Westken information manuals and technical assistance General Manual for Masterweld 15 Timer control system.

Similar documents
D3000. Installation & Setup Guide

RE-PR3-E-27 3-Phase Panel Mount 27kW

Digital Control Unit- Installation, Operation & Maintenance IMPORTANT INFORMATION

MANUAL. OEM (Unit) OZONE GENERATOR (100VA, 200VA and 300VA) INDEX

Ecoboiler T20 & T30 SERVICE MANUAL. Marco Beverage Systems Ltd. 63d Heather Road, Sandyford Industrial Estate, Dublin 18, Republic of Ireland

DIESEL ENGINE CONTROL UNIT DCU USER S MANUAL - N-2000 Lillestrøm, Norway Tel: (+47) Fax: (+47)

PRODUCT INSTRUCTIONS. Fire Door Control Panel (FDCP) Stock Code Description Doc No: PI-115. Ellard Fire Door Control Panel Ellard Slave Repeater Unit

SMARTELEC 2 ENERGY SAVING CONTROL INSTALLATION AND OPERATING MANUAL

UNDERCOUNTER SERVICE MANUAL. Ecoboiler UC4L 2.4kW Ecoboiler UC10L 2.8kW Ecoboiler UC10L 5.6kW Ecosmart UC4L 2.

Carbon Monoxide Transmitter

! WARNING To avoid risk of electrical shock, personal injury or death; disconnect power to dryer before servicing, unless testing requires power.

RTD TEMPERATURE SENSING SYSTEM

SERVICE MANUAL. Ecoboiler Model range: T20 ( ) T30 ( )

Sierra Series 900 Single & Dual Channel System. Instruction Manual

IMPORTANT SAFEGUARDS READ AND FOLLOW ALL SAFETY INSTRUCTIONS. HZM-Series-Class I, Div 2 Battery Unit. Instalation instructions

AQUARIUS 45 MARINE SERVICE MANUAL

Lubrication cycle IP Enclosure Rating. 110 VAC, 220/230 VAC (50/60 Hz) Alarm Fault Relay Contacts. IP-55 (Liquid tight connector)

Instruction Manual December 2001 ENACOCU02

ORP (mv) Controller Model: ORP-XP2. UP DOWN ENTER Time & Date Main Menu Alarm Reset

MYRIAD TRIPLEX PUMP CONTROLLER INSTRUCTION MANUAL

Rectifier RC-series. Manual RC-series English MA doc. Manual Wall and 19 English

IMPORTANT SAFEGUARDS READ AND FOLLOW ALL SAFETY INSTRUCTIONS. 3LERHZ Series Class I, Div 2 Combo Unit. Installation instructions

CaterSense 03 & ATSC-02-xx

Series DCT1000DC Dust Collector Timer Controller Specifications Installation and Operating Instructions

HPS-C-MULTI 6. Hotrunner Controllers. Operating manual. Valid for item numbers:

SERVICE MANUAL. Marco Beverage Systems Ltd. 63d Heather Road, Sandyford Industrial Estate, Dublin 18, Republic of Ireland

! WARNING To avoid risk of electrical shock, personal injury or death; disconnect power before servicing, unless testing requires power.

INSTRUCTION MANUAL. Laboratory Equipment Pty Ltd Ph: Fax:

NZ 400 AUTOMATIC FIRE ALARM SYSTEM OPERATORS MANUAL

WARNING FIRE DOOR CLOSING

Wallace & Tiernan Controllers & Analysers ChemTrim Disinfection Controller

APC BC300 Series 40kW 208/450/480V User Guide

Gas Safety Products. Installation, operating and maintenance 11/18/2015. Merlin 1000S+ Gas Utility & Electrical Isolation Controller

The EGT-1 is a single channel fully programmable digital EGT (Exhaust Gas Temperature) gauge.

Gas Safety Products. Installation, operating and maintenance 09/05/2016. Merlin CT1650+ Gas Interlock System. S&S Northern Ltd 1

Revision: None DCN No. First Issue Date: November 30, 1998 Product: Standard DCT, 120-volts

MODEL FPT-130 SINGLE POINT FREEZE PROTECTION HEAT TRACE CONTROL

OVEN INDUSTRIES, INC.

