SAVOY. Model : Output:8kW Technical manual. to be saved by the user for future reference. Multifuel stove

Similar documents
LIMOUSIN. Wood stove. Model : Output : 10 kw. Technical manual. to be saved. by the user. for future reference.

CE EN13240 ENJOY YOUR STOVE SAFELY. Multifuel Cast Iron Stove INSTRUCTION MANUAL

Camargue. Model : Technical manual. Output : 10 kw. to be saved. by the user. for future reference. Wood stove NF EN 13240

LIMOUSIN. Multifuel stove. Model : DIN EN : Output : 10 kw. Technical manual to be saved by the user for future reference

TECHNICAL MANUAL. Multifuel Stove Model EW1MF. To be retained by the user for future reference. Serial Number. Document EW1MF 0209

SAVOY MK2 Model : Technical manual STAUB FONDERIE

MONTFORT. Wood stove. Model : Technical manual to be saved by the user for future reference. Output : 5 kw FR EN NL IT EN 13240

Monaco. model : Technical manual to be saved by the user for future reference. Output :6kW. Multifuel stove DIN EN :

Dovre 700CBW Cast Iron Wood Stove INSTALLATION INSTRUCTIONS 700G/1095

TECHNICAL MANUAL. Multifuel Stove Model MV1MF. To be retained by the user for future reference

TECHNICAL MANUAL. The Buxton. Multifuel Stove Model BX1MF. To be retained by the user for future reference

Oakdale. Multifuel Cast Iron Stove Model FB1MF. To be retained by the user for future reference Thank you for purchasing an ACR Heat Products stove

Ashdale. Multifuel Cast Iron Stove Model FB2MF. To be retained by the user for future reference Thank you for purchasing an ACR Heat Products stove

Birchdale. Multifuel Cast Iron Stove Model FB4MF. To be retained by the user for future reference Thank you for purchasing an ACR Heat Products stove

Oxford 5. Operation and Installation Manual. Version A 21/06/2017 (MZSOX5SMB) IMPORTANT

Novus. Multifuel Stove Model Novus. To be retained by the user for future reference. Thank you for purchasing an ACR Heat Products stove

Malvern II. Multifuel Stove Model MAL2MF. To be retained by the user for future reference Thank you for purchasing an ACR Heat Products stove

Neo. Multifuel Stove Model Neo 1 / Neo 3. To be retained by the user for future reference Thank you for purchasing an ACR Heat Products stove

Langdale. Woodburning Cast Iron Stove Model FB6WB. To be retained by the user for future reference

CHARNWOOD COUNTRY 6 FT

SAVOY MK2 ELEGANCE. Multifuel stove. Norm DIN EN : Model : Technical manual to be saved by the user for future reference

Montfort MK2. Wood burning stove BS EN Model : Nominal output : 4,8 kw. Technical manual. to be saved.

INSTALLATION AND OPERATION MANUAL

CHARNWOOD COUNTRY 8B WOODBURNER OPERATING INSTRUCTIONS

Stockton. Clean-burn stove. MODELS: 3 MF/4 Wood/4 MF/5 MF. Installation and Operating Instructions. For Use in Great Britain and Eire

charnwood country 4MKII Operating & Installation Instructions

THE MUCH WENLOCK. Operating Instructions for Freestanding Much Wenlock Stove with Boiler

Bourgogne. Ref Technical manual. to be saved. by the user. for future reference. Oil burning stove (NF EN 1) Description of the appliance

Page 1. Cube Ref:

THE SEVERN. Operating Instructions for Freestanding Severn Stove with Boiler

Monaco. Multi fuel stove BS EN Model : Technical manual. Nominal output : 5,9 kw (wood) 8,8 kw (solid mineral fuels) to be saved

Montfort MK2. Multifuel stove EN Model : Nominal output : 5 kw. Technical manual. to be saved. by the user. for future reference

View. High Output Boiler Stoves. Instructions for Use, Installation & Servicing. For use in GB & IE (Great Britain & Republic of Ireland).

