INDOOR AIR QUALITY CCWH Complete Comfort Whole-Home Dehumidifier ENGINEERING DATA. Nominal Capacity - 65 to 135 pints per day CCWH - 090

Similar documents
Healthy Climate Whole-Home Dehumidifier. Nominal Capacity - 70 to 130 pints per day INDOOR AIR QUALITY HCWHD PRODUCT SPECIFICATIONS.

Model 1750A/ 1770A Dehumidifier Installation Instructions

CAUTION WARNING INSTALLATION INSTRUCTIONS FOR HEALTHY CLIMATE WHOLE HOME DEHUMIDIFIER MODEL HCWH-065 (Y3013) DEHUMIDIFIERS

Model 8191 & 8192 Ventilator with Dehumidification Installation and Operating Instructions

Safety and Installation Instructions Model 1700

Model 8191 & 8192 Ventilator with Dehumidification Installation and Operating Instructions

Installation, Safety & Maintenance Manual Model 1750A/1770A

Installation Guide. Dehumidification. Fresh Air Ventilation. Compact Size. Energy Efficient. RXID-AW90A Whole House Dehumidifier

Model 1870 & 1870W Dehumidifier Installation Instructions

Model DEHXXCDA1070 & DEHXXCDA1095 Dehumidifier Installation Instructions

MODEL 1830/1850/1870 DEHUMIDIFIER APPLICATION QUICK START GUIDE

Rooftop Units 60HZ. PACKAGED HEAT PUMPS 13HPP / rhp13 PRODUCT SPECIFICATIONS 13 HPP 36 A P - 1 A RHP 13 A 36 T - 1 A MODEL NUMBER IDENTIFICATION

OHR23. ELITE SERIES Horizontal/Downflow. AFUE - Up to 83.5% Input - 105,000 to 154,000 Btuh Nominal Add-on Cooling - 2 to 5 Tons O HR 23 Q 3/4-105/120

Model 1820 Dehumidifier

S1-CVD070T01A / S1-CVD095T01A Central Dehumidifier Installation Instructions. Johnson Controls Unitary Products WARNING CAUTION

Desiccant Dehumidifier

RGE 13 A T - 1 A

HEALTHY CLIMATE Heat / Energy Recovery Ventilator

DAVE LENNOX SIGNATURE COLLECTION Lo-Boy - Variable Speed Blower

MERIT Series R-410A - Upflow / Horizontal

ELITE SERIES Lo-Boy. AFUE - 83% Heating Input - 101,000 to 151,000 Btuh Nominal Add-on Cooling to 5 Ton. OIL FURNACES El0183b

HEALTHY CLIMATE PureAir Air Purification System

MERIT Series R-410A - Upflow / Horizontal

Installation Guide. Dehumidification. Fresh Air Ventilation. Compact Size. Energy Efficient. DH90 Whole House Dehumidifier

DAVE LENNOX SIGNATURE COLLECTION PureAir S Air Purification System

Model 1870F Dehumidifier Installation and Operating Manual

13 GEP A L P - 1 A

AC, HP and Air Handler Units Up to 20 Tons. Commercial Split Systems. Reliable, cost-effective and servicefriendly split systems inside and out

Model 8140 & 8141 Fresh Air Ventilator Installation and Operations Manual

Advance Release September 2009

T-CLASS Commercial Split Systems Up to 20-Ton TSA/TPA Models

V8MS Mode Selection Box for VRA Heat Recovery - 60HZ

MERIT SERIES Up Flow / Horizontal

2 shp 13 lc 1 36 t - 1 a

B24/C22/24 COILS BLOWER COIL UNITS ENGINEERING DATA. Bulletin # June 1994 Supersedes August B24 Blower Unit (With Optional Electric Heat)

T-SERIES SPLIT SYSTEM UNITS R-410A - 60 HZ. EER up to to 20 Tons Cooling Capacity - 71,000 to 236,000 Btuh AIR CONDITIONERS TS

Performance and rugged durability. Commercial Split Systems Up to 20-Ton TSA/TPA Models

CB18/CBS18 Bulletin # September 1994 Supersedes August 1986

READ AND SAVE THESE IMPORTANT SAFETY INSTRUCTIONS

50Hz AC, HP and Air Handler Units Up to 70 kw. Commercial Split Systems. Reliable, cost-effective and servicefriendly split systems inside and out

