BALANCED VENTILATION SYSTEMS

Similar documents
BETTER AIR. BETTER LIFE.

Indoor Air Quality Product Brochure.

Indoor Air Quality Product Brochure.

IT S ABOUT TIME FOR FRESH AIR.

Your complete source of information on Venmar AVS air exchangers. Constructo: 1.0 / 1.5 / 2.0 Solo: 1.5 / 2.0 Duo: 1.2 / 1.4 / 1.9 HE: 1.3 / 1.8 / 2.

Residential Balanced Ventilation Systems

50% 80% 7 Years. Filter. Ventilation Solutions IAQ Canada. Ventilate. of our time is spend indoors. Limited warranty on motors

Healthy Climate Indoor Air Quality Solutions. Solutions that fit your unique needs

Healthy Climate Indoor Air Quality Solutions. Solutions that fit your unique needs

Automatic Make-Up Air Damper

healthy comfort Indoor Air Quality Solutions

IAQ VENTILATION SOLUTIONS

Ventilation Solutions IAQ Canada

LIGHT COMMERCIAL Heat and Energy Recovery Ventilators

Indoor Air Quality FILL YOUR HOME WITH AIR THAT IS AS CLEAN AS IT IS COMFORTABLE.

healthy comfort Indoor Air Quality Solutions

IAQ VENTILATION SOLUTIONS

A whole lot of fresh.

Indoor Air Quality FILL YOUR HOME WITH AIR THAT IS AS CLEAN AS IT IS COMFORTABLE.

TR Series - The Ultimate ERV

Ventilation Solutions IAQ Canada

WE ARE CONTINUOUSLY ADDING TO AND IMPROVING OUR INDOOR AIR QUALITY PRODUCTS TO PROTECT YOUR FAMILY S HEALTH.

BROAN ERVS100 Part no. ERVS100S CFM (0.4 in. w.g.)

The PureAir system improves air quality throughout your home.

The PureAir system improves air quality throughout your home.

Put the V back in HVAC

Heating Products M arch 2012

Fresh Air Solutions Whole-Home Ventilation

Clean Air Solutions. A Complete Family of Indoor Air Quality Products, for the Protection of your Home and your Family.

HEALTH. Particles. Chemicals

PureAir Air Purification System PCO-12C/20C

Comfort Series. Energy Recovery Ventilator. Why Fresh Air Ventilation is Vital for Today s Energy-Efficient Homes

Residential Heat & Energy Recovery

Improving your home comfort by enhancing the air

Ultra SERIES. A revolution in ventilation fan technology

Ventilation has never been more important

Air Purity Solutions Whole-Home Air Purifiers

WALL CONTROLS MAIN CONTROLS

SMART ERV Energy Recovery Ventilator. Build It Tight / Ventilate It Right!

HEALTH. Particles. Chemicals

Temperature Relative Humidity

HRV / ERV. Heat or Energy Recovery Ventilation Systems. You need fresh air, so does your home.

Outside Air Requirements... SOLVED!

Home air-improvement options to suit your needs

HRV / ERV. Heat or Energy Recovery Ventilation Systems. You need fresh air, so does your home.

Range Hoods DESIGN FOR LIFE

Indoor Air Quality Test Report

Building Science Basics

Consumer Features & Benefits of Energy Efficient Products

Ultra SERIES. We ve Revolutionized the Ventilation Fan

Perfect Air Purifiers

Tech to Tech May 07 HRV s & ERV s

Clean Air Furnace. Finalist Canada s National Energy Efficiency Awards

The best way to enhance indoor air quality

Home WHOLE-HOME COMFORT SOLUTIONS. Bringing balance. Creating comfort.

HEAT RECOVERY AND ENERGY RECOVERY VENTILATORS

at the touch of a button.

Choosing an Air Cleaner

/BRO BuyLine 5694

Indoor Air Quality Fundamentals

Making Your Home Asthma Friendly

Simple solutions. for clean air and water. EnergyStar Partner of the Year. LOW. For more information, visit Lowes.com/HealthyHome

READ ONLY Trane XLi Heat Pumps. Total comfort, and Trane reliability, all year long.

