pre-wired E3FA-TP11-F2 2M E3FB-TP11-F2 2M

Similar documents
E3FA PHOTOELECTRIC SENSORS

E3FA/E3RA/E3FB/E3RB. Application specific models. Limited-reflective types suitable for detecting transparant film to shiny, mirror film.

E3FA PHOTOELECTRIC SENSORS

E3FA PHOTOELECTRIC SENSORS

E3M-V. Mark Sensor. Applications

Color Mark Sensor. Sensing gdsa distance Spot diameter e. Possible to switch between vertical or horizontal connection using the M12 rotary connector.

Transparent Object (PET Bottle) Detection Compact Photoelectric Sensor

10 to 30 VDC Diffuse 40 mm ±10 mm NPN and PNP, switch-selectable

E3FA PHOTOELECTRIC SENSORS

Compact, Photoelectric Sensor with Built-in Amplifier and Teaching Function. Mark Sensor with Stainless Steel Housing

onlinecomponents.com

Sensing for standard and special applications

Transparent Object (PET Bottle) Detection Compact Photoelectric Sensor

Transparent Object (PET Bottle) Detection Compact Photoelectric Sensor

Ultrasonic Proximity Sensor

Ultrasonic Proximity Sensor

Control Panel Basics Volume 1

Small diffuse reflective and convergent reflective type BYD50-DDT BYD50-DDT-U 1 BYD100-DDT BYD3M-TDT BYD3M-TDT-P

ES2-HB-N. Ordering Information. Specifications. Temperature/Humidity Sensor ES2-THB-N. Humidity Sensor

Ultrasonic Reflective Sensor

Reliable Detection of Transparent Objects

F3UV. Monitoring output state of UV (ultraviolet light)/illumination light source. Ultraviolet power monitor/illumination monitor.

High Reliability Of Fiber Optic Amplifier For Convenient Mounting

Ultrasonic Reflective Sensor

Plug-in Base, Long Range Sensor E3B2

RFID Non-contact switches are designed to monitor hinged, sliding or removable guard doors. RFID technology provides increased tamper resistance.

panasonic.net/id/pidsx/global Gentle start-up switches in accordance with ergonomics Reduces load on hands and fingers

Digital Panel Meter K3TL. Ordering Information. Low-cost, High-quality Digital Thermometer with Built-in Microcomputer. Accessories (Order Separately)

EE-SX91. Meeting Customer Needs with Compact Sensors that Mount with M3 Screws

culus and CE Marked for all applicable directives Operating Environment Operating Temperature [C (F)]

Class 1 laser beam sensor safe for your eyes

enproteko.com Specifications Ratings Item voltage to 24 VAC 5/6 Hz 24 VAC 5/6 Hz or 24 VDC Allowable voltage Characteristics 85% to 11% of power suppl

BSF4-AH80. Flameproof Type Light Curtain Type 4. Globally-compliant flameproof structure. Ample protective height 1,595 mm 62.

SENSORS. S8 Series HIGHLIGHTS APPLICATIONS. Phone: Fax: Web: -

Class 1 laser beam sensor safe for your eyes

Class 1 laser beam sensor safe for your eyes

E2K-L. Liquid Level Sensor That Is Unaffected by the Color of the Pipe or Liquid. Liquid Level Sensor. Ordering Information

Selection guide...p.457~ SF-C13...P.663~ Glossary of terms... P.1549~ General precautions... P panasonic.net/id/pidsx/global

Retro-reflective Sensing range: 0mm to 2000mm

The display section precisely shows the current status to onsite operators. Displayable Status Easily Recognize the PV Easily See

Item Symbol Rating Unit Power supply V CC 12.0 VDC Output voltage V OUT 3.0 VDC

Communications None RS-232C RS-422* RS-485* BCD Transmission output*/** (4 to 20 ma) E5AX- E5AX- L(M)A02 L(M)A03

Flameproof Type Light Curtain Type 4

Selection Guide. Logic: From basic to programmable network controllers» Safety Components. Output: Safety relays, servo systems, and inverters

Background suppression photo sensors

Series Description. Features. Available Models. Specifications. Specifications for All Models. Specifications for Standard Models

Emitter. Emitting circuit. Control circuit. Check. Monitoring section (CPU) Emitting element failure. Emitting circuit failure

Adjustable Range Reflective Photoelectric Sensor. panasonic.net/id/pidsx/global

TEMPERATURE CONTROLLER

Adjustable Range Reflective Photoelectric Sensor. General terms and conditions... F-17 Glossary of terms / General precautions...p.1359~ / P.

