Product Bulletin. VeriSafe Absence of Voltage Tester. The Safe Way to Verify the Absence of Voltage.

Similar documents
Easy to use, initiate test with the push of a button No additional tools required Provides visual alert to abnormal power conditions

Product Bulletin. VeriSafe Absence of Voltage Tester. The Safe Way to Verify the Absence of Voltage.

Designed for testing three-phase circuits up to 600V Install on line or load side of electrical disconnect Detects absence of AC and DC voltage

Product Bulletin. VeriSafe Absence of Voltage Tester. The Safe Way to Verify the Absence of Voltage.

VeriSafe Absence of Voltage Tester The safe way to verify the absence of voltage

The safe way to verify the absence of voltage.

StructuredGround Direct Burial Compression Grounding System

NECA S System Approach to Electrical Safety for NFPA 70E

NECA S System Approach to Electrical Safety for NFPA 70E

For technical questions, contact: Grace Engineered Products Inc./ 5001 Tremont Ave, Davenport, IA /

INSTALLATION AND OPERATING INSTRUCTIONS R-3F2-LXX

LINETRAXX RCMA420. Residual current monitor for monitoring AC, DC and pulsed DC currents in TN and TT systems

isopv and AGH-PV Ground Fault Detector for Ungrounded Solar Arrays up to 1100 V And Isolation Tester Prior to Array Startup (Grounded and Ungrounded)

THERMAL BUILDING SOLUTIONS EN-TraceTekTTSIM1A-IM-H /16

TTSIM-2 TRACETEK SENSOR INTERFACE MODULE WITH LCD AND RELAY INSTALLATION/OPERATION INSTRUCTIONS

Sensor Interface Module Installation/Operation Instructions

INSTALLATION GUIDE. AXIS A1001 Network Door Controller

6/23/ National Electrical Contractors Association and Intec, Inc.

GM420. Digital Ground Continuity Relay For AC Systems. Technical Bulletin NAE /

C-Bus Four Channel General Input Unit Installation Instructions

NECA. Standard for Electrical Safety in the Workplace

Control Panel 2.0 Installation Guide

CurrentGuard TM. Installation, Operation and Maintenance Manual. CurrentGuardTM. Flush Mount. Surge Protective Devices A00

Industrial Automation Enclosure

C-Bus Four Channel Analogue Output Unit Installation Instructions

TTSIM-1A. TraceTek Sensor Interface Module with Relay. Installation/Operation Instructions. Installation Items (not supplied) Tools Required.

CMD420 / CMD421 Series

LINETRAXX VME420. Multi-functional relay for overvoltage, undervoltage and frequency monitoring in AC/DC systems with external supply voltage

NATIONAL ELECTRICAL CODE (NEC) & NFPA 70E ARC FLASH ELECTRICAL SAFETY

Safety requirements for voltage testing instruments

Wireless Occupancy Sensor:

Supplement. Title: 365 Users Supplement Issue: 8 Part Number: Issue Date: 7/16 Print Date: August 2010 Page Count: 6 Revision/Date:

Multi-Gas-Controller MGC2

GasGard 100 Control System

L1L2L3. 99 Washington Street Melrose, MA Phone Toll Free Visit us at

LINETRAXX VMD420. Multi-functional voltage relay for 3(N)AC systems, frequency/overvoltage/undervoltage, phase, phase failure, asymmetry

ISOMETER IR425. Insulation monitoring device for unearthed AC/DC control circuits (IT systems)

Universal Dimmer N 528D01, 2 x 300VA, AC 230 V 5WG DB01

Solid Core and Split Core 4-20 ma Output Current Sensors CTS-20; CTP-20

IntelliLED TM. Daylight Harvesting Sensor (DLH): User Guide

Operation Manual Part-No

Pasto Sous vide water bath

Operation and use. Functions and characteristics

Electrical Safety Requirements

DTA. Motor thermistor relay. Benefits. Description

COMPLIANCE without compromise SAFETY without sacrifice YOUR RESULTS MATTER

Panoramic Power System. PAN-14 User Guide

isopv425 and AGH420 Ground Fault Detector for Ungrounded Solar Arrays < 100 kw And Isolation Tester Prior to Array Startup (Grounded and Ungrounded)

