Performance Characteristics of Air-Conditioner Under Tropical Ambient Condition

Similar documents
Performance of R-22, R-407C and R-410A at Constant Cooling Capacity in a 10

A Study on Compression Characteristic of Wet Vapor Refrigerant

Performance Investigation of Refrigerant Vapor- Injection Technique for Residential Heat Pump Systems

Experimental Study on Match for Indoor and Outdoor Heat Exchanger of Residential Airconditioner

Effects of Flash and Vapor Injection on the Air-to- Air Heat Pump System

Some Modeling Improvements for Unitary Air Conditioners and Heat Pumps at Off-Design Conditions

Experimental Investigation of Closed Loop Oscillating Heat Pipe as the Condenser for Vapor Compression Refrigeration

Purdue e-pubs. Purdue University

Low GWP Refrigerants for Air Conditioning Applications

Performance Evaluation of Heat pump System using R32 and HFO-mixed Refrigerant in High Ambient Temperature.

Comparison of Performance of a Residential Air- Conditioning System Using Microchannel and Finand-Tube

Experimental Research On Gas Injection High Temperature Heat Pump With An Economizer

Design and Research of the Digital VRV Multi- Connected Units With Three Pipes Type Heat Recovery System

Experimental Investigation on Condensation Performance of Fin-and-Flat-Tube Heat Exchanger

Evaluation and Optimization of System Performance using HFO-mix Refrigerants for VRF and Mini-split Air-Conditioner

Introduction of Transcritical Refrigeration Cycle Utilizing CO2 as Working Fluid

Effects of Frost Formation on the External Heat Transfer Coefficient of a Counter-Crossflow Display Case Air Coil

Air-Cooled Heat Exchanger Performance for R410A

Improving Heating Performance of a MPS Heat Pump System With Consideration of Compressor Heating Effects in Heat Exchanger Design

Lower GWP Refrigerants Compared to R404A for Economizer Style Compressors

Feasibility of Controlling Heat and Enthalpy Wheel Effectiveness to Achieve Optimal Closed DOAS Operation

Development of R744 Two Stage Compressor for Commercial Heat Pump Water Heater

Performance Evaluation of the Energy Efficiency of Crank-Driven Compressor and Linear Compressor for a Household Refrigerator

Conceptual Design of a Better Heat Pump Compressor for Northern Climates

Development and Performance Measurements of a Small Compressor for Transcritical CO2 Applications

The Development Of High Efficiency Air Conditioner With Two Compressors Of Different Capacities

Comparison Of Hermetic Scroll And Reciprocating Compressors Operating Under Varying Refrigerant Charge And Load

Experimental Study on the Performance and Oil Return Characteristics of Multi-Split Air- Conditioning System for Medium Size Building

Compressor Capacity Control: A New Direction

Development of a Novel Structure Rotary Compressor for Separate Sensible and Latent Cooling Air-Conditioning System

Sub-Critical Operation of the CO2 Expander/ Compressor

System Using Exhaust Heat from Residential GHPs

The Innovative Green Technology for Refrigerators Development of Innovative Linear Compressor

Efficiency of Non-Azeotropic Refrigerant Cycle

Performance of CO2 Cycles with a Two-Stage Compressor

Load Sharing Strategies in Multiple Compressor Refrigeration Systems

Performance Comparisons Of A Unitary Split System Using Microchannel and Fin-Tube Outdoor Coils, Part I: Cooling Tests

Performance Analysis of a Miniature-Scale Vapor Compression System for Electronics Cooling: Bread Board Setup

Hunting Phenomena Of Automotive Air Conditioning Systems With Variable Displacement Compressor

Effect of Height Difference on The Performance of Two-phase Thermosyphon Loop Used in Airconditioning

Application of two hybrid control methods of expansion valves and vapor injected compression to heat pumps

Drop-in Testing of Next-Generation R134a Alternates in a Commercial Bottle Cooler/Freezer

Performance Measurement of R32 Vapor Injection Heat Pump System

The Effect of the Ventilation and the Control Mode on the Performance of a VRV System in Cooling and Heating Modes

