Split System Cooling Product Data

Similar documents
SPLIT SYSTEM COOLING 1 1 / 2 5 TON MODELS 4A7A

Split System Cooling Product Data

Split System Cooling Product Data

Split System Cooling Product Data

AMERICAN STANDARD 14 MODELS 4A7B E

Split System Cooling Product Data

Split System Heat Pump Product Data

SPLIT SYSTEM COOLING 2, 3, 4 & 5 TON MODEL 4A7A American Standard Heating & Air Conditioning

Split System Cooling Product Data

Split System Cooling Product Data

Split System Heat Pump Product Data

Split System Heat Pump Product Data

Split System Cooling Product Data

Split System Cooling Product Data

Split System Cooling Product Data

Split System Heat Pump Product Data

Split System Heat Pump Product Data

Split System Cooling Product Data

Split System Cooling Product & Performance Data

SPLIT SYSTEM HEAT PUMP 1½ 5 TON HERITAGE 13 MODELS 2A6H A American Standard Heating & Air Conditioning

Split System Heat Pump Product & Performance Data

Split System Cooling Product Data

Split System Heat Pump Product Data

SPLIT SYSTEM HEAT PUMP 2, 3, 4 & 5 ton HERITAGE 20 MODELS 4A6Z0024, 036, 048, & 060A. with AccuLink and Charge Assist

SPLIT SYSTEM COOLING 1½ 5 TON ALLEGIANCE 14 MODELS 4A7A C/30-060B American Standard Heating & Air Conditioning

Product Data. Split System Cooling D-EN. August 2016

Product Data. Split System Heat Pump B-EN. February A6H6024H1000A

Product Data. Split System Cooling A. November 2013

Product Data. Split System Heat Pump A-EN. March 2016

Product Data. Split System Heat Pump D-EN. February 2016

Product Data. Split System Cooling H-EN. January 2017

Product Data. Split System Cooling E-EN. November 2016

Appendix J Noise Appendix

Product Data. Split System Heat Pump 4TWR4018G1000A 4TWR4024G1000A 4TWR4030G1000A 4TWR4036G1000A 4TWR4042G1000A 4TWR4048G1000A 4TWR4060G1000A

Hyperion TM Split Systems

Product Data. Split System Heat Pump

Product Data Split System Cooling

Split System Cooling Product & Performance Data

Product Data. Side Discharge AC Models 4TTL6018A1000A 4TTL6024A1000A 4TTL6030A1000A 4TTL6036A1000A 4TTL6042A1000A 4TTL6048A1000A 4TTL6060A1000A

Illusion Split System

Product catalog. Hyperion TM split systems 60 Hz / R410A / 13 SEER SSA-PRC009-E4

Submittal. Split System Cooling 4A7A6024J-SUB-1B-EN. January A7A6024J1000B TAG:

Split System Heat Pump Product Data

Submittal. Split System Cooling 5.0 Ton 4A7A3060D1000P TAG:

Service Facts. WARNING: HAZARDOUS VOLTAGE - DISCONNECT POWER and DISCHARGE 4TTB6-SF-3. Split System Cooling 4TTB6048A1000A, 4TTB6049A1000A CAUTION

Submittal. Date: January 8, Customer P.O. Number: Customer Project Number: CARROLLTON, TX 75006

4TTB3030D1000B 208/230/1/60 4TTB3036D1000B 208/230/1/ RECIP /230/1/ RECIP YES YES

4TTB3060D1000B 208/230/1/60 35 SCROLL /230/1/ /8

7/8 NO NO NO PROPELLER DIRECT / /230/1/ SPINE FIN /8 8 LBS., 0 OZ. YES 7/8 3/8

208/230/1/ CLIMATUFF /230/1/ YES NO NO PROPELLER 23-1 DIRECT / /230/1/ SPINE FIN

TruComfort Variable Speed Cooling Single Phase 2-5 Tons

Uncased Vertical Aluminum Upflow Cooling/HP Coils 2-5 Ton 4PXA. Heat Pump / Cooling Coils for R-410A PUB. NO

Service Facts. WARNING: HAZARDOUS VOLTAGE - DISCONNECT POWER and DISCHARGE 4TTR6024-SF-1B. Split System Cooling 4TTR6024A1000B CAUTION CAUTION WARNING

