E3M-V. Mark Sensor. Applications

Similar documents
Color Mark Sensor. Sensing gdsa distance Spot diameter e. Possible to switch between vertical or horizontal connection using the M12 rotary connector.

10 to 30 VDC Diffuse 40 mm ±10 mm NPN and PNP, switch-selectable

pre-wired E3FA-TP11-F2 2M E3FB-TP11-F2 2M

Compact, Photoelectric Sensor with Built-in Amplifier and Teaching Function. Mark Sensor with Stainless Steel Housing

Transparent Object (PET Bottle) Detection Compact Photoelectric Sensor

E3FA PHOTOELECTRIC SENSORS

E3FA PHOTOELECTRIC SENSORS

Transparent Object (PET Bottle) Detection Compact Photoelectric Sensor

E3FA PHOTOELECTRIC SENSORS

Ultrasonic Proximity Sensor

Ultrasonic Proximity Sensor

F3UV. Monitoring output state of UV (ultraviolet light)/illumination light source. Ultraviolet power monitor/illumination monitor.

Transparent Object (PET Bottle) Detection Compact Photoelectric Sensor

Ultrasonic Reflective Sensor

E3FA/E3RA/E3FB/E3RB. Application specific models. Limited-reflective types suitable for detecting transparant film to shiny, mirror film.

Ultrasonic Reflective Sensor

Communications None RS-232C RS-422* RS-485* BCD Transmission output*/** (4 to 20 ma) E5AX- E5AX- L(M)A02 L(M)A03

High Reliability Of Fiber Optic Amplifier For Convenient Mounting

Small diffuse reflective and convergent reflective type BYD50-DDT BYD50-DDT-U 1 BYD100-DDT BYD3M-TDT BYD3M-TDT-P

Reliable Detection of Transparent Objects

TEMPERATURE CONTROLLER

onlinecomponents.com

enproteko.com Specifications Ratings Item voltage to 24 VAC 5/6 Hz 24 VAC 5/6 Hz or 24 VDC Allowable voltage Characteristics 85% to 11% of power suppl

Communications* None RS-232C RS-422 RS-485 BCD Transmission output** (4 to 20 ma)

Adjustable Range Reflective Photoelectric Sensor. General terms and conditions... F-17 Glossary of terms / General precautions...p.1359~ / P.

panasonic.net/id/pidsx/global Gentle start-up switches in accordance with ergonomics Reduces load on hands and fingers

SENSORS. S8 Series HIGHLIGHTS APPLICATIONS. Phone: Fax: Web: -

E2K-L. Liquid Level Sensor That Is Unaffected by the Color of the Pipe or Liquid. Liquid Level Sensor. Ordering Information

Adjustable Range Reflective Photoelectric Sensor. panasonic.net/id/pidsx/global

Class 1 laser beam sensor safe for your eyes

Digital Panel Meter K3TL. Ordering Information. Low-cost, High-quality Digital Thermometer with Built-in Microcomputer. Accessories (Order Separately)

Background suppression photo sensors

Class 1 laser beam sensor safe for your eyes

Class 1 laser beam sensor safe for your eyes

Optical system Beam shape Sensing distance Resolution*1 Model Diffuse reflective Spot beam 40±10 mm 2 µm ZX-LD40. Line beam 40±10 mm 2 µm ZX-LD40L

APS-S/M Series. Polycarbonate Resin Square Type, 2-wire/3-wire DC System. Type. Proximity Sensor. Features

Series Description. Features. Available Models. Specifications. Specifications for All Models. Specifications for Standard Models

Mark and Colour Sensors

EE-SX91. Meeting Customer Needs with Compact Sensors that Mount with M3 Screws

BSF4-AH80. Flameproof Type Light Curtain Type 4. Globally-compliant flameproof structure. Ample protective height 1,595 mm 62.

culus and CE Marked for all applicable directives Operating Environment Operating Temperature [C (F)]

K7L-U/K7L-UD. Liquid Leakage Sensor Amplifiers for Long-distance Wiring. Enables longdistance. up to 400 m.

5 m pre-wired 2NC/1NO F3S-TGR-NLMX m pre-wired 2NC/1NO F3S-TGR-NLMX m pre-wired 2NC/1NO F3S-TGR-NBMX-21-05

RFID Non-contact switches are designed to monitor hinged, sliding or removable guard doors. RFID technology provides increased tamper resistance.

