AND INSTALLATION MANUAL

Similar documents
OilSET Installation and Operating Instructions. Oil Separator Alarm Device with SET/DM3AL sensor

OilSET Installation and Operating Instructions. Oil Separator Alarm Device

SET-2000 Oil/Sludge 12 VDC

OilSET-1000 (12 VDC)

SET Installation and Operating Instructions. Level switch for one sensor

SET-2000 Hi Level/Oil

SET-2000 Oil/Sludge. Alarm Device for Oil Separators. Installation and Operating Instructions

Labkotec automatic warning devices for separators protecting the environment

SolarSET GSM SolarSET GSM with a Beacon

Labkotec SET. Labkotec separator alarm system protecting our environment. Measure your success

LevelSET S GSM Functionalities Instructions for Commissioning and Use

Technical Data. Dimensions

Inductive slot sensor

Technical Data. General specifications Switching element function Rated operating distance s n 5 mm

Technical Data. General specifications Switching element function Rated operating distance s n 5 mm

Technical Data. Dimensions

Technical Data. General specifications Switching element function Rated operating distance s n 8 mm

PEPPERL+FUCHS GmbH

EU DECLARATION OF CONFORMITY

SITRANS T. SITRANS T Explosion protected temperature sensor. General information. Marking of the degree of protection. Range of uses.

Installationsmanual GWSL1100/2100, GWML3100

Technical Data. General specifications Switching element function Rated operating distance s n 4 mm

Operating Instructions Edition 02/2007

OPTIBAR P 1010/2010 C Supplementary instructions

Technical Data. General specifications. Rated operating distance s n 5 mm

Operating Instructions

OOH740-A9-Ex Multi-sensor fire detector

OOH740-A9-Ex Multisensor fire detector

4) Intrinsic Safety Certification

Labkotec Measurement Technology

VERSAFLOW VORTEX Supplementary instructions

FDOOT241-A9-Ex Multisensor fire detector

Additional Operating Instructions SITRANS F. Vortex flowmeters. SITRANS FX330 Ex-i.

Labkotec Level Instruments Protecting our environment

Technical Data. General specifications Switching element function DC Dual NC Rated operating distance s n 3 mm

Supplementary Installation and Operating Instructions. Category II2G

INSTRUCTION MANUAL (ATEX)

RADAR LEVEL GAUGE SPECIAL SAFETY INSTRUCTION

Tank Gauging System Special Safety Instruction

INSTRUCTION MANUAL IS-mB1 Minialite Intrinsically Safe Round LED Beacon

OMC Ex interface unit. Manual. Version 1.2 August Author: Observator Instruments

Local Control Panels for VG9000H LCP9H Series. Installation, Maintenance and Operating Instructions

Alarm system For oil-water separator

OSA 3. Level alarm for oil separator. Afriso Ema AB. Kilvägen 2 SE Arlöv Sweden T +46-(0) F +46-(0)

ATEX Installation Instructions for Micro Motion F-Series Sensors with Certificate DMT 01 ATEX E 158 X

OPTIWAVE X500 Supplementary Instructions

Local Control Panels for VG9000H LCP9H Series. Installation, Maintenance and Operating Instructions

Safety instructions VEGADIF DF65.GX*****H/Z/P/F***** IECEx BVS

Additional Operating Instructions SITRANS F. Vortex flowmeters. SITRANS FX330 Ex-nA.

Ex Long & Short stroke LPI POSITION TRANSMITTER MKII For linear position measurement in compressors

DB5 Intrinsically Safe Sounder Type DB-5

Pressure sensors. Ex ia I / IIC T6 acc. to ATEX. Features. Description. Measuring ranges. Applications

INSTRUCTION MANUAL. SIL 3 - SIL 2 IIB Group Power Supply for Hazardous Area Equipment DIN-Rail Model PSD1001C PSD1001C

Annubar Flowmeter Series

Operating Manual MS220DA

Technical Data. Dimensions

Operating Instructions

PROZESSAUTOMATION. Manual SEGMENT PROTECTOR R-SP-!12. Zone 1 Zone 2 / Div 2 FNICO

SEPARIX. Technical Documentation. SEPARIX-C/-T and SEPARIX-Control CT. Edition: Version: 5 Art. no.:

Earth-Rite II PLUS Static Earthing System

Snifter ATEX22 VERSION. User Manual. Distributor

INSTRUCTION MANUAL (ATEX/IECEx/SIL2) BExBG05D-SIL Flameproof Xenon SIL 2 Beacons For use in Flammable Gas and Dust Atmospheres

Additional Operating Instructions SITRANS F. Vortex flowmeters. SITRANS FX330 Ex-d.

