Overview of Standards for CO Detection Products

Similar documents

Navigating The Product Certification Maze: Building Codes and Product Standards. AGENDA be Covered

Setting the Standard in Third-party Certification

NEMA Applications Guide

AUGUST 2016 CONTENTS:

Guidelines for the Design Engineer

Hydrogen Equipment Certification Guide. Listing, Labeling, and Approval Considerations

Certification Supplement Manual

International Product Compliance and Certifications. Product Safety Consulting, Inc.

Navigating the Safety Certification Process for LED Lighting Products Todd Straka, Director Lighting Services

Products Solutions Services CT287. Hazardous Area Classifications and Protection Systems

CE marking & your legal obligations

Guide to Hazardous Location Approvals: MICRO SWITCH Hazardous Area Limit Switches

Guide to Hazardous Location Approvals:

Executive Summary. Shell Offshore Inc. BY: Keith M. Gonzales Sr., P.E. Regulatory Requirements for Hazardous Locations

Medical devices and electromagnetic compatibility. Addressing the requirements of IEC , 4 th Edition

BUSINESS PLAN CEN/TC 305 POTENTIALLY EXPLOSIVE ATMOSPHERES EXPLOSION PREVENTION AND PROTECTION EXECUTIVE SUMMARY

CE Marking and Technical Standardisation

User Manual. PolyGard CO LC-1112 V3. Electrochemical analog carbon monoxide transmitters serial no. EC-S 002. August 29, 2006

SPECIFICATION MODEL 5200 GAS MONITOR SYSTEM. User Instructions For The Model 5200 Gas Monitor System

Integrating Fire and Gas Safety with Process Control Systems:

Intrinsically Safe Transmitters, Option Code 2n

Instruction Manual. CAT 100 & CAT 200 Continuous Analyzer Transmitter Addendum for Hazardous Area Applications. 3 rd Edition 05/2007

Case Study. INTEGRATING Fire & GAS SAFETY WITH PROCESS CONTROL SYSTEMS

Certification Supplement Manual

Carbon Monoxide Detection in Buildings Frequently Asked Questions

Hydrogen Sensor Testing and Certification Underwriters Laboratories Inc.

Certificate of Compliance

Valve Manufacturers Association of America

Legislation, Standards and Technology. Figure 1: 1897 Approved Electrical Fittings

INTERNATIONAL STANDARD

Certificate of Compliance

Energy Efficiency Schemes Brief Introduction

SAFETY MANUAL. Electrochemical Gas Detector GT3000 Series Includes Transmitter (GTX) with H 2 S or O 2 Sensor Module (GTS)

New Legal Framework Carlo Casati

Session Eight: It s Not Rocket Science Unless You Do It Wrong

CE marking & your legal obligations

The Process of making European Standards. Frank Moore Chairman CEN TC/248 Textiles

Understanding Hazardous Locations Concepts

FINAL REPORT ON THE 4 TH JOINT CROSS-BORDER EMC MARKET SURVEILLANCE CAMPAIGN (2011) LED LIGHTING PRODUCTS

Safety Evaluation of Luminaires and Self Ballasted Lamps. 1

Transition to a New Hazard Based Safety Standard, IEC

Compilation of regulatory approaches used in various countries. Information received by the Secretariat through a survey in 2009

INTERNATIONAL STANDARD

The European Standardization System. Diana Dus Programme Manager International Cooperation

Setting the alarms in electrochemical sensor equipped toxic gas instruments

NCEHSA Conference. Carbon Monoxide Detector Regulations for Lodging Establishments (S.L )

Explosive atmospheres Part 29-2: Gas detectors Selection, installation, use and maintenance of detectors for flammable gases and oxygen

Why AC800M High Integrity is used in Burner Management System Applications?

Guide to Intrinsically Safe Portable Radios

SAFETY MANUAL. IR5000 Open Path Hydrocarbon Gas Monitoring System

SOUTH AFRICAN NATIONAL STANDARD

COPYRIGHT ULC STANDARDS

Erik Leider Project Engineer Hazardous Locations, Gas & Oil Underwriters Laboratories

What does doesn t a power supply have to comply with these days!

