TENDER NO: MR 92/2017 SUPPLY OF HIGH VOLTAGE PROXIMITY DETECTORS

Similar documents
Fiji Electricity Authority Transmission Unit 2 Marlow Street, Suva

Tender Document. MR 193/ Design, Supply & Commission New Control Panel for Ruston 16RK270 Generator

Eligibility Criteria for Participation [Qualification Requirement (QR)]

SPECIFICATIONS FOR TENDER # SUPPLY OF A FIRE ALARM SYSTEMS SERVICE AGREEMENT FOR WESTERN HEALTH

* To be remitted only through DD/Banker Cheque, in favour of Bank of Baroda, payable at Bhopal.

SPECIFICATIONS FOR TENDER # SUPPLY OF DUCTLESS MINI-SPLIT AIR CONDITIONING SYSTEMS FOR WESTERN HEALTH

BANK OF BARODA BIHAR REGIONAL OFFICE, 4 TH FLOOR, ANAND VIHAR, West Boring Canal Road, Patna TENDER NOTICE

BANK OF BARODA ZONAL OFFICE, MP & CG ZONE BHOPAL TENDER NOTICE

NOTICE TO CONTRACTORS

HIGH VOLTAGE A.C. PROXIMITY DETECTOR HI-PROX

CALL FOR TENDER - MUNICIPALITY OF THE DISTRICT OF CLARE LITTLE BROOK, N.S.

Date of Start and downloading the tender 12 sep 2018

INTER - UNIVERSITY ACCELERATOR CENTRE (An Autonomous Centre of UGC) Aruna Asaf Ali Marg, New Delhi

NOTICE INVITING TENDER

INDUSTRIAL EXTENSION BUREAU

This is a preview - click here to buy the full publication INTERNATIONAL ELECTROTECHNICAL COMMISSION

Australian/New Zealand Standard

Due to large sum and BG processing time it is requested to offer 15 Working days instead of 7 working days.

Detail Notice Inviting Expression of Interest for Survey & Fire Safety Audit

275HVD NON-CONTACT, HIGH VOLTAGE DETECTOR DETECTOR DE ALTA TENSIÓN SIN CONTACTO

SMALL WORKS PROJECT REQUEST FOR SEALED BIDS

.4 Do complete installation in accordance with latest Electrical Bulletins of the local inspection authority.

The following are the terms and conditions for the firms for submission of bids:

SAFETY PERSONAL AC VOLTAGE (50 or 60Hz) PROXIMITY DETECTOR

Linear Heat Detection Engineering Specifications

ACMA mandated EMC standards

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

Australian Standard. Electroacoustics Sound calibrators AS IEC This is a free 7 page sample. Access the full version online.


(1135/2016) Translation from Finnish Legally binding only in Finnish and Swedish Ministry of Economic Affairs and Employment, Finland

NB/ 0695/MFFS/P 17A Feb 18 REQUEST FOR INFORMATION (RFI) FOR SUPPLY AND INSTALLATION OF MAGAZINE FIRE FIGHTING SYSTEM

SENTINEL A - Fault Passage Indicator

BANK OF BARODA BARODA CORPORATE CENTRE MUMBAI

STAR HOUSE BANK OF INDIA NATIONAL BANKING GROUP NORTH-I H-2 CONNAUGHT CIRCUS Middle/Outer Circle, Phone No

Sidney, Ohio 1204 FORMAL ISSUANCE OF CERTIFICATE OF SUBSTANTIAL COMPLETION... ON OR BEFORE JULY 30, 2015.

INTERNATIONAL STANDARD

INVITATION TO BID. Allendale Elementary School 3670 Penniman Avenue, Oakland, CA 94619

Department of Biochemistry University of Lucknow Lucknow

SENTINEL D - Fault Passage Monitoring

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

NATIONAL BANKING GROUP WEST-1

INVITATION TO BID SUPPLY OF VARIOUS PORTABLE FIRE EXTINGUISHERS

Relationship beyond banking

Majis Industrial Services SAOC TENDER NO. MISCP/09/2014

No. BU/55/Estate/2000/NIOH/Pt.-VI/ 533(3) 01 st May, 2015 NOTICE INVITING TENDER

On Electromagnetic Compatibility

Medical devices and electromagnetic compatibility. Addressing the requirements of IEC , 4 th Edition

LIFE INSURANCE CORPORATION OF INDIA DIVISIONAL OFFICE 16/275, CIVIL LINES, KANPUR

CORRIGENDUM NO: 2 TO REQUEST FOR QUOTATION CRFQ NO E-Tender Ref. No: 9093

Recent Topics in IEC TC 62 (Electrical Equipment in Medical Practice) and its Subcommittees

INTERNATIONAL STANDARD

RULEBOOK ON ELECTROMAGNETIC COMPATIBILITY

ODISHA POWER TRANSMISSION CORPORATION LIMITED OFFICE OF THE GENERAL MANAGER EHT (O&M) CIRCLE, BIDYUTPURI COLONY, BERHAMPUR

Procedure for the Approval of New Fire Detection and Alarm Technologies

SAINT JAMES HOSPITAL GROUP PURCHASING DEPARTMENT

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 1

Audible warning devices for external alarm

SPECIFICATION FOR GAPLESS METAL OXIDE DISTRIBUTION TYPE SURGE ARRESTERS WITH POLYMERIC HOUSING

IEC/TC IEC/TC44 IEC/TC44. Amd.1DC:201. Ed.3CD:2011. Ed.2.1:2008. Amd.1CDV ED.1: 一連番号 Ed.

