NEMO A Split-system liquid chillers for indoor installation. Cooling Capacity: 5 26 kw

Similar documents
nemo a hp rcgroupairconditioning R410A

MULTIPLO PF Multifunction chillers for indoor installation. Cooling Capacity: kw Heating Capacity: kw

FRIGO SCREW CLA PLUS Packaged water cooled liquid chillers in A+ class energy efficiency for indoor installation. Cooling Capacity: kw

rcgroup.it Flooded evaporator Low noise Minimum starting current EER up to 5,25 ESEER up to 8,88

COOLROW Close control air conditioners for In-Row installation Cooling Capacity: kw

rcgroup.it Flooded evaporator Refrigerant charge HFO1234ze, GWP<1 Low noise Minimum starting current EER up to 5,41 ESEER up to 9,10

unico pf unico pf rcgroupairconditioning

GLIDER EVO FREE GLIDER EVO FREE GLYCOL FREECOOLING. rcgroupairconditioning

NEXT EVO DXR410A NEXT EVO DX NEW SOFTWARE. rcgroupairconditioning

GLIDER EVO GLIDER EVO. rcgroupairconditioning

pyxis u pyxis ua NEW rcgroupairconditioning

PYXIS U PYXIS U. rcgroupairconditioning

GLIDER EVO CLA GLIDER EVO CLA HIGHEFFICIENCY ACLASS. rcgroupairconditioning

pyxis pyxisa NEW rcgroupairconditioning

pyxis hp "u" pyxis hp "u" IDEA NEW rcgroupairconditioning

kw COOLING kw HEATING

pyxis cla pyxis cla A-CLASS NEW rcgroupairconditioning

glider evo cla glider evo cla A-CLASS rcgroupairconditioning

SMART. 4,9 49,5 kw. Air cooled liquid chillers and heat pumps equipped with scroll compressor and axial fans T_SMT_0609_GB

EASY_R R407C. Air cooled liquid chillers and heat pumps equipped with scroll compressor and axial fans. 5,2 41,5 kw T_ESY_R_0508_GB

Packaged air cooled liquid chillers for outdoor installation kw. technicalcatalogue T_EGL_1012_GB

NEXT DL NEXT DL. rcgroupairconditioning

EQEF TECHNICAL CATALOGUE AIR COOLED WATER CHILLERS AXIAL FANS WITH FREE-COOLING SYSTEM

Kelvin air conditioning. KELVIN Clim W280. Cooling Capacity: 280 ~ 1840 kw

UNICO TURBO FL FREE UNICO TURBO FL FREE HIGHEFFICIENCY INVERTER ACLASS FREECOOLING LOWNOISE. rcgroupairconditioning

21,8 222 kw COOLING 25,2 236 kw HEATING

unico turbo FL unico turbo FL LOW NOISE A-CLASS INVERTER rcgroupairconditioning

Kelvin air conditioning. KELVIN Clim W250. Cooling Capacity: 250 ~ 1240 kw

44,9 202,0 kw. technicalcatalogue

kw. technicalcatalogue

KELVIN Clim F497. Kelvin air conditioning

Next P kw COOLING 5 93 kw HEATING. technicalcatalogue. Heat pump air conditioners with upflow air delivery T_NXTP_0411_GB

kw. technicalcatalogue

EQUH PF PACKAGED HEAT PUMP AIR/ WATER LIQUID CHILLER FOR INDOOR INSTALLATION

Next MTR kw. technicalcatalogue. Air conditioners for Metrology Labs with upflow air delivery T_NXTMTR_0511_GB

4,5 22,5 kw. technicalcatalogue. Air-conditioned server-racks for direct installation into the room T_CLSEVO_0113_GB

