Control System Studio - CSS - Alarm Handling

Similar documents
Best Ever Alarm System Toolkit

ArchestrA Direct Connect

Monitor Alarms and Events

Effective Alarm Management for Dynamic and Vessel Control Systems

Alarms and Events. Defining Alarm Conditions. Database-Generated Alarms

Monitor Alarms and Events

Manual# User s Manual. 200E Series. DCU 210E/208E Diesel Engine Control Unit RP 210E Remote Panel

Operation Manual Fighter ProVision Software. Version: 0.0 Revision: 1

Using ANM Mobile CHAPTER

Manual# User s Manual. 200 Series. DCU 210/208 Diesel Engine Control Unit RP 210 Remote Panel

Alarm Handler User's Guide

Running IGSS as an Operator, Part One

Halton SAFE / 7.14 user guide and installation instructions

Monitoring Operator Guide. Access Control Manager Software Version

Installation and User Instructions

Q&A Session from Alarm Management Workflow Webinar (Apr.24/2013)

SimpleComTools, LLC 1

Alarm Manager Plug-in

i-vu CCN 4.0 Owner s Guide

Avigilon System Integration Guide. for the Avigilon Control Center and Access Control Manager

Advanced Protection Logic Lynx Touch & Lyric Series

Platform Services BACnet Alarm Management

Smart Combiners Installation Guide. For Obvius A89DC-08 sensor modules

RAy SNMP. Application notes.

ixarmaxml Driver configuration

Sensaphone 400 Telemetry System Integration

Avigilon Control Center 5 System Integration Guide

Weekly Testing of Dedicated Smoke Control Dampers - Metasys System Extended Architecture

user s manual VUBMG102

1 Introduction Data transmission Compatibility IPS Analytics configuration... 3

ALARMING NEWS FROM INVENSYS PROCESS SYSTEMS, INC.

Raytec Avigilon Integration User Guide Integrating Raytec Network Illuminators with Avigilon Control Center Document Revision 2.0

Weekly Testing of Dedicated Stairwell Pressurization Fans- Metasys System Extended Architecture Code No. LIT

Milestone SMI Intrepid II Perimeter Module 1.1 User s Manual

Laptop / PC Programming Manual

PWM. Solar Charge controller with Ethernet. Solar Smart PWM 20Amp. Hardware Description : Release : 19 June 2014

I/A Series A 2 Software FoxAlert Alarm Manager

Alarms for the Cisco ISA 3000

CODAC Core System 5.4 CS-Studio Release Notes

D-Link Central Management System

Options Specification

WorkstationST* Alarm Viewer

Procidia iware AlarmWorX32. AlarmWorX32 Viewer January 2010

System Galaxy Quick Guide

Instruction manual MTL process alarm equipment. October 2016 CSM 725B rev 2 MTL RTK 725B. Configuration Software Manual

Alarm System Performance Metrics

Security System. User s Guide for the Text Command Center

Rotem One Touch. User Manual PRELIMINARY DOCUMENT. Ag/MIS/UmGB /18 Rev 1.0 P/N:

Intelligent alarm management

DATA SHEET BENEFITS CURRENT CHALLENGES SSM INFOTECH S X-FORCE AMS - THE IDEAL SOLUTION

Deltapilot S FMB70. Functional Safety Manual. Level and Pressure Measurement with Output Signal ma

Replaceable LED modules. Sleep or unattended mode. Auto-silence and auto-acknowledge

Product introduction Layers of Protection Layer 3: Safety System Instrumented & Mechanical. Layer 2: Alarms Manual action needed

Economic and Effective Alarm Management

Making the Most of Alarms

Ontech GSM 9040/50. Reference Manual English -1 -

Alarms Updated 03/26/2018

3D_ISS. Integrated Software System. User Guide Manual

ZX1e ZX2e ZX5e. Document No Issue 01 user manual

presentations the week of the final exams. Anyone who misses the appointment will receive a grade of zero.

BlackBerry AtHoc Networked Crisis Communication Siemens Indoor Fire Panel Installation and Configuration Guide Release Version 7.

725B Configuration Software Manual

Ademco Vista Alarm Panel

AxxonSoft. Operation Manual TROMBONE. Fire and Security Alarm Integration Module. Version 1.1. Moscow

Table of Contents. i-vu CCN Standard 4.2

Ovation Alarm Management System

PORTAL USER MANUAL. Mobeye WaterGuard-FS. Float sensor CM2300FS. SW version 5.n

Avigilon System Integration Guide. for the Avigilon Control Center and Access Control Manager

Configuration and Operation Manual for the Unipos

Ion Gateway Cellular Gateway and Wireless Sensors

Technical Publications. FactoryTalk Alarms and Events System Configuration Guide

1. Functions of GPS locator ETLOC-30S 3

F Technical Bulletin SC 370 SMART Modbus Interface

Managing Network Alarms and Events

SCADA ALARM MANAGEMENT. Tim Okely. GWMWater

Avigilon Control Center 5 System Integration Guide

PANIC, The ALBA Alarm System. Sergi Rubio Manrique, ALBA Synchrotron, Barcelona

Tech Data Sheet D01662GB0_Esgraf 4.1 and Configuration Server 30/2011 2/(5)

