M-LED for 4 Technical Ceilings Recessed Linear LED for 4 Technical Ceiling Systems

Similar documents
M100 LED Direct/Indirect

M60 LED Recessed Wet Location

Qty: L lm/12.6W K. DC3 Lutron 3-Wire. DMD eldoled DALI. DC2 5 Lutron 2-Wire

M100 My White LED Direct Tunable White

M36 My White LED Direct

RECESSED T-Bar & Drywall

RECESSED - WITH StepLens OPTION

Evolution EXWW RECESSED LINEAR WALL WASH LUMINAIRE

RECESSED Spec Guide. up to 111 lm/w performance

LUMINAIRE ID SIZE CENTER OPTICS SIDE OPTICS LIGHT SOURCE CRI LUMEN PACKAGES COLOR TEMP. VOLTAGE. LED - high performance LED 80-80CRI 90-90CRI

ZipTwo LED 707. Micro-profile interior direct lighting for open office, wall wash and wall graze applications. Spec Guide

SURFACE Spec Guide. up to 105 lm/w performance

LUX PENDANT DIRECT/INDIRECT

light ACL9 ANATOMY PERIMETER FOCUSED INSTALLATION SLEEK & STRONG

BAS SDL8' LED Strip Diffused Lens

Recessed LED Wall/Slot SAE 202

Catalog # Project. Comments. Prepared by. Warranty Five year warranty

SDL4 LED Strip Diffused Lens

Grüv Flare Regressed. Recessed Linear LED

Dimensions (111mm) 3 (76mm) (111mm) (48mm)

SOL CROSS SECTION. PENDANT Spec Guide. Page 2 of Rev. JUNE18-1

Dimensions (111mm) (111mm) 3 (76mm)

Grüv Flare Regressed. Recessed Linear LED

VESICA LINEAR SUSPENDED VES L

*REPRESENTS 3500K/80CRI 2 FT 4 FT 6 FT 8 FT 2 FT 4 FT 6 FT 8 FT *REPRESENTS 3500K/80CRI LINEAR

FULL BLEED APPLICATION SHOT RENDERING

BAS SFP22 Edge-lit LED Panel

2200TD-3000TD Dim to Warm* 2700T-6500T Tunable White* *Must be ordered with D05 or DS5 Driver options; excludes 2' and 3' lengths

SPECIFICATIONS HYLYTR. with DOUBLE SLOT OPTICS

LHBXD LED Linear High Bay

ACL 4 ANATOMY. COVER UP Partially diffuse dust cover enhances indirect lighting performance and preserves LED lifespan. 1.87

Etch 2' x 2' Recessed LED

CPPG ENERGY EFFICIENT CANOPY LIGHTS FOR PARKING AREAS

MEDLEY A. RoHS COMPLIANT INTERIOR - INTEGRAL POWER SUPPLY WHITE LIGHT & STATIC COLORS SHAPING THE EXPERIENCE OF LIGHT

NOVENTA NV3.5 Suspended, Surface, Wall, Recessed LED

DRD5S & SurfaceFrame Alt/EM Surface Mount LED Downlight

Project: Comments: Prepared By: Hardware Ordering Guide. Platform (see page 3 color chart) Wide Gamut. Tunable

ArcLine Recessed LED luminaire

Project: Comments: Prepared By: Hardware Ordering Guide. Platform (see page 3 color chart) Wide Gamut. Tunable

Metalux SWLED LED. Type. Catalog # Project. Date. Comments. Prepared by

lumenalpha downlight Specification Sheet

HBEAM 1.25 PRE-DESIGNED HB1.25 PRE-DESIGNED STRAIGHT SECTIONS (2FT - 8FT)

Alliance 4 - ALI4 LED 4 Linear High Bay

Recessed. DuaLED 2x , 2700, 3000, 3400, 3800, or 4400lm

Project: Comments: Prepared By: Control. Code Fixture & Trim D3 Wall Wash, Round. Platform & Control Wide Gamut, Tunable