EQSL TECHNICAL CATALOGUE AIR COOLED WATER CHILLER UNITS AXIAL FANS. Models: 300 V2 F V2 F16. Cooling capacity: 299 to 1310 KW

nemo 5,4 30,5 kw 6,4 37,4 kw R410A PLATE water cooled chillers / heat pumps and motoevaporating units COOLING HEATING

next p dw next p dw rcgroupairconditioning

Zeta Rev LN HP Prochill Bluebox Print Date: 07/17/2017

EQPHU PACKAGED HEAT PUMP AIR/ WATER LIQUID CHILLER FOR OUTDOOR INSTALLATION

turb new unico turbo frigo turbo fl Liquid chiller equipped with magnetic levitation twostage centrifugal compressors RCGROUP SpA C_GNR_0711

SLS 1202 to With or without total heat recovery. u Air Cooled Screw Chillers. 262 to 916 kw. Engineering Data Manual

Water chillers water/water type SIGMA Technical information manual

GLIDER_. air cooled liquid chilled chillers / heat pumps

WSK WSK. Water to water chillers and heat pumps VERSIONS ACCESSORIES

frigo turbo FL Chillers

LDK LDK. Air to water chillers and heat pumps VERSIONS ACCESSORIES

GPE Kc UNITS FOR 4-PIPE SYSTEMS WITH SCROLL COMPRESSORS. COOLING CAPACITY FROM 77 TO 426 kw - 2 COOLING CIRCUITS. GPE 802 Kc + CF + GP + MV + P1

i-next DX kw FULL INVERTER direct expansion air conditioners for IT Cooling. To be matched with remote air-cooled condenser. rcitcooling.

LSK LSK. Air to water chillers and heat pumps VERSIONS ACCESSORIES

Multi-pipe Units with Scroll Compressors. Model CMAA Cooling capacity kw Heating capacity kw

Kälte Klima. Air cooled water chillers air cooled reversible heat pumps from 45 kw to 320 KW. Compressors Scroll SCAEY DE 88 04/11 12/10

next DX.U.S* 052.Z2.H6.DC

AIR-COOLED LIQUID CHILLER FOR OUTSIDE INSTALLATION FROM 4,3 TO 35,1 kw

LZA High efficiency air to water heat pumps with HP compressor

Technical Catalogue. Air-Cooled Liquid Chillers with screw compressors Nominal cooling capacity: kw 50 Hz

AIR COOLED FREE-COOLING CHILLERS WITH SCROLL COMPRESSORS AND AXIAL FANS

CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 47 to 78 kw

WZH Ground source heat pumps

AIR COOLED CHILLERS WITH SCROLL COMPRESSORS AND CENTRIFUGAL FANS

Ultimate energy saving technology

AIR COOLED CHILLERS WITH SCROLL COMPRESSORS AND CENTRIFUGAL FANS

LZT High efficiency air to water heat pumps with E.V.I. compressors

WATER COOLED HEAT PUMP VERTICAL UNIT CONSOLE TYPE OR RECESSED

Superchiller Product Documentation. English. cod rev Issued by TDS

LSA LSA A + Air cooled water chillers with axial fans VERSIONS ACCESSORIES

ULTIMATE ENERGY SAVING TECHNOLOGY

Kälte Klima. Air cooled liquid chiller Free-Cooling from 45 kw to 365 kw. Scroll Compressors SCAEY-FC DE 98

WATER CHILLER UNITS AIR COOLED CONDENSER CENTRIFUGAL FANS HEAT PUMP. EWCBZ COOLING ONLY. EWCZ

next NEXT EVO CW kw UP FLOW DOWN FLOW CHILLED WATER E C CLOSE CONTROL AIR CONDITIONERS FOR CHILLED WATER FEEDING,

CZT CZT. High efficiency air to water heat pumps with E.V.I. compressors E.V.I. HP OTHER VERSIONS ACCESSORIES

EKS/HE. MultiScroll Air-cooled liquid chillers High efficiency. Solution B - Base I - Integrata

PURESTREAM CHILL-CUBE TM BY FRIULAIR

TECHNICAL MANUAL FOR AIR-COOLED CONDENSING UNITS MTE

CMA TECHNICAL MANUAL CONDENSING UNITS FOR OUTDOOR INSTALLATION O L S A F RA N

AIR COOLED CHILLER FOR OUTDOOR INSTALLATION FROM 4,3 TO 35,1 kw

Компрессорно-конденсаторные агрегаты. Chiller. AQH DCI 20 to 30. Air Cooled Water Inverter Heat Pump Engineering Data Manual. 20 to 30 kw.