VERTEX VT10 SERIES PID OPERATION MANUAL MICROPROCESSOR BASED PID CONTROLLER

BL Series INSTRUCTIONS

Forced draught gas burner

BX444-Mc Gas Detector

SERVICE-MANUAL INDUCTION COOKER BASE-LINE/FAJITA HEATER SH/BA 3500 FH

R410A. WALL MOUNTEDtype INVERTER SPLIT TYPE ROOM AIR CONDITIONER. Models Indoor unit Outdoor unit AOYG07LEC AOYG09LEC AOYG12LEC AOYG14LEC

Gas Safety Products. Installation, operating and maintenance. Merlin 1000S+i Gas & Electric Utility Controller. Rev: 03 Date:

INSTALLATION AND USER MANUAL

PANEL_RS2. Run / Standby Panel. INSTALLATION MANUAL Version 1.02 MITSUBISHI ELECTRIC FOR INSTALLERS. Page 1 of 25

ELECTROPROJECT GTV-A POWER SUPPLY FOR DOOR MAGNETS

INSTALLATION INSTRUCTIONS FOR MODELS 16NG50-6/16LP50-6, 16NG60-6/16LP60-6, 20NG50-6/20LP50-6, 20NG60-6/20LP60-6, 26NG50-6/26LP50-6, 26NG60-6/26LP60-6

LaserRobot. Controller s User Manual. Hotline: Add: 1500xinfei Road No.72, Shanghai, China

Operator: Save these instructions for future use!

Instruction Manual August sitrans CU 02

Instructions for the hand-held micro terminal of the fan motor control system, TBLZ-2-75 SILVER C

MAINTENANCE & TROUBLESHOOTING GUIDE LEAK ALARM CHANNEL DRY OIL WATER AUX ALARM HIGH LOW CRITICAL WATER TANK LEVEL ALARM MODEL LDE-740 ADVANCE PAPER

Marco Beverage Systems Ltd.

DMG 973. Gas Burner Safety Control. For 2-stage forced draught and combi oil/gas burners, facility to connect an air damper unit

JW SERIES. Three Phase Thyristor Regulator PSE-351

Operating Instructions

Operator: Save these instructions for future use!

DEIF A/S. Description of options. Option A4, Loss of mains protection package Automatic Gen-set Controller. Description of option

Instruction Manual WARNINGS

OPERATING INSTRUCTIONS

GPPS-evo V3.3. Installation Instructions

OT-FX2 OLED TOUCH for the FX II Touch control panel OPERATOR S MANUAL. Technicold Marine Systems

L SERIES UNITS 504,520M. 10/2001 Supersedes 504,413M

SC-500 ENGINEER S MANUAL

GEYSERWISE INSTRUCTION MANUAL

SD2. Differential Controller. Operating and Installation Instructions F2 72.3

SERVICE INSTRUCTION R410A. WALL MOUNTEDtype INVERTER SPLIT TYPE ROOM AIR CONDITIONER. Models Indoor unit Outdoor unit AO*G24LFL AO*G24LFCC AO*G30LFT

Technicians Manual Single Compressor

# amp # amp 12/24 VDC POWER SUPPLY INSTALLATION MANUAL. 4202/4MA, Rev. E 0804

EXTINGUISHING AGENT RELEASE MODULE

Single Point Freeze Protection Heat Trace Control TRACON MODEL FPT 130 Installation and Operation Manual

Instruction Manual SCD24. Read this document prior to installation. Contents

X64 Wireless Training

Quick Reference. Air to Water Heat Pump Series 4 Lot 1 Standard & Powerful Types

SPLIT TYPE ROOM AIR CONDITIONER. WALL MOUNTEDtype INVERTER. Models Indoor unit Outdoor unit AOU 9RLFW1 AOU12RLFW1 ASU 9RLF1 ASU12RLF1 R410A

HP727S. Single speed swimming pool heat pump controller Operation manual TABLE OF CONTENTS

! WARNING To avoid risk of electrical shock, personal injury or death; disconnect power before servicing, unless testing requires power.