FF-SR Series. FF-SR25933 Two-hand Safety Control Module FF-SR25933

SECTION AUTOMATIC TRANSFER SWITCHES

NFPA 70E Electrical Safety & Arc Flash Training

Square D Clipsal Outdoor Light-Level Sensor

SBS-H2. Hydrogen Gas Detector Kit. For battery charging rooms and other areas where hydrogen gas may be present

XYR 6000 SmartCET Wireless Corrosion Monitoring Transmitter

2014 National Electrical Code & NFPA 70E/Arc Flash

Pilz Safety Lockout System (PSLS)

WH231/WR231. General Features. Operational Information. Discharge 11 gpm at 40 psig (0.69 lps at 28 m) 7.8 gpm at 80 psig (0.

SITESTAR CABINET DESCRIPTION

Cat. N. Cat. N (s) 1. DESCRIPTION - USE 3. OVERALL DIMENSIONS. Technology : 4. PREPARATION - CONNECTION 2. PRODUCT RANGE

LC3000 Level Controller Installation and Maintenance Instructions

panasonic.net/id/pidsx/global Lights up when conditions are normal (and at incipient liquid leak detection) Use as a warning Sensor

User Guide. Luxxor. 35 LED Light Source Fax: Tremont Street, Rochester, New York gradientlens.

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

Chromalox. Installation, Operation. Screw Plug Heating Solution Control Panel Assembly for Screw Plug Heaters RENEWAL PARTS IDENTIFICATION

STRIKE GUARD DELIVERS:

NFPA 70E Edition Update

Inductive Conductivity Measurement. Simultaneous display of conductivity/ resistance/salinity and temperature; large measurement symbol.

WD-CS. Water leak detection cable. Technical Overview. Features. Page 1. Data Sheet Ref: Issue: 5.1.

HP Power Distribution Unit with Power Monitoring (Models S124 and S132) User Guide

Process Alarm Module RTA 421

Bulletin 140G Molded Case Circuit Breakers Product Selection 225 A, I-Frame

Motion tracking. sensor led light. Installation & operating manual NIGHTWATCHER. Model no: nw1200x

SOLARLOK Interconnection System Installation Manual

Installation Guide for AL600ULM. Multi-Output Access Control Power Supply Charger. Rev

Manual Supplement. This supplement contains information necessary to ensure the accuracy of the above manual.

PCD/PEM Power Conversion Department - Equipment Lockout Procedure

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

ACCS-30. Multipoint commercial heat-tracing control system

VeriSafe AVT. Absence of Voltage Tester Instruction Manual. Models: VS-AVT-C02-L10, VS-AVT-C02-L03, VS-AVT-C08-L10, VS-AVT-C02-L03A, VS-AVT-C08-L10A

ITC 2000 HEATING CONTROL CABINET. Installation & Operation Manual

DEB71. Earth Leakage Monitoring Relay. Benefits. Description

Dipl.-Ing. W. Bender GmbH & Co. KG Londorfer Str Grünberg Tel.: Fax:

Solid Core and Split Core Fixed Current Status Switches CSS-O,C; CSP-O,C -F (FIXED) SERIES

Installation Instructions

Functional Safety of Machinery Presented by Greg Richards Manufacturing in America 02/22-23/2017

GEM-C Wireless User & Installation Manual. Revision October Apollo Solar Electric Limited. Documentation

Enraf Servo Gauge 854 XTG

SAFETY MANAGER SC Ensure safety, simplify operations and reduce lifecycle costs

SAFETY MANUAL. X2200 UV, X9800 IR, X5200 UVIR SIL 2 Certified Flame Detectors

VeriSafe AVT. Absence of Voltage Tester Instruction Manual Models: VS-AVT-C02-L10, VS-AVT-C02-L03, VS-AVT-C08-L10

DTA04. Motor thermistor relay. Benefits. Description

safe and your operations compliant

Safety Function: Single-beam Area Access Control (AAC)

Bulletin 1608N MiniDySC Dynamic Sag Corrector

PROCESS AUTOMATION PROTECTING YOUR PROCESS THE DEFINITION FOR INTRINSIC SAFETY K-SYSTEM K-SYSTEM THE MOST TRUSTED NAME.