PROOF. our story. insert pictures of things or people that tell the story. about your company

Managing HVAC in High Performance Buildings

HEALTHY CLIMATE Heat / Energy Recovery Ventilator

INDOOR AIR QUALITY PRODUCTS COMPLETE YOUR COMFORT WITH CLEANER, FRESHER INDOOR AIR

Home Performance Science

about your house Assessing the Comfort and Safety of Your Home s Mechanical Systems

WHAT YOU DON T SEE CAN HURT YOU. KenkoAir Purifier

MODELS TR & TRC TOTAL RECOVERY FOR ALL CLIMATES RESIDENTIAL OR COMMERCIAL APPLICATIONS

SmartVent. NZ's home ventilation specialists. Become the climate expert in your home. SMARTVENT HOME VENTILATION SYSTEMS

TECHNICAL SPECIFICATIONS

High Efficiency Air Cleaners

WHOLE-HOUSE VENTILATION SYSTEMS

Temperature Relative Humidity

Trane 95 and 90 Gas Furnaces. Innovative furnaces with efficiency in mind.

Condensation on Your Windows?

HEPASilent Air Purification Systems. Clean air is a human right

Welcome to a Healthy Home

Classic i series Intelligent air purifier

Featuring Vent Lights and Premium Grilles

HEAT RECOVERY VENTILATOR

InspirAIR Compact Heat and Energy Recovery. Multi-Family HRV/ERV

State of MN Energy Code Ventilation Review for 2017 Energy Design Conference. By 1. Mike D. Wilson Dakota Supply Group

Ventilation and Indoor Air Quality

FAN COILS MULTI-POISE, VERTICAL, AND HORIZONTAL MODELS

Clean air is a human right

Comfort, Energy & Health Solutions

INSTALLATION AND OPERATION MANUAL Model BR70/BR130

Model 1700 Whole-Home Dehumidifier

Bring Mountain Freshness Indoors

Humidity Solutions Whole-Home Dehumidifiers

The 2018 Ventilation Extravaganza. Rick Karg Residential Energy Dynamics 2018

Performance Series Indoor Air Quality Systems for Fan Coil Application

VENTILATION SOLUTIONS

Trane 95 and 90 Gas Furnaces. Innovative furnaces with efficiency in mind. READ ONLY

PA / PA-PRO PORTABLE AIR PURIFIER Instruction Manual

Overview and Specifications

10-year industry best core warranty. 5-year warranty on balance of unit.

Transcription:

BALANCED VENTILATION SYSTEMS

Know what you re breathing? Clear the air with simple solutions from Broan. Most are aware 90% of American homeowners realize that poor indoor air quality can contribute to certain health issues and that healthy air could help prevent illness. A majority (60%) of homeowners know that indoor air quality has a greater impact on their health than outdoor air quality. And haven t acted Less than half of Americans (46%) recognize that a lack of a bathroom fan has a negative impact on indoor air quality, and only 42% recognize that a lack of a range hood also has a negative impact. Only 61% of American homeowners have a range hood, and only 33% of that group uses it nearly every time they cook; only 27% keep it on for 10 minutes after they re done cooking. Nearly six in ten have a fan in each bathroom but only one in five keep it on for ten minutes after showering. Only 7% say that they change it when their mirrors start fogging up. 2

According to a national survey, homeowners are aware that INDOOR AIR QUALITY (IAQ) is an issue but they don t take appropriate measures to prevent airborne pollutants and improve the air they breathe. THE LEADER IN INDOOR AIR QUALITY But may not know Only two in five (42%) worry about moisture that could cause mold or mildew. Less than one-quarter (22%) actually worry about the poor air quality in their homes. They are much more concerned with bugs or intruders. These Broan products solve indoor air quality issues. Keep humidity levels in check. Only 33% of Americans know that the smell of food lasting in the home after it s been prepared is an indicator of poor IAQ. 81% don t know that a foggy mirror means poor IAQ. Clear the kitchen air. 41% of Americans say that their bathroom mirror fogs up when they shower. Strike some balance. 3

Today s tightly constructed homes seal in more than you think. Bedroom: Dust and dander on sheets and carpets, CO 2, odors, formaldehyde off-gassing, fumes from dry cleaning and other solvents Bathroom: Odors, CO 2, window condensation, mold and mildew, formaldehyde and aerosol fumes Living Room: Dust and dander on furniture and carpets, CO 2, carpet cleaning fumes and particles, fireplace smoke and ash and formaldehyde off-gassing Kitchen: Cooking pollutants, carbonmonoxide from gas cooktops, waste bin odors and cleaning chemical fumes Attic: Insulation fibers, construction dust and formaldehyde off-gassing Percent of Relative Humidity 0 10 20 30 40 50 60 70 80 90 100 Bacteria Viruses Allergic Rhinitis & Asthma Respiratory Infections Ozone Production Optimum Zone Bacteria Viruses Fungi Mites Allergic Rhinitis & Asthma Chemical Interactions In the optimum zone of 40 60% relative humidity you ll minimize problems. 4

