MODEL: DV72 R & L. Mechanical Ventilation with Heat Recovery Installation Instructions and User Manual

Similar documents
Thank you for choosing EnviroVent

energisava 200 WALL & FLOOR MOUNTED VERSION INSTALLATION GUIDE FOR ENGINEER / INSTALLER

HOTLINE:

energisava 200 CEILING MOUNTED VERSION INSTALLATION GUIDE FOR ENGINEER / INSTALLER

DC Heat Recovery Unit MVHR Wholehouse heat recovery unit

SPECIFICATION casing manufactured from aludip steel in white low energy DC external motor aluminium plate heat exchanger

MODEL: BV400 Part No:

MEV SPIDER INSTALLATION GUIDE FOR ENGINEER / INSTALLER

Thank you for choosing EnviroVent

WHHR Midi & Midi Lite

Fusion HRV2 Mechanical Ventilation with Heat Recovery User / Homeowner Guide

"WHHR125DC" Whole House Heat Recovery Unit with Low Energy DC Motor. Installation, Operating and Maintenance Instructions domestic and commercial use

Installation and Maintenance Instructions for the Installer. Please refer to the User Manual for instructions on how to operate the system

Residential Carbon Friendly Ventilation SAP Q Eligible. ventilation

Unity CV2GIP Decentralised Mechanical Extract Ventilation (dmev) Installation Instructions

WHHR125DC - Aera. Whole House Mechanical Ventilation with Heat Recovery - MVHR

Installation and Maintenance

INTEGRA PLUS ABC. 230V~ 50Hz. Stock Ref. N. Installation and Wiring Instructions IPX2

MRXBOX95B-LOFT. Mechanical Ventilation Unit with Heat Recovery & Summer Bypass for Loft Mounting. Installation and Maintenance

Centair CMEV.4 / CMEV.4e / CMEV.4eHT Mechanical Extract Ventilation (MEV) System Installation Instructions

MRXBOX95-LH1/LH2. Mechanical Ventilation Unit with Heat Recovery for Loft Mounting Installation and Maintenance. Spigot 4.

Installation and Maintenance

MRXBOX95-WH1. Mechanical Ventilation Unit with Heat Recovery for Wall Mounting Installation and Maintenance. Intake air from outside

ELIX 1003 IPX4. Energy Efficient Centrifugal Fan with EC Motor Installation and Operating Instructions

MRXBOX95-WH1. Mechanical Ventilation Unit with Heat Recovery for Wall Mounting Installation and Maintenance. Bracket

Installation and Maintenance

Installation and Maintenance

Intake air from outside. Supply air to house. Extract air. from house. Extract air from house. Exhaust air from house to outside

Installation and Maintenance

Installation and Maintenance

Intake air from outside. Supply air to house. Extract air. from house. Extract air from house. Exhaust air from house to outside

Titon HRV1 Q Plus HRV1.5 Q Plus HRV2 Q Plus Heat Recovery Ventilation Units

CMX-S. Company name: Contact: Tel: Central Mechanical Extract Ventilation (cmev) appliance. Installation and Operating Instructions

MRXBOX95-WM2H. Mechanical Ventilation Unit with Heat Recovery and Integral Humidistat for Wall Mounting Installation and Maintenance

Purge Ventilation Unit. Product Manual. ventilation systems TP625

HRX-aQ Range. Mechanical Ventilation with Heat Recovery appliances. Installation and Operating Instructions

Slimline 150 & 300 Exceptionally low energy consumption. High Efficiency, Low Profile Heat Recovery Range

MRXBOX95-WM2. Mechanical Ventilation Unit with Heat Recovery for Wall Mounting Installation and Maintenance. Intake air from outside

ELEGANCE IPX4 IPX7. Low Carbon Fan with EC Motor Installation and Operating Instructions. 6 models:

MRXBOX95AB-WH1. Mechanical Ventilation Unit with Heat Recovery & Summer Bypass for Wall Mounting. Installation and Maintenance

isense & isense-ht 230V Flush Mounted Domestic Continuous Extract Fans

Model: Kair Whole House Ventilator Model Number: KHRVWH2000

Xcell 270 Longlife DC wholehouse heat recovery unit

Itho Advance heat recovery ventilation unit. comfortable. indoor climate

FAITH (dmev) 230V / 24V DC SELV Flush Mounted Domestic Continuous Extract Fans

VENTILATION. Mechanical Ventilation with Heat Recovery appliance. Installation and Operating Instructions. Models: HRX2-S, HRX2-B, HRX2-FP, HRX2-BFP

MRXBOXAB-ECO-LP1 100% Typical Installation. (including opposite handed versions)

Thank you for choosing EnviroVent

MRXBOXAB-ECO3 MRXBOX-ECO3

Green Line CMX. Central Mechanical Extract Ventilation (cmev) appliance. Installation and Operating Instructions. Model: CMX

Installation and Maintenance

MRXBOXAB-ECO2 MRXBOX-ECO2

Green Line HRX. Mechanical Ventilation with Heat Recovery appliance. Installation and Operating Instructions

Integra. Integra Plus EC MVHR. Installation & Commissioning. Stock Ref. N EC Integra Plus EC PLEASE RETAIN THESE INSTRUCTIONS WITH THE PRODUCT.

HRU ECO 3 RF APPENDIX Q ELIGIBLE NEW

energisava 200 High performance in a compact unit High Efficiency Whole House Heat Recovery System

MRXBOX95-WALL. Mechanical Ventilation Unit with Heat Recovery for Wall Mounting Installation and Maintenance. Extract air.

MRXBOXAB-ECO4 100% and Opposite Handed version. Typical Installation

HOTLINE:

Green Line HRX. Mechanical Ventilation with Heat Recovery appliance. Installation and Operating Instructions

Lo-Carbon MULTIVENT MVDC-MS & MVDC-MS H VENTILATION SYSTEMS V~50Hz. Installation and Wiring Instructions IP22. Stock Ref.

SUNWARM AIR SOLAR PRE-HEAT VENTILATION SYSTEM

EXTRACTOR HOOD. Please read all the instructions carefully before starting the installation. 230 / 240V 50Hz

Airflex Radial & ISO Thermal pipe

CI/SfB (57.5) November 2008

HRU ECO 4. System 4 Continuous Mechanical Supply and Extract Ventilation with Heat Recovery Appendix Q Eligible

MECHANICAL VENTILATION WITH HEAT RECOVERY (MVHR)

Code of Practice - Ventilation- Mechanical Extract Ventilation (MEV) + Mechanical Ventilation with Heat Recovery (MHVR)

9 inch and 12 inch Axial Fans Models MV230P, MV230AR and MV300AR Instructions for installation, maintenance and safe use.

ISCG90SS _03 ISCG90SS

Building Regulations 2010: What it means to you.

01 Safety. IMPORTANT Be sure to have read and understood these instructions before beginning the installation process.

Decentralised Mechanical Extract Ventilation 2 Speed Axial Extract Fan Installation Guide. Fig. 2 Fan components.

Domestic AC Fans 230V Installation and Operating Guide. eco. 230V AC Base Models: icon eco icon icon icon

"Microbox" DC Models MBOX 125/2DC MBOX 125/2DC204

November This product has been reconfigured Please read these instructions

airooncentre.co.uk irconcentre.co.uk Xpelair Low Energy Wall/Window Fan Range GX6 EC2 GXC6 EC2 Quick Order Hotline or

Ventilation Product range ADVANCE ECO 4 ECO 2

Trimbox Mixed Flow Fans. Product Manual. ventilation systems TP220T TP221T TP222T TP223T

MECHANICAL VENTILATION WITH HEAT RECOVERY (MVHR) NEW ECO RANGE

HRU ECO 3 RF APPENDIX Q ELIGIBLE NEW

Apartment Ventilation. "Microbox" Continuous Mechanical Extract Units

Lo-Carbon Sentinel Kinetic Horizontal

ART cm Island Curved Glass

HRV10 Q Plus TP440A TP440ABD TP440ABS. HRV10M Q Plus TP441A TP441ABD TP441ABS. Heat Recovery Ventilation Unit Product Manual

Wiring the fan correctly...

