REVERSIBLE R744 (CO 2 ) HEAT PUMPS APPLIED IN PUBLIC TRAINS

Similar documents
COMPACT HEAT EXCHANGERS FOR MOBILE CO 2 SYSTEMS

FACT SHEET 9 Large Air-Conditioning (air-to-air)

FACT SHEET 9 Large Air-Conditioning (air-to-air)

PHASE-IN of natural refrigerants. Prof. Dr. Armin Hafner NTNU Norway

Current use of HFCs and HCFCs. Trends, alternatives and climate impact. YEREVAN, Armenia, May 18-19, International Institute of Refrigeration

Brazed Plate Heat Exchanger for CO Applications

HFO-1234yf Performance in a Beverage Cooler

R&D ON HEAT PUMPS WITH NATURAL WORKING FLUIDS IN JAPAN

HFCs or the Old Refrigerants - what is the best Choice?

Environmentally friendly refrigeration systems for industrial use

Chapter 10. Refrigeration and Heat Pump Systems

DTI Kenneth Bank Madsen Global Application Expert Food Retail

A Theoretical investigation on HC Mixtures as Possible Alternatives to R134a in Vapor Compression Refrigeration

Welkom. Optimalisatie CO2 systemen m.b.v. ejecteur

Refrigeration Cycle And Compressor Performance For Various Low GWP Refrigerants

Heat Pump Fluidised Bed Dryer with CO 2 as Refrigerant Measurements of COP and SMER

Sub-Critical Operation of the CO2 Expander/ Compressor

EVALUATION OF ALTERNATIVERS TO R404 THE MOST COMMON REFRIGERANT IN SWEDISH GROCERY STORES

Performance of CO2 Cycles with a Two-Stage Compressor

NATURAL REFRIGERANTS FOR HEAT PUMPS AND AIR-CONDITIONING SYSTEMS. Bernard Thonon Greth

Heat pump supplemental heating system for motor vehicles

Volume 3, Issue 4 (2015) ISSN International Journal of Advance Research and Innovation

DEMONSTRATION OF ADVANCED INTEGRATED HVAC&R SYSTEMS IN A LOBLAWS SUPERMARKET IN CANADA

Comparative Study of Transcritical CO 2 Cycle with and Without Suction Line Heat Exchanger at High Ambienttemperature

Introduction of Transcritical Refrigeration Cycle Utilizing CO2 as Working Fluid

Role of Nano-technology for improving of thermal performances of vapour compression refrigeration system (VCRS): An Overview

Refrigerants & Cooling in renovation buildings

Q. Which hydrocarbons can be used as a refrigerant? The following hydrocarbons can be used as a refrigerant in cooling & heating applications:

Low GWP Refrigerants for Air Conditioning Applications

International New Technology and Refrigerant Symposium

Alternatives in the AC & Chiller Sectors. Sukumar Devotta and Lambert Kuijpers OORG Refrigeration

Transcritical CO2 Bottle Cooler Development

Energy Performance of Low Charge NH3 Systems in Practice. Stefan S. Jensen

An Investigation Into The Influence Of Improved Refrigeration Cycle And Refrigerants On An Energy Efficient Domestic Refrigerator

Large AC units using a variety of low-gwp options

International Journal of Research in Engineering and Innovation Vol-1, Issue-5 (2017), 68-72

Development of R744 Two Stage Compressor for Commercial Heat Pump Water Heater

Thermodynamics I. Refrigeration and Heat Pump Cycles

Ammonia. Background on ammonia as a refrigerant

European Experience in Certification of competence in ODS substitutes: F-gas and Alternative Refrigerants. Pune, 5 th March 2015

Experimental study on automotive cooling and heating air conditioning system using CO 2 as a refrigerant

Experimental Study on Compact Heat Pump System for Clothes Drying Using CO 2 as a Refrigerant. Abstract

compact BOOSTER RACK TRANSCRITICAL CO 2 Cooling capacity LT: from 2 to 130 kw Cooling capacity MT: from 20 to 300 kw

INTERNSHIP REPORT 1/3

DROP-IN EVALUATION OF REFRIGERANT 1234YF IN A RESIDENTIAL INTEGRAL HEAT PUMP WATER HEATER

Design of Divided Condensers for Desiccant Wheel-Assisted Separate Sensible and Latent Cooling AC Systems

Overview of refrigerant alternatives in the air conditioning sector *

Lower GWP Refrigerants Compared to R404A for Economizer Style Compressors

Comparative assessment for drop in replacement of R134a in domestic refrigerator.