Communications* None RS-232C RS-422 RS-485 BCD Transmission output** (4 to 20 ma)

Reliable Detection of Transparent Objects

XUM0APSAM8 photo-electric sensor - XUM - multi - Sn 0..10m VDC - M8

Laser Collimated Beam Sensor

5 m pre-wired 2NC/1NO F3S-TGR-NLMX m pre-wired 2NC/1NO F3S-TGR-NLMX m pre-wired 2NC/1NO F3S-TGR-NBMX-21-05

HANDBUCH / MANUAL / MANUEL / MANUALE TopScan-S

Exercise 1. Introduction to Sensors EXERCISE OBJECTIVE

XUX0AKSAM12 photo-electric sensor - XUX - multi - Sn 0..40m VDC - M12

Model Number Structure

Scanning Laser Range Finder Smart-URG mini UST-10LN Specification

UNIVERSAL COMPACT SENSORS

Mark and Colour Sensors

Contents. Photoelectric Sensors / Standard Sensors...4. Safety Sensors Photoelectric Sensors / Miniature Sensors... 12

Appearance and sensing characteristic Specification (temperature range) Model 10 to 70 C ES1B. 2 mm 20 mm 40 mm 60 mm. 40 dia. 60 dia.

BOS 23K. Photoelectric Sensors BOS 23K

Tubular Optical Sensors. BOS S18 Economical Series Applications. Description. Features

Products designed for extreme washdown environments IP69K Products

Throughbeam photoelectric sensor for the detection of aqueous liquids. Dimensioned drawing

Selectable 2sec., 7sec., 15sec. (selectable by holding time setting switch)

FACTORY AUTOMATION SENSE WITH SIMPLICITY AND CONFIDENCE PHOTOELECTRIC FIBER AMPLIFIER SU18 AND SU19 SERIES

General terms and conditions... F-7 General precautions... P panasonic.net/id/pidsx/global. Use as a warning. Sensor. Emergency stop.

Laser retro-reflective photoelectric sensor with polarization filter. Dimensioned drawing

Table of Contents. Page Quick Set-up Instructions 1. Theory of Operation 2. Specifications 3. TM 1003W Controls and Connections 4

Interchangeable thermistor (THE types) Output Contact E5CS-R1KJX-F E5CS-R1PX-F E5CS-R1GX-F Voltage E5CS-Q1KJX-F E5CS-Q1PX-F E5CS-Q1GX-F

XUBLAPCNL2 photo-electric sensor - XUB - thru beam - laser - Sn 100m VDC - cable 2m

2 General Application Photoelectric Sensors

Retroreflective sensor with polarization filter

Leuze electronic. Dimensioned drawing. Electrical connection. Accessories: 150m ISO 9001

2 General Application Photoelectric Sensors

panasonic.net/id/pidsx/global Lights up when conditions are normal (and at incipient liquid leak detection) Use as a warning Sensor

Optical system Beam shape Sensing distance Resolution*1 Model Diffuse reflective Spot beam 40±10 mm 2 µm ZX-LD40. Line beam 40±10 mm 2 µm ZX-LD40L

Polarized Retroflective Photoelectric Switches

OG-Cube Photoelectric Sensors Optical sensing technology

E3NX-MA. Smart Fiber Amplifier Units. Downsize control panels using the Omron dualchannel. Ordering Information

SensaGuard TM Integrated Latch Installation Instructions

APS-S/M Series. Polycarbonate Resin Square Type, 2-wire/3-wire DC System. Type. Proximity Sensor. Features

IQ-Sense. 2/2 Introduction. 2/3 IQ-Sense photoelectric sensors. 2/5 IQ-Sense ultrasonic sensors. 2/6 4 IQ-Sense sensor module for ET 200S

S15 SERIES. Ceramics. Beverage & Bottling

FACTORY AUTOMATION. Instruction Manual NBB20-L2-E2B-C-V1 NBN40-L2-E2B-C-V1 Inductive Sensor

/ / 2018

This symbol indicates prohibition. The specific prohibited action is provided in and/or around the figure.