MODELS TR & TRC TOTAL RECOVERY FOR ALL CLIMATES RESIDENTIAL OR COMMERCIAL APPLICATIONS

T-CLASS GAS-FIRED UNIT HEATERS Separated Combustion - Direct Vent - Horizontal - 60 HZ. Thermal Efficiency - up to 82% Input - 40,000 to 300,000 Btuh

Model 1850F Dehumidifier Installation and Operating Manual

MERIT SERIES Downflow

INSTALLER S & OWNER S MANUAL

Installation Instructions

4HP15L PRODUCT SPECIFICATIONS HIGH EFFICIENCY SPLIT HEAT PUMP SYSTEM UP TO 15 SEER & 9.0 HSPF COILS COMPONENTS COMPRESSOR WARRANTY CABINET DESIGN

ELITE Series R-410A. SEER up to to 5 Tons Cooling Capacity - 17,800 to 60,000 Btuh AIR CONDITIONERS EL16XC1 PRODUCT SPECIFICATIONS

Fresh Air Ventilation

Model 8120 and 8126 Safety & Installation Instructions

Installation, Operating and Maintenance Manual

High Heat COP. High/Low Stage

3 to 5 Tons. AIR CONDITIONERS 2scu13. Dry Charge Split System - 60 HZ PRODUCT SPECIFICATIONS. 2 scu 13 lc 1 36 t - 1 a MODEL NUMBER IDENTIFICATION

Quest 105, Dry155, and 205 Dual

MODELS TR & TRC TOTAL RECOVERY FOR ALL CLIMATES RESIDENTIAL OR COMMERCIAL APPLICATIONS

ELITE SERIES Downflow - High Efficiency Blower Motor

Outside Air Requirements... SOLVED!

Aprilaire Dehumidifier Troubleshooting Manual Models 1830, 1850, 1870

Aprilaire Dehumidifier Troubleshooting Manual Models 1830 & 1850

Model 8142 and 8142NC Fresh Air Ventilator Installation and Operating Instructions

62DA,DB,DC,DD,DE,DF07-38

15CHPX. DAVE LENNOX SIGNATURE COLLECTION Residential - R-410A - Variable Speed Blower

LRP14AC. SEER to 5 Tons Cooling Capacity - 22,600 to 57,000 Btuh Optional Electric Heat - 5 to 20 kw. Residential - R-410A

MERIT Series R-410A. SEER up to to 5 Tons Cooling Capacity - 17,500 to 59,000 Btuh AIR CONDITIONERS 13ACXN PRODUCT SPECIFICATIONS

COMPACT UNIT HEATERS Low Profile - Horizontal - 60 HZ. Steady-State Efficiency - up to 81% Input - 30,000 to 75,000 Btuh

Ultra-Aire 150H Whole House Ventilating Dehumidifier

MIN. CCT. QTY RLA LRA HP FLA AMPACITY /1/ /3/

INSTALLATION INSTRUCTION & OWNER S GUIDE

Installation, Operation and Maintenance Instructions

T P A 120 S 4 S N 1 Y

Quest Dry 105, 155, and 205 Dual

Installation Instructions for Heat Recovery Ventilators with 2 Speed RNC Electronics. RNC Series. Residential Heat Recovery Ventilators (HRV)

Dehumidifiers. Model 1830/1850/1850F/1850W. OTHER PARTS (Not Shown)

MODEL TRC TOTAL RECOVERY FOR ALL CLIMATES - COMMERCIAL APPLICATIONS

Quest Dry 150 Dual. quest Asset Protection and IAQ Solutions. Read and Save These Instructions. Installation, Operation and Maintenance Instructions

Hood Depot Internatioonal, Inc., Phone S. Powerline Road, Deerfield Beach, FL

Rooftop Ventilator. Models RV and RVE. with Packaged Cooling & Heating

Direct Fired Heater Model AD Specification

UNIVERSITY OF MISSOURI Heating Ventilating and Air-Conditioning (HVAC) 2016 Q1

THE WALL-MOUNT ONE TON AIR CONDITIONER GREEN REFRIGERANT R-410A. 10,800 Btuh 9.00 EER Right Side Control Panel. Engineered Features