Communications type RS-232C RS-422 RS-485 E5AJ-A2H02 E5EJ-A2H02

Scanning Laser Range Finder Smart-URG mini UST-10LN Specification

Flameproof Type Light Curtain Type 4

Appearance and sensing characteristic Specification (temperature range) Model 10 to 70 C ES1B. 2 mm 20 mm 40 mm 60 mm. 40 dia. 60 dia.

Selection guide...p.457~ SF-C13...P.663~ Glossary of terms... P.1549~ General precautions... P panasonic.net/id/pidsx/global

Leuze electronic. Dimensioned drawing. Electrical connection. Accessories: 150m ISO 9001

Ionizer Basic Fan Type ZJ-FA20. High-speed, High cost performance Ionization

Model Number Structure

E3FA PHOTOELECTRIC SENSORS

Reliable Detection of Transparent Objects

Retroreflective sensor with polarization filter

Retro-reflective Sensing range: 0mm to 2000mm

Emitter. Emitting circuit. Control circuit. Check. Monitoring section (CPU) Emitting element failure. Emitting circuit failure

XUM0APSAM8 photo-electric sensor - XUM - multi - Sn 0..10m VDC - M8

Digital Heater Element Burnout Detector K8AC-H

Cat. N. Cat. N (s) 1. DESCRIPTION - USE 3. OVERALL DIMENSIONS. Technology : 4. PREPARATION - CONNECTION 2. PRODUCT RANGE

Doc. No. IZ -OMK0015 OPERATION MANUAL PRODUCT NAME: MODEL:

Laser Collimated Beam Sensor

Selectable 2sec., 7sec., 15sec. (selectable by holding time setting switch)

panasonic.net/id/pidsx/global Lights up when conditions are normal (and at incipient liquid leak detection) Use as a warning Sensor

General terms and conditions... F-7 General precautions... P panasonic.net/id/pidsx/global. Use as a warning. Sensor. Emergency stop.

FACTORY AUTOMATION SENSE WITH SIMPLICITY AND CONFIDENCE PHOTOELECTRIC FIBER AMPLIFIER SU18 AND SU19 SERIES

2 General Application Photoelectric Sensors

Tubular Optical Sensors. BOS S18 Economical Series Applications. Description. Features

Item Symbol Rating Unit Power supply V CC 12.0 VDC Output voltage V OUT 3.0 VDC

Original operating instructions Photoelectric safety sensors (safety light curtain / safety light grid) Protected area width (range) 0...

2 General Application Photoelectric Sensors

Interchangeable thermistor (THE types) Output Contact E5CS-R1KJX-F E5CS-R1PX-F E5CS-R1GX-F Voltage E5CS-Q1KJX-F E5CS-Q1PX-F E5CS-Q1GX-F

E3NX-MA. Smart Fiber Amplifier Units. Downsize control panels using the Omron dualchannel. Ordering Information

/ / 2018

Retroreflective sensor with polarization filter

Series Temperature Controller Instruction Sheet

2 General Application Photoelectric Sensors

XUBLAPCNL2 photo-electric sensor - XUB - thru beam - laser - Sn 100m VDC - cable 2m

FT10Aseries. Self-check feature provided. Fiber type / CMD. Within detecting distance 40 m

Vacuum unit ideal for controlling large flow rates Vacuum unit VSQ/VSQP series

Analog Room Pressure Monitor RPC Series

Solid-State Contactor Specifications

AnyWireASLINK System Products Guide

AUR300C, AUR350C. Advanced Ultraviolet Burner Controller

Advanced Ultraviolet Burner Controller

2 General Application Photoelectric Sensors

XUX0AKSAM12 photo-electric sensor - XUX - multi - Sn 0..40m VDC - M12

The World's Longest-distance * Detection

275HVD NON-CONTACT, HIGH VOLTAGE DETECTOR DETECTOR DE ALTA TENSIÓN SIN CONTACTO

Sintrol Snifter A1+ Manual. Version 1.2.2

COMPLIANT MANAGER. Installation Manual. Model name: BMS-CM1280TLE BMS-CM1280FTLE. Save These Instructions! ENGLISH

Table of Contents. Page Quick Set-up Instructions 1. Theory of Operation 2. Specifications 3. TM 1003W Controls and Connections 4

Automatic Self-Adjusting General Purpose Sensor

Snifter. User Manual. Distributor

General Specifications

ICS Regent. Fire Detector Input Modules PD-6032 (T3419)