HRXD MVHR UNIT Mechanical Ventilation with Heat Recovery.

SH3020 USER INSTRUCTIONS

MRXBOX90 - WHOLE HOUSE HEAT RECOVERY UNIT

Issue5 07/13 USERS MANUAL IN-LINE MIXED FLOW

Mechanical Ventilation with Heat Recovery: Designing and implementing a robust and effective ventilation system

INSTALLATION INSTRUCTIONS USER GUIDE

Unity CV2GIP / CV2SVGIP Decentralised Mechanical Extract Ventilation (dmev) User / Homeowner Guide

Simply Silent Contour 4 (100mm) Axial Extraction Fan

EVP61/91/101/121. Extractor. Installation, use and maintenance.

HEAT RECOVERY AIR HANDLING UNIT

Wiring the fan correctly...

Decentralised Mechanical Extract Ventilation 2 Speed Axial Extract Fan with Humidity Enabler Installation Guide

Sentinel. Kinetic MVHR and Kinetic Plus MVHR. Installation & Commissioning

Centrif Duo & Centrif Duo Plus

Transcription:

90000556/90000557 Issue 10 9/17 MODEL: DV72 R & L Mechanical Ventilation with Heat Recovery Installation Instructions and User Manual Commissioning Data: to be completed by the installer Date of installation: Configuration Left Hand Right Hand Product Serial No: Important: This multi speed unit required Air Flow Rates to be adjusted when system is commissioned. This manual must be kept by the householder 1

Index General Information 3 Page About the Unit 4 Wiring Diagram 5 Technical Specifications 6 Installation Instructions 7-15 Commissioning 16 Check List 17 Maintenance 18 19 SAP Appendix Q Testing Results 20 22 Declaration of Conformity 23 Warranty 24 2

General Information To maintain a healthy indoor environment, closely controlled ventilation is essential. There are many pollutants that will affect the indoor air quality: human body waste products in the shape of CO 2, dead skin, perspiration and moisture. Add to this the waste products of cooking (cooking smells), showering (moisture), gases from building materials and the waste products of pets. Without proper ventilation this would be the perfect environment for the growth of mould, subsequent damage to the decoration and fabric of a home and to the health of its occupants. The Heat Recovery unit is fitted with two, low energy EC fans with a constant (100% adjustable) air volume. The exhaust fan ensures that warm, damp and polluted air as near as possible to the source is extracted. The exhausted air has to be replaced with fresh air, so the heat recovery unit not only has an exhaust fan, but is also fitted with a supply fan and air filters. The supply air, which in winter is colder than the inside air, is heated in the heat recovery unit using the heat of the exhaust air by means of the heat exchanger. This heat exchanger has a maximum efficiency of 91%, so a minimum loss of heat takes place and the supply air temperature enters the home at a comfortable level. In exceptionally cold weather or winter conditions it is possible that the exchanger may freeze due to sub-zero, cold incoming air. Therefore the unit must be sited in a frost-free location. Alternatively, an in-duct heater may be used to protect the heat exchanger from freezing. The filters in the unit ensure that the fresh supply air is clean as it enters the home. Also, the extract air from the property is filtered to protect the heat exchanger from unwanted contamination. These filters must be inspected regularly, initially every month, and cleaned. Each property will contaminate the filters at a different rate. The filters should be replaced annually or after a maximum of two cleaning cycles. Regular filter maintenance will ensure the integrity and performance of the unit. The unit s condensate drain must be installed and connected to the household drainage system and must be insulated if installed outside the insulated envelope of the building If the ductwork passes through an unheated area (loft or similar location), it must be insulated with an insulation material that complies with the latest Building Regulations. DO NOT switch off the unit it is designed to run continuously. If the unit is switched off, indoor pollutants and moisture levels may increase which could endanger your health or damage your home. In the event of a power failure or the unit being turned off, restart the unit at High Speed. This MVHR unit has a soft start. It is important to follow the advice in this user manual and correctly maintain the system to ensure a healthy indoor environment. 3