INTERNATIONAL STANDARD

Industrial Machinery Standards:

Record of Amendments. Version Date Amendment Section/page affected

NEW ENERGY IN THE BATTERY INFRASTRUCTURE

(1135/2016) Translation from Finnish Legally binding only in Finnish and Swedish Ministry of Economic Affairs and Employment, Finland

Nitrogen Dioxide (NO2) Single-Point Gas Detection System

A Building Manager s Guide to Maintaining Fire Code Compliance

Certificate of Compliance

EU Declaration of Conformity

HazLoc Essential Guides:

Meeting NFPA standards for

SECTION ULTRASONIC TRANSIT TIME CLAMP-ON FLOW MEASURING SYSTEM

GLOBAL ENCLOSURE STANDARDS WITHIN THE ELECTRICAL INDUSTRY

This is a preview - click here to buy the full publication. IEC Quality Assessment System for Electronic Components (IECQ System)

Florida Building Code Chapter 9 Fire Protection Systems Advanced Course

COMMISSION DELEGATED REGULATION (EU) /... of

Rosemount 4500 Hygienic Pressure Transmitter. Start

Instruction Manual Analog Vortex Mixer with Fixed Cup Head

Oxygen (O2) Single-Point Gas Detection System

BUSINESS PLAN CEN/TC 164 WATER SUPPLY EXECUTIVE SUMMARY

Test Report. Appliance EMF Testing

Two-Channel Gas Controller

Riverside County Fire Department Office of the Fire Marshal Market St., Ste. 150, Riverside, CA Ph. (951) Fax (951)

American National Standard. for Roadway and Area Lighting Equipment Solar Lighting Systems ANSI C Secretariat:

Fire protection in hazardous locations:

EMC Regulatory Requirements: What you need to know for the EU, EAEU & Australia. Dr Alex Martin

Intrinsic Safety. Intrinsically Safe Solutions. Accurate Weighing in Hazardous Areas

Electromagnetic Compatibility of Alarm Systems

Harmonizing Electrical Installation Requirements

The New EMC Directive 2004/108/EC

ISO INTERNATIONAL STANDARD. Oscillation-type density meters Part 1: Laboratory instruments

FIRE & LIFE SAFTEY STANDARD

Numerical Standards Listing

S5000 Gas Monitor. GMS5000.com

Certificate of Compliance

9/7/2010. Chapter , The McGraw-Hill Companies, Inc. AND BONDING. 2010, The McGraw-Hill Companies, Inc.

BUSINESS PLAN CEN/TC 162 PROTECTIVE CLOTHING INCLUDING HAND AND ARM PROTECTION AND LIFEJACKETS EXECUTIVE SUMMARY

Digital Gas Transmitters with Auxiliary Inputs & Control. PolyGard 2 DC6

ARTICLE 25. FUEL GAS CODE

Numerical Standards Listing

Controllers. Instruction Manual WARNING

PIP PCTPA001 Testing of Process Analyzer Systems

The European Radio Equipment Directive 2014/53/EU

Florida Building Code 2010

Transcription:

Overview of Standards for CO Detection Products Rev 1.1

1 General Overview... 3 2 Application and Installation Codes & Standards... 3 3 Product Standards... 4 4 Certified and Listed Products (Conforms to ANSI/UL Standards)... 6 5 State & City Authorities and Building Inspectors... 8 6 Performance... 9 7 The Right Choice... 10 Specifications subject to change without notice. USA 150731 Page 2 of 10

1 General Overview The commercial building industry (i.e., building owners and operators, design professionals, and institutions) is concerned about environmental safety and minimizing energy costs. When designing and choosing a carbon monoxide (CO) detection and control system for a parking structure, it is essential to evaluate established codes and standards. 2 Application and Installation Codes & Standards Various institutions, societies, organizations and government agencies (i.e., International Mechanical Code (IMC), Occupational Safety and Health Administration (OSHA), National Fire Protection Agency (NFPA), and other) have established codes and standards to limit carbon monoxide levels in parking structures. Most building codes and application standards allow demand-based ventilation in enclosed parking garages if carbon monoxide levels are monitored. This type of design can drastically reduce energy costs (i.e. operating of garage fans and heating system), increase fan belt and motor life, and reduce noise. A range of gas detection (sensors/transmitters) and control systems are available for handling the sequence of operations in parking structure applications. The actual parking structure s design will determine which type of gas detection (sensor/transmitter) and control system best fits the application. For additional information please refers to INTEC Controls CO Parking Garage Design Guidelines. The selected detectors (sensors/transmitters) and controllers must be capable of providing the control sequence of operations and alarming for the mechanical system design and building safety. Specifications subject to change without notice. USA 150731 Page 3 of 10