Quest Dry. Quest 110 Dual. Read and Save These Instructions. Installation, Operation and Maintenance Instructions

VentZone Systems VentZone Zoned IAQ with Heat Recovery Kits

IAQ VENTILATION SOLUTIONS

CROWN. Boiler Co. Santa-Fe Series. Hydronic Air Handlers INSTALLATION, OPERATION & MAINTENANCE INSTRUCTIONS

DRY CHARGE UNITS. 1.5 to 5 Tons AIR CONDITIONERS LCS13DC PRODUCT SPECIFICATIONS L C S 13 DC MODEL NUMBER IDENTIFICATION

Internal ridged board 1" x 1.5 foil face installation shall be installed on roof, walls and base of casing.

KIC Air Curtains. Technical Guide

Model 8140 and 8140NC Fresh Air Ventilator Installation and Operating Instructions

Nominal Capacity 024 = 7 kw (2 tons) 036 = 10.5 kw (3 tons) 048 = 14 kw (4 tons) 060 = 17.5 kw (5 tons)

HVAC Equipment Access Equipment Location

BARD MANUFACTURING COMPANY, INC. WG3S-WG5S 2-Stage Cooling with Gas Heat Engineering Specification Guide

IAQ VENTILATION SOLUTIONS

MX Series Indoor Modular Blowers Electric Heat, Hot Water Heat, or No Heat

INSTALLER S & OWNER S MANUAL

icomfort Residential Communicating Control System icomfort Touch Communicating Thermostat

DIGI3U. Zoning Systems. Installation Guide. That s all we do. Three-Zone, Universal Controller for Gas/Electric or Heat Pump Applications

Model 1730A Compact Dehumidifier Installation Instructions

ISERIES VERTICAL AHU ENGINEERING SPECIFICATIONS

S1-CD065T01 Central Dehumidifier Installation Instructions. Johnson Controls Unitary Products WARNING CAUTION SPECIFICATIONS LOCATION CONSIDERATIONS

INSTALLER S & OWNER S MANUAL

Transcription:

ENGINEERING DATA INDOOR AIR QUALITY CCWH Complete Comfort Whole-Home Dehumidifier Bulletin No. CCWH (08/2011) CCWH-065 CCWH-090 CCWH-135 ENERGY STAR Rating for CCWH-065 Model Only Nominal Capacity - 65 to 135 pints per day Model Number Identification CCWH - 090 Unit Type CCWH = Complete Comfort Whole Home Dehumidifier Nominal Capacity 065 = 65 pints per day 090 = 90 pints per day 135 = 135 pints per day FEATURES Contents Dimensions...10 Features...1 Installation Clearances...11 Model Number Identification...1 Optional Accessories...4 Performance...5 Sizing Guidelines...8 Specifications...4 Typical Applications...9 WARRANTY All covered components Limited five year warranty in residential applications, one year in non-residential applications. Refer to Equipment Limited Warranty certificate included with equipment for details. APPROVALS All units are E.T.L. Listed. Energy Star certified unit (CCWH-065 model only) is designed to use less energy, help save money on utility bills, and help protect the environment. APPLICATIONS The Complete Comfort Whole Home Dehumidifier is designed to control humidity throughout the home or in specific locations such as an attic or basement. Also used for air cycling and ventilation control. CCWH-090 and CCWH-135 models are equipped with a humidity sensor that automatically and continually measures the relative humidity. Based on that measurement, the unit will operate to control the humidity based on the set point. CCWH-090 and CCWH-135 models feature a built-in, automatic air cycling feature can be utilized to activate the furnace/air handler blower to cycle air throughout the whole home for proper balance and comfort. CCWH-090 and CCWH-135 models feature a patented, built-in ventilation feature allows fresh air to be brought into the home from the outside. The dehumidifier will condition the incoming air, if needed.

