectors with hazardous voltages. Picture 1: By lifting the bottom lock, the module is detached from the DIN rail. Picture 2: Then, by lifting the upper lock and pulling the front plate simultaneously the PCB is removed. Switches and jumpers can now be adjusted. 20 Ex SOLENOID / ALARM DRIVER PRepower 5203B 1- or 2-channel version 3- / 5-port 3.75 kvac galvanic isolation Solenoid driver for Ex area Digitally controlled voltage supply for Ex area Universal supply by AC or DC Application: Driver with safety barrier for the control of ON / OFF solenoids mounted in hazardous area. Driver with safety barrier for the supply of LEDs and acoustic alarms mounted in hazardous area. Voltage supply with ON / OFF control of other equipment. Technical characteristics: PR5203B has a digital input per channel for the control of the Ex output voltage. Supply, inputs and outputs are floating and galvanically separated. Mounting / installation: Mounted vertically or horizontally on a DIN rail. By way of the 2-channel version up to 84 channels can be mounted per metre. 21

22 Valve LED Acoustic alarm Digital input Supply Digital input Supply Digital input Supply Electrical specifications: Specifications range: (@: -20 C to +60 C) Common specifications: Supply voltage universal... 24...230 VAC ±10% 50...60 Hz 24...250 VDC ±20% Internal consumption...! 2 (2 channels) Max. consumption...! 4 W (2 channels) Fuse... 400 ma SB / 250 VAC Isolation voltage, test / operation... 3.75 kvac / 250 VAC Max. frequency... 20 Hz Calibration temperature... 20...28 C EMC immunity influence... < ±0.5% of span Extended EMC immunity: NAMUR NE 21, A criterion, burst... < ±1% of span Max. wire size... 1 x 2.5 mm Screw terminal torsion... 0.5 Nm 2 Relative humidity... < 95% RH (non-cond.) Dimensions (HxWxD)... 109 x 23.5 x 130 mm DIN rail type... DIN 46277 23

Tightness (enclosure / terminals)... IP50 / IP20 Weight... 230 g Inputs: NPN and mechanical switch: Trig level LOW..."! 4.0 VDC Trig level HIGH... #"7.0 VDC Max. external voltage... 28 VDC Input impedance... 3.48 k$ PNP: Trig level LOW..."! 4.0 Trig level HIGH... #"7.0 V Max. external voltage... 28 VDC Input impedance..."3.48 k$ Outputs: Output voltage... See Ex data table Output current... See Ex data table Output ripple... < 40 mvrms Observed authority requirements: Standard: EMC 89/336/EEC, Emission... EN 50 081-1, EN 50 081-2 Immunity... EN 50 082-2, EN 50 082-1 Emission and immunity... EN 61 326 LVD 73/23/EEC... EN 61 010-1 PELV/SELV... IEC 364-4-41 and EN 60 742 ATEX 94/9/EC... EN 50 014 and EN 50 020 Dipswitch programming: 24 25

26 27