TTSIM-2 TRACETEK SENSOR INTERFACE MODULE WITH LCD AND RELAY INSTALLATION/OPERATION INSTRUCTIONS

General Specifications

Type 2 safety light curtain Type 2 according to the IEC/EN parts 1 and 2 Compact profile: 31 x 32 mm 30 mm resolution for hand detection Wide r

SVP Series. Photoelectric Sensors Smart Value Photoelectric WARNING WARNING. MICRO SWITCH Sensing and Control. Introducing the NEW AC Version!

AX-100TFR/AX-200 TFR INTRODUCTION 1-1 BEFORE YOUR OPERATION BATTERY OPERATED PHOTOELECTRIC DETECTOR. Warning FEATURES. Caution. Warning.

Relationship between Air Volume and Particle Removal No. of 0.5 μm particles (per L) 800 Air volume 1 0.3m 3 /min 600

3NT SERIES FIXED TEMPERATURE THERMOSTATS Introduction

Fireray 2000 Linear Smoke Detector

PHOTOELECTRIC AMPLIFIER SERIES

Transcription:

PHOTOELECTRIC SENSORS EFA/B_-F Special family with inverted output logic Fully compatible with previous EF family Simple installation due to compact format Wide variety of models Ordering Information EFA/B straight types (PNP output) [Refer to Dimensions on page 8.] Red light Sensor type Connection method Model Plastic housing Metal housing Through-beam * pre-wired EFA-TP-F M EFB-TP-F M 0 m M connector EFA-TP-F EFB-TP-F Retro-reflective with MSR function * pre-wired EFA-RP-F M EFB-RP-F M 0. to m with E9-RS M connector EFA-RP-F EFB-RP-F Diffuse-reflective pre-wired EFA-DP-F M EFB-DP-F M 00 mm M connector EFA-DP-F EFB-DP-F 00 mm m 00 mm 00 mm m pre-wired pre-wired pre-wired pre-wired pre-wired EFA-DP-F M EFA-DP-F M EFA-DP-F M EFA-DP5-F M EFA-DP6-F M EFB-DP-F M EFB-DP-F M EFB-DP-F M EFB-DP5-F M EFB-DP6-F M M connector M connector M connector M connector M connector EFA-DP-F EFA-DP-F EFA-DP-F EFA-DP5-F EFA-DP6-F EFB-DP-F EFB-DP-F EFB-DP-F EFB-DP5-F EFB-DP6-F BGS pre-wired EFA-LP-F M EFB-LP-F M (background suppression) 00 mm M connector EFA-LP-F EFB-LP-F 00 mm pre-wired EFA-LP-F M EFB-LP-F M M connector EFA-LP-F EFB-LP-F * The set type includes the emitter and receiver. * The Reflector is sold separately. Select the Reflector model most suited to the application. Infrared light

EFA/B_-F ERA/B radial types (PNP output) [Refer to Dimensions on page 8.] Sensor type Connection method Retro-reflective with MSR function * Plastic housing Model Metal housing pre-wired ERA-RP-F M ERB-RP-F M Red light 0. to m with E9-RS M connector ERA-RP-F ERB-RP-F Diffuse-reflective pre-wired ERA-DP-F M ERB-DP-F M 00 mm M connector ERA-DP-F ERB-DP-F pre-wired ERA-DP-F M ERB-DP-F M 00 mm M connector ERA-DP-F ERB-DP-F * The Reflector is sold separately. Select the Reflector model most suited to the application.