FEATURES Filter Includes washable, MERV 8 (Minimum Efficiency Reporting Value) filter. Blower CCWH-065 Model Blower assembly is a UL approved impeller type with backward curved centrifugal fan equipped with maintenance free ball bearings. CCWH-090-135 Models Blower assembly includes shaded-pole, heavy-duty, direct drive blower and blower wheel. Operates during both ventilation and dehumidification modes. Compressor R-410A, rotary-type compressor. Cabinet Constructed of 22 gauge, pre-painted steel. Interior is lined with 1 in., foil-faced, expanded polystyrene to eliminate noise, condensation and air loss. Duct start collars are included. CCWH-065 only - Supply collar can be relocated from the end of the cabinet to the top if space is restricted The supply outlet is equipped with a built-in backflow damper. Adjustable feet (-065 model up to 4 in., -090-135 models - up to 3 in.) to level unit. If the dehumidifier is installed in an attic or location requiring leak protection, the unit should be placed in a secondary condensate drain pan with a normally closed condensate overflow safety switch (float switch). Controls CCWH-065 Model Dehumidistat is furnished and factory installed on the unit cabinet inlet panel. It can be easily removed for relocation to another area within the living space. The dehumidistat continually measures the humidity in the air to control the dryness level set on the dial. Terminal strip for connections of HVAC equipment, furnace or air handler and float switch. When connected to HVAC equipment the dehumidifier automatically controls indoor blower operation during dehumidification operation. Two on-board LED s provides instant status of operation and maintenance required. Power is applied to system - Green Service Required - Red Three internal, amber LED s provide status of dehumidifier impeller (DEH), compressor (COMPR) and indoor unit blower (HVAC) (if applicable). Viewable when the dehumidifier cover is removed. CCWH-090-135 Models Factory installed control handles operation of unit. Terminal strip for connections of furnace/air handler, float switch, ventilation dampers, outdoor air sensor, and optional Whole-Home Dehumidistat. DIP switches are used to configure system set (whole house, zoned or combination system) and ventilation times (30, 60, 90 or 120 minutes). DIP switches are used to configure ventilation cycle periods (1/2, 1, 2, or 3 hours) and a knob for configuring cycle times (from 0 to 60 minutes). Knob on the front of the unit sets the desired humidity level. On-board humidity sensing allows for better whole home monitoring and control of humidity. Optional remote Whole-Home Dehumidistat can be used to provide easy humidity control accessibility. On-board LED provides instant status of operation and maintenance required. Normal Operation Green Air Sampling or Defrosting Flashing Green Service Required Flashing Red When equipped with overflow safety switch (field provided and installed), the dehumidifier will continue to ventilate but the compressor is disabled when the switch is open. CCWH Complete Comfort Whole-Home Dehumidifier / Page 2

FEATURES REQUIRED COMPONENTS (-065 MODEL ONLY) Drain Pan Required if unit is installed in an attic or location requiring leak protection. (-090, -135 MODELS ONLY) Backflow Damper Constructed of rolled galvanized steel with stiffening ribs to maintain rigidity. A single steel offset blade is attached to a one piece aluminium shaft connected with nylon bearings for smooth operation. Spring return, normally closed, power open. Requires 24V transformer ordered separately. Transformer 120V primary, 24V secondary, 40VA transformer for powering backflow damper. OPTIONAL ACCESSORIES OPTIONS (-090, -135 MODELS ONLY) Whole-Home Dehumidistat Whole-Home Dehumidistat is used to control the dehumidifier if the unit is installed in a difficult to access location such as an attic or crawl space. Provides an accessible means of turning the dehumidifier on and off and allows for adjustment of the humidity level set point. Control contains its own sensors that override the dehumidifier s main control board sensors. Basement Kit Includes components typically needed for basement dehumidification application. Includes two 8-in. normally open dampers, two 8-in. normally closed dampers and one 24V, 40VA transformer. Ventilation and Zone Dampers Constructed of rolled galvanized steel with stiffening ribs to maintain rigidity. A single steel offset blade is attached to a one piece aluminium shaft connected with nylon bearings for smooth operation. Spring return with a normally closed or normally open configurations are available.requires 24V transformer ordered separately. Transformer 120V primary, 24V secondary, 40VA transformer for powering dampers. Outdoor Air Temperature Sensor Prevents the CCWH from using outside air for ventilation if the outdoor temperature is above 100 F or below 0 F. Ventilation (-090-135 MODELS ONLY) The built-in ventilation feature is designed to be meet ASHRAE 62.2 Standard for Ventilation. Utilizes the dehumidifier and furnace/air handler blower to make-up any remaining ventilation required based on chosen set point. In hot, humid climates, supplemental dehumidification of fresh air is recommended. Automatically monitors and controls the humidity of the incoming air. The dehumidifier can also operate an optional ventilation damper to bring air in from outside. To keep it from using outdoor air above 100 F or below 0 F, an optional Outdoor Temperature Sensor must be field installed. Air Cycling (-090-135 MODELS ONLY) An integrated air cycling feature can activate the furnace/air handler blower to cycle air through the house to balance the indoor air conditions. Monitors furnace/air handler blower run-time to efficiently ventilate the whole home, Air cycling will cycle furnace/air handler blower to the values set on the control. CCWH Complete Comfort Whole-Home Dehumidifier / Page 3