Broan has ventilation options for every home and budget. Exhaust: Expel stale air automatically. Ventilation fans that once worked independently can now be coordinated in an economical, integrated system called Broan SmartSense. Balanced: Blend fresh outside air with indoor air. Step up to balanced ventilation to replace stale air with fresh, outside air. HEPA* + Balanced: Blend in fresh outside air and continuously filter. Our best solution filters microscopic particles as small as 0.3 microns from incoming fresh air and indoor air. For comparison, a human hair is 150 microns thick. Eliminating or minimizing sources of indoor air pollution. Awareness and information are the keys to better understanding indoor air quality. Eliminating smoking indoors, regularly cleaning and maintaining your HEPA* filtration equipment are good first steps to removing contaminants in your home. Local and Whole-house ventilation. Proper ventilation has two main components: Local ventilation removes pollutants at the source through locally operated bathroom fans and kitchen range hoods. Rapidly eliminating humidity and contaminants at the source lessens the possibility of dissipation throughout the home. Whole-house ventilation continually removes and dilutes pollutants not captured by local ventilation. This constant exchange of fresh air provides for a more healthy and comfortable home. Filter incoming outside air with a whole-house air cleaning system. Using a HEPA* filtration system with antimicrobial protection will lower the airborne concentration of dust, pollen and other particulates. HEPA* is different from electronic air cleaners that typically produce ozone, which itself is classified as a pollutant. And, portable air cleaners have been cited as ineffective by leading consumer safety organizations. Control indoor humidity. While humidity is not a pollutant, it can create a range of problems from health concerns to structural problems. Maintain indoor relative humidity between 40 to 60 percent to minimize mold, mildew and other possible hazards. *High Efficiency Particulate Air 5

Ventilate your home intelligently. Broan SmartSense and QT Series ventilation fans now work together. Broan QT Series Fan Select range hoods are available with our LinkLogic enabled residential communications system. Exhaust Vent Broan SmartSense Control Exhaust Vent 6 An economic alternative to other systems. Broan SmartSense utilizes exhaust ventilation fans normally installed in the home. It automatically adjusts total runtime based on square footage and number of bedrooms. Broan SmartSense controls monitor manual fan operation and adjust ventilation time to optimize energy usage. This system is more cost effective and energy efficient than other ventilation strategies that require the use of the home s air handler. With only one fan running at a time, Broan SmartSense uses less than 40 watts during ventilation cycles. Up to ten fans can be installed on one Broan SmartSense Ventilation System. Broan SmartSense is the smart choice to meet local and whole-house requirements of ASHRAE Standard 62.2* and other related guidelines (including building codes derived from the ASHRAE standard). * American Society of Heating, Refrigerating and Air-Conditioning Engineers standard for ventilation and acceptable indoor air quality for low-rise residential building. Why do I need to ventilate all day? Proper ventilation exhausts stale air and replaces it with fresh air. This minimizes mold and mildew growth, and helps remove gases and particles not trapped by filtration units. This automatic ventilation solution reduces indoor pollutants such as household cleaners, VOCs, carbon monoxide, off-gassing formaldehyde from building materials, carpets and other furnishings. Installs as easily as an exhaust fan. Simply recess the fan housing in the ceiling, vent with 6" duct to the outside and connect the power wires. No separate control wiring is necessary. Then, program the controls to match the size of the home. For tightly built homes. Consider using a Broan Make-up Air Damper to form a complete balanced ventilation system by linking with Broan SmartSense ventilation fans and/or select Best range hoods.