Ratings and Specifications EFA/B_-F Straight type (EFA/EFB) Sensing method Through-beam Retro-reflective with MSR function Model PNP Pre-wired EF@-TP-F M EF@-RP-F M Item output M Connector EF@-TP-F EF@-RP-F 0 m 0. to m (with E9-RS) Spot diameter (reference value) Standard sensing object Opaque: mm dia.min. Opaque: 5 mm dia.min. Differential travel Directional angle min. Light source (wavelength) Red LED (6 nm) Red LED (6 nm) Power supply voltage 0 to 0 VDC (include voltage ripple of 0%(p-p) max.) Current consumption 0 ma max. ( 5 ma max. Receiver 5 ma max.) 5 ma max. Control output PNP (open collector) current: 00 ma max. (Residual voltage: V max.), power supply voltage: 0 VDC max. Operation mode Light-/Dark- selectable by wiring Indicator Power indicator (green): only of Through-beam Protection circuits Power supply reverse polarity protection, Output short-circuit protection, and Output reverse polarity protection Response time 0.5 ms Sensitivity adjustment One-turn adjuster Ambient illumination (Receiver side) Incandescent lamp:,000 lx max./ Sunlight: 0,000 lx max. Ambient temperature range Operating: -5 to 55 C/ Storage: -0 to 0 C (with no icing or condensation) Ambient humidity range Operating: 5 to 85%/ Storage: 5 to 95% (with no condensation) Insulation resistance 0 M min. at 500 VDC Dielectric strength,000 VAC at 50/60 Hz for min. between current-carrying parts and case Vibration resistance Destruction: 0 to 55 Hz,.5 mm double amplitude for hours each in X, Y and Z directions Shock resistance Destruction: 500 m/s times each in X, Y and Z directions Degree of protection IEC: IP6, DIN 0050-9: IP69K * Weight (packed state/only sensor) Material Accessories Pre-wired cable (M) Connector Case Lens and Display Adjuster Nut EFA: Approx. 0 g/ Approx. 50 g, respectively, EFB: Approx. 5 g/ Approx. 65 g, respectively EFA: Approx. 0 g/ Approx. 0 g, respectively, EFB: Approx. 85 g/ Approx. 0 g, respectively EFA: ABS, EFB: Nickel-brass PMMA POM EFA: POM, EFB: Nickel-brass Instruction sheet M8 nuts ( pcs) EFA: Approx. 60 g/ Approx. 50 g, EFB: Approx. 95 g/ Approx. 65 g EFA: Approx. 0 g/ Approx. 0 g, EFB: Approx. 50 g/ Approx. 0 g Instruction sheet M8 nuts ( pcs) * IP69K Degree of Protection Specifications IP69K is a protection specification stipulated by DIN 0050 Part 9 of the German standards. The test item is sprayed with 80 C water from a nozzle of a specified shape at a water pressure of 80 to 00 bar. The amount of water is to 6 liters per minute. The distance between the test item and the nozzle is 0 to 5 cm. The water is discharged at angles of 0, 0, 60, and 90 from the horizontal plane for 0 seconds at each angle while the test item is rotated horizontally.