Plug-in Base, Long Range Sensor E3B2

Online data sheet WS/WE45-P260S01 W45 PRODUCT PORTFOLIO

Table of Contents. 1. Mounting Tips... 2

16 mm. Ionizer Nozzle type. Ion balance ±10 v. Slim design: Thickness dimension 16 mm RoHS compliant. Series IZN10

Transcription:

Mark Sensor Detects laminated or light-dispersing objects in stable operation without being influenced by mirror reflection. Double indication of the detection level and threshold level allows easy grasp of the operating status and easy adjustment. Automatically sets to the optimum threshold level while sensing objects are being conveyed and incorporates an auto-teaching function that discriminates between the mark and background and turns ON when the mark is detected. IP67 watertight construction with M12 rotary connector High response speed of 50 s and half the size of OMRON's conventional models. Applications Dependably Detects Marks on Laminated Sheets The coaxial optical system ensures a long sensing distance and stable sensing characteristics over a wide angle range, even for objects that are distance-fluctuating or leaning at an angle, or for laminated objects with marks, which conventional models have difficulty in detecting Auto-Teaching An auto-teaching function automatically sets the threshold value upon a Remote Control input while the workpiece is moving. There is no need to position the mark at the optical spot. A-133

Ordering Information Sensors Shape Connection method Setting distance Spot diameter Model NPN output PNP output 1 x 4 mm G11 G16 Connector type 1 4 x 1 mm G21 G26 10+3 mm 1 x 4 mm G12 G17 Pre-wired 4 x 1 mm G22 G27 1. Possible to switch between vertical or horizontal connection using the M12 rotary connector Mounting Brackets Shape Model Quantity Remarks E39-L131 1 E39-L132 1 For rear mounting Sensor I/O Connectors Shape Type Cord type Model Single-end connector (Straight) Single-end connector (L-shaped) 2 m XS2F-D421-D80-A 5 m XS2F-D421-G80-A 4-wire cord 2 m XS2F-D422-D80-A 5 m XS2F-D422-G80-A A-134 Standard Photoelectric Sensors

Specifications Ratings/Characteristics Item G11 G12 G21 G22 G16 G17 G26 G27 Sensing distance 10±3 mm Spot size (W x H) 1 x 4 mm 4 x 1 mm 1 x 4 mm 4 x 1 mm Light source (wavelength) Green LED (525 nm) Power supply voltage 10 to 30 VDC, ripple (p-p) 10% max. Current consumption 100 ma max. Load power supply voltage: 30 VDC max. Load power supply voltage: 30 VDC max. Load current: 100 ma max. Load current: 100 ma max. Control output Remote control input 1 Remote control output 1 (Residual voltage: 1.2 V max.) NPN open collector output type ON: Short-circuited to 0 or 1.5 V max. (with a flow current of 1 ma max.) OFF: Open or VCC - 1.5 V to VCC (with a leakage current of 0.1 ma max.) Load power supply voltage: 30 VDC max. Load current: 100 ma max. (Residual voltage: 1.2 V max.) NPN open collector output type (Residual voltage: 2 V max.) PNP open collector output type ON: VCC - 1.5 V to VCC (with an absorption current of 3 ma max.) OFF: Open or 1.5 V max. (with a leakage of 0.1 ma max.) Load power supply voltage: 30 VDC max. Load current: 100 ma max. (Residual voltage: 2 V max.) PNP open collector output type Bank selection Two banks selectable. Available for remote control only. (Refer to Remote Control Function.) Circuit protection Protection from reversed power supply connection and load short-circuit Response time ON: 50 µs max. OFF: 70 µs max. Ambient illumination Incandescent lamp: 3,000 lx max. (on receiver lens) Sunlight: 10,000 lx max. Ambient temperature Operating: -20 C to 55 C/Storage: -30 C to 70 C (with no icing) Ambient humidity Operating: 35% to 85%/Storage: 35% to 95 C (with no condensation) Insulation resistance 20 M min. (at 500 VDC) Dielectric strength 1,000 VAC, 50/60Hz, 1 min. Vibration resistance 2 Destruction: 10 to 55 Hz, 1-mm double amplitude or 150 m/s2 for 2 hrs each in X, Y, and Z directions Shock resistance 3 Destruction: 500 m/s2 3 times each in X, Y, and Z directions Degree of protection IEC60529 IP67 (with protective cover) Connection method Connector Pre-wired Connector Pre-wired Connector Pre-wired Connector Pre-wired Weight with package box Approx. 100 g Material Case: Polybutylene terephthalate Lens: Acrylic (PMMA) Others Instruction manual 1. Remote controll input and answer-back output share the same signal line. 2. The Sensor withstands 0.75 mm double amplitude or 100 m/s² if the mounting bracket is attached to the sensor 3. The Sensor withstands 300 m/s² if the mounting bracket is attached to the sensor. A-135

