PM100V PM80V PM15V. Ex works. Depending on the specific range of application a regular ecalibration of the sensor head (PMU-V) has to be effected.

Similar documents
D Series Sensors for Humidity and Temperature Measurement With calibrated dmodul

A and B Series Sensors for humidity and temperature for digital transfer RS485 / MODBUS-RTU or RS232

A and B Series Sensors for humidity and temperature for digital transfer RS485 / MODBUS-RTU or RS232

Technical data Humidity Temperatur General data Electrical data Two designs duct version (LK) wall mounting

In order to minimize the impact of rain, snow, ice and solar radiation on the measurement the EE33-M must be mounted inside a radiation shield.

MELA Sensortechnik GmbH

Hygro and Hygrothermo Transducers (capacitive) for climatic applications

Duct Humidity and Temperature Transmitter. Features. IP65 protection. Ordering

Duct Humidity and Temperature Sensors 0-10 Vdc or 4-20 ma Outputs Passive sensor PT1000, PT100 NTC, NI1000 etc. Features. IP65 protection.

Hygro and Hygrothermal Transducers (Capacitive) for Air Conditioning Applications

Hygro/hygrothermal transducers (hygrometric)

Hygro/hygrothermal transducers (hygrometric)

Product data sheet AIRWIN BO-FK-120J Humidity sensors

Duct Sensors. Siemens Building Technologies HVAC Products. Symaro. for relative humitidy (high accuracy) and temperature

for relative humidity and temperature

Hygro Transducer, Hygrothermal Transducer, and CO 2 Measuring Probe for Building Management and Climate Monitoring

SENSE Instruments CO., LTD. Data sheet Gas detector Page 1 / 5. Gas detector

Specifications: ACCURACY: RH: ±1% Temperature: ±0.5 C. Dew point: Typically, +/-2.0C above 0C; +/-3.0C 0 to -60C OPERATING RANGE:

FTK+ Application. Types Available. Duct sensor for humidity and temperature. Datasheet

HYGROPHIL H process hygrometer

QFM21... Siemens Building Technologies HVAC Products. Symaro Duct Sensors. for relative humidity and temperature

Introduction Portable Meters Transmitter Probes RELATIVE HUMIDITY

QFM41.. Duct sensors QFM41.. AQF4150 AQF3153. Symaro. for relative humidity and temperature with calibration certificates

Silicon UVAB Sensor E xxx

EN - english. Instructions for installation and operation. Mobile humidity meter DP 207

Hygro Transducer / Hygrothermal Transducer and CO 2 Measuring Probe for Climate Monitoring

Version 1.6. Operating instructions HYDROMETTE BL COMPACT TF 2. Hydromette BL Compact TF 2

Pressure sensors. Ex ia I / IIC T6 acc. to ATEX. Features. Description. Measuring ranges. Applications

QFM21... Duct sensors. Symaro. for relative humidity and temperature

ExDetector IRCO2. ExDetector IRHC. Operating and Installation Instructions. Gas Detection and Warning Systems

Wind Alarm Instrument

THM80X Series Operation Manual Industry Degree Temp. & Humidity Transmitter V 0.1

Humidity Measurement Technology pros & cons. Helping you make a better measurement.

HUM-M2 Humidity Sensor Module Description

STT 3000 Series STT250 Smart Temperature Transmitters Specifications Models STT25T EN0l-6091 February 2009

Silicon Pyranometer GSM xx

WIO200 Water In Oil measuring instrument

It offers easy installation and the possibility for fast exchange of the sensor unit for service purposes.

QFM21... Duct Sensors. Building Technologies HVAC Products. Symaro. for relative humidity and temperature

Connection. e. g. Pt100. reference limit. yellow Output I. Composition

Type 5347 (TR/STL), Type 5348 (TR/ST) and Type 5349 (STM/STL) Double Thermostats

for relative humidity and temperature

DP 300 mobile dew point instrument

Model 5190-E Temperature/Humidity Probe

Relative Humidity Transmitters

QFM21... Duct Sensors. Siemens Building Technologies HVAC Products

Inductive Conductivity Measurement. Simultaneous display of conductivity/ resistance/salinity and temperature; large measurement symbol.