Experimental Investigation on the Performance of Ground-source Heat Pump with the Refrigerant R410A

Dynamic Simulation of Liquid Chillers

R32 Compressor for Air conditioning and Refrigeration applications in China

Experimental Study About An Amount Of Oil Charge On Electric Driven Scroll Compressor For Electric Vehicle

Visualization of Evaporatively Cooled Heat Exchanger Wetted Fin Area

Refrigeration Cycle And Compressor Performance For Various Low GWP Refrigerants

Control Method Of Circulating Refrigerant Amount For Heat Pump System

Performance Characteristics and Optimization of a Dual-Loop Cycle for a Domestic Refrigerator- Freezer

Performance Comparison of R32, R410A and R290 Refrigerant in Inverter Heat Pumps Application

An Experimental Investigation Of Oil Retention Characteristics In CO2 Air-Conditioning Systems

Performance Evaluation of a Plug-In Refrigeration System Running Under the Simultaneous Control of Compressor Speed and Expansion Valve Opening

A Performance-Enhancing Additive for Vapor- Compression Heat Pumps: Additional Test Results

Study of R161 Refrigerant for Residential Airconditioning

High Efficiency R-134a Compressor for Domestic Refrigerator

Noise Reduction Technology With Porous Metal for Refrigerant Two-Phase Flow Through the Expansion Valve

EFFECT OF PAG OIL CIRCULATION RATE ON THE HEAT TRANSFER PERFORMANCE OF AIR-COOLED HEAT EXCHANGER IN CARBON DIOXIDE HEAT PUMP SYSTEM

The Development of the Energy-Saving Technology by the Composition Control of R407C

A study of high efficiency CO2 refrigerant VRF air conditioning system adopting multi-stage compression cycle

The Design Of A New Generation Of Twin Screw Refrigeration Compressors

Development of an Open Drive Scroll Compressor for Transportation Refrigeration

Heat Transfer of R-22 and Alternatives in a Plate- Type Evaporator

Performance Characteristic and Optimization of a Simultaneous Heating and Cooling Multi Heat Pump

Enhancement of the Separate Sensible and Latent Cooling Air-Conditioning Systems

Development Of 2-Cylinder Rotary Compressor Series For Light Commercial Use With R410A

An Analysis of a New Type Refrigeration Cycle (MICLOSS)

Effect of Modification in Refrigerant Passage of an Automotive Air Conditioning Compressor

Mini Vapour Cycle System For High Density Electronic Cooling Applications

Oil Return Measurements In A Unitary Split System Air Conditioner Using Different Refrigerant Mixtures

Experimental Study on the Performance of Twisted Capillary Tube

Transcritical CO2 Bottle Cooler Development

Design and Research of the Commercial Digital VRV Multi-Connected Units With Sub-Cooled Ice Storage System

Two-Step Capacity Modulation of a Single Cylinder Compressor

Development of Performance Test Facility of Positive Displacement CO2 Refrigerant Compressor

Performance of window air conditioner using alternative refrigerants with different configurations of capillary tube

Experimental Study on the Thermal Behavior of a Domestic Refrigeration Compressor during Transient Operation in a Small Capacity Cooling System

Experimental Study of Fouling Performance of Air Conditioning System with Microchannel Heat Exchanger

Capillary Tube and Thermostatic Expansion Valve Comparative Analysis in Water Chiller Air Conditioning

Diagnosing Troubles in Refrigeration Units with Screw Compressors

Analysis of Oil Pumping in the Hermetic Reciprocating Compressor for Household Refrigerators

Systematic Study of the Solution Properties of Low Global Warming Potential R-404A Replacement Refrigerant Blends with Various Polyol Ester Lubricants

Pressure Enthalpy Charts

Low Global Warming Refrigerants For Commercial Refrigeration Systems

ME 410 MECHANICAL ENGINEERING SYSTEMS LABORATORY MASS & ENERGY BALANCES IN PSYCHROMETRIC PROCESSES EXPERIMENT 3

Evaluation The Effect Of Washing On The Heat Transfer Capacity And Air-Side Flow Resistance Of Air Cooled Condensers

