V-10 AIR DRYER Installation and Operation Manual

Similar documents
V LPM Desiccant Air Dryer Installation and Operation Manual

VMUS-4 Ozone Generator

HTU-500 Ozone Generator

NT-40 Ozone Interceptor Owner s Manual

451 Black Forest Road Hull, IA Ph: (712) Fax: (712) TS g/hr Turnkey Ozone Generation System

TG-10 Wall Mount Installation and Operation Manual. High Output Ozone Generator

FOR THE RECORD. You should record the model and serial numbers, which can be found on the back of the unit, for future reference.

DR Series. Installation & Operations Manual. Model: DR-10 HIGH OUTPUT SHOCK TREATMENT OZONE GENERATOR

Thermo Scientific Model 1160 Principle of Operation

Using the Model 1500 Portable Chilled Mirror Hygrometer

ariazone 601HD Refrigerant Recovery & Recycling Unit User's manual

Odour Control - Water Purification Air Sterilisation MAINTENANCE INSTALLATION INFORMATION.

A2Z Ozone, Inc. PRODUCT MANUAL

IMPORTANT SAFETY INSTRUCTIONS EC-AG1-25 EC-AG1, EC-AG2 SAVE THESE INSTRUCTIONS.

Ariazone 601HD Refrigerant Recovery&Recycling unit

TG-Series. Installation & Operations Manual. Model: TG-75, TG-150, TG-300, TG-450, TG-600. Water Cooled Ozone Generator

MDX. Non-Cycling Refrigerated Compressed Air Dryers with zero-loss Intellidrain. Operation & Maintenance Manual MODELS MDX

TS-SERIES. Installation & Operations Manual. Model: TS-10, TS-20 COMPACT TURNKEY OZONE GENERATOR

Ozone Generator Systems

SR42G/52G Series Gas Fryers

Catalog 9CW-SD-9 Manual Desiccant Dryers Models X0, X0, X0 and X5 Wilkerson's Manual Desiccant Dryers offer the most cost effective method to remove m

1, 2, & 4. Corona Discharge Ozone Generators INSTALLATION & OPERATION MANUAL. DEL Ozone SAN LUIS OBISPO, CA USA Fax:

POD Silo Dehumidifier Series. with Logo! TM PLC POD-150 DOCUMENT: POD IM 14 DEC NOVATEC, Inc All Rights Reserved

SERVICING PROCEDURE R-410A LEAK TEST EVACUATION CHARGING. Bard Manufacturing Company, Inc. Bryan, Ohio Manual Page 1 of 11

Owner s Manual Refrigerated Compressed Air Dryers Model F-100

MDX. Non-Cycling Refrigerated Compressed Air Dryers with zero-loss Intellidrain Drain Trap. Operation & Maintenance Manual MDX MODELS 18 THRU 250

Next Generation Corona Discharge Installation & Operation Manual

User s Information Manual

SYNRAD Technical Bulletin # 0015d

Oil-Sealed Rotary Vane Pumps

Fig. 1 - Unit PGD4, PGS4, WPG4

Important Safety Instructions

RK-03 Hydrogen Detector Operator s Manual

Instructions for Model E782 Betman Cleaning System (Cleaner/Rinser/Rinser/Dryer)

Fume Hood Safety TYPES OF FUME HOODS

USER'S MANUAL PGE Single Package Rooftop

READ AND FOLLOW ALL INSTRUCTIONS SAVE THESE INSTRUCTIONS

OPERATING INSTRUCTIONS

Compressed Air Dryers

The Complete Guide to Gas Sample Drying for Your Analyzer or Process

Adsorption Air Dryers

Owner s Information Manual

Refrigeration air dryer

User's Infomation Manual

AC 1 AIR CONDITIONING SYSTEM

Professional Series. Chemical Feed System Model # US Patent No. 6,752,930 B2

Motor Vehicle Air Conditioning (MVAC) System operation and the refrigerant cycle

Truck Edition V-220 / V-320 Series Single Temperature Systems TK IM (Rev. 0, 06/17)

PZ2 Series Manual. PROZONE INTERNATIONAL, Inc. Ozone Water Purification Systems. INSTALLATION GUIDE and OPERATION MANUAL. Prozone PZ2 Series

User s Information Manual

OWNER S MANUAL. Vintage Signature Series models: AC750, AC1050, AC1100, AC1250, AC1500, AC1750. Proudly Made in the USA.