Split System Cooling Product Data XB 1000

4A6H5042G1000A 208/230/1/ DURATION - SCROLL 3/4 208/230/1/ NO (Use BAYKSKT263) YES YES PROPELLER DIRECT

4TTR6036B1000A 208/230/1/ CLIMATUFF - SCROLL 3/4 3/4 3/4 3/4 3/4 208/230/1/ NO YES NO PROPELLER DIRECT

Service Facts. WARNING: HAZARDOUS VOLTAGE - DISCONNECT POWER and DISCHARGE 4TTR6048-SF-1A. Split System Cooling 4TTR6048A1000A CAUTION CAUTION WARNING

36,000-62,000 BTUH Nominal Capacity

4A6H5049E1000B 208/230/1/ /8 7/8 7/8 7/8 DURATION 208/230/1/ /230/1/ SPINE FIN 13 LBS., 10 OZ. YES

Commercial High-Efficiency Condensing Units

208/230/1/60 5/8 5/8 5/8 5/8 5/8 20 CLIMATUFF /230/1/

MACH N-407 Heat Pump Air-Cooled Chiller

Aluminum Cased Heat Pump / Cooling Coils 2-5 Ton

Service Facts. Split System Cooling 3.0 Ton 4A7A6036J-SF-1B-EN. January A7A6036J1000A

Cooling/Heat Pump Convertible Air Handlers

UP TO 17.5 SEER / 13.5 EER / 9.5 HSPF HEAT PUMP ENVIRONMENTALLY BALANCED R- 410A REFRIGERANT 2 THRU 5 TONS SPLIT SYSTEM

WCH5**4. Product Specifications

MERIT Series R-410A. SEER up to to 5 Tons Cooling Capacity - 17,500 to 59,000 Btuh AIR CONDITIONERS 13ACXN PRODUCT SPECIFICATIONS

N4H4. Product Specifications 14 SEER HEAT PUMP. ENVIRONMENTALLY SOUND R 410A REFRIGERANT 1½ THRU 5 TONS SPLIT SYSTEM 208 / 230 Volt, 1 phase, 60 Hz

Cooling/Heat Pump Convertible Air Handlers

R4H4. Product Specifications

TECHNICAL SPECIFICATIONS

ELITE Series R-410A. SEER up to to 5 Tons Cooling Capacity - 17,800 to 60,000 Btuh AIR CONDITIONERS EL16XC1 PRODUCT SPECIFICATIONS

TECHNICAL GUIDE. Description SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS YD360, 480 & THRU 50 NOMINAL TONS YTG-B-0811

TECHNICAL GUIDE DESCRIPTION SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS MODELS: HF-07 FEATURES B-0703

R4H4. Product Specifications

DRY CHARGE UNITS. 1.5 to 5 Tons. HEAT PUMP OUTDOOR UNITS lps13dc PRODUCT SPECIFICATIONS L P S 13 DC MODEL NUMBER IDENTIFICATION

MAC N-407 Air-Cooled Chiller

2 shp 13 lc 1 36 t - 1 a

Ruud Achiever Series Air Conditioners

2TEH3F18A1000A 2TEH3F24A1000A 2TEH3F30A1000A 2TEH3F36A1000A 2TEH3F42A1000A 2TEH3F48A1000A 2TEH3F60A1000A 1½

TECHNICAL GUIDE LISTED. SPLIT-SYSTEM AIR CONDITIONERS 10 SEER R22 60Hz MODELS: AC036X10(3,4) THRU 060 (3 THRU 5 NOMINAL TONS, 3 PH) DESCRIPTION

Cooling/Heat Pump Convertible Air Handlers

Aluminum Cased and Uncased Heat Pump / Cooling Coils 1 1/2-5 Ton 2/4TXA, 2/4TXC PUB. NO Heat Pump /Cooling Coils for R-22 and R-410A

NH4H4. Product Specifications 14 SEER HORIZONTAL DISCHARGE HEAT PUMP FOR USE WITH DUCTED INDOOR UNIT

DRY CHARGE UNITS. 1.5 to 5 Tons AIR CONDITIONERS LCS13DC PRODUCT SPECIFICATIONS L C S 13 DC MODEL NUMBER IDENTIFICATION

Product Data PH13(N,P)R FEATURES AND BENEFITS. SPLIT SYSTEM HEAT PUMP For Use With R Refrigerant 1---1/2 TO 5 TONS ( )