AIR COOLED HEAT PUMP FOR OUTDOOR INSTALLATION FROM 4,2 TO 35,1 kw

Kälte Klima. Air cooled liquid chiller Free-Cooling from 45 kw to 385 kw. Scroll Compressors SCAEY-FC DE 98

AIR COOLED CHILLERS FOR OUTDOOR INSTALLATION WITH INTEGRATED FREE COOLING MULTISCROLL SERIES

Air cooled chillers. Air cooled chillers with brushless oil-free compressors. RAC. Ka Series - 1 or 2 cooling circuits capacity from 300 to 1400 kw

Flex Series Heat Pumps

Aquaflair. Residential and Industrial Cooling Systems

ERAH MC Ka. Range kw. AIR COOLED CHILLERS WITH SCREW COMPRESSORS AND AXIAL FANS FOR OUTDOOR INSTALLATION (Standard line)

RAH Ka AIR COOLED WATER CHILLERS WITH SCREW COMPRESSORS AND AXIAL FANS. COOLING CAPACITY FROM 387 TO 1207 kw 1 AND 2 COOLING CIRCUITS

Большая библиотека технической документации каталоги, инструкции, сервисные мануалы, схемы.

AQH 40 to 130. u Air-to-Water Reverse Cycle Heat Pumps. 40 to 131 kw. 45 to 141 kw. Engineering Data Manual

Ultimate energy saving technology

RAS Kp AIR COOLED CHILLERS WITH RECIPROCATING COMPRESSORS AND AXIAL FANS REFRIGERANT R290 LIQUID CHILLERS - AIR COOLED AIR

coldpack water cooled chillers / heat pumps and motoevaporating units C_GNR_0508

Air-to-water scroll chillers

LER kw. Indoor motor-driven evaporating units. Motor-driven evaporating units LER PLUS

WHA WHA. Ground source water to water heat pumps A ++ A ++ Versions


Aquaflair TRAC-TRAF-TRAH

Epsilon Echos kw. General information Air-Water unit with scroll compressors driven by DC inverter. Unique selling points

DYNACIAT LGN. Description. Split system Water chillers. High energy efficiency Compact and quiet Scroll compressors Brazed-plate heat exchangers

CMA CONDENSING UNITS FOR OUTDOOR INSTALLATION INSTALLATION AND OPERATION MANUAL

Air cooled industrial chillers

Transcription:

Split-system liquid chillers for indoor installation. Cooling Capacity: 5 26 Built-in pumping group Scroll compressor Plate type heat exchanger EER up to 2,88 rcgroup.it

Chillers : Motoevaporating units for indoor installation, equipped with scroll compressor and plate heat exchangers Cooling Capacity: 5 26 R410A PLATE SPLIT SYSTEM MAIN FEATURES Motoevaporating unit. 13 models available, for a wide selection opportunity. Average step of 2,5. EER up to 2,88. Scroll compressor. R410A Refrigerant charge. Single refrigerant circuit. Plate type heat exchanger. Suitable for indoor installation. MAIN BENEFITS Availability of partial heat recovery system. Availability of kit for the reduction of the noise. Availability of remote condensers with axial fans (TEAM MATE series) and with plug fan (TEAM MATE PF series). Easily of maintenance. INDOOR INSTALLATION The machines are designed for indoor installation. REMOTE CONDENSER The units are designed to be matched with remote condensers with axial fans (TEAM MATE series) or plug-fan (TEAM MATE PF series). COMPLETENESS OF EQUIPMENT AND OPTIONAL The units are standardly equipped with 3-speed water pump. On request is possible to install the system for the domestic hot water production and a chilled water tank. WORKING LIMITS IN COOLING MODE Evaporator chilled water outlet temperature: -12 20 C Ambient temperature: -10 45 C MEHITS S.p.A. - RC Brand G_CHL_RCW9.3 195