Instructions for the fan motor control system with integrated wiring terminals SILVER C

108A OTP1800. Grid Support. General Description

WALLACE & TIERNAN CONTROLLERS & ANALYSERS CHEMTRIM DISINFECTION CONTROLLER PRODUCT SHEET

EcoSmart boiler SERVICE MANUAL

INSTRUCTION FOR THE USER THC V E OIL BLU

Stand Alone DYNAGARD SP Operation Manual

MC200. Users Instructions. HEATING DIVISION Hort Bridge Ilminster, Somerset TA19 9PS Tel: Fax:

P1195 DUAL TOURNIQUET MONITOR

DMG 973. Gas Burner Safety Control. For 2-stage forced draught and combi oil/gas burners, facility to connect an air damper unit

DTS SECURITY P.O.BOX 3399 Base plate-mounting EDENVALE instructions 1610 TELEPHONE

AS DIGITAL FIRE PUMP CONTROLLER

FAULT CODES. Included in this section are instructions to Reset the two Hot Tank Overload Devices (High Safety Limit).

DMG 970. Gas Burner Safety Control. For 2-stage forced draught and combi oil/gas burners

Rev Pulse Modulating Anti- Sweat Control (PMAC II) Installation and Operation Manual

ProCon 16, 31, 47 & 75. RVA 63 Boiler and Circuit Controller Commissioning Data.

Wall Controller & Thermostat

CONTENTS Introduction and Characteristics. 1 Fire Alarm System Assembly Diagram.. 2 Fire Alarm Signal Flow Chart.. 2 Panel Descriptions 3 Standard

R410A. WALL MOUNTEDtype INVERTER SPLIT TYPE ROOM AIR CONDITIONER. Models Indoor unit Outdoor unit AO*G09LTCN AO*G12LTCN AO*G14LTCN

ESSEX ENGINEERING CORPORATION

Dual Technology Wall Mounted Occupancy Sensor. Manual & Specification

RC-112 Two Speed Heat Pump 3 Stage Heat / 2 Stage Cool With Energy Efficient Control

Transcription:

Instruction and programming/setup manual for the resistance welding "Masterweld 15" welding control timer systems. ( 08C Seam welding control) (02E Spot / Proj with Highlift welding control). ***Important Note*** Only use SCR units with single side cooling. Factory; Postal; Westken (West Kennett Corp) Westken, 191 Van Eden crescent, P.O.Box 52249, Rosslyn, Dorandia, Pretoria, 0182, South Africa. South Africa Tel; 0027 (0) 12 541 2188/9 Tel; 0027 (0) 12 541 6064/5 Fax; 0027 (0) 12 541 8086 Email; sales@westken.co.za, westkenpta@mweb.co.za, westkentech@mweb.co.za website; www.westken.co.za Revision (1.3) 010813 1

Content 1. "Masterweld 15" Features... 3 2. General technical data... 3 3. Instruction for use... 4 3.1 Function selection... 4 3.2 Basic set up instruction... 5 3.3 The welding process & Functions... 7 3.4 Set up of program parameters... 9 3.5 Wiring of initiation / program selection... 10 3.6 Open section... 11 3.7 Trouble shooting... 12 3.8 Safe use and general Precaution... 13 Appendix 1 Program Function Parameters... 14 Appendix 2 Layout for connections on P.C.B... 15 Appendix 3 User connections (08C) I.O. wiring diagram... 16 Appendix 3A User connections (02E) I.O. wiring Diagram... 17 Appendix 4 Internal wiring diagram... 18 Appendix 5 Internal air valve / solenoid circuit... 19 Appendix 6 Daisy Chain layouts... 20 Appendix 7 Open... 21 2

1. "Masterweld 15" features For spot / projection welders and, if installed, optional seam welder function. Welding quality assured by maintaining weld current regardless of mains voltage fluctuations and/or variations of welding load. The "Masterweld 15" uses a closeloop feedback system back to the welding controller. Either constant current or phased heat control options. Up to 15 selectable welding schedules. Single weld or stitch / repeat welding. Three fully settable and adjustable welding pulses per schedule. Weld pulsation availability. Current upslope and down slope function. Spot weld count function. Visual readout of mains incoming supply voltage. Visual readout of welding current (in constant current mode). Primary side current feedback. Self-diagnostic functionality indicated by fault "Alarm" codes. Data memory retention for up to ten years after supply power failure. Membrane switch facia programming. 2. General technical data For the function parameters: refer to (Appendix 1) Power Supply: Single phase AC380V, 50/60 Hz, +10%~-20% Ambient temperature: 0-50 Relative humidity: 90% Cooling water: inlet temperature 30 Water flow: 6L/MIN SCR: 500A/1200V 3