System Modeling of Gas Engine Driven Heat Pump

Design of Divided Condensers for Desiccant Wheel-Assisted Separate Sensible and Latent Cooling AC Systems

Modelling of an Integrated Supermarket Refrigeration and Heating System Using Natural Refrigerants

AHRI Low Global Warming Potential Alternative Refrigerants Evaluation Program (Low-GWP AREP) â Summary of Phase II Testing Results

Performance Characteristics of a Refrigerator- Freezer with Parallel Evaporators using a Linear Compressor

Compressor Capacity Control

Performance Enhancement of Refrigeration Cycle by Employing a Heat Exchanger

Purdue e-pubs. Purdue University. T. Hamada Mitsubishi Heavy Industries Ltd. N. Nishiura Mitsubishi Heavy Industries Ltd.

EXPERIMENTAL INVESTIGATION ON VARIABLE SPEED OPERATION OF AIR CONDITIONING

Experimental Analysis of a Stirling Refrigerator Employing Jet-Impingement Heat Exchanger and Nanofluids

Comparison of Energy Efficiencies of Commercial Refrigeration Direct and Indirect Systems

International Journal of Engineering Research (IJOER) [Vol-1, Issue-3, June- 2015]

Transcription:

Purdue University Purdue e-pubs nternational Refrigeration and Air Conditioning Conference School of Mechanical Engineering 2 Performance Characteristics of Air-Conditioner Under Tropical Ambient Condition A. K. Dutta Fujitsu General Limited K. Aritome Fujitsu General Limited Follow this and additional works at: http://docs.lib.purdue.edu/iracc Dutta, A. K. and Aritome, K., "Performance Characteristics of Air-Conditioner Under Tropical Ambient Condition" (2). nternational Refrigeration and Air Conditioning Conference. Paper 55. http://docs.lib.purdue.edu/iracc/55 This document has been made available through Purdue e-pubs, a service of the Purdue University Libraries. Please contact epubs@purdue.edu for additional information. Complete proceedings may be acquired in print and on CD-ROM directly from the Ray W. Herrick Laboratories at https://engineering.purdue.edu/ Herrick/Events/orderlit.html

PERFORMANCE CHARACTERSTCS OF AR-CONDTONER UNDER TROPCAL AMBENT CONDTON Asit Kumar DUTTA and Kenji ARTOME Engineering Department, Air-Conditioning Division, Fujitsu General Limited 193, Nakagawa, Hosoe-cho, nasa gun, Shizuoka-ken 431-134, JAPAN ABSTRACT Various types of compressor with different pumping mechanisms are available to use in the refrigeration cycle for the air-conditioner. However, an air-conditioner having the best performance compressor is recognized from the point of view of energy saving. n this study, the performance characteristics of an air-conditioner driven by different types of compressor are investigated under various ambient temperature conditions. Based on this study, the compressor suitable for the air-conditioner used in tropical ambient condition (high ambient air temperature) is suggested. 1. NTRODUCTON The air-conditioner capacity is usually decided either JS (Japan industrial institute) or AR (American refrigeration institute) standard condition. Under those conditions, for cooling operation, the ambient conditions, i.e. dry-bulb (db) and wet-bulb (wb) temperatures, at outdoor and indoor sides of the air-conditioner are 35 C/24 C (db/wb) and 27 C/19 C (db/wb) respectively. But, at each part ofthe globe, the outdoors-ambient temperature is quite different, which affects the air-conditioner performance. Many papers have been written with a view to improve system components, such as compressors [ 1,2] and heat exchangers [3,4], and optimizing complete systems [5,6]. However, it is not clear the performance of an air-conditioner using different types of compressor under high ambient air temperature. The aim of this paper is to investigate the performance of an air-conditioner using different types of compressor under tropical ambient condition, i.e. the ambient air temperature of above 35 C, without changing the indoor side room ambient condition. n the investigation, the compressors of reciprocating type, rotary type and scroll types of both high-pressure and low-pressure shells are used. 2. TESTNG EQUPMENT & TESTNG PROCEDURE For a designed air-conditioner, the discharge pressure changes by changing the ambient air temperature as the heat transfer capacity of the air-conditioner is decided under the certain testing condition. n this study, the performances of different types of compressor are investigated by varying the discharge pressure. Further the performances of an air-conditioner mounted with each type of compressor are examined under tropical ambient condition i.e. at high ambient air temperature. The testing equipment & testing procedure are described below: 2.1 Compressor Performance n this study, the compressors of reciprocating type, rotary type and scroll types of both high-pressure & low-pressure shells are taken for investigation. The compressors have the same capacity under AR compressor testing condition. The specifications of the compressors are shown in Table 1. Eighth nternational Refrigeration Conference at 377 Purdue University, West Lafayette, N, USA- July 25-28,2