N4H4. Product Specifications

TECHNICAL GUIDE LISTED. SPLIT-SYSTEM AIR CONDITIONERS 10 SEER R22 60Hz MODELS: H*BA-(T,W)036 THRU 076 (3 THRU 6.3 NOMINAL TONS, 3 PH) DESCRIPTION

MAC-120HE-03 Air-Cooled Chiller

Commercial High-Efficiency Condensing Units

MHNCCW (4-Pipe) Chilled/Hot Water Ceiling Concealed 208/230V 4-Pipe Heating & Cooling Fan Coil 12,000 BTUH

PRODUCT SPECIFICATIONS 2YCC3048A1120A /1/ /

TECHNICAL GUIDE DESCRIPTION SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS. HA300, HB360, HB480 & HB thru 50 NOMINAL TONS (50 Hz)

PRODUCT SPECIFICATIONS

4HP15L PRODUCT SPECIFICATIONS HIGH EFFICIENCY SPLIT HEAT PUMP SYSTEM UP TO 15 SEER & 9.0 HSPF COILS COMPONENTS COMPRESSOR WARRANTY CABINET DESIGN

TECHNICAL SPECIFICATIONS

3 to 5 Tons. AIR CONDITIONERS 2scu13. Dry Charge Split System - 60 HZ PRODUCT SPECIFICATIONS. 2 scu 13 lc 1 36 t - 1 a MODEL NUMBER IDENTIFICATION

PAJ3. Product Specifications

PRODUCT SPECIFICATIONS 2YCC3036A1096A /1/ /

Transcription:

Split System Cooling Product Data XB16 4TTB6 1 1 / 2-5 Tons PUB. NO. 22-1888-01

Features and Benefits Efficiency up to 16.0 SEER All aluminum SPINE FIN coil WEATHERGUARD fasteners QUICK-SESS cabinet, service access and refrigerant connections with full coil protection DURATUFF base, fast complete drain, weatherproof COMFORT-R mode approved Glossy corrosion resistant finish Internal compressor high/low pressure & temperature protection 018, 024 & 030 ship with start kit Liquid line filter/drier Polyslate gray cabinet with anthracite gray badge and cap High pressure switch R-410A refrigerant S.E.E.T. design testing 100% line run test Low ambient cooling to 30 F with AY28X079 Low ambient cooling to 55 F as shipped Extended warranties available 2013 Trane 2 22-1888-01

Features and Benefits 2 General Data 4 Product Specifications 4 A-Weighted Sound Power Level [db(a)] 4 Accessory Description and Usage 6 AHRI Standard Capacity Rating Conditions 6 Model Nomenclature 7 Electrical Data 8 Dimensions 13 Mechanical Specification Options 16 22-1888-01 3