Models 4623, 4628 & 5999/980 USP<645> Conductivity Analyzers

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

A. Product Data: For each electrical identification product indicated. B. Comply with 29 CFR and 29 CFR

ANSI-ASQ National Accreditation Board/ACLASS

C-Bus Pascal Automation Controller 5500PACA. Installation Instructions

Transcription:

Product Bulletin VeriSafe Absence of Voltage The Safe Way to Verify the Absence of Voltage. When servicing electrical equipment, workers must comply with safety regulations that require a voltage verification test to validate the absence of voltage. This process includes a number of stages that can be complex and time-consuming when using hand-held portable test instruments. The patent-pending VeriSafe Absence of Voltage from Panduit simplifies this process by automating the voltage verification process. Once installed, a simple push of a button enables qualified electrical workers to verify the absence of voltage and see an active indication when the absence of voltage is confirmed. This provides a new and innovative way to safely, reliably, and efficiently verify the absence of voltage before accessing potentially dangerous electrical equipment. By automating this process, the VeriSafe Absence of Voltage Reduces the risk of exposure of electrical hazards for improved worker safety Reduces testing procedure time and complexity to improve productivity Supports compliance when used as part of the lockout/tagout process described in NFPA 70E The VeriSafe Absence of Voltage minimizes risk by verifying the absence of voltage before equipment is accessed, making it easier for qualified electrical workers to determine an electrically safe environment in a fraction of the time compared to hand-held portable test instruments. Key Features Improved Safety & Risk Reduction Increased Productivity Simplified Process for Easier Compliance Reliable Results Flexible Applications Benefits Determine voltage status BEFORE equipment is accessed Prevents direct exposure to electrical hazards Easy to use, initiate test with the push of a button No additional tools required Provides visual alert to abnormal power conditions Automated test sequence based on the steps in NFPA 70E for verification of an electrically safe work condition Automated test helps reduce operator errors Fail-safe design with active indications Safety functions meet SIL 3 per IEC 61508-1 Designed for testing three-phase circuits up to 600V Install on line or load side of electrical disconnect Detects absence of AC and DC voltage

Electrical Safety Prior to performing de-energized work on electrical equipment, NFPA 70E requires that workers verify equipment is in an electrically safe state. Until proven otherwise, equipment must be treated as energized and necessary precautions must be observed. One of the steps in the process of verifying that equipment is in an electrically safe state involves a test for the absence of voltage. Verifying the Absence of Voltage Before and after testing, the functionality of the tester must be verified on a known source. When using a portable tester, this is a time-consuming process and may involve exposure to electrical hazards. Using the VeriSafe Absence of Voltage reduces risk and ensures the entire process is performed in the proper sequence every time, every test. Comparison of VeriSafe Absence of Voltage and Portable Device Testing Methods Portable s Select Test the Check for Voltage Retest the Perform Work Possible Exposure to Electrical Hazards VeriSafe Absence of Voltage Activate the VeriSafe Absence of Voltage Test the Verify Installation Check for Voltage Verify Installation Retest the Open Panel Automatically Performed in Sequence No Exposure to Electrical Hazards 2

More than a Voltage Indicator Voltage indicators warn of hazardous voltage, but cannot be used to confirm if equipment is de-energized. Absence of voltage testers are permanently-mounted test devices designed to verify that a circuit is de-energized prior to opening an electrical enclosure containing electrical conductors and circuit parts. RED indicators illuminate when hazardous AC voltage is present. When voltage is not detected, indicators are not illuminated. Pressing the TEST button initiates the voltage test, indicated by the flashing yellow voltage symbol. GREEN indicator illuminates only when the absence of voltage has been verified. L1 L3 L1 L3 L1 L3 L1 L3 Upstream Power: ON Upstream Power: OFF Upstream Power: OFF Upstream Power: OFF Absence of Voltage s are Fail-Safe and Reliable Test each phase conductor or circuit part phase-to-phase and phase-to-ground for absence of voltage Built-in test circuit verifies operation on a known voltage source before and after absence of voltage test Verifies installation of hardwired test leads before and after absence of voltage test Functional safety principles ensure hardware and firmware are designed to prevent and control dangerous failures of safety functions Installed device ensures tester is rated for the application and is less susceptible to damage than portable testers Automated test sequence helps reduces operator errors 3