EFA/B_-F Straight type (EFA/EFB) Sensing method Diffuse-reflective EF@-DP-F EF@-DP-F EF@-DP-F EF@-DP-F EF@-DP5-F EF@-DP6-F Model PNP Pre-wired M M M M M M output Item M Connector EF@-DP-F EF@-DP-F EF@-DP-F EF@-DP-F EF@-DP5-F EF@-DP6-F Spot diameter (reference value) 00 mm 0 5 mm of 00 mm 00 mm 0 50 mm of 00 mm m 0 50 mm of m 00 mm 0 5 mm of 00 mm 00 mm 0 50 mm of 00 mm m 0 50 mm of m Standard sensing object Differential travel 0% max. Directional angle Light source (wavelength) Red LED (6 nm) Infrared LED (850 nm) Power supply voltage 0 to 0 VDC (include voltage ripple of 0%(p-p) max.) Current consumption 5 ma max. Control output PNP (open collector) current: 00 ma max. (Residual voltage: V max.), power supply voltage: 0 VDC max. Operation mode Light-/Dark- selectable by wiring Indicator Protection circuits Power supply reverse polarity protection, Output short-circuit protection, and Output reverse polarity protection Response time 0.5 ms Sensitivity adjustment One-turn adjuster Ambient illumination (Receiver side) Incandescent lamp:,000 lx max./ Sunlight: 0,000 lx max. Ambient temperature range Operating: -5 to 55 C/ Storage: -0 to 0 C (with no icing or condensation) Ambient humidity range Operating: 5 to 85%/ Storage: 5 to 95% (with no condensation) Insulation resistance 0 M min. at 500 VDC Dielectric strength,000 VAC at 50/60 Hz for min. between current-carrying parts and case Vibration resistance Destruction: 0 to 55 Hz,.5 mm double amplitude for hours each in X, Y and Z directions Shock resistance Destruction: 500 m/s times each in X, Y and Z directions Degree of protection IEC: IP6, DIN 0050-9: IP69K * Weight (packed state/only sensor) Material Accessories Pre-wired cable (M) Connector Case Lens and Display Adjuster Nut EFA: Approx. 60 g/ Approx. 50 g, EFB: Approx. 95 g/ Approx. 65 g EFA: Approx. 0 g/ Approx. 0 g, EFB: Approx. 50 g/ Approx. 0 g EFA: ABS, EFB: Nickel-brass PMMA POM EFA: POM, EFB: Nickel-brass Instruction sheet M8 nuts ( pcs) * IP69K Degree of Protection Specifications IP69K is a protection specification stipulated by DIN 0050 Part 9 of the German standards. The test item is sprayed with 80 C water from a nozzle of a specified shape at a water pressure of 80 to 00 bar. The amount of water is to 6 liters per minute. The distance between the test item and the nozzle is 0 to 5 cm. The water is discharged at angles of 0, 0, 60, and 90 from the horizontal plane for 0 seconds at each angle while the test item is rotated horizontally.

EFA/B_-F Straight type (EFA/EFB) Sensing method BGS (Background suppression) Model PNP Pre-wired EF@-LP-F M EF@-LP-F M Item output M Connector EF@-LP-F EF@-LP-F 00 mm 00 mm Spot diameter (reference value) 0 0 mm of 00 mm 0 5 mm of 00 mm Standard sensing object Differential travel 0% max. Directional angle Light source (wavelength) Red LED (6 nm) Power supply voltage 0 to 0 VDC (include voltage ripple of 0%(p-p) max.) Current consumption 5 ma max. Control output PNP (open collector) current: 00 ma max. (Residual voltage: V max.), power supply voltage: 0 VDC max. Operation mode Light-/Dark- selectable by wiring Indicator Protection circuits Power supply reverse polarity protection, Output short-circuit protection, and Output reverse polarity protection Response time 0.5 ms Sensitivity adjustment Fixed Ambient illumination (Receiver side) Incandescent lamp:,000 lx max./ Sunlight: 0,000 lx max. Ambient temperature range Operating: -5 to 55 C/ Storage: -0 to 0 C (with no icing or condensation) Ambient humidity range Operating: 5 to 85%/ Storage: 5 to 95% (with no condensation) Insulation resistance 0 M min. at 500 VDC Dielectric strength,000 VAC at 50/60 Hz for min. between current-carrying parts and case Vibration resistance Destruction: 0 to 55 Hz,.5 mm double amplitude for hours each in X, Y and Z directions Shock resistance Destruction: 500 m/s times each in X, Y and Z directions Degree of protection IEC: IP6, DIN 0050-9: IP69K * * Weight (packed state/only sensor) Material Accessories Pre-wired cable (M) Connector Case Lens and Display Adjuster Nut EFA: Approx. 60 g/ Approx. 50 g, EFB: Approx. 95 g/ Approx. 65 g EFA: Approx. 0 g/ Approx. 0 g, EFB: Approx. 50 g/ Approx. 0 g EFA: ABS, EFB: Nickel-brass PMMA POM EFA: POM, EFB: Nickel-brass Instruction sheet M8 nuts ( pcs) * IP69K Degree of Protection Specifications IP69K is a protection specification stipulated by DIN 0050 Part 9 of the German standards. The test item is sprayed with 80 C water from a nozzle of a specified shape at a water pressure of 80 to 00 bar. The amount of water is to 6 liters per minute. The distance between the test item and the nozzle is 0 to 5 cm. The water is discharged at angles of 0, 0, 60, and 90 from the horizontal plane for 0 seconds at each angle while the test item is rotated horizontally. 5