About The Unit Duplexvent DV72 R & L are complete heat recovery units to ensure optimum efficiency for your home. The units are supplied as left or right hand options. See page 11 Standard wall mounting kit is supplied with each unit. For fitting see page 9-12. Optional horizontal floor mounting is also available. See pages 13-15 The units are supplied as standard with: Frost protection, boost function, thermal bypass and remote commissioning panel. Mounting plate Wall bracket EXPLODED VIEW Spigot Heat recovery cell Spacers Fixing rods Front cover Motor assembly Front shell Drain Filter & Filter plugs Remote control 4

Wiring Diagram Commissioning Electrical connections. 1. All wiring must conform to BS 7671 : Latest edition IEE wiring regulations. 2. This appliance is suitable for 230V~ 50Hz single phase supply fused at 3 amp. 3. The appliance must be earthed and a double pole switch having a minimum contact separation of 3.0mm must be used to provide isolation for the unit. 4. The unit is supplied with a 1.5 meter long, 8 core cable for remote control connection. There is a risk that a longer cable may act as an aerial causing electronic interference problem to the unit. ( 8 Core Signal Cable 0.22CSA Non Shielded ). Remote Control Cable Connections. 5. Four core mains supply cable minimum size 0.75CSA. 6. Upon Installation the fans should be started in High Speed mode to ensure optimum performance of fans and then adjusted to the required continuous ventilation setting. 7. The remote controller must not be mounted above or within 1 meter of a cooker where it could be affected by excessive heat or moisture. Emergency shutdown details - Unit to be isolated Switch live must also be isolated/disconnected before opening the unit 5

Technical Specifications Maximum Flow Rate 75 l/s (270m 3 /h) MAX* Protection Class IPX2 Heat Exchanger Counter Flow (Plastic) Thermal Efficiency 91% Supply Filter Extract Filter G3 G3 Fans EC (Electronically Commutated DC) Spigot Ø 125mm Electrical Supply 230V/1PH/50Hz Dimensions 560 x 635 x 260mm Max Power Consumption 140W Weight 14kg Duplexvent Static Pressure - Airflow 6

Installation Instructions IMPORTANT Be sure to have read and understood these instructions before beginning the installation process. PRE-INSTALLATION CHECK LIST Make sure that the unit can physically fit in to the desired location. The Duplexvent unit should be situated so that access for maintenance or replacement of parts and filters is possible. The Duplexvent unit is suitable for conventional rigid ducting or low energy radial duct system Airflow Development Airflex Pro system. If using conventional ducting ensure duct runs are as short as possible, having the most direct route and using as few bends as possible. This is to reduce system pressure. SAFETY AND RECOMMENDATIONS All wiring must comply with Building Regulations and the current I.E.E. Wiring Regulations (BS7671) or the equivalent standards for your country. The final installation should be examined and tested by a qualified electrician. Precautions must be taken to avoid the back-flow of gases into the dwelling from the open flue of gas or other fuel-burning appliances. Make sure the mains supply complies with the rating label for voltage, frequency and phase. Children shall not play with the appliance. Cleaning and user maintenance shall not be made by children without supervision. If any cables are damaged they must b replaced by the manufacturer, its service agent or similarly qualified persons 7

Installation Instructions Control Options Frost Protection When the cell temperature in the unit falls below 3ºC the unit automatically warms the cell with extracted air to prevent the formation of frost. Boost - Switched Live The unit comes with Switched Live as standard. It is an automatic function, sending the unit to boost when the bathroom or kitchen light is on, or boost switch is activated. Summer Bypass Control Options Frost Protection Boost Switched Live Thermal Bypass The summer bypass helps reduce the air temperature coming into the dwelling during the summer months. It is an automatic function and operates when the supply air temperature to the property is above 25ºC. 8