3 Product Standards The American National Standard Institute (ANSI) and Underwriters Laboratories (UL) have issued appropriate standards (i.e. ANSI/UL2075, ANSI/UL2017, etc.) applicable for carbon monoxide (CO) detection and control products. Only utilize CO product solutions that are tested, certified, and listed for the intended use and in compliance with the industry s standards. Electrical Safety and Performance Codes & Standards for Gas Detection and Control Systems Products Standards and technical regulations exist for gas detection, alarm and control systems in order to impose electrical safety and performance protection for the building owner & user. Many organizations and authorities participated, in a partial or full capacity, in the process of establishing codes and standards, i.e., recommending, developing, writing, establishing consensus, preparing and publishing, and enforcing protective standards. OSHA (Occupational Safety and Health Administration) OSHA establishes and enforces protective standards to save lives, prevent injuries, and protect the health of America s workers. NFPA (National Fire Protection Association) The NFPA establishes fire safety standards, including those standards for the safe operation of process. ANSI (American National Standards Institute) ANSI is a private, non-profit organization that administers, promotes, and facilitates the U.S. voluntary consensus standards and conformity assessments. ANSI is also the official U.S. representative to the International Electrotechnical Commission (IEC) and the International Organization for Standardization (ISO). The National Electric Manufacturers Association (NEMA) publishes a number of their standards. ISA (Instrument Society of America) ISA is globally recognized as a standard writing organization, developing consensus standards and protecting facilities from flammable hazards. UL (Underwriters Laboratories) UL is an independent, non-profit organization. They participate in developing standards to enhance public safety, preserve the environment, and facilitate trade. In addition, UL is a NTRL (Nationally Recognized Testing Laboratory), approved by OSHA. International CSA (Canadian Standard Association) CSA is a non-profit association serving business, industry, government and consumers in Canada and the global marketplace. They work to develop standards to enhance public safety, preserve the environment, and facilitate trade. In addition, CSA is a NTRL (Nationally Recognized Testing Laboratory), approved by OSHA. IEC (International Electrotechnical Commission) IEC is the leading global organization that prepares and publishes international standards for all electrical, electronic and related technologies. These serve as a basis for national standardization. Specifications subject to change without notice. USA 150731 Page 4 of 10

EU (European Union) The EU is a treaty-based, framework institution that defines and manages economics and political cooperation. The EU covers many issues, such as the environment, agriculture, trade, energy and transport, and mandates various standards, and directives to which manufacturers must comply. The following is a list of directives to which gas detection equipment manufacturer must comply. EC (European Conformity) The CE Mark is the official marking required by the European Community for all electric and electronic equipment that will be sold, or put into service, anywhere in the European community. It ensures that a product fulfills all essential safety and environmental requirements as defined by the EU (European Union) through the European Directives. ATEX (Atmosphere Explosive) The ATEX Directives are EU (European Union) legislation enforced since July 1, 2003. They are intended to standardize, clarify, and improve the way in which equipment used in explosive atmospheres is modified, utilized, and maintained across the EU. The purpose of the directives is to align technical and legal standards while promoting the free movement of goods throughout the EU. EMC (Electromagnetic Compatibility) The EMC Directives set essential apparatus protection requirements while dictating the electromagnetic disturbance a product may generate or be immune to. The directives are in accordance with EU standards defining the technical requirements necessary to achieve the required level of protection. The EMC Directives are applied to electrical equipment and components, domestic appliances, and industrial appliances. LVD (Low Voltage Directive) The LVD Directives apply to all electrical equipment. They are designed to operate in the voltage range of 50-1000 VAC or 75-1500 VDC. The Directives ensure that all electrical and electronic equipment placed on the market in the EU is safe. For more details and specific information, visit the websites of the appropriate organization and/or government authorities. Any carbon monoxide (CO) detection system selection done by specifying engineers, installers and building owners should include solutions that are in compliance with industry standards. Every HVAC, Security, Controls and Building professional should understand the differences between the American National Standard Institute (ANSI) and Underwriters Laboratories (UL) standards ANSI/UL 2075, ANSI/UL 2017 and ANSI/UL 2034, and be aware of the new ANSI/UL2075 requirement that became effective at the end of 2009. Specifications subject to change without notice. USA 150731 Page 5 of 10