Stockton. High Output Boiler Stoves. Instructions for Use, Installation & Servicing. For use in GB & IE (Great Britain & Republic of Ireland).

Instruction Manual: Le Jurassien Ref 3701

Esse B MODEL Roomheater with boiler WOOD BURNING ONLY MODEL

Instructions for Use, Installation & Servicing

Stockton. High Output Boiler Stoves. Instructions for Use, Installation & Servicing. For use in GB & IE (Great Britain & Republic of Ireland).

Firefox 12B (Boiler Model) CE V.11

Riva F40 Cube. Multi-Fuel Free Standing Stove. Installation Instructions. Models: RVF40C. For use in Great Britain and Eire IMPORTANT

charnwood Operating & Installation Instructions

H E R A L D 8 0 B. Installation and Operating Instructions

THERMALUX SOLID FUEL SLOW COMBUSTION COOKERS AND BOILERS

Troubleshooting Guide

View 7 Inset. High Output Boiler Inset. Instructions for Use, Installation & Servicing. For use in GB & IE (Great Britain & Republic of Ireland).

Website:

Firebird Smoke Exempt Inset Stove

Stockton 7 & 8 Inset Convector Stove

Elise. Inset Convector Range. Instructions for Use, Installation & Servicing. For use in GB & IE (Great Britain & Republic of Ireland).

charnwood Operating & Installation Instructions

Yeoman CL. High Output Boiler Stove YM-CL8HB. Instructions for Use, Installation and Servicing

Stockton 7 Inset. High Output Boiler Inset. Instructions for Use, Installation & Servicing. For use in GB & IE (Great Britain & Republic of Ireland).

Oscar Solid Fuel Stove

USER S MANUAL, MAINTENANCE MANUAL INSTALLATION INSTRUCTIONS

View. Freestanding Stove Range. Instructions for Use, Installation & Servicing. For use in GB & IE (Great Britain & Republic of Ireland).

Elmdale Wychwood. Woodburning Stove Model FB5BK 10 YEAR 10 YEAR. To be retained by the user for future reference. Serial Number:

Free Standing Stove. Technical Manual. 8 Series. User and Installation Instructions. For use in GB & IE (Great Britain and Republic of Ireland).

FM5 Freestanding Multifuel Dry Stove

Mendip 5 standard and pedestal stove Multi-Fuel, Wood, Smoke control model 4.8 kw / 5.2kW Space Heating Stove

WOLVERTON STOVES U S E R M A N U A L S h A N d o N / A R d L E i g h

Ludlow Non-Boiler (Multi-Fuel)

VEGA 100 CLEAN BURN II INSTALLATION AND OPERATING INSTRUCTIONS (to be left with the householder)

View. Freestanding Stove Range. Instructions for Use, Installation & Servicing. For use in GB & IE (Great Britain & Republic of Ireland).

Little Wenlock Classic

H E R A L D 1 4 C E V. I I

Marvic. multifuel. English

C O N S O R T 9. Installation and Operating Instructions

Varde Aura. Smoke Control Kit. Additional Installation and User Instructions for use in Smoke Control Areas

charnwood Operating & Installation Instructions

Newton Multi Fuel 8kW Space Heating Stove With Boiler

Little Wenlock Solid Fuel Stove

Petit Godin 3720A, 3726, 3727, 3721A

Course introduction 2. 1 Appliances and fuels 3. 2 Combustion Legislation Air supply Flues and chimneys Commissioning 83

General instructions for the Installation and use of wood-burning stoves

Vogue. Wood Burning & Multi-Fuel Freestanding Stove Range. Instructions for Use, Installation & Servicing

Newton Multi Fuel 5kW Space Heating Stove

Installation Instructions. Rayburn 300W Wood Burning Cooker

Studio. Freestanding Cassette Range. Instructions for Use. For use in AU & NZ (Australia and New Zealand)

Varde Shape. Smoke Control Kit. Additional Installation and User Instructions for use in Smoke Control Areas

Kensal 20/33/40/40SL/60

High Output Boiler Stoves

Riva. Woodburning & Multi-fuel* Cassette Range. * Multi-fuel when fitted with a Multi-fuel grate. Instructions for Use, Installation & Servicing

Yeoman CL. Free Standing Stove Range. Instructions for Use, Installation & Servicing. For use in GB & IE (Great Britain & Republic of Ireland).