How does it work? The Broan SmartSense system monitors and activates Broan QT Series fans 24/7 throughout the home. Broan QT Series fans operate at a barely audible 0.3 and 0.7 sones, so they are ideal for any room that might require additional ventilation. Even in a bedroom, you ll never know they re running. One control monitors and manages the total run time of all SmartSense fans on the system. You choose which control is the master. Broan SmartSense uses LinkLogic, a powerful, wireless home control technology powered by INSTEON. It will interface with other LinkLogic enabled products by Broan or Best. Model CFM Dimension SSQTXE080 80 11-3/8 x 10-1/2 x 7-3/4 SSQTXE110 110 11-3/8 x 10-1/2 x 7-3/4 Broan SmartSense is the smart choice to meet local and whole-building ventilation requirements of green building programs such as Leadership in Energy Efficient Design (LEED), NAHB Green Building Guidelines and ENERGY STAR Indoor Air Package. Broan QT Series Fan Broan SmartSense Control Broan SmartSense Control Broan QT Series Fan Exhaust Vent Sizing your ventilator In order to select the proper unit, you need to look at the square footage and number of bedrooms in your home in order to get the right amount of airflow necessary. The following chart is based on the standards for ventilation and indoor air quality as stated in ASHRAE 62.2 Before specifying your Broan SmartSense system, check the local building codes to ensure it meets specific requirements. Number of Bedrooms < 1500 0 1 2 3 4 5 Broan Automatic Make-Up Air Dampers work with Broan SmartSense to enable efficient and effective home ventilation. The damper communicates with every SSQTXE080 and SSQTXE110 fan in the home to ensure a supply of fresh air is available while fans are being operated. This assists in maintaining a healthy air-pressure balance in the home while preventing unwanted air infiltration and wasted energy. Easy Installation of Broan Make-Up Air Dampers. Located in a 6-inch or 8-inch duct running between an exterior wall fresh air inlet (641FA or 643FA) to an interior location such as a cold-air return or supply duct. Damper is locally powered by a 24 VAC transformer. Damper and fans communicate over existing home electrical wiring. No additional interconnection required. Broan Make-Up Air Dampers feature: Heavy-duty galvanized steel construction. 24 VAC transformer. 6-inch round (SMD6), 8-inch round (SMD8). Use with any single fan or combination of SSQTXE080 or SSQTXE110 fans. Home Square Footage 1501 to 3000 3001 to 4500 4501 to 6000 30 CFM 45 CFM 60 CFM 45 CFM 60 CFM 75 CFM 60 CFM 75 CFM 90 CFM 75 CFM 90 CFM 105 CFM CFM requirements based on ASHRAE 62.2 continuous ventilation specifications 7

HRV or ERV? Learn how to select the best air exchanger for your home. HRV Heat Recovery Ventilators HRVs enable heat to be retained during cooler seasons, making it ideal for colder climates where home heating and energy savings are essential. The HRV keeps the home supplied with a steady flow of fresh outdoor air. As stale, warm air is expelled from inside the home through the HRV air exchanger, the heat recovery core warms incoming colder, fresh air before it is distributed throughout your home. The result is a constant supply of tempered fresh air, no unpleasant drafts and greater home comfort. The HRV not only improves heat retention during cooler seasons but also removes heat from warm outside air during warmer seasons to help reduce the workload on your furnace/air conditioner. By ensuring your home is ventilated with a steady flow of fresh, outdoor air at all times, the HRV system improves air quality resulting in greater comfort in your home. Where your home is geographically located will determine whether a Heat Recovery Ventilator (HRV) or Energy Recovery Ventilator (ERV) air exchanger is best suited for your environment. An HRV is ideal for colder climates while an ERV system provides year-round ventilation that is suitable for all climates. As incoming air enters the unit it is tempered as it passes through a heat exchanger. Stale indoor air is exhausted to the outside. The sealed heat exchanger does not mix fresh air with stale indoor air. Stale indoor air is routed to the heat exchanger to recover energy before being exhausted to the outside. Tempered fresh air may be directed to the HVAC air handler, or ducted directly to rooms in the home. Energy Recovery Ventilators (ERV) are suitable for all climates but are recommended for use in warmer climates where humidity is a factor. For HRV systems with HEPA filtration, see page 13. Areas close to the dotted line may be able to use either ERV or HRV products. Consult local codes prior to specifying. 8

ERV Energy Recovery Ventilators ERVs are suitable for all climates including those with hot, humid summers where homes are air conditioned and possibly dehumidified during multiple seasons of the year. Similar to the HRV, an ERV system recovers heat in the cold season but also recovers the energy trapped in moisture, greatly improving overall efficiency. In humid climates, where homes are airconditioned and outside air is more humid than inside, an ERV system limits the amount of moisture coming into the home. In dry climates and humidified homes where humidity levels are greater inside, ERV systems limit the amount of moisture expelled to maintain optimal comfort levels. The ERV air exchanging system improves recovery efficiency by recovering heat and retaining the energy trapped in moisture while also tempering your home with humidity-balanced fresh air. The result is better indoor air quality and comfort in your home. Depending on desired humidity levels, moisture in the air may be brought back into the home, or transferred to outgoing stale air. As incoming air enters the unit it is tempered as it passes through a heat exchanger. Stale indoor air is routed through the heat and moisture exchanger before being exhausted to the outside. Tempered, humidity-balanced fresh air may be directed to the HVAC air handler, or ducted directly to rooms in the home. Stale indoor air is exhausted to the outside. The sealed heat and moisture exchanger does not mix fresh air with stale indoor air. Heat Recovery Ventilators (HRV) are ideal in colder climates where heat must be retained. HRV Zone ERV Zone 9

