Improving and Comparing the Coefficient of Performance of Domestic Refgirator by using Refrigerants R134a and R600a

Similar documents
PERFORMANCE OF VCRS SYSTEM WITH HEAT EXCHANGER AND PHASE CHANGE MATERIAL

A Review of Hydroflorocarbons (HFC S) Refrigerants as an Alternative to R134a Refrigerant

PERFORMANCE OF DEEP FREEZER BY USING HYDROCARBON BLENDS AS REFRIGERANTS

Subscripts 1-4 States of the given system Comp Compressor Cond Condenser E Evaporator vol Volumetric G Gas L Liquid

Experimentation and Fabrication of Iceplant Using Ecofriendly Refrigerant

Experimental Study on Performance Parameters for Refrigerants R22, R410a and R404a at Various Air Outlet Temperatures

NUMERICAL SIMULATION OF VAPOUR COMPRESSION REFRIGERATION SYSTEM USING REFRIGERANT R152A, R404A AND R600A

Role of Nano-technology for improving of thermal performances of vapour compression refrigeration system (VCRS): An Overview

Air Conditioning System with Modified Condenser Ducts and Evaporative Cooling

A Theoretical investigation on HC Mixtures as Possible Alternatives to R134a in Vapor Compression Refrigeration

NUMERICAL SIMULATION OF VAPOUR COMPRESSION REFRIGERATION SYSTEM USING REFRIGERANT R152A, R404A AND R600A

An Experimental Study of a Simple Vapour Compression Refrigeration System with Varying Parameters

EXPERIMENTAL INVESTIGATION OF WATER COOLER SYSTEM BY USING ECO-FRIENDLY REFRIGERANT (R-134a)

IJISET - International Journal of Innovative Science, Engineering & Technology, Vol. 2 Issue 12, December

Performance Analysis of Li-Br Water Refrigeration System with Double Coil Anti-Swirl Shell and Coil Heat Exchangers

Design of LPG Refrigeration System

DEEPAK PALIWAL, S.P.S.RAJPUT

Performance Evaluation of Eco- Friendly Alternate Refrigerants for VCRS

EVALUATION OF REFRIGERANT R290 AS A REPLACEMENT TO R22

Experimental study of Hydrocarbon Refrigerant Mixture R290/R600a as an alternative to Refrigerant R134a used in a Domestic Refrigerator

Thermodynamic study of R134a in Vapour Compression Refrigeration System in Summer Climate

International Journal of Informative & Futuristic Research ISSN (Online):

Performance Analysis of Electronic Expansion Valve in 1 TR Window Air Conditioner using Various Refrigerants

Part load performance analysis of vapour compression refrigeration system with hydrocarbon refrigerants

JJMIE Jordan Journal of Mechanical and Industrial Engineering

Performance Enhancement of Refrigeration Cycle by Employing a Heat Exchanger

Study of R-161 refrigerant as an Alternate Refrigerant to various other refrigerants

Thermodynamic Analysis of Cascade Refrigeration System Using R12-R13, R290-R23 and R404A-R23

International Journal of Multidisciplinary Research and Modern Education (IJMRME) ISSN (Online): (

Performance analysis of a vapour compression refrigeration system with a diffuser for theeco-friendly refrigerants R-134a, R-600a and R-152a

ASSESSMENT OF R430A REFRIGERANT AS A POSSIBLE SUBSTITUTE TO R134A REFRIGERANT IN LARGE CAPACITY FREEZER

EXPERIMENTAL INVESTIGATION OF COMPARISION OF AIR COOLED AND WATER COOLED CONDENSER ATTACHED WITH COOLING TOWER

Comparative assessment for drop in replacement of R134a in domestic refrigerator.