SPECIFICATIONS Model No. CCWH-065 CCWH-090 CCWH-135 1 Capacity 65 pints per day 90 pints per day 135 pints per day Refrigerant R-410A R-410A R-410A Sound Level (dba) Ducted 52 48 54 Unducted 57 53 67 Connections - in. Drain diameter 3/4 3/4 3/4 Duct diameter 8 8 8 Humidity Range Inlet 30-99% 30-100% RH 30-100% RH Ambient Operating 0-100% 0-100% 0-100% Blower Data Air Flow 150 cfm @ 0.5 in. w.c. 275 cfm @ 0.6 in. w.g. 500 cfm @ 0.8 in. w.g. Filter Type Washable, MERV 8 Washable, MERV 8 Washable, MERV 8 Size - in. 11-5/8 x 11-5/8 x 1 17 x 18 x 1 17 x 18 x 1 Electrical General 120V - 60 hz - 1 ph 120V - 60 hz - 1 ph 120V - 60 hz - 1 ph Power Supply 15 Amps 15 Amps 20 Amps Rated Amperage 8 Amps 8 Amps 14 Amps Connection 8 ft.,3-prong power cord Blower Motor Full Load Amps 1.6 1.1 Weight - lbs. 65 93 100 REQUIRED COMPONENTS Backflow Damper 8 in. Normally Closed (NO) - - - Y2264 Y2264 Transformer for Backflow Damper OPTIONAL ACCESSORIES Basement Kit - includes 2-8 in. NO dampers, 2-8 in. NC dampers, one 24V, 40VA transformer. 24V, 40VA Transformer - - - 22N03 22N03 - - - X4471 X4471 Drain Pan (required for attic installations) Y3196 - - - - - - Dampers Ventilation Damper - 6 in. Normally Closed (NO) - - - X4152 X4152 Zone Damper - 8 in. Normally Open (NO) - - - X4209 X4209 Damper Transformer, 24V, 40VA - - - 22N03 22N03 Whole-Home Dehumidistat - - - CC139 CC139 Outdoor Air Temperature Sensor - - - CC138 CC138 1 Capacity based on 60% relative humidity at 80 F (ANSI/AHAM DH-1-2003 conditions). CCWH Complete Comfort Whole-Home Dehumidifier / Page 4

PERFORMANCE 1.20 CCWH-065 Dehumidifier Pressure/Airflow Curve Coil Dry, Air Filter Clean 1.00 External Static Pressure ("w.c.) 0.80 0.60 0.40 0.20 Minimum Recommended Airflow = 140 CFM Design System for 0.4" w.c. max. External Pressure Drop Filter Pressure Increase = 0.2" w.c. 0.00 0 50 100 Airflow (CFM) 150 200 250 1.20 CCWH-090 Dehumidifier Pressure/Airflow Curve Coil Dry, Air Filter Clean External Pressure Drop = HVAC System + Damper (0.05" w.c./unit) + 8" flex duct @ 275 cfm (Pressure drop of 8" flex @ 275 cfm = 0.23" w.c./100 feet) 1.00 re (" w.c.) External Static Pressur 0.80 0.60 0.40 Minimum Recommended Airflow = 200 CFM Design System for 0.6" w.c. max. External Pressure Drop Filter Pressure Increase = 0.2" w.c. 0.20 0.00 0 50 100 150 200 250 300 350 400 450 Airflow (CFM) CCWH Complete Comfort Whole-Home Dehumidifier / Page 5

