Next MTR kw. technicalcatalogue. Air conditioners for Metrology Labs with upflow air delivery T_NXTMTR_0511_GB

Similar documents
Next P kw COOLING 5 93 kw HEATING. technicalcatalogue. Heat pump air conditioners with upflow air delivery T_NXTP_0411_GB

NEXT EVO DXR410A NEXT EVO DX NEW SOFTWARE. rcgroupairconditioning

4,5 22,5 kw. technicalcatalogue. Air-conditioned server-racks for direct installation into the room T_CLSEVO_0113_GB

kw COOLING kw HEATING

NEXT DL NEXT DL. rcgroupairconditioning

COOLROW Close control air conditioners for In-Row installation Cooling Capacity: kw

Packaged air cooled liquid chillers for outdoor installation kw. technicalcatalogue T_EGL_1012_GB

next p dw next p dw rcgroupairconditioning

MULTIPLO PF Multifunction chillers for indoor installation. Cooling Capacity: kw Heating Capacity: kw

SMART. 4,9 49,5 kw. Air cooled liquid chillers and heat pumps equipped with scroll compressor and axial fans T_SMT_0609_GB

21,8 222 kw COOLING 25,2 236 kw HEATING

EASY_R R407C. Air cooled liquid chillers and heat pumps equipped with scroll compressor and axial fans. 5,2 41,5 kw T_ESY_R_0508_GB

44,9 202,0 kw. technicalcatalogue

next evo cw next evo cw rcgroupairconditioning

kw. technicalcatalogue

kw. technicalcatalogue

next DX.U.S* 052.Z2.H6.DC

EQEF TECHNICAL CATALOGUE AIR COOLED WATER CHILLERS AXIAL FANS WITH FREE-COOLING SYSTEM

unico pf unico pf rcgroupairconditioning

pyxis u pyxis ua NEW rcgroupairconditioning

NEMO A Split-system liquid chillers for indoor installation. Cooling Capacity: 5 26 kw

EQSL TECHNICAL CATALOGUE AIR COOLED WATER CHILLER UNITS AXIAL FANS. Models: 300 V2 F V2 F16. Cooling capacity: 299 to 1310 KW

EQUH PF PACKAGED HEAT PUMP AIR/ WATER LIQUID CHILLER FOR INDOOR INSTALLATION

pyxis hp "u" pyxis hp "u" IDEA NEW rcgroupairconditioning

PYXIS U PYXIS U. rcgroupairconditioning

pyxis pyxisa NEW rcgroupairconditioning

pyxis cla pyxis cla A-CLASS NEW rcgroupairconditioning

i-next DX kw FULL INVERTER direct expansion air conditioners for IT Cooling. To be matched with remote air-cooled condenser. rcitcooling.

GLIDER EVO FREE GLIDER EVO FREE GLYCOL FREECOOLING. rcgroupairconditioning

glider evo cla glider evo cla A-CLASS rcgroupairconditioning

GLIDER EVO GLIDER EVO. rcgroupairconditioning

nemo a hp rcgroupairconditioning R410A

GLIDER EVO CLA GLIDER EVO CLA HIGHEFFICIENCY ACLASS. rcgroupairconditioning

EQPHU PACKAGED HEAT PUMP AIR/ WATER LIQUID CHILLER FOR OUTDOOR INSTALLATION

FRIGO SCREW CLA PLUS Packaged water cooled liquid chillers in A+ class energy efficiency for indoor installation. Cooling Capacity: kw

unico turbo FL unico turbo FL LOW NOISE A-CLASS INVERTER rcgroupairconditioning

UNICO TURBO FL FREE UNICO TURBO FL FREE HIGHEFFICIENCY INVERTER ACLASS FREECOOLING LOWNOISE. rcgroupairconditioning

rcgroup.it Flooded evaporator Refrigerant charge HFO1234ze, GWP<1 Low noise Minimum starting current EER up to 5,41 ESEER up to 9,10

rcgroup.it Flooded evaporator Low noise Minimum starting current EER up to 5,25 ESEER up to 8,88

KELVIN Clim F497. Kelvin air conditioning

SLS 1202 to With or without total heat recovery. u Air Cooled Screw Chillers. 262 to 916 kw. Engineering Data Manual

> Refrigerant R-410A. Uniflair LE TDER-TUER kW. Energy-saving units with backward-curved fans. Perimeter cooling for medium/large data center

2013 Product Range Precision Air Conditioners (CRAC)

frigo turbo FL Chillers

Chilled Water Precision Air Conditioner for Critical Application

Kelvin air conditioning. KELVIN Clim W280. Cooling Capacity: 280 ~ 1840 kw

Epsilon Echos kw. General information Air-Water unit with scroll compressors driven by DC inverter. Unique selling points

Zeta Rev LN HP Prochill Bluebox Print Date: 07/17/2017

AIRSYS-P-SC-CHILLROW-E1503V01.1 CHILLROW. Row Cooling Precision Air Conditioner. Cooling Capacity: 26.2kW~68.6kW

next NEXT EVO CW kw UP FLOW DOWN FLOW CHILLED WATER E C CLOSE CONTROL AIR CONDITIONERS FOR CHILLED WATER FEEDING,

ED.X F Kc DIRECT EXPANSION CLOSE CONTROL UNITS WITH REMOTE CONDENSERS AND ADDITIONAL CHILLED WATER FREE COOLING COIL

CMA TECHNICAL MANUAL CONDENSING UNITS FOR OUTDOOR INSTALLATION O L S A F RA N

Kelvin air conditioning. KELVIN Clim W250. Cooling Capacity: 250 ~ 1240 kw

WATER COOLED HEAT PUMP VERTICAL UNIT CONSOLE TYPE OR RECESSED

AIR COOLED CHILLERS WITH SCROLL COMPRESSORS AND CENTRIFUGAL FANS

GPE Kc UNITS FOR 4-PIPE SYSTEMS WITH SCROLL COMPRESSORS. COOLING CAPACITY FROM 77 TO 426 kw - 2 COOLING CIRCUITS. GPE 802 Kc + CF + GP + MV + P1

YORK Close Control units

WATER CHILLER UNITS AIR COOLED CONDENSER CENTRIFUGAL FANS HEAT PUMP. EWCBZ COOLING ONLY. EWCZ

Kälte Klima. Air cooled liquid chiller Free-Cooling from 45 kw to 385 kw. Scroll Compressors SCAEY-FC DE 98

FHE FHE. Dehumidifiers for radiant cooling systems with heat recovery. Versions

AIR COOLED CHILLERS FOR OUTDOOR INSTALLATION WITH INTEGRATED FREE COOLING MULTISCROLL SERIES

Kälte Klima. Air cooled liquid chiller Free-Cooling from 45 kw to 365 kw. Scroll Compressors SCAEY-FC DE 98

CMA CONDENSING UNITS FOR OUTDOOR INSTALLATION INSTALLATION AND OPERATION MANUAL

Air cooled industrial chillers

Большая библиотека технической документации каталоги, инструкции, сервисные мануалы, схемы.