Aresta, Limit & Firepoint

WOOD STOVE SERVICE MANUAL

Part 1: Installation Instructions for WAGENER SPARKY (Please keep these Instructions for future Reference)

Yeoman CL7. Inset Convector Stove. Instructions for Use, Installation & Servicing. For use in GB & IE (Great Britain & Republic of Ireland).

ESSE Cooking Stove OPERATING & INSTALLATION INSTRUCTIONS MODEL: EW/EWB GUARANTEE INFORMATION FOR USE WHEN ORDERING SPARES: 01/06.

Nectre Inbuilt LE. Operating Instructions. Efficient Warm Friendly. Keep instructions in a safe place for future reference.

Technical Specifications Panoramic FX1

Stockton Double. Freestanding Stove Range. Instructions for Use, Installation & Servicing. For use in GB & IE (Great Britain & Republic of Ireland).

Yeoman CL7. Inset Convector Stove. Instructions for Use, Installation & Servicing. For use in GB & IE (Great Britain & Republic of Ireland).

HIGHLANDER Wood and Multi-fuel Stoves

SAEY 92 (TOP) WOOD/COAL

High Output Boiler Stoves

Operation instructions

Huntingdon. Freestanding Stove Range. Instructions for Use, Installation & Servicing. For use in GB & IE (Great Britain & Republic of Ireland).

Riva. Multi-fuel Cassette. Instructions for Use, Installation & Servicing. For use in GB & IE (Great Britain & Republic of Ireland).

Part 1: Installation Instructions for WAGENER LEON- Multi Fuel

MUCH WENLOCK CLASSIC NON-BOILER SOLID FUEL STOVE

Transcription:

SAVOY Document n 986-1 ~ 02/07/1999 Multifuel stove Model : 134 08 05 Output:8kW Technical manual to be saved by the user for future reference Description of the appliance Installation instructions Operating instructions Spare parts Warranty certificate Fonderies FRANCO-BELGES 59660 MERVILLE Phone : 03.28.43.43.43 Fax : 03.28.43.43.99 RC Hazebrouck 445750565B Subject to modifications

Multifuel stove "SAVOY" Réf. : 134 08 05 CONTENTS Page Product information..................... 3 Package.............................. 3 Optional.............................. 3 General characteristics...................... 3 Description............................ 3 Principle of operation....................... 3 Installation instructions.................. 4 The room............................. 4 Flue................................ 4 Connection to flue........................ 4 Assembly of flue spigot and blanking plates.......... 5 Door closing pressure...................... 6 Mounting the tray......................... 6 Chimney maintenance and sweeping.............. 6 Instructions for user.................... 7 Fuel................................ 7 Lighting.............................. 8 Re-fuelling............................. 8 Cleaning.............................. 8 Maintenance of the stove body................. 8 Trouble Shooting......................... 9 Spare parts......................... 11 2 Document n 986-1 ~ 02/07/1999 Technical manual