PERFORMANCE CCWH-135 Dehumidifier Pressure/Airflow Curve Coil Dry, Air Filter Clean 1.90 1.70 External Pressure Drop = HVAC System + Damper (0.05" w.c./unit) + 8" flex duct @ 500 cfm (Pressure drop of 8" flex @ 500 cfm = 0.75" w.c./100 feet) External Static Pressur re (" w.c.) 1.50 1.30 1.10 0.90 0.70 Minimum Recommended Airflow = 430 CFM Design System for 1.3" max. External Pressure Drop Filter Pressure Increase = 0.2" w.c. 0.50 0.30 300 350 400 Airflow (CFM) 450 500 550 CCWH-065 - CAPACITY - PINTS PER DAY 50 - - - - - - 30 41 52 54 56 55 - - - 15 37 48 59 62 65 60 4 24 43 54 65 69 74 65 9 30 52 63 74 65 56 70 13 37 61 72 82 61 39 75 15 39 63 69 76 56 37 80 17 41 65 67 69 52 35 CCWH-065 - LEAVING AIR TEMPERATURE 50 - - - - - - 92 101 110 115 120 55 - - - 80 93 103 113 119 124 60 68 81 93 105 116 122 128 65 74 86 98 108 118 119 121 70 80 91 102 111 120 117 113 75 81 92 103 111 118 115 112 80 81 93 104 110 116 113 110 CCWH-065 - ENERGY USE - PINTS PER KW/HR 50 - - - - - - 2.11 2.53 2.96 3.06 3.17 55 - - - 1.06 2.43 2.75 3.06 3.22 3.38 60 0.21 1.48 2.75 2.96 3.17 3.38 3.59 65 0.95 2.11 3.27 3.48 3.70 3.59 3.48 70 1.69 2.75 3.80 4.01 4.22 3.80 3.38 75 2.11 3.01 3.91 4.07 4.22 3.75 3.27 80 2.53 3.27 4.01 4.12 4.22 3.70 3.17 CCWH-065 - LEAVING AIR % RELATIVE HUMIDITY 50 - - - - - - 19 16 13 13 13 55 - - - 25 19 16 13 13 14 60 30 24 18 16 13 14 14 65 29 23 17 15 13 18 24 70 28 22 15 14 13 23 33 75 25 21 18 18 18 26 34 80 22 21 20 21 22 28 34 CCWH-065 CAPACITY AND ENERGY USAGE VS. STATIC PRESSURE Static Pressure - in. w.g. 0.0 0.3 0.5 0.8 Capacity - Pints Per Day 69 65 61 51 Energy Usage - Pints per kw/hr 4.50 4.03 3.67 2.89 NOTE - Tested at 80 F/60% relative humidity. CCWH Complete Comfort Whole-Home Dehumidifier / Page 6

