quality european heating appliances

Similar documents
I - WHERE TO INSTALL THE PANEL HEATER

Installation and Operating Manual

THERMOFILM CONVECTIVE PANEL HEATER INSTALLATION, OPERATION AND MAINTENANCE MANUAL. Models: CP 2400 CP 2000 CP 1500 CP 1000 TABLE OF CONTENTS

PRODUCT MANUAL OPERATION, INSTALLATION AND MAINTENANCE MANUAL. Indoor Convective Panel Heater

Models: RP-10, RP-15, RP-20. User Manual

Colorado SCR. Electric Towel Radiator Operating and Installation Instructions. (Read these instructions carefully and retain for future reference)

ECOLEC PANEL HEATERS GENERAL NOTES.

AVANT DGS. Thermal Electric Radiator. Operating and Installation Instructions. (Read these instructions carefully and retain for future reference)

CDE2TI, CDE2TIB, CDE2ECC, CDE2ECCB, CDE24ECC & CDE24ECCB AUS/NZ

FAN HEATER FH118 User Manual

General Care and Safety Guide

Platinum Series Electronic Panel Heaters

Dear Customer. Contents. 1) Vantage Electric Radiator characteristics Pag.3. 2) Technical specifications Pag.3. 3) Warnings Pag.4

Low Level Thermal Electric Radiator. Installation and Operation Guide. Models. Type Wattage No. of Fins Size (HxWxD) (mm) Net Weight (kg)

Operating Instructions. Oil Column Heater. Models: GOC155, GOC157, GOC1511

Installation and user manual

200W Frostwatch Radiant Heater Operation Manual

PANEL HEATERS OPERATING INSTRUCTIONS

Electronic Ceramic Tower Heater

AC500T, AC1000T, AC1500T, AC2000T

Ceramic Wall Heater With Remote

Contact Details. Please note that some of the contact details on this PDF document may not be current.

Clima Infrared Radiant & Convection Panel

PANEL HEATER OPERATING INSTRUCTIONS. For Models: CELEPANEL, CELEPANELT

HYDROTHERM FLOOR TO CEILING - SERIES

Serene Classic Rails

General Care and Safety Guide

ENGLISH INSTRUCTION MANUAL PLM 9KE-410 /12KE-410 /15KE-410 PLUS HEATER VERSIONS

Girona. Operating Instructions. Glass Panel Heaters. Models: GFP050 W/B GFP075 W/B GFP100 W/B GFP150 W/B GFP200 W/B. A world of expertise

INSTRUCTIONS. Family 4 N 4062 Issue C Date 01/2011. CMV Certification reference NF205.

The Vitro-i. Radiant / Convector Combination Heater. Instructions for Operation and Installation

TF1800 Thermofan Installation Guide YOUR STEP-BY-STEP GUIDE TO THE PERFECT INSTALLATION

Imperial Electric Fires

PANEL HEATER OPERATING INSTRUCTIONS. For Model: CELEPANELD

HAVERLAND APP. The first self-programmable radiator and control from anywhere in the world INSTRUCTION MANUAL.

2.9kW Portable Air Conditioner

3KW ELECTRIC FAN HEATER

Convection Panel Heater

2000W Ceramic Wall Heater with LED Display

Model 1174 Electric Heater User instructions for LED effect 2kw Inset Heater

15KW ELECTRIC FAN HEATER

Operating Instructions

Mobile Evaporative Cooler EVA-12

20L Electronic Dehumidifier

2.4kW Ceramic Heater Model: DHCER24SW

Noirot Spot Plus Digital Timer

30KW ELECTRIC FAN HEATER

ONE. User Manual. Heating Element and Electric Radiator

AP24MT, AP24ET, AP15ET, AP10ET. Convection Panel Heaters. Instruction Manual

2.8KW ELECTRIC FAN HEATER

Important Notes: Please read carefully before installing your refrigerator.

