Installation, Operation & Maintenance Instructions

Similar documents
Armstrong J Series Float, Thermostatic Steam Traps, Condensate Controllers & Liquid Drainers Installation and Maintenance Manual

Series 1140 and 1141 Temperature Regulators

Technical Data TYPE T14 & T14D TEMPERATURE PILOT SPENCE ENGINEERING COMPANY, INC. 150 COLDENHAM ROAD, WALDEN, NY SD 4511A T14 PILOT

Installation, Operation and Maintenance Guide G3600 Series Thermostatic Mixing Valves

Installation and Maintenance "L" and "LS" Series

SuperKlean Washdown Products

Page 1 of 18. Part# /5/2013

F-P, F-L, FT-P AND FT-L SERIES 2/3 JACKETED DIRECT STEAM TILTING & STATIONARY KETTLES PARTS AND SERVICE MANUAL

568X, 587X, 588X Series

TECHNICAL DATA. Wet 26a. February 22, 2009

Disposal Unit (BKSDU) Burger King Shortening. Operation, Service & Parts Manual BURGER KING BKSDU

INSTALLATION, OPERATION

Installation Manual CARBONATOR With Plain-Water Booster

Heat Exchanger Block Replacement Instructions

Liquid Drainers LIQUID DRAINERS

Instructions for Installation, Operation, Care and Maintenance

AIC Series Float & Thermostatic Steam Trap Installation and Maintenance Instructions

INSTALLATION, OPERATION

KPS-DS, KLS-DS, KPT-DS AND KLT-DS SERIES 2/3 JACKETED DIRECT STEAM TILTING & STATIONARY KETTLES PARTS AND SERVICE MANUAL

INSTALLATION ADJUSTMENT SERVICE

OUTLET HOT INLET COLD INLET INSTALLATION

INSTALLATION ADJUSTMENT SERVICE TYPE TM-15, TM-20, TM-20-LF (As furnished with models TM-554, TM-356, TM-356-W/HA)

ICS Float and Thermostatic Steam Trap Installation and Operation Manual

TA-300, TA-300-LF, TA-350, TA-350-LF

Domestic Pump Vacuum and Boiler Feed Units Series VCMD TM INSTRUCTION MANUAL DN0137 REVISION F

MODELS R & RH 10 THRU 20 RB SERIES ELECTRIC STEAM BOILERS

CSD-1 CRN Electra Steam, Inc. Instruction Manual for JR06 Steam Generator, JG- and JJ- Models

Operating Manual. Model: Float-Controlled Condensate Trap, PN Safety instructions. 2 General description and usage

Troubleshooting the MPH 24FP Series Pedestal Hydrant

PT15 MATERIAL : DIMENSIONS - Nominal in inches. AVAILABLE SPARES: Disc (Packet of 5) ORDERING INFORMATION: Refer to "HOW TO ORDER" page.

Model: 1413 Model: 1418 Float-Controlled Condensate Trap, PN 100

Condensate Pumps Jones Boulevard Limerick Airport Business Center Pottstown PA Tel:

Operating Manual. Model: 1400 Model: 1400-N RIFOmat Float-Controlled Condensate Traps, PN Safety instructions. 2 General description and use

Note: Please provide valve serial number (stamped on cover of valve) when ordering parts. Thermometer. Hot Water Inlet. Cold Water Inlet G3600LF

690 and Power Fishing Systems

INSTALLATION, OPERATION & MAINTENANCE MANUAL FOR DRY PAK PACKAGED COMPRESSED AIR TREATMENT SYSTEM MODEL: DPP-150 WARNING

Silhouette. Feedwater Heater. Boiler Feedwater

569, 570, 571, 572 Series

INSTALLATION INSTRUCTIONS

OWNER'S SERVICE MANUAL NO INSPECTION, MAINTENANCE AND RECHARGE

! WARNING. Replacement Head Mechanism INSTRUCTION MANUAL MM-413F

FRESH HEAD. MANUAL TOILET for pressurized fresh water rinse INSTALLATION AND MAINTENANCE INSTRUCTIONS

Autotrol Performa FA Valve

TEMPERATURE CONTROLLERS

OWNER S MANUAL. Models: Herkules Equipment Corporation 2760 Ridgeway Court Walled Lake, MI USA Fax

HT650 TM FAN DRIVE SERVICE INSTRUCTIONS

MTC-Series Manual Trash Compactors Instruction Manual

TITAN FLOW CONTROL, INC.