MP 601A Humidity Probe INSTRUCTION MANUAL

Selecting the right humidity sensor for your application

HYGRASREG RELIABLE PROTECTION AGAINST HUMIDITY FÜHLBARE PRÄZISION PRODUCT RANGE > Mechanical > Electronic > Guards

Temperature Measurement Transmitters for field mounting

FA compressed air plants (refrigeration/adsorption driers) - granulate driers - medical gases - non-corrosive gases, e. g.

Software Version 2.01 LEVEL MONITOR MODEL 220

ISOMETER IRDH375. Insulation monitoring device for unearthed AC, AC/DC and DC systems (IT systems)

for relative humidity and temperature with calibration certificates

HP 101A Series Humidity Temperature Probes INSTRUCTION MANUAL

Scanning Laser Range Finder Smart-URG mini UST-10LN Specification

Wind Alarm Instrument x.x0x

icountms Range Fluid Condition Monitoring Moisture Sensors

PCMini52 Digital RH & Temperature Mini Probe User s Manual

Model 5190-F Temperature/Humidity Probe

DMFPM-2R MULTIFUNCTIONAL

Innovation right to the point. Optical distance detection. Low cost and compact due to PMD technology.

02/11/2015

Differential Pressure and Flow Meter. Media 5 Indicator 160 Ø PN 50

CCD-Precision. Intelligent Laser-Optical Displacement Measurement. CCD System SENSORS & SYSTEMS. Authority in Displacement Measurement ILD 1800

Humidity Meters. hygrometers & therma-hygrometers. what is a hygrometer? applications. monitor humidity levels for better health. Humidity.

Operating Instructions for Limit switch Model: NBK-R NBK-RM NBK-RT NBK-RA

More Precision. indusensor // Linear inductive displacement sensors

Process Automation. Sensors and Systems: Level Sensors Level Switches Overfill Prevention Pressure Sensors Temperature Sensors

RS Pro Infrared Temperature Sensor

Room Sensors. Building Technologies HVAC Products ... Symaro. for relative humidity (high accuracy) and temperature

More Precision. indusensor Linear inductive displacement sensors

Duct Air Quality Sensors

Flame detector. The QRA4.U is for use with the following types of burner control:

Humidity Measurement Technology Pros & Cons. Helping you make a better measurement.

IT system floor-standing distribution

Snifter ATEX22 VERSION. User Manual. Distributor

DP-500. Target Flowmeter. Flow measurement of Gases and Liquids. Instrumentation for fluids

Temperature measurement with current output and PNP/NPN transistor switching output output 2 reprogrammable as switching output TS-400-LI2UPN8X-H1141

Instruction Manual Model A

Toroidal Conductivity Transmitters Series APT4000 Specifications

DP-500. Target Flowmeter. Flow measurement of Gases and Liquids. Instrumentation for fluids

STT 3000 Series STT250 Smart Temperature Transmitters Specifications Models STT25H, STT25S, STT25M, STT25D EN0I-6031 March 2010 Rev.

Hygro and hygrothermo transducers (capacitive) for HVAC monitoring

Sensors Transmitters. Pressure / Temperature / Humidity / Air velocity / Airflow / Air quality / Solar / Light. European Manufacturer

Potential Applications

More Precision. indusensor // Linear inductive displacement sensors

Capacitive leakage detectors of the Leckmaster range for installation in normally dry rooms

FAST RESPONSE TEMPERATURE SENSORS 42.11a

More Precision. indusensor // Linear inductive displacement sensors

Hygrostats (hygrometric)

1. Product description

ExDetector HC-100. Data Sheet. Gas Measuring and Alarm Systems

Thermo-hygrometer. Use and maintenance manual Update 3 Apr INSTUM_01378 Pag. 1/8

Gas cylinder scale Model GCS-1

Installation and operation manual DPC200 - DIFFERENTIAL PRESSURE CONTROLLER. Low pressure with PI-control-mode

Q-Series Relative Humidity and Relative Humidity & Temperature Sensors for Critical Environments and Outdoor Air

Dräger Polytron 8000 Stationary gas detector (EC)

UV Flame Supervision System

Transcription:

Galltec Mess- und Regeltechnik GmbH MELA Sensortechnik GmbH D-71145 Bondorf. Germany D-07987 Mohlsdorf-Teichwolframsdorf. Germany Tel. +49 (0)7457-9453-0. Fax +49 (0)7457-3758 Tel. +49(0)3661-62704-0. Fax +49(0)3661-62704-20 E-Mail: sensoren@galltec.de. Internet:www.galltec-mela.de E-mail:mela@melasensor.de. Internet: www.galltec-mela.de PM100V PM80V PM15V Description of the Sensor PM-V sensors with integrated hx-processor measure humidity by means of a humidity-dependant condenser. The capacitive Mela humidity measuring element, produced using thinfilm technology, consists of a base plate, on which the electrodes are housed and a hygroscopic polymer layer above it. The hygroscopic polymer layer absorbs water molecules from the medium to be measured (air) or releases them, thereby altering the capacity of the condenser. The humidity or temperature values measured are calculated in the eexchangeable PMU-V measuring head, with the calibration values stored there, and communicated on to the following electronic transmitter components as calibrated digital measuring values. The PMU-V measuring heads are calibrated and thus enable an easy replacement. Replaced measuring heads can be recalibrated in the factory. The transmitter with the hx processor uses the values of the relative humidity and the temperature to calculate the dew point temperature, the enthalpy, the mixing ratio, the absolute humidity or the wet-bulb temperature, in accordance with the laws of physics. The values are emitted at two analogue outputs with the standardised signals 0.10VDC, 0.1VDC, 0.20mA or (0) 4.20mA. The outputs can be configured differently and are defined using the software. Further measuring ranges on request. The Mela measuring element is protected by a filter and a basket guard. The PM-V is supplied with a ZE04 filter with PTFE protection (IP00). The sensors are designed for unpressurised systems, the measurement medium is non-aggressive air. Please consult the "application instructions for the sensing elements" (product info sheet no. A 1) or check with the manufacturer for further information which you need to bear in mind when using humidity sensors with capacitive sensing elements. 1) Ex works. Depending on the specific range of application a regular ecalibration of the sensor head (PMU-V) has to be effected. 2) Higher accuracies on request. 3) The accuracy of the calculated values depends on both the opera ting point in accordance with the hx diagram and on the primary values measured. 4) See load diagram PM-V Sensor for Humidity and Temperature with hx Processor with calibrated and exchangeable measuring head for direct output of various physical values Digital Head PMU-V Humidity measuring range... 0..100%rh measuring accuracy 10...90%rh at 23 C... ±1.5%rh 1)2) at <10%rh or >90%rh... ±2%rh at <10 C or >40 C... ±0.05%rh/K additional resolution... 0.01%rh (read out) hysteresis... < 1%rh Temperature measuring element... Pt1000 1/3DIN measuring range... -40...+85 C measuring accuracy... ±0.15 K at 23 C resolution... 0.01K (read out) influence of temperature (TK)... <0.005 K/K housing... stainless steel filter... ZE04 (standard)... ZE13 (optional) / IP65 Transmitter PMO...V with hx Processor physical outputs dew point temperature... 0...70 C 3) enthalpy... 0...80 kj/kg 3) mixing ratio... 0...100g/kg dry air 3) absolute humidity... 0...20g/m³ or 0...100g/m³ 3) wet-bulb temperature... -10...+50 C 3) relative humidity... 0...100%rh temperature ranges... -30...+70 C; 0...+50 C; 0...100 C There are respectively 2 physical values available at the output response time t 63 at v=2m/s... < 15 s electrical outputs voltage... 2x 0...1VDC, or 2x 0...10VDC current (PM80V and PM100V)... 2x 0(4)...20mA linearity... <0.25% power supply: PM80V + PM100V: 0...1V: 6... 30V DC / 24V AC ±10% 0... 10V: 15... 30V DC / 24V AC ±10% 0(4)... 20mA: 15... 30VDC 4) PM15V: 0... 1V: 6... 30VDC 0... 10V: 15... 30VDC electromagnetic compatibility... ref. EN61326-1 min. load resistance for voltage output... 10 kohm consumption of electronics... <10 ma load for current output... acc. diagram permissible ambient temperature at the sensor tube... -40...+85 C at the housing (PM80V)... -40...+85 C (PM100V)...-10...+60 C max. air speed... 15m/s minimum air speed across the measuring head for output: 2 x 0(4)...20mA... 1,5 m/s housing 2 x 0...1V, 2 x 0...10V... 1 m/s PMO100V... ABS light grey PMO80V... aluminium die-casting,varnished PMO15V... stainless steel protective system housing PM15V, PM80V... IP65 protective system housing PM100V...IP64 protective system connector... IP65 probe material... stainless steel mounting position... optional contacting... connecting terminals 1.5mm 2 in the housing PM15V length of connection cable... 1.5m This information is based on current knowledge and is intended to provide details of our products and their possible applications. It does not, therefore, act as a guarantee of specific properties of the products described or of their suitability for a particular application. It is our experience that the equipment may be used across a broad spectrum of applications under the most varied conditions and loads. We cannot appraise every individual case. Purchasers and/or users are responsible for checking the equipment for suitability for any particular application. Any existing industrial rights of predection must be observed. The perfect quality of our products is guaranteed under our General Conditions of Sale. Issue : December 2016 PM-V_E. Subject to modifications.

