G Trap FliQ FPLC Columns

Similar documents
Columns XK 16, XK 26, XK 50 Adaptors AK 16, AK 26, AK 50 INSTRUCTIONS

Methods of solid phase extraction. Methods of solid phase extraction

A HEATER KIT With Diesel Engine Connection Fittings

wash system V1.3 Important: Up to slides on one injection. Note: Getting need to turn it samples the next day. and put the slides in foil, put it

until filters are dry. Once dry, place the filters shiny side up in petrislides. The petrislide do NOT need to be acid washed.

SEC-MALS Noise Assessment and Cleaning Guide

Multi-Mode Electrode pro

Thermo Scientific KingFisher Total RNA Kit Instruction Manual Rev. 1.2

Aspirator with trap flask FTA-1

HEGA-Medical Product list V7.0

User Guide. ROSS Process Combination ph Electrode

Solid Phase Extraction using the 96-well Format ISOLUTE -96 Fixed Well Plates and ISOLUTE Array 96-well Plates

GB National food safety standard Determination of benzoic and sorbic acid in milk and milk products

FLECK 5600 WATER SOFTENER INSTALLATION

Assembly of a Microbial Fuel Cell

Eldex Column Heater. Operator s Manual

Ion OneTouch Template Kit Publication Part Number Revision E Date 31 October 2011

ACQUITY UPLC H-Class Column Compartments Operator s Overview and Maintenance Information

ACME DIAGNOSTICS STANDARD OPERATING PROCEDURE

GE Healthcare. Mixer M-925. Instructions

Code (300ml)

FTA-1 Aspirator with trap flask

Nafion Dryer. Installation Manual QUI Version 1.4. October 2013

DIRT! APES Laboratory Activity

Spare parts list. Hydraulic compactor RC

Liquid Samplers. Powders. Tel: +44 (0)

Installation Manual. Humidifier for CIA Advantage. Version 1.1. March 2013

Rain&Drain. Assembly and Maintenance. Instructions. Contents: Kit box. Instructions. Oxy tube inc valve. Oxy pump. Measuring beaker.

ACQUITY UPLC HT Column Heater Instructions

Retractable ph/orp Sensor

Agilent Vac Elut SPS 24 Manifold User Guide

RESOLUTION OIV-OENO MONOGRAPH ON TANNINS UPDATE OF THE METHOD FOR DETERMINATION OF POLYPHENOLS

NEOTeCHA Reactor Sampling Type PV

Chargebuster Ion Gun Installation, Operation and Maintenance

Microwave Digestion. Microwave Digestion

Corning Storage Bottles Selection and Use Guide

DISPOSABLE CONTAINERS FOR SUCTION APPLICATIONS FLOVAC CONTAINER WITH MECHANICAL VALVE

Thank you for choosing the Motif Duo Double Electric Breast Pump. Motif Duo Operation Manual

Product Guide for Ludger Clean Post-endoglycosidase and Post-exoglycosidase Clean-up Plate

SimpleVIS Viscometer Reference Guide P

Operator s Manual. The Bullet Blender 50 BB50-AU, BB50-DX. Contents. Congratulations!

STANDARD OPERATING PROCEDURES

Operating Instructions

Compresstome VF-300-0Z User Manual

82 Constant Voltage SPECIFICATIONS. 316L SS Pressure Sensor 19mm Diameter Package 0-100mV Output Absolute and Gage Temperature Compensated

Rain Forest Quick Guide

Model # VWK-2 INSTRUCTION MANUAL

Drinking Water Purification Systems

Megaruptor. DNA Shearing System USER MANUAL. Megaruptor. Version 2. Cat. No. B

User Guide. Double Junction Reference Electrode

INSTALLATION INSTRUCTIONS GPM SERIES LOOP PUMP MODULES

AUC Cell Washer. User Manual

analytical laboratory clear amber bottles clear bottles

Ultrasonic Aroma Diffuser AD-SD1-CE

Installation Instruction. Puritan Bennett. Wall Air Water Trap For 800 Series Ventilator Basic Cart. Pla

DIRECTIONS FOR USE. Keeping you insafehands to avoid needlestick injuries. see for demo video

PROCEDURES FOR VACUUM MODLING FILTER SAMPLES Chan CHECKLIST OF OPERATION. 1. Checklist for preparation of filter media (glass fiber only)

RENZ FOR QUALITY PRODUCT CATALOGUE.

OWNER S MANUAL CAVN SERIES SELF CONTAINED RETRACTABLE NOZZLE VACUUM SEALER WITH GAS PURGE

Thermo Scientific KingFisher Pure RNA Tissue Kit Revision 1.0

Catch Cans. What makes the RX performance the most effective oil separating catchcan on the market?