TECHNICAL INSTRUCTIONS

Patterson/AMT Inline Circulator Pump Refer to pump manual for General Operating and Safety Instructions.

F-CLASS MODEL M6L WET CHEMICAL FIRE EXTINGUISHER Installation, Operation, Recharge and Maintenance Manual

INSTALLATION, OPERATION

Detailed Cleaning Instructions

Model: 1100 Float-Controlled Condensate Trap, PN 25

INSTRUCTION MANUAL DN0136 REVISION D

A/C COMPRESSOR OIL CHECKING

DRY AIR SYSTEMS, INC Metro Boulevard Maryland Heights, Missouri (314) fax (314)

FIGURE 1: MODEL UMC MANIFOLD CHECK ASSEMBLY MATERIALS OF CONSTRUCTION

INSTALLATION ADJUSTMENT SERVICE TYPE TM-15, TM-20* (As furnished with models TM-554, TM-356, TM-356-W/HA Valve is ASSE 1017 listed

Model LF-210 Air Operated

569, 570, 571, 572 Series

REIMERS ELECTRA STEAM, INC. INSTRUCTION MANUAL JG & JJ MODELS Serial No.:

MODELS N150/300/675/900/1500/2500/2600 INSTALLATION, SERVICING AND MAINTENANCE INSTRUCTIONS

Technical Data. Sizes 2 in. (DN50) to 16 in. (DN400) Approvals UL and ULC Listed FM Approved

Operation & Maintenance Manual

TROCADERO ORDERING INFORMATION NOTES T01-H INSTALLATION INSTRUCTIONS

PURPLE K POWDER EXTINGUISHERS INSTALLATION, OPERATION, MAINTENANCE AND RECHARGE MANUAL

Installation S

Series 47 and 247 Mechanical Water Feeders. Series 47-2 and Combination Mechanical Water Feeder/Low Water Cut-Off ! WARNING

Worldwide Contacts. Technical Data

WAL-RICH CORPORATION SINCE 1950

Getz Equipment Innovators 450 lb Dual Portable Dry Chemical Fill System

Patterson/AMT Inline Circulator Pump Refer to pump manual for General Operating and Safety Instructions.

Installation S

OPERATING AND MAINTENANCE MANUAL FOR PLATE HEAT EXCHANGER INDIRECT FIRED WATER HEATER. Electric Heater Company Base Model "BWXP"

REVE ORDERING INFORMATION NOTES T01-A INSTALLATION INSTRUCTIONS 现代型分体座便器 CONTEMPORARY TWO-PIECE TOILET K-17178T-S/K-17178T-SP

Technical Data. Sizes 2 12 Inch (DN50 DN300)

SSS Intrepid 16 FMS. Manual

Model 8730 INSTALLATION, OPERATION & MAINTENANCE INSTRUCTIONS. Outdoor Shower and Eyewash System General Area Classification & Class I Division 2

Installation S HL2X2 High Capacity Manifold System. Table of Contents Rev. B; ECN Bradley Page 1 of 8 11/10/2014

Elite. User s Information Manual. Elite and Elite VWH* All Models

Niles Steel Tank Hot Water Generator Installation and Operation Manual

Patterson/AMT Inline Circulator Pump Refer to pump manual for General Operating and Safety Instructions.

Operator s Manual for Morse Hydra-Lift Drum Karrier

Serial No.: and Up OPERATING INSTRUCTIONS MODEL AR. STEAM GENERATORS CAUTIONS:

Catalog. Self-operated Regulators Volume 2 Temperature Regulators

Water Softener Installation Guide Effective for all Softeners from our Range

SERVICE MANUAL (v1) UL / ULC. WET CHEMICAL HAND PORTABLE RESTAURANT KITCHEN FIRE EXTINGUISHERS Model: SF-6LK / WBDL-6LK

REIMERS ELECTRA STEAM, INC. INSTRUCTION MANUAL JG & JJ MODELS

20 TON AIR/MANUAL SHOP PRESS

INSTRUCTION MANUAL. Keep this manual in a safe place for future reference TEMPERATURE CONTROL STEAM TRAP LEX3N-TZ LEX3N-TZ.

User s Information Manual

Instruction Manual - Anti-Siphon Ejector Chlorine & Sulfur Dioxide 500 PPD (10 kg/h) Maximum Capacity

Model A Pipe Line Strainer 3, 4, 6, 8 & 10 Inch (DN80, DN100, DN150, DN200 & DN250) 175 psi (12,1 bar) General Description.