Chillers for High Ambient Conditions: What Technologies and Fluids?

Magnetic Refrigeration. Study Case

INTERNSHIP REPORT 1/3

Commercial CO 2 Refrigeration Systems

COMPARATIVE PERFORMANCE ANALYSIS OF EXPERIMENTAL FRIGORIFIC AIR CONDITIONING SYSTEM USING R-134A AND HFO-1234YF AS A REFRIGERANT

Low Global Warming Refrigerants For Commercial Refrigeration Systems

Waste Heat Recovery Analysis of CO 2 Refrigeration Systems

System Design, Commissioning, Operation

Be sustainable while protecting your business

New Refrigerants & Selecting Capital Equipment

PERFORMANCE OF A VERY LOW TEMPERATURE REFRIGERATION SYSTEM OPERATING WITH NATURAL FLUIDS

Commercial CO2 Refrigeration Systems. Guide for Subcritical and Transcritical CO2 Applications

CO 2 AS REFRIGERANT FOR SYSTEMS IN TRANSCRITICAL OPERATION PRINCIPLES AND TECHNOLOGY

A refrigeration system for supermarkets using natural refrigerant CO 2

Subscripts 1-4 States of the given system Comp Compressor Cond Condenser E Evaporator vol Volumetric G Gas L Liquid

Study of R161 Refrigerant for Residential Airconditioning

Honeywell Refrigerant Update

The R-404A Challenge. Commercial Opteon Refrigerant Solutions - The New Industry Standard

Reducing Refrigerant Leakage

A Review on Analysis of Vapour Compression Refrigeration System Using Matrix Heat Exchanger

Menerga Adconair Various solutions one heat recovery system

ETI-Z Series Centrifugal Chiller Applied Low GWP Refrigerant to Contribute to the Prevention of Global Warming

EN aquatech.piovan.com

Modelling of an Integrated Supermarket Refrigeration and Heating System Using Natural Refrigerants

NEW COPPER-BASED HEAT EXCHANGERS FOR R744 REFRIGERANT PART II: SYSTEM DESIGN AND CASE STUDIES

New Case studies on Low GWP alternative refrigerants for HFCs. ABHIJEET KUDVA

ABSTRACT. 2 CanmetENERGY

CO 2. ECO Water Heaters. Energy efficient and environmentally friendly water and space heating. SANYO Air Conditioners. The natural choice.

Actions to Control Emission of HFCs in Japan

EFFECT OF PAG OIL CIRCULATION RATE ON THE HEAT TRANSFER PERFORMANCE OF AIR-COOLED HEAT EXCHANGER IN CARBON DIOXIDE HEAT PUMP SYSTEM

HSPF Calculation of a System Allowing Switching Between a Single-Stage to a Two-Stage Compression System

ANALYSIS OF LGWP ALTERNATIVES FOR SMALL REFRIGERATION (PLUGIN) APPLICATIONS

TRENDS IN RETAIL INDUSTRY REFRIGERATION & REVIEW OF EUROSHOP 2017 EXHIBITION

PERFORMANCE EVALUATION OF CO 2 HEAT PUMP HEATING SYSTEM ABSTRACT 1. INTRODUCTION

An Experiment of Heat Exchanger Produces Hot Water Using Waste Heat Recovery from Air Conditioning

Sanhua accepts the challenge of new low-gwp refrigerants

R-404A Alternative with Low Compressor Discharge Temperature

Thermodynamic analysis of air cycle refrigeration system for Chinese train air conditioning

Performance Comparison of Ejector Expansion Refrigeration Cycle with Throttled Expansion Cycle Using R-170 as Refrigerant

Update on Next Generation Low GWP Refrigerants for Chillers Products. Steve Kujak Director, Next Generation Refrigerant Research