4 Certified and Listed Products (Conforms to ANSI/UL Standards) Major Authorized NRTL CSA Canadian Standard Association (also known as CSA International) FM FM Approvals LLC (formerly Factory Mutual Research) INTERTEK / ITSNA Intertek Testing Services NA, Inc. (formerly ETL) TUV / TÜV TÜV SÜD America, Inc. (TUVAM) TÜV SÜD Product Services GmbH (TUVPSG) TÜV Rheinland of North America, Inc. (TUV) UL Underwriters Laboratories Inc. An additional six (6) approved/certified NRTL companies are available visit OSHA s website for details. Only CSA, Intertek and UL are currently certified to test to Standard ANSI/UL 2075. Nationally Recognized Testing Laboratory NRTL An organization that is approved by OSHA (Occupational Safety and Health Administration) to independently test, certify and conform electrical instrumentation and control products to the appropriate standards, and to provide product listing and labeling. Only choose CO product solutions that have the appropriate NRTL listing and label. Existing USA Standards and Certification applicable for Carbon Monoxide Detectors, Transmitters & System Controllers For Scope / Applications (key excerpts) Standards Title Applies to the following electrical products and applications: ANSI/UL 2075 Standards for Safety Gas, Vapor Detectors and Sensors/Transmitters. Commercial Buildings Commercial Buildings Multi-gas sensors/transmitters Multi-gas detectors Solely for control of ventilation or shutting off devices such as fans or control valves For operating as part of gas detection or emergency signaling systems Note: It is not appropriate to use ANSI/UL 2075 "residential type of detectors for commercial applications. Includes ANSI/UL 2034 Comments: Standard ANSI/UL 2075 incl. sensor/transmitter performance tests, and sensitivity testing to ANSI/UL 2034 NFPA in their application standard NFPA 720, 2009 edition, for installation of CO detection and warning equipment, states: Each carbon monoxide detector (senor/transmitter) shall be in compliance with ANSI/UL 2075. Also, gas and vapor detectors (sensors/ transmitters) shall meet the sensitivity tests and alarm thresholds of ANSI/UL 2034, the standard for single and multiple station carbon monoxide alarms. Specifications subject to change without notice. USA 150731 Page 6 of 10

Applies to the following electrical products and applications: ANSI/UL 2017 Standard for Safety General-Purpose Signaling Devices and Systems. Commercial Buildings Commercial Buildings Commercial Buildings Residential Dwellings Self-monitored devices or systems are intended to be self-monitoring. These devices are intended for, but not restricted to, commercial use. A product a covered by these requirements consists of a unit assembly of electrical parts having provision for the connection of power supply circuits routed through the equipment by a prescribed scheme of circuiting. Circuits extending from the products connect to separate devices by which the operating part of the product is actuated for signals, and to separate and/or integral devices by which the signals are indicated so as to form a coordinated system combination for definitive signaling services. An installation wiring diagram attached to the product, or referenced in the product marking, indicates the devices and circuits which have been determined to be capable of being used with the product in the field. Installed and used in accordance with the National Electrical Code, NFPA 70. Applies to the following electrical products: Control equipment Test and measurements Laboratory equipment Accessories Applies to electrical alarms intended for: Indoor locations of dwelling units Recreational vehicles Mobile homes Boats, enclosed spaces ANSI/UL 61010-1 IEC 61010-1 ANSI/UL 2034 Comments: Commercial CO detection and control systems for parking garages (i.e., a central control unit connected with multiple sensors/transmitters, analog or digital bus types), located across the parking space controlling ventilation and alarming, shall be certified products conforming to: - ANSI/UL 2017 for controller/central control unit - ANSI/UL 2075 for sensors/transmitter (detectors) Standards for Safety Electrical Equipment for measurement, control, and laboratory. Comments: Standard ANSI/UL61010-1 does not include sensor/transmitter performance testing. For commercial garage CO detection and control systems, the latest revised standards call for products with NRTL certification that conforms to ANSI/UL 2075 (CO sensors/transmitters) and ANSI 2017 (central control units). Many local authorities (building and safety departments), are known for strict enforcement of local codes and standards within their jurisdiction. This includes the cities of Los Angeles, San Diego, Chicago, Orlando, New York City, as well as the states of North Carolina, Oregon and Florida. The building inspectors will look for the appropriate NRTL listing on the installed products. Standard for Safety single and multiple station CO alarms. Comments: Products NRTL certified to ANSI/UL 2034 are intended for residential applications and should not be connected to a commercial central control and alarm system panel. Note: For the complete and exact definition (title, scope, etc.), please refer to the officially issued standards available through the respective organizations, i.e., OSHA, NFPA, ANSI and/or any NRTLs. Specifications subject to change without notice. USA 150731 Page 7 of 10