General Data Product Specifications Model No. 1 4TTB6018A1000A 4TTB6024A1000A 4TTB6030A1000A 4TTB6036A1000A Electrical Data V/Ph/Hz 2 208/230/1/60 208/230/1/60 208/230/1/60 208/230/1/60 Min Cir Ampacity 9 9 15 19 Max Fuse Size (Amps) 15 15 25 30 Compressors RECIP RECIP RECIP SCROLL No. Used - No. Stages 1-1 1-1 1-1 1-1 RL AMPS - LR AMPS 6.4-39 6.8-38.6 11.5-63.5 14.1-77 Outdoor Fan FL Amps 0.74 0.74 1.2 0.93 Fan HP 1/8 1/8 1/5 1/5 Fan Dia (inches) 23 23 27.6 27.6 Coil Spine Fin Spine Fin Spine Fin Spine Fin Refrigerant R-410A 5/2-LB/OZ 6/3-LB/OZ 7/0-LB/OZ 7/4-LB/OZ Line Size - (in.) O.D. Gas 3 5/8 3/4 3/4 3/4 Line Size - (in.) O.D. Liquid 3 3/8 3/8 3/8 3/8 Dimensions H x W x D (Crated) 34 x 30.1 x 33 34 x 30.1 x 33 38.4 x 35.1 x 38.7 42.4 x 35.1 x 38.7 Weight - Shipping 200 201 234 228 Weight - Net 173 174 201 193 Start Components YES YES YES NO Sound Enclosure YES YES YES NO Compressor Sump Heat NO NO NO NO Optional Accessories: 4 Anti-short Cycle Timer TAYASCT501A TAYASCT501A TAYASCT501A TAYASCT501A Evaporator Defrost Control A/C AY28X079 AY28X079 AY28X079 AY28X079 Rubber Isolator Kit BAYISLT101 BAYISLT101 BAYISLT101 BAYISLT101 Crank Case Heater Kit BAYCCHT300 BAYCCHT300 BAYCCHT300 BAYCCHT302 Hard Start Kit Scroll BAYKSKT260 Extreme Condition Mounting Kit BAYECMT023 BAYECMT023 BAYECMT004 BAYECMT004 Snow Leg - Base & Cap 4" High BAYLEGS002 BAYLEGS002 BAYLEGS002 BAYLEGS002 Snow Leg - 4" Extension BAYLEGS003 BAYLEGS003 BAYLEGS003 BAYLEGS003 Seacoast Kit BAYSEAC001 BAYSEAC001 BAYSEAC001 BAYSEAC001 Refrigerant Lineset 5 TAYREFLN950 TAYREFLN7* TAYREFLN7* TAYREFLN7* 1 Certified in accordance with the Air-Source Unitary Heat Pump Equipment certification program which is based on AHRI Standard 210/240. 2 Calculated in accordance with N.E.C. Only use HACR circuit breakers or fuses. Model A-Weighted Sound Power Level [db(a)] Sound Power Level 3 Standard line lengths - 80'. Standard lift - 60' Suction and Liquid line. For Greater lengths and lifts refer to refrigerant piping software Pub# 32-3312-0. ( denotes latest revision) 4 For accessory description and usage, see pages 5 and 6. 5 * = 15, 20, 25, 30, 40 and 50 foot lineset available. Full Octave Sound Power [db] 63 Hz 125 Hz 250 Hz 500 Hz 1000 Hz 2000 Hz 4000 Hz 8000 Hz 4TTB6018A1 79 51 61 65 74 74 72 61 51 4TTB6024A1 79 49 62 66 74 74 69 62 54 4TTB6030A1 80 54 69 72 78 76 72 64 54 4TTB6036A1 78 49 68 73 76 74 70 62 51 4TTB6042A1 80 49 69 74 77 75 70 62 51 4TTB6048A1 80 49 69 74 77 75 70 62 51 4TTB6049A1 76 71 70 65 67 35 59 52 45 4TTB6060A1 80 49 69 74 77 75 70 62 51 4TTB6061A1 76 68 70 66 69 66 57 57 53 Note: Rated in accordance with AHRI Standard 270-2008 4 22-1888-01