Trends and Perspectives in Supermarket Refrigeration

NUMERICAL SIMULATION OF VAPOUR COMPRESSION REFRIGERATION SYSTEM USING REFRIGERANT R152A, R404A AND R600A

Use Of Ammonia for Air Conditioning Applications

CHAPTER 1 INTRODUCTION

CASE STUDIES OF THERMALLY DRIVEN HEAT PUMP ASSISTED DRYING. Minh Cuong Tran, Jamy Logie, Bruno Vanslambrouck, Martijn van den Broek

Volume 2, Issue 4 (2014) ISSN International Journal of Advance Research and Innovation

Thermodynamics II Chapter 5 Refrigeration

Sustainable Refrigerant Solutions for HVAC-R. Laurent Abbas, Wissam Rached, Brett Van Horn

ENERGY SAVING IN A DOMESTIC SPLIT-TYPE AIR CONDITIONER WITH EVAPORATIVE COOLING SYSTEMS

Experimental Study on Performance Parameters for Refrigerants R22, R410a and R404a at Various Air Outlet Temperatures

THE INSTITUTE OF REFRIGERATION

Transcription:

REVERSIBLE R7 (CO ) HEAT PUMPS APPLIED IN PUBLIC TRAINS ARMIN HAFNER a ØYSTEIN CHRISTENSEN b & PETTER NEKSÅ a (a) SINTEF Energy Research (b) NTNU Norwegian University of Science and Technology Kolbjørn Hejes vei 1A, 75 Trondheim, Norway <Armin.Hafner@sintef.no> ABSTRACT This paper presents opportunity for use of R7 (CO ) as refrigerant in the air conditioning system in public trains. The R7 system shall provide cooling in the summer and heating in the winter. Today 75% of the air conditioning systems in trains use HFC-13a as refrigerant. The GWP of HFC-13a is 11 while R7 is 1(). A replacement from HFC-13a to R7 gives possibilities of large environmental savings. Different technical system solutions of the heat pump are presented, each with its own method of providing cooling and heating. Solution I; changes between cooling and heating mode are performed by changing the direction of the refrigerant flow through the system. Solution II changes between cooling and heating mode are done by changing the configuration of the air streams (movable hatches) through the heat exchangers. In Solution III the refrigerant flow direction and the configurations of the air streams is always the same. The whole heat pump is placed on a turntable unit and the change between cooling and heating is done by rotating the entire heat pump 18. In all the three technical solutions there are separated heat exchangers for fresh and exhaust air. This gives an energy efficient system which recovers heat from the exhaust air. Computer simulation shows that a system solution with one evaporation pressure and one stage compression is problematic for low ambient temperatures; the system must stand temperatures to - C. A system solution with two levels on the evaporation pressure and a two stage compression showed to improves the COP from 1,7 to 3, when the ambient temperature at - C. Norway is a country with cold climate. Weather statistics show that a train which drives in Oslo every day from to 18 throughout a year will need cooling 3% of the time and heating 83% the time. This heating should be done by a heat pump and not with electrical heating as today. Results of the computer simulation shows that the annual energy consumption of heating the train will be reduced by 78 % if the designed R7 heat pump is used in stead of electrical heating. 1. INTRODUCTION Vehicles on the roads are not the only one which contributes to global HFC emissions, as shown in a survey Final Report Maritime, Rail, and Aircraft sector by Schwarz &Rhiemeier (7) In the rolling stock of the railway, tram and metro operators consisted in the EU of 175. units, 5. of them equipped with air conditioning systems. 75 % of these HVACs applied R13a as refrigerant and 5% used HFC-7C. The total charge (stock) of refrigerant in the railway sector is 1.5 tonnes CO - eq. This is % more than in the Maritime sector. However, the HFC (& HCFC) emissions from the Maritime sector are much higher than for the Railway units, mainly due to poor service and high leakage rates of maritime units. The estimated annual leakage rate is around %, even when applying indirect systems % of the refrigerant is lost every year. In the Railway Sector the leakage rate is 5% for the majority of the vehicles