OPERATING MANUAL MODEL AIR 1500TM AIR DRYER

8707T Includes seat. 8745T Includes Bowl

FLUID POWER ENERGY, INC. W229 N591 Foster Court Waukesha, WI THERMOSTATIC VALVES. Instruction and Application Guidelines

INSTALLATION INSTRUCTIONS CARE AND MAINTENANCE

UHIR Series. Horizontal or Vertical Mounting Industrial / Commercial Electric Unit Heater. Owner s Manual

Model: 1200 Model: 1200-G Model: 1200-N Float-Controlled Condensate Trap, PN 40

Transcription:

Installation, Operation & Maintenance Instructions 313 OVERFLOW TRAP TALE OF CONTENTS Overview... Cover General Information... Cover Installation... 4 Operation... 4 Maintenance... 4 Float all Level Test Procedure... 5 Float all Level Adjustment Procedure... 6 Information Present on 313's... 7 Overflow Trap Specifications... 9 Parts Kits / Overhaul...9 & 10 Drawings...11 PRODUCT Overview This document covers the installation, operation and maintenance of 313 Overflow Traps presented in the Level Controls and Accessories, Product Specification. General Information The instructions given herein cover generally the operation and maintenance of subject equipment. Should any questions arise which may not be answered specifically by these instructions, they should be referred to Warren Controls Inc. for further detailed information and technical assistance. This manual cannot possibly cover every situation connected with the operation, adjustment, inspection, test, overhaul and maintenance of the equipment furnished. Every effort is made to prepare the text of this manual so that engineering and design data is transformed into the most easily understood wording. Warren Controls Inc., in furnishing this equipment and this manual, must presume that the operation and maintenance personnel assigned thereto have sufficient technical knowledge and experience to apply sound safety and operational practices which may not be covered herein. In applications where Warren Controls Inc. furnished equipment is to be integrated with a process or other machinery, these instructions should be thoroughly reviewed to determine the proper integration of the equipment into the overall plant operational procedures. Warren Controls does not assume responsibility for the selection, use, or maintenance of any product. Responsibility for proper selection, use, and maintenance of any Warren Controls product remains solely with the purchaser and end-user

! WARNING!! Check overflow trap for any damage due to improper storage or transportation. Immediately notify your sales organization of any damaged goods upon receipt. Do not attempt to move or disturb the overflow trap further so photos may be taken. If the shipping container is noticeably damaged refuse receipt, as the shipping company should be held liable until a shipping representative is available to take photos. 2 2600 Emrick lvd ethlehem, PA 18020 USA 800-922-0085 www.warrencontrols.com

Warren Controls Level Controls at Work... The following is a typical example of a tank filling/deaerator application using properly sized, selected, and maintained Warren Controls Level Controls. Demand for water reduces the liquid level in the tank. The [A] 377 Float Cage opens the [] 322L or 326L Lever Valve to supply intake water to the tank. When the water reaches the desired level the float cage closes the lever valve to accurately maintain the liquid at the desired level. Deaerators, tanks with steam blankets, produce additional liquid as the steam condenses. The [C] 313 Overflow Trap traps and relieves this condensate through its internal pilot without the steam blanket escaping. Overflow can occur if the water entering the tank exceeds its capacity. The 313 Overflow Trap relieves the overflow through its internal single seated main stage valve. Falling liquid levels and condensing steam can cause a vacuum that can damage the tank. The [D] 200 Vacuum reaker opens to admit outside air to relieve the vacuum in the tank. Warren Controls Level Controls are also used on boiler make-up water tanks and many other storage tank applications. Level COntrols - IOM 313 313_IOM_RevAb_1112 3