Installation Instructions FIRST FIX - Installing ductwork and electrical supply Important note: This unit is for wall or floor mount only. Ceiling mounting unit are configured differently and should be ordered separately. 1. Locate external terminations (supply and extract) in accordance with the latest addition of the Domestic Ventilation Compliance Guide. 2. Ductwork from the unit is Ø125mm dia. - maximise duct size where possible. Make sure that the ductwork is insulated in unheated spaces. Minimise flexible duct. 3. Locate the mains supply within 1m of the location of unit. The position of the electrical power supply or unit (a fused switched isolator) must not be mounted above or closer than 1m to a cooker where it could be affected by excessive heat or moisture. 4. Make sure that there is room for the MVHR unit. The unit is designed to be wall mounted. It can also be floor mounted with an additional kit. Part number 90000558 5. Also make sure that there is a free space at the front of the appliance for cleaning the filter and carrying out maintenance on the appliance. Ducting Configuration See page 11-15 for duct connections to the unit/air flow directions Radial Duct System Installed example, RH unit shown. A No exhaust within 2m of air inlet B Inlet duct from atmosphere C Outlet duct to atmosphere D MVHR E Ducts to and from property F Condense Drain Note: Important if installed in a loft space the area should be within the insulated envelope to maintain optimum performance 9

Installation Instructions SECOND FIX Installing Vertically Hung unit 1. Attach the wall bracket to a flat stable surface that is capable of bearing the unit s weight, 12Kg. Ensure that the bracket is positioned so that there is enough space for the condensate drain and ducts to be connected. Fixing kit provided. Raw Plugs x 5 3. Slide the unit onto the wall bracket and attach ducting and drain. Pre fixed bracket on the back of the Duplexvent unit Wall bracket Screws x 5 Connect 22mm PVC drain fitting 2. Attach spacers x 2 with screws provided. The spacers ensure that the unit tilts forward to improve drainage. Use the tie down cable if required to secured the bottom of the unit. Anti Vibration Mount Foam casing 4. The drainage from the unit may be connected to an internal waste water system or soil pipe with an appropriate non-return device. One way valve device is recommended. Insulate pipes in an unheated loft space. Wall fit only 10

Installation Instructions SECOND FIX installing Vertically Hung Unit Airflow and drain fitting - LH Airflow and drain fitting - RH To atmosphere From atmosphere Extract from dwelling Supply to dwelling Supply to dwelling Extract from dwelling From atmosphere To atmosphere Wall mount Wall mount Drains are factory fitted. The units has either a LH or RH drain. 11

Wall mounting bracket dimensions Please note that there is only one loose bracket with the two tab bracket factory fitted. Picture of Tie Down Cable. 12

Horizontal mounting bracket dimensions 13

Installation Instructions SECOND FIX Installing Horizontal Mounted Unit Connect 22mm PVC drain fitting Floor mounting 5. The unit can be floor mounted by using the horizontal mounting kit, Part Number 90000558 Use the long and short S brackets provided along with short fitting screws to ensure correct drainage. The unit must be higher at the duct end. Bracket fixing position. See Page 13 6. Mount the remote control near the unit. Fix securely to a flat surface. For maintenance please ensure the remote control is disconnected before removing the unit from the wall. X2 X2 Drain connections should be solvent welded as here. The center Tee section is reversed to make either LH or RH drain. Push in the drain fitting and seal as appropriate to create a watertight assembly. RH When fixing the remote control please ensure the ribbon cable is in place (contacts down, red side up) up). LH Important note: The floor mounted drain must be fitted on the same side as the factory fitted drain. This unit is for wall or floor mount only. Ceiling mounting units are configured differently and should be ordered separately. 14

Installation Instructions SECOND FIX - Drainage for floor mounted units Floor mount - LH drain Floor mount - RH drain To atmosphere Extract from dwelling From atmosphere Supply to dwelling To atmosphere Extract from dwelling From atmosphere Supply to dwelling Place stopper provided into the fitted drain Place stopper provided into the fitted drain Ø20mm Saw Ø20mm Saw Drill into the case as shown, using the metal plate as a guide. Ensure that the foam core is fully removed. 15