MAIN COMPONENTS FRAMEWORK Base, self supporting frame and panelling in steel plate with protective surfaces treatment in compliance with UNI ISO 9227/ASTMB117 and ISO 7253, and painted with epoxy powders. Colour: RAL 9002 Insulation of the internal framework. Chillers TO BE MATCHED WITH REMOTE CONDENSER The units are designed to be matched with remote condensers with axial fans (TEAM MATE series) or plug-fan (TEAM MATE PF series). COMPRESSOR Orbiting spiral (SCROLL) hermetic compressors with spiral profile optimized for R410A refrigerant. ON / OFF capacity control (0 / 100%). Crankcase heater. Electric motor thermal protection via internal winding temperature sensors. Rubber supports. Electric motor: - Version M: single-phase electric motor with direct on line starting. - Version T: 2-pole 3-phase electric motor with direct on line starting. Phase sequence electronic relay. EVAPORATOR Copper brazed plate type with cover plates, plates and connections in AISI 316 stainless steel. Anticondensate insulation made of polyurethane. Temperature sensors on water inlet and outlet. Differential water pressure switch for water flow control. 3-speed circulation pump. REFRIGERANT CIRCUIT Thermostatic expansion valve. Service valves on liquid line and gas discharge. Pressure transducers with indication, control and protection functions, on low and high refrigerant pressure. 0 10V proportional signal to manage the condensing control system of the remote air cooled condenser. High pressure safety switch with manual reset. Refrigerant circuit with copper tubing with anticondensate insulation of the suction line. Plastic capillary hoses for pressure sensors connection. R410A refrigerant charge. ELECTRICAL PANEL In accordance with EN60204-1 norms, suitable for indoor installation complete with: Main switch. Magnetothermic switch or fuses for compressor. Contactor for compressor. Transformer for auxiliary circuit and microprocessor supply. nel with machine controls. Power supply: - M: 230/3/50 - T: 400/3/50+N CONTROL SYSTEM Microprocessor control. The system includes: - Display for the visualization of the alarm codes, set values and temperature values. - Dynamic set point. - Compressor running hour meter. - Contact for general alarm remotization. - Low Temperature set for operation with ambient air temperature up to -10 C. TEAM MATE TEAM MATE PF 196 G_CHL_RCW9.3 MEHITS S.p.A. - RC Brand

Chillers OPTIONAL ACCESSORIES MODEL TEAM MATE remote condensers TEAM MATE PF remote condensers 450 - rtial heat recovery 610 - Noise deading cup on compressor 764 - Water tank 117 - Low water temperature set 920 - Remote control kit 923 - RC-Com MBUS/JBUS Serial board 962 - Kit modem GSM 957 - Plantwatch without modem 930 - Remote graphic terminal kit M 06 P1 M 08 P1 M 10 P1 M 13 P1 T 06 P1 T 08 P1 T 10 P1 T 13 P1 T 15 P1 T 17 P1 T 20 P1 T 25 P1 T 30 P1 J3 J3 J3 J3 J3 J3 J3 J3 J3 J3 J3 J3 J3 available accessory; - not available accessory MEHITS S.p.A. - RC Brand G_CHL_RCW9.3 197