PERFORMANCE CCWH-090 - CAPACITY - PINTS PER DAY 50 - - - 16 48 57 66 76 86 55 6 31 60 69 78 88 98 60 11 47 73 81 90 100 110 65 26 58 84 93 102 111 120 70 41 70 95 104 114 122 130 75 55 85 104 114 124 135 146 80 69 101 112 123 134 147 161 CCWH-090 - LEAVING AIR TEMPERATURE 50 - - - 74 84 90 97 103 109 55 71 76 86 92 98 104 109 60 74 79 88 93 100 106 111 65 75 80 90 96 104 110 114 70 76 81 92 97 107 112 116 75 78 84 93 100 108 114 120 80 81 88 93 102 109 115 124 CCWH-090 - ENERGY USE - PINTS PER KW/HR 50 - - - 1.03 2.91 3.26 3.61 3.95 4.29 55 0.42 1.97 3.59 3.89 4.19 4.49 4.79 60 1.06 2.91 4.27 4.52 4.77 5.04 5.30 65 2.11 3.59 4.79 5.01 5.23 5.43 5.64 70 3.17 4.26 5.32 5.50 5.68 5.83 5.98 75 3.80 5.02 5.79 5.95 6.11 6.26 6.41 80 4.65 5.79 6.25 6.40 6.55 6.70 6.84 CCWH-090 - LEAVING AIR % RELATIVE HUMIDITY 50 - - - 34 26 24 23 22 22 55 37 33 26 24 23 22 22 60 35 30 26 24 23 23 22 65 34 30 26 24 23 22 23 70 33 30 26 24 22 22 23 75 31 28 26 24 23 22 23 80 28 26 26 24 23 23 22 CCWH-135 - CAPACITY - PINTS PER DAY 50 - - - 15 50 74 99 114 130 55 19 32 76 97 117 129 142 60 17 60 103 119 135 144 154 65 39 81 123 138 153 161 169 70 62 102 142 157 171 177 184 75 82 119 155 170 186 193 201 80 103 136 168 184 200 209 217 CCWH-135 - LEAVING AIR TEMPERATURE 50 - - - 71 84 92 100 105 111 55 68 74 87 94 102 108 114 60 73 81 90 97 105 111 117 65 76 84 92 99 106 113 119 70 79 87 95 101 108 115 123 75 82 89 95 103 110 117 124 80 85 91 96 104 112 119 126 CCWH-135 - ENERGY USE - PINTS PER KW/HR 50 - - - 0.84 1.65 2.11 2.32 2.53 2.96 55 0.91 1.55 2.32 2.75 3.17 3.38 3.59 60 1.06 1.69 2.96 3.38 3.85 3.80 4.01 65 1.48 2.53 3.38 3.80 4.22 4.22 4.22 70 2.11 3.17 4.01 4.44 4.65 4.44 4.35 75 2.96 3.80 4.65 4.86 4.86 4.86 4.86 80 3.59 4.22 5.07 5.28 5.49 5.49 5.70 CCWH-135 - LEAVING AIR % RELATIVE HUMIDITY 50 - - - 40 28 24 21 21 20 55 43 40 28 23 21 21 21 60 42 36 28 23 21 21 21 65 41 36 28 24 21 21 22 70 39 34 28 24 21 21 22 75 38 31 28 23 21 21 21 80 38 32 28 25 21 20 19 CCWH-135 CAPACITY AND ENERGY USAGE VS. STATIC PRESSURE Static Pressure - in. w.g. 0 0.5 0.7 0.9 1.3 1.5 Capacity - Pints Per Day 137 136 135 135 133 131 Energy Usage - Pints per kw/hr 3.92 3.86 3.84 3.85 3.78 3.61 NOTE - Tested at 80 F/60% relative humidity. CCWH Complete Comfort Whole-Home Dehumidifier / Page 7

SIZING GUIDELINES 1. Find the home location (and corresponding region) in the map below 2. Estimate the air change rate of the home: a. 1.00 air change per hour is an older home, that is not particularly tight. b. 0.50 air change per hour is a reasonably tight home. c. 0.35 air change per hour is a very tight home, typical of new home construction. 3. Determine how many dehumidifiers are required by comparing the actual home size and corresponding air change rate, to the Maximum Recommended Home Size in the table. 4. This is a general guideline. Consider any special circumstances that may require more water removal capacity and, if necessary, adjust your dehumidifier choice(s) accordingly. A B C CCWH-065 CCWH-090 CCWH-135 Air Change Per Hour (ACH) 1.00 0.50 0.35 1.00 0.50 0.35 1.00 0.50 0.35 Maximum Recommended Home Size (sq. ft.) Region A 2600 3600 3600 3600 5000 5000 5400 7400 7400 Region B 2000 3200 3600 2800 4500 5000 4100 6700 7400 Region C 1200 1800 2400 1700 2600 3400 2500 3800 5000 NOTES: - Based on a single-story, slab construction home with four occupants. - Dehumidistats set to less dry; thermostat set to auto-fan. - Air conditioner with thermostat cooling set to at least 79 F. - TMY 2 (Typical Meteorological Year) weather data; 1.00 lb./hr. internal moisture gain due to occupants. CCWH Complete Comfort Whole-Home Dehumidifier / Page 8