Réf. : 134 08 05 "SAVOY" Multifuel stove WARNING The appliance must be installed in compliance with Current Building Regulations. Incorrectly installed, this appliance can be dangerous and possibly cause serious accidents. The manufacturer s responsibility shall be limited to the supply of the equipment. 1. Product information 1.1. Package - 1 package : Stove complete. 1.2. Optional Boiler 1.3. General characteristics Reference... 1340805 Maximumoutput...kW 8 Chimney draft required........... Pa 10 Grate dimensions -width...mm 450 -depth...mm 240 - usable height................ mm 365 Log dimensions -Length... cm 40 -Diameter... cm 10à16 Ash pan capacity............. litres 3 Netweight... kg 100 Volumeheated... m 3 300 Autonomy... h 10 1.4. Description Multifuel stove. Fuel burnt on grate. Removable appliance, to be installed near a wall. Detachable flue spigot for rear or top chimney connection. Detachable top for easy handling and cleaning (rear smoke exit only). Adjustable air controls for controlling the burning rate. Spin wheel for lighting. Large ash-pan. 1.5. Principle of operation The Savoy is designed for operation with the door closed. Heat is mainly diffused by radiation, through the window and body of the appliance. Combustion occurs on the grate, with draught entry through the top of the combustion chamber when using wood or coal. 360 134 Ø139 535 Ø125 660 Figure 1 - Dimensions in mm 520 409 Technical manual Document n 986-1 ~ 02/07/1999 3

Multifuel stove "SAVOY" Réf. : 134 08 05 2. Installation instructions 2.1. The room Ventilation : For satisfactory operation with a natural draught, check that sufficient air for combustion is available in the room. Chimney position : For new chimney installations, select a central position within the building, to provide a good heat distribution around the building. Hearth : The hearth must be suitable for use with solid fuel burning appliances and must comply with Current Building Regulations. If in doubt, consult your Dealer or local Building Inspector. Rear wall and ceiling : The appliance must not be positioned close to combustible materials, wall & ceiling surfaces etc., Consult your Dealer or local Building Inspector if in doubt. - Pipe diameter must not be less than the appliance spigot diameter. - The connection can be either vertical or horizontal. For horizontal connections, avoid right angle bends. - The join between the connection pipe and the stovepipe, and the flue, must be leak tight. - The connection pipe and any draught stabiliser must have access for cleaning. 2.2. Flue Existing flue : - The flue must be in good condition and must provide sufficient draught. - The flue must be suitable for the installation of solid fuel burning appliances and comply with Current Building Regulations. - The flue must be clean. It should be swept to remove soot and dislodge tar deposits. - The flue must be well insulated. If the flue inner wall surfaces are cold, a good thermal draw is impossible causing condensation problems (tar formation etc.) to occur. - The flue must not be shared with other appliances. - The recommended minimum flue height is 5 meters. - If the chimney has any down draught tendency, due to its position in relation to nearby obstacles, then an anti-down draught cowl must be installed on the chimney or the chimney height must be increased. - If the decompression in the chimney is excessive, a draught stabiliser must be installed. Chimney to be built / Flue non-existent : - The flue must not be supported by the stove. - Consult a chimney specialist for advice on suitable flue systems for solid fuel appliances. 2.3. Connection to flue - The stove must be installed as close as possible to the chimney. - The stove should be connected to the flue by a smoke pipe, approved for installation with combustion products (e.g. stainless steel 1 mm thick, 20g, or vitreous enamel.). 4 Document n 986-1 ~ 02/07/1999 Technical manual

Réf. : 134 08 05 "SAVOY" Multifuel stove # "! Figure 2 - Flue outlet on the top 1 - Flue collar 2 - Ceramic rope 3 - Blanking plate 4 -Clamp 5- Top plate 2.4. Assembly of flue spigot and blanking plates Figure 3 - Rear heat shield The stove is supplied with a connection flue spigot with an inner diameter of 125 mm and an outer diameter of 139 mm. 2.4.1. Flue outlet on the top Figure 2 Remove the top plate. Fit the sealing rope 2 inthegrooveonthetopandfix thefluecollar1with 3 bolts and washers supplied. Replace the top plate. #! 2.4.2. Flue outlet at rear Figure 4 Remove the top plate. Remove the rear heat shield and remove the cut-out on it (fig. 3). Remove the retainer fuel (fig. 7, p. 6), the two side bricks # 23 and 24 p. 10) and the flue baffle (fig. 8, p. 6). Removetheblankingplate3and the clamp 4 and assembly in the top, ensuring there is a good seal. Fix the flue collar 1 at rear with 3 bolts and washers supplied, ensuring there is a good seal. Remove the cut-out in the rear heat shield and re-fit. Replace top plate. " Figure 4 - Rear flue outlet 1 - Flue collar 4 -Clamp 2 - Ceramic rope 5- Top plate 3 - Blanking plate Technical manual Document n 986-1 ~ 02/07/1999 5