3. Basic set up instruction 3.1 Function selection The setting of dip switches ON position OFF position S1 Constant current "On" Phase heat "On" S2 Repeat On (stitch function) Repeat Off (Stitch function) S3 Pulse Starting initiation Normal Start initiation S4 Seam welding (optional 08C) Spot welding S5 S6 S7 15 program schedules 4 program schedules (dual gun mode) S8 External "Stop" Welding alarm External "Allow" Welding alarm 3.2 The programmer uses 3.2.1 There are two function "Modes" on the Masterweld 15. Either of the two modes can be selected by pressing the green mode button on the Programming Console. Program Run L.E.D Power on indicator "Mode" select " Program or Run" Selected Program Number Alarm Codes Information readout Parameter up / down Program Select Up/down Units select Selected unit Increase/decrease 1. Programming mode (Prog): Parameters can be programmed (see programming parameter list) 2. Welding mode (Run): Normal welding mode. Store unit information Second functions Highlighted in Yellow print 4

3.2.2 The controller displays information in either the programming or welding mode. While set up in programming mode the L.E.D,s will indicate information based on black print i.e. "pre-squeeze". During run mode the L.E.D,s will indicate information based on yellow print i.e. "SPOT COUNT". please note that only a number of the L.E.D,s carry yellow print. In run mode access is available to set up the constant current upper (CURR. LIMIT +), lower (CURR. LIMIT -) and reweld (REWELD) functions. Weld Counter Weld Counter X 1000 Welding current SCR Ratio Incoming Voltage Trans Supply Volts Current Limit Upper Current Limit Lower Auto Reweld On or Off 3.2.3 Set up to use the controller in Phase heat (Voltage compensation) mode. (1) At first power up i.e. first switch on, with controller set in phase heat (controller factory setup in phased heat on the dip switches). (2) The operator should weld once, then go to cool 1 (CONSTN. VOLT) (3) then press the green "ENTER" button. Please note; it is important that the above setup is carried out in the "Run" mode as indicated on the yellow prog/run panel 5

3.3 The welding process & functions 3.3.1 Pulse start is available when dip switch S3 is in the ON position Starting switch Valve 1 Welding current tl t2 t3 t5 t6 t7 t8 t9 t10 t4 Keep end signal 4 Cycles In w hich: tl: Initial squeeze t2: Squeeze t3: Ram up slope t4: Pre heat time t5: Cool time 1 t6: Weld time t7: Cool time t8: Temper time t9: Stop slope dow n 3.3.2 Pulse start is only available if S3 dip switch is "On" 3.3.2.1 Abort welding after initiate (system only locks in first weld cycle) Start switch Valv e 1 Welding current t1 t2 t3 t5 t6 t7 t8 t9 t10 Keep end signal t4 3.3.2.2 Continual welding after initiate (system locks in first weld cycle) Starting switch Valve 1 tl t2 t3 t5 t6 t7 t8 t9 t10 Welding current t4 Keep end signal 4 Cycles 6

3.3.2.3 Single weld operation (start switch held ON ) Starting switch Valve 1 Welding current t1 t2t3 t5 t6 t7 t8 t9 t10 t4 Output until switches cut off 3.3.2.4 Repeat or stitch welding. Starting switch Valve 1 Welding current Keep end signal t3 t8 t3 tl t2 t5 t6 t7 t9 t10 t11 t2 t5 t6 t4 t4 t1:pre Squeeze t2:squeeze t3:upslope t4:weld 1 t5:cool 1 t6:weld 2 t7:cool 2 t8:weld 3 t9:downslope t10: Hold t11:off 7