Technical Catalogue. Air-Cooled Liquid Chillers with screw compressors Nominal cooling capacity: kw 50 Hz

Vertical self-contained air conditioner

Kälte Klima. Air cooled water chillers air cooled reversible heat pumps from 45 kw to 320 KW. Compressors Scroll SCAEY DE 88 04/11 12/10

BRAN Residential chillers and heat pumps. Reversible unit, air source for outdoor installation 4,81-27,2 kw <<< BACK INDEX.

AIR COOLED CHILLERS WITH SCROLL COMPRESSORS AND CENTRIFUGAL FANS

RAH Ka AIR COOLED WATER CHILLERS WITH SCREW COMPRESSORS AND AXIAL FANS. COOLING CAPACITY FROM 387 TO 1207 kw 1 AND 2 COOLING CIRCUITS

Blue Box Epsilon Echos +

RAS Kp AIR COOLED CHILLERS WITH RECIPROCATING COMPRESSORS AND AXIAL FANS REFRIGERANT R290 LIQUID CHILLERS - AIR COOLED AIR


AIR COOLED FREE-COOLING CHILLERS WITH SCROLL COMPRESSORS AND AXIAL FANS

GHE Dehumidifiers for radiant cooling systems with heat recovery

CZT CZT. High efficiency air to water heat pumps with E.V.I. compressors E.V.I. HP OTHER VERSIONS ACCESSORIES

LSK LSK. Air to water chillers and heat pumps VERSIONS ACCESSORIES

turb new unico turbo frigo turbo fl Liquid chiller equipped with magnetic levitation twostage centrifugal compressors RCGROUP SpA C_GNR_0711

LDK LDK. Air to water chillers and heat pumps VERSIONS ACCESSORIES

DATATECH. Precision air conditioners for technological environments 6 220

Air cooled chillers. Air cooled chillers with brushless oil-free compressors. RAC. Ka Series - 1 or 2 cooling circuits capacity from 300 to 1400 kw

ERAH MC Ka. Range kw. AIR COOLED CHILLERS WITH SCREW COMPRESSORS AND AXIAL FANS FOR OUTDOOR INSTALLATION (Standard line)

york airside products Tailored air conditioning solutions Introducing the YORK YPRE range of custom air-to-air packaged roof top units

RC GROUP. MULTIPLO.A.STD/ELN G Multifunctions air cooled liquid chillers with Scroll compressors and axial fans R407C. SCROLL compressors kw

LZT High efficiency air to water heat pumps with E.V.I. compressors

EXPAIR. Use. Precision air handling cabinets. Reducted footprint Dual-wall construction

MAGISTER. Compact and attractive design Energy savings with EC motor and self-regulating control. Easy to install. Use. Chilled water operation

CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 47 to 78 kw

GHE GHE. Dehumidifiers for radiant cooling systems with heat recovery VERSIONS ACCESSORIES

TOTAL HEAT RECOVERY MULTI-PURPOSE HEAT PUMPS

LZA High efficiency air to water heat pumps with HP compressor

Precision air handling cabinets Ciatronic MICRO/EXPAIR

> HGA AIR - WATER HEAT PUMPS FOR OUTDOOR INSTALLATION. Available range. Unit description. Options. Accessories

WATER TO AIR DUCTABLE INDOOR HORIZONTAL HEAT PUMP

Water chillers water/water type SIGMA Technical information manual

Aquaflair TRAC-TRAF-TRAH

Roof top SPACE RPC 450Z R407C M011

DUCTED UNITS EBH EDS INTEGRATED COMFORT SYSTEMS

TECNAIR LV C series Close control air conditioners

Transcription:

6 15 kw Next MTR Air conditioners for Metrology Labs with upflow air delivery technicalcatalogue T_NXTMTR_0511_GB

INDEX GENERAL CHARACTERISTICS... 3 SERIES IDENTIFICATION... 3 MODEL IDENTIFICATION... 3 WORKING RANGE... 4 WORKING LIMITS... 5 MAIN COMPONENTS... 6 OPTIONAL ACCESSORIES... 8 TECHNICAL DATA - NEXT MTR DX... 9 TECHNICAL DATA - NEXT MTR DW... 10 ELECTRICAL DATA... 17 MP.COM: MICROPROCESSOR CONTROL SYSTEM... 18 OPTIONAL ACCESSORIES REMOTE AIR COOLED CONDENSER... 19 OPTIONAL ACCESSORIES - CONDENSATE DISCHARGE PUMP... 21 OPTIONAL ACCESSORIES - FLOOR STAND... 22 OPTIONAL ACCESSORIES - BOTTOM PANEL... 23 OPTIONAL ACCESSORIES - SANDWICH PANEL... 23 OPTIONAL ACCESSORIES - NON RETURN MOTORIZED DAMPER... 24 OPTIONAL ACCESSORIES - AIR DELIVERY PLENUM... 25 OPTIONAL ACCESSORIES MP.COM REMOTE TERMINAL... 26 MACHINE DRAWINGS... 27 TYPICAL INSTALLATION DIAGRAMS FOR DIRECT EXPANSION MACHINES WITH REMOTE AIR COOLED CONDENSER... 29 EXAMPLE FOR MACHINES NOISE EMISSION CALCULATION... 31 2 RC GROUP S.p.A. T_NXTMTR_0511_GB R407C