Labkotec Ice Detector

MANUAL Oil Level Sensor

Installation and Operating Instruction

Immersion heaters for ATEX/IECEx hazardous areas or in non-atex version

MANUAL Overflow sensor NVF-104/34-PF

Circulation heaters for ATEX/IECEx hazardous areas or in non-atex version

IS (Intrinsic safety) - Ex (Epsilon x) ATEX CENELEC

PROFIBUS-PA Display RID 261 PROFIBUS-PA

E2S Datasheet v10a. The IS-mA1 is suitable for all intrinsically safe signalling applications including fire, security and process control.

Documentation. Explosion-Protection. for Smoke Detection Panels SDS-4, SDS-8, SDS-12 and Extension Panels SDS-E8, SDS-E12, SDS-E16, SDS-EC16

Operating Manual MS220KA and MSR220KA

OPTIBAR DP 7060 Supplementary Instructions

IECEx Certificate of Conformity

Translation of the assembly instructions with operating instructions and technical appendix

Duct heaters for ATEX/IECEx hazardous areas or in non-atex version

Sensor module. Operating instructions. Sensor module, Type 17-51P2-... Document No P2-7D0001 Version: 17 May 2011/Rev. 0

Intrinsically Safe, NEMA 4, Type 4X, IP67 Loop-Powered Meter

DSF xx15.xx xhv Ex-Atex Ex-Atex Certified Two wire Hall Effect Speed Sensor

INTRINSICALLY SAFE S314X AND S315X

Certificate of Compliance

for CE 134 CCSAUS certificate Meggitt SA Route de Moncor 4 PO Box 1616 CH Fribourg Switzerland Title page EN

ExDetector HC-100. Data Sheet. Gas Measuring and Alarm Systems

Mobrey MSP900SH Level and MSP900FH Flow Ultrasonic Transmitters

SBEx-4 BISTATE SEPARATOR 1, 2, 3 or 4 channels in rail housing (TS35, 22,5mm width)

INSTRUCTION MANUAL (ATEX / IECEx)

INSTRUCTION MANUAL. SIL 2 Load Cell/Strain Gauge Bridge Isolating Converter DIN-Rail Power Bus and Termination Board Model D5264S D5264S

Certificate of Compliance

Rosemount 3100 Series Ultrasonic Level Transmitters

Operating Instructions

HYTEK ATEX APPROVED BUND ALARM

Certificate of Compliance

PESO. Temperature sensors with cables Thermocouples and RTD temperature probes ATEX I, e, t For use in areas with an explosion hazard

FDCL221-Ex Line adapter (Ex)

BA338C Intrinsically safe Externally powered pulse input panel mounting rate totaliser issue 13

Indoor/outdoor resistance thermometer Model TR60

Declaration of conformity

Integrated Solutions Low Voltage Systems

Transcription:

Labkotec Oy Myllyhaantie 6 FI-33960 PIRKKALA FINLAND Tel. +358 29 006 260 Fax +358 29 006 1260 Internet: www.labkotec.fi 10.10.2013 SET/DM3AL Level sensor OPERATION AND INSTALLATION MANUAL 1(5)

SYMBOLS 1. YLEISTÄ To be considered in installations in potentially explosive atmospheres. Warning / Attention SET/DM3AL is a level switch sensor, which is to be connected to analogical and digital SET control units of Labkotec. Operating principle of the sensor is based on the measurement of electric conductance. SET/DM3AL sensor is suitable to be used as a level alarm device for liquids. It can be used to indicate the interface between oil and water or water and air. Typical applications of the sensor include oil and grease separators. The SET/DM3AL has been certified according to the ATEX Directive (94/9/EC) in equipment category 1 and it can be installed in potentially explosive atmospheres in zoned areas 0, 1, and 2. SET/DM3AL replace SET DM/3 sensor and it can be installed directly in its place. 2. TECHNICAL DATA Control unit: Signal Operating voltage SET-1000, SET-2000 control units by Labkotec Oy Analogical 3 ma/10 ma 8 V 16 V (DC) Cable: Shielded oil-proof cable 2 x 0.75 mm 2. Standard length 5 m. Other lengths optional. The max. length of the fixed cable is 15 m. Can be extended with a shielded cable. The recommended maximum cable loop resistance is 75 Ω. Material: PVC (black), AISI 316, NBR, PA Temperature range: Operation: 0 +60 C EMC Emissions Immunity IP-classification: Safety: -30 +60 C IEC/EN 61000-6-3 IEC/EN 61000-6-2 IP68 Ex-classification: Special conditions (X) Electrical parameters: ATEX IECEx Operating principle: II 1 G Ex ia IIA T5 Ga (Ta -30 +60 C) VTT 09 ATEX 026X IECEx VTT 10.0001X Ui = 16 V Ii = 80 ma Pi = 400 mw Ci = 3,5 nf Li = 85 µh Conductance Figure 1. Dimensional drawing of the SET/DM3AL-sensor Manufacturing year: Please see the serial number on the type plate. x xxx x xxxxx xx YY x where YY = manufacturing year (e.g.. 10=2010) The sensor may be installed in potentially explosive atmospheres of zones 0, 1, and 2 with the following special conditions (X): The ambient temperature is 30 +60 C. The risk of electrostatic charge must be observed! Standards to be considered in the installation: IEC/EN 60079-25 Intrinsically-safe electrical systems "i", and/or IEC/EN 60079-14 Electrical installations in hazardous areas. If the cabling is voltage-tested, the sensor must be disconnected from the system. Figure 2. Application: Oil alarm for the oil separator 2(5)