Multifuel stove "SAVOY" Réf. : 134 08 05 A Figure 5 - Mounting the tray 1 2 Figure 8 - Removing the flue baffle 2.6. Mounting the tray 2.5. Door closing pressure Figure 6 Figure 6 - Door closing pressure The closing latch rotates around a pressure screw positioned cam. - Remove gently the ceramics rope - Loosen pressure screw 1. - Turn cam 2 to desired position. - Tighten pressure screw 1. To avoid damage during transport, the tray has been stored behind the main door. - Fixed the tray, of the appliance (ill. 5). Center on tab A and lower into place. 2.7. Chimney maintenance and sweeping Very important : To avoid accidents (chimney fire, etc.), regular maintenance should be carried out. If the stove is regularly used, the chimney should be swept several times per year, together with the stove pipe connection section. First remove the retainer grate (fig. 7), the two side bricks (# 23 & 24, p. 10) and the flue baffle (fig. 8) Chimney condition should be checked at least once per year. Figure 7 - Removing the fuel retainer 6 Document n 986-1 ~ 02/07/1999 Technical manual

Réf. : 134 08 05 "SAVOY" Multifuel stove E B B1 B2 A C C1 C2 F C3 G Figure 9 - Operating devices A:Door lock B:Draught control B1 = flap opened B2 = flap closed C:Spin wheel for lighting C1 = wheel opened 3. Instructions for user C2 = wheel closed C3 = de-ashing access E:Tool F : Poker G : Ash tray Don t run the stove in mild weather with coal : Under certain circumstances (e.g. fog and repeated thaw) the chimney will not draw sufficiently well and thus be at the origin of asphyxia. Awaiting better weather circumstances, don t use any coal but only wood. Warning : properly installed and operated this appliance will not emit fumes into the dwelling. Occasional fumes from de-ashing and re-fuelling may occur. Persistent fume emission is dangerous and must not be tolerated. If fume emission does persist : - Open doors and windows to ventilate room - Let the fire out and dispose of fuel from the appliance - Check for flue or chimney blockage, and clean if required Do not attempt to relight the fire until the cause of the fume emission has been identified and corrected. If necessary seek expert advice. Note : It is recommended to use a fireguard in the presence of children, and also in the presence of old and/or infirm people. 3.1. Fuel Recommended fuel :The best fuels for use with the Franco Belge Savoy are : Smokeless fuels, including coolite nuts, phurnacite, ancit, extracite and pureheat - Sunbrite (Small) - Anthracite (Medium) DryWood.-Usehardwoodlogswhichhavebeencut for at least two years and stored under shelter. - Hardwood has a higher calorific value per cu metre (oak, ash, maple, birch, elm, beech, etc.). Prohibited fuel : Homefire and any form of bituminous coal or petroleum based coke. Green wood. Green or damp wood reduces stove efficiency and makes the window, the internal walls and the flue dirty (soot, tar, etc.). Used timbers. Burning treated wood (railway sleepers, telegraph poles, offcuts of plywood or chip board, pallets, etc.) quickly clogs the flue ways (soot, tar, etc.), pollutes the environment (pollution and smell, etc.) and cause the fire to burn too quickly and overheat. Green wood and recovered wood can cause a chimney fire. Technical manual Document n 986-1 ~ 02/07/1999 7