A Review on Analysis of Vapour Compression Refrigeration System Using Matrix Heat Exchanger

Performance Evaluation of R290 as Substitution to R22 & Mixture of Them in Vapour Compression Refrigeration System

Design and Fabrication of Liquefied Petroleum Gas Refrigeration System and Comparison with Domestic Refrigerator

Performance Evaluation of R290 as Substitution to R22 & Mixture of Them in Vapour Compression Refrigeration System

Comparative Performance Analysis of Domestic Refrigerator using R12, R134a and R600a Refrigerants

ISSN Electronic International Interdisciplinary Research Journal (EIIRJ) Bi-monthly Reviewed Journal Mar- April 2015

Performance Enhancement of Refrigeration Cycle by Employing a Heat Exchanger

PERFORMANCE OF A VERY LOW TEMPERATURE REFRIGERATION SYSTEM OPERATING WITH NATURAL FLUIDS

Experimental performance evaluation of heat pump by using CO 2. as a refrigerant. IOP Conference Series: Materials Science and Engineering

ADVANCES in NATURAL and APPLIED SCIENCES

EXERGY ANALYSIS OF DOMESTIC REFRIGERATOR WITH DIFFERENT REFRIGERANTS

Study of Performance of Binary Mixture of R134a and R161 as a Substitution of R134a in a Domestic Refrigerator

CHAPTER 1 INTRODUCTION

Enhancement of COP in Vapour Compression Refrigeration System

η second law = Second law efficiency

PERFORMANCE ANALYSIS OF VAPOUR COMPRESSION THERMOELECTRIC REFRIGERATION SYSTEM WITH NOZZLE AND DIFFUSER THROUGH INCORPORATION OF PHASE CHANGE MATERIAL

U.G. Student, Department of Mechanical Engineering, J D Engineering College, Nagpur, Maharashtra, India

Design and Fabrication of Water Refrigeration System by Creating Vacuum

A COMPARATIVE STUDY FOR RETROFITTING OF R-12 VAPOUR COMPRESSION REFRIGERATION SYSTEM BY ECO- FRIENDLY REFRIGERANTS R-134A, R-413A, R-423A

Volume 4, Issue 1 (2016) ISSN International Journal of Advance Research and Innovation

Effect of capillary diameter on the power consumption of VCRS using different refrigerants

Experimental investigation on the performance of air conditioner using R32 Refrigerant

EXPERIMENTAL INVESTIGATIONS ON AL 2 O 3 NANO REFRIGERANT WITH DIFFUSER AT CONDENSER INLET IN A VCR SYSTEM

Enhancement of COP using Nanoadditives in Domestic Refrigerator

Effects of evaporator load on vapour compression refrigeration system using ecofriendly hydrocarbon refrigerants with sub cooling

Oyelami S., Bolaji B. O.

International Journal of Engineering Research (IJOER) [Vol-1, Issue-3, June- 2015]

Department of MCE, Islamic University of Technology 2. Abstract

CHAPTER 1 INTRODUCTION

Australian Journal of Basic and Applied Sciences. Investigation of New Eco Friendly Refrigerant Mixture Alternative to R134a in Domestic Refrigerator

Experimental Evaluation of Refrigerant Mixtures as Substitutes for HFC134a

Experimental Investigation on R 290 and R 600a In a Vapor Compression Refrigeration

International Research Journal of Engineering and Technology (IRJET) e-issn: Volume: 04 Issue: 05 May p-issn:

Experimental Investigation of Hot water Fired R134A-DMAC VARS System at Various Heat Source Temperatures

REPLACING HARMFUL CFC 12 BY ECO-FRIENDLY REFRIGERANT IN MILK CHILLER

Design & Fabrication of Hybrid Cooler

Performance Assessment of Water Cooled Condenser Refrigeration System

DEVICE FOR EXTRACTING WATER FROM AIR

Enhancement of COP by Using Spiral and Microchannel Condenser instead of conventional Condenser of VCR System