EFA/B_-F Radial type (ERA/ERB) Sensing method Retro-reflective with MSR function Diffuse-reflective Model PNP Pre-wired ER@-RP-F M ER@-DP-F M ER@-DP-F M Item output M Connector ER@-RP-F ER@-DP-F ER@-DP-F 0. to m (with E9-RS) Spot diameter (reference value) 00 mm 5 0 mm of 00 mm 00 mm 0 5 mm of 00 mm Standard sensing object Opaque: 5 mm dia.min. Differential travel 0% max. Directional angle min. Light source (wavelength) Red LED (6 nm) Power supply voltage 0 to 0 VDC (include voltage ripple of 0%(p-p) max.) Current consumption 5 ma max. Control output PNP (open collector) current: 00 ma max. (Residual voltage: V max.), power supply voltage: 0 VDC max. Operation mode Light-/Dark- selectable by wiring Indicator Power indicator (green): only of Through-beam Protection circuits Power supply reverse polarity protection, Output short-circuit protection, and Output reverse polarity protection Response time 0.5 ms Sensitivity adjustment One-turn adjuster Ambient illumination (Receiver side) Incandescent lamp:,000 lx max./ Sunlight: 0,000 lx max. Ambient temperature range Operating: -5 to 55 C/ Storage: -0 to 0 C (with no icing or condensation) Ambient humidity range Operating: 5 to 85%/ Storage: 5 to 95% (with no condensation) Insulation resistance 0 M min. at 500 VDC Dielectric strength,000 VAC at 50/60 Hz for min. between current-carrying parts and case Vibration resistance Destruction: 0 to 55 Hz,.5 mm double amplitude for hours each in X, Y and Z directions Shock resistance Destruction: 500 m/s times each in X, Y and Z directions Degree of protection IEC: IP6, DIN 0050-9: IP69K * * Weight (packed state/only sensor) Material Accessories Pre-wired cable (M) Connector Case Lens and Display Adjuster Nut ERA: Approx. 60 g/ Approx. 50 g, ERB: Approx. 95 g/ Approx. 65 g ERA: Approx. 0 g/ Approx. 0 g, ERB: Approx. 50 g/ Approx. 0 g ERA: ABS, ERB: Nickel-brass PMMA POM ERA: POM, ERB: Nickel-brass Instruction sheet M8 nuts ( pcs) * IP69K Degree of Protection Specifications IP69K is a protection specification stipulated by DIN 0050 Part 9 of the German standards. The test item is sprayed with 80 C water from a nozzle of a specified shape at a water pressure of 80 to 00 bar. The amount of water is to 6 liters per minute. The distance between the test item and the nozzle is 0 to 5 cm. The water is discharged at angles of 0, 0, 60, and 90 from the horizontal plane for 0 seconds at each angle while the test item is rotated horizontally. 6