SINGLE SPEED SYRINGE PUMP

Notice d installation et d utilisation Français. Instructions for installation and use English. Manual de instalación y de uso Español

OWNER S MANUAL AVN SERIES RETRACTABLE NOZZLE VACUUM SEALER WITH GAS PURGE

Corning Storage Bottles Selection and Use Guide

HP-500 Plus, XP-1500 Plus & OMNI

Criterion Dodeca Cell. Instruction Manual. Catalog Number

Vacuum Equipment. Manifolds. Traps. Pumps. Adapters. Easy to assemble Ace-Safe connector versions. O-Ring connections. Added safety and versatility

Technical Specifications & Pricing

volumetric laboratory Calibrated to deliver (Ex) and the tolerances are according to DIN/ISO Class AS standards.

NEW Restek Electronic Leak Detector

Ion PGM Hi Q View Sequencing Kit

Mitocell: Instructions for Use

FL-1000 FLEC Air Control

RapidTrace + Automated SPE Workstation. Instruments. Accessories Racks Vial Adapters Test Tubes O-Rings Miscellaneous

Operating Manual for. Ultrawash Plus. Absorbance. Plate Washing. Luminescence. Automated Processing. Software

ElEctronIc 2 DIal tap timer co1701 InstructIon Manual

PrimePour TM Operation Manual

MST, INC. MODEL 2002 CARBON MONOXIDE MONITOR OWNER S MANUAL

Parasitic Cysts - Cryptosporidium and Giardia, Chemicals, Heavy Metals, Dissolved Salts, Offensive Tastes and Odours, Sediment, Dirt,

PARTS GLOSSARY Comprehensive Ozone Package

918 Clock Gauge Installation, Operation, and Maintenance Instructions

HANDS-ON MODULE 5. CLEANING FLOW-i V3.0

ALLERGEN MIXING ASSISTANT

Incubating Shaker with Cooling

WINDSHIELD REPAIR MANUAL SUPER CINCH

PARTS GLOSSARY Basic Insufflation Pro Package

AUTOTROL 363TC AUTOMATIC FILTER VALVE SERVICE MANUAL

General System Layout Sketch

Thermo Scientific KingFisher Viral NA Kit Instruction Manual Rev. 1.2

INSTALLATION INSTRUCTIONS

Advancing the power of SPE. Intelligent Automated Solid Phase Extraction. SmartPrep Brochure

MyGel Mini. Operating Manual Version 1.0. a division of. Electrophoresis System

PROTOCOL FOR FREE LIPID SOP

Experiment 4: Purification of Liquids by Distillation

Thermo Scientific KingFisher Pure RNA Plant Kit Revision 1.0

Dual Adjustable Mega-Gel System

Operator s Manual. The FREEDOM ROCKER. Contents. Congratulations!

ultra quiet fan USER MANUAL INSTALLATION OPERATION MAINTENANCE

Operating Manual for Profident / Profident PLUS

Transcription:

G-Biosciences 1-800-628-7730 1-314-991-6034 technical@gbiosciences.com A Geno Technology, Inc. (USA) brand name G Trap FliQ FPLC Columns (Cat. # 786 1292, 786 1293, 786 1294, 786 1295) think proteins! think G-Biosciences www.gbiosciences.com

INTRODUCTION... 3 ITEM(S) SUPPLIED... 3 STORAGE CONDITIONS... 3 ADDITIONAL ITEMS REQUIRED... 4 SPECIFICATIONS... 4 G TRAP FLIQ FPLC COLUMN PACKING... 4 PACKING OF G TRAP 1ML FLIQ FPLC COLUMN... 4 PACKING OF G TRAP FLIQ FPLC 5ML, 10 ML AND 20 ML COLUMNS... 5 RELATED PRODUCTS... 6 Page 2 of 8

INTRODUCTION G Biosciences present several empty low pressure chromatography columns. The columns and its parts are made of polypropylene which is chemically resistant to most of the commonly used reagents for chromatography. The end adaptors supplied with the column contain 10 32 UNF connections which are compatible with all commonly used chromatography instruments. The maximum operating pressure for G Trap 1ml FliQ FPLC Column is 5 bar and 3 bar for 5 ml, 10 ml and 20 ml G Trap FliQ FPLC Columns. ITEM(S) SUPPLIED Cat. # Description Size 786 1292 G Trap 1ml FliQ FPLC Column 1 Column 786 1293 G Trap 5ml FliQ FPLC Column 1 Column 786 1294 G Trap 10ml FliQ FPLC Column 1 Column 786 1295 G Trap 20ml FliQ FPLC Column 1 Column 786 1296 10.32 packing connector (1pc) 1 G Trap 1ml FliQ FPLC Column Parts: Column Part for 1ml Column Column Body Description Internal diameter of 6.2 mm with volumetric marks at 0.1 ml intervals. Contains a locking mechanism at both ends. Quantity supplied: 1 End Adaptors Contains a 10 32 UNF female thread at one end and an O ring and frit disc at the other end. This results in a minimum void volume. Quantity supplied: 2 Stop Plugs 10 32 UNF male thread. Used to create a finger tight seal for a packed column. Quantity supplied: 2 STORAGE CONDITIONS Columns are shipped under ambient temperature along with its connectors. Store at RT when not packed with resin. Store at 4 C when packed with resin. Page 3 of 8

