Alpha Aire. Dedicated Outdoor Air System, VAV, Air-Source Heat Pump with Energy Recovery

Similar documents
Alpha Aire. Dedicated Outdoor Air System, VAV, Air-Source Heat Pump with Energy Recovery. Engineering Guide Effective February 2018

VariCool VAV. (Variable Air Volume) 9 to 70 tons Variable Air Volume Water-Cooled and Chilled Water. Unique Solutions for All-Indoor HVAC Projects

OmegaAir. 100% Dedicated Outside Air System (DOAS)

C-Series. Unique Solutions for All-Indoor HVAC Projects

CoolSpot Engineering Guide

MiniCool Ductless Split A/C Systems 1 9 Tons Single or Multi-Compressor Circuits Air-Cooled, Water-Cooled, and Chilled Water

VariCool VAV Engineering Guide

VertiCool CLASSIC. Engineering Guide. Effective March Air-Cooled, Water-Cooled, Chilled Water and Water Source Heat Pump

VertiCool Space Saver 2 to 15 Tons Water-Cooled and Chilled Water Air-Cooled w/remote Condenser

CoolSpot. Unique Solutions for All-Indoor HVAC Projects

VariCool EZ-Fit 12 to 70 Tons Variable Air Volume Water-Cooled Water Source Heat Pump Chilled Water

IAQ VENTILATORS. FRESH AIR REQUIREMENTS. Applications ASHRAE 62.1, 90.1 & School / university / day care.

C13-Series. Unique Solutions for All-Indoor HVAC Projects

DOAS UNITS. ReznorHVAC.com MAKEUP AND VENTILATION AIR 100% OUTSIDE AIR

REPORT OF THE UMC VENTILATION TASK GROUP

CHAPTER 4 VENTILATION AIR SUPPLY

VariCool EZ-Fit. Unique Solutions for All-Indoor HVAC Projects

Modular Indoor Systems For Effective Environmental Control

UNIVERSITY OF MISSOURI Heating Ventilating and Air-Conditioning (HVAC) 2016 Q1

Trane Engineers Newsletter Live

The ultimate fresh air solution.

Bring the fresh in. D E D I C A T E D O U T S I D E A I R S Y S T E M

RT-OA TM Rooftop Outdoor-Air (DOAS)

Energy Recovery with Cooling and Heating Model ERCH

Heat Pumps SB SERIES. Vertical Self-Contained Unit Water-Source Heat Pumps (3-18 tons) Features:

DX Units. Ranging from 15 to 750 tons and 1,000 to 300,000+ CFM

HAP e-help. Modeling Induction Beams in HAP v4.8 QB TIP 001

ENGINEERING. Edition No. 13 October 2002

Introduction to HVAC. American Standard Inc Air Conditioning Clinic TRG-TRC018-EN

BOOK 1 OVERVIEW RD2XIN INSTALLATION AND OPERATION MANUAL. Table of Contents ABOUT BOOK 1:

Maverick II Commercial Rooftop Systems 15 to 75 tons

System Components with ` Emphasis on Packaged Rooftop Application and Installation. Jerry Cohen President Jacco & Assoc.

BOOK 1 OVERVIEW RD2XRT INSTALLATION AND OPERATION MANUAL. Table of Contents ABOUT BOOK 1:

Dehumidifying with Dedicated Outdoor Air

PoolPak MPK Series. PoolPak.com. Environmental Control Systems REDUCED FOOTPRINT & WEIGHT COMPARED TO EARLIER GENERATIONS

PINNACLE SERIES DEDICATED OUTDOOR AIR SYSTEM ENERGY EFFICIENT DEHUMIDIFICATION

AIR-CONDITIONING SYSTEMS AND APPLICATIONS. Abdullah Nuhait Ph D. King Saud University

THE ULTIMATE ROOFTOP SOLUTION

Heat Pumps SA SERIES. Vertical Self-Contained Unit Water-Source Heat Pumps (23-70 tons) Features:

HVAC 101. The Basics of Heating, Ventilation and Air Conditioning

DEHUMIDIFICATION: Ice Arena Application & Product Guide. Design, construct and operate to control indoor humidity in ice rinks