GENERAL CHARACTERISTICS NEXT MTR: Air conditioners for metrology labs with upflow air delivery. The series is suitable for all applications where high precision is required in maintaining the characteristics of temperature-humidity of the air conditioned room as laboratories, clean rooms, rooms for precision measurements etc.. The machines are made for indoor installation. The constructive solutions and the internal lay-out allow high application flexibility and the frontal access to the main components for the inspection and routine maintenance. Machines supply fully assembled with refrigerant charge and control systems. The installation requires electrical and hydraulic /refrigerant connections only allowing high costs and time reduction. Final assembly on all machines before shipment including running test, reading and monitoring of operating parameters, alarms simulation and visual check. Design, assembly and test as per the Company Quality Assurance program in full compliance with ISO 9001. RC Group has been the first Italian company in its segment to get the ISO 9001 in October 13 th, 1991 with certificate ICIM 0018. The machines are in full compliance with European Norms 2006/42CE, 2006/95CE, 2004/108CE, 97/23CE and subsequent amendments. SERIES IDENTIFICATION Frontal air suction and upflow air delivery. NEXT MTR DX: Direct expansion air conditioners for metrology labs, for matching with remote air cooled condenser, and equipped with scroll compressors and Plug-fans. Cooling capacity 6,6 14,4 kw NEXT MTR DW: Direct expansion close control air conditioners for metrology labs, with built-in water cooled condenser and equipped with scroll compressors and Plug-fans. Cooling capacity 7,0 15,3 kw MODEL IDENTIFICATION NEXT MTR DX O 013 Z 1 H3 DX Machine type DX direct expansion air cooled DW direct expansion water cooled O Air delivery O upflow 013 Cooling capacity (kw) at nominal conditions Z Compressor type Z Scroll hermetic compressor for R407C 1 Number of compressors H3 Cabinet size RC GROUP S.p.A. T_NXTMTR_0511_IT R407C 3

WORKING RANGE The machines are designed to maintain a room temperature between 20 and 26 C (±0.5 C) with a relative humidity between 45 and 55% RH (± 3%). The room has to be closed and with a good thermal insulation as clean rooms, metrology labs, etc. It is possible to extend the operating range from a minimum of 16 C up to a maximum of 32 C with relative humidity from 40 to 60% RH. CAUTION In these operating conditions (gray area in the graph) precision and accuracy of the control are reduced: - Temperature: ± 1 C - Humidity: ± 5%rH. Not recommended operating condition (% rh) 60 RECOMMENDED OPERATING CONDITION 55 Room humidity 50 45 40 15 20 25 30 35 ( C) Room air temperature REMOTE AIR COOLED CONDENSER CONDENSING CONTROL IN COOLING MODE CONDENSING CONTROL WITH PHASE-CUT ELECTRONIC REGULATORS MIN fans speed On/Off working mode MIN fans speed proportional condensing control MAX fans speed MAX fans speed -15-10 -5 0 5 10 15 20 25 30 35 40 ( C) Ambient temperature The values are indicative. The working temperatures are influenced by a series of variables as: Working conditions Thermal load Cleanness status of the condensing coils Set of the microprocessor control WATER COOLED CONDENSER Water temperature: 30/50 C Outlet temperature range. 4 RC GROUP S.p.A. T_NXTMTR_0511_GB R407C

WORKING LIMITS Room air temperature: 14 C minimum temperature with wet bulb. 24 C maximum temperature with wet bulb. 35 C maximum temperature with dry bulb. Room air humidity: 20%RH minimum relative humidity. 75%RH maximum relative humidity. STORING TEMPERATURE If the machine is not installed on receipt and is stored for a long time, store it in a protected place, at temperatures ranging between -30 C and 50 C in absence of superficial condensation and direct sun light. RC GROUP S.p.A. T_NXTMTR_0511_IT R407C 5

MAIN COMPONENTS FRAMEWORK Base in aluminium extrusion, painted with epoxy powders. Inner frame and upper frame in aluminium profile, painted with epoxy powders. The inner frame is provided with seals to ensure air tight with the panels. Galvanized steel sheet panels externally coated with PVC film and internally insulated with noise absorption material. The panels are fixed to the frame with non visible mounting system. Electric board in separate technical compartment on the machine front. Colour: RAL 9005 for base and frame Similar to RAL7015 for panels, with hammered finish Air intake from the front through honeycomb type grille and air delivery from the top. Washable air pre-filters with G2 efficiency, with cells in synthetic fibre. COMPRESSORS Orbiting spiral (SCROLL) hermetic compressors with spiral profile optimized for R407C refrigerant. Continuous control of the cooling capacity by hot gas by-pass. 2-pole 3-phase electric motor with direct on line starting. Crankcase heater. Electric motor thermal protection via internal winding temperature sensors. Terminal box with IP54 enclosure class. Rubber supports. FILTER SECTION Washable air filters with G4 efficiency, with cells in synthetic fibre and metallic frame (EN 779-2002). EVAPORATING SECTION Heat exchanger coil with internally corrugated copper tubes and high efficiency aluminium fins, specifically developed to provide high heat transfer and lower pressure drops. Cooling capacity control. Frame in galvanized steel. Condensate tray in peraluman with PVC flexible discharge pipe. HEATING SECTION 3 working steps electric heater consisting of aluminium armoured elements with integral fins and safety thermostat (binary control logic). Modulating type hot gas reheating system. HUMIDIFICATION SECTION Proportional controlled steam humidifier with immersed electrodes fitted with safety and running accessories. DE- HUMIDIFICATION SECTION Dehumidification system with automatic air flow reduction. FANS SECTION Centrifugal fans with backward curved blades, single suction and without scroll housings (Plug-fans), directly coupled to external rotor electric motor. Brushless type synchronous EC motor with integrated electronic commutated system and continuous variation of the rotation speed. The motor rotation control is obtained with the EC system (Electronic Commutation) that manage the motor according to the 0 10V proportional signal coming from the microprocessor control. Temperature/humidity sensors on air intake. REFRIGERANT CIRCUIT Thermostatic expansion valve. Sight glass. Filter dryer on liquid line. Pressure transducers with indication, control and protection functions, on low and high refrigerant pressure. High pressure safety switch with manual reset. Safety valve. Liquid receiver with accessories. 3-way modulating valve for hot gas re-heating system. Check valve for hot gas re-heating system. 6 RC GROUP S.p.A. T_NXTMTR_0511_GB R407C