LED FLAT PANEL EDGE LIT MLFP SERIES G2

RLN Recessed LED luminaire

Max 4 Flush Lens RECESSED

Type: Project : Luminaire characteristics: Source: Lumen maintenance: Optics: Material: Mounting: Electrical: Finish: Weight:

BAYMAX TM LED LINEAR HIGHBAY FIXTURE BLHT SERIES

DRD5S & SurfaceFrame Alt/EM 18" Linear Surface Mount LED Area Light

BeveLED Cylinder LBRP6 Surface

Claude Indirect Wall WALL

Fino Healthcare. Asymmetric Wall Mount Indirect LED

4 LED Recessed Adjustable. Energy efficient, stylish downlighting for residential and commercial applications

Linea 1.5. Linear Direct Wall Wash LED

Product Overview. Fixture Type. Performance Chart. Wattage. Electrical Data 23W System Watts Amps

Fino. Asymmetric Wall Mount Indirect LED

Capella 2. Project Name. Construction. Optical System. Product Applications. Housing and lens frame are constructed from heavy-duty low

3.75 Gyro Shift Multiples Single Head

CERRA 10 LED Design2Ship

Project Name. Date. Cat. Number. Type

Evoke Square Downlight

Truss Surface SURFACE

Evoke Square Downlight

Exterior LED Cylinder Lighting To The Next Level. FCC900 Series. delivering up to 5000 LUMENS! Specification Sheet

l i g h t A B S O R B H

Hornet HP. Round Glass Downlight

Fino Healthcare. Asymmetric Wall Mount Indirect LED

FPLHB - Fidelux Premier Linear Highbay

Exterior LED Cylinder Lighting To The Next Level. FCCSQ400 Series. delivering up to 3500 LUMENS! Specification Sheet

Performance Chart Electrical Data

Essentials Series 4.0

LIGHT CHANNEL.3 SURFACE MOUNT COMPLETE FIXTURE

Evoke Square Downlight

Project Name. Date. Cat. Number. Type

Catalog # Project. Comments. Prepared by. 23-3/4" [603mm] LAMP CONFIGURATIONS. 3-1/4" [83mm] X=2-7/16" [62mm] Y=2-1/2" [64mm] CEILING COMPATIBILITY

CIRRUS CEILING WALL GRAZER WITH REMOTE POWER

NOVA CEILING WALL GRAZER WITH REMOTE POWER

DIMMING 0-10V Continuous

Metalux 4WSL / 8WSL LED

Lumen Output (3500K) Lumen Efficiency (3500K)

Evoke 2.9" HP. 2.9" Square Downlight

Evoke 2.9" HP. 2.9" Round Lens Wall Wash

Addendum # 1 to Bid MEB Audiovisual Faculty Training Center Renovation

Classix 6" 6" Round Lens Wall Wash

Ordering Information: 4-ASI5-LED-WDM-35K-18K-4000L-MVOLT ASI5-LED

INSTRUCTION MANUAL IMPORTANT SAFEGUARDS. When using electrical equipment, basic safety precautions should always be followed, including the following:

LIGHT CHANNEL TRIM 1.6

Essenza. Round Downlights

Fahrenheit Recessed LED Downlight Fire and Sound-Rated New Construction 4, 5, 6 Aperture

MAR2 LED SERIES M A R 2 L E D. Linear LED Lighting for Hazardous Locations

800 TO 9000 LUMEN 8 LED RETRO-FIT HYPERBOLIC / PARABOLIC / WALLWASH LRT8 SERIES

Performance Chart Electrical Data

800 TO 9000 LUMEN 10 LED RETRO-FIT HYPERBOLIC / PARABOLIC LRT10 SERIES

LUXCOMFO TM LED Flood Light Datasheet

Evoke 2.9" HP. 2.9" Square Downlight

LED HIGH BAY LINEAR ECO SERIES

GL BAL GLEDAL 150W B L A Z E AISL E L IGHT SPECIFICATION SHE ET OPTICAL SPECS ELECTRICAL SPECS CERTIFICATIONS OTHER DETAILS DIMENSIONS BEAM ANGLES