READ AND FOLLOW ALL INSTRUCTIONS SAVE THESE INSTRUCTIONS

Vacuum-ultraviolet Ozone Systems. Installation & Operation Manual. Model OZ-SPA

IQ/OQ Protocol Installation Qualification/ Operation Qualification

"ER" Series Electric Humidifier

HEATING AND AIR CONDITIONING

HTD. High Temperature Non-Cycling Refrigerated Compressed Air Dryers. Operation & Maintenance Manual. MODELS HTD 21 thru HTD 100

user s information manual

HEATLESS DESICCANT AIR DRYER INSTRUCTION & MAINTENANCE MANUAL

MAINTENANCE MADE EASY

The Technology of Modern Filtration KRAD. Compressed Air Dryer with integrated compressed air filters

Digital Refrigerant System Analyzer. MAXMIN Psi kpa Bar MPa C F R TIME P T UNITS

ML180UH SERIES GAS FURNACE WARNING WARNING

Problem Cause Remedial action. Gauge glass There was excess chemical dosage The normal ph recommended was 9.5 to See photo 3 & 4.

Packaged Heat Pumps. Owner s Guide to Operating and Maintaining Your Heat Pump

EXHAUST PURGE DESICCANT AIR DRYER INSTRUCTION & MAINTENANCE MANUAL MODEL RE-231 THROUGH RE-252

Vehicle Level Heating and Air Conditioning Description and Operation A/C System - Manual. A/C System - Manual

Safe Operation Manual. Honeywell IQ Force Gas Detector

Using the DewMaster Deluxe Dew Point/ Humidity Hygrometer

Owner s Manual Refrigerated Compressed Air Dryers Models F-3528, F-3529, F-3530, F-3531 & F-3532

USER'S INFORMATION MANUAL FOR THE OPERATION AND MAINTENANCE OF YOUR NEW GAS-FIRED FURNACE

Owner's Guide to Operating and Maintaining Your Gas/Electric Unit

Owner s Guide Installation & Operation

CAMAIR THE LEADER IN DRY AIR TECHNOLOGY

Ozone + UV Sanitation

OPERATION & MAINTENANCE MANUAL TX600

OZONE SYSTEM FOR IN-GROUND POOLS New and Existing

14. The center port of the manifold is used for evacuation, charging and refrigerant recovery.

MST, INC. MODEL 2002 CARBON MONOXIDE MONITOR OWNER S MANUAL

SECTION AIR COMPRESSORS AND ACCESSORIES

Ozone-Pro Water Treatment System

EcoMaster - Residential Pools up to 40,000 Gallons

Using the MiniRAE 2000 & ppbrae PID

GASS Module. User Manual. Gas Analysis Sampling System PERMA PURE

60 SCFM Eliminex & Eliminex Combo Type of contamination: water and dirt (& oil for combo) Eliminex Eliminex Combo Food Grade Separator/Coalescer Speci

EcoMaster - Residential Pools up to 40,000 Gallons

Field Inspection: MART Parts Washer

Condensing Unit Installation and Operating Instructions

120D, 150D, 190D, 240D, 370B. How to Order 220V 240V 400V 440V. Note 1) Select one applicable voltage. Voltage. Voltage. Symbol. Model 370B 220V 240V

DRI-AIR INDUSTRIES, INC. ARID-X10C FLOOR MOUNT DRYER OPERATING MANUAL

Air Preparation System

National Comfort Products 539 Dunksferry Road Bensalem, PA (215) Fax: (215)

OPERATING INSTRUCTIONS MANUAL (Please retain for future reference) F-400T DUAL FUEL CONSTRUCTION HEATER

USER S INFORMATION MANUAL

Fig. 1 - Unit PHD4 and WPH4

1 TECHNICAL CHANGES. MUZ-A09NA MUZ-A09NA - 1 MUZ-A09NA - U1 MUZ-A09NA - U2 1. Refrigerant system diagram has been changed.

CONTENTS CONSIDERATIONS. General Plumbing Component Connection ILLUSTRATION. Control System CONFIGURATION. Voltage Verification CONNECTION

Vertical Dryer Owner s Manual

The specifications in this document are subject to change without notice. DFD - DH Series. Desiccant Flexible Dryer & Drying Hopper Systems

ZERO AIR GENERATOR MODEL 7000 INSTRUCTION MANUAL

Transcription:

451 Black Forest Road Hull, IA 51239 Ph: (712) 439-6880 Fax: (712) 439-6733 www.ozonesolutions.com V-10 AIR DRYER Installation and Operation Manual