Type Survey PM-V page 2 Type Order No. value 1 value 2 PMU-V 630101023594 relative humidity 0...100%rh ASCII temperature -30...70 C ASCII "plug-and-measure unit" (digital) (-40...85 C) (digital) PM80V 740101023261 relative humidity 0...100%rh 0...20mA temperature -30...+70 C 0...20mA alu housing 740101023161 relative humidity 0...100%rh 0...20mA temperature 0...100 C 0...20mA 740101023061 relative humidity 0...100%rh 0...20mA temperature 0...+50 C 0...20mA 0...20mA 740305023261 dew point temperature 0...70 C 0...20mA temperature -30...+70 C 0...20mA 740410023261 enthalpy 0...80kJ/kg 0...20mA temperature -30...+70 C 0...20mA 740515023261 mixing ratio 0...100g/kg dry air 0...20mA temperature -30...+70 C 0...20mA 740621023261 absolute humidity 0...100g/m³ 0...20mA temperature -30...+70 C 0...20mA 740620023261 absolute humidity 0...20g/m³ 0...20mA temperature -30...+70 C 0...20mA 740833023261 wet-bulb temperature -10...+50 C 0...20mA temperature -30...+70 C 0...20mA PM80V 740101023271 relative humidity 0...100%rh 4...20mA temperature -30...+70 C 4...20mA alu housing 740101023171 relative humidity 0...100%rh 4...20mA temperature 0...100 C 4...20mA 740101023071 relative humidity 0...100%rh 4...20mA temperature 0...+50 C 4...20mA 740305023271 dew point temperature 0...70 C 4...20mA temperature -30...+70 C 4...20mA 4...20mA 740410023271 enthalpy 0...80kJ/kg 4...20mA temperature -30...+70 C 4...20mA 740515023271 mixing ratio 0...100g/kg dry air 4...20mA temperature -30...+70 C 4...20mA 740621023271 absolute humidity 0...100g/m³ 4...20mA temperature -30...+70 C 4...20mA 740620023271 absolute humidity 0...20g/m³ 4...20mA temperature -30...+70 C 4...20mA 740833023271 wet-bulb temperature -10...+50 C 4...20mA temperature -30...+70 C 4...20mA PM100V 750101023261 relative humidity 0...100%rh 0...20mA temperature -30...+70 C 0...20mA ABS housing 750101023161 relative humidity 0...100%rh 0...20mA temperature 0...100 C 0...20mA 750101023061 relative humidity 0...100%rh 0...20mA temperature 0...+50 C 0...20mA 750305023261 dew point temperature 0...70 C 0...20mA temperature -30...+70 C 0...20mA 0...20mA 750410023261 enthalpy 0...80kJ/kg 0...20mA temperature -30...+70 C 0...20mA 750515023261 mixing ratio 0...100g/kg dry air 0...20mA temperature -30...+70 C 0...20mA 750621023261 absolute humidity 0...100g/m³ 0...20mA temperature -30...+70 C 0...20mA 750620023261 absolute humidity 0...20g/m³ 0...20mA temperature -30...+70 C 0...20mA 750833023261 wet-bulb temperature -10...+50 C 0...20mA temperature -30...+70 C 0...20mA PM100V 750101023271 relative humidity 0...100%rh 4...20mA temperature -30...+70 C 4...20mA ABS housing 750101023171 relative humidity 0...100%rh 4...20mA temperature 0...100 C 4...20mA 750101023071 relative humidity 0...100%rh 4...20mA temperature 0...+50 C 4...20mA 4...20mA 750305023271 dew point temperature 0...70 C 4...20mA temperature -30...+70 C 4...20mA 750410023271 enthalpy 0...80kJ/kg 4...20mA temperature -30...+70 C 4...20mA 750515023271 mixing ratio 0...100g/kg dry air 4...20mA temperature -30...+70 C 4...20mA 750621023271 absolute humidity 0...100g/m³ 4...20mA temperature -30...+70 C 4...20mA 750620023271 absolute humidity 0...20g/m³ 4...20mA temperature -30...+70 C 4...20mA 750833023271 wet-bulb temperature -10...+50 C 4...20mA temperature -30...+70 C 4...20mA

