Please read operating instructions carefully before use and keep it for further reference.

Similar documents
Read the operating instructions carefully before use and keep for future reference.

WARNING CAUTION. Approval Marks. Protection Class Ι TECHNICAL DATA. CCA certified

WARNING CAUTION. Approval Marks. Protection Class I TECHNICAL DATA. CCA certified

Please read operating instructions carefully before use and keep it for further reference.

OPERATING INSTRUCTIONS. LEISTER Drive

Please read operating instructions carefully before use and keep it for further reference.

Please read operating instructions carefully before use and keep for further reference.

OPERATING INSTRUCTIONS

Please read operating instructions carefully before use and keep for further reference.

LHS PREMIUM LHS SYSTEM

Portable Banner Welder JC-2000-GM User Manual

OPERATING MANUAL. BAK Thermoplastic Welding Technology AG 1

OPERATING MANUAL. BAK Thermoplastic Welding Technology AG 1

OPERATING INSTRUCTIONS. Automatic welding machine LARON Version 2.1

Air heaters are modular units which create process heat in industrial environments.

S-LINE OVAL-LINE Handschweissgeräte

S-LINE Hand-held Handschweissgeräte

2.8KW ELECTRIC FAN HEATER

30KW ELECTRIC FAN HEATER

Use and maintenance Manual Longitudinal profile welding Model: LRW-130

SAFETY AND OPERATING MANUAL. Original Instructions 5.0

Combivac Operating Instructions Combivac

TOOLS The Best Choice in Hot Air Tools

3KW ELECTRIC FAN HEATER

15KW ELECTRIC FAN HEATER

5KW ELECTRIC FAN HEATER

User Manual GV25 GV35 GV702. Company information: Original instructions GV12066 (1)

INFRARED IP55 HEATER INSTRUCTIONS FOR: MODEL:- QZWP45N 1. SAFETY INSTRUCTIONS

Read through the instructions carefully before using the appliance for the first time. Safeguard them for future reference.

Blower UB1100 UB1101 INSTRUCTION MANUAL

HG-2000E HEAT GUN WATTS

Steam Mop Instructions for Use

PANEL RADIATOR. USER MANUAL HSDOnline.co.uk 2KW OIL FILLED POH04

High Pressure Washer - SAFETY INSTRUCTIONS

INDUSTRIAL VACUUM CLEANER WITH AUTO START/STOP

S115 INSTRUCTION MANUAL

OWNER S MANUAL LG CORDLESS VACUUM CLEANER

TTV 4500 / TTV 4500 HP / TTV 7000

TOOLS. The Best Choice in Hot Air Tools

INSTRUCTION MANUAL Soldering Station Ref. LC-2SIA

Read this manual through carefully before installing/using the cleaner, paying special attention to the SAFETY INSTRUCTIONS

Models: RP-10, RP-15, RP-20. User Manual

Local Air Conditioner

OPERATING MANUAL ORWAK March 2005 PUBL. NO Edition 4

TDS 20 R / TDS 30 R / TDS 50 R

40cm Wall Fan With Pull Cord Operation

Drying Cabinet Installation and Operating Manual

EVAPORATIVE AIR COOLER SERVICE MANUAL

Hot Air Station Ref. JT-B

INSTRUCTIONS AND WARRANTY

Commercial backpack vacuum cleaner

C E B D N USER MANUAL H I P J K L /07 PRINTED IN P.R.C.

Operating Instructions

INSTRUCTIONS AND WARRANTY

SMD Rework Station TABLE OF CONTENTS

INSTRUCTIONS FOR SAFE USE INSTRUCTIONS FOR SAFE USE

WET & DRY GARAGE VAC 20L CAPACITY WATT 1.5M MOTOR TANK STEEL HOSE KP702 ON BOARD ACCESSORY STORAGE SUCTION STAINLESS

TIH 300 S / TIH 400 S / TIH 500 S / TIH 700 S / TIH 900 S / TIH 1100 S

A INSTRUCTIONS FOR USE

11. Please follow cleaning instructions carefully so as to avoid injury or damage. 12. Should the Fan or protection fuse fail to work properly, turn

