Thermostatic Bath Shower Mixer. Without shower kit.

Similar documents
Pegler Yorkshire reserve the right to change specifications. 10 Year Guarantee Luxury Taps and Mixers

Komo Thermostatic Bar Shower. Excluding Shower Kit

Code Description Dimensions 4P1061 RUNE CP MONOBLOC DUALFLOW SINK MIXER see image. Operating Pressure (bar)

Basin Tap. Time delay maximum 2 seconds

Dual Control Thermostatic Bath and Shower Mixer

Francis Pegler Memento Single Sequential Exposed Thermostatic Shower

TRV & Lockshield Pack Angle Pattern Thermostatic Radiator Valve Vertical or horizontal mounting with (367 CPLS) matching lockshield

Straight pattern thermostatic radiator valve vertical or horizontal mounting with (368T CPDLS) matching drain off lockshield

Artisan Thermostatic Bath Filler

Prism Thermostatic Recessed Shower with Integral 2 Outlet Diverter

Varsity Concealed Shower System

Airfield Industrial Estate Hixon Staffordshire ST18 0PF

CONCEALED THERMOSTATIC SHOWER MIXER VALVE installation & aftercare instruction

Installation Instructions Flute Tap Range

X62 Tap Range. Please keep these instructions for future reference

Thermostatic Concealed Shower Valve

Parenzo Range. Basin Mixer, Bath Filler & Bath Shower Mixer. Assembly instructions

Mio Concealed Shower Mixing Valve MI40010CP

Kiko Bath Shower Mixing Valve KK90015CP

Inta City Shower Mixing Valve CT20010CP

Single Lever Pull out Kitchen Tap

Deluge Shower Mixing Valve 10045CP

Enzo and Enzo Deluxe Safe Touch Thermostatic Shower EN10031CP & EN10035CP

Decade Tap Range. Installation Instructions & User Guide. Please keep these instructions for future reference and request of replacement parts

Intatherm Safe Touch Basin Tap IT1008CP

Twin & Triple Exposed Thermostatic Shower Valve Installation & Operating Guide

Plus Bath Shower Mixing Valve CP and PL30020CP

Thermostatic Bar Valves

Deluge Concealed Shower Mixing Valve DL40010CP

Concealed Twin & Triple Thermostatic Shower Valve with Diverter. Installation & Operating Guide

Installation Instructions and User Guide. Thermostatic Recessed Dual Control Shower Valve. Models covered: CAS SHCVO C, COB SHCVO C, ORB SHCVO C,

Technical Specifications: Your product has a high quality finish and should be treated with care to preserve the visible surfaces.

Puro Mini Dual Control Shower Mixer PU90010CP

Installation, Operating and Maintenance Guide

Inta City Concealed Shower Mixing Valve CT80010CP

Infra Red Thermostatic Wall Mixer

Male elbow, copper x BSP taper male thread

Installation and User Guide

Capri Tap Range. Installation Instructions & User Guide. Please keep these instructions for future reference and request of replacement parts

Installation Instructions and User Guide Thermostatic Recessed Dual Control Shower Valve

Kinetic. Logic. Astin. THERMOSTATIC INLINE CONTROL SHOWER VALVES Installation & aftercare instructions. Please retain for future reference

Enzo Concealed Shower Mixing Valve

Union coupling. copper x copper. Cone joint to BS 1010.

Telo Shower Mixing Valve TL10016CP

Smile Tap Range. Installation Instructions & User Guide. Please keep these instructions for future reference and request of replacement parts

Kiko Concealed Shower Mixing Valve KK80010CP

Thermostatic exposed shower valve and bath/shower mixer systems Installation guide

Pisa Tap Range. Installation Instructions & User Guide. Please keep these instructions for future reference and request of replacement parts

Singulier Spout Tube Basin Mixer Installation and User Guide

INTA ION MODERN BAR / BATH SHOWER MIXER CP

Oblo Basin and Bidet Monobloc Installation and User Guide

Nero Tap Range. Fitting Instructions & Contents List

TREVI BLEND SINGLE LEVER SHOWER VALVES. INSTALLER After installation pass to user for future reference

INTADUO THERMOSTATIC BATH/SHOWER MIXER

Mira Reflex Thermostatic Bar Valve

Cube Triplel Concealed Thermostatic Shower. Telephone Product Specification. Cleaning

Enzo Safe Touch Thermostatic Shower EZ10010CP & EZ10014CP

Installation Instructions & Maintenance Guide 6 Refit Nuts (19) and tighten.

These instructions must be left with the user.