Equalizing Indoor Air Pressure Although you may not realize, it is important not to neglect the impact of an unbalanced ventilation system. If an air exchange unit does not expel and intake equal amounts of air, a negative or positive imbalance can occur. Positive Air Pressure Pushes hot and/or humid air into walls and insulation; condensation can lead to mold, mildew and rot Heat escapes from inside the home as it is pushed through the walls to the exterior Negative Air Pressure Infiltration of unconditioned air increases risks of mold and higher energy costs Potential backdraft from combustion appliances such as gas water heaters Equal Air Pressure Supply airflow (CFM) is equal to stale air exhaust Balancing is required on all units unless specified otherwise ASHRAE Square Footage Chart In order to select the proper unit for your home, look at the square footage and number of bedrooms to make sure you will get the right amount of air flow necessary. The following chart is based on the standards for ventilation and indoor air quality as stated in ASHRAE 62.2. Before selecting your ERV or HRV, check with local codes as well to make sure your unit will meet all requirements in your area. Number of Bedrooms 0 1 2 3 4 5 Home Square Footage < 1500 1501 to 3000 3001 to 4500 4501 to 6000 30 CFM 45 CFM 60 CFM 45 CFM 60 CFM 75 CFM 60 CFM 75 CFM 90 CFM 75 CFM 90 CFM 105 CFM CFM requirements based on ASHRAE Standard 62.2 continuous ventilation specifications. 10

Types of Installations Any Broan unit can be easily integrated with an existing forced-air system (furnace) or can be installed independently using the fully ducted system installation. Homeowners will be satisfied with multiple air intake and air exhaust grilles that bring exceptional ventilation into every room; not just selected areas. Whatever the installation or ventilation requirements, Broan has the solution to ensure proper ventilation and better indoor air quality. Fully Ducted System Primarily for homes with radiant flooring, hot water or electric baseboard heating. Effective because unit captures pollutants at the source and distributes fresh air to living areas. Exhausted Ducted System For homes with forced air heating systems or air handlers. Effective because unit captures pollutants at the source. Simplified For homes with forced air heating systems or air handlers. Easy to install as unit uses existing furnace or air handler ducting. NOTE: Installation may differ from one unit or home to another. 11

ERV70S, ERV70T / HRV70SE, HRV70TE Significantly increase the quality of the air inside your home with the Broan HRV70 and ERV70 Series balanced ventilation solutions. These units are an ideal choice for homes, condominiums, apartments and other limited space applications that require up to 70 CFM of continuous ventilation. With its compact size and 4-inch horizontal and top ports, it can be installed in small spaces such as a closet or mechanical room above a hot water tank. These units are perfect for builders needing energy-efficient balanced ventilation solutions that won t have a significant impact on the budget. The HRV70SE and HRV70TE are ENERGY STAR qualified in Canada. Maximum square footage of homes by number of bedrooms Model 2 Bedrooms 3 Bedrooms 4 Bedrooms 5 Bedrooms 6 Bedrooms ENERGY STAR ERV70S 4,700 4,000 3,200 2,500 1,700 ERV70T 4,700 4,000 3,200 2,500 1,700 HRV70SE 4,700 4,000 3,200 2,500 1,700 HRV70TE 4,700 4,000 3,200 2,500 1,700 * Square footage based off of ASHRAE 62.2 continuous ventilation requirements. Consult local codes before installing. 12

ERV90HCS, ERV90HCT / HRV90HS, HRV90HT Limited space is no longer a reason to keep yourself from enjoying fresh, tempered air in your home. The ERV90 and HRV90 are powerful units with small footprints enabling you to install them basically anywhere in your home. These units are the ideal choice for homes, condominiums, apartments and other limited space applications that require up to 90 CFM of continuous ventilation. The high-pressure blower design eliminates the need to balance the unit in most installations. Integrated circuit logic in the motor along with intelligent flow dampers make these units easy to access, easy to maintain and very precise. The interchangeable core enables the unit to be upgraded from an HRV to an ERV, and vice versa, without additional mechanical adjustments. Maximum square footage of homes by number of bedrooms Model 2 Bedrooms 3 Bedrooms 4 Bedrooms 5 Bedrooms 6 Bedrooms ERV90HS >6,000 >6,000 >6,000 5,400 4,600 ERV90HT >6,000 >6,000 >6,000 5,400 4,600 HRV90HS >6,000 >6,000 5,800 5,100 4,300 HRV90HT >6,000 >6,000 5,800 5,100 4,300 * Square footage based off of ASHRAE 62.2 continuous ventilation requirements. Consult local codes before installing. 13