Surface Mount Series Luminaires

Transcription:

Date: Customer: Project: Type: Qty: M-LED for 4 Technical Ceilings Order Code: LR4TZ - - - LW - TBZ - - - - - - LR4TZ Series LR4TZ M-LED for 4 Technical Ceiling Systems - Light Engine 1B45 1,2 713lm/10.8W 1B40 1,2 645lm/9.6W 1B35 1 567 lm/8.4w 1B30 1 485lm/7.0W 1B25 1 434lm/6.2W 1B20 1 328lm/4.6W 1 Values calculated from a 4 fixture @4000K and standard driver. For additional information please see page 2. 2 Not available with EMN or Lutron. CCT 27 2700K 30 3000K 35 3500K 40 4000K LW TBZ Shielding Mounting LW LED optimized white lens TBZ Technical Ceilings with suspension clips and 1 1/4-20 stud Nominal Fixture Length 02 2 ft. 04 4 ft. 05 5 ft. 06 6 ft. 08 8 ft. See pages 2 and 3 for additional details. XX Runs (over 8 )in nominal 1 steps to fit into 4 Technical Ceiling grid Finish WH White BK Black SV Silver SP Specify Premium Color Custom colors are available, Please consult factory Voltage 120 120 Volt 277 277 Volt UNV 120 thru 277V 50/60Hz capable 347 347V Driver DIM 3 0-10V (Linear) DC2 3,4 Lutron 2-Wire DM 3 eldoled SOLOdrive 0-10V (Linear) DC3 3 Lutron 3-Wire DML 3 eldoled SOLOdrive 0-10V (Logarithmic) DCE 3 Lutron Eco- System DMD 3 eldoled DALI (Logarithmic) DC5 SR 3,5 Lutron 5-Series Philips Xitanium SR DALI 3 See page 4 for full details 4 120V only 5 For use with E and P sensors only Fixture Options DL 6 Damp Location Rated FS 6 In-line Fuse SS 6 Separate Switching CCEA 7 CCEA approved 6 See page 5 for full details and restrictions 7 Not available with EMN option Sensor Options xe 8,9 Enlighted xp1 8,9 Philips Replace x with quantity xp2 8,9 Philips Occ/Vac xp3 8,9 Philips Occ/Vac/ xs1 8,10 Sensor Switch xs2 8,10 Sensor Switch Occ/Vac xs3 8,10 Sensor Switch Occ/Vac/ xsn nlight enabled 8 Minimum fixture length 2. See page 6 for full details and restrictions. 9 For use with SR driver only 10 For use with DIM driver only Emergency Options EC 11 Emergency Circuit Wiring EMN 12,13 EM battery pack (Non-IC-rated) EMR Remote Micro Inverter EM Integral EM battery pack 10 See page 5 for full details and restrictions 11 120 or 277 volt only 12 Not available on lengths under 4 5YEAR LED WARRANTY ARRA Compliant Page 1 of 7