Hot gas injection valve for capacity control. Balancing valve for hot gas capacity control. Refrigerant circuit with copper tubing with anticondensate insulation of the suction line. Plastic capillary hoses for pressure sensors connection. R407C refrigerant charge. NEXT MTR DX: - Valves on gas delivery and liquid return for coupling to remote air cooled condenser. - 0 10V proportional signal to manage the condensing control system of the remote air cooled condenser. NEXT MTR DW: - Copper brazed plate type with cover plates, plates and connections in AISI 316 stainless steel. - 0 10V proportional signal to manage the condensing control system of the 2- way motorized valve. ELECTRICAL PANEL In accordance with EN60204-1 norms complete with: Main switch with door lock safety. Magnetothermic switch for supply fan, compressor, electric heaters and humidifier. Contactors for each load. The supply fans equipped with EC electric motor are not supplied with contactors. Transformer for auxiliary circuit and microprocessor supply. Panel with machine controls. Power supply: 400/3/50. CONTROL SYSTEM MP.COM microprocessor system with graphic display for control and monitor of operating and alarms status. The system includes: - Voltage free contact for remote general alarm. - Main components hour-meter. - Non-volatile Flash memory for data storage. - Menu with protection password. - LAN connection. WARNING For DX units it is necessary to provide the refrigerant and the lubricant oil charge for the connection pipes and for the remote air cooled condenser. RC GROUP S.p.A. T_NXTMTR_0511_IT R407C 7

OPTIONAL ACCESSORIES Remote air cooled condensers with axial fans series TEAM MATE MR (version DX). 2-way motorized valve with proportional control (0 10V) for condensing control and emergency manual control (version DW). Electronic expansion valve. Solenoid valve on the liquid line (DX version - for remote condenser connection with refrigerant line longer than 10m). Compressor capacitor for power factor - cosϕ 0,9. Phase sequence control relay for compressor. Compressor soundproof cap for a noise reduction of about 3 db(a). Washable air filter with F5 efficiency. Unit floor stand with height adjusting rubber holders. It is not possible to match the unit floor stand with plenum installed under the machine. Condensate drain kit including pump with activation float and 10 linear meters long discharge pipe. The optional is supplied in mounting kit. Sandwich panels with interposed mattress in soundproof material. Blind frontal panel. The accessory allows the intake air from the bottom of the machine. Unit base noise insulation with special bottom panel. Differential pressure switch on the air side for clogged filters alarm signal. Loss of air flow alarm. Underfloor water alarm through sensor to be placed on the floor. Additional underfloor water sensor kit. Temperature sensor on air delivery. Non-return air damper driven by electric servomotor for installation on the machine air delivery. Air distribution plenum with double row adjustable grilles on three sides. Air distribution plenum with double row adjustable grilles on front side and noise absorption partitions. Plenum with F6/F7/F9 efficiency filters on air delivery. Plenum with noise absorption partitions on air delivery. MP.COM microprocessor control accessories: - MP3000 Touch Screen graphic display. - Remote terminal - Clock card for alarms date and time displaying and storing. - Line current indication. - Line voltage indication. - Serial port RCcom, MBUS/JBUS - Serial port LON - Serial port BACnet for Ethernet SNMP TCP/IP - Serial port BACnet for MS/TP - Serial port for GSM modem - Data logger for the memorization of the intervened alarms. - Additional module with the following inlets / outlets: INLETS o External alarm o Smoke / Fire alarm o Cooling enabling o Heating enabling OUTLETS o External alarm 2 o General alarm 3 - Driver for the additional module. WARNING RC GROUP reserves the right to accept the matching of the optional installed on the machine. 8 RC GROUP S.p.A. T_NXTMTR_0511_GB R407C

TECHNICAL DATA - NEXT MTR DX MODEL 007 Z1 009 Z1 011 Z1 013 Z1 015 Z1 S S S S S SIZE H2 H2 H2 H3 H3 COOLING CAPACITY (1) Total kw 6,6 8,7 9,8 11,3 14,4 Sensible kw 6,6 8,7 9,8 11,3 14,4 Compressors power input kw 1,5 1,8 2,2 2,7 3,3 Compressors operating current A 2,8 3,4 4,2 5,0 6,1 SUPPLY FANS n. 1 1 1 1 1 Air flow m 3 /h 2300 3000 3300 4000 5500 Nominal external static pressure Pa 50 50 50 50 50 Max external static pressure Pa 625 530 480 600 640 Power input (2) kw 0,12 0,22 0,27 0,29 0,64 Max power input kw 1,0 1,0 1,0 2,7 2,7 Operating current (2) A 0,26 0,48 0,60 0,45 1,00 Max operating current (FLA) A 2,2 2,2 2,2 4,30 4,30 COMPRESSORS scroll scroll scroll scroll scroll Quantity n. 1 1 1 1 1 Max current A 4,2 5,1 6,3 7,0 10,0 Starting current A 24 32 40 46 50 Capacity steps n. Modulating Modulating Modulating Modulating Modulating AIR FILTERS n. 1 1 1 1 1 Efficiency G4 G4 G4 G4 G4 REFRIGERANT R407C R407C R407C R407C R407C Refrigerant charge (3) kg 5,4 5,4 5,4 6,8 6,8 Gas circuits n. 1 1 1 1 1 POWER SUPPLY V/Ph/Hz 400/3/50+N 400/3/50+N 400/3/50+N 400/3/50+N 400/3/50+N ENERGY EFFICIENCY INDEXES EER Energy Efficiency Ratio (4) kw/kw 3,75 3,70 3,45 3,38 3,31 SOUND LEVEL ISO 3744 (5) On air delivery db(a) 54,5 59,3 61,1 59,0 65,3 On air intake db(a) 54,4 54,8 55,1 55,9 57,1 DIMENSIONS Length mm 785 785 785 1085 1085 Width mm 650 650 650 750 750 Height mm 1925 1925 1925 1925 1925 NET WEIGHT kg 235 238 244 295 305 REMOTE CONDENSER (6) Quantity n. 1 1 1 1 1 TEAM MATE STD series Mod. M.10 M.18 M.18 M.18 M.22 HOT GAS REHEATING SYSTEM Modulating Modulating Modulating Modulating Modulating Heating capacity kw 7,7 8,4 9,0 10,6 11,9 ELECTRIC HEATER Capacity kw 5,1 5,1 5,1 6,0 6,0 Operating current (OA) A 7,4 7,4 7,4 8,6 8,6 Capacity steps n. 3 3 3 3 3 HUMIDIFIER Steam capacity kg/h 3 3 3 3 3 Power input kw 2,3 2,3 2,3 2,3 2,3 Operating current (OA) A 3,2 3,2 3,2 3,2 3,2 Max operating current (FLA) A 4,5 4,5 4,5 4,5 4,5 REFRIGERANT CONNECTIONS Gas delivery ODS Ø 16 16 16 18 18 Liquid return ODS Ø 12 12 12 16 16 CONNECTIONS ISO 228/1-G Humidifier filling F Ø 3/4" 3/4" 3/4" 3/4" 3/4" Condensate discharge rubber pipe F Ø 1/2" 1/2" 1/2" 1/2" 1/2" THE COOLING CAPACITY DOES NOT CONSIDER THE SUPPLY FAN MOTOR THERMAL LOAD 1. Characteristics referred to entering air at 24 C-50%RH; 35 C ambient temperature. 2. Corresponding to the nominal external static pressure 3. Unit refrigerant charge. Remote condenser, connections pipes and optional are excluded. 4. The Energy Efficiency Index consider also the remote air cooled condenser as shown in the table. 5. Noise level at 1 meter in free field (external static pressure 50 Pa) 6. For matching to other remote air cooled condensers please refer to RC WORLD selection program RC GROUP S.p.A. T_NXTMTR_0511_IT R407C 9

