Inline mixed-flow fans with the air capacity up to 450 m 3 /h

Similar documents
Inline mixed-flow fans with the air capacity up to 1850 m 3 /h

Offices. Conference halls. Kindergartens Libraries. Restaurants. Schools. Sport halls. Shops

Series VENTS MPA...W. Supply units with the air capacity up to 6500 m 3 /h in the compact sound- and heat-insulated casing with water heater

for a considerable reduction of the supply air temperature which, in turn, reduces the air conditioning

VENTS КАМ. Series CHIMNEY CENTRIFUGAL FANS

Domestic fans. Circular duct fans 1. Rectangular duct fans 2. Roof fans 3. Axial fans 4. Smoke evacuation fans 5.

INLINE MIXED FLOW FANS IN SOUND INSULATED CASING VENTS TT SILENT M USER MANUAL

Series. Suspended air supply units with the air capacity up to 4100 m 3 /h in the sound- and heat-insulated casing with the water heater

CENTRIFUGAL FANS user's manual. model VENTS VK.

INLINE MIXED-FLOW FANS VENTS TT SERIES USER'S MANUAL.

Turbo. Service Instructions

РУКОВОДСТВО USER ПО MANUAL ЭКСПЛУАТАЦИИ CENTRIFUGAL INLINE FANS VKM / VKMZ / VC SERIES

WORLD VENTILATION LEADER SINGLE-ROOM AIR HANDLING UNITS WITH NEAT RECOVERY VENTILATION SYSTEMS

Series VENTS VUT R WH ЕС

Duct electric heater with temperature controller

SOUND-INSULATED FAN. Iso-B OPERATION MANUAL

Series VUT PW EC. wool internal heat and sound-insulating layer for VUT PE/PW 350, 600, 1000 units and 50 mm for VUT PE/PW 200, 3000 units.

panel filters with filtering class G4. Supply filter F7 can be supplied with the few models.

SOUND-INSULATED FAN. Iso-K OPERATION MANUAL. Iso-K_v.1(2)-EN.indd :20:59

INTELLIGENT AXIAL FAN user's manual

Duct electric heater with heating. capacity from 0.6 kw up to 2.4 kw and an integrated. temperature controller

Centrifugal inline fans

panel filters with filtering class G4. Supply filter F7 can be supplied with the few models.

USER S MANUAL. VKP Series INLINE FAN

Smart Smart IR. Service instruction SALES DATE MANUFACTURED ON (DATE): APPROVAL MARK SOLD. model (check applicable) is recognized as serviceable

Mini fans MiniVent M1/100

KOMFORT EC DB Suspended heat recovery air handling units

SINGLE-ROOM ENERGY RECOVERY VENTILATORS

Contents. How to choose Recovery Ventilation type?...3. How do HRV, ERV and TRV Systems work?...4. Types of installations...5. VUT 200 H mini...

The Straight Way K Sileo Series

66 on. Central ventilation system ZLS-DV EC according to DIN Central ventilation system ZLS EXTRACT AIR FIRE PROTECTION OUTSIDE AIR

INLINE CENTRIFUGAL FAN. Centro-M OPERATION MANUAL

Catalogue section. Contents Quick fan selection Quick selection of air handling units About us Ventilation in our life...

Fans for Life! CA-TD0708. The World s Leading Producer of Air Movement Products

USER S MANUAL. Heat Recovery Ventilator. Vents Brig HRV 200 Vents Brig HRV 300

MAXI CENTRALIZED VENTILATION WITH HEAT RECOVERY

KOMFORT EC S5B KOMFORT EC D5B KOMFORT EC S. Heat and Energy Recovery Ventilators

INLINE СENTRIFUGAL FAN BOX BOX-R OPERATION MANUAL

BATHROOM EXTRACT FANS SILENT-100 Series

SINGLE-ROOM REVERSIBLE UNIT WITH HEAT AND HUMIDITY RECOVERY VENTO V50-1 OPERATION MANUAL

CYLINDRICAL CASED AXIAL FLOW FANS. Cylindrical cased axial flow fans TCBB. Corrosion resistance. Impeller dynamically balanced.