Your Blast Vac Pro. Your Blast Vac Pro

Operating Instructions ERSA IR 500 A SMT / BGA Rework System 3BA

Vacuum cleaner Instruction manual

Register your new Bosch now:

Installation Electric Dryers Instructions 01

Industrial steam lron. Silver Steamer USER MANUAL

GENANO AIR PURIFICATION TECHNOLOGY

INSTRUCTIONS AND WARRANTY

O INSTRUCTION MANUAL P V* S N W* J F X* E R L** M** A Y* PRINTED IN P.R.C

51AKB / 51 AKC OWNER S MANUAL

DR12, DR16, PO4, PO4+4

Premium Micro Desoldering station

R32. Installation Manual Split Type Wall Mounted Air Conditioner. This appliance shall be installed in accordance with: REFRIGERANT

SHORT WAVE INFRARED PANEL DRYER

High-Pressure Washer BY02-VBP-WTR BY02-VBP-WTH. CAUTION : Do not use this device before reading the instructions.

Technical Data. Name: ERIKA Automat fully automatic machine to divide and to round dough pieces of the same size

Bar Fridge USER MANUAL MB46W

SAFETY, OPERATION AND MAINTENANCE MANUAL. MX-1408 SELF-CONTAINED EXTRACTOR This unit is intended for commercial use.

DUST EXTRACTOR INSTRUCTION MANUAL. 550W (3/4 HP) INDUCTION MOTOR 1850W AUTOMATIC POWER OUTLET 65L COLLECTION BAG ø100mm X 2.

ENGLISH (Original instructions) INSTRUCTION MANUAL. Belt Sander DOUBLE INSULATION. IMPORTANT: Read Before Using.

INSTRUCTION MANUAL 1

Built in Electric Ceramic Hob. Instruction Manual

Electric Powerhead Owners Manual

MTP (MTPAL) AIR HEATERS TECHNICAL DOCUMENTATION

7 Fin Oil Filled Radiator

Main switch Granules collecting device

O B H I J P E F R Q S T U V W

INSTRUCTIONS FOR USE - TUMBLE DRYER AWG 367

INSTRUCTIONS AND WARRANTY

Vax Ltd., Kingswood Road, Hampton Lovett, Droitwich, Worcestershire, WR9 OQH, UK - website: vax.co.uk. Version 1.

STEAM WALLPAPER STRIPPER MODEL HTW5

IMPORTANT SAFETY REMINDERS:

ONE. User Manual. Heating Element and Electric Radiator

U V S R2 W INSTRUCTION MANUAL ENGLISH G H PRINTED IN P.R.C /01

NT 70/1, 70/2, 70/3 Service Manual

INSTRUCTIONS AND WARRANTY

How to get the most from your Integrated Tumble Dryer HJA 8800

HOUSEHOLD FREEZER 048-GM-48303/048-GM-48304/048-GM-48305

INSTRUCTIONS FOR CARBON INFRARED HEATER

SPECIAL PRICE PROMOTION. WORKSHOP EQUIPMENT. CLEANING EQUIPMENT; WELDING RIG; WELDING SAFETY WALL.

Transcription:

GB OPERATING INSTRUCTIONS LEISTER Uniplan S / Unifloor S Automatic hot air welding machine Please read operating instructions carefully before use and keep it for further reference. APPLICATION LEISTER Uniplan S Automatic Overlap Welding Machine Overlap and tape welding of coated fabrics, foils and membranes made from PVC-P, PE, ECB, CSPE, EPDM, PVDF etc. as well as PE woven materials for truck covers, tents, covers for agriculture and construction, biotopes, swimming pools, awnings, boat covers, inflatable boats, billboards, banners. Welding seam width 0 or 30 mm LEISTER Unifloor S Automatic Flooring Welding Machine Welding of PVC coverings and melt welding of linoleum floor coverings. LEISTER Process Technologies, Riedstrasse, CH-6060 Sarnen/Switzerland Tel. + 1 1 66 7 7 Fax + 1 1 66 7 16 www.leister.com sales@leister.com 1