Incidence (%) Engineering Data Sensing Distance vs. Incident Characteristics (Typical) G1 Angle vs. Incident Characteristics (X Direction) G1/VG2 Angle vs. Incident Characteristics (Y Direction) G1/VG2 Incidence (%) Incidence (%) Incidence (%) Distance (mm) Angle ( ) Angle ( ) Color Sensing Capacity G Differences in Incident by Color White Red Yellow red Yellow Green yellow Green Blue green Blue Purple Red purple Black White Red Yellow red Yellow Yellow green Green Blue green Blue Purple Red purple Black X X X X X X White Red Yellow red Yellow Yellow green Green Blue green Blue Purple Red purple Black Color : Detectable : Detectable but unstable X: Not detectable Technical Guide Glossy Sensing Objects Incline the Sensor to detect glossy objects so that the Sensor will not be influenced by the mirror reflection of light and to ensure the stable sensing operation of the. 5 to 155 5 to 155 Standard Sensing Object (Color vs. Munsell) Japan Color Enterprises Standard Color Card 230 11 standard colors Munsell color notation White N9.5 Red 4R, 4.5/12.0 Yellow red 4YR, 6.0/11.5 Yellow 5Y, 8.5/11.0 Yellow green 3GY, 6.5/10.0 Green 3G, 6.5/9.0 Blue green 5BG, 4.5/10.0 Blue 3PB, 5.0/10.0 Purple 7P, 5.0/10.0 Red purple 6RP, 4.5/12.5 Black N2.0 Sensing object Sensing object A-136 Standard Photoelectric Sensors

Nomenclature Operation Indicator (Orange) Lit when the output is ON. Detection Level Indicators (Green) Displays the detection level. Indicators (Red) Displays the threshold level. Mode Selector Selects the mode. SET Button Used for teaching and threshold adjustments. UP/DOWN Selector Increases the threshold value when set to UP. Decreases the threshold value when set to DOWN. Operation Output Circuits NPN (G11, G12, G21, G22) Detection level indicators (green, 8 levels) Operation indicator (orange) inidcators (red, 13 levels) Main circuit 1 Brown Load (See note.) White 2 Remote control input /Answer-back output Black 4 Blue 3 Control output Load 100 ma max. 10 to 30 VDC Connector Pin Arrangement PNP (G16, G17, G26, G27) Detection level indicators (green, 8 levels) inidcators (red, 13 levels) 1 4 Brown Black Control output Operation indicator (orange) Main circuit 2 3 Remote control input /Answer-back output White Blue Load (See note.) Load 10 to 30 VDC A-137

Adjustments Adjustment Steps 1. Install, wire, and turn ON the Photomicrosensor. 2. Perform teaching (mark registration). Refer to Mark Registration (Teaching). Mark Registration (Teaching) Refer to the following for ideal teaching. The base has a color pattern. The mark and base are clearly different in color. Application The base has no color pattern. The mark and base are slightly different in color. The base has no color pattern. Remote teaching with no positioning is desired. One-point teaching Two-point teaching Auto-teaching The default level is set and the output is ON when the mark is detected. Refer to the following for each teaching method. Remote one- or twopoint teaching is possible. Refer to Remote Control Function. One-point Teaching 1 Set the mode selector to TEACH. 2 Locate the mark to the sensing position and press the SET button. Then all the red threshold indicators are ON. Sensor The threshold level is set between the color of the mark and base. The output is ON when the mark is detected. The threshold level is set between color of the mark and base. The output is ON when the mark (i.e., the color with shorter passing time) is detected. 3. Make fine adjustments of the threshold level if necessary. Refer to Level Adjustments on page A-139. 4. Check that the mode selector is set to RUN. Two-point Teaching 1 Set the mode selector to TEACH. 2 Locate the mark to the sensing position and press the SET button. All the red threshold indicators will turn ON. Sensor Base 3 If teaching is successfull, move the mark and press the SET button at the base. If teaching is successfull, all the green detection level indicators are ON. If teaching is unsuccessfull, all the red threshold level indicator flash. Sensor Mark Base Mark Push Push Red threshold indicators are ON. Green detection level indicators are ON. Teaching is OK Base Mark Push All the red threshold level indicators will flash if there is no difference in incident. Red threshold indicators are ON. 3 Set the mode selector to RUN. The output will be ON whenever the set mark is detected. Note: By teaching on the base, reversed output as shown above (base: ON, mark: OFF) can be obtained. Teaching is NG 4 If teaching is successful, set the mode selector to RUN to complete the teaching operation. If teaching is unsuccessful, restart from the above step 2. Note: Follow the above steps so that the output will be turned ON whenever the mark is detected. By taking the opposite steps, the output will be turned OFF whenever the mark is detected and turned ON whenever the base is detected. A-138 Standard Photoelectric Sensors