OPERATION MANUAL CENTRIFUGAL INLINE FAN WITH ELECTRONICALLY COMMUTATED MOTOR VKM EC SERIES. F88EN-02.indd :07:11

RAPID RESPONSE. Quiet Operation. Powerful Performance. Header Box Exhaust Fan

AXIAL FAN User s manual. Quiet-dMEV 100 DC.

VENTS VUT R TN H ЕС VENTS VUT R TN EH ЕС

CONTENTS. Vitro Series Z Series LD Series MA Series X Series VKO 1 Series MAO 1(MAO 2) Series VN Series K Series Accessories Order code

Centrifugal extract and condensation control fans

Destratification Fan Units DRF-VK & DRF-VKM & DRF-OV

Installation manual Mini Comfort 50 S/L 07/ V EN

HEAT RECOVERY AIR HANDLING UNIT

SINGLE-ROOM HEAT AND ENERGY RECOVERY UNITS

USER S MANUAL. VCU/VCUN Series CENTRIFUGAL FAN IN SCROLL CASING

Turbo Inline Fan, White - Non Illuminated Art no.33500

USER MANUAL. Frigate HRV 120 SR Frigate ERV 120 SR. Heat (energy) recovery ventilation unit

Introduction to Fans. The Basics of Fan Principles and Terminology

Wind. Service instruction

USER'S MANUAL. Single-room reversible energy regeneration ventilator. TwinFresh R-50 TwinFresh RA-50 TwinFresh R-50-2 TwinFresh RA-50-2

White - Non Illuminated Art no White - Cool White LED Art no.32600

S ILENT Series INSTALL SILENCE, INSTALL QUALITY OF LIFE. The Quietest Extractors in the World in their Category 26,5

COMMERCIAL VENTILATION

USER S MANUAL. Centrifugal inline fan. VKMz 100 Q VKMz 100 VKMz 125 Q VKMz 125. VKMz 250 Q VKMz 250 VKMz 315 Q VKMz 315

more than just a fan supplier more than just a fan supplier Axair Fans UK Limited

FRESHBOX 100. Single-room heat recovery unit. Air flow up to 59 CFM Heat recovery efficiency up to 96 %

VMA-VMB NOVA AIR HEATERS. NoVa air heaters

Caution: The fans must not be used in bath or shower enclosures.

HRU SINGLE DWELLING HOUSES - ENERGY RECOVERY VENTILATION SYSTEMS WITH HEAT EXCHANGER AKOR BP HR Series

FRESHBOX 100. Single-room heat recovery unit. Air capacity up to 100 m³/h Heat recovery efficiency up to 96 %

Energy saving ventilation Air handling units (Catalogue no. 2) Industrial and commercial ventilation. (Catalogue no. 1)

Fresh air unit ALB. ALB it s simple and so easy! Air supplied through a heater and filter in a single unit.

GUIDELINES FOR A CORRECT VENTILATION

HEAT RECOVERY VENTILATOR

Aero. Service Instructions

dmev Unit Quietest dmev available. Discreet, tasteful styling. Single fan for use in all applications.

USER MANUAL. Air handling unit with heat recovery. VUT 300 EVK mini EC VUT 300 EV mini EC VUT 301 EVK mini EC VUT 301 EV mini EC

Midea VFD Centrifugal Chiller Technology

AXIAL FANS USER S MANUAL

SINGLE ROOM HEAT RECOVERY AIR HANDLING UNIT

USER S MANUAL. Heat (Energy) Recovery Ventilator. Vents Frigate HRV 120 S Vents Frigate ERV 120 S

Model with intellectual humidity control and extra motion sensor control

World-class small room fans. Premium design with highest energy efficiency.