4 (102mm) 4 5 /16 (110mm) 3 1 /16 (78mm) Construction: 3 7 /8 (99mm) Electrical/Performance: Luminaire Finish: Housing - Continuous, low copper 6063-T6 extruded aluminum profile with aluminum endcaps, available as Individual fixtures (up to 8 ) or Runs. Flange - Extruded aluminum flange fits both Armstrong TechZone 9/16 Slot Grid and 9/16 Tegular Grid ceiling systems. Geartray - Low copper 6063-T6 extruded aluminum profile. Shielding - Extruded, impact resistant acrylic lens, LED optimized white lens (LW). Mounting(s) - M-LED for 4 Technical ceilings works with Technical Ceiling Systems 9/16 Slot Grid and 9/16 Tegular Grid (see page 3 for details). Standard Luminaire lengths - All standard luminaires are supplied in nominal lengths to ensure full, even, illumination. Runs are available in nominal 1 increments starting at the nominal 8 fixture length, to fit Technical Ceiling Systems. ** Individual luminaires are not joinable in the field. Exact length luminaires - Individual luminaires and runs, are available in exact lengths to meet your project needs. Please consult factory with you requirements. ** Lens luminance may soften at the very ends of the straight sections for exact length luminaires. MLED Joiner(s) - Runs are supplied in multiple housings that are joined together in the field using the supplied LR4TZ Joiner System. This allows ease of installation and ensures a uniform appearance (see page 5 for detail). Weight: 2.4lb.. LED Light Engine - Brand-name mid-power LEDs create a high efficiency LED light engine able to provide a lumen maintenance of 96% at 25,000 hours and 93% at 60,000 hours per TM-21 report. LED Life - Calculated L70 greater than 398,000 hours and Reported L70 Greater than 60,000 hours @ 25 C per TM-21 Delivered Lumens - Due to LED manufacturer s tolerances the listed output has a ±5% tolerance. CCT - Available in 2700K, 3000K, 3500K and 4000K, tolerance within a 3-step MacAdam ellipse. CRI - Min. 90. All Drivers - High efficiency, constant current, soft start, Electronic Class 2 with a PFC>0.90. For more detailed information on the available drivers please see page 4. Sensors - Selux offers a variety of integral sensor options. For details and specifications, please refer to page 6. Thermal Performance: Ambient Operating Temperature - Luminaires suitable for Max. ambient temperature of 35 C (95 F) for all drivers, standard and optional. Min. ambient temperature of: -20 C (-4 F) for DIM, DM, DML, DMD, and SR drivers. 0 C (32 F) for the DC2, DC3 and DCE drivers. Powder Coat - All Selux luminaries are finished in high quality polyester powder coating in our Tiger Drylac certified facility and are tested in accordance with test specifications for coatings from ASTM and PCI. All products undergo a five stage intensive pretreatment process where product is thoroughly cleaned, phosphated, and sealed. Selux powder coated products provide excellent salt and humidity resistance as well as ultra violet resistance for color retention. Standard interior colors are White (WH), Black (BK), and Silver (SV). Selux premium colors (SP) are available, please specify from your Selux color selection guide. LM-79 testing is performed using white finish. Other finishes will impact light output. Warranty: 5 Year Limited LED Luminaire Warranty - Selux offers a 5 Year Limited Warranty to the original purchaser that the MLED series LED luminaire shall be free from defects in material and workmanship for up to five (5) years from date of shipment. This limited warranty covers the LED driver and LED light engine when installed according to Selux instructions and operated within the Ambient Temperature. For additional details and exclusions, see Selux Terms and Condition of Sale. Certifications and Compliance: NRTL - For Dry and Damp location (I.E. culus; ccsaus) ARRA Compliant RoHS Compliant IC-Rated * *EMN option is Non-IC-Rated Page 2 of 7