FactoryTalk Alarms and Events. System Configuration Guide

AGC 200 Advanced Gen-set Controller OPERATOR S MANUAL

Alarm module for leak detection with webserver

Bosch TCU Integration Module Administrator's Guide

Platinum Touch/Rotem One Touch

2017/11/16 P a g e 1

Avigilon Control Center System Integration Guide

PotterNet Fire & Facility Supervising Station

Oracle Communications Performance Intelligence Center

Functional Description AIS01 - Analog Input Signal Version 5.2-0

FlameGard 5 UV/IR HART

TOUCH PANEL INSTRUCTION MANUAL

ZERIO PLUS EDA-Z5008, Z5020 & Z5100

Meridian wiredhart. HART Field Device Specification Goldmine Rd. Monroe, NC USA

HERCULES 6 GRAPHICS SYSTEM

Avigilon Control Center System Integration Guide

Managing Network Alarms and Events

Setting up and Managing Alarms in McAfee ESM 10.x

User s Manual. System Information... 3 Using the Touchpad Buttons... 3 General Operation... 4 Using Systems with Keyswitches... 4

Security System. User Guide for the LED Command Center

Simplex Panel Interface Guide

Planning Instructions MEW00443 Revision -

Transcription:

Control System Studio - CSS - Alarm Handling Kay Kasemir, Ph.D. ORNL/SNS kasemirk@ornl.gov June 2011 at KEK Managed by UT-Battelle

Previous Attempts at SNS ALH; manual summary displays; generated soft-iocs + displays Issues GUI Static Layouts N clicks to see active alarms Configuration.. was bad Always too many alarms Changes required contacting one of the 2 experts, wait ~days, restart CA gateway, hope that nothing else broke Information Operator guidance? Related displays? Most frequent alarm? Timeline of alarm? 2 Managed by UT-Battelle

Now: Best Ever Alarm System Tool Yes, alarms are always a little scary 3 Managed by UT-Battelle

Alarm System Components Cool UI Configuration Alarm Server Control System 1. What you see 2. Technical details 3. How to use it 4 Managed by UT-Battelle B. Hollifield, E. Habibi, "Alarm Management: Seven Effective Methods for Optimum Performance", ISA, 2007

1. What you see Alarm GUI used by Operators 5 Managed by UT-Battelle

What you see: Alarm Table All current alarms new, ack ed Sort by PV, Descr., Time, Severity, Optional: Annunciate Acknowledge one or multiple alarms Select by PV or description BNL/RHIC type un-ack 6 Managed by UT-Battelle

Another View: Alarm Tree All alarms Disabled, inactive, new, ack ed Hierarchical Optionally only show active alarms Ack /Un-ack PVs or sub-tree 7 Managed by UT-Battelle

Guidance, Related Displays, Commands Basic Text Open EDM/OPI screen Open web page Run ext. command Hierarchical: Including info of parent entries 8 Managed by UT-Battelle Merges Guidance etc. from all selected alarms

Integrated with other CSS Tools Alarms History of PV EPICS Config. 9 Managed by UT-Battelle

CSS Context Menus Connect the Tools Send alarm PV to any other CSS PV tool 10 Managed by UT-Battelle

E-Log Entries Logbook from context menu creates text w/ basic info about selected alarms. Edit, submit. Pluggable implementation, not limited to Oracle-based SNS ELog 11 Managed by UT-Battelle

Online Configuration Changes.. may require Authentication/Authorization Log in/out while CSS is running 12 Managed by UT-Battelle

Add PV or Subsystem 1. Right-click on parent 2. Add 3. Enter name Online. No search for config files, no restarts. 13 Managed by UT-Battelle

Configure PV Again online Especially useful for operators to update guidance and related screens. 14 Managed by UT-Battelle

2. Technical details Behind the GUI; Tools to monitor performance 15 Managed by UT-Battelle

Technical View IOCs PV Updates (Channel Access, ) Alarm Server Current Alarms: Acknowledged? Transient? Annunciated? Tomcat - Reports Log Messages Annunciations Alarm Updates Ack ; Config Updates LOG TALK JMS ALARM_SERVER ALARM_CLIENT Alarm Cfg & State RDB JMS 2 RDB JMS 2 Speech Alarm Client GUI Message RDB CSS Applications 16 Managed by UT-Battelle

General Alarm Server Behavior Latch highest severity, or non-latching like ALH ack. transient Annunciate Chatter filter ala ALH Alarm only if severity persists some minimum time.. or alarm happens >=N times within period Optional formula-based alarm enablement: Enable if (pv_x > 5 && pv_y < 7) pv_z==1 but we prefer to move that logic into IOC When acknowledging MAJOR alarm, subsequent MINOR alarms not annunciated ALH would again blink/require ack 17 Managed by UT-Battelle

Logging..into generic CSS log also used for error/warn/ info/debug messages Alarm Server: State transitions, Annunciations Alarm GUI: Ack/Un-Ack requests, Config changes Generic Message History Viewer Example w/ Filter on TEXT=CONFIG 18 Managed by UT-Battelle