WARNING Danger! Unplug the tool before opening it, as live components and connections are exposed. Incorrect use of hot air tools can present a fire and explosion hazard, particularly in the proximity of flammable materials and explosive gases. Danger of getting burned! Do not touch the heater tube and nozzle when they are hot. Let the tool cool down. Do not point the hot air flow in the direction of people or animals. Only connect the tool to a receptacle outlet with protective earth conductor. Any disconnection of the protective earth conductor, in or outside the tool is dangerous! Only use extension lead with a protective earth conductor. CAUTION 30 10 FI The rated voltage stated on the tool must correspond with the mains voltage. For personal protection, we strongly recommend the tool to be connected to an RCCB (Residual Current Circuit Breaker) before using it on construction sites. The tool must be operated under supervision. Heat can ignite flammable materials which are not in view. Interference can impair the welding process when taking place in the vicinity of high-frequency installations. Protect the tool from damp and wet. Approval Marks 3 TECHNICAL DATA Voltage V~ Frequency Hz Capacity W Temperature C Air flow l/min. Drive speed m/min. Noise emission level L pa (db) Dimensions Uniplan S mm DimensionsUnifloor S mm Weight Uniplan S kg Weight Unifloor S kg Protection Class Ι 1 CCA certified 30 10 100 50 / 60 50 / 60 50 / 60 300 1800 1500 0 60 0 60 0 60 Max. 300 Max. 50 Max. 50 1.0 7.5 1.0 7.5 1.0 7.5 67 65 65 0 70 10 0 70 10 0 70 10 0 70 15 0 70 15 0 70 15 11.5 11.5 11.5 1.0 1.0 1.0 Mains voltage cannot be switched over

ACCESSORIES LEISTER Uniplan S Assembly of additional weight Fasten the additional weight holder () to the Uniplan S machine with cheese head screw M8 0 (3). Attach the additional weight () to the additional weight holder (). Additional weight accessories 3 ACCESSORIES LEISTER Unifloor S Operational condition: Accessories If the welding rod de-reeler (5) and lifting device (11) are available: Attach welding rod de-reeler (5) to the Unifloor S machine using cheese head screw M8 0 (6). Attach lifting device (11) using socket head cap scew M6 30 (7). Accessory Welding rod de-reeler Accessory Lifting device 5 6 8 7 3

TOOL DESCRIPTION Overlap 0/30 mm LEISTER Uniplan S 1 13 15 16 1 1 1 9 17 18 19 0 1 3 5 6 0 10 8 3 7 1 11 Main components 1. Housing/chassis. Mains cable 3. Hot air blower. Welding nozzle 5. Connection hose 6. Drive/pressure roller 7. Pressure belt 8. Guide roller 9. Drive roller 10. Steering roller 11. Lifting device 1. Air filter 13. Manual air valve Operating components 1. Lifting device lever 15. Drive switch 16. Potentiometer for welding speed 17. Air blower switch 18. Potentiometer for air temperature 19. Two stage switch for airflow 0. Swivel lever 1. Fuse T 1.0 A 30 V~ T 1. A 10 V~

OPERATION LEISTER Uniplan S Operating condition Check the nozzle s basic setting (see diagram). Connect the tool to the mains. The mains voltage must correspond with the voltage rating stated on the tool. Tool positioning Swivel hot air blower (3) using swivel lever (0) up to the stop. 6 Operate lifting device (11) by means of lifting device lever (1) so that drive/pressure roller (6) and drive roller (9) are at no-load. Position the automatic welding machine on the overlap of the material to be welded. The outside edge of drive/pressure roller (6) must line up with the overlap edge of the material to be welded. Activate lifting device (11) by means of lifting device lever (1) so that the automatic welder is ready to run. 0 50mm Welding parameters Set potentiometer for welding speed (16) to the required value. Set potentiometer for air flow (18) to the required value. Turn on air blower switch (17). Set the two stage switch for airflow (19) at setting 3 and heat up for about 5 minutes. Important: low voltage. If the maximum temperature is not reached, reduce the airflow by means of the manual air valve (13) and two stage switch for airflow (19). The contact pressure is effected through the weight of the automatic hot air welding machine itself. Use the additional weight accessory as required (see assembly of additional weight, page 3). Welding procedure Swivel the hot air blower (3) up to the stop using swivel lever (0) and at the same time turn on the drive switch (15) (the welding process starts). Supervise the welding process. As necessary correct the welding speed with the potentiometer (16). Lead the automatic welding machine by its chassis along the length of the overlap. When welding has finished, swing up the hot air blower (3) to the stop by means of the swivel lever (0). Switch off the drive switch (15). After completing welding work, set the potentiometer for air temperature (18) to zero, so that the hot air blower (3) cools down. Then turn off the air blower switch (17). Disconnect the tool from the mains. 1 mm 5