5 State & City Authorities and Building Inspectors State and local inspectors, who are empowered by their authority having jurisdiction (AHJ), have universally adopted the National Fire Protection Agency, standard NFPA 70, also known as the National Electrical Code (NEC). Some authorities and their inspectors are known for strict enforcement beyond the local electrical codes and may require the installed CO detectors (sensors/transmitters) and controllers to be NRTL listed. Los Angeles, San Diego, Chicago, Orlando, New York City, and as well the states of North Carolina, Oregon and Florida are some examples. The inspector or building official may red tag installed, unlabeled equipment as unfit for operation until the applicable product safety requirement is met or replaced with a NRTL listed product. Local authorities, building owners and operators have been dissatisfied in the past with many of the substandard commercial carbon monoxide (CO) detection equipment, which emphasized electrical safety only. The new ANSI/UL 2075 standard was eventually developed and adopted to address both electrical safety and product performance. The National Fire Protection Association (NFPA) in their application standard NFPA 720, 2009 edition, for installation of CO detection and warning equipment, states: Each carbon monoxide detector shall be in compliance with ANSI/UL 2075. Also, gas and vapor detectors and sensor/transmitters shall meet the sensitivity tests and alarm thresholds of ANSI/UL 2034, the standard for single and multiple station carbon monoxide alarms. Only install CO solutions which have been thoroughly performance tested and their product specifications accurately verified. Specifications subject to change without notice. USA 150731 Page 8 of 10

6 Performance Various designed and manufactured CO sensors/transmitters offer differing levels of accuracy, repeatability, detection with or without cross sensitivity to other gases, and sensor element life span. These factors will influence the performance and operating costs of the mechanical and CO detection system. The market offers mainly two types of CO gas sensing element technologies for commercial garage applications electrochemical and solid state Technology Accuracy PPM CO Life Span Features Electrochemical Type High Accuracy < +/- 1 5+ years Detects the true level of CO in ppm Reduced drift High accuracy & reduced drift means fewer calibration intervals Electrochemical Type Standard +/- 3 < 5 years Solid State / Semiconductors (MOS) Type 1 Solid State / Semiconductors (MOS) Type 2 +/- 7 to 15 7+ years Unknown 2.5 years Solid state sensors: Are cross sensitive and prone to false alarm Subject to drifts of readings at sizeable space, temperature and/or humidity change Require more frequent calibration intervals The CO central controller should have the capability to fulfill all required sequence of operation, provide selfdiagnostic with malfunction warning, intelligently identify each individual sensor/transmitter s detection value and local and remote alarms, and sensor element s End-of-Life (EOL) fail-safety alarm. Review the product data sheet s specifications and select the solution that will secure an economical installation, provide safety and performance to fit the mechanical system design, and lower calibration intervals. Specifications subject to change without notice. USA 150731 Page 9 of 10

7 The Right Choice The analog or digital multi-point bus CO detection and control systems for commercial parking structures should provide: Sensor/transmitter: NRTL Performance Tested & Certified, conforming to STD ANSI/UL 2075 Central Controller: NRTL Tested & Certified, conforming to STD ANSI/UL 2017 Specifications subject to change without notice. USA 150731 Page 10 of 10