Selecting the Correct Fan

Calm. Service Instructions

CENTRIFUGAL CEILING EXTRACT FAN

Domestic & Commercial Fans

KITCHEN EXTRACTORS K Series

HEAT RECOVERY AND ENERGY RECOVERY VENTILATORS

The Silent Range Pure Elegance & Tranquillity. The widest range of ultra quiet silent fans

CENTRIFUGAL FAN IN SCROLL CASING. Helix S-Vent OPERATION MANUAL

DanVex AD-550 Adsorption air dehumidifier. Operation manual

NKW. Heater series HEATERS

ENERGY SAVING VENTILATION GEO VENTS GEOTHERMAL SYSTEMS

HRU SINGLE DWELLING HOUSES - BALANCED AIRFLOW WITH HEAT EXCHANGER AKOR ST HR Series

SAX. Window & Wall Fans

(57.7) X. March 2006 PRODUCTS. ... the complete solution

HEAT RECOVERY AND HEAT AND HUMIDITY RECOVERY AIR HANDLING UNIT

DanVex AD-200 Adsorption air dehumidifier. Operation manual

USER S MANUAL VUT V(B) EC А14 VUE V(B) EC А14. Heat/heat and humidity recovery air handling unit

CI/SfB (57.7) 3rd Edition WINNER2011. Winners of the Energy Efficiency Initiative 2011 Award with our Lo-Carbon Continuous Ventilation Product Range.

100 FLUEBOOST

SPLASHPROOF AXIAL EXTRACT FANS USED TO EXTRACT AIR EITHER DIRECTLY TO THE OUTSIDE OR INTO DUCTING UP TO 4m LONG

Transcription:

FANS FOR ROUND DUCTS Series VENTS ТТ PRO Series VENTS ТТ perform required servicing. All the models may be equipped with a regulated timer with turn-off delay adjustable from 2 to 30 min. TT PRO design features: The inlet spigot is equipped with a collector to enable smooth air inlet to the fan. The hemispheric impeller shape and specially profiled blades increase the air flow circular velocity and provide higher pressure and capacity as compared to standard axial fans. The diffuser, the specially profiled impeller and the directing vanes at outlet from the fan casing distribute air flow in such a way as to attain the best combination of high performance, enhanced pressure and low noise. Inline mixed-flow fans with the air capacity up to 2350 m 3 /h Inline mixed-flow fans with the air capacity up to 450 m 3 /h Application The and fans are featured with wide capabilities and high performance of axial and centrifugal fans and are specifically designed for supply and exhaust ventilation of premises requiring high pressure, powerful air flow and low noise level. The fans are compatible with round air ducts from Ø 100 to 315 mm. Exhaust ventilation systems based on the TT fans are the best solution for ventilation of bathrooms and kitchens and other humid premises as well for ventilation of flats, cottages, shops, cafes, etc. Design The fan casing is made of high quality and durable materials: ABS plastic for the series or low-flammable polypropylene for the series. The removable impeller and motor block with a terminal box is fixed to the casing assembled with the spigots by means of special clamps with latches. This makes the fan maintenance fast and easy. The fan maintenance does not require total disassembling. Just pull out the central block from the casing and Motor The models of series are equipped with single-phase double-speed motors. Some dimension types are available with a more powerful motor ( S). The models of series are equipped with single-phased double-speed motors with low energy demand. The motors have thermal overheating protection to prevent the motor overload. The ball bearings extend the motor service life up to 40 000 hrs. at non-stop operation. The motor has IP X4 ingress protection rating. Designation key: Series Air duct diameter 100; 125; 150; 160; 200; ; 315 Options S high-powered motor; T timer; U electronic module with temperature-based operating logic and the temperature sensor integrated into the air duct; Un electronic module with temperature-based operating logic and the external temperature sensor; U1 electronic module with timer-based operating logic and the temperature sensor integrated into the air duct; U1n electronic module with timer-based operating logic and the external temperature sensor; P power cord with a plug; V three-position switch; P built-in speed controller.