Blitz Tap Range. Installation Instructions & User Guide. Please keep these instructions for future reference and request of replacement parts

Installation Instructions and User Guide

Aquamixa. Thermo. Thermostatic shower valve with manual bath fill

Dual Control Concealed & Exposed Thermostatic Shower Valve

EcoStyle Dual Concealed Thermostatic Shower. Telephone Product Specification. Cleaning

INSTALLATION MANUAL Wolfen Hob Mounted Sensor Tap with Internal Solenoid. Installation Details Warranty

Enzo Safe Touch Thermostatic Shower EZ20011CP & EZ20012CP

Thermostatic bar mixer valve with adjustable head Installation guide

Blueberry Kitchen Sink Tap

Installation Instructions and User Guide. Thermostatic Recessed Dual Control Shower Valve with Integral Diverter

Dream DCV. Thermostatic Dual control mixer valve range. Installation guide

Installation Instructions and User Guide Thermostatic Recessed Dual Control Shower Valve with Integral Diverter

Floor Standing Bath Shower Mixer. Fitting instructions. Please keep these instructions for future reference and request of replacement parts.

Self-help Temperature Adjustment

Installation Instructions Thermostatic Bar Shower Valve ALTO ECOTHERM

Beeline Monobloc Kitchen Mixer Tap

GENERAL FITTING GUIDE THERMOSTATIC BAR SHOWER MIXER with RIGID RISER KIT

ANTI-SCALD THERMOSTATIC MIXING VALVES PUTTING YOU IN CONTROL

Aqueous Thermostatic Surface Mounted Bar Shower Valve With Fast Fit Connections

Mira Atom ERD Thermostatic Bar Valve

Target Monobloc Kitchen Mixer Chrome

257mm 181mm mm

MemoirsStately3HoleBasin Mixer Installation and User Guide

Cinnamon Kitchen Sink Tap

Installation, Operating and Maintenance Guide

Monza Easyfit Kitchen Sink Mixer

EXPOSED BATH SHOWER MIXER INSTRUCTION MANUAL W INST 300. Please note: Tap heads shown is for illustration purposes only.

Thermostatic Bar Valve

Quartz. Thermo. Concealed shower valve with adjustable head. Quartz Thermo installation guide page 1

Installation Instructions and User Guide Thermostatic Recessed Dual Control Shower Valve

Pear Kitchen Sink Tap

Wave. BATH SHOWER MIXER MONOBLOC With Kit Deck Mounted

MIDAS. Installation instructions 110/220

Atmos Energy. Thermostatic Concentric Mixer Valve with Overhead. Fitting Instructions

Minimalist Bottom Outlet Thermostatic Bar Shower. Telephone Product Specification

Eden Bath Shower Mixer

In-line thermostatic mixing valves

Installation Instructions and User Guide

Ambassador. Installation guide & user instructions. Please ensure that this document is handed to the user after installation is completed

Thermostatic mixing valves. Pegler Yorkshire

THERMOSTATIC SHOWER VALVE

Transcription:

Thermostatic Bath Shower Mixer. Without shower kit. 555QT Size Pattern No. Pack 1 Qty Pack 2 Qty Code Barcode Price ( ) ex 555QT Code A B C D E F Pegler Yorkshire reserve the right to change specifications 5 Year Guarantee Luxury Taps and Mixers Pegler Yorkshire Customcare 5 Year Guarantee - Terms and Conditions Product are subject to a 5 year guarantee that is between Pegler Yorkshire and the final purchaser of the product. The guarantee is subject to proof of purchase being supplied. This guarantee does not affect any statutory rights the consumer may have in law. The guarantee covers manufacturing or material defects and does not cover parts subject to normal wear and tear. Finishes other than chrome are covered for a period of 3 years only and the guarantee on the finish is subject to the cleaning instructions being followed. The guarantee is not applicable where the product is fitted contrary to the conditions in the fitting instructions. Abusive behaviour and accidental damage to the product are not covered by this guarantee. The extent of this liability is limited to the cost of the replacement of the defective item and not to fitting or consequential damages. Description Minimum Operating Pressure (bar) Maximum Cold Working Pressure (bar) Maximum Hot Working Pressure (bar) 555QT Thermostatic Bath Shower Mixer 0.1 bar 6.0 bar at temperatures up to 85oC 6.0 bar at temperatures up to 85oC Care To maintain the surface finish, simply wipe occasionally with a mild detergent on a soft damp cloth. Dry, using a soft cloth. Never use abrasive cleaners or chemical household cleaners and avoid contact with concentrated bleach. Maintenance No regular maintenance is required for this product.