3. CONNECTIONS AND INSTALLATION The SET/DM3AL sensor is equipped with a shielded 2-wire cable. The numbered wires 1 and 2 of the cable are connected to the corresponding connectors (1 = +, 2 = - ) in the control unit. Unnumbered wire is connected to the cable shield. Always check the connections from the installation and operation manual of the control unit as well. In figure 3 the connection example 1; a LJB2-78- 83 junction box has been used to connect the cabling to the equipotential bonding. In figure 3 connection examples 2 and 3; equipotential bonding is not available. The shield is connected to the appropriate connector in the supply device. In these kinds of arrangements, it must be ensured that the electrostatic charges do not cause a hazard. Make sure in the installation that the device and cabling are not close to any strong current or other installations, and that they are not exposed to any strong stream flows, mechanical abrasions, or impacts. The cable may be shortened or extended with a junction box, if necessary. The sensor may be installed by hanging it from its cable (upper limit alarm) or immersed in the liquid to be measured (lower limit or interface alarms). The example in figure 3 shows an oil separator application in which the switch data is received when the upper electrode is covered in oil i.e. is no longer immersed in the conductive liquid. 4. OPERATION This chapter provides a general description of the operation of the oil alarm in different situations. For a more detailed description, please refer to the manual of the control unit in use. Normal mode Oil chamber full Fault alarm The SET/DM3AL oil level sensor is entirely immersed in water. The indicator lights are off. The relays are energized. The SET/DM3AL sensor is immersed in oil. (The sensor does not issue an alarm before the upper electrode is covered in oil. The alarm is issued at the latest when the entire sensor is immersed in oil.) The Oil chamber is full indicator lights up. The buzzer sounds The relays are de-energized. (Please note. A similar alarm is issued when the SET/ DM3AL sensor is in the air.) Once the alarm is off, the indicator lights switch off, the buzzer stops, and the relays are energized. The sensor is broken, there is a sensor cable break or a short circuit, or the sensor signal is not recognized (digital system). The sensor circuit s Fault indicator is on. The buzzer sounds. The relays are de-energized. Figure 3. Installation example in an oil separator. 3(5)

5. OPERATION TEST Always check the correct operation of the alarm after the installation and after making the connections. You should also check the operation every time the separator is emptied or at least once a year. Testing the operation 1. Immerse the sensor entirely in water. The device should be in normal mode (see chapter 4). 2. Lift the sensor in the air or immerse it in oil. The Oil chamber full alarm should be issued (see Chapter 4). 3. Put the sensor back into water. The alarm should stop after a while. Clean the sensor before installing it into the separator. If the sensor does not function as described, check the device settings from the control unit manual or contact the representative of the manufacturer 6. SERVICE AND REPAIR The sensor must be cleaned and tested when emptying the storage chamber and in connection with the annual maintenance. A mild detergent (e.g. washing-up liquid) and a scrubbing brush can be used for cleaning the sensor, if necessary. Also measure the output voltage of control unit. It is typically between 10-12 V with Labkotec Oy s SET-control units. See details from the manual of the control unit. In case of queries, please contact Labkotec Oy s service: labkotec.service@labkotec.fi. 7. SET/DM3AL and SET/DM3DL SENSORS SET/DM3AL sensor is designed to use with analogical SET-control units, such as e.g. SET-1000, OilSET-1000, SET-2000, SET-2000 Hi Level/Oil. SET/DM3DL -sensor is primarily designed to use with control units that communicate digitally, such as e.g. LevelSET S. Visually the difference of SET/DM3AL- and SET/DM3DL sensors is that SET/DM3AL sensor body is black and SET/DM3DL sensor body is grey. This operation and installation manual applies only to SET/DM3AL-sensor. During maintenance procedures (such as servicing the oil/fuel separator systems), the sensor should not be lifted out of the separator tank or installed back until there is water in the tank. The instructions concerning the inspection and maintenance of Ex equipment contained in the standards IEC/EN 60079-17 and IEC/EN 60079-19 should be observed when executing service, inspection, or repair procedures In fault situation check the cabling and connections of possible short-circuits or interruptions, then, if necessary, measure the sensor current and compare it with current values below. Attention! If the sensor is located in an explosive atmosphere, the multimeter must be Exi-approved! Sensor in the water: Sensor in the air: Sensor in the oil or grease: 3 4 ma 9 11 ma 9 11 ma 4(5)