Logging: Get timeline Example: Filter on TYPE, PV 6. All OK 4. Problem fixed 5. Ack ed by operator 3. Alarm Server annunciates 2. Alarm Server latches alarm 1. PV triggers, clears, triggers again 19 Managed by UT-Battelle

All Sorts of Web Reports 20 Managed by UT-Battelle

3. How to use it This may be more important than the tools! 21 Managed by UT-Battelle

Best Ever Alarm System Tools, Indeed.. but Tools are only half the issue Good configuration requires plan & follow-up. B. Hollifield, E. Habibi, "Alarm Management: Seven (??) Effective Methods for Optimum Performance", ISA, 2007 22 Managed by UT-Battelle

Alarm Philosophy Goal: Help operators take correct actions Alarms with guidance, related displays Manageable alarm rate (<150/day) Operators will respond to every alarm (corollary to manageable rate) 23 Managed by UT-Battelle

What s a valid alarm? DOES IT REQUIRE IMMEDIATE OPERATOR ACTION? What action? Alarm guidance! Not make elog entry, tell next shift, Consider consequence of no action Is it the best alarm? Would other subsystems, with better PVs, alarm at the same time? 24 Managed by UT-Battelle

How are alarms added? Alarm triggers: PVs on IOCs But more than just setting HIGH, HIHI, HSV, HHSV HYST is good idea Dynamic limits, enable based on machine state,... Requires thought, communication, documentation Added to alarm server with Guidance: How to respond Related screen: Reason for alarm (limits, ), link to screens mentioned in guidance Link to rationalization info (wiki) 25 Managed by UT-Battelle

Impact/Consequence Grid Category So What Minor Consequence Major Consequence Personnel Safety PPS independent from EPICS? Environment, Public Can EPICS cause contained spill of mercury? Uncontained spill?? Cost: Beam Production, Downtime, Beam Quality No effect Beam off < 1 sec? Beam off <10 min <$10000 Beam off >10min >$10000 Mostly: How long will beam be off? 26 Managed by UT-Battelle

.. combined with Response Time Time to Respond Minor Consequence Major Consequence >30 Minutes NO_ALARM MINOR 10..30 minutes MINOR MAJOR <10 minutes MAJOR MAJOR + Annunciate This part is still evolving 27 Managed by UT-Battelle

Example: Elevated Temp/Press/Res.Err./ Immediate action required? Do something to prevent interlock trip Impact, Consequence? Beam off: Reset & OK, 5 minutes? Cryo cold box trip: Off for a day? Time to respond? 10 minutes to prevent interlock? MINOR? MAJOR? Guidance: Open Valve 47 a bit, Related Displays: Screen that shows Temp, Valve, 28 Managed by UT-Battelle

Safety System Alarms Protection Systems not per se high priority Action is required, but we re safe for now, it won t get worse if we wait Pick One Mommy, I need to gooo! Mommy, I went (Does it require operator action? How much time is there?) 29 Managed by UT-Battelle

Avoid Multiple Alarm Levels Analog PVs for Temp/Press/Res.Err./ : Easy to set LOLO, LOW, HIGH, HIHI Consider: In most cases, HIGH & HIHI only double the alarm traffic Set only HSV to generate single, early alarm Adding HHSV alarm assuming that the first one is ignored only worsens the problem 30 Managed by UT-Battelle

Bad Example: Old SNS MEBT Alarms Each amplifier trip: 3 ~identical alarms, no guidance Rethought w/ subsystem engineer, IOC programmer and operators: 1 better alarm 31 Managed by UT-Battelle

Alarms for Redundant Pumps 32 Managed by UT-Battelle

Alarm Generation: Redundant Pumps the wrong way Control System Pump1 on/off status Pump2 on/off status Simple Config setting: Pump Off => Alarm: It s normal for the backup to be off Both running is usually bad as well Except during tests or switchover During maintenance, both can be off 33 Managed by UT-Battelle

Redundant Pumps Required Pumps: 1 Control System Pump1 on/off status Pump2 on/off status Number of running pumps Configurable number of desired pumps Alarm System: Running == Desired? with delay to handle tests, switchover Same applies to devices that are only needed on-demand 34 Managed by UT-Battelle

Weekly Review: How Many? Top 10? 35 Managed by UT-Battelle

A lot of information available How often did PV trigger? For how long? When? Temporary issue? Or need HYST, alarm delay, fix to hardware? 36 Managed by UT-Battelle

Weekly Check: Stale, Forgotten? 37 Managed by UT-Battelle

Summary BEAST operational since Feb 09 Needs a logo For now without BEAUtY DESY AMS is similar and has been operational for longer Pick either, but good configuration requires work in any case Started with previous annunciated alarms ~300, no guidance, no related displays Now ~330, all with guidance, rel. displays Philosophy helps decide what gets added and how Immediate Operator Action? Consequence? Response Time? Weekly review spots troubles and tries to improve configuration 38 Managed by UT-Battelle