PM-V page 3 Type Order No. value 1 value 2 PM80V 740101023211 relative humidity 0...100%rh 0...10VDC temperature -30...+70 C 0...10VDC alu housing 740101023111 relative humidity 0...100%rh 0...10VDC temperature 0...100 C 0...10VDC 740101023011 relative humidity 0...100%rh 0...10VDC temperature 0...+50 C 0...10VDC 740305023211 dew point temperature 0...70 C 0...10VDC temperature -30...+70 C 0...10VDC 740410023211 enthalpy 0...80kJ/kg 0...10VDC temperature -30...+70 C 0...10VDC 0...10VDC 740515023211 mixing ratio 0...100g/kg dry air 0...10VDC temperature -30...+70 C 0...10VDC 740621023211 absolute humidity 0...100g/m³ 0...10VDC temperature -30...+70 C 0...10VDC 740620023211 absolute humidity 0...20g/m³ 0...10VDC temperature -30...+70 C 0...10VDC 740833023211 wet-bulb temperature -10...+50 C 0...10VDC temperature -30...+70 C 0...10VDC PM80V 740101023221 relative humidity 0...100%rh 0...1VDC temperature -30...+70 C 0...1VDC alu housing 740101023121 relative humidity 0...100%rh 0...1VDC temperature 0...100 C 0...1VDC 740101023021 relative humidity 0...100%rh 0...1VDC temperature 0...+50 C 0...1VDC 740305023221 dew point temperature 0...70 C 0...1VDC temperature -30...+70 C 0...1VDC 740410023221 enthalpy 0...80kJ/kg 0...1VDC temperature -30...+70 C 0...1VDC 0...1VDC 740515023221 mixing ratio 0...100g/kg dry air 0...1VDC temperature -30...+70 C 0...1VDC 740621023221 absolute humidity 0...100g/m³ 0...1VDC temperature -30...+70 C 0...1VDC 740620023221 absolute humidity 0...20g/m³ 0...1VDC temperature -30...+70 C 0...1VDC 740833023221 wet-bulb temperature -10...+50 C 0...1VDC temperature -30...+70 C 0...1VDC PM100V 750101023211 relative humidity 0...100%rh 0...10VDC temperature -30...+70 C 0...10VDC ABS housing 750101023111 relative humidity 0...100%rh 0...10VDC temperature 0...100 C 0...10VDC 750101023011 relative humidity 0...100%rh 0...10VDC temperature 0...+50 C 0...10VDC 750305023211 dew point temperature 0...70 C 0...10VDC temperature -30...+70 C 0...10VDC 0...10VDC 750410023211 enthalpy 0...80kJ/kg 0...10VDC temperature -30...+70 C 0...10VDC 750515023211 mixing ratio 0...100g/kg dry air 0...10VDC temperature -30...+70 C 0...10VDC 750621023211 absolute humidity 0...100g/m³ 0...10VDC temperature -30...+70 C 0...10VDC 750620023211 absolute humidity 0...20g/m³ 0...10VDC temperature -30...+70 C 0...10VDC 750833023211 wet-bulb temperature -10...+50 C 0...10VDC temperature -30...+70 C 0...10VDC PM100V 750101023221 relative humidity 0...100%rh 0...1VDC temperature -30...+70 C 0...1VDC ABS housing 750101023121 relative humidity 0...100%rh 0...1VDC temperature 0...100 C 0...1VDC 750101023021 relative humidity 0...100%rh 0...1VDC temperature 0...+50 C 0...1VDC 750305023221 dew point temperature 0...70 C 0...1VDC temperature -30...+70 C 0...1VDC 0...1VDC 750410023221 enthalpy 0...80kJ/kg 0...1VDC temperature -30...+70 C 0...1VDC 750515023221 mixing ratio 0...100g/kg dry air 0...1VDC temperature -30...+70 C 0...1VDC 750621023221 absolute humidity 0...100g/m³ 0...1VDC temperature -30...+70 C 0...1VDC 750620023221 absolute humidity 0...20g/m³ 0...1VDC temperature -30...+70 C 0...1VDC 750833023221 wet-bulb temperature -10...+50 C 0...1VDC temperature -30...+70 C 0...1VDC