In case of complete replacement Pegler recommend service valves should be fitted to the supply inlets. For any further help or replacement parts please contact the Service Support Team on 0800 1560050. Regulations It is important to ensure that the water supplies to your taps and mixers are connected in accordance with the water regulations (WRAS) requirements and good plumbing practice. It is Pegler s recommendation and good plumbing practice that the supplies of hot and cold water to the bath mixer should be at equal (balanced) pressures in order to provide a consistent flow. Supplies should be from a common source, either mains or tank fed. If supplies are not equal pressures then non return valves (801 check valves), (not supplied) should be fitted in each inlet supply line. The outlet of the fitting must be at least 25mm above the spill over level of the bath. It is recommended that in all new and refurbishment installations a thermostatic mixing valve should be installed on the hot inlet supply. The thermostatic mixing valve is designed to prevent scolding when using the hot water supply. 555QT 1 1 HD98CP DIVERTER HANDLE 854261 5013866073526 01/01/1900 To 29.95 2 DV21CP DIVERTER ASSEMBLY 2 854260 5013866073519 01/01/1900 To 23.87 3 ON8CP OUTLET NIPPLE 3 854259 5013866073502 01/01/1900 To 21.87 4 SP9 SPRING 854258 5013866073496 01/01/1900 To 2.25 4 5 HKH31 CPT CD QT HEADWORK COLD 3/4 5 HKC30 CPT CD QT HEADWORK HOT 3/4 5 814045 5013866056420 01/01/1900 To 814044 5013866056413 01/01/1900 To 51.74 51.74 6 SLW2 SEALING WASHER 854263 5013866073540 01/01/1900 To 0.74 6 7 3/4 BN 915 BACKNUT 817072 5013866023361 01/01/1900 To 3.83 7 8 IN13CP INDICE 854253 5013866073441 01/01/1900 To 22.52 8 10 HD97CP HANDLE 854254 5013866073458 01/01/1900 To 94.90 10 12 HK89 HEADWORK CARTRIDGE 854257 5013866073489 01/01/1900 To 168.98 12 Description Code Barcode Date From Date To 13 Price ( ) ex 13 FS24CP FLOW STRAIGHTNER ASSEMBLY 811573 5013866054877 01/01/1900 To 24.42

15 FI5 FILTER & RESTRICTOR PACK 15 854262 5013866073533 01/01/1900 To 47.04 16 HD19CP 3/4 LEVER HANDLE CW INDICES CP 16 814077 5013866056444 01/01/1900 To 73.00 17 17 INH1 INDICE HOT 814001 5013866056314 01/01/1900 To 2.03 17 INC1 INDICE COLD 814002 5013866056321 01/01/1900 To 2.03 Pegler Yorkshire Group Ltd, St Catherine's Ave, Doncaster, S Yorkshire, DN4 8DF Telephone: Phone +44 (0) 844 243 4400 Fax: +44 (0) 844 243 9870 Website: www.pegleryorkshire.co.uk Registered office : Pegler Yorkshire Group Ltd, St Catherine's Ave, Doncaster, S Yorkshire, DN4 8DF Company no : 00401507