ADDITIONAL ITEMS REQUIRED 10.32 packing connector (1pc) (Cat. # 786 1296). It s a leur/thread connector used to connect syringes to 6.2 mm, 11 mm and 16 mm i.d. columns. Resin slurry SPECIFICATIONS Maximum pressure for G Trap 1ml FliQ FPLC Column is 5 bar (70 psi) Maximum pressure for 5 ml, 10 ml and 20 ml G Trap FliQ FPLC Columns is 3 bar (42 psi) ph stability: 2 14 Recommended flow rate: 0.5 2 ml/ min Chemical compatibility: Resistant to all common aqueous buffers, denaturants including 8M urea, 6 M guanidine hydrochloride and chaotropic salts G Trap 1ml FliQ FPLC Column housing: Medical grade polypropylene G Trap FliQ FPLC 5 ml, 10 ml, 20 ml Columns housing: Acrylic Bed dimensions for G Trap 1ml FliQ FPLC Column: 33 x 6.2 mm Bed dimensions for G Trap 5ml FliQ FPLC Column: 52 x 11 mm Bed dimensions for G Trap 10 ml FliQ FPLC Column: 104 x 11 mm Bed dimensions for G Trap 20 ml FliQ FPLC Column: 100 x 16 mm End adaptors: polypropylene; 10 32 UNF female thread (1/16 ) Stop plug: 10 32UNF male thread (1/16 ) G TRAP FLIQ FPLC COLUMN PACKING Packing of G Trap 1ml FliQ FPLC Column 1. Insert the End adaptor into one end of the column body. NOTE: Make sure that the catch of the tab of End Adaptor is aligned with open grove on top of the column body and push the adaptor till its completely engages with the shoulder of the column. 2. Screw 10.32 packing connector (not supplied with column) to the End Adaptor. 3. Use a syringe pre filled with 1 2 ml of deionized (DI) water to fill the column to a level of 0.2 0.3 ml. 4. Fill the column with 50% resin slurry and with a syringe suck the resin bed down. NOTE: Take care not to dry resin when packing the column 5. Repeat step4 until the packed volume is reached. NOTE: Desired packed volume depends upon the type of resin used. For agarose based resin, packed volume should be in range 1.2 1.4 ml. 6. Keep the syringe in place and pipette DI water to fully fill the column. 7. Insert the top End Adaptor down carefully such that air bubbles are not trapped. Push it down gently till the liquid reaches the thread. 8. Screw a Stop Plug finger tight to seal the top of the column. Page 4 of 8

9. Push the top End Adaptor down till it is fully locked. 10. Remove the 10.32 packing connector (1pc) and the syringe. Screw the bottom End Adaptor finger tight with another Stop Plug provided with the column. Packing of G Trap FliQ FPLC 5ml, 10 ml and 20 ml Columns 1. Use storage buffer to moderately dampen the double O rings in each End Adaptor. 2. Insert the End Adaptor into one end of the Column Body carefully, avoiding the direct contact of mesh with the column wall. Push the adaptor till its fully engaged in the column body. 3. Screw 10.32 packing connector (not supplied with column) to the End Adaptor. 4. Keep the open side of column upward and vertical and hold the column with stand. 5. Fill syringe wit 2 5ml of DI water or storage buffer and fill the column to level of 1 2 ml. NOTE: Use 20 ml syringe for 5 ml and 10 ml columns, and 50 ml syringe for 20 ml column. 6. Shake the resin bottle to bring resin in suspension and pipette 50 % slurry into the column. With the syringe suck the bed down without drying the resin. NOTE: The bed permeability decreases with increase in bed height. NOTE: 1 cm column is equal to approximately 1 ml bed volume for 5 ml and 10 ml columns and 2 ml bed volume for 20 ml columns. 7. Repeat the step 6 until the packed volume reaches the target level. NOTE: During packing empty the syringe if it is full of the storage buffer or water. NOTE: Desired packed volume depends upon the type of resin used. For agarose based resin, packed volume should be 6 ml for 5 ml column, 12 ml for 10 ml column and 24 ml for 20 ml column. 8. Keep the syringe in place and make sure there is at least 5 ml additional capacity in the syringe. 9. Pipette in water or storage buffer to the top of column. Insert the top End Adaptor down carefully such that air bubbles are not trapped. Push it down slowly till two O rings are inserted into the column body. 10. Screw a Stop Plug finger tight to seal the top of the column. 11. Push the top End Adaptor down till it is fully locked. 11. Remove the 10.32 packing connector (1pc) and the syringe. Screw the bottom End Adaptor finger tight with another Stop Plug provided with the column. 12. Pump through 10CVs of equilibration buffer at a flow rate at least 30% higher than operational flow rate. The column is ready to use or to storage at 4 C. NOTE: Ensure that the back pressure always remain under 3 bar Page 5 of 8

RELATED PRODUCTS Download our Sample Preparation and Protein Purification Handbooks. http://info2.gbiosciences.com/complete protein purification handbook For other related products, visit our website at www.gbiosciences.com or contact us. Last saved: 5/23/2017 CMH Page 6 of 8

This page is intentionally left blank Page 7 of 8

www.gbiosciences.com Page 8 of 8