Technical Ceiling (TBZ) Mounting using Suspension Wire Technical Ceiling (TBZ) Mounting using 1/4-20 stud Technical Ceiling 9/16 Tegular mounting (TZB) (Wire Suspension or 1/4-20 Stud) Please Note: Luminaire supplied with both mountings shown above. They are shown above separately for clarification. Installer to select which mounting is required. 1. 9/16 Technical Ceiling Tegular grid (shown as ref.) 2. Support wire to structure (supplied and installed by others). 3. 1/4-20 Threaded rod to structure (supplied and installed by others). 4. 1/4-20 Coupler hardware (supplied and installed by others). 5. 1 1/4-20 Stud (by Selux). 6. Ø5/16 [Ø7mm] mounting hole. Nominal Length A Housing Length Technical Ceiling Systems Tegular (TBZ) and Flush (TBF) - Dimensions B End Suspensions BB Suspension Clips * * C (Ref.) Mid. Suspension D Feed Location E Grid Spacing Feet/Inch MM Feet/Inch MM Quantity Feet/Inch MM Feet/Inch MM Feet 02 (2 ft.)* 1' - 11 7/16" 595 0' - 1 5/8" 41 4x 1' - 8 3/16" 513 0' - 1 1/8" 28 2 Center to Center 04 (4 ft.)* 3' - 11 7/16" 1205 0' - 6 1/8" 156 6x 2' - 11 3/16" 894 0' - 2 1/8" 54 4 Center to Center 05 (5 ft.)* 4' - 11 7/16" 1510 0' - 6 1/8" 156 6x 3' - 11 3/16" 1199 0' - 2 1/8" 54 5 Center to Center 06 (6 ft.)* 5' - 11 7/16" 1815 0' - 6 1/8" 156 6x 4' - 11 3/16" 1504 0' - 2 1/8" 54 6 Center to Center 08 (8 ft.)* 7' - 11 7/16" 2424 0' - 6 1/8" 156 8x 6' - 11 3/16" 2113 0' - 2 1/8" 54 8 Center to Center *For other lengths, consult factory. **Dimension(s) rounded to the nearest 1/16 with a ± 1/16 (1mm) tolerance. Page 3 of 7

Drivers: 0-10V linear dimming (DIM) Luminaires supplied with drivers offering the capability of either normal switched operation of 0-10V dimming for linear dimming curve. Fixtures ship wired for dimming. For on/off functionality, simply cap the dimming leads. Minimum dimming level preset at factory to 1%. (Due to size constraints, 1 luminaires are supplied with a driver from a different manufacturer than 2 and above luminaires. For details, please consult factory). eldoled SOLOdrive 0-10V linear dimming (DM) Luminaires supplied with SOLOdrive 0-10V dimming driver for linear dimming curve. Minimum dimming level preset at factory to 1%. For dim to dark (down to 0.1%), please consult factory. eldoled SOLOdrive 0-10V logarithmic dimming (DML) Luminaires supplied with SOLOdrive 0-10V dimming driver for logarithmic dimming curve. Minimum dimming level preset at factory to 1%. For dim to dark (down to 0.1%), please consult factory. eldoled SOLOdrive DALI dimming (DMD) Luminaires supplied with SOLOdrive DALI dimming driver for logarithmic dimming curve. Minimum dimming level preset at factory to 1%. For dim to dark (down to 0.1%), please consult factory. * For control recommendations for eldoled drivers, please consult eldoled. LUTRON 2-wire dimming (DC2) Luminaires supplied with Hi-Lume 2-wire dimming driver programmed for Constant Current Reduction (CCR). For Pulse Width Modulation (PWM) dimming, please consult factory. Minimum dimming level down to 1%. LUTRON 3-wire dimming (DC3) Luminaires supplied with Hi-Lume 3-wire dimming driver programmed for Constant Current Reduction (CCR). For Pulse Width Modulation (PWM) dimming, please consult factory. Minimum dimming level down to 1%. LUTRON Ecosystem dimming (DCE) Luminaires supplied with Hi-Lume EcoSystem (4 wire, digital link) dimming driver programmed for Constant Current Reduction (CCR). For Pulse Width Modulation (PWM) dimming, please consult factory. Minimum dimming level down to 1%. * For control recommendations and system layout for Lutron drivers, please contact Lutron. Philips Xitanium Sensor Ready DALI dimming (SR) Luminaires supplied with Xitanium SR dimming driver programmed for Constant Current Reduction (CCR). Minimum dimming level down to 5%. For use with E and P sensors only. DIM, DM, DML, DMD, and SR drivers Driver Quantity 1 ft. 2 ft. 3 ft. 4 ft. 5 ft. 6 ft. 7 ft. 8 ft. 9 ft. 10 ft. 11 ft. 12 ft. RUN 1 1 1 1 1 1 2 2 2 2 3 3 Approximately 1 driver per 4 ft. DC2, DC3, & DCE drivers N/A 1 1 1 2 2 2 2 3 3 3 3 Consult Factory *For inrush and control current, please refer to the driver manufacturers spec sheets. Wiring Diagrams Sensor Wiring Diagrams 0-10V linear (DIM) 0-10V linear eldoled SOLOdrive (DM) 0-10V logarithmic eldoled SOLOdrive (DML) DALI eldoled SOLOdrive (DMD) Philips SR DALI (SR) DIM, DM, DML, DMD & SR DALI DALI standard ENLIGHTED OR PHILIPS SENSOR SR (+) SR (-) PHILIPS XR SENSOR SWITCH ELDO 0-10V (+) (-) 0-10V AUX (+) AUX (-) Page 4 of 7