IMPORTANT Before making water supply connections ensure that hot supply is connected to the left hand tailpipe and the cold supply to the right tailpipe, when viewed from the front. If supplies are the opposite way round, these will have to be crossed before connecting the mixing valve. IMPORTANT It is a requirement that all TMV2 approved valves shall be tested against the original set temperature results once a year. When testing is due the following performance checks shall be carried out. IN - SERVICE TEST 1. Measure the mixed water temperature at the outlet. 2. Carry out the cold fail-safe shut off test by isolating the cold water supply to the TMV, wait for five seconds if water is still flowing check that the temperature is below 46 ºC. 3. If there is no significant change to the set outlet temperature (±2 ºC or less change from the original settings) and the fail-safe shut off is functioning, then the valve is working correctly and no further service work is required. Re-setting maximum temperature. Re-setting the maximum temperature is not advisable. However, in situations where it is required, please follow these instructions. Remove plate (A) inserting a pin in the hole behind the knob. Loosen the screw (B) remove the knob (C). Then using allen key provided, position down centre of spindle (D) locate on the internal screw and turn. Rotating screw anti-clockwise will increase temperature, rotating clockwise will decrease temperature. IMPORTANT The mixed water temperature at the terminal fitting must never exceed 46 ºC THERMOSTATIC CARTRIDGE CALIBRATION. Check the recommended temperature by placing handle (C) back on spindle and turn anti-clockwise until stop is reached. Once satisfied, screw back in place (B) and insert the plate (A). OPERATION The BTS is supplied factory set maximum at 46ºC For showering applications we recommend a temperature no greater than 41ºC. It is essential that when using the shower function of the BTS the outlet temperature is reduced to prevent injury. Operating the Fully Thermostatic Bath and Shower Mixer. The purchase of this fully thermostatic Bath and Shower Mixer gives you complete confidence that you can both bathe and shower in perfect safety. Operating the central easy grip handle fully controls both the bath and shower water temperature ensuring that safety is at heart of this product. WHEN IN OPERATION OF EITHER BATH OR SHOWER BOTH HOT AND COLD HANDLES ARE TO BE TURNED ON TO OPERATE THE THERMOSTATIC CONTROL. Failure to not turn on both handles will not allow water to flow correctly as designed, due to the in built safety feature. The default operation is always the bath and then diverter used at the rear of the fitting to change water flow over to the shower. When either option is in use however, the temperature control is then co-ordinated by the central handle. FUNCTION OF THE DIVERTER. Lower the diverter knob (H) and turn clockwise in order to insert the dowel (I) in the housing on the body (L). Now the water will pass through the outlet to shower (F).Return the diverter back to its position by reversing the above instructions. This operates on pressure of 0.2 and above. PLEASE NOTE HOWEVER UPON USING THE MANUAL OVERRIDE IT IS ALWAYS RECOMMENDED TO DIVERT BACK TO BATH AFTER USE, SO UNFORESEEN DISCHARGE FROM THE SHOWER HEAD UPON NEXT USAGE IS NOT HAZARDOUS TO THE POTENTIAL BATHER. Care & Maintenance To maintain the surface finishes, simply wipe occasionally with a mild detergent on soft damp cloth. Dry using soft cloth, never use abrasive cleaners or chemical household cleaners, avoid contact with concentrated bleach. Your Guide to the installation, care and maintenance of Leger & Performa QT Leger L555 Thermostatic Bath / Shower Mixer Performa 555 Thermostatic Bath / Shower Mixer NOTE Any TMV that has been adjusted or serviced must be re-commissioned and re-tested in accordance with the manufacturers' instructions. CAUTION The following temperatures are recommended for all premises and should never exceed 46 ºC Application Recommended Set Mixed Water Temperature for bath fill. 44 C for shower applications 41 C 5 YEAR GUARANTEE Pegler taps and Mixers are guaranteed for 5 years from the date of purchase. Pegler products are manufactured to the highest standards and should require little or no maintenance. In the unlikely event of any spare part requirements, please visit our website : www.pegler.co.uk, contact your nearest stockist or the Pegler Technical Office on telephone 0870 1200285 L555 Thermostatic Bath / Shower Mixer 555 Thermostatic Bath / Shower Mixer for wash basin applications 41 C for bidet applications 38 C Pegler Limited, St. Catherine s Avenue, Doncaster, South Yorkshire. DN4 8DF Telephone: 01302 560560 Fax: 01302 560109 PERFORMA