General Data Product Specifications Model No. 1 4TTB6042A1000A 4TTB6048A1000A 4TTB6049A1000A 4TTB6060A1000A 4TTB6061A1000A Electrical Data V/Ph/Hz 2 208/230/1/60 208/230/1/60 208/230/1/60 208/230/1/60 230/1/60 Min Cir Ampacity 23 26 26 34 37 Max Fuse Size (Amps) 40 45 45 60 60 Compressors SCROLL SCROLL SCROLL SCROLL SCROLL No. Used - No. Stages 1-1 1-1 1-1 1-1 1-2 RL AMPS - LR AMPS 17.9-112 19.9-109 19.9-109 26.4-134 28.8-152.9 Outdoor Fan FL Amps 0.93 0.93 1.0 0.93 2.80 Fan HP 1/5 1/5 1/5 1/5 1/3 Fan Dia (inches) 27.6 27.6 27.6 27.6 27.6 Coil Spine Fin Spine Fin Spine Fin Spine Fin Spine Fin Refrigerant R-410A 8/4-LB/OZ 8/5-LB/OZ 11/9-LB/OZ 8/8-LB/OZ 12/9-LB/OZ Line Size - (in.) O.D. Gas 3 7/8 7/8 7/8 7/8 1-1/8 Line Size - (in.) O.D. Liquid 3 3/8 3/8 3/8 3/8 3/8 Dimensions H x W x D (Crated) 46.4 x 35.1 x 38.7 51 x 35.1 x 38.7 51 x 35.1 x 38.7 51 x 35.1 x 38.7 51 x 35.1 x 38.7 Weight - Shipping 272 282 304 285 312 Weight - Net 235 245 267 248 275 Start Components NO NO NO NO NO Sound Enclosure NO NO NO NO NO Compressor Sump Heat NO NO NO NO NO Optional Accessories: 4 Anti-short Cycle Timer TAYASCT501A TAYASCT501A TAYASCT501A TAYASCT501A TAYASCT501A Evaporator Defrost Control A/C AY28X079 AY28X079 AY28X079 AY28X079 AY28X079 Rubber Isolator Kit BAYISLT101 BAYISLT101 BAYISLT101 BAYISLT101 BAYISLT101 Crank Case Heater Kit BAYCCHT301 BAYCCHT301 BAYCCHT301 BAYCCHT301 BAYCCHT301 Hard Start Kit Scroll BAYKSKT260 BAYKSKT260 BAYKSKT260 BAYKSKT263 Extreme Condition Mounting Kit BAYECMT004 BAYECMT004 BAYECMT004 BAYECMT004 BAYECMT004 Snow Leg - Base & Cap 4" High BAYLEGS002 BAYLEGS002 BAYLEGS002 BAYLEGS002 BAYLEGS002 Snow Leg - 4" Extension BAYLEGS003 BAYLEGS003 BAYLEGS003 BAYLEGS003 BAYLEGS003 Seacoast Kit BAYSEAC001 BAYSEAC001 BAYSEAC001 BAYSEAC001 BAYSEAC001 Refrigerant Lineset 5 TAYREFLN3* TAYREFLN3* TAYREFLN3* TAYREFLN3* TAYREFLN*4 1 Certified in accordance with the Air-Source Unitary Heat Pump Equipment certification program which is based on AHRI Standard 210/240. 2 Calculated in accordance with N.E.C. Only use HACR circuit breakers or fuses. 3 Standard line lengths - 60'. Standard lift - 60' Suction and Liquid line. For 061 units, Max. linear length 60 ft.; Max. lift - Suction 25 ft.; Max lift - Liquid 25 ft. For Greater lengths and lifts refer to refrigerant piping software Pub# 32-3312-0. ( denotes latest revision) 4 For accessory description and usage, see pages 5 and 6. 5 * = 15, 20, 25, 30, 40 and 50 foot lineset available. 22-1888-01 5

General Data Accessory Description and Usage Anti-Short Cycle Timer Solid state timing device that prevents compressor recycling until 5 minutes have elapsed after satisfying call or power interruptions. Use in area with questionable power delivery, commercial applications, long lineset, etc. Evaporator Defrost Control SPST Temperature actuated switch that cycles the condenser off as indoor coil reaches freeze-up conditions. Used for low ambient cooling to 30 F with TXV. Rubber Isolators 5 large rubber donuts to isolate condensing unit from transmitting energy into mounting frame or pad. Use on any application where sound transmission needs to be minimized. Hard Start kit Start capacitor and relay to assist compressor motor startup. Use in areas with marginal power supply, on long linesets, low ambient conditions, etc. Extreme Condition Mount Kit Bracket kits to securely mount condensing unit to a frame or pad without removing any panels. Use in areas with high winds, or on commercial roof tops, etc. AHRI Standard Capacity Rating Conditions AHRI STANDARD 210/240 RATING CONDITIONS (A) Cooling 80 F DB, 67 F WB air entering indoor coil, 95 F DB air entering outdoor coil. AHRI STANDARD 270 RATING CONDITIONS (Noise rating numbers are determined with the unit in cooling operation.) Standard Noise Rating number is at 95 F outdoor air. 6 22-1888-01