ERV100HC / HRV100H The ERV100 and HRV100 are perfect for a larger single-family size home that require up to 142 CFM. The ERV100 and HRV100 are perfect for larger single-family homes that require up to 142 CFM. You can ensure that the air within your home is being circulated and the pressure remains balanced. These units are durable, reliable and offer high performance that will be sure to add value and quality to any home. The easy-access side panel makes maintenance quick and convenient with the ability to remove all parts in five minutes or less. With the Broan ERV100 and HRV100, feel confident that the air quality in your home is fresh and clean. Maximum square footage of homes by number of bedrooms Model 2 Bedrooms 3 Bedrooms 4 Bedrooms 5 Bedrooms 6 Bedrooms ERV100HC >6,000 >6,000 >6,000 >6,000 >6,000 HRV100H >6,000 >6,000 >6,000 >6,000 >6,000 * Square footage based off of ASHRAE 62.2 continuous ventilation requirements. Consult local codes before installing. 14

ERVH100SE / HRVH100SE The ERVH100SE energy recovery ventilator and HRVH100SE heat recovery ventilator are equipped with a HEPA filter that removes 99.97% of allergens and other microscopic particles in the air. That significantly increases the quality of air inside your home and reduces symptoms of allergies, asthma and other respiratory problems. The Broan ERVH100SE and HRVH100SE have a cutting edge blower design enabling ultra-quiet operation which is barely audible at low speed (2.5 sones, equivalent to the sound of a standard refrigerator) while providing up to 100 CFM of continuous ventilation. Both the ERVH100SE and HRVH100SE are ENERGY STAR Certified in Canada, reducing annual energy consumption by 25% and resulting in estimated savings of $350 in annual energy costs when compared to previous ERV/HRV products with HEPA filtration. The HRVH100SE includes an LCD electronic wall control with 5 operational modes including auto, economic, continuous, re-circulate and turbo to allow for optimal performance in any installation. Maximum square footage of homes by number of bedrooms Model 2 Bedrooms 3 Bedrooms 4 Bedrooms 5 Bedrooms 6 Bedrooms ENERGY STAR ERVH100SE >6,000 >6,000 >6,000 5,500 4,700 HRVH100SE >6,000 >6,000 >6,000 5,500 4,700 * Square footage based off of ASHRAE 62.2 continuous ventilation requirements. Consult local codes before installing. HEPA HEPA (High Efficiency Particulate Air) filter traps 99.97% of allergens and other microscopic particles in the air. A HEPA filter will remove all particles that are 0.3 microns in size or larger. As a reference point, a human hair is approximately 60 to 150 microns in diameter and a grain of pollen is 5 microns. Approximately 90% of air pollutants are smaller than 10 microns. These lightweight particles stay in the air longer and are more likely for you to breathe in, leading to more potential respiratory issues for those with sensitivity to dust and allergens. The clean air that HEPA filters produce can result in improved health, especially for those that suffer from asthma and allergies. 15

ERV140TE / HRV150TE Among the most energy efficient ERVs and HRVs on the market. The Broan ERV140TE and HRV150TE have been designed to be two of the most ecofriendly air exchangers on the market. Their innovative design incorporates extremely high performance ECM motors, which enable operation at power levels equivalent to a compact fluorescent bulb (13.5 watts), significantly lowering energy costs. It surpasses energy-saving standards by nearly 250% while providing effective heat (HRV150TE) and energy (ERV140TE) recovery, ventilation and quiet operation. The ECM motor technology enables four different motor settings to accommodate ventilation requirements from 80 157 CFM for the HRV150TE, and 80 140 CFM for the ERV140TE. Both the ERV140TE and HRV150TE are ENERGY STAR Certified in Canada. Maximum square footage of homes by number of bedrooms Model 2 Bedrooms 3 Bedrooms 4 Bedrooms 5 Bedrooms 6 Bedrooms ENERGY STAR ERV140TE >6,000 >6,000 >6,000 >6,000 >6,000 HRV150TE >6,000 >6,000 >6,000 >6,000 >6,000 * Square footage based off of ASHRAE 62.2 continuous ventilation requirements. Consult local codes before installing. 16