Multifuel stove "SAVOY" Réf. : 134 08 05 3.2. Lighting Figure 9 - Slide the top air control (# B1) to the right. Open the lower spin wheel (# C1). - Lay firelighters or rolled up newspapers on the grate with a reasonable quantity, if necessary, of dry kindling wood. Place 2 or 3 small logs on top. - Light the newspaper or firelighters using a long taper and close the door (# A). - When the fire is burning fiercely, add further logs of a diameter up to 10 cms. - When the stove body is very hot, close the lower spin wheel (# C2). The burning rate can now be adjusted by moving the top air control to the left (# B1). Experience will show you which settings are best for your situation. Note : When the fire is lit for the first time, the stove may give off fumes from the new paint. This is normal but ensure the room is well ventilated during the first few hours of operation. 3.3. Re-fuelling It is advisable to wait for the fire to be reduced to hot embers before re-loading. The door should also be opened slowly when re-loading. 3.4. Cleaning It is essential to keep the grate free from a heavy build up of ashes. REMEMBER TO BURN SOLID FUEL CORRECTLY, AIR SHOULD BE ALLOWED TO FLOW FROM THE ASH PIT AREA THROUGH THE GRATE AND THROUGH THE FUEL. IF THE GRATE OR ASH PAN ARE CONGESTED, THE PERFORMANCE WILL BE EFFECTED. If burning solid fuel, always empty the ash pan at least once a day or whenever it is full of ashes. Never allow the ashpan to overfill allowing ash to be in contact with the underside of the grate. If this condition is allowed, the grate will wear out pre-maturely. 3.5. Maintenance of the stove body The stove must be regularly cleaned. Remove all deposits from the combustion chamber and clean the grate area. The vitro ceramic glass can only be cleaned using a soft cloth and stove glass cleaner, available from your Franco Belge Dealer. DO NOT USE ABRASIVES The vitro ceramic glass resists a temperature of 750 C. If the glass should be broken, it is recommended that only an original factory replacement should be fitted. For enamelled finishes, the stove body can be cleaned using a soft cloth either dry, or slightly damp with a very mild detergent. NEVER CLEAN ENAMEL SURFACES WHILST THE STOVEISHOT. The cast iron body panels of non-enamelled stoves can be cleaned with a proprietary stove cleaner or re-sprayed / touched up using a stove paint. These products are available from your Franco Belge Dealer. 8 Document n 986-1 ~ 02/07/1999 Technical manual

Réf. : 134 08 05 "SAVOY" Multifuel stove 3.6. Trouble Shooting Problem Probable causes Action þ : This sign means that you should asked for a qualified engineer to do the work. Fire difficult to start Fire goes out Wood green, too damp or poor quality. Logs are too big. Air starvation. - Use the recommended fuel. - To light the fire, use small, very dry twigs. To maintain the fire, use split logs. - Open lower spin wheel and top air control lever. Insufficient draught. þ - Check that the flue is not obstructed, sweep it if necessary - Seek advice from a chimney specialist. Fire burns too quickly. Too much draught. - Ensure that the lower spin wheel is closed - Partially close the top air control lever. Excessive draw. þ - Install a draught stabiliser. Consult your Dealer. Poor quality wood. - Do not continuously burn small wood, sticks, bundles, carpentry offcuts (plywood, pallets), etc. Smokes when lighting up. Flue duct is cold. - Burn paper and kindling wood to increase heat. Room is in decompression. - In houses equipped with mechanical ventilation, partly open a window until the fire is well established. Smokes while burning. Draught is insufficient. þ - Consult a chimney specialist. - Check that the flue is not obstructed, sweep if necessary. Down draught. þ - Install an anti-down draught cowl. Consult your Dealer. Room is in decompression. þ - In houses equipped with Mechanical Ventilation, an outside air intake must be installed for the chimney. Low heat output. Incorrect Fuels. - Use the recommended fuel. Technical manual Document n 986-1 ~ 02/07/1999 9