Auto-teaching 1. Check that the mode selector is set to either RUN or ADJUST. 2. Input a 0.9-s pulse signal into the remote control I/O terminal. 1 3. Auto-teaching starts when the mark is moved. When the mark passes six times, auto-teaching completes. If teaching is successful, answer-back output from the remote control I/O terminal will turn ON for 0.3 s. If teaching is unsuccessful, no answer-back signal will be output. Readjust using two-point teaching. (Teaching will be unsuccessful if there is no difference in incident between the mark and base.) 4. If the answer-back signal is ON, the whole teaching operation will be completed. The output will be turned ON whenever the mark (i.e., the color with shorter passing time) is detected. Auto-teaching Teaching starts Teaching completes and detection starts Remote control input/ Answer-back output Auto-teaching Answer-back Time Incident Mark (shorter passing time): Output ON Optimal threshold level set Base: Output OFF Dummy sampling (1st mark) Sampling (5th mark) Time Example of Connection to Programmable Controller Sensor Remote control I/O I/O Unit Output Input Programmable Controller Note: Be sure to connect the to the Programmable Controller as shown above. Precautions when Using Automatic Teaching Incorrect discrimination may be caused by automatic teaching in the following cases. Use one-point or two-point teaching in such cases. Color patterns exist in the base. Sensing objects change their positions. Sensing objects have protrusions or surface level differences. Level Adjustments It is possible to make fine adjustments of the threshold level after teaching. Such fine adjustments can be made remotely as well. Refer to Remote control Function (Bank Selection, Mark Registration, and Adjustments) on page A-140. 1 Set the mode selector to ADJUST Select the upper or lower threshold selector. Whenever the SET button is pressed, the threshold level will move. Two indicators will be lit together when the threshold level is an even level. Upper threshold limit The threshold level increases. Press 2 The threshold level decreases. Lower threshold limit indicators level 3 After setting the level, set the mode selector to RUN. 1. Make sure that the input tolerance of each pulse is within ±0.1 s. A-139

Detection Level Indicator Detection Level Indicator The control output of the will be turned ON if the detection level exceeds the threshold level. The indication of the detection level varies with the teaching method. One-point Teaching The upper and lower threshold values are set on the basis of the mark and the detection level indicators indicate the degree of color conformity to the mark's color. Detection level Output OFF value Output ON Mark Detection level indicators Operation indicator Control Signals No. Control signal Function 1 Bank 1 is selected (operation indicator OFF in TEACH mode) 2 Bank 2 is selected (operation indicator ON in TEACH mode) 3 Auto-teaching 4 Two-point teaching (1st and 2nd) 5 One-point teaching (or input for 1.5 s min.) value Output OFF 6 level 1 is selected. value Two-point or Auto-teaching A single threshold value is set between the mark (registered first) and the base (registered next). The detection level indicators indicate the tolerance between the mark and base. 7 level 3 is selected. 8 level 5 is selected. Detection level Detection level indicators Operation indicator 9 level 7 is selected. 10 level 9 is selected. Mark Output ON value Output OFF Base 11 level 11 is selected. 12 level 13 is selected. value Remote control Function (Bank Selection, Mark Registration, and Adjustments) Under Run Mode or Adjust Mode The input of any of the signals listed in the following table into the remote control I/O terminal allows remote control of the. When the signal is accepted, answer-back output will be turned ON for 0.3 s. Only in the case of one-point teaching, however, can the signal be manually input, provided that the input is ON for 1.5 s or more. Timing Chart Note: The input error of each signal pulse must be within ± 0.1 s Ladder Program Example Control signals are input by a ladder program as shown below. TIM000, TIM001, and TIM002 set values Answer-back output: ON only when the process completes normally. 2.5 s min. Remote control I/O 2.0 s Input signal 0.3 s Next input signal Input: 00000 Output: 00100 Others: IR bits Sensor operation Input discrimination (1.8 s) Setting change Detection restarts Note: If Signals are sent continuously, make sure that there is an interval of 2.5 s between signal inputs as shown above. A-140 Standard Photoelectric Sensors