5KW ELECTRIC FAN HEATER

Installation Instructions & Operating Manual IMPORTANT

User Instructions for Remote Controlled 2kW Rotisserie Effect Fan Heater Model 1276

PANEL HEATER OPERATING INSTRUCTIONS. For Models: TWFP10000, TWFP PK

NEXIUN ANALOGUE INERTIA RADIATOR, PROGRAMMABLE WITH PILOT WIRE INSTALLATION INSTRUCTIONS AND USER GUIDE NEX4PW NEX8PW NEX12PW NEX14PW

15,000 BTU Portable Air Conditioner

INSTALLATION AND MAINTENANCE MANUAL BLITZ FD_

Mobile Air Conditioner Instruction Manual Model TC-N9KM

General Care and Safety Guide

2200W RADIANT HEATER GVARH350. Instruction Manual

1500W CERAMIC HEATER. Instruction Manual

2.9kW Portable Air Conditioner

30L Mini Oven with Twin Hotplates. Model: MA0080MO READ AND FOLLOW THESE INSTRUCTIONS. RETAIN FOR FUTURE REFERENCE

Radiant Heater. Instruction Manual QH-200 N13275

INSTALLATION & USER INSTRUCTIONS

User Manual. Electric Heating Element MEG DRY MOA REG 2 REG 3

EDGE PATIO HEATER. User Manual. English

INSTALLATION & USER INSTRUCTIONS

PRACTICAL USER S GUIDE FOR THE DIMPLEX ELECTRIC FIREPLACE WITH REMOTE CONTROL

2kW UPRIGHT FAN HEATER INSTRUCTIONS FOR USE

INSTRUCTION MANUAL FOR ELECTRIC RADIANT INFRARED HEATERS

8L DEHUMIDIFIER OPERATING INSTRUCTIONS

QUALITY SPACE HEATERS

Curv-infrared.com. The Smarter Way. To Heat Your Home. Installation & Operating Instructions For Cürv, Flat, Towel Rail and Mirror Infrared Heaters

INSTALLATION & USER INSTRUCTIONS

Optimax Refrigerated Retail Merchandisers

Installation & Operating Instructions. Models: Desire, Ignite & Hereford Electric Stoves

80cm Tower Fan With Remote Control

12L DEHUMIDIFIER OPERATING INSTRUCTIONS

IMPORTANT SAFETY INFORMATION:

CERAMIC HEATER MODEL NO: DEVIL 350B 230V/110V OPERATING & MAINTENANCE INSTRUCTIONS PART NO: & ORIGINAL INSTRUCTIONS GC ISS 1

Installation & Operating Instructions. Models: York Midi & Serrano Electric Stoves

Optima S2055/6. Wall Mount Space Heater with Cooling Fan. Installation and Operating Manual

Product & Assembly Manual

INSTALLATION AND MAINTENANCE MANUAL. Alcor FA

Contents. References for your electric towel-dryer radiator 2. Warning 3

IMPORTANT SAFETY INFORMATION:

/ De Longhi Appliances via Seitz, Treviso Italia

2400W Ceramic Tower Heater

R A D I A N T O U T D O O R H E A T E R S OPERATION, INSTALLATION AND MAINTENANCE MANUAL. TT-MTM Wall Controller

OFC1000, OFC1500, OFC2000, OFC2500 OFC1000TI, OFC1500TI, OFC2000TI & OFC2500TI

INDEX WARNINGS AND RECOMMENDATIONS 2 COMPLIANCE DECLARATIONS 3 RANGE AND SIZES 3 ELECTRICITY SUPPLY 3 INSTALLATION 4 INSTRUCTIONS FOR UNINSTALLING

Motion tracking. sensor led light. Installation & operating manual NIGHTWATCHER. Model no: nw1200x

Lucci Designer Hi Flow Exhaust Fan

AVANT DGi. Thermal Electric Radiator. Operating and Installation Instructions. (Read these instructions carefully and retain for future reference)

Imperial Electric Fires

OWNER S MANUAL. Convair Tower Heater CTH09. (English) (CTH09)

Saletto. Operating Instructions. Low Profile Panel Heaters Models: LPP050 LPP075 LPP100 LPP150. A world of expertise

/04.14_00. De Longhi Appliances via Seitz, Treviso Italia

Transcription:

Superb Comfort in every room of your home quality european heating appliances AUSTRALIA Ph:03 9852 9599 www.atlantics.com.au ss@atlantics.com.au S4/13-25 Church Street Hawthorn 3122 Victoria Australia NEW ZEALAND Ph:0800 422 000 www.atlantics.co.nz sales@atlantics.co.nz