Multifuel stove "SAVOY" Réf. : 134 08 05 40 35 21 8 12 38 30 2 36 14 2 8 22 31 13 32 23 16 25 11 1 8 9 15 5 26 32 4 3 19 3 27 20 6 10 34 17 33 24 28 17 18 29 37 17 7 17 39 10 Document n 986-1 ~ 02/07/1999 Technical manual

Réf. : 134 08 05 "SAVOY" Multifuel stove 4. Spare parts When ordering spare parts, specify the stove type and serial number, including the colour index (on the guarantee or identification plate), the name of the part and the part number. Example : Wood stove, réf. 134 08 05, colour ref. : Y, top plate 352150 EF. N Code Description...Type...Qty 1 100917 Campin...12x20M7...01 2 100939 Axle...02 3 110404 Hingepin...6x30...02 4 134253 Bushing...01 5 142301 Adhesiverope...1,30m 6 166003 Spring...11x15...01 7 808001 60 Handtool...01 8 181607 Ceramicrope...Ø9,5...2,50m 9 188812 Ceramicglass... 379x293x4...01 10 189103 Screw... 27x8x6...01 11 189825 Screw...HCM5x6...01 12 205362 Backpanel...01 13 222556 Fluebaffle...01 14 237411 EF Reducingplate...01 15 259015 Fixingplate...04 16 270408 Aircontrolflap...01 17 300127 EF Leg...04 18 300481 EF Base...01 19 301526 EF Doorlock...01 20 301742 EF Airdamper...01 21 303718 EF Blankingplate...01 22 303860 EF Fluecollar...01 23 305014 Wall...01 24 305212 Wall...01 25 306276 EF Backwall...01 26 307434 EF Fuelretainer...01 27 308711 Coalgrate...01 28 309891 EF Frontplate...01 29 310726 EF R.sidepanel...01 30 310824 EF L.sidepanel...01 31 315607 Airduct...01 32 325304 Reducingplate...02 33 327903 EF Ash-tray...01 34 331104 EF Maindoor...01 35 352150 EF Topplate...01 36 406816 Clamp...01 37 624042 Ash-pan...01 38 162573 Descriptiveplate...01 39 415504 60 Poker...01 40 181619 Ceramicrope...Ø12...1,60m Technical manual Document n 986-1 ~ 02/07/1999 11

Warranty certificate Legal warranty Our products are guaranteed for twelve months against any defect, flaw or imperfection. During this time, all parts judged defective by our Warranty control department may be replaced in our workshops. Incidental costs of transportation and packing payable by the buyer. Some parts or components have a longer warranty period : - Cast-iron shell of boiler : 3 years - Steel shell of boiler : 3 years - Removable or independent stainless steel hot water cylinder : 5 years - Independent enamelled steel hot water cylinder : 3 years - Incorporated circulating pump : 2 years. Terms of the warranty This warranty is only valid if : - The unit has been installed and checked by a professional installer before operating, - All installation and adjustment instructions listed in the technical manual supplied with the unit have been followed, - All operation and maintenance instructions have been followed. This warranty does not cover : - Lamps, fuses, spark plugs, cast iron parts directly in contact with burning coal and wood, firebricks, glasses. - Any damage resulting from the use of fuel not recommended in our instructions ; - Parts which are damaged by external causes such as unadapted chimneys, thunderstorms, damp, faulty pressure or fail in pressure, thermic anomalies, explosions, etc... - Electrical parts which are deteriorated by any connection or use on a supply circuit with voltage within 10% of the indicted voltage (230 V). Material subject to modifications without prior notice. This manual does not engage the responsability of FRANCO BELGE. * Installer : Name and address ( Telephone : * Customer : Name and address Date of installation : Model of the appliance : 134 08 05 Color : Y Serial number : This certificate has to be completed and kept carefully. Document n 986-1 ~ 02/07/1999 In case of claims, send a copy of this to : Les Fonderies Franco-Belges, rue Orphée Variscotte, 59660 MERVILLE, FRANCE.