Commissioning Setup guide for the Duplexvent The commissioning the remote switch. panel is found on the Commissioning mode is chosen by pressing the SET button for 4 seconds, all sensor inputs will be disabled in this mode so that they do not interfere with flow rates. All LEDs will light with the Extract Boost flashing (Ext B), this indicates that the flow rate may now be increased/decreased as required. The next press of the SET button will move commissioning to the next setting, Sup.B and so on. When the unit has been fully commissioned, press the SET button for 4 seconds and this will put the unit back into status mode. If the unit is not put back into status mode after commissioning, it will automatically revert back to status mode after an hour. Note: Settings will be retained if the power supply is interrupted. LED Indications Constant LED Flashing LED (A) Frost protection ON (B) Boost state - Humidity ON (C) Boost state - switched input ON (D) Summer by-pass ON (A) Service required (B) Service required (C) N/A (D) Check filter* Supply and extract LED indications *To clear the filter indication light press the minus button [-] for 10 seconds 16

Checklist Installation instructions have been understood Ducting Ø125mm or larger has been used from the unit The unit is securely fixed into position with enough space left for servicing Condense drain is tight, drains to a suitable location and has been water tested 17

Maintenance Pack of 2 x filters. Part number 9041511 Filter cover Front cover General advice: Regular filter inspection is recommended. Minimum recommendation is to check filters every 6 months. Some installations will need more frequent filter inspection to ensure maximum efficiency of unit. Filter Maintenance recommendation: 1. 2. 3. 4. 5. 6. 7. Switch off the power supply Remove front panel Remove filter covers Remove the filters Vacuum the outside of the filter or replace if required After cleaning replace filters at same side Replace filter covers and front panel Major service: This is to be carried out every five years (minimum) by an approved maintenance company. 18

Maintenance Disassembly of unit for engineering access and maintenance: 1. Remove the velcro pads. front cover...held on with 3. Carefully remove the top foam moulding by pulling it straight forward. Foam mouldings must remain parallel. Take care gaskets. not to damage the sealing 2. Remove retaining screws and washers x 4, store safely. Do not pull from one edge as this may damage the internal fixing rods. When reassembling the unit should be, after maintenance, ensure there are no trapped wires and that seals are intact. 19

SAP Appendix Q Testing Results Central mechanical supply and exhaust ventilation system packages with heat recovery used in a single dwelling Brand Name Model Model Qualifier (if applicable) Current Manufacturer and Contact Details Original Manufacturer (if different) Name Address Airflow Duplexvent DV72R and DV72L Airflow Developments Ltd Lancaster Road Cressex Business Park High Wycombe HP12 3QP Telephone 01494 525252 Website First Year of Manufacture 2015 Last Year of Manufacture Testing Body www.airflow.com BRE Date of test 22/03/2010 Serial Number of Product Tested MVHR to outside grille duct types and size Duct types and sizes used for supply and exhaust 5780 EC 150 & 125 mm diameter rigid plastic and 200 mm diameter rigid plastic 150 & 125 mm diameter rigid plastic and 200 mm diameter rigid plastic Results of leakage tests Table Q1 Internal External Pass Pass 20

Results for SAP calculations (at minimum flow rate condition) This product has only been tested with rigid ductwork and the data are not applicable for SAP calculations if installed with flexible ductwork. Table Q2 Systems with rigid ductwork only Exhaust terminal configuration Fan speed setting Specific fan power (W/l/s) Heat exchange efficiency (%) Energy Saving Trust Best Practice Performance Compliant Kitchen + 1 additional wet room Kitchen + 2 additional wet rooms Kitchen + 3 additional wet rooms Kitchen + 4 additional wet rooms Kitchen + 5 additional wet rooms 100% Variable 100% Variable 100% Variable 100% Variable 100% Variable 0.73 91 Yes 0.72 90 Yes 0.79 89 Yes 0.93 88 Yes 1.06 87 No These figures are entered into either: (a) In the case of SAP software amended to SAP 2005 version 9.81 allowing direct entry of MVHR data, the SAP software, or (b) In the case of SAP software amended to SAP 2005 version 9.81 not allowing direct entry of MVHR data, the SAP Q MVHR Calculation Spreadsheet v9.81 and the results from the spreadsheet into the Special Features part of the SAP 9.81 software, or (c) In the case of SAP software to SAP 2005 version 9.80, the SAP Q MVHR Calculation Spreadsheet v9.80 and the results from the spreadsheet into the Special Features part of the SAP 9.80 software. They must NOT be entered directly into SAP 2005 version 9.80 software 21