Output circuit diagram EFA/B_-F PNP Output Model EF@-TP@ EF@-RP@ EF@-DP@ ER@-RP@ ER@-DP@ Operation mode Light- Dark- Timing charts Light incident Light interrupted Operate Reset Operation indicator (orange) Output transistor (e.g., relay) Light incident Light interrupted Operate Reset Operation indicator (orange) Output transistor (e.g., relay) (Between blue and black leads) (Between blue and black leads) Operation selector Connect the (Pin()) to the brown (Pin()) or open the (Pin()) Connect the (Pin()) to the blue (Pin()) Operation indicator (Orange) indicator (Green) Photoelectric Sensor Main Circuit Output circuit Through-beam Receivers, Retro-reflective Models, Diffuse-reflective Models. Brown Light- Black Blue Pink 0 to 0 VDC Dark- 00 ma max. (Control output) (Relay) 0 V Through-beam Power indicator (green) Photoelectric Sensor Main Circuit Brown Blue 0 to 0 VDC EF@-LP@ Light- Dark- NEAR Operation indicator (orange) Output transistor (e.g., relay) Operate Reset NEAR Operation indicator (oramge) Output transistor (e.g., relay) FAR (Between blue and black leads) FAR Operate Reset (Between blue and black leads) Connect the (Pin()) to the brown (Pin()) or open the (Pin()) Connect the (Pin()) to the blue (Pin()) Background suppression. Operation indicator (Orange) indicator (Green) Photoelectric Sensor Main Circuit Brown Light- Black Blue Pink 0 to 0 VDC Dark- 00 ma max. (Control output) (Relay) 0 V Connector Pin Arrangement M Connector Pin Arrangement Connectors (Sensor I/O connectors) M -wire Connectors Pin No. Wire color Brown White Blue Black Classification Wire color Connector pin No. Application Brown ➀ Power supply (+V) DC White ➁ L/on D/on selectable Blue ➂ Power supply (0 V) Black ➃ Output

EFA/B_-F Dimensions Sensors (EFA/ERA Plastic housing) EFA series Pre-wired Models EFA-T@@ EFA-R@@ EFA-D@@ EFA-L@@ 5 5 (Unit: mm) Tolerance class IT6 applies to dimensions in this data sheet unless otherwise specified. Receiver 6.6 dia..5 dia. M8 0.5 P= Sensitivity adjuster * 8.5 0 dia. EFA-T@@ EFA-R@ EFA-D@@ EFA-L@@ 0.5 * EFA-T@@-D EFA-R@ EFA-D@@ Vinyl insulated round cable dia. cores (conductor cross sectional area:0.8 mm (AWG6) /insulation outside diameter:0.85 dia.) standard length m EFA series M Connector Models EFA-T@@ EFA-R@@ EFA-D@@ EFA-L@@ 5 5 Receiver 6.6 dia. 5.5 dia. M8 0.5 P= Right side view Sensitivity adjuster * 8.5 0 dia. 0.5 M P= EFA-T@@ EFA-R@ EFA-D@@ EFA-L@@ * EFA-T@@-D EFA-R@ EFA-D@@ Terminal No. Specification +V L/on D/on selectable 0V Output ERA series Pre-wired Models ERA-R@ ERA-D@@ Rear view Receiver. dia. M8 0.5 P= 5..9 5.9.. 5.9 8.5 0 dia. dia. ERA-R@ ERA-D@@ indicator (green) Sensitivity adjuster Vinyl insulated round cable dia. cores (conductor cross sectional area:0.8 mm (AWG6) /insulation outside diameter:0.85 dia.) standard length m ERA series M Connector Models ERA-R@ ERA-D@@ Rear view Receiver 5.. dia. M8 0.5 P=.9 5.9.. 5.9 8.5 0 dia. dia. ERA-R@ ERA-D@@ indicator (green) M P= Bottom view Sensitivity adjuster Terminal No. Specification +V L/on D/on selectable 0V Output 8