3.3.2.5 Seam welding (optional software upgrade O8 Version) 3.4 Set up of program parameters The Masterweld can undertake three welding pulses during each weld schedule in which the second pulse can be setup to repeat from one to nine times. If only single pulse welding is required then set cool1, cool2, weld1 & weld2 to 0 i.e. ZERO. Enter welding parameters as follows: (1) timing on the initial Presqueeze, squeeze, welding time, cooling time, hold time, off time is based on the "cycle" with a scale of 0-99 cycles Important note** At 50Hz, one cycle is 1/50 second; At 60Hz, one cycle is 1/60 second. (2) Welding current range scale of 20-199 where; 20 = approx 10% of available output current 199 = approx 100% available output current. (3) TRF (Transformer) turns ratio is V1/V2 V1 Primary voltage of welding transformer V2 Second voltage of welding transformer Turns ratio range can be 1.0 turn to 199.9 turns 8

(4) Open. (5) The over current limit (+) and the under current limit (-) is used to activate the alarm of out of range current. The setting of current is expressed by its percentage value between 5% (under current) and 20% (over current). When the actual welding current value is out of the over current limit (+) an alarm will be indicated by flashing fault code 95. When the actual value is out of the under current limit (-) and re-weld is set on, then the Masterweld will automatically reweld, if the weld it s still out of the under current limit (-) and If re-weld is not set on, an alarm will be indicated by flashing fault code 95 and the machine will not allow further welding to be undertaken. (6) Re-weld dip switch can be set either on/off in position 0 or 1 as follows; (7) Setting Upslope time. Position 0, re-weld is not permitted. Position 1, re-weld is permitted. If the time of weld1 is not set at 0 (Zero), then the total time of current upslope should not be more than the set time of weld 1; if the time of weld1 is 0 (zero), then the total time of current upslope should not be more than the set time of weld2. 3.5 Wiring of initiation / program selection Refer to Figure 2 The wiring diagram for user connection (CN2) terminal. As used on dual gun, multi welding head layouts. (1) Please note; 3 programmes are available on Version 02 4 programmes are available on Version 08: Valve 1 Valve 2 program 1 program 3 program 2 program 4 SW1 Ο X X X SW2 X X Ο X SW3 X O X X SW4 X X X Ο 9

(2) 15 schedule set up: using one air solenoid valve as used on single gun, pedestal and projection welding operations Schedule 1 3 5 7 9 11 13 15 2 4 6 8 10 12 14 S Ο Ο Ο Ο Ο Ο Ο Ο X X X X X X X W1 S X Ο X Ο X Ο X Ο O X Ο X O X Ο W2 S X X O O X X Ο Ο X O O X X Ο Ο W3 S W4 X X X X O O O Ο X X X Ο Ο Ο Ο (3) weld on / off switching can be made using user connection 2-B5 / 2-B7. When open; system operates without welding current being introduced into the weld area. When closed; the system operates with welding current being introduced into the weld area. 3.6 Open section 3.7 Trouble shooting 10

The "Masterweld 15" controller has self-diagnostic functions. Alarms codes are shown on the front L.E.D readout. These codes can be identified using the "Alarm codes" explanation block printed on the front of the controller. Reset alarm indication You can press key enter to reset alarm indication. Power Error alarm code 90, If the alarm light goes on again after resetting, possible meaning the system is seeing a low voltage on the incoming side. (1) Check incoming power supply wiring. (2) Check incoming power supply quality. (3) Check fuses. (4) if a fault cannot be found with the above then replace main P.C.B. SCR D.C alarm code 92, (1) Check the SCR gate and cathode leads are connected properly. (2) Check the thyristor firing circuits in the control panel. (3) Check for faults and/or problems with the SCR device. Power low alarm code 93, (1) Check incoming voltage / supply voltage. SCR / Transformer Thermostat alarm code 94, (1) Check SCR / Transformer cooling water s temperature and the water flows properly through the SCR device / Transformer cooling manifold. (2) That the duty cycle of the SCR device / Transformer is not being exceeded causing the SCR / Transformer to operate at a higher temperature that specified for the unit. (3) Whether the thermostat working properly. The thermostat is normally closed. 11