n the experiment, the compressor is connected to the refrigeration cycle as shown in the Figure 1. Refrigerant discharged by the compressor is supplied to the air-cooled condenser where the refrigerant cools to liquid by rejecting heat to the ambient air. The liquid refrigerant, then, flows to the evaporator through an expansion valve. n the evaporator, the refrigerant evaporates by absorbing heat from the water, and it again sucked by the compressor. The evaporator is the shell & tube type heat exchanger in which the refrigerant flows to the tube and water is used as secondary medium. An electric heater was used to control the water temperature. EVAPORATOR CONDENSOR PRESSURE. GAUGE Fig. 1 Experimental setup for compressor performance test The electric power inputs of the compressor and the heater were measured with the digital power meters respectively. The suction and discharge pressures of the compressor were measured with the Brudon type pressure gauges, and the temperature at each point of the cycle was measured with the C-C thermocouple. Refrigerant R47C was used as a working fluid. The refrigeration cycle was operated at 5 rps and a steady operation of the cycle was maintained under the suction absolute pressure of.55mpa, and the suction superheat and the condenser subcool of 13 C and 8 C respectively. Data were recorded, for each compressor, at steady operation ofthe cycle under discharge absolute pressure of2.36mpa, 2.55MPa and 2.85MPa respectively. 2.2 Air-conditioner Performance The performance characteristics of an air-conditioner installed with different types of compressor were investigated by varying the outdoors ambient temperature. n the experiment, the split type air-conditioner with one indoor and one outdoor unit was used. The indoor unit consists of an air-cooled heat exchanger (so-called evaporator), and the outdoor unit consists of a compressor, an air-cooled heat exchanger (so-called condenser) and an expansion devise. The specifications of the tested air-conditioner are shown in Table 2. Figure 2 shows the experimental set up of the air-conditioner. n order to control the ambient conditions at the evaporator side and the condenser side of the air-conditioner, the indoor and the outdoor units were placed in two separate insulated rooms. The indoor side room ambient condition, i.e. dry-bulb (db) and wet-bulb (wb) temperatures of air, was maintained at JJS standard cooling condition by using an electric heater and a humidifier. On the other hand, a water-cooled fan coil unit and a humidifier were used to control the condenser side (outdoor unit) room ambient condition ( db/wb ). Table 1. Specification of the experimental compressors Compressor type Specification Scroll Recipro. Rotary L.P. shell H.P. shell Cooling capacity [ kw ] 7.6 7.6 7.6 7.6 Frequency [Hz] 5 5 5 5 Volt [ V] 24 24 24 42 Phase Single Single Single Three Table 2 Specification of the experimental air-conditioner Air-conditioner Air flow Heat exchanger rate Tube Fin Length Diameter Pitch Thickness m3/h [m] [m] [m] [m] Condenser side 259 48.893.18.11 Evaporator side 9 28.893.18.11 Eighth nternational Refrigeration Conference at Purdue University, West Lafayette, N, USA- July 25-28,2 378