PM-V page 4 Type Order No. (PM-key) value 1 value 2 PMU-V 630101023594 relative humidity 0...100%rh ASCII temperature -30...70 C ASCII "plug-and-measure unit" (digital) (-40...85 C) (digital) PM15V 730101023211 relative humidity 0...100%hr 0...10VDC temperature -30...+70 C 0...10VDC cable version 730101023111 relative humidity 0...100%rh 0...10VDC temperature 0...100 C 0...10VDC 730101023011 relative humidity 0...100%rh 0...10VDC temperature 0...+50 C 0...10VDC 0...10VDC 730305023211 dew point temperature 0...70 C 0...10VDC temperature -30...+70 C 0...10VDC 730410023211 enthalpy 0...80kJ/kg 0...10VDC temperature -30...+70 C 0...10VDC 730515023211 mixing ratio 0...100g/kg dry air 0...10VDC temperature -30...+70 C 0...10VDC 730621023211 absolute humidity 0...100g/m³ 0...10VDC temperature -30...+70 C 0...10VDC 730620023211 absolute humidity 0...20g/m³ 0...10VDC temperature -30...+70 C 0...10VDC 730833023211 wet-bulb temperature -10...+50 C 0...10VDC temperature -30...+70 C 0...10VDC PM15V 730101023221 relative humidity 0...100%rh 0...1VDC temperature -30...+70 C 0...1VDC cable version 730101023121 relative humidity 0...100%rh 0...1VDC temperature 0...100 C 0...1VDC 730101023021 relative humidity 0...100%rh 0...1VDC temperature 0...+50 C 0...1VDC 0...1VDC 730305023221 dew point temperature 0...70 C 0...1VDC temperature -30...+70 C 0...1VDC 730410023221 enthalpy 0...80kJ/kg 0...1VDC temperature -30...+70 C 0...1VDC 730515023221 mixing ratio 0...100g/kg dry air 0...1VDC temperature -30...+70 C 0...1VDC 730621023221 absolute humidity 0...100g/m³ 0...1VDC temperature -30...+70 C 0...1VDC 730620023221 absolute humidity 0...20g/m³ 0...1VDC temperature -30...+70 C 0...1VDC 730833023221 wet-bulb temperature -10...+50 C 0...1VDC temperature -30...+70 C 0...1VDC Accuracy of humidity in %rh at 23 C Load for 0(4)...20mA current version Humidity %rh value of humidity %rh Load in Ohm RL - range PM-V current sensors Calibration values (humidity generator) Supply in VDC

ESD protection advice PM-V page 5 All PM15V sensors are made up of a PMO15V transmitter with a PMU-V sensor head and components which can be damaged by the effects of electrical fields or by charge equalisation when touched. This is why the PMU-V sensor heads, that can be supplied separately and that are suitable for being exchanged on location, are packaged in conductive, reusable ESD protected bags. The following protective measures must be taken when exchanging a PMU-V sensor head on the PMO15V transmitter: Before unpacking the PMU-V sensor head, ensure electrical potential equalisation between you and your environment. Pay particular attention to ensuring that this potential equalisation is maintained while you are e changing the PMU-V sensor head. Only store or transport the PMU-V sensor head in the ESD protective bag supplied, or in comparable packaging Connection diagrams PM80V, PM100V! The electrical connection must only be carried out by properly qualified personnel. Shielding PM80V Please fix the shielding for PM80V (with alu housing) in the cable gland (see photo). Connection diagram PM15V 2 -! The electrical connection must only be carried out by properly qualified personnel.

Humidity-Temperature Sensor PM100V with plastic housing IP64 48 210 PM-V page 6 Plug-and-Measure Unit "PMU-V" exchangeable 77 120 20 5 15 20 35,3 25 107 Bohrbild Gabarit de perçage Mounting drawing 80 5 68 Humidity-Temperature Sensor PM80V with housing made of aluminium die-casting IP65! The electrical connection must only be carried out by properly qualified personnel. 57 207 77 Plug-and-Measure Unit "PMU-V" exchangeable 75 4,8 16 15 63 Bohrbild Gabarit de perçage Mounting drawing 80 52 4,8 Humidity-Temperature Sensor PM15V in cable version 259 77 Plug-and-Measure Unit "PMU-V" exchangeable 15