Fuse (FS) - Fusing, luminaires supplied with a in-line fuse located on the hot wire for each feed. (supplied with an 8A slow burn fuse). Damp Location (DL) - Luminaires are suitable for use in damp location(s). Examples of such locations include protected areas under canopies, marquees, roofed porches, and similar locations where the fixture(s) are protected from direct contact with rain, snow, or excessive moisture (such as ocean spray). Interior locations include areas subject to moderate degrees of moisture, such as basements and certain barns and cold storage buildings. All solder points on LED boards are conformal coated. The phosphor layer of the LEDs is free of coating to avoid hazing. Separate Switching (SS) - Luminaires available with separately switched 4 (nominal) sections starting at 7 and up. Luminaire is intended to be wired to the same panel/breaker (not intended for Emergency use). - To specify this option, the number of separately switched sections and locations of these sections must be provided at time of order. *If the project requires different separate switching than outlined above please consult the factory. *For Separate Switching with sensors, please consult factory. *For Damp Location with sensors, please consult factory. EMN (Emergency Battery Pack)* - Emergency battery pack is available starting at the 4 nominal length and up in 2 nominal sections. The battery pack is housed in a box on the top of the luminaire and is fully accessible from below the ceiling. - For individual luminaires, the lit section will be located on the feed end of the fixture. If a different location is needed please consult the factory. EMN Model # Input Operation Time Lumen Output CCT Shielding IOTA ILB-2412 2.5W Max. 90 Min. *836 lm **4000K LW *Lumen output is fixed and the same for all light engines ** See page 6 for CCT multiplier - For Runs, please specify location of lit section (in 2 nominal sections). *Luminaires with EMN option are Non-IC-Rated * For EMN with sensors, please consult factory. Emergency Circuit (EC) - Luminaires with EC option compliant to UL 924 listed emergency luminaire. EC luminaires are intended to be wired to separate panels/breakers for emergency use. - For 1 to 6 nominal luminaires, the entire fixture is wired for operation on emergency circuit. - For 7 and up nominal luminaires, the first 4 nominal length is wired for operation by a separate EM circuit by default to meet the required Life Safety Code (NFPA 101). *If a different configuration is needed please consult the factory. *For EC with sensors, please consult factory. 2 (610mm) EMN pack 3 (76mm) Flex Whip - standard Joiner System - standard for Runs 90 Elbow on top of the housing (7/8" feed hole) 3/8" flexible metal conduit (6' long) 6" leads Straight fitting Page 5 of 7