Estimations of the emissions in with a business-as-usual assumption show that the HFC emissions from the railway sector will double to 17 tonnes CO eq while the emissions from the maritime sector will increase to the threefold to 1 11 tonnes CO eq. Morgenstern & Ebinger (8) perform research on future railway vehicle air conditioning systems and how the energy consumption can be reduced. R7 and HFO-13yf are two evaluated refrigerants. If HFO-13yf is applicable in the public transport sector business as usual can be practised, beyond safety issues known technology will be applied. However, concerns are shown about this new fluid due to flammability issues and the deadly toxic decomposition products. Neither are all thermodynamic and technical properties of this refrigerant known, understood nor published. R7 HVAC systems have to stand much higher working pressures (high pressure side ca 8-1 bar). A completely new technology has to be applied, which may result in higher initial costs of the first HVAC units. As commonly known, carbon dioxide applied as working fluid has the advantage that it is natural, environmentally friendly, globally available at low costs and there are no unknown effects which will ban this fluid applied as refrigerant in the future. Annual energy savings compared with conventional R13a system for air conditioning of passenger coaches are measured by Morgenstern & Ebinger, (8). Show results of an experiment were annual energy demands for different HVAC system in railway passenger coaches are compared to an existing R13a system (1%). In this experiment a prototype CO system had lower energy demands (~5%) than an optimized R13a system (~%).. MOBILE HVAC SYSTEM LAYOUT There are many ways to design the HVAC system which are able to perform both heating and cooling, as shown by Hafner (1998; 3). Different system layouts for mobile HVAC systems will be presented and discussed. Solution I. The heat pump system changes from cooling mode to heating mode by reversing the direction of the refrigerant flow through the unit. In this solution the heat exchangers have to be designed to operate both as evaporator and gascooler. (not part of this study) Solution II. The switch between heating and cooling mode is done by redirecting the air stream through the HVAC system. The refrigerant flow inside the heat pump is not re-directed, i.e. it flows in the same direction and the air heat exchangers do not change function from gas cooler to evaporator when the system mode is changed. Solution III. The heat pump is located on a turntable unit and changes from cooling to heating mode are done by rotating the table by 18. The CO always flow in the same direction and the configuration of the different air streams is also similar in the two operating modes. A system design where fresh/ambient and exhaust air is mixed in the first place and then sent to a heat exchanger is not preferable since some of the potential energy/exergy in the exhaust air is lost. Therefore separated evaporators and gas coolers are proposed for fresh and exhaust air. All the system solutions are designed to contain four air to refrigerant heat exchangers, one refrigerant to glycol heat rejecting exchanger, to supply heat to a possible floor heating circuit and an internal suction line heat exchanger. Due to different temperature levels of the inlet, outlet, re-circulated and ambient air, two gas coolers and two evaporators are applied in air ducts of theses HVAC systems. The fresh/ambient air has its temperature level and a defined volume flow rate through the evaporator before entering the passenger compartment and the heat rejecting gascooler which rejects the heat to the ambient during the season when cooling of the compartment is required. The interior / passenger compartment air is already treated and has a temperature level close to the desired compartment temperature, i.e. in cooling mode exhaust air, which leaves the passenger compartment, has most of the time a lower temperature than ambient, which allows for a further temperature reduction of the refrigerant downstream of the first gascooler.