Installation Type 313 Overflow Trap To determine which 313 Overflow Trap you have locate the part number on the factory serial number label (See Information Present on 313 Overflow Trap section for location of important information on overflow traps). Then see 313 Overflow Trap Specifications section to determine the performance and physical characteristics of the overflow trap). The overflow trap must be installed in vertical pipe with its inlet up as shown on the installation orientation label (See Information Present on 313 Overflow Trap section for location of important information on overflow traps). Eliminate vibration in piping. 313 Overflow Traps are not suitable in installations where vibration exists. efore installing, be sure the 313 Overflow Trap and piping are clean inside and free of scale, chips, welding spatter, and foreign material. Thoroughly blow out or flush pipe lines. Do not obscure factory serial number label or installation orientation label with paint. Pipe plug must be installed in float chamber during operation. Operation Type 313 Overflow Trap Deaerators, tanks with steam blankets, produce condensate as the steam condenses. The 313 Overflow Trap traps and relieves this condensate through its internal pilot while keeping the steam blanket from escaping. Overflow can occur if the water entering the tank exceeds its capacity. The 313 Overflow Trap relieves the overflow through its internal single seated main stage valve. uoyancy of the overflow trap s internal float ball provides force to actuate the internal pilot operated single seated valve assembly to relieve condensate and overflow to drain. It is normal for condensate to intermittently flash to steam as it is relieved to the drain. Steam from the steam blanket however should not be continuously exiting the overflow trap to the drain. Maintenance Type 313 Overflow Trap 313 Overflow Traps for the most part are maintenance free when sized and chosen properly for the application. Maintain the fluid pressure, pressure drop, and temperature within the limits of the overflow trap (See Information Present on 313 Overflow Trap section for location of important information on overflow trap and 313 Overflow Trap Specifications section to determine the performance and physical characteristics of the overflow trap). The inlet and outlet of the overflow trap must be kept unblocked. The internal pilot operated single seated valve assembly must be kept free of debris, deposits, and dirt. The internal pilot operated single seated valve assembly must move freely. The float ball must not be come filled with water. The float lever must be straight. Factory set-up of the overflow trap is shown on drawing 03130611101. The water level inside the float chamber must cover the windows in the valve body in order for the main stage to open. Perform Float all Level Test during scheduled maintenance periods. Float ball level must be correct for water to be at correct level in the float chamber. A set-up fixture may also be fabricated as shown on drawing 03130614111 to test and set the float ball level. Pipe plug must be installed in float chamber during operation. 4 2600 Emrick lvd ethlehem, PA 18020 USA 800-922-0085 www.warrencontrols.com

Float all Level Test Procedure: 1) Remove line pressure and isolate overflow trap. (It is recommended that you have an Inspection Kit on hand before beginning the procedure.) 2) Remove nuts and bolts from end cover. 3) Remove end cover from float chamber. 4) Remove end cover gasket. 5) Remove capscrews holding valve body to float chamber. 6) Remove internal valve assembly with float ball from float chamber. 7) Install internal valve assembly with float ball in float chamber with float ball extending out of the open end of the float chamber. Use clamps to secure internal valve assembly with float ball to float chamber. 8) With piston disc seated in valve body and pilot assembly seated on piston disc, measure vertical distance from bottom of float ball to bottom of valve body. 9) Compare measurement to values in Float all Level Table. If measurement is within the range of values in table complete remaining steps. If measurement is not within range of values in table perform Steps 8 thru 20 of Float all Level Adjustment Procedure, found on page 6. 10) Remove clamps and remove internal valve assembly with float ball from float chamber. 11) Remove valve body gasket. 12) Clean gasket surfaces of end cover, valve body, and float chamber. 13) Install new valve body gasket in float chamber. 14) Install internal valve assembly with float ball in float chamber. Watch orientation. 15) Install capscrews in valve body and tighten to secure valve body to float chamber. 16) Install new end cover gasket on float chamber. 17) Install end cover on float chamber. 18) Install nuts and bolts in and cover and tighten to secure end cover to float chamber. OVERFLOW TRAP SIZE FLOAT ALL LEVEL 1 bottom OF FLOAT ALL between 0.0 INCHES AOVE AND 0.168 INCHES AOVE bottom OF VALVE ODY 1-1/2, & 2 bottom OF FLOAT ALL between 0.340 INCHES ELOW AND 0.112 INCHES ELOW bottom OF VALVE ODY 3 bottom OF FLOAT ALL between 0.050 INCHES ELOW AND 0.118 INCHES AOVE bottom OF VALVE ODY 4 bottom OF FLOAT ALL between 0.080 INCHES ELOW AND 0.102 INCHES AOVE bottom OF VALVE ODY 6 bottom OF FLOAT ALL between 0.590 INCHES AOVE AND 0.720 INCHES AOVE bottom OF VALVE ODY Level COntrols - IOM 313 313_IOM_RevAb_1112 5