Chillers TECHNICAL DATA STANDARD TEAM MATE PF ELN TEAM MATE PF LNO TEAM MATE PF STD TEAM MATE ELN TEAM MATE LNO OPT TEAM MATE 198 SIZE (*) Evaporator water flow rate m³/h k Evaporator pressure drop Compressors Quantity n. Capacity steps n. Pumping group 3-speed water pump Refrigerant Total refrigerant charge (optional excluded) kg Gas circuits n. Power supply Max unit operating current (FLA) (*) A Unit starting current (LRA) A / Sound power level [Lw] (2) db(a) Average sound pressure level [Lpm] (3) db(a) Net weight kg Hydraulic connections Evaporator IN/OUT - ISO228/1-G M Ø Refrigerant connection Liquid return n x Ø Gas delivery n x Ø Series TEAM MATE STD Max operating current A rtial heat recovery - Heating Capacity (4) Water tank - volume l + TEAM MATE LNO / Series TEAM MATE LNO + TEAM MATE ELN / Series TEAM MATE ELN + TEAM MATE PF STD / Series TEAM MATE PF STD + TEAM MATE PF LNO / Series TEAM MATE PF LNO + TEAM MATE PF ELN / Series TEAM MATE PF ELN M 06 P1 M 08 P1 M 10 P1 M 13 P1 T 06 P1 T 08 P1 T 10 P1 T 13 P1 J3 J3 J3 J3 J3 J3 J3 J3 5,4 7,1 9,2 12,1 5,4 6,9 9,2 12,0 2,0 2,6 3,4 4,2 1,9 2,5 3,3 4,3 0,9 1,2 1,6 2,1 0,9 1,2 1,6 2,1 31 21 28 23 31 20 28 23 scroll scroll scroll scroll scroll scroll scroll scroll 1 1 1 1 1 1 0,4 0,4 0,4 0,4 0,4 0,4 0,4 0,4 R410A R410A R410A R410A R410A R410A R410A R410A 4,7 4,8 5,1 5,4 4,7 4,8 5,1 5,4 1 1 1 230/1/50 230/1/50 230/1/50 230/1/50 400/3/50+N 400/3/50+N 400/3/50+N 400/3/50+N 15,6 20,1 24,2 34,7 7,1 8,9 10,5 12,9 62,0 69,0 100,0 117,5 30,0 40,0 45,0 53,5 2,76 2,69 2,70 2,88 2,77 2,73 2,79 2,78 56,2 56,2 58,2 58,2 56,2 56,2 58,2 58,2 42,0 42,0 44,0 44,0 42,0 42,0 44,0 44,0 51,0 51,0 54,5 66,0 51,0 51,0 54,5 66,0 1 1/2" 1 1/2" 1 1/2" 1 1/2" 1 1/2" 1 1/2" 1 1/2" 1 1/2" 10 10 10 12 10 10 10 12 10 10 10 12 10 10 10 12 1 1 1 M 11 M 11 M 14 M 17 M 11 M 11 M 14 M 17 0,3 0,3 0,3 0,3 0,3 0,3 0,3 0,3 1,2 1,2 1,2 1,2 1,2 1,2 1,2 1,2 230/1/50 230/1/50 230/1/50 230/1/50 230/1/50 230/1/50 230/1/50 230/1/50 2,0 2,6 3,4 4,4 2,0 2,5 3,4 4,4 40 40 40 40 40 40 40 40 5,4 7,0 9,0 12,1 5,3 6,8 9,0 12,1 1,9 2,7 3,5 4,3 1,9 2,5 3,4 