A. INSTALLATION CONCERNS. A.1. A.2. A.3. A.4. A.5. A.6. Ozone is a very strong oxidant. Only ozone resistant materials can be used in contact with ozone gas. A Balance Barometer, or WT-100 water trap, must be used with every installation, together with the check valve inside the MAZZEI injector. Two or more check valves are not sufficient. If the first one leaks, it will not provide the necessary backpressure needed to close the next one. Air dryers release moisture into the ozone room. Tiny amounts of ozone are generated around the high voltage terminals. Both will accumulate over time and cause the equipment to fail. Proper ventilation is required. The air for the ozone room must be free of dust, oil, acid and other volatile vapors. All these elements shorten the life of high voltage circuits and the airdrying desiccant. The air dryer requires uninterrupted power. If line power is disrupted, and restored in about 2-20 minutes, there is about 20% chance that steam may enter the air supply. The equipment must be protected from splashing water, rain, sun, mist, and excessive humidity. A maximum dew point of 55 deg F is allowable for the V-10. See the following chart for information on this. Rev - 02/12 Page 2

B. INSTALLATION. B.1. B.2. B.4. B.5. B.6. B.7. Mount the ozone generator and the air dryer side by side on a suitable wall. With soft PVC clear tube 1/4" I.D. connect the air dryer with the AIR IN terminal at the ozone generator. With the ¼ ID Teflon tubing connect the lowest terminal at the Balance Barometer via stainless steel ball valve to the injector. Secure all connections with clamps and keep the valve open for now. With the same Teflon tubing connect the OZONE outlet at the ozone generator with the upper s.s. fitting at the Balance Barometer. Fill water to the Balance Barometer until the lower (open) section is almost full. Plug the ozone generator and the air dryer into a power outlet and keep the power switch on the ozone generator OFF for now. C. FIRST START UP. C.1. C.2. C.3. C.4. Start the pump and observe the water level inside the Balance Barometer. If it rises to quickly and over the top, reduce the flow by the s. s. valve until the water level stabilizes about 10 cm (4") inches below the suction port. Check the flowmeter on the Ozone Generator. The flow should be ~4-6 LPM on the scale. If the flow is higher, reduce it with the s.s. valve. Keep the flow until the blue crystal indicator is blue. If the air dryer was in storage for a long time, it may take up to six hours to recover. It helps to power the air dryer overnight the day before installation. When the crystals are blue and flow no higher than 12 LPM, you can turn ON the ozone generator. D. OPERATION. The system works automatically. To stop the system, stop the pump. Do not interrupt power to the air dryer, otherwise the air drying cycle may be disrupted. E. MAINTENANCE. The Ozone Systems are designed to require minimal maintenance. THERE IS A DANGEROUS HIGH VOLTAGE INSIDE! DO NOT OPEN THE UNITS; THERE ARE NO SERVICEABLE PARTS INSIDE. DO NOT REPLACE FUSES; they do not fail without good reason. Only trained and qualified personnel are allowed to repair the equipment. The following list of procedures should be performed: Rev - 02/12 Page 3

DAILY: E.1. E.2. The fans must be running and the airflow unobstructed. If the FUSE light is lit, call for service. The moisture indicator should remain BLUE all time. If the color changes, the new color will indicate:. PURPLE - the dew point is above the allowable -40ºF. If a power failure took place within last five hours, continue to operate as is. The crystals will turn blue again in the next five hours. If not, contact your nearest dealer.. BLACK - the blue crystals are permanently damaged by an exposure to ozone. Check and restore the room ventilation, replace the indicator.. YELLOW - the blue crystals are permanently damaged by an exposure to oil vapors. In this case also the air-drying desiccant in main cylinders is damaged and must be replaced.. PINK/RED - the blue crystals are permanently damaged by an exposure to acid vapors in the air. The source of the problem must be identified and removed. Examples: A solid fuel burner near by, overcharged battery, E.3. E.4. E.5. Check the flowmeter for proper airflow. A low flow may indicate a problem with the pump, injector, or integrity of the tubing. Check the water level inside the clear pipe of the Balance Barometer and refill if water is too low. Check for signs of excessive dust around the cooling air intakes. Check the room filters and replace the inserts before dust may obstruct the flow. ANNUALLY: Disconnect the ozone generator from power and check for excessive dust. Failures caused by dust are not covered under the warranty. IN TWO YEARS: The air dryer may need new desiccant. This depends on the quality of air, also whether the dryer operates full time under full flow requirements. Under reduced flow and dust free ambient air the desiccant may last 2-5 years. Oily vapors will decrease life span of the desiccant dramatically. The desiccant is not covered under warranty. LATER: The cooling fans are rated for up to 100,000 hours of continues duty under ideal conditions. Excessive dust may decrease the life span considerably. Rev - 02/12 Page 4

Contact Information Ozone Solutions 451 Black Forest Road Hull, IA 51239 USA Ph: 712-439-6880 Fax: (712) 439-6733 www.ozonesolutions.com info@ozonesolutions.com Rev - 02/12 Page 5