(4) Check for faults in the main control panel. (5) Check if the main welding transformer is running hot. If a alarm has been generated by over temperature in the above it will reset automatically on cool down. Once the system has reset it will be possible to re start the machine again. Low Current alarm code 95, If pre set weld current output is not achieved with the likelihood of bad welds being produced then please check as follows: (1) the pre set current upper limit is too high for the transformer to achieve. (2) the transformer turn ratio was incorrectly programmed during initial setup. (3) please note* upper limit factory set at + 20%. When the incoming voltage/current is unstable and susceptible to large fluctuations and/or if set welding current is too low please check as follows: (1) possible unstable incoming supply voltage. (2) if system uses high flexibility supply cables, shunts, jumper cables or kick less cables these maybe worn or damaged. (3) failure of insulation in the secondary circuit causing a short circuit or current/voltage leakage. (4) the pre set current lower limit is too low for the transformer to achieve. (5) the transformer turn ratio was incorrectly programmed during initial setup. (6) please note* lower limit factory set at - 10%. SCR Short alarm code 97, (1) The SCR is damaged and need to be replaced. (2) Measure the voltage on plug CN1, terminal 18 & 19, if voltage reading is Zero 0 the SCR is damaged, replace unit. (3) If the main P.C.B and/or the SCR interface card show damage then repair or replace the relevant damaged P.C.B. 12

Data Error alarm code 99, Data error covers faults due to Incorrect data input made during initial setup or programming or incorrect value inputs. 3.8 Safe use and general Precautions (1) Always ensure that the controller / welder installation is properly connected to earth. (2) only qualified and trained personnel should be allowed access to the internal workings of this equipment. This system is electrically "live" and the possibility of electric shock is ever present. (3) always electrically isolate the system when work is being undertaken on the system. (4) handling of parts and components on the panel by hand is prohibited. Components and parts may be damaged and/or destroyed by static electricity. (5) Don t touch, adjust or change the potentiometer (pots). These items are factory preset. (6) The control panel should never be used without a proper connection to the cooling water system. Cooling water flow and pressure should be tested and assured. The cooling water system should be checked regularly at monthly intervals the following items to be checked: A: Water is particle free, B: water flows smoothly C: water is at correct incoming temperature. D: system check for water leaks. (7) Monthly inspection. (After isolating the system) Check all terminals for tightness, hot joints, loose connections. Further inspection of the general condition of the wiring and equipment should also be undertaken at this time. 13

Appendix 1 Program Function Parameters Valve 1 Valve 2 Sc he dul e 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 Da ta ran ge Pre Squeeze (cycle) 0~99 Squeeze (cycle) 0~99 Upslope (cycle) 1~99 Weld 1 (cycle) 1~99 Heat or Current 1 ( 100A) 20~199 Cool 1 (cycle) 0~99 Weld 2 (cycle) 0~99 Heat or Current 2 ( 100A) 20~199 Cool 2 (cycle) 0~99 Weld 3 (cycle) 0~99 Heat or Current 3 ( 100A) 20~199 Down slope 0~99 Hold 1~99 Off 0~99 Transformer turns ratio 1~99 Welding Pulsations 1~4 Current limit + (upper) 5~99% Current limit - (lower) 5~99% Repeat on/off 0~1 14

Appendix 2 Layout for connections on P.C.B 15

Appendix 3 User connections (08C) I.O. wiring diagram 16

Appendix 3A User connections (02E) I.O. wiring Diagram A11 A10 A9 A8 B11 P2 B9 P3 B10 E STOP START P1 COM(OV) HIGH LIFT RESET ALARM RESET P4 REMINDING ALARM EOS HOLD END HI LIFT AV WELD AV A1 A2 A3 A4 A5 A6 A7 A8 A9 A10 A11 A12 A13 B1 B2 B3 B4 B5 B6 B7 B8 B9 B10 B11 B12 B13 COM (OV) WELD / TEST TRANSFORMER THERMAL SW. OUTPUT COM. OUTPUT COM. COM (VAL+) ALARM OUTPUT NOTE Terminals A3/A4/B3/B6/B7 are already connected to the main board O2E CR3 CR5 CR4 CR6 CR7 17

Appendix 4 Internal wiring diagram 18

Appendix 6 Daisy Chain 19

20