Thermodynamics I. Refrigeration and Heat Pump Cycles

Experimental Investigations of Different Types of Condensers on the Performance of Household Refrigerators

ijcrr Vol 04 issue 07 Category: Research Received on:06/02/12 Revised on:17/02/12 Accepted on:02/03/12

FABRICATION OF REFRIGERANT FLOW RATE WITH SPIRALLY COILED CAPILLARY TUBE

Waghmare Tushar Ramrao, D.S.Nakate

PERFORMANCE OF REFRIGERATOR USING R-600A AS REFRIGERANT

Available online at ScienceDirect. Energy Procedia 109 (2017 ) 56 63

EXPERIMENTAL INVESTIGATIONS ON AUTOMOBILE AIR CONDITIONERS WORKING WITH R134a AND R290/R600a AS AN ALTERNATIVE

Optimum Length of a Condenser for Domestic Vapor Compression refrigeration System

Numerical Simulation of Window Air Conditioner

Performance Analysis of Domestic Refrigeration System with Thermoelectric Module

Evaluation of Vapour Compression Refrigeration System Using Different Refrigerants

International Journal of Research in Engineering and Innovation Vol-1, Issue-5 (2017), 68-72

Performance investigation of Air-conditioning system using ejector as expansion device

Use of fourth generation ecofriendly refrigerants in two and three cascade refrigeration systems for reducing global warming and ozone depletion

Volume 6, Issue 3(2018) ISSN International Journal of Advance Research and Innovation

IJESRT. Scientific Journal Impact Factor: (ISRA), Impact Factor: 1.852

Thermodynamic analysis of air cycle refrigeration system for Chinese train air conditioning

Keywords: Climate change; ozone depletion; Montreal protocol; eco-friendly refrigerant; hydrocarbon refrigerant; performance analysis.

CH2351 Chemical Engineering Thermodynamics II Unit V Refrigeration. Dr. M. Subramanian

Experimental Analysis Of Vapour Compression Refrigeration System With Superheating By Using R-134a, R-12, R-717 Refrigerant

Performance of an Improved Household Refrigerator/Freezer

Analysis of Vapour Compression Refrigeration System with Refrigerants R134a, R143a, R152a, R290 and R32

Thermodynamic Cycle Analysis of Mobile Air Conditioning System Using HFO-1234yf as an Alternative Replacement of HFC-134a

[Jhansi, 5(10): October 2018] ISSN DOI /zenodo Impact Factor

Volume 2, Issue 4 (2014) ISSN International Journal of Advance Research and Innovation

Experimental Investigation on Domestic Refrigerator by Shell and Tube Heat Exchanger after the Condenser Using Sub Colling of Refregaring Fluid

Experimental study of R600a and R436a to replace R134a in a domestic refrigerator and freezer

Transcription:

ISSN (e): 0 00 Vol, 0 Issue, 8 August 0 International Journal of Computational Engineering Research (IJCER) Improving and Comparing the Coefficient of Performance of Domestic Refgirator by using Refrigerants Ra and R0a Suresh Boorneni, A.V.Satyanarayana, Department of Mechanical Engineering, G.P.R College of Engineering, Andhra Pradesh, India) ASSOCIATE PROFESSOR (Department Of Mechanical Engineering, G.P.R College of Engineering, Andhra Pradesh, India) ABSTRACT The main objective in present dissertation has been focused on alternative refrigerant to conventional CFC refrigerant, CFC like R, R, Ra, etc are not eco friendly. The emission of these refrigerants causes the depletion of ozone layer etc. Hence to avoid above difficulty the alternative of refrigerant in the form of R0a has been choosing. R0a refrigerant are natural refrigerant consist of hydrocarbon. In the present work, the performance of the domestic refrigerator is determined using R0a (Isobutane) and comparison with Ra (Tetrafluoro-ethane) as the part of project work the refrigerator setup consists of evaporator, compressor, condenser and expansion valve are chosen with suitable specification. Also in the present work an attempt has been made to improve the coieffiecnt of performance (cop) of the system, by incorporating a heat exchanger before admitting refrigerant into the compressor. Thus the compressor work reduces and it may results increase the performance of the refrigeration system. KEYWORDS :Heat exchanger, coieffiecnt of performance, Isobutane, depletion of ozone, alternative refrigerants. I. INTRODUCTION Vapor compression Refrigeration system is an improved type of Mechanical refrigeration system. The ability of certain liquids to absorb enormous quantities of heat as they vaporize is the basis of this system. Compared to melting solids (say ice) to obtain refrigeration effect, vaporizing liquid refrigerant has more advantages. To mention a few, the refrigerating effect can be started or stopped at will, the rate of cooling can be predetermined, the vaporizing temperatures can be govern by controlling the pressure at which the liquid vaporizes. Moreover, the vapor can be readily collected and condensed back into liquid state so that same liquid can be recirculated over and over again to obtain refrigeration effect. Thus the vapor compression system employs a liquid refrigerant which evaporates and condenses readily. The System is a closed one since the refrigerant never leaves the system. The coefficient of performance of a refrigeration system is the ratio of refrigerating effect to the compression work; therefore the coefficient of performance can be increased by increasing the refrigerating effect or by decreasing the compression work.the Vapor compression refrigeration system is now-a-days used for all purpose refrigeration. It is generally used for all industrial purposes from a small domestic refrigerator to a big air-conditioning plant.. Statement of Problem The main components of refrigeration system are compressor, condenser, expansion valve and evaporator. In general refrigeration system the entire refrigeration circuit is exposed to atmosphere so that some losses may occur. So the entire refrigeration circuit is placed in the closed cabin. The emission of refrigerants like R, R, Ra etc are causes the depletion of ozone layer. So that the refrigerant R0a has been chosen because it is natural refrigerant consist of hydrocarbon and eco friendly. In the present dissertation work the heat exchanger is incorporated i.e. the capillary tube is insulated together with suction line of the compressor. So that the heat transfer occur between vapour refrigerant in the suction line and the liquid refrigerant in the capillary tube, so that some precooled liquid refrigerant can enter in to evaporator which is more efficient than regular refrigeration system. This change in temperature of liquid refrigerant entering in to evaporator will increase the coefficient performance of the system. www.ijceronline.com Open Access Journal Page

. objective of the work. Determining the actual coefficient of performance of domestic refrigerator using refrigerants R-a and R-0a.. Comparison the coefficient of performance of domestic refrigerators between refrigerants using R-a and R-0a.. Experiments increasing coefficient of performance of vapour compression refrigeration system by incorporating heat exchanger.. Comparison the coefficient of performance of domestic refrigerators between refrigerants using R-a and R-0a after incorporating heat exchanger. II. EXPERIMENTAL SETUP AND DESIGN DETAILS Different experimental and theoretical comparison is performed by many researchers to evaluate the performance of domestic refrigerator by using different refrigerants. In this experimental R-0a is compared with the R-a in a domestic refrigeration system. To perform the experiment L refrigerator is selected which was designed to work with R-a.it is consists of an evaporator, air cooled condenser, reciprocating compressor. Heat exchanger incorporating in system, capillary tube rounded on the entire suction line of system. By the process rounding of capillary to the suction line we reduce that external type of heat exchanger. Figure. Fabrication of Refrigeration Tutor before Heat Exchanger Incorporation Figure. Fabrication of Refrigeration Tutor after Heat Exchanger Incorporation III. EXPERIMENTAL PROCEDURE While coming experiment two types of refrigerant using in the refrigerator Ra & R0a,Putting the regulator at top position so that no need of cut-off easily taken for system..take down which refrigerant is in application. Take down the energy meter reading no of seconds for revolution of energy meter Take down the reading of compressor pressure discharge inlet & condenser outlet from the pressure gauges. Take down the temperature readings of compressor suction line, discharge temperature, temperature of evaporator and condenser outlet temperature of system. Calculate coefficient of performance & energy consumption. And the experiment is repeated for other refrigerant and the readings are tabulated in the tabular column. www.ijceronline.com Open Access Journal Page