PEGLER WATER REGULATIONS REQUIREMENTS The installation of thermostatic mixing valves must comply with the requirements of the Water Supply (Water Fittings) Regulations 1999. It is important to ensure that the water supplies to your taps and mixers are connected in accordance with the water regulations (WRAS) requirements and good plumbing practice. It is Pegler s recommendation and good plumbing practice that the supplies of hot and cold water to the bath/shower mixer should be at equal (balanced) pressures in order to provide a consistent flow. Supplies should be from a common source, either mains or tank fed. If supplies are not equal pressures then non return valves should be fitted (supplied) Pegler supply two non return valves, two filters, two retaining clips and three flow regulators, any combination of these can be used in conjunction with two brass housings - also supplied. These products have been designed to function on all types of water systems. Should excessive flow be experienced, then it may be necessary to install a Pressure reducing valve (PRV). It is also our recommendation and good plumbing practice that full bore servicing valves (PB300) should be installed upstream in the water supply line. This should be done so as close as is practicable to the water supply inlets of the thermostatic mixing valve. The use of isolating valves is always good plumbing practise, for future servicing and maintenance. NOTE If a pump is to be installed to boost gravity supplies, please refer to the pump manufactures instructions. WORKING PRESSURES Pegler fittings have been designed to function under the following conditions: Minimum bath supply pressure 0.1 bar Minimum shower diverter operation without manual fixing 0.2 bar The valve has been designated for use as a Low Pressure valve in-line with BSEN 1287: 1999 NOTE Valves that operate outside these conditions cannot be guaranteed to work /operate correctly by the scheme as a type two valve. Max Pressure Differential 5:1 Minimum Temperature (Hot/Mixed) = 10ºC - Differential TABLE 1: CONDITIONS FOR NORMAL USE High Pressure Low Pressure BS EN 111 BS EN 1287 Maximum Static Pressure (bar) 10 10 Flow Pressure Hot & Cold (bar) 0.5-5 bar 0.1-1 bar Cold Supply Temperature < 25ºC < 25ºC Hot Supply Temperature 55-65ºC 55-65ºC Pre-Installation Checks When planning the plumbing for your Bath and Shower Mixer installation it is recommended that the hot and cold supplies are independent for gravity fed and pumped systems, and that no other draw off are on the same feed. For unvented and gas heater installations it is preferable that both supplies are the first on the circuit. The hot and cold inlets for your bath and shower mixer are, hot on the left and cold on the right, when viewed from the front of the fitting. Connections MUST be made in this way. Failure to do so is dangerous to the user and could result in irreparable damage to the internal valve mechanism. Always ensure the installation of the valve is in such a position that maintenance of the fitting and its valves and the commissioning and the testing of the TMV can be undertaken. COMMISSIONING INSTRUCTIONS Before Commissioning this or any other TMV you must ensure the following: 1. The designation of the thermostatic mixing valve matches the application. 2. The supply pressures are within the valves operating range. 3. The supply temperatures are within the valves operating range. 4. Isolating valves (and strainers preferred) are provided MOUNTING THE FULLY THERMOSTATIC BATH AND SHOWER MIXER. a) Remove bath panel to gain access to securing the plumbing connections. b) Ensure water is turned off and has been fully drained. c) Disconnect both supplies. d) Unscrew backnuts and remove existing fitting or taps. e) Clean tap platform before installing your new Bath and Shower Mixer. f) Place sealing gasket on top platform in-line with existing holes. g) Locate Bath and Shower Mixer through holes and secure to tap platform with brass backnuts provided. Using the additional sealing washers beneath the ware. OUTLET CONNECTIONS The outlet for the shower is 1/2 BSP male thread. This will accept standard shower hoses screwed directly onto the outlet. Refer to the Francis Pegler luxury showers brochure for a comprehensive choice of Waterfall shower kits. All sliding rail kits come with a hose retaining ring to ensure that the handset cannot be dropped into the water creating a possible back syphonage problem. PIPE CONNECTIONS IMPORTANT. Before making any inlet pipe connections all supplies MUST be thoroughly flushed to remove any debris. Failure to do so could result in damage or low flow from the mixing valve. It is a requirement of Byelaw 55 of the Water Fittings Byelaw Scheme that this function is undertaken. Before making any pipe connections to supplies, flow regulators may be fitted at this stage if required. NOTE The coloured regulator ends signify the flow. Pink = 15.0 litres a minute. White = 8.0 litres a minute. Use of flow regulator Cold inlet Hot inlet Gravity Both Supplies No No Mains Cold/Gravity Hot Yes/Pink No Unvented High Pressure Yes/White Yes/White Pumped both supplies No No Gas Instantaneous Heaters Yes/White Yes/White Mains Cold/Pumped Hot Yes/White Yes/White Gravity Cold/Pumped Hot No Yes/White NOTE When connecting the mixing valve to the mains supply it is recommended that the non return valves are fitted on both inlets. This is also imperative if the supply of water is unbalanced on the two inlets. THERMOSTATIC VALVE: MAINTENANCE and/or CARTRIDGE REPLACEMENT. It is recommended that the thermostatic control is serviced annually as required by the TMV2 scheme. Remove the plate (A) inserting a pin in the hole behind the knob. Loosen the screw (B) remove the knob (C). Use a good fitting spanner to unscrew the thermostatic cartridge (D) and remove it from the body of the tap. Descale with vinegar and lubricate the gaskets with heat-resistant grease. Re-assemble the whole by reversing the above proceedure. FITTING THE FLOW REGULATOR AND CHECK VALVES. In all installations the minimum fitment must be, in order: 1. Two check valves first-installed with spring loaded central valve allowing for the flow of water into the mixer 2. Next the two flat filters-the installation of these is important to ensure that any chance of debris entering the thermostatic elements is removed. The lack of installation of these could cause the unit to malfunction and make void any warranty on the product. 3. Finally to hold the above items in position it is equally important that the retaining clips are used. These are to be located in the grooves machined on the inside of the tails by squeezing the clip and locating into position Installations defined where the flow regulator are required, then this should be in place of the check valves. (The Pegler flow regulators combines a check valve and comes complete with a brass housing). Insert the appropriate regulator into the brass carrier. This should be done with star shaped coloured end pushed into the brass housing first. Push until o ring forms a seal on internal bore of the brass housing. Next insert this assembly into the tail of the tap - star shaped coloured end first. Following this continue with stages 2 and 3 above.