Water-Source Heat Pumps

Heat Pumps SB SERIES. Vertical Self-Contained Unit Water-Source Heat Pumps (3-18 tons) Features:

Rooftop Ventilator. Models RV and RVE. with Packaged Cooling & Heating

Single Zone System. One duct system Used mostly in small buildings Forced air system All spaces controlled by a single thermostat Single air return

DADANCO Technical Paper

RoofPak Applied Rooftop Systems

HVAC 101. H V A C S y s t e m s

PACKAGED ROOFTOP UNITS, AIR-SOURCE HEAT PUMPS, WATER-SOURCE / GEOTHERMAL HEAT PUMPS, & OUTDOOR AIR HANDLING UNTS. RQ Series.

VERTICOOL TECHNICAL DATA MANUAL. Vertical Air/Water Cooled 3-25 Tons

MECHANICAL SYSTEMS CHAPTER 28

Energy-Efficient Makeup Air Units BY HUGH CROWTHER, P.ENG., MEMBER ASHRAE

HVAC DISTRIBUTION and DELIVERY SYSTEMS

Design Considerations For Dedicated OA Systems BY HUGH CROWTHER, P.ENG, MEMBER ASHRAE; YI TENG MA, ASSOCIATE MEMBER ASHRAE

RN/RQ. Series PACKAGED ROOFTOP UNITS, AIR-SOURCE HEAT PUMPS, WATER-SOURCE/ GEOTHERMAL HEAT PUMPS, & OUTDOOR AIR HANDLING UNITS.

T-CLASS Commercial Split Systems Up to 20-Ton TSA/TPA Models

CB/CF. Series CONDENSERS AND CONDENSING UNITS. Features:

ENERGY EFFICIENCY WITH SUPERIOR INDOOR AIR QUALITY

1080 Marina Village Parkway, Suite 501 Alameda, CA (510) Fax (510) HVAC DESIGN INTENT

62DA,DB,DC,DD,DE,DF07-38

Inspection Phase Three. Mechanical, Electrical & Plumbing Section 503

Performance and rugged durability. Commercial Split Systems Up to 20-Ton TSA/TPA Models

COMMERCIAL HVAC PACKAGED EQUIPMENT. Split Systems

Purify your world Bring a breath of fresh air to your business with vänee light commercial ERV and HRV solutions the energy-efficient choice for

Energy Recovery with Cooling and Heating

ALL PRODUCTS BROCHURE

In Search of the Magic Box: A Review of Crossover Conditioning/Ventilation/ Dehumidification Devices on the US Market

2 Existing Mechanical System

EP SERIES PACKAGED ENERGY RECOVERY SYSTEM ENERGY EFFICIENT AIR COMFORT

Mechanical Technical Report 1. ASHRAE Standard 62.1 Ventilation Compliance Evaluation

Inverter Ducted Split Air Source Heat Pump. Simply Smart. System with Inverter Drive Technology. boschheatingandcooling.com

Series. Packaged Rooftop Units, heat pumps and Outdoor air handling Units. Features:

CONDENSERS AND CONDENSING UNITS

Topic 2. ME 414/514 HVAC Systems Overview Topic 2. Equipment. Outline

Series PACKAGED ROOFTOP UNITS, HEAT PUMPS AND OUTDOOR AIR HANDLING UNITS. Features:

Mechanical System Redesign. Dedicated Outdoor Air System. Design Criteria

Best Practices for Applied Rooftop ` Systems, Applications and. Jerry Cohen President Jacco & Assoc. Installation

LIGHT COMMERCIAL Heat and Energy Recovery Ventilators

Designing Energy Efficient Outdoor Air Systems

Heat Recovery Ventilator Model PVe Light Industrial Commercial Institutional

SKYPAK II, 3 Ton Series, gives you a

D-PAC. Digital Precise Air Control System. Functionality Factory Testing Ease of Installation Ease of Maintenance Energy Efficiency

50 Series AQUAZONE Water Source Heat Pumps

Bill McCullough. Director ERV Products. Dallas, TX

Greensource Residential Water Source Heat Pumps. Simply Smart. i Series: SV Model. boschheatingandcooling.com