Float all Level Adjustment Procedure: 1) Remove line pressure and isolate overflow trap. (It is recommended that you have an Inspection Kit on hand before beginning the procedure.) 2) Remove nuts and bolts from end cover. 3) Remove end cover from float chamber. 4) Remove end cover gasket. 5) Remove capscrews holding valve body to float chamber. 6) Remove internal valve assembly with float ball from float chamber. 7) Install internal valve assembly with float ball in float chamber with float ball extending out of the open end of the float chamber. Use clamps to secure internal valve assembly with float ball to float chamber. 8) Remove cotter pin and clevis pin from lever bracket. Separate float lever from lever bracket. 9) Loosen jamnut on lever bracket. 10) Adjust engagement of lever bracket with lever bracket base so float ball level is within range of values shown in Float all Level Table with piston disc seated in valve body and pilot assembly seated on piston disc, when clevis pin, cotter pin, and float lever are reinstalled in lever bracket. 11) Tighten jamnut to secure lever bracket to lever bracket base. Float lever must not bind in lever bracket. 12) Remove clamps and remove internal valve assembly with float ball from float chamber. 13) Remove valve body gasket. 14) Clean gasket surfaces of end cover, valve body, and float chamber. 15) Install new valve body gasket in float chamber. 16) Install internal valve assembly with float ball in float chamber. Watch orientation. 17) Install capscrews in valve body and tighten to secure valve body to float chamber. 18) Install new end cover gasket on float chamber. 19) Install end cover on float chamber. 20) Install nuts and bolts in and cover and tighten to secure end cover to float chamber. Overhaul Rebuilding of the overflow trap should not be necessary under normal operating conditions. Should the overflow trap become worn or defective, parts kits are available. See Parts/ Overhaul. 6 2600 Emrick lvd ethlehem, PA 18020 USA 800-922-0085 www.warrencontrols.com

Information Present on 313 Overflow Trap There is information present on each overflow trap ranging in importance from the part number and serial number to numbers stamped on the tank. This information is important for identifying the overflow trap, installing it correctly, and obtaining parts. An example of the current factory serial number label used on 313 overflow traps is shown here. The accompanying table identifies the information present and where to find it on the overflow trap. There may also be other numbers and marks present that do not provide useful information. Customer specific tagging may also present. The labels or plates used, and information present, on Warren Controls other product lines or older overflow traps may be different, contact the factory for details. Factory Serial Number Label Installation Orientation Label INFORMATION PRESENT ON 313 OVERFLOW TRAPS Part Number & Serial Number Information Symbol(s) Location Notes Part number P/N On end cover * On Factory Serial Number Label attached to end cover. Serial Number SERIAL NO. On end cover and valve cover Installation Orientation Information Symbol(s) Location Notes * On Factory Serial Number Label attached to end cover. * Sales order number only stamped on valve cover.* * Number stamped using approximately 1/8 inch tall characters Top of overflow trap TOP On tank On Installation Orientation Label attached to side of tank. Up direction UP On tank On Installation Orientation Label attached to side of tank. Level COntrols - IOM 313 313_IOM_RevAb_1112 7

313 Overflow Trap Specifications 313 Part Number Description Size End Connection Part Number STEEL ODY WITH RONZE TRIM AND 316 ST. STL. FLOAT ALL CONDENSATE CAPACITIES: Pressure Pounds / Hour Flashing Condensate Drop (PSI) Valve Size (IN) 1 NPT 031306XXX001 1-1/2 NPT 031308XXX001 2 NPT 031309XXX001 3 150FLG 031311XXX001 4 150FLG 031313XXX001 6 150FLG 031315XXX001 1 1-1/2 2 3 4 6 1 4,500 10,800 20,400 35,500 62,000 132,000 2 6,400 15,400 28,700 50,000 88,000 187,000 4 9,000 21,600 40,400 70,500 123,500 262,000 5 10,000 24,000 45,000 78,500 138,000 293,000 7 11,870 28,500 53,300 93,000 163,000 346,000 10 14,200 34,100 63,700 111,200 196,000 415,000 12 15,600 37,400 69,900 122,000 214,500 455,000 15 17,400 41,800 78,200 136,500 239,000 500,800 Serial number label located here APPLICATION: Deaerators, tanks with steam blankets, produce additional liquid as the steam condenses. The 313 Overflow Trap traps and relieves this condensate through its internal pilot without the steam blanket escaping. uoyancy of its float ball provides force to actuate internal pilot operated single seat valve assembly to relieve condensate and overflow to drain. The overflow trap should be installed in an upright position. FEATURES: Steel chamber, brass/bronze internal valve, 316 stainless steel float ball. Sizes 1 through 2 with NPT connections, 3 through 6 with 150FLG Large end cover provides easy access to internal valve assembly. RATINGS: System operating pressures to 50 PSIG Pressure drops to 15 PSI Temperatures to 250F Nominal leakage rate 0.1% of rated capacity WEIGHTS: Valve Size (IN) 1 1-1/2 2 3 4 6 Sales order (serial) number label stamped here 3 313 rass/bronze internal valve assembly with 316 stainless steel float ball and float arm shown separately Weight (lb) 53 95 95 111 173 285 For dimensions see drawing 03130611101. 8 2600 Emrick lvd ethlehem, PA 18020 USA 800-922-0085 www.warrencontrols.com