GC 1 GC EV 1 EV Cooling mode (T_ amb > T_ exhaust ) Ambient air Air which exits compartment Ambient air (enter comp.) Comp. air (recycled) Heating mode (T_ amb < T_ exhaust ) Comp. air (recycled) Ambient air (enters comp.) Air which exits compartment Ambient air Figure 1 Circuit of R7 HVAC cycle (example) and configuration table of the air stream directions. The glycol heat exchanger (located between the gascoolers) is applied for floor heating and is only in use during heating mode. In both heating and cooling mode the coldest air crosses gas cooler, thereby the lowest possible gascooler refrigerant side exit temperature can be achieved, which can be of temperature levels below ambient temperature. From a thermodynamic point of view system designs containing two evaporators in series and therefore operating at similar evaporation pressure are not an optimal solution, when the air side temperatures are mostly quite different. In addition, refrigerant distribution at the inlet of the second evaporator might be challenging. There are many possibilities to handle multi evaporation pressure levels: Expansion to lowest suction pressure downstream of the evaporator (not preferable), Multi stage compression Expansion via ejectors Etc. As shown in Figure 1 two stage compression can be applied as an example, while a second expansion device reduces the pressure of the liquid refrigerant downstream of the first accumulator. In this way the two evaporators can handle different evaporation temperatures. During the heating period the exhaust air is already heated, however, it has to be partly replaced by fresh air. Heat from air which leaves the passenger compartment is partly recovered in evaporator1 while the ambient air at a lower temperature is the main heat source to be cooled in evaporator. Air reversing solution (II) Solution II uses movable hatches to redirect the air flow through the HVAC system when a mode change is required. This system requires an air duct and fan system that controls the airstreams and changes them according to the requirements of the two modes. The evaporators do not have to be dimensioned to stand high pressure side since they always operates as evaporators. The system circuit is simple and there are no three way valves to control direction of refrigerant flow. This will reduce the chance of failure and leakages in the system circuit.

A) B) Recycled treated air Fresh treated air Fresh treated air Recycled treated air Figure Configuration of the air reversing HVAC system at cooling (A) and heating (B) mode During cooling mode, re-circulated air from the passenger compartment enters Evap, while ambient air is cooled by Evap 1. On the gas cooler side there are two holes in the unit roof to let the air exit the system. Ambient air on the gas cooler side first has to flow down to meet the face area of GC1 on the bottom side and than through the heat exchanger to exit the system. Air from the compartment enters the unit and exchange heat with GC then leaving the HVAC system. As the figure shows the heat exchangers are the same as in cooling mode, however, the air streams changes diagonal. The holes in the floor have also moved from the evaporator side to the gas cooler side, since during the cold season the heated air has to enter the coach. The holes in the roof are moved from above the gas coolers to above the evaporator, since it is the cooled air from either the compartment (energy recovery) or the ambient air (main heat source) which has to exit the system. Turntable solution (III) In this solution the heat pump is located on a turntable device. In Solution II all the air streams changes diagonal when to mode change from cooling to heating. When the heat pump rotates 18 the heat exchangers position changes diagonally. Solution III have a circuit where the refrigerant flows in the same direction as in Solution II, and the air streams are similar in cooling and heating mode as shown A) B) Figure 3 Configuration of the turntable HVAC system at cooling (A) and heating (B) mode

Figure Cover of turntable HVAC system (Unit 1) and turntable (Unit ) The cover of the rooftop HVAC system (unit1) includes the turntable device (unit) where the heat pump is located. Unit1 has a wall at each side and unit has a centre wall, together these walls separate the hot and cold side of the HVAC module. Unit1 has to air connections in the bottom where the treated air is distributed into the duct system of the passenger compartment. The two holes in the roof are the connection to ambient air inlet and where the exit air leaves the system. The turntable device has two holes in the floor and the roof on both sides. During cooling mode the treated air leaves the evaporator side and enters the treated air duct through the holes in unit and unit1. The holes in the roof above the evaporators on unit right hand side are closed by the roof on unit1. In the same way the holes in the floor of unit left hand side are closed by the unit1 floor. In the summer season both exhaust and fresh air exchange heat with the gas cooler side flow through the holes in the roof of unit and unit1 and than exit the system. When the system changes from cooling to heating unit is rotated 18. Than the holes in the floor fit for the gas cooler side to enter the passenger compartment and the holes in the roof fits for the air flow rate which has to be released via the evaporator, while the holes in the floor on the evaporator side are closed as well as the holes in the roof on the gas cooler side. 3. SIMULATION RESULTS The computer simulation of the system circuit as shown in Figure 1 is performed by applying and combining the following tools: RnLib, HXsim and ProII. - RnLib is a refrigerant properties library developed by NTNU-SINTEF. It calculates thermodynamic data and transport properties of refrigerants and refrigerant mixtures. - HXsim is a simulation programme developed by SINTEF. It is for dimensioning and performance calculations of heat exchangers, i.e. real heat exchangers models are applied during the calculation. - PROII/PROVISION is a simulation programmes which simulates a whole system circuits with heat exchangers, compressors, receivers, expansion valves. The following assumptions are made Cooling mode Temperature of air leaving the passenger compartment: 5 C Temperature of air leaving the evaporator: 15 C (t o = 5 C) Gascooler 1 refrigerant exit temperature = t amb + 5K Gascooler refrigerant exit temperature = t air coupè + K Heating mode Temperature of air leaving the passenger compartment: C Temperature of air entering the compartment (heated + re-circulated air): 3 C Evaporating temperature = t amb - 1K Floor heating (glycol): 5 to 3 C; ~ 3 kw Gascooler : Pinch temperature is set to 5 K. When the cycle is transcritical the pinch point occur in the outlet. When the cycle is subcritical the pinch occurs inside the exchanger. The applied and required fresh air ratios depending on the ambient temperature are shown in Figure 5. Depending on the fresh air ratio, the cooling capacity varies as shown in Figure.