The best way to enhance indoor air quality

Appendix 13. Categories of Cooling and Heating systems

Ball State Architecture ENVIRONMENTAL SYSTEMS 2 Grondzik 1. Contextual Reminder

Munters Heat Exchangers

IAQ Building Education and Assessment Model (I-BEAM)

Building Systems: HVAC

ASHRAE/IESNA Standard

Daikin Blueprint: Delivering Hot Water with a Chiller

HONORABLE MENTION: COMMERCIAL BUILDINGS, EXISTING

Standards and Guidelines. Presented by: Aric Murray December 12, 2014

Vision and Skyline Semi-custom Air Handlers

Heat Pumps SA SERIES. Vertical Self-Contained Unit Water-Source Heat Pumps (23-70 tons) Features:

Retrocommissioning Findings Summary: Building X #1 Priority: Major Comfort/Control Problems

WORKSHOP VENTILATION- PSYCHROMETRICS-AHU

Best Practices for Applied Rooftop ` Systems - Application and. Jerry Cohen President Jacco & Assoc. Installation

Transcription:

Dedicated Outdoor Air System, VAV, Air-Source Heat Pump with Energy Recovery All Indoor Installation One Size Fits All 100 to 500 CFM Air-Source Heat Pump Variable Air Volume Air-Cooled Self Contained Direct Expansion w/ Energy Recovery Unique Solutions for All-Indoor HVAC Projects

Let the Fresh Air In! The Newest All-Indoor Solution by United CoolAir Indoor air quality can be adversely affected by many factors. Indoor pollutants can lead to a variety of health risks, especially for those already susceptible to such factors. Studies show that introducing conditioned outside air can lead to better health and performance of occupants in a variety of settings. ASHRAE 62.1-2016 requires minimum OSA per code. is the first choice in introducing fresh air into buildings for a simple and quick installation for challenging or existing retrofit applications. 2

Features & Options United CoolAir uses high-density 2" thermal/acoustic insulation Solid Double Wall along with low airflow to greatly reduce noise for near occupant operation. Critical components are isolated out of the air stream for longer life, and thermal breaks prevent unwanted condensate formation. Single point electrical power and 8" flex duct make for a low cost installation. The sheet metal is G90 galvanized steel with optional wet paint finish for durability and long life. FEATURES Single cabinet design 2" Solid double wall Self contained DX system Dual Energy recovery Devices Auxiliary Reheat Coil Variable Air Volume Capable (Through BMS) Up to 1" of ESP Heat pump Field convertible return/supply air panel Stainless steel drain pans 2" Merv 8 pleated throwaway filters 208/230-1 power ECM fans 100 500 CFM OPTIONS Painted cabinet (Wet paint) Non-fused disconnect Coated Coils Buck Boost Transformer External condensate pump 4" MERV 11 or 13 filters Smoke detector Occupancy switch VOC switch CO 2 switch Floor Stand VENTILATION RATES PER ASHRAE 62.1-2016 * Based on TABLE 6.2.2.1 Minimum Ventilation Rates in Breathing Zone Occupancy Category CFM/Person Occupancy Category CFM/Person Art Classroom 10 Lecture Room 7.5 Bank or Bank Lobbies 7.5 Legislative Chambers 5 Bar/Cocktail Lounge 7.5 Libraries 5 Beauty and Nail Salon 20 Lobby/Pre-function 7.5 Bowling Alley 10 Museum 7.5 Break Room 5 Music/Theater/Dance 10 Cafeteria/Fast Food Dining Room 7.5 Office Space 5 Conference/Meeting Room 5 Pet Shop 7.5 Correctional Facilities 5 Pharmacy (prep area) 5 Courtroom 5 Places of Worship 5 Daycare/Classrooms 10 Reception Area 5 Gambling Casino 7.5 Restaurant Dining Room 7.5 Health Club/Aerobics 20 Retail Store 7.5 Hotel Room 5 Science Lab 10 Laundry Room 5 Super Market 7.5 * See ASHRAE standard 62.1-2016 for complete standards and definition. 3