WWW.VENTILATION-SYSTEM.COM Speed control in series mounting to increase operating pressure; external temperature sensor fixed on 4 m power cable (Un / U1n option). TT fan with a three-position speed switch The double-speed motors are controlled with a built-in switch (V option) or an external switch for multi-speed fans (available upon separate order). An integrated speed controller (option R), an external TRIAC or autotransformer speed controller (available upon separate order) are used for smooth speed control when connected to the maximum speed terminal. TT fan with a built-in speed controller Mounting The fans are suitable for mounting at any angle and point of the system. Several fans may be installed inside one system. Several fans may be installed inside one system: parallel mounting to increase air flow; TTP kit for parallel connection TTS kit for series connection The fan case is equipped with a flat mounting plate to attach the fan to the wall. The mounting box may be installed in any position to facilitate mounting and wiring. The fan with electronic module of the temperature sensor and speed controller (U option). The ideal solution for ventilation of the premises with high demands to permanent indoor temperature level, e.g. greenhouses. The fan with the electronic module of the temperature sensor and the speed controller is used for automatic speed control (air capacity regulation) depending on the air temperature in the ventilation duct or inside a room. The electronic module of the front panel incorporates: the speed control knob for the setting the impeller speed; the thermostat control knob for setting the temperature set point. thermostat LED light. Two modifications are possible: temperature sensor integrated inside a fan duct (U/U1 option); Operating logic of the fan with the electronic module of the temperature sensor and speed controller Set the desired air temperature (set point of the thermostat) with the thermostat control knob. Set the required minimum impeller speed (air flow) with the speed control knob. The motor switches to maximum speed (maximum air flow) as the temperature reaches and exceeds the set temperature set point. The motor switches to the pre-set speed as the temperature drops down below the set temperature point. To avoid the frequent motor switching, e.g. when the temperature in the supply air duct is equal to the threshold value, the switching delay time is activated. There are two switch delay patterns for various cases: 1. The temperature sensor-based switch delay (U option): the motor switches to higher speed as the air temperature exceeds 2 C above the set thermostat set point. The motor revers to the preset lower speed as the air temperature drops below the thermostat set point. This pattern is used to keep air temperature to within 2 C. In this case the fan switches are rare. 2. The timer-based switch delay (U1 option): as the air temperature exceeds the set thermostat set point, the motor switches to higher speed and the switch delay timer is activated for 5 min. The motor reverts to lower speed as the air temperature drops down below the thermostat set point and only after the timer countdown. This pattern is used for exact air temperature control. The fan changes its speed more often as compared to the temperature sensor-based switch delay, however the minimum timer interval is 5 minutes. 2

FANS FOR ROUND DUCTS Technical data: ТТ PRO 100 ТТ PRO 125 ТТ PRO 150 / ТТ PRO 160 Speed min. max. min. max. min. max. Voltage [V / 50 Hz] 1~ 230 1~ 230 1~ 230 Power [W] 23 25 25 30 42 50 Current [A] 0,10 0,11 0,11 0,13 0,19 0,22 Maximum air flow [m 3 /h] 162 210 234 330 415 565 RPM [min -1 ] 1980 2545 1535 2265 1940 2620 Noise level at 3 m [dba] 27 32 29 34 37 46 Maximum operating temperature [ о C] 60 60 60 Protection rating IP X4 IP X4 IP X4 LwA to inlet dba 47 23 21 37 41 44 42 37 27 L wa to outlet dba 48 24 24 38 42 45 38 38 26 LwA to environment dba 37 20 19 23 30 34 26 26 17 LwA to inlet dba 51 25 24 41 47 49 50 39 32 L wa to outlet dba 53 25 29 42 45 49 48 42 32 LwA to environment dba 39 21 24 28 32 40 33 28 20 LwA to inlet dba 54 36 34 40 45 51 48 41 25 L wa to outlet dba 64 39 40 55 57 58 63 56 44 LwA to environment dba 67 38 40 52 57 57 63 55 42 3