Cooling capacity, compressor power [kw] 5 15 1 5 Q_evap_1 Q_evap_tot Q Evap 1 Q_evap_ Q Evap. total P_comp Q Evap P compressor Figure 5 Required amount of fresh air per coach is dependent on the ambient temperature (NS-EN 1319-1, ) 5 humidity % humidity 3% humidity % 5 1 3 5 7 8 9 1 Percentage of fresh air into the passenger compartment [%] Figure Cooling capacity and compressor power as a function of air re-circulation ratio. Figure 7 shows the simulated HVAC system efficiencies at the entire temperature range where trains are operated in Europe. Depending on relative humidity of the ambient air a heating COP between 3 and can be expected while during the cooling season efficiencies between.5 and can be obtained. A) B) humidity % humidity 3% humidity % COP_heating 3 % 3% % COP_cooling 3 % 3% % Heat capacity [kw] 1 - -3 - -1 1 Ambient temperature [ C] 18 1 x x 1 x x 1 x 1 humidity % 8 x humidity 3% humidity % - -3 - -1 1 Ambient temperature [ C] 1 5 3 35 5 5 Ambient temperature [ C] Figure 7 Simulated system efficiencies for heating (A) and cooling (B) mode of the HVAC systems. A) B) Cooling capacity [kw] 35 3 5 15 humidity % 1 humidity 3% 5 humidity % 5 3 35 5 5 Ambient temperature [ C] Figure 8 Simulated system capacities for heating (A) and cooling (B) mode of the HVAC systems. % 3% %

Figure 8 shows the simulated HVAC system heating and cooling capacities at the entire temperature range where trains are operated in Europe. The heating capacity of the applied system configuration is in the range of 18 to 1 kw while the cooling capacity ranges from 1-19 kw at low ambient temperatures to 15- kw at high ambient temperature conditions. These values are applied to calculate the energy saving potential for coaches operated in three different climate zones of Europe. Annual energy demand [MWh] Total hours 1. 1. 8 8 < - Norway (Oslo) - to -15-15 to -1-1 to -5-5 to Between and 18 (total 38h), Norway (Oslo) Germany (Frankfurt) Greece (Athens) Temperature range [ C] A) Total energy HP [MWh] B) 1 1,9 Total energy AC [MWh] 1 8,8 Germany (Frankfurt) Between and 18 (total 38h). ENERGY SAVING POTENTIALS Weather data from the METEONORM (5) library as shown in Figure 9(A) are applied to calculate the energy consumption for a typical coach, in duty during the daytime from to 18.In this case study Norway (Oslo) represents the cold European climate while Frankfurt climate was chosen as a Central European location with moderate ambient temperatures. The high ambient temperatures of Athens require a large portion of compressor energy for AC as shown in part B of Figure 9 A) B) to 5 5 to 1 1 to 15 15 to to 5 5 to 3 3 to 35 1,3 3,5 Greece (Athens) > 35 5,5 Compressor energy [MWh] 3,,5, 1,5 1,,5, Compressor energy/ Electrical heating [MWh]. < - - to -15 1 1 1 8-15 to -1 - to -15 (7%) -1 to -5-15 to -1 ( 75%) -5 to to 5-1 to -5 (7%) 5 to 1 1 to 15 Compressor energy [MWh] Heating energy [MWh] -5 to (77%) 15 to Temperature range [ C] Between and 18 (total 38h) to 5 to 5 (78%) 5 to 3 5 to 1 (8%) Temperature range [ C] Norway (Oslo) Germany (Frankfurt) Greece (Athens) Figure 9 Applied weather data/temperature bin (A) and calculated energy consumption of the compressor of the HVAC system (B). For the energy calculation it is assumed that a railway coach requires cooling when the ambient temperature is above C and heating below 15 C. Part A of Figure 1 shows the different heating and cooling demands in Northern and Southern Europe. Due to the cold climate in Scandinavia, 9% of the energy is required for heating of the passenger compartment, while only % is applied for cooling. Even in Central Europe a small share of the energy is used to cool the coach to comfort levels. However, in Southern Europe about % of the Energy is applied for cooling of the passenger compartment. 3 to 35 > 35 1 to 15 (8%) Figure 1 Annual energy demand per HVAC system (A) and Share of compressor energy versus total heating energy (B) for a coach applied in Oslo.