PASS PROGRAM HEATERS - MODULAR TECHNOLOGY Wattage Width Height Depth Room Code (mm) (mm) (mm) (m2) Standard 1000 445 450 78 10 516913 1500 590 450 78 15 519617 2000 740 450 78 20 519622 2400 890 450 78 24 519627 Low 1000 665 340 78 10 519912 1500 890 340 78 15 519917 2000 1035 340 78 20 519922 High 1000 370 670 78 10 519412 1500 520 670 78 15 519417 2000 665 670 78 20 519422 Plinth 500 665 250 78 5 519507 1250 1185 250 78 13 519513 MODULAR ADD ONS Castors 572000 Timer 602019 1 Zone Wall Switch 602007 BATHROOM HEATERS Wattage Width Height Depth Code (mm) (mm) (mm) Tatou Bath 1000 470 775 95 516410 1500 470 1070 95 516415 Doris Chrome 300 500 915 85 950103 500 500 1360 85 950105 Nefertiti Electric 500 550 1167 137 850005 750 550 1436 137 850007 Electric 500 550 1167 137 850015 1000w fan 750 550 1436 137 850017 Electric 500 550 1167 137 851015 1000w fan 750 550 1436 137 851017 Hydronic

1 2 3 4 5 Feet and castors not to be fitted on high end plinth models Diagram corresponding to high version 500W 6 8 7 9

The product you have just purchased has undergone numerous tests and inspections to guarantee the highest quality. We hope it will give you entire satisfaction. INSTALLATION OF THE PANEL HEATER Please read the instructions before starting to install the heater. Disconnect the power before carrying out any work on the heater. Keep these instructions even once you have installed your heater. 1) Where to install your heater? - This equipment was designed to be installed in a residence. Please ask your distributor before using it for any other purpose. - The panel heater should be installed according to normal trade practice and in compliance with legislation in the relevant country (the IEE Wiring Regulations). - The equipment is class 2 and is protected against splashed water IP 24. Therefore it can be installed in volume 2, provided the panel heater s controls cannot be reached by a person using the shower or bath. 1 - Comply with the minimum clearance distances for positioning of the panel heater. 2 - If your wall covering is laid on foam, a spacer the same thickness as the foam must be placed under the panel heater s support. This ensures there is free space behind the panel heater to make sure its control settings are not adversely affected. - Do not install the panel heater: In a draught likely to affect the control settings (under a fan, etc.). Under a fixed mains power socket. Except in the UK. Please refer to the IEE Regulations 601-06-01 and 601-08-01 (BS7671). It is strongly recomended not to install vertical products we manufacture above an altitude of 1000 metres. If the device is installed at altitude the air discharge temperature will be increased (by approximately 10 C per 1000 m of altitude). It is forbiden to install vertical product in horizontal position. 2) How to install the panel heater? 2-1) Mount the wall support A : Standard and high version 346 B : Plinth and Low version 78 - Mount the panel heater on mounting S as shown. Lock the lock V. 4 Note : Do not use the device in mobile or feets or on casters 5, except the range kit feet (ref. 417010-417015 - 417020) and Australian ranges : Standard and Low. 2-2) Connecting the panel heater - The panel heater must be powered with 220-240V 50Hz - The panel heater must be connected to the mains, either by a 2-wire cable (Brown = Phase, Blue = Neutral) via a power socket. In humid areas such as bathrooms and kitchens the power socket must be installed at least 25 cm above the floor. - The installation must be equipped with a omnipole disconnexion mechanism with a break contact distance of at least 3mm. - Earthing is prohibited. Do not connect the pilot wire (black) to earth. - The heater must be installed by a qualified electrician in accordance with the local regulations. The heater and the pilot wire (black) must NOT be connected to earth. If the heater wire is damaged, it must be replaced by a qualified person to avoid hazard. If a pilot or piloted panel heater is protected by 30mA differential (e.g. bathroom) the pilot wire s power must be protected on this differential. Commands received No current Complete alternation 230 V Négative half-alternatio n - 115 V Positive half-alternatio n + 115 V Oscilloscope s Réf/Neutr al Mode obtained COMFORT ECO ANTI-FREEZ E POWER CUT STOP