The Final Word in Low CFM Outside Air Systems Today s commercial buildings are designed and built with energy efficiency in mind. New construction techniques and materials used for the shell of the building minimize heat gains and losses and prevent the unwanted infiltration of moisture-laden outside air from entering the space, thereby decreasing the cost of space conditioning. To maintain the latest ASHRAE Standard 62.1-2016 ventilation requirements, owners/operators of commercial buildings generally have to depend on up-sized packaged rooftop HVAC systems not only to condition the recirculating air but to also bring in fresh OA to meet IAQ requirements. This results in larger equipment investments and higher operating costs. Side View The Solution is A simpler, more effective solution is a 100% dedicated outside air system (DOAS) from United CoolAir Corporation working in conjunction with a space sensible heating/cooling system. United CoolAir Corporation s 100% outside air unit is a standalone system designed to meet the OA requirements for today and years to come. Traditional HVAC systems are designed primarily to handle design sensible loads and are not adequately designed for the high latent loads produced by outside air. The is designed to exclusively handle the large latent ventilation load and deliver neutral air of 70ºF to 72ºF @ 50% RH. s supply air dew point design temperature is lower than standard air conditioners to remove the maximum amount of moisture before delivery to the space. Divide and Conquer By separating the sensible load from the latent load, the removes the moisture from its primary source fresh outdoor ventilation air at the lowest cost. can further assist the main space conditioning unit by handling some of the smaller internally generated amounts of latent and sensible loads that naturally build from occupants and other sources. The result is better IAQ at a lower cost! 4

Basic Model Designation AA H 100 G1 AS T A X Series Configuration Horizontal - H Series 100 Voltage G1-208/230-1-60 2 TOP Special Configuration Refrigerant Type A - R-410A Cabinet Series T - Traditional Cabinet Quantity of Refrigerant HANGING Circuits PROVISIONS 76 AS - Single Circuit (4) Ø.625 HOLES United CoolAir designed the with installation flexibility in mind. The compact horizontal configuration can be easily installed. 26 3 4 2 TOP 76 HANGING PROVISIONS (4) Ø.625 HOLES POWER & CONTROL WIRING 8" SUPPLY AIR DUCT FILTER ACCESS 28 26 3 4 POWER & CONTROL WIRING The All-Indoor 8" SUPPLY AIR DUCT Concept A United CoolAir FILTER 28 ACCESS Exclusive (2) CONDENSATE The like all UCA 8" RETURN air AIR conditioning DUCT DRAIN 3/4" FPT equipment RIGHT is designed for indoor installation! Air handlers and condensers require no exterior mounting space, which is critical in multi-floor, urban applications. Indoor unit mounting preserves the architectural integrity of the building by keeping the roof and perimeter free of obstructions. In addition to eliminating the roof loads, the installation and maintenance costs is lower, the equipment is protected from the elements and security is enhanced because of limited outdoor access. (2) CONDENSATE DRAIN 3/4" FPT RIGHT Outside Air Exhaust Air 8" RETURN AIR DUCT Exhaust/Return Air Supply Air 5

Unique Solutions for All-Indoor HVAC Projects VertiCool Classic Vertical, 3-30 Ton VertiCool Aurora Vertical, 3-35 Tons Portable Cooling and Heating Units 3-30 Tons Authorized Distributor: C13-Series Horizontal 2-10 Tons VariCool VAV, 9-70 Tons VariCool EZ-Fit VAV, 12-90 Tons C-Series Horizontal 1-15 Tons Special Configuration Engineered to Order 100 500 CFM OmegaAir Horizontal and Vertical 100% Outside Air 150 3000 CFM LIMITED WARRANTY United CoolAir Units are backed by a 1 year limited warranty on parts and a 5 year limited warranty on the compressor (labor not included). Maintenance items such as filters and belts are excluded under this limited warranty. FACTORY TESTED All units are functionally run tested before shipment to ensure a trouble-free start-up and unit commissioning. Industry proven components are used throughout to enhance system reliability and peace of mind. Scan to learn more about all of our products! 491 East Princess Street, York, PA 17403 Phone: 717-843-4311 Fax: 717-854-4462 email: uca@unitedcoolair.com web: www.unitedcoolair.com Copyright by United CoolAir Corporation 2017. All rights reserved. Manufacturer reserves the right to make changes without notice. 70.7-SB (0917)