ERV200HC / HRV200H The perfect solution for large dwellings. The Broan ERV200 and HRV200 are the most powerful balanced ventilation systems in the Broan line-up. Delivering up to 235 CFM, these units are ideal for larger homes. With the Broan ERV200 and HRV200, you can ensure that the air within your home is being circulated and the pressure remains balanced. Maximum square footage of homes by number of bedrooms Model 2 Bedrooms 3 Bedrooms 4 Bedrooms 5 Bedrooms 6 Bedrooms ERV200HC >6,000 >6,000 >6,000 >6,000 >6,000 HRV200H >6,000 >6,000 >6,000 >6,000 >6,000 * Square footage based off of ASHRAE 62.2 continuous ventilation requirements. Consult local codes before installing. 17

AE60 The cost-effective solution to dilute contaminants inside your home. The Broan AE60 is the perfect Whole-Home Air Exchanger for smaller homes and condominiums with a bathroom fan. This unit can be installed wherever it is convenient, or where ducting to individual rooms is simplified. With up to 185 CFM and continuous background ventilation of 30 55 CFM of fresh air, this exchanger is a cost-effective solution to dilute contaminants inside your home. 18

LIGHT COMMERCIAL (Special Order Only) Heat Recovery for small facilities up to 750 CFM Model HRV650 500 750 CFM Efficient centrifugal blower May be installed suspended by chains to minimize sound and vibration Side removes for easy maintenance access; all connections are on one side Helps meet ASHRAE 62.2 requirements Heat Recovery for larger facilities up to 1250 CFM Model HRV1150 700 1250 CFM Powerful centrifugal blower Side removes for easy maintenance access; all connections are on one side Helps meet ASHRAE 62.2 requirements Moisture Reduction and Heat Recovery in extreme environments Model HRV700 500 800 CFM Sealed centrifugal blower Engineered for use in high-humidity locations, such as hotel pool rooms Powdercoat finish resists chemicals found in corrosive environments Side removes for easy maintenance access; all connections are on one side Helps meet ASHRAE 62.2 requirements 19

Accessories Main Controls Roof/Wall Caps VT1W Central control with dehumidistat Off/low/high rocker switch VT2W Central control with dehumidistat Intermittent/low/ high pushbutton switch Maintenance light VT4W 20-minute/hour timer Off/low/high speed/intermittent VT5W Programmable electronic wall control with LCD display Four modes and filter function 643M For 3-1/4" x 10" or up to 6" round duct Built-in back draft damper and bird screen Steel baked black enamel finish 641 For 6" round duct Built-in back draft damper and bird screen Aluminum natural finish Optional Controls Dampers, Inlets and Outlets 59V/59W 60-minute delay timer Operates continuously or for any set period Available in Ivory (V) or White (W) Duct 61V/61W 15-minute delay timer Operates for any set period up to 15 minutes (non continuous on position) Available in Ivory (V) or White (W) DH100W Dehumidistat control Variable setting from 20 80% relative humidity Available in White (W) T24H Clock input: 120V, 60HZ Select ON/OFF times in 30 minute increments Manual ON/OFF override switch Fits single-gang box Output contacts: 15 Amp 1875 Watt Resistive 8 Amp inductive 1350 Watt Tungsten 1/2 HP motor VB20W 20-minute timer Remote, illuminated switch provides 20 minutes of high speed ventilation at the push of a button Switch is supplied mounted in a white single gange wall plate BD4 Pressure relief damper with wall cap and 4" collar BD6 Pressure relief damper with wall cap and 6" collar DT4C Non-insulated flexible duct 4" round, 25' long DT4W Insulated flexible duct 4" round, 25' long DT6C Non-insulated flexible duct 6" round, 25' long DT6W Insulated flexible duct 6" round, 25' long EH6 Exterior inlet/ outlet hood 6" 641FA For 6" round duct No backdraft damper Includes mesh screen Intended as air inlet Installation Kits and Filters 20 TYIK1 Tandem transition kits for HRV90HS For units 100 CFM or less ACCWMK Wall-mount bracket kit for ERV70/HRV70 ACCHEPARF Replacement HEPA filter for ERVH100SE/ HRVH100SE ACCHEPAPK Pre-filter kit for ERVH100SE/ HRVH100SE 643FA For 8 round duct Aluminum Without backdraft damper Includes mesh screen Intended as air inlet