USING THE PANEL HEATER 1) Description of the control unit : 9 ➊ Mode cursor. ➋ Temperature adjustment control knob. V1 Heating indicator light 2) Fixing the comfort temperature The comfort temperature is the temperature that you would like while the room is occupied. a) Put the ➊ cursor to. b) Set the ➋ control knob on 5, the heating indicator V1 comes on if the room temperature is below the required temperature. c) Wait a few hours for the temperature to stabilise. d) If the setting is satisfactory (if necessary use a thermometer to check), mark the position for future use. e) If the setting is not satisfactory, adjust it and start again from point c. 3) Fixing the Eco temperature : This is the required temperature during periods when the room is unoccupied. It is recommended that this mode should be used if the room is unoccupied for no more than 2 hours. a) Set the to. b) This will reduce the temperature of the thermostat by 3 C to 4 C from 2 setting. The heating light V1 comes on, if the ambient temperature is lower than the Eco temperature. c) Wait a few hours until the temperature stabilizes. Note : When switching n 1 (on the picture) is set on Programming system (clock symbol) with the PassProgram On/Off, please refer to paragraph n 8. 4) Frost-Free mode This mode is used to keep the temperature at approximately 7 C in the room when you are absent from the house for a prolonged period (i.e. more than 24 hours). a) Set the ➊ switch on. 5) The heating indicator : V1 This light comes on when the heating element is working. It may flash when the temperature has stabilised. 6) Locking the controls : It is possible to lock or limit use of the ➋ control knob and lock the ➊ switch to prevent unauthorised manipulation of the panel heater (children, etc.). a) Unhook the panel heater from its wall mounting. b) Remove the slugs P on the back of the thermostat from their mountings. c) Select position B to lock the control knob or position L to limit the amount it can be turned. Position M blocks the switch for Electronic Model. 7) Using the pilote wire : The product with pilote wire can receive the following signals from a master unit : - comfort (temperature of (2) control knob) - eco (comfort temperature -3 C to -4 C) - frost free (approximately 7 C) - off. Put the switch (1) to the programming mode (clock symbol). The product must be connected through the pilote wire to a programming control or a product equipped with pass program system in order to use these different modes. You can control several convectors with a single programmer or a product equipped with pass program system. Warning: When the programme turns to Frost Free or Off in the main programming system or using a Pass Program system, these functions will override the manual switch of the Panel Heater. 8) Using the On/Off PassProgram system. Ref 602019 When using programming mode (clock symbol) with the on/off pass program system (interface + timer), the moon symbol on the timer refers to the off mode (no heating). Warning: When the programme turns to Off using a Pass Program system (ref. 602019), this function will override the manual switch of the Panel Heater. RECOMMENDATIONS FOR USE - There is no point in setting maximum heating, the room temperature will not rise any quicker. - When you air the room, disconnect the panel heater by putting the switch to off. - If you leave for several hours, remember to reduce the temperature. Absence for: less than 2 hours, set the cursor switch knob to moon. 2 to 24 hours, put the control Knob to or off. - If you have several units in a room, let them operate simultaneously. This will give you a more uniform temperature without increasing electricity consumption.

WARNINGS This appliance is not for use by young children or infirm persons unless they have been adequately supervised by a responsible person to ensure that they can use the appliance safely. Young children should be supervised to ensure that they do not play with the appliance, lean against the front or insert objects or paper in it. Do not totally or partially block the grilles on the front or inside of the appliance, as this may cause overheating. If the supply cord is damaged, it must be replaced by a service agent or similarly qualified person in order to avoid a hazard (applies to units fitted with a supply cord and plug). Units fitted with a three core supply cord (brown, blue & black), must be directly connected to fixed wiring by a licensed electrician. All work on the interior of the appliance must be carried out by a licensed electrician. MAINTENANCE To maintain performances of your unit, you should clean the upper and lower grilles of the unit about twice a year using a vacuum cleaner or a brush. Have a professional check the inside of the unit every five years. Dirt may collect on the grille of the unit if the atmosphere is polluted. This phenomenon is due to the poor quality of the ambient air. In this case, it is recommended to check that the room is well ventilated (ventilation, air inlet, etc.), and that the air is clean. The unit will not be replaced under the guarantee because of this type of dirt. The unit casing should be cleaned with a damp cloth, never use abrasive products. TROUBLE-SHOOTING If the unit does not heat : Check that the programmer is in COMFORT mode (electronical). Make sure that the installation circuit breakers are switched on, or that the load shedder (if you have one) has not switched off the unit power supply. Check the air temperature in the room. The unit does not carry out programming orders : (version with pilot wire) Make sure that the programming unit is being correctly used (refer to its user s manual) or that the Chronopass is properly inserted in its housing and that it is operating normally (batteries?). The unit is permanently heating : Make sure that it is not in a draft and that the temperature setting has not been changed. This unit with electronic control is equipped with a microprocessor that can be distribued by some severe mains voltage disturbances (outside EC standards defining the disturbance protection level). If there are any problems (thermostat blocked, etc.) switch off the unit power supply (fuse, circuit breaker, etc.) for about 5 minutes to allow the unit to start again. Have your energy distributor check your power supply if the phenomenon occurs frequently. WARRANTY CONDITIONS : KEEP THIS DOCUMENT IN A SAFE PLACE (This certificate should only be produced if you are making a complaint, attached with the invoice of the purchase) - This guarantee is applicable for 2 years from the date of original purchase and shall be valid for no more than 30 months from the date of manufacture. - Your Atlantic distributor will exchange parts shown to be defective in manufacture. The replacement parts will be of charge but Atlantic does not accept responsability for freight or labor charges or losses in transit. - This guaranteeexcludes damage by neglect, shipping or accident and any damage due to incorrect installation, use or purposes other than those intended or failure to observe the instructions given. UNIT TYPE * : SERIAL NUMBER * : CUSTOMER S NAME AND ADRESS : * This information is shown on the plate which can be seen on the left-side or behind the front grille of the unit. FOR SALES IN NEW ZEALAND ATLANTIC AUSTRALASIA - Phone : 0800 422 000 - Fax : 04 3800 509 INSTALLER S STAMP FOR SALES IN AUSTRALIA ATLANTIC AUSTRALASIA PTY LTD 4/13-25 Church Street Hawthorn Victoria 3122 Australia Free call : 1800 677 857 Phone : 03 9852 9599 Fax : 03 9852 9844 web : www.atlantics.com.au