System Components 1 Indicator Module 30mm knockout, mount on exterior of enclosure Operate and maintain without exposure to electrical hazards Instruction label with operating instructions 2 AVT System Cable Connects Isolation Module to Indicator Module 600V cable available in multiple lengths for easy installation Replaceable with connectors on each end 3 Isolation Module Prevents hazardous voltage from reaching door Universal mounting (DIN rail or surface tabs) Output contacts provide ability to create alarms or communicate with other systems 2 4 Sensor Leads Can be installed on line or load side of electrical disconnect 2 leads per phase; must be physically separated from each other Simple Battery Replacement Long-life industrial battery Replaceable from outside the enclosure No tools required 4

1 3 4 1 Instruction Label 5

Dimensions* Indicator Module 4.67 [119] Ø 1.913 [48.6] 0.080 [2.0] PANEL KNOCKOUT 0.180 [4.6] 1.54 [39] Ø 1.201 [30.5] Isolation Module 3.96 [100.6] 3.31 [84.1] 1.57 [39.8] 1.29 [32.9] 1.51 [38.4] 3.46 [87.9] 3.68 [93.5] Schematic Three-Phase Delta Three-Phase Wye BROWN L1 BROWN L1 MAIN FEED ORANGE YELLOW L3 NEUTRAL ORANGE YELLOW L3 INDICATOR MODULE L1 ISOLATION MODULE L3 GND GREEN/YELLOW STRIPE EARTH INDICATOR MODULE L1 ISOLATION MODULE L3 GND GREEN/YELLOW STRIPE EARTH Warning: The AVT must be installed correctly and grounded as described in the installation instructions to provide proper indication of absence of voltage. Sensor leads, including ground, must not be mechanically connected to each other in order for the device to verify connection to the circuit. 6 *Dimensions in inches [millimeters].