Model Nomenclature Outdoor Units 4 T T B 6 0 3 6 A 1 0 0 0 A A Air Handler G A M 5 A 0 B 3 6 M 3 1 S A A Refrigerant Type 2 = R-22 4 = R-410A TRANE Product Type W = Split Heat Pump T = Split Cooling Product Family Z = Leadership Two Stage X = Leadership R = Replacement/Retail B = Basic A = Light Commercial Family SEER 0 = 10 3 = 13 6 = 16 1 = 11 4 = 14 8 = 18 2 = 12 5 = 15 9 = 19 Split System Connections 1-6 Tons 0 = Brazed Nominal Capacity in 000s of BTUs Major Design Modifications Power Supply 1 = 200-230/1/60 or 208-230/1/60 3 = 200-230/3/60 4 = 460/3/60 Secondary Function Minor Design Modifications Unit Parts Identifier Gas Furnaces Furnace Configuration TU = Upflow/Horizontal TD = Downflow/Horizontal Type E = 80% Induced Draft Standard D = 80% Induced Draft Premium C = 90% Condensing Standard X = 90% Condensing Premium H = 95% Condensing Premium Number of Heating Stages 1 = Single Stage 2 = Two Stage M = Modulating Cabinet Width A = 14.5" Cabinet Width B = 17.5" Cabinet Width C = 21.0" Cabinet Width D = 24.5" Cabinet Width Heating Input in 1000 s (BTUH) 080 = 80,000 BTUH Major Design Change T U D 1 B 0 8 0 A 9 H 3 1 A A Voltage 9 = 115 Volts / 60 Hertz / Natural Gas A = 115 Volts / 50 Hertz / Natural Gas C = 115 Volts / Natural Gas with Communicating System Control F = 115 Volts / Natural Gas with Integrated Electronic Filter D = 115 Volts / Natural Gas with Communicating System Control and Integrated Electronic Filter Air Capacity for Cooling Standard PSC Variable Speed High Efficiency 24 = 2 Tons V3 = 3 Tons H3 = 3 Tons 36 = 3 Tons V4 = 4 Tons H4 = 4 Tons 42 = 3.5 Tons V5 = 5 Tons H5 = 5 Tons 45 = 4 Tons 48 = 4 Tons 54 = 5 Tons 60 = 5 Tons 72 = 6 Tons Draft Inducer Speeds 1 = Single Speed 2 = Two Speed V = Variable Speed Minor Design Change Service Digit - Not Orderable 22-1888-01 7 Brand T = Better G = Good Product Type A = Air Handler Convertability M = Multi-poise 4-way F = Upflow Front Return, 3-way T = 3-way Product Tier 2 = Good, Entry Level Feature Set 4 = Better, Retail Replacement Mid Effy. 5 = Better, Entry Level High Effy., Multi-Speed 7 = Best, Retail Replacement High Effy., Variable-Speed 8 = Best, Retail Ultimate High Effy., Variable-Speed Major Design Change No Descriptor 0 = Air Handler / Coil Size (Footprint) A = 17.5 x 21.5 B = 21.0 x 21.5 C = 23.5 x 21.5 Cooling Size: Air Handler or Coil 0-9 = AH Coil - 1000 BTU s (18, 24, 30, 36, 42, 48, 60) Airflow Type & Capability S = Low Effy PSC, 1-5 - nom. Tonnage (cfm/ton) M = Mid Effy Multi-Speed, 1-5 - nom. Tonnage (cfm/ton) H = High Effy Multi-Speed, 1-5 - nom. Tonnage (cfm/ton) V = High Effy Variable, 1-5 - nom. Tonnage (cfm/ton) Power Supply 1 = 208-230/1/60 System Control Type S = Standard - 24 VAC C = CLII 13.8 VDC Minor Design Change Unit Parts Identifier Heat Pump/ Cooling Coils Refrigerant Type 4 = R-410A Series T = Premium (Heat Pump or Convertible Coil) C = Standard (Cooling Only) Coil Design X = Direct Expansion Evaporator Coil Coil Feature C = Cased A Coil A = Uncased A Coil F = Cased Horizontal Flat Coil Coil Width (Cased/Uncased) A = 14.5" /13.3" B = 17.5" / 16.3" C = 21.0" / 19.8" D = 24.5" / 23.3" H = 10.5" Refrigerant Line Coupling 0 = Brazed Nominal Capacity in 1000's (BTUH) Major Design Change Efficiency C = Standard S = Hi Efficiency (derived from 10 SEER products) Refrigerant Control 3 = TXV - Non-Bleed Coil Circuitry H = Heat Pump C = Cooling Airflow Configuration A = Upflow Only U = Upflow / Downflow H = Horizontal Only C = Convertible - Upflow, Downflow, Left or Right Airflow Minor Design Change Service Digit - Not Orderable 4 T X C B 0 3 6 A C 3 H C A A

Electrical Data Schematic Diagrams 4TTB6018, 4TTB6024, 4TTB6030 From Drawing D157123P01REV0 8 22-1888-01