IV. RESULTS AND DISCUSSION Table reading taken from the experimental procedure of Ra refrigerant placed in the experimental setup. Note the reading of compressor inlet, compressor outlet condenser outlet, evaporator temperature pressure & of various parameters in the setup. N (rev/sec) :0 : :00 9:00 Table. Reading of Ra Refrigerant without Heat Exchanger T T T P P c c c -. -.9-9. -.9. 0 0.8 0. 0. 0. 9. 0... P 9. 9..0.0..0..8 Table. Reading of Ra Refrigerant with Heat Exchanger N T T T P P (rev/sec) c c c :0 9:8 0:0 9:9 :0 : -.9 -.9-9. - - -.8-9.8.9. 8. 9........ 0.8 0. 0.8 0.8 0. 0. 0.0....8...8 P...0..8.8....0.9.8..0 Table reading taken from the experimental procedure of R0a refrigerant placed in the experimental setup. Note down reading as per procedure placed. Table. Reading for R0a without Heat Exchanger N T T T P P (rev/sec) c c c -0. -. -. -. -.8 -. -8..9..8. 8. 9....9.8. 0. 0. 0. 0.08 0.08 9. 8.9 9. 8.0 8. 8.9 P 8. 8..9.9.9......9.8..08 Table. Reading for R0a Refrigerant with Heat Exchanger T T T P P c c c N (rev/sec) :0 :0 : :0 :0 :09 :0 -. -.9 -.9 -. -. -9. -9..9....... 9.. 9. 8 9. 8. 0. 0. 0. 0.0 0.0 0.0 8. 8. 8. 8.0.9.. P.9.9.9.9.8....9....0.0 www.ijceronline.com Open Access Journal Page

Figure. Shows R0a refrigerant Evaporator V s Colour Represent in graph Green colour : refrigerant with H.E Red colour : refrigerant without H.E Figure. Shows Ra refrigerant Evaporator V s Figure. Represent R0a evaporator Temp V s Discharge Temp www.ijceronline.com Open Access Journal Page

Figure. Represent Ra evaporator Temp V s Discharge Temp V. CONCLUSIONS An experiment is conducted on domestic refrigerator by with & without incorporating heat exchanger in the system by using various refrigerants in the fabrication system and their coefficient of performance & energy consumption of the system is calculated. Refrigerator carried out using without & with heat exchanger of refrigerant Ra & R0a in system, in which coefficient of performance of refrigerator 0.9 increased by using heat exchanger. In the same way the discharge temperature of compressor is decreased with 0% by using heat exchanger, energy consumption refrigerator gradually increased with % of compared to normal domestic refrigerator. REFERENCES [] R. Yajima et al., 99, "The Performance Evaluation of HFC Alternative Refrigerants for HCFC-", IIR Joint meeting, CFCs The Day After, Padova [] K. Furuhama et al., 99, "Performance Evaluation of Residential Air Conditioner with HFC/ Mixture, The International Symposium HCFC Alternative Refrigerants, Kobe [] E. Johnson, Global warming from HFC, Environ. Impact Assessment Rev. 8 (998) 8 9. [] M.A. Hammad, M.A. Alsaad, The use of hydrocarbon mixtures as refrigerants in domestic refrigerators, Applied Thermal Engineering 9 (999) 8 89. [] Douglas J D, Braun J E, Groll E A and Tree D R (999), A Cost Method Comparing Alternative Refrigerant Applied to R - System, International Journal of Refrigeration, Vol., pp. 0-. [] B. O. Bolaji, Experimental study of Ra and R to replace Ra in a domestic refrigerator, Energy (00) 9 98. www.ijceronline.com Open Access Journal Page