TYPICAL APPLICATIONS CENTRAL APPLICATION (All Models) SUPPLY AIR FLOW AIR HANDLER OR FURNACE RETURN AIR FLOW **OPTIONAL VENTILATION DEHUMIDIFIED AIR HCWH DEHUMIDIFIER OUTDOOR AIR INTAKE *BACKFLOW Note - HCWC bypass ducts must be a minimum of 6 in. (127 mm) from the supply or return air openings of the air handler/furnace *Backflow damper is furnished on HCWH-065 Model, optional for HCWH-090-135 Models. **For use with HCWH-090-135 Models only. ZONED APPLICATION (All Models) OUTDOOR AIR INTAKE OPTIONAL VENTILATION SUPPLY AIR FLOW AIR HANDLER OR FURNACE RETURN AIR FLOW DEHUMIDIFIED AIR HCWH DEHUMIDIFIER AIR FLOW ENTERING AIR COMBINATION CENTRAL AND ZONED APPLICATION (CCWH-090-135 Models Only) SUPPLY AIR FLOW AIR HANDLER OR FURNACE RETURN AIR FLOW NORMALLY CLOSED NORMALLY CLOSED NORMALLY OPEN DEHUMIDIFIED AIR HCWH DEHUMIDIFIER ENTERING AIR NORMALLY OPEN OPTIONAL VENTILATION OUTDOOR AIR INTAKE CCWH Complete Comfort Whole-Home Dehumidifier / Page 9

DIMENSIONS - INCHES (MM) CCWH-065 13-1/8 (333) Wiring Access 2-1/2 (64) 22-1/8 (562) 2-1/2 (64) 13-1/8 (333) OFF/ON Switch Humidity Control 8 (203) Dia. 14-1/2 (368) Air Flow 8 (203) Dia. Drain Adjustable Legs 4 (102) Max. Power Cord Filter Access (Front and Back) 1-3/8 (35) 1 (25) OUTLET AIR END FRONT VIEW INLET AIR END CCWH-090 AND CCWH-135 20-3/4 (527) 2-1/2 (64) 24 (610) 2-1/2 (64) Humidity Control 20-3/4 (527) 8 in. Dia. 8 in. Dia. 19-5/8 (498) OFF/ON Switch OFF ON Drain Air Flow Wiring Access 1-1/4 (32) 10-3/8 (264) Power Cord Filter Access (Front and Back) Adjustable Legs 3 (76) Max. OUTLET AIR END FRONT VIEW INLET AIR END CCWH Complete Comfort Whole-Home Dehumidifier / Page 10

INSTALLATION CLEARANCES - INCHES (MM) CCWH-065 Support struts for suspending (bottom of unit) 2-1/8 (54) clearance from leveling feet 12 in. (305 mm) control access clearance, both ends SERVICE CLEARANCE 12 in. (305 mm) filter/front panel service clearance (either side) 4-1/2 in. (114 mm) filter access panel clearance (either side) If suspending the unit, use two struts to support the base on the outside edges of the feet locations. NOTE - Minimum clearance of 3 in. (76 mm) from unit to strut suspension rod (access panel side only) is required for filter panel access removal. CCWH-090 AND CCWH-135 Support struts for suspending (bottom of unit) TOP VIEW OF UNIT 12 in. (305 mm) control access clearance, both ends See NOTE SERVICE CLEARANCE 20 in. (508 mm) filter/front panel service clearance (either side) 6 in. (152 mm) filter access panel clearance (either side) If suspending the unit, use two struts to support the base on the outside edges of the feet locations. NOTE - Minimum clearance of 3 in. (76 mm) from unit to strut suspension rod (access panel side only) is required for filter panel access removal. CCWH Complete Comfort Whole-Home Dehumidifier / Page 11

REVISIONS Approvals Document Added ENERGY STAR rating for CCWH-065 model. Added performance data for all models. Visit us at www.alliedair.com For the latest technical information, www.alliedair.com Contact us at 800-448-5872 NOTE: Due to Allied Air Enterprises ongoing commitment to quality, specifications, ratings and dimensions subject to change without notice and without incurring liability. Improper installation, adjustment, alteration, service or maintenance can cause property damage or personal injury. Installation and serivce must be performed by a qualified installer and servicing agency. A Lennox International Inc. Company Form Number: CCWH (08/2011) 2011 Allied Air Enterprises, a Lennox International Inc. Company