Electrical Data Schematic Diagrams 4TTB6036, 4TTB6042 From Drawing D157124P01 22-1888-01 9

Electrical Data Schematic Diagrams 4TTB6048, 4TTB6049 From Drawing D157125P01 10 22-1888-01

Electrical Data Schematic Diagrams 4TTB6060 From Drawing D157126P01 22-1888-01 11

Electrical Data Schematic Diagrams 4TTB6061 From Drawing D157615p01 12 22-1888-01

Dimensions 4TTB6 Outline Drawing Note: All dimensions are in MM (Inches). MODELS BASE A B C D E F G H J K 4TTB6018A 3 730 (28-3/4) 829 (32-5/8) 756 (29-3/4) 5/8 3/8 127 (5) 76 (3) 197 (7-3/4) 57 (2-1/4) 508 (20) 4TTB6024A 3 730 (28-3/4) 829 (32-5/8) 756 (29-3/4) 3/4 3/8 127 (5) 76 (3) 197 (7-3/4) 57 (2-1/4) 508 (20) 4TTB6030A 4 841 (33-1/8) 946 (37-1/4) 870 (34-1/4) 3/4 3/8 152 (6) 98 (3-7/8) 219 (8-5/8) 86 (3-3/8) 508 (20) 4TTB6036A 4 943 (37-1/8) 946 (37-1/4) 870 (34-1/4) 3/4 3/8 152 (6) 98 (3-7/8) 219 (8-5/8) 86 (3-3/8) 508 (20) 4TTB6042A 4 1045 (41 1/8) 946 (37-1/4) 870 (34-1/4) 7/8 3/8 152 (6) 98 (3-7/8) 219 (8-5/8) 86 (3-3/8) 508 (20) 4TTB6048A 4 1147 (45 1/8) 946 (37-1/4) 870 (34-1/4) 7/8 3/8 152 (6) 98 (3-7/8) 219 (8-5/8) 86 (3-3/8) 508 (20) 4TTB6049A 4 1147 (45 1/8) 946 (37-1/4) 870 (34-1/4) 7/8 3/8 152 (6) 98 (3-7/8) 219 (8-5/8) 86 (3-3/8) 508 (20) 4TTB6060A 4 1147 (45 1/8) 946 (37-1/4) 870 (34-1/4) 7/8 3/8 152 (6) 98 (3-7/8) 219 (8-5/8) 86 (3-3/8) 508 (20) 4TTB6061A 4 1147 (45 1/8) 946 (37-1/4) 870 (34-1/4) 1-1/8 3/8 152 (6) 98 (3-7/8) 219 (8-5/8) 86 (3-3/8) 508 (20) From Dwg. D156010 22-1888-01 13

Notes 14 22-1888-01

Notes 22-1888-01 15

Mechanical Specification Options General The 4TTB6 is fully charged from the factory for up to 15 feet of piping. This unit is designed to operate at outdoor ambient temperatures as high as 115 F. Cooling capacities are matched with a wide selection of air handlers and furnace coils that are AHRI certified. The unit is certified to UL 1995. Exterior is designed for outdoor application. Casing Unit casing is constructed of heavy gauge, G90 galvanized steel and painted with a weather-resistant powder paint on all louvers, panels, prepaint on all other panels. Corrosion and weatherproof CMBP-G30 DuraTuff base. Refrigerant Controls Refrigeration system controls include condenser fan and compressor contactor. High and low pressure controls are inherent to the compressor. A factory installed liquid line drier is standard. Compressor The compressor features internal over temperature and pressure protection and total dipped hermetic motor. Other features include: roto lock suction and discharge refrigerant connections, centrifugal oil pump and low vibration and noise. Condenser Coil The outdoor coil provides low airflow resistance and efficient heat transfer. The coil is protected on all four sides by louvered panels. Low Ambient Cooling As manufactured, this unit has a cooling capability to 55 F. The addition of an evaporator defrost control with TXV permits low ambient cooling to 30 F. Accessories Thermostats Cooling only and heat/cooling (manual and automatic changeover). Sub-base to match thermostat and locking thermostat cover. Trane www.trane.com The manufacturer has a policy of continuous product and product data improvement and it reserves the right to change design and specifications without notice. 05/13