Model AE60 Port Location Top or Side Duct Diameter Air Flow Power Consumption Height Width Length Weight Recovery Type Specifications Filtration Type ENERGY STAR Limited Warranty 6" 160-185 1.2 Amps 15" 12.25" 23" 40 lbs. Heat Aluminum Mesh 2 Years ERV70S Side 4" 35-70 0.5 Amps 16.313" 19.813" 15.625" 34 lbs. Energy Merv 6 2 Years ERV70T Top 4" 35-70 0.5 Amps 18.625" 15.438" 15.625" 34 lbs. Energy Merv 6 2 Years ERV90HCS Side 5" 45-99 1.3 Amps 12.81" 19.81" 22.56" 45 lbs. Energy ERV90HCT Top 5" 45-99 1.3 Amps 12.81" 19.81" 22.56" 45 lbs. Energy ERV100HC Side 6" 60-142 1.4 Amps 21.1" 13.25" 34.6" 65 lbs. Energy 30 ppi washable reticulated foam 2 Years 30 ppi washable reticulated foam 2 Years 30 ppi washable reticulated foam 2 Years ERV140TE Top 6" 40-140 1.3 Amps 24.56" 14.94" 18.25" 65 lbs. Energy Merv 7 2 Years ERV200HC Top or Side 6" 110-201 1.9 Amps 21.1" 13.25" 34.6" 73 lbs. Energy 30 ppi washable reticulated foam 2 Years ERVH100SE Side 5" 100 0.6 Amps 17.438" 39.375 11.875 47 lbs. Energy HEPA 2 Years HRV70SE Side 4" 35-70 0.5 Amps 16.313" 19.813" 15.625" 30 lbs. Heat Merv 6 2 Years HRV70TE Top 4" 35-70 0.5 Amps 18.625" 15.438" 15.625" 30 lbs. Heat Merv 6 2 Years HRV90HS Side 5" 45-96 1.3 Amps 13.25" 19.81" 22.56" 39 lbs. Heat HRV90HT Top 5" 45-96 1.3 Amps 13.25" 19.81" 22.56" 39 lbs. Heat HRV100H Side 6" 64-146 1.4 Amps 21.1" 13.25" 34.6" 65 lbs. Heat 30 ppi washable reticulated foam 2 Years 30 ppi washable reticulated foam 2 Years 30 ppi washable reticulated foam 2 Years HRV150TE Top 6" 40-157 1.3 Amps 24.56" 14.94" 18.25" 52.4 lbs. Heat Merv 9 2 Years HRV200H Top or Side 6" 108-235 1.9 Amps 13.25" 34.6" 73 lbs. Heat 30 ppi washable reticulated foam 2 Years HRV650 Side N/A 500-750 5.7 Amps 24.50" 28.12" 34.00" 148 lbs. Heat HRV700 Side N/A 500-800 2.5 Amps 37" 20.75" 47" 211 lbs. Heat HRV1150 Side N/A 1150 11.7 Amps 24.50" 41.24" 34.00" 186 lbs. Heat HRVH100SE Side 5" 50-104 0.6 Amps 17.423" 11.892" 39.442" 56 lbs. Heat HEPA 2 Years *Refer to ASHRAE Standard 62.1-2007 Ventilation for Acceptable Indoor Air Quality (Commercial and High-Rise) Control Compatibility Model Main Controls Optional Controls VT1W VT2W VT4W VT5W VB20W 59V/59W 61V/61W DH100W T24H AE60 ERV70 ERV90H ERV100HC ERV140TE ERV200HC ERVH100SE* GSHH3K GSEH3K HRV70 HRV90HT HRV100H HRV150TE HRV200H HRVH100SE* *Separate control is included with product and must be used exclusively with that model. Dot signifies that specific unit will work with the listed control. 21

22

23

VENTILATION FANS CHIMES TRASH COMPACTORS SOLAR-POWERED ATTIC VENTILATORS INTERCOMS BALANCED VENTILATION SYSTEMS Broan is America s leading brand of residential ventilation products including range hoods, ventilation fans, heater/fan/light combination units, Balanced Ventilation Systems, built-in heaters, whole-house fans, electric and solar-powered attic ventilators and trash compactors. RANGE HOODS IRONING CENTERS HEATERS NuTone is America s leading brand of residential built-in convenience products including door chimes, central vacuum systems, intercom systems, ceiling fans, home theater speakers, ironing centers and ventilation fans. CEILING FANS VENTILATION FAN/LIGHTS Make yours a Broan-NuTone home. CENTRAL VACUUMS Broan.com Broan-NuTone LLC, 926 W. State Street Hartford, WI 53027 800-558-1711 In Canada call 877-896-1119 America s Choice For Green Builders. Proud to be ENERGY STAR partners. 2015 Broan-NuTone LLC Printed in USA 04/15 99850845F 0 26715 18525 2