TECHNICAL DATA - NEXT MTR DW MODEL 007 Z1 009 Z1 011 Z1 013 Z1 015 Z1 S S S S S SIZE H2 H2 H2 H3 H3 COOLING CAPACITY (1) Total kw 7,0 8,9 10,3 12,3 15,3 Sensible kw 7,0 8,9 10,1 12,3 15,3 Compressors power input kw 1,2 1,6 1,9 2,2 2,6 Compressors operating current A 2,5 3,2 3,9 4,4 5,4 Condenser water flow rate m 3 /h 1,2 1,5 1,8 2,1 2,6 Condenser pressure drop kpa 19 24 23 21 15 SUPPLY FANS n. 1 1 1 1 1 Air flow m 3 /h 2300 3000 3300 4000 5500 Nominal external static pressure Pa 50 50 50 50 50 Max external static pressure Pa 625 530 480 600 640 Power input (2) kw 0,12 0,22 0,27 0,29 0,64 Max power input kw 1,0 1,0 1,0 2,7 2,7 Operating current (2) A 0,26 0,48 0,60 0,45 1,00 Max operating current (FLA) A 2,2 2,2 2,2 4,30 4,30 COMPRESSORS Scroll Scroll Scroll Scroll Scroll Quantity n. 1 1 1 1 1 Max current A 4,2 5,1 6,3 7,0 10,0 Starting current A 24 32 40 46 50 Capacity steps n. Modulating Modulating Modulating Modulating Modulating WATER COOLED CONDENSER n. 1 1 1 1 1 Water volume l 0,8 0,9 1,0 1,3 1,4 Max water flow rate m 3 /h 0,6 0,8 1,0 1,1 1,4 AIR FILTERS n. 1 1 1 1 1 Efficiency G4 G4 G4 G4 G4 REFRIGERANT R407C R407C R407C R407C R407C Refrigerant charge (3) kg 5,8 5,8 5,8 7,5 7,5 Gas circuits n. 1 1 1 1 1 POWER SUPPLY V/Ph/Hz 400/3/50+N 400/3/50+N 400/3/50+N 400/3/50+N 400/3/50+N ENERGY EFFICIENCY INDEXES EER Energy Efficiency Ratio kw/kw 5,22 4,94 4,68 4,88 4,59 SOUND LEVEL ISO 3744 (4) On air delivery db(a) 55,0 59,8 61,6 59,3 65,6 On air intake db(a) 54,4 54,8 55,1 55,9 57,1 DIMENSIONS Length mm 785 785 785 1085 1085 Width mm 650 650 650 750 750 Height mm 1925 1925 1925 1925 1925 NET WEIGHT kg 239 242 249 300 312 HOT GAS REHEATING SYSTEM Modulating Modulating Modulating Modulating Modulating Heating capacity kw 7,7 8,4 9,0 10,6 11,9 ELECTRIC HEATER Capacity kw 5,1 5,1 5,1 6,0 6,0 Operating current (OA) A 7,4 7,4 7,4 8,6 8,6 Capacity steps n. 3 3 3 3 3 HUMIDIFIER Steam capacity kg/h 3 3 3 3 3 Power input kw 2,3 2,3 2,3 2,3 2,3 Operating current (OA) A 3,2 3,2 3,2 3,2 3,2 Max operating current (FLA) A 4,5 4,5 4,5 4,5 4,5 CONNECTIONS ISO 228/1-G Condenser water inlet/outlet M Ø 1 1/4" 1 1/4" 1 1/4" 1 1/4" 1 1/4" Humidifier filling F Ø 3/4" 3/4" 3/4" 3/4" 3/4" Condensate discharge rubber pipe F Ø 1/2" 1/2" 1/2" 1/2" 1/2" THE COOLING CAPACITY DOES NOT CONSIDER THE SUPPLY FAN MOTOR THERMAL LOAD 1. Characteristics referred to entering air at 24 C-50%RH; water to the condenser 30-36 C 2. Corresponding to the nominal external static pressure 3. Unit refrigerant charge optional excluded. 4. Noise level at 1 meter in free field (external static pressure 50 Pa) 10 RC GROUP S.p.A. T_NXTMTR_0511_GB R407C