FIRE ALARM SYSTEM 1.1 GENERAL REQUIREMENTS

AS/NZS IEC :2016

MUNICIPALITY OF GREENSTONE BOX 70, 1800 Main Street Geraldton, Ontario P0T 1M0 Telephone Facsimile

Test procedure/ method name. method identification. Testing of industrial and explosion isolation valves and tank lining

C 271/32 Official Journal of the European Union

Table of Contents FOREWORD... 3 INTRODUCTION SCOPE NORMATIVE REFERENCES DEFINITIONS AND ABBREVIATIONS REQUIREMENTS...

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

Sec False alarms.

TAG MR VOLTAGE DETECTORS AND ACCESSORIES. Instruction & Operation Manual

Fort Rouge Leisure Centre Section HVAC Upgrades Phase 2 Page 1 of 5 Bid Opportunity No March 2013 FIRE ALARM SYSTEMS

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

This is a preview - click here to buy the full publication

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

EMC Regulatory Requirements: What you need to know for the EU, EAEU & Australia. Dr Alex Martin

Tender document for Supply/ Installation of New Fire extinguishers & Refilling TENDER NOTICE

Rules for Classification and Construction Additional Rules and Guidelines

This is a preview - click here to buy the full publication. High-voltage switchgear and controlgear

Can You Hear Me Now?

TENDER NOTICE FOR DESIGNING, SUPPLY, INSTALLATION, TESTING, COMISSIONING AND MAINTENANCE OF FIRE ALARM SYSTEM AT APROX.

Smoke and heat control systems - Part 10: Power supplies EN Classification according to operational and environmental class

E-20 COMPARTMENT FLOODING WATER LEVEL DETECTORS (INCLUDING SENSORS)

Summer Works Scheme 2010

Bharat Heavy Electricals Limited (High Pressure Boiler Plant) Tiruchirapalli , TAMIL NADU, INDIA MATERIALS MANAGEMENT / CAPITAL EQUIPMENT

Specification of (COC) Automatic Open Cup Flash Point Tester with accessories

STATEMENT OF WORK ELECTRICAL REPAIR / MAINTENANCE BUILDING PROJECT FDC RACCOON CREEK STATE PARK (BEAVER COUNTY)

Can You Hear Me Now?

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

PD240 NEW GENERATION WIDE SEARCH AREA HAND HELD METAL DETECTION SET FEATURES

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

TENDER FOR EMPANELMENT OF VENDORS FOR REFILLING AND SUPPLY OF NEW FIRE EXTINGUISHERS FOR BRANCHES AND OFFICES IN ZONE UNDER

Replacement of Fire Pump and Generator Upgrade, H Building, Sexton Campus

SECTION AUTOMATIC TRANSFER SWITCHES

Federal Law of the Russian Federation of December 27, 2009 N 347-FZ "Technical regulation on safety of low-voltage equipment" Part I

BID FORM CITY OF BEVERLY HILLS. The undersigned, having carefully examined the site conditions and the Contract Documents for

Township of Maplewood

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

Driveway Alarm INSTALLATION MANUAL.

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2017

OFFICE OF THE PRINCIPAL GOVERNMENT ENGINEERING COLLEGE JAGDALPUR (C.G.)494005

RFP # FIRE STATION ALERTING SYSTEM FOR THE CITY OF BLOOMINGTON FIRE DEPARTMENT

Transcription:

TENDER NO: MR 92/2017 SUPPLY OF HIGH VOLTAGE PROXIMITY DETECTORS

Supply of High Voltage Proximity Detectors for Transmission Unit TENDER DOCUMENT AND SPECIFICATIONS The Fiji Electricity Authority invites sealed tenders from reputable companies with the relevant experience, for the Supply of High Voltage Proximity Detectors. The equipment would be used for compaction works in carrying out detection of the presence of high voltages on overhead lines, switchgears, underground cables and other high voltage equipment. TECHNICAL SPECIFICATIONS FOR HIGH VOLTAGE PROXIMITY DETECTOR 1) Standards Applicable for this Tender The High Voltage Proximity Detector shall be designed, manufactured and tested in accordance with the requirements for the following Conformity Directives. AS 61010.1: 2003 Safety requirements for electrical equipment for measurement, control and laboratory use EN 55011: 2009 Industrial, scientific and medical equipment Radio-frequency disturbance characteristics Limits and methods of measurement AS/NZS 61000.4.2: 2002 Testing and measurement techniques Electrostatic discharge immunity test AS/NZS 61000.4.3: 1999 Electromagnetic compatibility (EMC) - Testing and measurement techniques - Radiated radiofrequency electromagnetic field immunity test Note: Bidders shall demonstrate/submit proof of ownership and possession of aforementioned directives. 2) Manufacturer s Qualification The manufacturer shall be ISO 9001-2000 and ISO 14001-2004 certified and shall maintain a development and engineering department to provide a technical after sales service and information related to the High Voltage Proximity Detector. Manufacturer shall have sufficient supply and manufacturing experience of High Voltage Proximity Detector for at least ten (10) years for the required work specifications. As proof, the manufacturer shall submit a supply-list indicating type of High Voltage Proximity Detector, quantity supplied, name of client and the year of delivery. Certificates from customers with satisfactory usage shall be provided with the supply record. High Voltage Proximity Detector shall be considered, for which a minimum 5 years manufacturing and successful service experience is available, without change of basic design and material. 1 P a g e