MODULAR TECHNOLOGY Pass Program Heaters Stylish and innovative, Atlantic heaters are renowned for superb warmth and comfort. They now incorporate new modular technology for greater flexibility. You can start with one panel, adding heaters and timers as required. Perfect for all rooms, as they are dust free and do not alter the relative humidity levels. Panels can either be wall mounted or free standing. Atlantic Products are silent and all electric. They come with wallbrackets for easy installation. Other features include double installation, splash proof design,childproof controls and safe surface temperatures. All Atlantic products can be interconnected and fully programmed as a central heating system. Selecting Heater Size Multiply width x length of room to get square metres (m 2 ). Eg. length 3m x width 3m = 9m 2. 100 watts x 9m 2 = 900 watts. This would require a 1000 watt heater, ideal for smaller rooms. Living & Bedroom: Allow 100 watts per m 2 of room area with a ceiling height of up to 3m. For example, a 15m 2 area requires a 1500 watt heater. Bathroom: Allow 200 watts per m 2 of bathroom area. For example, a 5m 2 area requires a 1000 watt heater. Running costs for Room Heaters Based on a 1000 watt heater, if the electricity tariff is 14 cents Kw/Hr it will cost 14 cents per hour to operate. If the panel is sized correctly for the room the electronic thermostat will monitor the room temperature every 40 seconds. This creates a running cycle of 50% once the desired temperature is reached. Effectively an Atlantic 1000 watt panel heater will cost approximately 7 cents per hour to run, saving running costs by half. Under these conditions Atlantic panel heaters can cost from approximately 7 cents per hour for a 1000 watt heater, to an economical 17 cents per hour for the larger 2400 watt heater. *Running costs will vary depending on conditions such as insulation, curtains, and room size. For effective heating, rooms should be fully insulated, preferably with curtains and floor coverings. All doors should be closed.

Tatou Bath The Tatou Bath is a true radiant heater, you can feel its luxurious warmth radiating into the bathroom. The Tatou Bath range is available in two sizes, 1000 watt or 1500 watt. This heater also features an anti-corrosion frame for long life. An optional timer is available to save on running costs. Pass Program Plinth The Plinth model is an ideal way to warm your bathroom and dry the towels. It is available in a 500 or 1250 watt unit. Simply fix it to your wall, under your towel rail and plug in to a power point. Nefertiti Not only does the Nefertiti dry towels rapidly but features a powerful 1000 watt room heater with air filter for added comfort. Available in 3 different models: with fan, without fan or as a hydronic model. Towels and fabrics slide easily in from the side and a push button timer controls drying time. Doris Chrome For luxurious, warm towels and a cosy bathroom install the Doris Chrome. It not only dries your towels, but warms your bathroom as well. In addition, a two hour push-button timer saves on running costs compared to other units that run continuously. 12-80-1182/A