4,4 2,75 2,61 2,59 2,83 2,74 2,67 2,68 2,76 1 1 1 M 11 M 11 M 14 M 20 M 11 M 11 M 14 M 20 0,2 0,2 0,2 0,3 0,2 0,2 0,2 0,3 230/1/50 230/1/50 230/1/50 230/1/50 230/1/50 230/1/50 230/1/50 230/1/50 5,3 6,8 8,7 11,7 5,3 6,6 8,7 11,7 2,0 2,8 3,6 4,4 2,0 2,6 3,5 4,5 2,66 2,48 2,43 2,66 2,67 2,55 2,52 2,59 1 1 1 M 11 M 11 M 14 M 20 M 11 M 11 M 14 M 20 0,2 0,2 0,2 0,3 0,2 0,2 0,2 0,3 230/1/50 230/1/50 230/1/50 230/1/50 230/1/50 230/1/50 230/1/50 230/1/50 5,4 7,1 8,8 11,7 5,4 6,9 8,9 10,9 2,1 2,8 3,7 4,6 2,1 2,7 3,6 5,1 2,59 2,56 2,37 2,56 2,60 2,60 2,45 2,13 1 1 1 T 11 T 11 T 11 T 14 T 11 T 11 T 11 T 11 50 50 50 50 50 50 50 50 0,4 0,4 0,4 0,4 0,4 0,4 0,4 0,4 380-480/3/50-60 380-480/3/50-60 380-480/3/50-60 380-480/3/50-60 380-480/3/50-60 380-480/3/50-60 380-480/3/50-60 380-480/3/50-60 5,5 7,3 9,1 11,8 5,5 7,1 9,1 11,8 1,9 2,6 3,5 4,4 1,9 2,5 3,4 4,5 2,84 2,82 2,61 2,68 2,84 2,85 2,70 2,61 1 1 1 T 14 T 14 T 14 T 17 T 14 T 14 T 14 T 17 36 36 36 36 36 36 36 36 0,3 0,3 0,3 0,3 0,3 0,3 0,3 0,3 380-480/3/50-60 380-480/3/50-60 380-480/3/50-60 380-480/3/50-60 380-480/3/50-60 380-480/3/50-60 380-480/3/50-60 380-480/3/50-60 5,4 7,1 8,9 11,4 5,4 6,9 8,9 11,4 1,9 2,5 3,5 4,5 1,9 2,4 3,4 4,7 2,90 2,79 2,52 2,53 2,91 2,84 2,61 2,45 1 1 1 T 14 T 14 T 14 T 17 T 14 T 14 T 14 T 17 25 25 25 25 25 25 25 25 0,2 0,2 0,2 0,2 0,2 0,2 0,2 0,2 380-480/3/50-60 380-480/3/50-60 380-480/3/50-60 380-480/3/50-60 380-480/3/50-60 380-480/3/50-60 380-480/3/50-60 380-480/3/50-60 1. Referred to chilled water temperature 12/7 C 0% glycol solution; air temperature to the condenser 35 C. Fouling factor of the exchangers 0,043 m² K/. 2. Sound power level [Lw] according to ISO EN 9614-2 3. Average sound pressure level [LPm] 1m far according to ISO EN 3744. 4. Referred to chilled water temperature 12/7 C 0% glycol solution; air temperature to the condenser 35 C; water temperature heat recovery 40/45 C 0% glycol solution. Fouling factor of the exchangers 0,043 m² K/. (*) The value includes the remote condenser (**) The remote condenser has separated power supply G_CHL_RCW9.3 MEHITS S.p.A. - RC Brand