The qualified manufacturer shall have designed, manufactured, tested and supplied at least 3,000 units of similar High Voltage Proximity Detectors for the same work specification 3) Design and Material Requirements a. The product must work for different voltage ranges (Minimum: 240V; Maximum: 275kV) b. The tester shall have a sensor that does not require physical contact with electrical conductors. It should be able to work from a distance of at least 5 centimeters. c. The device shall work in operating temperatures ranging from -15 Degrees Celsius - d. It shall have bright LEDs visual indication e. It shall also have a sound indication detecting the presence of voltage f. Shall have an easy to prove method g. A provision for self test selection shall be provided h. Should be able to work with Type C Lithium batteries i. The device shall have a High impact nylon casing j. It shall be compatible with Link Sticks and mountable using universal attachment coupling. k. The High Voltage Proximity Detector shall be Light weight, robust and compact l. Should be suitable or both indoor and outdoor use m. The High Voltage Proximity Detector should easily detect low voltage on any systems in the range of 240VAC to 275kVAC n. The detector shall have dual annunciation modes i.e. both Audio and Visual. The Audio annunciation should be a distinct beep audible from a distance of 15m and the visual annunciation shall be bright LED lights. o. The device shall be accompanied by a Rugged Casing that makes it robust while carrying it to various sites. p. The supplier shall also provide a Testing and Calibration certificate of each unit supplied to FEA. 4) Experience Evaluation For evaluation of manufacturer s qualifications, the manufacturer must submit a reference list showing supply experience for supply of High Voltage Proximity Detector. In addition, if any in-service failures due to the quality of High Voltage Proximity Detectors have been experienced, the manufacturer should submit the information on the failures including the cause of the failures and the counter consequences taken. 5) Prices and Quantity Required Prices shall be quoted in Fijian Dollar Currency, inclusive of all taxes, customs, clearance charges, and duties payable in Fiji and for delivery to FEA s Navutu Depot in Lautoka. SCHEDULE OF QUANTITIES AND BIDDER s PRICES ANTICIPATED QUANTITY REQUIRED 20 2 P a g e

BIDDER s UNIT PRICE FJD $ (VIP) (Including all applicable taxes, customs clearance charges and duties) BIDDER s LUMP SUM PRICE FJD $ (VIP) (Including all applicable taxes, customs clearance charges and duties) Bidders to utilize the above table to submit prices. Prices shall be valid for at least 90 calendar days, from the closing date of this tender. 6) Packaging The High Voltage Proximity Detector shall be securely and effectively packaged in prefabricated packaging that has sufficient strength for normal handling. 7) Duration of Production and Delivery The FEA requires the delivery of High Voltage Proximity Detectors by the 1 st April 2017. Bidders shall clearly indicate the duration of production and shipping (if applicable). 8) Payment Terms FEA s standard 30 days payment policy upon delivery of goods and services applies. Bidder s to explicitly note all exceptions and/or reservations to the same if any. 9) Warranty The supplier shall provide a warranty of at least one year for the High Voltage Proximity Detectors supplied to FEA. 3 P a g e

Tender Submission - Instruction to bidders It is mandatory for Bidders to upload a copy of their bid in the TENDER LINK Electronic Tender Box no later than 4:00pm, on Wednesday 17 th May, 2017. To register your interest and tender a response, view 'Current Tenders' at: https://www.tenderlink.com/fea For further information contact The Secretary Tender Committee, by e-mail TDelairewa@fea.com.fj In additional, hard copies of the tender, one original and one copy must be deposited in the tender box located at the FEA Head Office, 2 Marlow Street, Suva, Fiji no later than 4:00pm, on Wednesday 17 th May, 2017- Addressed as Tender MR 92/2017 Supply of High Voltage Proximity Detectors The Secretary Tender Committee Fiji Electricity Authority Head Office Suva Fiji Hard copies of the Tender bid will also be accepted after the closing date and time provided a soft copy is uploaded in the e-tender Box and it is dispatched before the closing date and time. Tenders received after 4:00pm on the closing date of Wednesday 17 th May, 2017. will not be considered. Lowest bid will not necessarily be accepted as successful bid. It is the responsibility of the bidder to pay courier chargers and all other cost associated with the delivery of the hard copy of the Tender submission including any Duties/Taxes. Hard copies of the Tender submission via Post Box will not be considered. 4 P a g e