n order to form a refrigeration cycle, both of the indoor and outdoor units were joined with the copper tubes. The electric power input (including the compressor and the fan motors of indoor and outdoor units) of the refrigeration cycle and the room heater were measured with the digital power meters respectively. The temperature at each point of the cycle was measured with the C-C thermocouples. Suction and discharge pressures of the compressor were measured with the Brudon type pressure gauges respectively. Qj t;::: :g E ::;, :r: Fig. 2 Wall... - ---. Outdoor,.._ ndoor i unit \j p/ unit.!!l ro :;::. rn ; : Room temperature ---- - 1 db: 35"C 48"C 1 wb:24 C - Room temperature db:27oc '... t= wb: l9 C Oi <J ;;:::: '6 Heater (.E : 8 ::J :r:..... Experimental setup for air-conditioner performance test n the experiment, the refrigeration cycle was operated at 5 rps, and at constant airflow through the evaporator and the condenser sides. The ambient conditions of both rooms were maintained at JS standard cooling condition [ evaporator and condenser sides rooms ambient air temperatures of 27oC/19oC (db/wb) and 35 C/24oC (db/wb) respectively l, and a steady operation of the refrigeration cycle was maintained under suction superheat and condenser subcool of 1 C and SoC respectively. Data were recorded at steady operation of the refrigeration cycle mounted with each type of compressor by varying only the condenser side (outdoor unit) room air temperature (db) of 35 C, 42 C and 48oC respectively. Refrigerant R47C was used as a working f1uid. 3. RESULTS AND DSCUSSONS Performance characteristics of an air-conditioner mounted with different types of compressor have been investigated under tropical ambient condition i.e. the outdoor air temperature of above 35 C. The investigation has been done in two ways. 1) Compressor performance 2) Air-conditioner performance 3.1 Compressor Performance The performances of different types of compressor have been investigated by varying the discharge pressure of 2.35MPa, 2.55MPa and 2.85MPa as the condensing pressure of the designed air-conditioner changes with the outdoor air temperature. n the investigation, the compressors of reciprocating type, rotary type and scroll types of both low-pressure and high-pressure shells are taken. The results are discussed below: Figure 3 shows the change of refrigerant mass flow rate (Gs) for each type of compressor with increasing the discharge pressure (P d). The mass flow rates Gs for each type of compressor are normalized by the value at the discharge pressure of 2.36MPa. Figure shows that, the mass flow rate Gs decreases with increasing the discharge pressure since the \ <'i 1. N.9 Recipro. comp. Rotary comp. 6. Scroll (H.P. shell) comp..a. Scroll {L.P. shell) comp. 2.2 2.4 2.6 2.8 3. Pd (MPa) Fig. 3 Mass flow rate of compressor under variable discharge pressure Eighth nternational Refrigeration Conference at Purdue University, West Lafayette, N, USA- July 25-28,2 379