WORKING LOGIC The control of temperature and humidity conditions, with very small tolerances, are obtained with a proportional working logic of the system which provides continuous and uninterrupted operation of the compressor (H) (MAN ON set on microprocessor) for the simultaneous production of cooling and heating. Temperature control: During cooling phase the system produce only sensible cooling, without dehumidification This is done by raising the expansion temperature by increasing the fan speed automatically (by 0-10V proportional signal from microprocessor) and by hot gas injection in the evaporating coil (B) though the valve (M) until you cancel the latent component of the cooling produced by the evaporating coil. Any excess of cooling is canceled by the proportional hot gas reheating system (C+I) that uses the hot gas from the compressor to reheating the air flow. The accuracy of the hot gas reheating system is obtained through a proportional valve with continuous control (I) directly driven by 0-10V proportional signal from microprocessor. The excess of condensation heat, not used by the hot gas reheating system, is exhausted by the condenser (U). DX version: remote air cooled condenser equipped with axial fans and modulating condensing control system. Condensers are also available with centrifugal fans. DW version: built-in water cooled condenser equipped with 2-way modulating valve for the water flow control. In case of heating request, primarily using the hot gas reheating system and, if it is not sufficient, the 3 steps electric heaters (D) are activated (in combination with the hot gas reheating system). The steps of the electric heaters are very close and allow a precise temperature control. Humidity control : In case of dehumidification request, the system automatically controls the latent cooling capacity by producing cool with forced dehumidification through a reduction of the supply fan rotation speed (by 0-10V proportional signal from microprocessor) and closing the hot gas injection valve (M). In this way the expansion temperature decrease and consequently the latent cooling component increase. Also in this case any excess of sensible cooling is compensated by the hot gas reheating coli as previously described. The humidification is obtained by the proportional steam humidifier with immersed electrodes (G). The humidifier is oversized compared to the standards used in traditional air conditioners. NOTE : To avoid any potential conflict of the regulation control, the system always has priority on the control of temperature. Only after reaching the temperature set-point the system begins to control the humidity. RC GROUP S.p.A. T_NXTMTR_0511_IT R407C 11

NEXT MTR DX WORKING DIAGRAM F E D G I L C B N M A H O U R R P Q R R R S T A B C D E F G H I L Air filters Evaporating coil Hot gas re-heating coil Electric heaters Steam distributor Supply fan Steam humidifier Compressor Hot gas re-heating 3-way valve Check valve M N O P Q R S T U Hot gas injection valve Balancing valve Expansion valve Liquid indicator Refrigerant filter Manual valve Safety valve Liquid receiver Remote air cooled condenser 12 RC GROUP S.p.A. T_NXTMTR_0511_GB R407C

NEXT MTR DW WORKING DIAGRAM F E D G I L C B N M A H O U P Q V R S T A B C D E F G H I L Air filters Evaporating coil Hot gas re-heating coil Electric heaters Steam distributor Supply fan Steam humidifier Compressor Hot gas re-heating 3-way valve Check valve M N O P Q R S T U V Hot gas injection valve Balancing valve Expansion valve Liquid indicator Refrigerant filter Manual valve Safety valve Liquid receiver Built-in water cooled condenser 2-way motorized valve for condensing control water flow RC GROUP S.p.A. T_NXTMTR_0511_IT R407C 13

BASIC PARAMETERS FOR THE NEXT MTR The compressor must be set MANUAL ON. Here's an example of the restrictive temperature / humidity parameters setting : 14 RC GROUP S.p.A. T_NXTMTR_0511_GB R407C

RC GROUP S.p.A. T_NXTMTR_0511_IT R407C 15

16 RC GROUP S.p.A. T_NXTMTR_0511_GB R407C

ELECTRICAL DATA MAXIMUM ELECTRICAL ABSORPTION CALCULATION This chapter has the aim to explain the calculation of the maximum absorbed current by the unit (A), corresponding to extreme working conditions. Example in cooling mode for unit NEXT MTR DX 007 P1 S H2 COOLING (1) - Main fans (FLA) A 2.2 + - Compressor (FLA) A 4.2 + - Electric heaters (OA) A 7.4 = Absorbed current A 13.8 COOLING (2) - Main fans (FLA) A 2.2 + - Compressor (FLA) A 4.2 + - Humidifier (FLA) A 4.5 = Absorbed current A 10.9 HEATING (3) - Main fans (FLA) A 2.2 + - Electric heaters (OA) A 7.4 + - Humidifier (FLA) A 4.5 = Absorbed current A 14.1 The HEATING (3) working condition corresponds to the unit maximum electric absorption. IMPORTANT For the fans, the current nominal values have been considered equal to the data plate values. For this reason, the nominal current and the data plate current are the same. Actually, the real absorbed current is normally lower than the data plate value. These values depend on the unit working conditions and on the type of control of the plant. RC GROUP S.p.A. T_NXTMTR_0511_IT R407C 17

MP.COM: MICROPROCESSOR CONTROL SYSTEM The MP.COM microprocessor control system is equipped with 8 keys terminal and back lighted graphic display on which all information in different languages or easily identifiable symbols are displayed. The system disposes of a flash memory that preserves the information even in absence of power supply. M P. C O M g r a p h i c i n t e r f a c e 13:35 - S - nn - 21/01/07 C 22.4 %53rH % 1 2 1 2 3 4 5 6 7 8 KEYBOARD FUNCTIONS KEY 1 KEY 2 KEY 3 KEY 4 KEY 5 KEY 6 KEY 7 KEY 8 Switches on/off the unit. Stops the alarm acoustical signal and displays the intervened alarm. Accedes to the parameters of possible units connected in LAN network. LAN connection with 3 wires without additional accessories. It is possible to connect in network different capacity units and with different number of compressors. Home key displays the main screen. Accedes to control and visualization menus as: - Unit working status - Set-points - Alarms reset (protected by password) - Service parameters setting (protected by password) - Intervened alarms history - Setting for main components manual operation (protected by password) - Date and time setting - Setting of communication system for SMS messages dispatch Scrolls the pages inside each menu and decreases the displayed value Scrolls the pages inside each menu and increases the displayed value Shifts the cursor inside each menu and confirms a parameter insertion REMOTE CONTROLS/ALARMS INLETS 1 External enabling 2 Cooling enabling 3 Smoke/Fire alarm 4 Temperature set-point compensation (optional) OUTLETS 1 General alarm 1 deviating contact 2 General alarm 2 programmable deviating contact (optional) 3 General alarm 3 - programmable deviating contact (optional) 4 Clogged filters alarm (optional) controls/alarms for remotization voltage free controls/alarms for remotization 18 RC GROUP S.p.A. T_NXTMTR_0511_GB R407C