Chillers TECHNICAL DATA STANDARD TEAM MATE PF ELN TEAM MATE PF LNO TEAM MATE PF STD TEAM MATE ELN TEAM MATE LNO OPT TEAM MATE SIZE (*) Evaporator water flow rate m³/h k Evaporator pressure drop Compressors Quantity n. Capacity steps n. Pumping group 3-speed water pump Refrigerant Total refrigerant charge (optional excluded) kg Gas circuits n. Power supply Max unit operating current (FLA) (*) A Unit starting current (LRA) A / Sound power level [Lw] (2) db(a) Average sound pressure level [Lpm] (3) db(a) Net weight kg Hydraulic connections Evaporator IN/OUT - ISO228/1-G M Ø Refrigerant connection Liquid return n x Ø Gas delivery n x Ø Series TEAM MATE STD Max operating current A rtial heat recovery - Heating Capacity (4) Water tank - volume l + TEAM MATE LNO / Series TEAM MATE LNO + TEAM MATE ELN / Series TEAM MATE ELN + TEAM MATE PF STD / Series TEAM MATE PF STD + TEAM MATE PF LNO / Series TEAM MATE PF LNO + TEAM MATE PF ELN / Series TEAM MATE PF ELN T 15 P1 T 17 P1 T 20 P1 T 25 P1 T 30 P1 J3 J3 J3 J3 J3 13,6 16,2 17,7 21,5 26,0 4,9 5,6 6,6 7,7 9,1 2,3 2,8 3,0 3,7 4,5 30 25 30 32 29 scroll scroll scroll scroll scroll 0,4 0,4 0,4 0,4 0,4 R410A R410A R410A R410A R410A 5,4 5,8 5,8 6,5 7,1 400/3/50+N 400/3/50+N 400/3/50+N 400/3/50+N 400/3/50+N 14,5 17,9 17,9 24,2 25,2 66,0 77,0 103,0 113,0 120,0 2,80 2,88 2,68 2,78 2,86 61,2 65,2 62,2 64,2 64,2 47,0 51,0 48,0 50,0 50,0 72,0 102,0 102,0 111,0 120,0 1 1/2" 1 1/2" 1 1/2" 1 1/2" 1 1/2" 12 12 12 16 16 12 12 12 16 16 M 20 M 25 M 25 M 30 M 35 0,4 0,5 0,5 0,5 0,5 1,8 2,9 2,9 2,9 2,9 230/1/50 230/1/50 230/1/50 230/1/50 230/1/50 5,0 5,9 6,5 7,9 9,6 40 40 40 40 40 13,8 16,6 18,2 22,4 26,6 4,8 5,3 6,3 7,4 9,0 2,86 3,11 2,91 3,01 2,97 M 25 M 30 M 30 M 45 M 45 0,5 0,5 0,5 0,7 0,7 230/1/50 230/1/50 230/1/50 230/1/50 230/1/50 13,4 16,3 17,7 21,9 25,8 4,9 5,4 6,4 7,6 9,2 2,74 3,00 2,77 2,89 2,80 M 25 M 30 M 30 M 45 M 45 0,4 0,4 0,4 0,6 0,6 230/1/50 230/1/50 230/1/50 230/1/50 230/1/50 13,3 15,8 17,7 21,8 25,7 5,0 5,8 6,7 8,4 10,0 2,64 2,73 2,65 2,61 2,57 T 17 T 21 T 24 T 33 T 33 50 50 50 50 50 0,5 0,5 0,6 1,3 1,3 380-480/3/50-60 380-480/3/50-60 380-480/3/50-60 380-480/3/50-60 380-480/3/50-60 13,4 15,9 18,4 21,8 25,7 4,9 5,7 6,5 7,8 9,4 2,74 2,81 2,82 2,79 2,72 T 21 T 24 T 33 T 38 T 38 36 36 36 36 36 0,3 0,4 0,8 0,7 0,7 380-480/3/50-60 380-480/3/50-60 380-480/3/50-60 380-480/3/50-60 380-480/3/50-60 12,9 15,4 17,9 21,2 24,8 5,0 5,8 6,5 7,9 9,6 2,59 2,67 2,77 2,70 2,57 T 21 T 24 T 33 T 38 T 38 25 25 25 25 25 0,2 0,3 0,5 0,5 0,5 380-480/3/50-60 380-480/3/50-60 380-480/3/50-60 380-480/3/50-60 380-480/3/50-60 1. Referred to chilled water temperature 12/7 C 0% glycol solution; air temperature to the condenser 35 C. Fouling factor of the exchangers 0,043 m² K/. 2. Sound power level [Lw] according to ISO EN 9614-2 3. Average sound pressure level [LPm] 1m far according to ISO EN 3744. 4. Referred to chilled water temperature 12/7 C 0% glycol solution; air temperature to the condenser 35 C; water temperature heat recovery 40/45 C 0% glycol solution. Fouling factor of the exchangers 0,043 m² K/. (*) The value includes the remote condenser (**) The remote condenser has separated power supply MEHITS S.p.A. - RC Brand G_CHL_RCW9.3 199

Chillers DIMENSIONS (mm) 900 555 650 200 G_CHL_RCW9.3 MEHITS S.p.A. - RC Brand

RC Brand: Via Roma 5-27010 Valle Salimbene (PV) - Italy Tel +39 (0) 382 433 811 - Fax +39 (0) 382 587 148 www.rcgroup.it www.melcohit.com Eco-Changes is the Mitsubishi Electric Group's environmental statement, and expresses the Group's stance on environmental management. Through a wide range of businesses, we are helping contribute to the realization of a sustainable society.