WWW.VENTILATION-SYSTEM.COM Technical data: ТТ PRO 200 ТТ PRO ТТ PRO 315 Speed min. max. min. max. min. max. Voltage [V / 50 Hz] 1~ 230 1~ 230 1~ 230 Power [W] 90 125 125 177 225 330 Current [A] 0,4 0,55 0,54 0,79 0,98 1,43 Maximum air flow [m 3 /h] 830 1040 1110 1400 1760 2350 RPM [min -1 ] 2045 2510 1955 2440 1980 2660 Noise level at 3 m [dba] 45 52 47 55 49 58 Maximum operating temperature [ о C] 60 60 60 Protection rating IP X4 IP X4 IP X4 LwA to inlet dba 75 51 51 60 69 69 76 66 57 LwA to outlet dba 76 53 58 60 67 69 72 67 56 L wa to environment dba 62 47 47 43 55 60 55 51 38 L wa to inlet dba 79 51 62 65 71 74 75 63 55 LwA to outlet dba 78 53 52 64 72 75 74 64 54 LwA to environment dba 68 47 48 48 60 62 54 49 34 LwA to inlet dba 82 55 53 66 75 82 80 67 58 LwA to outlet dba 84 57 58 69 78 80 78 67 57 L wa to environment dba 72 51 51 53 62 72 61 55 39 4

FANS FOR ROUND DUCTS Technical data: ТТ 100 ТТ 125 ТТ 125 S ТТ 150 / ТТ 160 Speed min max min max min max min max Voltage [V / 50 Hz] 1~ 230 1~ 230 1~ 230 1~ 230 Power [W] 21 33 23 37 28 54 30 60 Current [A] 0,11 0,21 0,18 0,27 0,12 0,16 0,17 0,27 Maximum air flow [m 3 /h] 145 187 220 280 240 320 405 520 RPM [min -1 ] 2180 2385 1950 2455 1850 2510 1680 2460 Noise level at 3 m [dba] 27 36 28 37 31 42 33 44 Maximum operating temperature [ о C] 60 60 60 60 Protection rating IP X4 IP X4 IP X4 IP X4 140 120 100 ТТ 125 80 60 40 max 20 min 0 0 40 80 120 160 200 240 280 LwA to inlet dba 53 26 23 41 46 50 47 41 31 L wa to outlet dba 54 27 27 43 47 50 42 42 29 LwA to environment dba 41 23 22 26 34 39 29 29 19 LwA to inlet dba 57 28 27 45 52 54 55 43 35 L wa to outlet dba 59 28 32 47 50 54 53 47 36 LwA to environment dba 43 23 27 31 36 44 37 31 22 200 ТТ 125 С 200 ТТ 150 ТТ 160 150 150 100 100 max max 50 50 min min 0 0 50 100 150 200 300 350 0 0 100 200 300 400 500 L wa to inlet dba 60 31 34 49 51 57 60 46 38 L wa to outlet dba 61 36 32 51 52 58 56 48 37 LwA to environment dba 50 27 29 36 41 46 37 33 28 L wa to inlet dba 69 38 40 57 60 58 69 55 45 L wa to outlet dba 68 42 44 58 61 62 64 55 45 LwA to environment dba 53 36 37 41 46 52 49 39 24 5

WWW.VENTILATION-SYSTEM.COM Fan overall dimensions: Dimensions [mm] Type D B H L Mass [kg] 167 190 246 1,4 ТТ 100 96 ТТ 125 123 167 190 246 1,4 ТТ 125 S 123 223 295 3,0 ТТ 150 146 223 295 3,0 ТТ 160 158 233 295 3,0 Dimensions [mm] Type B H L Mass [kg] 195,8 226 302,5 1,54 D ТТ PRO 100 97 ТТ PRO 125 123 195,6 226 258,5 1,51 ТТ PRO 150 148 220,1 247 289 2,1 ТТ PRO 160 158 220,1 247 289 2,2 ТТ PRO 200 199 239 261 295,5 6,4 ТТ PRO 247 287 323 383 8,3 ТТ PRO 315 310 362 408 445 11,4 TT fans applications bathroom ventilation example Parallel installation of fans in the storehouse to increase the air capacity office ventilation example

Inline mixed-flow fans / ventilation systems VENTS reserves the rights to modify any of its products features, designs, components and specifications at any time and without notice to maintain the development and quality of manufactured goods. 07/2012