OPTIONAL ACCESSORIES REMOTE AIR COOLED CONDENSER Remote air cooled condenser series TEAM MATE with horizontal air flow, from coil to fan. The machines are made with weather resistant materials and suitable for outdoor installation. Design, assembly and test as per the Company Quality Assurance program in full compliance with ISO 9001. RC Group has been the first Italian company in its segment to get the ISO 9001 in October 13 th, 1991 with certificate ICIM 0018. The machines are in full compliance with European Norms 2006/42CE, 2006/95CE, 2004/108CE, 97/23CE and subsequent amendments. AVAILABLE VERSIONS The TEAM MATE series is available in 3 versions: TEAM MATE STD - No air flow and sound level reduction TEAM MATE LNO Air flow reduction at 85% with consequent sound level reduction. TEAM MATE ELN Air flow reduction at 70% with further sound level reduction. MAIN COMPONENTS FRAMEWORK Base, self supporting frame and panelling in steel plate with protective surfaces treatment in compliance with UNI ISO 9227/ASTMB117 and ISO 7253, and painted with epoxy powders. Colour: RAL 9002 FANS SECTION Axial fans with sickle-shaped blades, fan guard and optimized for low noise levels. External rotor electric motor with stepless variable speed for condensing pressure control. IP54 enclosure class. CONDENSING COIL Heat exchanger coil with internally corrugated copper tubes and high efficiency aluminium fins, specifically developed to provide high heat transfer and lower pressure drops. The combination of two factors, special tubes and fins, allow to optimally combine the following aspects: - Maximum capacity relative to the size of the exchanger. - Minimum charge of refrigerant. - Reduction of the air flow required for the heat exchange. Frame in galvanized steel. REFRIGERANT CIRCUIT Valves on gas and liquid line for coupling to refrigerant pipe. The condenser is supplied with nitrogen seal. ELECTRICAL PANEL In accordance with EN60204-1 norms, suitable for outdoor installation, IP54 enclosure class, complete with: Terminals for 230/1/50 power supply (from network). Terminals for 0 10V signal for condensing control system (connect to indoor machine). Terminals for alarm signal (connect to indoor machine). Fans speed regulator for condensing control. OPTIONAL ACCESSORY Support legs for vertical air flow. RC GROUP S.p.A. T_NXTMTR_0511_IT R407C 19

TECHNICAL DATA TEAM MATE DXA STD MODEL M 10 M 18 M 22 AXIAL FANS n. 1 1 1 Air flow m³/h 3400 4400 5600 Max power input kw 0,19 0,35 0,40 Max operating current (FLA) A 0,86 2,00 2,20 SOUND PRESSURE LEVEL (1) db(a) 57,0 59,0 58,0 TEAM MATE DXA LNO MODEL M.10 M.18 M.22 AXIAL FANS n. 1 1 1 Air flow m³/h 2890 3740 4760 Max power input kw 0,16 0,3 0,34 Max operating current (FLA) A 0,73 1,7 1,87 SOUND PRESSURE LEVEL (1) db(a) 54,2 55,7 55,7 TEAM MATE DXA ELN MODEL M.10 M.18 M.22 AXIAL FANS n. 1 1 1 Air flow m³/h 2380 3080 3920 Max power input kw 0,13 0,25 0,28 Max operating current (FLA) A 0,6 1,4 1,54 SOUND PRESSURE LEVEL (1) db(a) 50,8 52,3 52,3 COMMON DATA POWER SUPPLY V/ph/Hz 230/1/50 230/1/50 230/1/50 REFRIGERANT CHARGE (2) kg 9,9 9,9 10,6 DIMENSIONS Version with horizontal air flow Length mm 855 855 1155 Width mm 482 482 482 Height mm 726 726 726 Version with vertical air flow Length mm 855 855 1155 Width mm 786 786 786 Height mm 750 750 750 NET WEIGHT kg 31 31 47 1. Sound pressure level [Lp] 1m far according to ISO EN 3744. 2. The condenser is supplied with nitrogen seal. For the refrigerant charge consider, in addition to the these value, even the refrigerant pipes for the connection to the indoor machine and lubricant oil in 10% ratio of charged refrigerant. 20 RC GROUP S.p.A. T_NXTMTR_0511_GB R407C

OPTIONAL ACCESSORIES - CONDENSATE DISCHARGE PUMP A plastic case contains the vertical type pump, the water tank with float plus safety switch and hydraulic and electric connection. Together the pump 10 linear meters anti-crushing plastic discharge spiral tube is supplied The optional has to be installed as shown in the documentation delivered together with the unit. Wiring includes power supply and an alarm, displayed on microprocessor, that includes motor pump thermal protection and tank overflow. The condensate discharge pump operation is fully automatic. WARNING The optional is supplied in mounting kit. TECHNICAL DATA Power supply 230/1/50 Power input W 75 Absorbed current A 0,5 Capacity tank l 2 Discharge pipe Ø mm 10/16 Maximum water flow l/h 300 Minimum water flow l/h 3 Discharge head - with min. water flow mh 2O 4,5 - with max. water flow mh 2O 0,3 CONDENSATE DISCHARGE PUMP Condensate discharge 3/8 Condensate inlet 28 RC GROUP S.p.A. T_NXTMTR_0511_IT R407C 21

OPTIONAL ACCESSORIES - FLOOR STAND It is not possible to match the unit floor stand with plenum installed under the machine. For a correct installation of the air conditioner we suggest you to utilize a gasket between the floor stand and the unit base. The floor stand is available in 3 different heights. FLOOR STAND H 82 63 63 A SIZE H2 H3 A mm 691 791 MODEL 230 330 390 H minimum height mm 255 355 400 H maximum height mm 350 450 510 22 RC GROUP S.p.A. T_NXTMTR_0511_GB R407C

OPTIONAL ACCESSORIES - BOTTOM PANEL With this accessory it is possible a noise insulation of the machine base, when the machine is installed directly on particular floor as raised floor, wood floor etc. The accessory includes: Panel in galvanized steel sheet. Noise insulation with special soundproof material. The bottom panel is supplied assembled inside the unit base and does not modify the unit dimensions. BOTTOM PANEL 1 2 1) Air conditioner 2) Air conditioner base 3) Bottom panel 4) Insulation with special sound soundproof material 4 3 OPTIONAL ACCESSORIES - SANDWICH PANEL The accessory includes: External part as standard panel. Internal part in galvanized steel sheet. Noise insulation with special soundproof material. The accessory increase the unit weight: Size H2 H3 Weight increasing kg 43 54 (1) 1. Add this value to the total unit weight RC GROUP S.p.A. T_NXTMTR_0511_IT R407C 23