TOOL DESCRIPTION LEISTER Unifloor S 1 11 13 1 1 1 7 15 16 17 19 0 1 3 18 5 6 9 8 10 0 3 Main components 1. Housing. Mains cable 3. Hot air blower. Welding nozzle with cover 5. Connection hose 6. Welding rod pressure roller 7. Drive roller 8. Chassis 9. Wall switch-off 10. Support bracket 11. Manual air valve 1. Air filter Operating components 13. Drive switch 1. Potentiometer for welding speed 15. Air blower switch 16. Potentiometer for air temperature 17. Two stage switch for airflow 18. Swivel lever Steering equipment 19. Welding rod guide tube 0. Guide roller 1. Fuse T 1.0 A 30 V~ T 1. A 10 V~ Detail A Cover open Cover closed 6

OPERATION LEISTER Unifloor S Operating condition Check the nozzle setting: the nozzle must maintain a distance from the base material and the welding rod of about -3 mm. When welding linoleum, lower the cover on to the welding nozzle () (see Detail A:Page 6). Connect the tool to the mains. Tool positioning Swivel hot air blower (3) up to the stop using swivel lever (19). Position the automatic welding machine over the joint to be welded. Insert the welding rod through the welding rod guide tube (19), pull it under the welding rod pressure roller (6) and place it in the joint. The Guide roller (0) must run in the welding joint. Welding parameters Set potentiometer for welding speed (1) to the required value. Set potentiometer for air temperature (16) to the required value. Turn on the air blower switch (15), set the two stage switch for airflow (17) at setting 3 and heat up for about 5 minutes. Important: low voltage. If the maximum temperature is not reached, reduce the airflow by means of the manual air valve (11) and the two stage switch for air flow (17). The contact pressure is effected through the weight of the automatic hot air welding machine itself. Welding procedure Swivel hot air blower (3) up to the stop using swivel lever (18) and at the same time turn on the drive switch (13) (The welding process starts). Supervise the welding process: Guide roller (0) must run in the joint. The welding bead must be visible. If necessary adjust the welding parameters using the potentiometer (1). Wall switch-off (9) When contact is made with the wall, the drive and heater are switched off automatically. When welding is finished, swing up the hot air blower (3) to the stop by means of swivel lever (18). Switch off the drive switch (13). Cut off the welding rod. Re-position the automatic welding machine as necessary. After completing work, set potentiometer for air temperature (16) to zero so that hot air blower (3) cools down. Then turn off the air blower switch (15). Disconnect the tool from the mains. 7

BA Uniplan S / Unifloor S / 11.0/GB ACCESSORIES Only LEISTER accessories should be used. Additional weight with holder for Uniplan S Welding rod de-reeler for Unifloor S Lifting device for Unifloor S TRAINING LEISTER Process Technologies and their authorised Service Centres offer welding courses world-wide free of charge. MAINTENANCE Clean the tool's air filter (1) with a brush when dirty. Clean welding nozzle () with wire brush. Check mains cable () and plug for electrical and mechanical damage. SERVICE AND REPAIR Have your Service Centre check the motor brushes after about 1,000 hours of operation. Repairs have to be carried out by authorised LEISTER Service Centres only. They guarantee, within hours, a correct and reliable repair service using original spare parts in accordance with the circuit diagrams and spare parts lists. GUARANTEE AND LIABILITY Guarantee and liability are in accordance with the guarantee certificate as well as with the currently valid general business and sales conditions. LEISTER Process Technologies rejects any guarantee claims for tools which are not in their original condition. The tools must never be altered or changed. Technical data and specifications are subject to change without prior notice. Your authorized Service Centre is: LEISTER Process Technologies, Riedstrasse, CH-6060 Sarnen/Switzerland Tel. + 1 1 66 7 7 Fax + 1 1 66 7 16 www.leister.com sales@leister.com 8