EFA/B_-F Sensors (EFB/ERB Metal housing) EFB series Pre-wired Models EFB-T@ EFB-R@@ EFB-D@@ EFB-L@@ Receiver.5 dia. M8 6. P= Sensitivity adjuster * 8.5 0 dia. EFB-T@ EFB-R@ EFB-D@@ EFB-L@@ 9.9 * EFB-T@-D EFB-R@ EFB-D@@ Vinyl insulated round cable dia. cores (conductor cross sectional area:0.8 mm (AWG6) /insulation outside diameter:0.85 dia.) standard length m EFB series M Connector Models EFB-T@ EFB-R@@ EFB-D@@ EFB-L@@ Receiver 8.5 dia. M8 6. P= Right side view Sensitivity adjuster * 8.5 0 dia. 9.9 M P= EFB-T@ EFB-R@ EFB-D@@ EFB-L@@ * EFB-T@-D EFB-R@ EFB-D@@ Terminal No. Specification +V L/on D/on selectable 0V Output ERB series Pre-wired Models ERB-R@ ERB-D@@ Rear view Receiver. dia. M8 6. P= 5. 5.9.8 50. 56.9 8.5 0 dia. dia. ERB series M Connector Models ERB-R@ ERB-D@@ ERB-R@ ERB-D@@ Rear view indicator (green) Sensitivity adjuster Vinyl insulated round cable dia. cores (conductor cross sectional area:0.8 mm (AWG6) /insulation outside diameter:0.85 dia.) standard length m Receiver. dia. M8 6. P= 5. 5.9.8 50. 60.9 8.5 0 dia. dia. indicator (green) ERB-R@ ERB-D@@ M P= Bottom view Sensitivity adjuster Terminal No. Specification +V L/on D/on selectable 0V Output 9

EFA/B_-F Safety Precautions Refer to Warranty and Limitations of Liability. WARNING This product is not designed or rated for directly or indirectly ensuring safety of persons. Do not use it for such a purpose. CAUTI Never use the product with an AC power supply. Do not use the product with voltage in excess of the rated voltage. Do not use the product with incorrect wiring. Otherwise, explosion, fire, malfunction may result. Precautions for Safe Use Be sure to follow the safety precautions below for added safety.. Do not use the sensor under the environment with explosive, flammable or corrosive gas.. Do not use the sensor under the oil or chemical environment.. Do not use the sensor in the water, rain or outdoors.. Do not use the sensor in the environment where humidity is high and condensation may occur. 5. Do not use the sensor under the environment under the other conditions in excess of rated. 6. Do not use the sensor in place that is exposed by direct sunlight.. Do not use the sensor in place where the sensor may receive direct vibration or shock. 8. Do not use the thinner, alcohol, or other organic solvents. 9. Never disassemble, repair nor tamper with the sensor. 0.Please process it as industrial waste. Precautions for Correct Use. Laying Sensor wiring in the same conduit or duct as high-voltage wires or power lines may result in malfunction or damage due to conduit or use shielded cable.. Do not pull on the cable with excessive force.. If a commercial switching regulator is used, ground the FG (frame ground) terminal.. The sensor will be available 00 ms after the power supply is tuned. Start to use the sensor 00 ms or more after turning the power supply. If the load and the sensor are connected to separate power supplies, be sure to turn the sensor first. 5. Output pulses may be generated even when the power supply is. Therefore, it is recommended to first turn the power supply for the load or the load line. 6. The sensor must be mounted using the provided nuts. The proper tightening torque range of EFA/ERA plastic housing series is between 0. and 0.5 N m. The proper tightening torque of EFB/ ERB metal housing series is 0 N m max.. ALL DIMENSIS SHOWN ARE IN MILLIMETERS. To convert millimeters into inches, multiply by 0.09. To convert grams into ounces, multiply by 0.05. OMR Corporation Industrial Automation Company Tokyo, JAPAN Contact: www.ia.omron.com Authorized Distributor: Regional Headquarters OMR EUROPE B.V. Sensor Business Unit Carl-Benz-Str., D-5 Nufringen, Germany Tel: (9) 0-8-0/Fax: (9) 0-8-99 OMR ELECTRICS LLC One Commerce Drive Schaumburg, IL 60-50 U.S.A. Tel: () 8-8-900/Fax: () 8-8-8 OMR ASIA PACIFIC PTE. LTD. No. 8A Alexandra Road # 05-05/08 (Lobby ), Alexandra Technopark, Singapore 996 Tel: (65) 685-0/Fax: (65) 685- OMR (CHINA) CO., LTD. Room, Bank of China Tower, 00 Yin Cheng Zhong Road, PuDong New Area, Shanghai, 000, China Tel: (86) -50-/Fax: (86) -50-00 OMR Corporation 0 All Rights Reserved. In the interest of product improvement, specifications are subject to change without notice. CSM 6_0 Cat. No. E00E-EN-0 Printed in Japan 0() 0