OPTIONAL ACCESSORIES - NON RETURN MOTORIZED DAMPER Accessory to install on units air delivery and it can be matched to air conditioner, plenums and floor stand. The damper is provided with connecting flange for the air delivery duct. For a correct installation we suggest you to utilize a gasket between the damper and the unit or the plenum. NON RETURN MOTORIZED DAMPER Size H2 H3 A mm 785 1085 B mm 650 750 C mm 450 750 D mm 510 610 E mm 214 214 F mm 73 73 G mm 48 48 Weight (1) kg 23 30 1. Add this value to the total unit weight 1) Non return damper 2) Gasket 3) Air conditioner 24 RC GROUP S.p.A. T_NXTMTR_0511_GB R407C

NEXT MTR PLENUM OPTIONAL ACCESSORIES - AIR DELIVERY PLENUM The plenums have same technical characteristics and base dimensions of the machine cabinet. Plenum for ducting Plenum for ducting with F6/F7/F9 efficiency filters Plenum for ducting with noise absorption partitions Size H2 H3 Plenum (1) kg 21 20 Plenum with filters (1) kg 27 27 Plenum with partitions (1) kg 27 30 Plenum with grille for frontal air distribution into the room and noise absorption partitions Size H2 H3 Plenum with grilles (1) kg 26 28 Plenum with grilles and partitions (1) kg 30 37 Plenum with grilles on 3 sides, for direct air distribution into the room. Size H2 H3 Plenum with grilles (1) kg 23 30 1. Add this value to the total unit weight FOR ALL PLENUMS Size H2 H3 A mm 490 490 RC GROUP S.p.A. T_NXTMTR_0511_IT R407C 25

OPTIONAL ACCESSORIES MP.COM REMOTE TERMINAL The remote terminal is supplied in kit and includes a painted steel sheet box contained the Terminal and the T card for the connection to the unit. The box has a wall mounting predisposition. With the remote terminal it is possible the remote management of all the units connected in LAN network (max 10 units). MP.COM REMOTE TERMINAL 1) LCD display with keyboard 2) Rubber fairlead 16MV 3) T card for connection 4) Wall mounting box 26 RC GROUP S.p.A. T_NXTMTR_0511_GB R407C

MACHINE DRAWINGS Dimensions in mm NEXT MTR H2 RC GROUP S.p.A. T_NXTMTR_0511_IT R407C 27

MACHINE DRAWINGS Dimensions in mm NEXT MTR H3 28 RC GROUP S.p.A. T_NXTMTR_0511_GB R407C

TYPICAL INSTALLATION DIAGRAMS FOR DIRECT EXPANSION MACHINES WITH REMOTE AIR COOLED CONDENSER 1) Air conditioner 2) Remote air cooled condenser 3) Gas discharge line 4) Liquid line 5) Trap. Foresee a trap every 5m of the rising pipe. 6) Additional liquid receiver external to the conditioner with valves and safety valve. Suggested part in the following cases: a) refrigerant line longer than 25-30m b) plant operation with ambient temperature lower than 0 C with refrigerant line any length Install the liquid receiver close to the air conditioner. 7) Solenoid valve of the liquid line. It is an optional accessory of the air conditioner for refrigeration plants with refrigerant pipe longer than 10m THIS DIAGRAM APPLIES TO EACH REFRIGERANT CIRCUIT OF THE UNIT. WARNING It is necessary to provide the refrigerant charge for the connection pipes and for the remote air cooled condenser. Charge refrigerant in the suitable quantity and lubricant oil in 10% ratio of charged refrigerant. Lubricant oil must be the same type as the charged one as shown on the compressor plate. RC GROUP S.p.A. T_NXTMTR_0511_IT R407C 29

TYPICAL INSTALLATION DIAGRAMS FOR DIRECT EXPANSION MACHINES WITH REMOTE AIR COOLED CONDENSER 1) Air conditioner 2) Remote air cooled condenser 3) Gas discharge line 4) Liquid line 5) Non - return valve. 6) Additional liquid receiver external to the conditioner with valves and safety valve. Install the liquid receiver close to the air conditioner. 7) Solenoid valve of the liquid line. It is an optional accessory of the air conditioner for refrigeration plants with refrigerant pipe longer than 10m THIS DIAGRAM APPLIES TO EACH REFRIGERANT CIRCUIT OF THE UNIT. WARNING It is necessary to provide the refrigerant charge for the connection pipes and for the remote air cooled condenser. Charge refrigerant in the suitable quantity and lubricant oil in 10% ratio of charged refrigerant. Lubricant oil must be the same type as the charged one as shown on the compressor plate. 30 RC GROUP S.p.A. T_NXTMTR_0511_GB R407C

NEXT MTR WITH DUCT EXAMPLE FOR MACHINES NOISE EMISSION CALCULATION Lp A = Air intake Over catalogue value Lp B = Air delivery Over catalogue value The point B do not influence the point A NEXT MTR WITH PLENUM ON AIR DELIVERY Lp A = Air intake Over catalogue value Lp B = Air delivery Over catalogue value plenum noise reduction LpA LpC Lp A+B = 10 log10 (10 10 +10 10 ) NEXT MTR WITH DUCT AND PLENUM ON AIR DELIVERY Blind front panel Lp A = Radiated Over catalogue value Lp B = Air delivery Over catalogue value Lp C = Lp A + 6dB(A) plenum noise reduction LpA LpC Lp A+C = 10 log10 (10 10 +10 10 ) The point B do not influence the point A+C NEXT MTR WITH DUCT AND PLENUM ON AIR SUCTION Lp A = Radiated Over catalogue value Lp B = Air delivery Over catalogue value Lp C = Lp D = Lp A + 6 db(a) plenum noise reduction The points B, C and D do not influence the point A Blind front panel IMPORTANT The declared noise levels are intended in free field conditions. The noise pressure level of an installed unit is affected by the room acoustic characteristics. Please consider an average noise increase of +4/+6 db(a). RC GROUP S.p.A. T_NXTMTR_0511_IT R407C 31

The continuous improvement of products may imply changes in the data shown in this catalogue. RC GROUP S.p.A. Via Roma, 5 27010 Valle Salimbene (PV), Italy www.rcgroup.it Tel. +39 (0) 382 433 811 Fax +39 (0) 382 587 148 T_NXTMTR_0511_GB