Voltage Verification System Ordering Information VeriSafe Absence of Voltage Part Number Part Description VeriSafe Absence of Voltage s VS-AVT-C02-L10 VeriSafe Absence of Voltage with 2 ft. system cable, 10 ft. sensor leads. VS-AVT-C08-L10 VeriSafe Absence of Voltage with 8 ft. system cable, 10 ft. sensor leads. Accessories VS-AVT-CABLE-02 VeriSafe Replacement Cable, 2 ft. VS-AVT-CABLE-08 VeriSafe Replacement Cable, 8 ft. Sensor Lead Connection Kits VS-CK10-8 VeriSafe Connection Kit for Tapping 10 to 8 AWG conductors. VS-CK8-6 VeriSafe Connection Kit for Tapping 8 to 6 AWG conductors. VS-CK6-2 VeriSafe Connection Kit for Tapping 6 to 2 AWG conductors. VS-CK1-00 VeriSafe Connection Kit for Tapping 1 to 2/0 AWG conductors. Equipment Retrofit Kits VS-AVT-RK1 Complete kit to retrofit equipment with VeriSafe Absence of Voltage. Includes AVT device with 10 ft. sensor leads, 2 ft. and 8 ft. system cable, connection kit 10 8 AWG power connectors, (3) cable ties, (3) cable ties mounts, (3) wire markers. VS-AVT-RK2 Complete kit to retrofit equipment with VeriSafe Absence of Voltage. Includes AVT device with 10 ft. sensor leads, 2 ft. and 8 ft. system cable, connection kit 8 6 AWG power connectors, (3) cable ties, (3) cable ties mounts, (3) wire markers. VS-AVT-RK3 Complete kit to retrofit equipment with VeriSafe Absence of Voltage. Includes AVT device with 10ft. sensor leads, 2 ft. and 8 ft. system cable, connection kit 6 2 AWG power connectors, (3) cable ties, (3) cable ties mounts, (3) wire markers. VS-AVT-RK4 Complete kit to retrofit equipment with VeriSafe Absence of Voltage. Includes AVT device with 10 ft. sensor leads, 2 ft. and 8 ft. system cable, connection kit 1 2/0 AWG power connectors, (3) cable ties, (3) cable ties mounts, (3) wire markers. Technical Specifications Applications Electrical System For use in 1, 2 or 3-phase AC systems Voltage Detection Range Up to 600V AC (50/60Hz), 600V DC Absence of Voltage Threshold 3 V Overvoltage Category III (600 V) Degree of Protection NEMA 1, 12, 4, 4X / IP66* Environment Operating Temperature 0 C to + 60 C (32 F to 140 F) Storage Temperature -45 C to + 85 C (-49 F to +185 F) Humidity 5 to 95% non-condensing Pollution Degree 3 Battery Voltage Industrial 3.6V Lithium AA Estimated Life User replaceable. Estimate 5+ years with normal operating conditions. Standards UL 1436 Standard for outlet circuit testers and similar indicating devices. EN/CSA/UL 61010-1 Safety requirements for electrical equipment for measurement, control, and laboratory use. EN/CSA/UL 61010-2-030 Safety requirements for electrical equipment for measurement, control, and laboratory use Part 2-030: Particular requirements for testing and measuring circuits. UL 508 & CSA-C22.2 No. 14 Industrial control equipment. IEC 61508 Functional safety, SIL 3. FCC CFR 47 Part 15 Radio frequency devices. EN 61326 & EN 55011/CISPR 11 EMC standards for industrial measurement products. CAN ICES-1 Industrial, Scientific and Medical (ISM) radio frequency generators. CERTIFICATIONS** UL, cul, CE, RoHS *Degree of protection specified is related to the Indicator Module only. ** Pending. 7

Related Products and Services Safety Products Devices Panduit has a line of versatile and innovative Lockout/Tagout devices, tags, and safety padlocks to isolate and lockout energy sources. Identification Panduit has a broad array of identification products, including preprinted, custom preprinted and print-on-demand solutions. Solutions for identification of Lockout/Tagout areas, identification of Arc Flash hazards, and required personal protective equipment (PPE). Safety Services Lockout/Tagout Safety Service Panduit offers a turn-key service to develop machine-specific procedures for any industrial machine or facilities equipment. This service consists of three phases: on-site assessment, design and implementation of LOTO procedures. Arc Flash Safety Service Panduit offers a turn-key service to assess, calculate and implement specific electrical hazard labeling that is compliant with NFPA 70E and CSA-Z462. Safety Training Professional Training Panduit removes the guesswork and provides instructor-led, on-site safety training that is customized, concise, and understandable. This includes: Lockout/Tagout Training Electrical Safe Work Practice One-Day Training Training Resources Panduit provides many training resources, including: A Life is on the Line DVD Lockout/Tagout Training Kit Electrical Safety Whitepaper WORLDWIDE SUBSIDIARIES AND SALES OFFICES PANDUIT CANADA Markham, Ontario cs-cdn@panduit.com Phone: 800.777.3300 PANDUIT EUROPE LTD. London, UK cs-emea@panduit.com Phone: 44.20.8601.7200 PANDUIT SINGAPORE PTE. LTD. Republic of Singapore cs-ap@panduit.com Phone: 65.6305.7575 PANDUIT JAPAN Tokyo, Japan cs-japan@panduit.com Phone: 81.3.6863.6000 PANDUIT LATIN AMERICA Guadalajara, Mexico cs-la@panduit.com Phone: 52.33.3777.6000 PANDUIT AUSTRALIA PTY. LTD. Victoria, Australia cs-aus@panduit.com Phone: 61.3.9794.9020 For more information Visit us at www.panduit.com Contact Customer Service by email: cs@panduit.com or by phone: 800-777-3300 2017 Panduit Corp. ALL RIGHTS RESERVED. Printed in the U.S.A. SFCB06--WW-ENG 3/2017