Figure 1 (part B) shows how much energy is required to heat a coach in Oslo at different ambient temperatures. When applying a heat pump up to 8 % of the electrical power can be saved since only the compressor energy has to be provided, while current systems require 1% electrical power to heat the coaches. GHG emissions About 5 of 175. railway-, tram- and metro units are equipped with air conditioning systems in the EU. The total refrigerant charge of these vehicles is ~1.18 metric tons. The average annual leakage rate is 5% in the railway sector. Based on this data each unit has approximately 18 kg refrigerant charge. Norwegian trains consist on average of 5 coaches which give each train a refrigerant charge of 9 kg. The calculations show that leakage from a train with the average annual leakage of 5% contributes to an annual Green House Gas emission of 3 metric tonnes CO eq. 5. DISCUSSION / CONCLUSION The energy saving potential could be further improved if the requirements for fresh air into the compartment would be based on air quality sensors inside the passenger compartment. The more people are travelling with a coach the more compartment air has to be replaced by the HVAC system. A further improvement of the system performance is expected when work recovery devices like ejectors or expanders are applied to recover partly the unutilized expansion work in R7 HVAC devices. Applying such compact R7 HVAC units for trains will contribute to a significant reduction of energy required to keep the passenger compartments at comfort level during all seasons and in most global climate zones. 7. ACKNOWLEDGEMENTS The authors would like to thank G. Vadseth (NSB) and L. Hiesche (Faiveley Transport) for their support. 8. REFERENCES 1. HAFNER, A et al. (1998) An Automotive HVAC system with CO as the Refrigerant. Proceedings of the 3rd IIR-Gustav Lorentzen Conference on Natural Working Fluids, Oslo, June -5, pp.335-35.. HAFNER, A (3) Compact Interior Heat Exchangers for CO Mobile Heat Pumping Systems, Dr.- Ing. Thesis 3:9 Faculty of Engineering Science and Technology, NTNU. 3. HAFNER, A. & NEKSÅ, P. (b) Global environmental consequensces of introducing R- 7(CO) mobile air conditioning. Proceedings of the 7th IIR Gustav Lorentzen Conference on Natural Working Fluids, Trondheim, Norway, May 8-31,.. METEONORM (5) Global Solar Radiaton Database. CD version 5.1. 5. EBINGER, I. (8) Bewertung des Energieverbrauchs von Klimaanlagen für Schienenfahrzeuge. Proccedings of the DKV annual convention, Ulm, Germany, November 8. MORGENSTERN, J. & EBINGER, I. (8) Demands to be met by future railway vehicle airconditioning systems. Der Eisenbahningenieur, December 8, page -31. 7. SCHWARZ, W. & RHIEMEIER, J.-M. (7) Final Report Maritime, Rail, and Aircraft Sector. European Commision (DGEnvironment). http://www.oekorecherche.de/english/berichte/volltext/maritime-rail-aircraft.pdf