refrigerant gas leakage from the compression pocket inside the compressor increases due to the increasing discharge pressure. But, the decreasing tendency of Gs for each type of compressor is quite different. The result is favorably good for the scroll type compressor with high-pressure shell as compared with the other compressors. This is due to the fact that, the scroll type compressor with high-pressure shell used in this experiment had a provision of oil injection in the compression pocket, which seems to decrease the internal gas leakage of the compressor. While, the compressors of reciprocating type and scroll type with low-pressure shell show the comparatively poor value of Gs at high discharge pressure. Figure 4 shows the change of electrical power input (L) of each type of compressor against the discharge pressure (P ct). The results of L for each compressor are normalized with each value at the discharge pressure of 2.36MPa. The electrical power input L for each compressor increases with increasing the discharge pressure due to the increasing compression power as well as the mechanical loss. But, the degree of increase for each compressor is quite different. For the scroll type compressors with both low-pressure and high-pressure shells, the results show the highest increasing slope while the increasing slope is comparatively low for the reciprocating type Recipro. comp.. < 1.3 f.o Rotary comp. N Fig. 4.6 Scroll (H.P. shell) comp. 1.2.& Scroll (L.P. shell) comp.!.9 L----'-----'---'--'-----'--------'-----'---l--'----_j 2. 2.2 2.4 2.6 2.8 3. Pd (MPa) Electric power input of compressor under variable discharge pressure compressor. This is because, for the scroll type compressor with low-pressure shell, the internal gas leakage between the compression chambers increases the compression power. On the other hand, for the high-pressure shell scroll type compressor, the dissociation of refrigeration gas from the injection oil increases the mass of refrigerant in the compression pocket, which increases the compression power. However, for the reciprocating type compressor, the power recovery due to the re-expansion of compressed gas in the clearance volume and the internal gas leakage tend to decrease the increasing tendency of the electrical power input. Based on the above results, the adiabatic efficiency TJ ad of each compressor is calculated, and the results are plotted against the discharge pressure (Pd) as shown in the Figure 5. The adiabatic efficiency ( TJ ad) is the ratio of the adiabatic work to the compressor electric power input. n the adiabatic work, the experimental values of, G,, are used as the values of refrigerant mass flow rate. The results of TJ ad for each compressor are normalized with each value at the discharge pressure of 2.36Mpa. Figure shows that, the adiabatic efficiency for each type of compressor decreases with increasing the discharge pressure due to the increasing compression power loss and mechanical loss. But, the decreasing tendency for each compressor is quite different. For the scroll type compressor with low-pressure shell, the adiabatic efficiency decreases steeply as compared with the adiabatic efficiency of other compressors. While, for the reciprocating type compressor, the decreasing tendency of adiabatic efficiency is fairly low due to the power recovery caused by the re-expansion of compressed gas in the clearance volume. 1.1,--,-----,-----,-,--.--,- 1-.---,---.-----, 1. N.9.8 erecipro. comp. "tl.; Rotary comp. ---...7.6Scroll(J.P. shell) comp. -g!=:".& Scroll(L.P. shell) comp..6 '---'--_j_----j.._l, j._.l, J 2. 2.2 2.4 2.6 2.8 3. Fig. 5 Pct (MPa) Adiabatic efficiency of compressor under variable discharge pressure Eighth nternational Refrigeration Conference at Purdue University, West Lafayette, N, USA- July 25-28,2 38

From the above results, it was clear that, the scroll compressor with high-pressure shell showed a good mass flow characteristic at high discharge pressure. However, from the viewpoint of adiabatic efficiency, the reciprocating type compressor showed the favorably good result among the compressors. By installing those compressors as a driving agent for an air-conditioner, the performances of an air-conditioner are investigated. 3.2 Air-conditioner Performance The performance characteristic of an air-conditioner operating with each type of compressor has been investigated by varying the outdoor air temperature while the indoor air temperature was kept constant. The results are discussed below: 2.5.. 6 2. 1.5 e Recipro. comp. Rotary comp. 6 Scroll (H.P. shell) comp. A Scroll (L.P. shell) comp. 1. L..L.-'-'--'--lL...L.._L L--'----'---'---'--'---'----'-----'----'---'---'-' 3 35 45 5 The changes of discharge pressure (P d) for an air-conditioner with different types of compressor are shown in the Figure 6 against the outdoor air temperature (Tair). The Figure indicates that, the discharge pressure P d increases with increasing outdoor air temperature. This is because of the decreasing heat transfer capacity of the condenser in the air-conditioner. The increasing values of P d for the air-conditioner with each type of compressor are almost the same at each outdoor air temperature. Fig. 6 Change of discharge pressure under variable outdoor air temperature [;.) 1.1,..---.--r---.--,.--r-.,-r---.--,-,---,-,---.-y---.--,----,--.--, tn ('<) 1.... iii.9 '<i:i o 8 e Recipro. comp. c; Rotary comp. d.7 -,.Scroll comp. (high pr. shell). Scroll comp. (low pr. shell). 6 '--'--'-'----'----'----'-...,-'----'-----'-----'----'-'----'-----'-----'----''--'---' Figure 7 shows the change of cooling capacity (Qc), electrical power input (L 1 ) and COP of an air-conditioner with different types of compressor operating under variable outdoor air temperature (Tair) The performance results for the air-conditioner with each type of compressor are normalized with each value at outdoor air temperature of35 C. The cooling capacity, Qc, as shown in the upper part of the Figure 7, decreases with increasing the outdoor air temperature, Tair, due to the decreasing heat transfer capacity of the condenser in the air-conditioner. Since the decreasing heat transfer capacity decreases the refrigerant enthalpy at the condenser outlet as well as increases the condensing pressure that deteriorates the mass flow rate of the compressor. But, the decreasing tendency of, Qc, for the air-conditioner with each type of compressor is different. At high outdoor ambient temperature, the air-conditioner mounted with scroll type [;.) 1.3 "iii 1.2 (:-< 1.1...r 1. 1. 4,-.--.---r-:--.-,--,--,----,---,-,--,-----,--.---r-:-y---r--,--,----.-...... 9 '-'----'----'----'----'-'-'----'---'---'-'--'---'---"-'-'--'--'--' p 1.1,-,-.,--,---,---,--,-,-,-.,--,--,-,--,---,--,.---,-,-,--.--r tn ('<) 11 1.... "«i --<.9...8 & u --.7 u. 6 i L...L._...L...L-'---'-'---'-'--'-'--'---'-'---L...L._-'--'----'----'-' 3 35 4 45 5 Tair [ C] Fig. 1 Air-conditioner performance under variable outdoor air temperature Eighth nternational Refrigeration Conference at Purdue University, West Lafayette, N, USA-.July 25-28,2 381