313 Overflow Trap Parts/ Overhaul (Refer to Drawing 03130611101) Damaged or worn parts can decrease performance and shorten the life of the overflow trap. A damaged float ball can result in the inadequate removal of condensate and overflow. A damaged or worn end cover gasket or inner valve body gasket can cause external leakage resulting in damage to surrounding equipment and the loss of the steam blanket from the tank. A damaged float lever can result in the inadequate removal of condensate and overflow or the loss of the steam blanket from the tank. A damaged or worn pilot subassembly can result in the inadequate removal of condensate and overflow or the loss of the steam blanket from the tank. A damaged or worn piston can result in the inadequate removal of condensate and overflow or the loss of the steam blanket from the tank and can also cause damage to the valve body. A damaged or worn inner valve body can result in the inadequate removal of condensate and overflow or the loss of the steam blanket from the tank and can also cause damage to the piston disc. A damaged or worn stem guide can result in the inadequate removal of condensate and overflow or the loss of the steam blanket from the tank and can also cause damage to the pilot assembly. A damaged or worn clevis, clevis pin, or fulcrum link can result in the inadequate removal of condensate and overflow or the loss of the steam blanket from the tank. Three different parts kits are available. The inspection kit allows for the overflow trap to opened so its internal parts may be inspected. The float ball kit allows for the float ball to be replaced. The internal vba kit allows for the entire internal valve body assembly, minus the float ball, to be replaced. The internal vba kit is preset at the factory to provide the correct water level in the float chamber. Individual parts are also available. Please provide serial number to get the correct kit or individual part numbers. Level COntrols - IOM 313 313_IOM_RevAb_1112 9

313 OVERFLOW TRAP PARTS KITS (Provide overflow trap serial number to get kit part numbers) Three different parts kits are available. The inspection kit allows for the overflow trap to opened so its internal parts may be inspected. The float ball kit allows for the float ball to be replaced. The internal vba kit allows for the entire internal valve body assembly, minus the float ball, to be replaced. The internal vba kit is preset at the factory to provide the correct water level in the float chamber. 313 INSPECTION KIT - SEE DWG 03130611101 ITEM QTY DESCRIPTION ITEM QTY DESCRIPTION 19 1 INNER VALVE ODY GASKET 23 1 END COVER GASKET 313 FLOAT ALL KIT - SEE DWG 03130611101 ITEM QTY DESCRIPTION ITEM QTY DESCRIPTION 4 1 FLOAT ALL 23 1 END COVER GASKET 19 1 INNER VALVE ODY GASKET 313 INTERNAL VA KIT - SEE DWG 03130611101 ITEM QTY DESCRIPTION ITEM QTY DESCRIPTION 1 2 CAPSCREW 12 1 JAMNUT 2 A / R WASHER 13 1 LEVER RACKET ASE 3 A / R CAPSCREW 14 1 INNER VALVE ODY COVER 5 1 FLOAT LEVER 15 1 INNER VALVE ODY 6 3 CLEVIS PIN 16 1 PILOT SUASSEMLY 7 3 COTTER PIN 17 1 STEM GUIDE 8 1 LEVER RACKET 18 3 CAPSCREW 9 1 FULCRUM LINK 19 1 INNER VALVE ODY GASKET 10 1 CLEVIS 20 1 PISTON 11 1 JAMNUT 23 1 END COVER GASKET 10 2600 Emrick lvd ethlehem, PA 18020 USA 800-922-0085 www.warrencontrols.com

Drawing 03130611101-1 Level COntrols - IOM 313 313_IOM_RevAb_1112 11

Drawing 03130611101-2 12 2600 Emrick lvd ethlehem, PA 18020 USA 800-922-0085 www.warrencontrols.com

Drawing 03130611101-3 Level COntrols - IOM 313 313_IOM_RevAb_1112 13

Drawing 03130614111 14 2600 Emrick lvd ethlehem, PA 18020 USA 800-922-0085 www.warrencontrols.com

NOTES Level COntrols - IOM 313 313_IOM_RevAb_1112 15

Level COntrols - IOM 313 313_IOM_RevAb_1112