Sensor Ordering Chart Quantity Sensor Settings * x Number of Sensors E Enlighted FS-D22 P Philips Easy Sense SNS102 S Sensor Switch MSD EZ 1 2 Occupancy/Vacancy 3 /Occupancy/Vacancy * Settings not available with Enlighted Enlighted FS-D22 (E) Occupancy/vacancy, daylight harvesting, plus the Internet of Things (IoT) data collection and reporting. For full details, please see FS-D22 spec sheet on the Enlighted website. Must be paired with Philips Xitanium SR driver (SR driver selection). Commissioning by Enlighted. *Please contact Enlighted for complete details prior to specifying. *Sensor can control up to 4 drivers. Please refer to driver quantity chart on page 7. Multiple sensors may be required for longer lengths. Philips EasySense SNS102 (P) Occupancy/vacancy and daylight harvesting. Sensor can be programmed on-site via NFC or IR using Android app only, by others. For full details, please see the SNS102 spec sheet on the Philips website. Must be paired with Philips Xitanium SR driver (SR driver selection). Wall dimming via wireless wall switch from Philips/Illumra (www.illumra.com/easysense). **Please contact Philips for complete details prior to specifying. *Sensor can control up to 10 drivers. Please refer to driver quantity chart on page 7. Multiple sensors may be required for longer lengths. Sensor Switch MSD EZ (S) Occupancy/vacancy and daylight harvesting. For full functionality and programming options, select settings option 3. If a different settings option is selected, other settings may be unavailable. For full details, please see MSD EZ spec sheets on the Sensor Switch website. Must be paired with eldoled 0-10V driver (DIM driver selection). Manual control of dimming not available with MSD EZ sensor. *Please contact Sensor Switch for complete details prior to specifying. *Sensor can control up to 30 drivers. Please refer to driver quantity chart on page 7. Multiple sensors may be required for longer lengths. Occupancy Vacancy Harvesting Driver Compatibility Enlighted FS-D22 (E) See Enlighted s website for full capabilities SR Philips EasySense SNS102 (P) SR Sensor Switch MSD EZ (S) DIM Factory Presets - Sensors come from the sensor manufacturer with factory presets for each of the settings in above chart. Please see sensor manufacturers spec sheets for details on presets and re-programming. Commissioning - Commissioning of sensors and installation by others. Contact sensor manufacturer for details and costs associated with commissioning the system prior to specification of sensors. Standard Sensor Placement - for other placement options, please consult factory. For functionality and limitations, please see sensor details above. Qty 1 Sensor - Beginning Qty 2 Sensor - Beginning and End (9 fixtures and longer) Lit Section* Fixture Length 3 (76mm) Qty 3+ Sensor - For spacing between sensors, please consult the sensor manufacturer. 3 1 /16 (78mm) Beginning of Run Lens Aluminum Sensor Plate -to be painted same as fixture unless specified otherwise Notes: 1. For spacing between sensors, please consult the sensor manufacturer. 2. Exact sensor placement and coverage will be defined by approved factory drawing. 3. Sections controlled by sensors may not be symmetrical - consult factory for layout. * Lit section will be the fixture length minus 3 for sensor plate. Page 6 of 7

Photometry LW Optics / 34W LED / 4000K CCT Link to photometry (IES & PDF files) 789 592 394 197 Catalog #: LR4TZ-1B35-40-LW-X-04-XX-UNV Report #: 11685024.01 Delievered Lumens: 2267 Input Watts: 33.5181W Efficacy: 68 Power Factor: 0.989 Total Harmonic Distortion: 10.5 CCT: 4000K CRI: 95.7 Max Candela: 788.8 @.5 from Vertical Spacing Criterion (0-180): 1.28 Spacing Criterion (90-270): 1.28 Spacing Criterion (Diagonal): 1.38 Maximum Candela = 788.8 Located At Horizontal Angle = 22.5, Vertical Angle =.5 # 1 - Vertical Plane Through Horizontal Angles (90-270) # 2 - Vertical Plane Through Horizontal Angles (0-180) 1 2 LR4TZ LED Direct Photometry Multiplier Table CCT Multiplier 4000K 3500K 3000K 2700K Light Engine Multiplier 1.000 0.972 0.963 0.931 Light Engine Lumens Wattages 1B45 1.258 1.285 1B40 1.137 1.140 1B35 1.000 1.000 1B30 0.855 0.838 1B25 0.766 0.740 1B20 0.578 0.552 CCT and CRI multipliers apply to the photometry, IES files, and values listed on page one (light engine). Light engine multiplier supplied for values listed on page one (light engine). Page 7 of 7