compressor with high-pressure shell shows favorably good cooling performance while, the cooling performance is comparatively poor for the air-conditioner mounted with reciprocating type compressor. The changes of electric power inputs, L> against the outdoor air temperature, Tair, are shown in the middle part of the Figure 7. The electric power input, Lr, for an air-conditioner with each type of compressor increases with increasing the outdoor air temperature due to the increasing discharge pressure caused by the decreasing heat transfer capacity of the condenser in the air-conditioner. The results of electric power input for the air-conditioner with each type of compressor show the same increasing tendency as the results of the compressor performance shown in the Figure 4. Based on the above results, the coefficients of performances (COP) ofthe air-conditioner mounted with each type of compressor are calculated, and the results are shown in the lower part of the Figure 7. The COP is the ratio of the cooling capacity, Qc, to the electrical power input L 1 The Figure 7 indicates that, the COP of an air-conditioner mounted with each type of compressor decreases with increasing the outdoor air temperature due to the decreasing both of the condenser and the compressor performances. However, at high outdoor air temperature, the air-conditioner driven by the reciprocating type compressor shows favorably good value of COP while, the value is comparatively poor for the air-conditioner driven by the scroll type compressor with low-pressure shell. 4. CONCLUSONS Performance characteristics of an air-conditioner were investigated under tropical ambient condition by using the compressors of reciprocating type, rotary type and scroll types of both high-pressure and low-pressure shells. The results are summarized as follows: 1. The condensing pressure of an air-conditioner increases with increasing the ambient air temperature, which decreased the mass flow rate and the adiabatic efficiency of the compressors. The mass flow characteristic for the scroll type compressor with high-pressure shell was favorably good as compared with the other types of compressor. However, from the point of view of adiabatic efficiency, the reciprocating type compressor showed favorably good value at high discharge pressure due to the. power recovery caused by the re-expansion of gas in the clearance volume. 2. The COP of an air-conditioner mounted with each type of compressor decreased with increasing the ambient air temperature due to the decreasing condenser and compressor performances. However, at high ambient air temperature, the air-conditioner driven by the reciprocating type compressor showed favorably good value of COP as compared with the compressors of rotary type and scroll types of both high-pressure and low-pressure shells. 5. REFERANCES 1) Yanagisawa, T., et al, Proceedings, 199 nternational Compressor Engineering Conference at Purdue, Vol. 1, pp. 222-231. 2) Hirano, T., 1993, Transactions ofthe Japanese Association ofrefrigeration, Vol. 1, pp. 227-238. 3) Holtzapple, M. T., 1989b, ASHRAE Transactions, Vol. 95, pp. 187-198. 4) Dutta, A. K., et al, Proceedings of Japan Society of Refrigeration and Air-conditioning Engineers (JSRAE), Nov. 4-5, 1997. 5) Fukushima. T., et al, 1977, Refrigeration, Vol. 52, pp. 31-314. 6) Endo, N., 1989, Journal ofmel, Vol. 52, pp. 27-4. Eighth nternational Refrigeration Conference at 382 Purdue University, West Lafayette, N, USA- July 25-28,2