Table Q3 Systems with flexible ductwork only Exhaust terminal configuration Fan speed setting Specific fan power (W/l/s) Heat exchange efficiency (%) Energy Saving Trust Best Practice Performance Compliant Kitchen + 1 additional wet room N/A N/A N/A N/A These figures are entered into either: (a) In the case of SAP software amended to SAP 2005 version 9.81 allowing direct entry of MVHR data, the SAP software, or (b) In the case of SAP software amended to SAP 2005 version 9.81 not allowing direct entry of MVHR data, the SAP Q MVHR Calculation Spreadsheet v9.81 and the results from the spreadsheet into the Special Features part of the SAP 9.81 software, or (c) In the case of SAP software to SAP 2005 version 9.80, the SAP Q MVHR Calculation Spreadsheet v9.80 and the results from the spreadsheet into the Special Features part of the SAP 9.80 software. They must NOT be entered directly into SAP 2005 version 9.80 software Results for Approved Document F (at maximum flow rate condition) Table Q4 Exhaust terminal configuration Fan speed setting Total exhaust flow rate (l/s) Total supply flow rate (l/s) Kitchen + 1 additional wet room Kitchen + 2 additional wet rooms Kitchen + 3 additional wet rooms Kitchen + 4 additional wet rooms Kitchen + 5 additional wet rooms 100% Variable 100% Variable 100% Variable 100% Variable 100% Variable 15.0 15.0 21.0 21.0 27.0 27.0 33.0 33.0 39.0 39.0 Comments Only figures from Table Q2 or Table Q3, not both, should be used with the SAP Q Calculation Spreadsheet for this technology type. Table Q4 results are only applicable for Approved Document F requirements. 22

Declaration of Conformity We declare that the equipment detailed below conforms to the requirements of the EC council directives relating to electromagnetic compatibility and safety of electrical equipment. Equipment type: Supplied by The Heat Recovery Appliance Model: DV72 Airflow Developments Limited Aidelle House, Lancaster Road Cressex Business Park High Wycombe Buckinghamshire HP12 3QP T: +44 (0) 1494 525252 Visit: airflow.com Description of equipment: Relative EC Council Directives: Mechanical Heat Recovery Ventilation Unit 2004/108/EC (EMC) 2006/95/EC (LVD) Applied Harmonised Standards: EN 60335-1:2002/A2:2006 EN 60335-2-80:2003/A1:2004 BS EN 308:1997 EN13141-7:2004 Airflow Developments Limited warrants that heat recovery appliances are manufactured from high quality materials and that continuous quality control ensures that they comply with the above directive. 23

This product has a warranty period of one year. Warranty The warranty only covers the product and not the installation cost. In case such a fault in the manufacture becomes apparent during the Warranty Period, Airflow may, at its absolute discretion, repair the product free of charge or refund the cost of the product AS LONG AS AND ONLY IF: 1. The product is returned within the Guarantee Period with evidence of purchase date 2. The product has not been misused or handled carelessly or used on an inappropriate voltage supply 3. Repairs have not been attempted other than by Airflow s service staff or 4. In Airflow s sole discretion, the product is found to be faulty. If it were not found to be faulty, the product would be available for collection from the relevant Airflow premises within one calendar month and if it was not collected, it would be subsequently delivered by Airflow and a delivery charge will be made. 5. Has been installed in accordance with the latest Building Regulations and IEE Wiring Regulations. This warranty does not confer any rights other than those expressly set out above and does not cover any claims for consequential loss, damage or any costs incurred in the replacement of the faulty product. This warranty is offered as an extra benefit and does not affect your statutory right as a consumer. All information believed correct at time of going to press. All goods are sold according to Airflow Developments Limited s Standard Condition of Sale which is available on request. In the interest of continuous development Airflow Developments Limited continuously strive to improve their products and reserve the right to change specifications and prices without prior notice. Airflow Developments Limited Aidelle House, Lancaster Road Cressex Business Park, High Wycombe Buckinghamshire. HP12 3QP. UK E-mail: info@airflow.com Telephone: +44(0)1494 525252 Facsimile: +44(0)1494 461073 Copyright 2015. Airflow Developments Ltd 24