Dimensions Note: All units are in millimeters unless otherwise indicated. Mark Sensors Connector Models Eight detection level indicators Seven level threshold indicators Operation indicator M2.6 Optical axis 10-dia. lens Two, 4.5-dia. mounting holes M2.6 nut Mounting Holes Two, M4 M12 Connector Pre-Wired Models 47.8 45 Two, 4.5 dia. mounting holes 67.8 25 29 43 Vinyl-insulated round cable with three conductors, 6 dia. (17 x 0.16 dia.); standard length: 2 m A-141

Accessories (Order Separately) Mounting Brackets E39-L131 Two, 4.2 dia. 905+15 Material: Stainless steel (SUS304) E39-L132 4.2 dia. 905+15 Material: Stainless steel (SUS304) A-142 Standard Photoelectric Sensors

Sensor I/O Connectors Single-end Connector (Straight Model) XS2F-D421-D80-A (L=2 m) XS2F-D421-G80-A (L=5 m) 5 dia. 14.9 dia. 6 dia. Single-end Connector (L-shaped Model) XS2F-D422-D80-A (L=2 m) XS2F-D422-G80-A (L=5 m) 6 dia. 5 dia. Installation Sensor I/O Connector Pin No. Wire colors Brown White Blue Black DC/AC Note: 1.pin No. 2 is not used. 2.For details, refer to the Sensor I/O Connectors Catalog (X065) Classification DC Wire color Connector pin No. Use Brown 1 Power supply (+V) --- 2 --- Blue 3 Power supply (0V) Black 4 Output A-143

Precautions Observe the following precautions to ensure safety. Do not use the Sensor in locations subject to flammable or explosive gases. Do not use the Sensor in water or conductive solution. Do not disassemble, repair, or modify the Sensor. Use the Sensor under proper power supply specifications such as the use of AC or DC power supply. Do not apply any voltage or current exceeding the rated level. Be careful with the power supply polarities and wire correctly. Connect the loads correctly. Do not short-circuit both ends of loads. Correct Use Installation Power Reset Time Since the is ready to detect objects from 100 ms max. after the is turned ON, operate the remaining devices 100 ms after the Sensor is turned ON. If power is supplied to the and the load independently, be sure to turn on the first. Power OFF The may output a single pulse when the control power supply is turned OFF. If the is connected to a timer or counter to which power is supplied from an independent power supply, the E3M- V will be more likely to output a single pulse when the control power supply is turned OFF. Therefore, supply power to the timer or counter from the same power supply for the. Power Supply Type No full-wave or half-wave rectified power supplies can be connected to the. Power Supply Connection Be sure to ground the FG (frame ground) and G (ground) terminals if a switching regulator is connected to the, otherwise the E3M- V may malfunction due to the switching noise of the switching regulator. Wiring Cable The cable can be extended up to 100 m provided that the thickness of the cable is 0.3 mm2 minimum. Repeated Cable Bending The cable must not be bent repeatedly. High-tension Lines The power supply lines of the Sensor must not be wired alongside power lines or high-tension lines in the same conduit, otherwise the Sensor may become damaged or malfunction due to induction noise that may be generated from the power lines or high-tension lines. Route the lines separately or in a single conduit. Cable Pulling Force Do not pull cables with pulling forces exceeding 50N. Mounting Screw Tightening Make sure that the casing is tightened to a maximum torque of 1.2 N o m. Mounting Direction When Sensors are mounted to face each other, make sure to adjust the optical axes so that the Sensors will not be mutually interfered. Others EEPROM Write Error An EEPROM error may result if power supply to the Sensor fails or the Sensor is influenced by static noise, in which case the threshold level indicators will flash. Perform the teaching and threshold level setting of the again. M12 Metal Connector Make sure to connect or disconnect the metal connector after turning off the. Make sure to hold the connector cover when connecting or disconnecting the metal connector. Tighten the metal connector securely by hand. Do not use any tool, such as pliers, otherwise the metal connector may be damaged. If the metal connector is not tightened securely, the metal connector may be disconnected by vibration and the proper degree of protection of the may not be maintained. ALL DIMENSIONS SHOWN ARE IN MILLIMETERS. To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527. Cat. No. E280-E2-01A-X In the interest of product improvement, specifications are subject to change without notice. A-144 Standard Photoelectric Sensors